A19_Malmstrom Dorm 742-Bid Addendum 1.pdf

PDF 5 MB Posted

Attached to
Repair and Renovate Dorm 742
Solicitation number
FA4626-26-R-0009
Issued by

About this file

These are architectural drawings for the Repair of Dormitory 742 at Malmstrom Air Force Base in Great Falls, Montana, prepared for the 341st Missile Wing Civil Engineering Squadron. The documents comprise floor plans, reflected ceiling plans, and interior finish plans for Levels 01-03 of the dormitory.

The project involves renovation of residential suite spaces organized into three suite type categories (A, B, C) with varying layouts. Each floor contains multiple individual living units with rooms, closets, dining areas, kitchens, and bathrooms, along with common areas including laundry facilities, TV/lounge spaces, janitor closets, electrical rooms, mechanical rooms, personal storage, lobbies, corridors, and stairs. Interior finishes are specified across all spaces, including flooring materials (CPT-2 carpet, LVT-1 luxury vinyl tile, TIL-1 ceramic tile, RSF-1 resilient sheet flooring), wall bases (RWB-1 rubber wall base, TWB-1 tile wall base, RWB-2, INT-1), and paint colors (PNT-1 through PNT-4, with varying sheen finishes). Bathroom accessories include toilet paper holders, towel bars, and shower rods installed at specified heights. Reflected ceiling plans indicate 2'x2' acoustic ceiling tiles, new gypsum ceilings, 24"x24" and 48"x24" light fixtures, downlights, slot diffusers, and HVAC supply/return diffusers. All construction must comply with fire and life safety plans referenced in F-series drawings, with contractors required to verify existing conditions in the field and submit RFIs for any dimensions not clearly detailed.

View the file

Other files

Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REF. REF.

REF.REF. REF.REF.

REF. REF.

VFDVFD

FLOOR PLAN GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

REFER TO ENLARGED PLANS FOR NEW PARTITION TYPES AND LOCATIONS, AND FOR DOOR NUMBERS OF DOORS NOT

LABELED ON OVERALL PLANS.

CONTRACTOR TO VERIFY ALL EXISTING OPENING DIMENSIONS (DOOR, WINDOW, LOUVERS, ETC) IN THE FIELD.

SUITES TYPES ARE GROUPED (A,B,C) BASED ON GENERAL SIMILARITES OF THE LAYOUTS BETWEEN SUITES. CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD FOR EACH ROOM AS THE EXISTING CONDITIONS OF EACH SUITE TYPE MAY VARY.

FOR FIRE AND LIFE SAFETY PLANS, REFER TO F- DRAWINGS.

REFER TO A2 SERIES DRAWINGS, EXTERIOR ELEVATIONS, A3 BUILDING AND WALL SECTIONS.

REFER TO A6 SERIES FOR ALL PARTITIONS, DOORS, WINDOWS, AND ACCESSORIES.

REFER TO I-SHEETS FOR INTERIOR FINISHES.

REFER TO IG SERIES FOR INTERIOR SIGNAGE.

INSTALL BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED DEVICES.

GENERAL DIMENSIONS PROVIDED ON FLOOR PLANS AND AREA PLANS DO NOT REFLECT THE ROUGH OPENING DIMENSIONS REQUIRED FOR COORDINATION WITH MASONRY JOINT COURSING. CONTRACTOR IS TO PROVIDE ROUGH OPENING FRAMING DIMENSIONS CONSISTENT WITH ENLARGED ARCHITECTURAL PLAN/SECTION DETAILS (A5 SERIES SHEETS), AND WINDOW SCHEDULE/DETAILS (A6 SERIES). CONTRACTOR TO SUBMIT RFI FOR ANY ROUGH OPENING DIMENSIONS NOT GIVEN IN

DETAILING FOR CLARIFICATION REQUIRED.

REFER TO "TYPICAL SUITE PLANS AND ELEVATIONS" SHEETS FOR ENLARGED PLANS, RCPS, AND INTERIOR ELVATIONS OF

TYPICAL SUITES.

SUITE PLAN SHOWN AS A REFERENCE TO IDENTIFY THE LOCATION OF EACH SUITE ON EACH FLOOR

PROVIDE NEW GUARDRAILS AND RAILINGS AT ALL STAIRS.

SUITE BATHROOM ACCESSORIES INCLUDE (1) TOILET PAPER HOLDER, (2) TOWEL BARS AND (1) SHOWER ROD. REFER TO

G-001 FOR TYPICAL MOUNTING HEIGHTS OF ACCESSORIES, UNO.

A-201

H1

A-201

A-201

A-201 D1

H7

A1

A

2 3 4 5 6 7 9 11 13 14 15 16 17 18 19

B

C

D

8 10 12

A-401 A2

DINING

120C

120A

ROOM

B-2

120B

CLOSET

B-2

KITCHEN

120D

BATHROOM

120E

118A

ROOM

B-1

118B

CLOSET

B-1

118C

CLOSET

B-1

116C

CLOSET

A-2

116A

ROOM

A-2

116B

CLOSET

A-2

KITCHEN

114D

DINING

114C

BATHROOM

114E

114A

ROOM

A-1

114B

CLOSET

A-1

LAUNDRY

VENDING

TV/LOUNGE

ENTRY

125STAIR

JAN

108A

ROOM

B-2

108B

CLOSET

B-2

DINING

108C

KITCHEN

108D

BATHROOM

108E

106C

CLOSET

B-1

104C

CLOSET

A-2DINING

102C

KITCHEN

102D

104B

CLOSET

A-2

106B

CLOSET

B-1

106A

ROOM

B-1

104A

ROOM

A-2

102A

ROOM

A-1

102B

CLOSET

A-1

STAIR

101B

CLOSET

B-2

101A

ROOM

B-2

103A

ROOM

B-1

103B

CLOSET

B-1

KITCHEN

101D

BATHROOM

101E

DINING

101C 103C

CLOSET

B-1

105C

CLOSET

A-2 DINING

107C

105A

ROOM

A-2

107A

ROOM

A-1

KITCHEN

107D

BATHROOM

107E105B

CLOSET

A-2

107B

CLOSET

A-1

OFFICE

MECH ROOM

CORRIDOR

ELEC

ELEC

UNISEX

UNISEX

113A

ROOM

B-2

115A

ROOM

B-1

117A

ROOM

A-2

119A

ROOM

A-1

DINING

113C 115C

CLOSET

B-1

117C

CLOSET

A-2 DINING

119C

KITCHEN

113D

KITCHEN

119D

113B

CLOSET

B-2

115B

CLOSET

B-1

117D

CLOSET

A-2

119B

CLOSET

A-1BATHROOM

119E

BATHROOM

113EMAILBOXES

CORRIDOR

STAIR

A-410 A6

A-401 A8

1 1 1 1

2 2

2 2

1 1 1 1 2 2

1 21

36 22

2 2

1 1 1 1 2 2

BATHROOM

102E

A-410 A7

RISER

ROOM

112 112 112

122A

122B

121A

123D

121B

PARTITION TAG

REFER TO PARTITION SCHEDULE

BUILDING SECTION TAG

WALL SECTION TAG

EXTERIOR ELEVATION TAG

PLAN REFERENCE TAG

ROOM NAME

EXISTING COLUMN GRID

DESIGNATIONS

1 A-211 INTERIOR ELEVATION TAG

ROOM NUMBER

NEW DOOR

WITH DOOR TAG

REF DOOR SCHED

NEW WINDOW

WITH WINDOW MARK

REF GLAZING ELEVATIONS

A-431

A1 X

A-201

A-301

1002 28

A

101A

DESCRIPTIONSYMBOL

FLOOR PLAN LEGEND

ROOM NAME

A-1 SUITE TYPE - ROOM IN SUITE

SUITE TYPE A - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

SUITE TYPE B - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

SUITE TYPE C - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

A

9 11

B

C

10 12

MECH ROOM

A-412 A8

A

2 3 4 5 6 7 9 11 13 14 15 16 17 18 19

B

C

D

8 10 12

DINING

120C

120A

ROOM

B-2

120B

CLOSET

B-2

KITCHEN

120D

BATHROOM

120E

118A

ROOM

B-1

118B

CLOSET

B-1

118C

CLOSET

B-1

116C

CLOSET

A-2

116A

ROOM

A-2

116B

CLOSET

A-2

KITCHEN

114D

DINING

114C

BATHROOM

114E

114A

ROOM

A-1

114B

CLOSET

A-1

LAUNDRY

VENDING

TV/LOUNGE

ENTRY

125STAIR

JAN

108A

ROOM

B-2

108B

CLOSET

B-2

DINING

108C

KITCHEN

108D

BATHROOM

108E

106C

CLOSET

B-1

104C

CLOSET

A-2DINING

102C

KITCHEN

102D

104B

CLOSET

A-2

106B

CLOSET

B-1

106A

ROOM

B-1

104A

ROOM

A-2

102A

ROOM

A-1

102B

CLOSET

A-1

STAIR

101B

CLOSET

B-2

101A

ROOM

B-2

103A

ROOM

B-1

103B

CLOSET

B-1

KITCHEN

101D

BATHROOM

101E

DINING

101C 103C

CLOSET

B-1

105C

CLOSET

A-2 DINING

107C

105A

ROOM

A-2

107A

ROOM

A-1

KITCHEN

107D

BATHROOM

107E105B

CLOSET

A-2

107B

CLOSET

A-1

OFFICE

MECH ROOM

CORRIDOR

ELEC

ELEC

UNISEX

UNISEX

113A

ROOM

B-2

115A

ROOM

B-1

117A

ROOM

A-2

119A

ROOM

A-1

DINING

113C 115C

CLOSET

B-1

117C

CLOSET

A-2 DINING

119C

KITCHEN

113D

KITCHEN

119D

113B

CLOSET

B-2

115B

CLOSET

B-1

117D

CLOSET

A-2

119B

CLOSET

A-1BATHROOM

119E

BATHROOM

113EMAILBOXES

CORRIDOR

STAIR

BATHROOM

A

SUITE QUANTITES FIRST FLOOR:

TYPE A - 4

TYPE B - 4

TYPE C - 0

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

FI

LE

N

AM

E:

US

ER

N

AM

E:

DA

TE

S

TA

M P:

REVISION HISTORY

AIR FORCE GLOBAL STRIKE COMMAND

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A ut od es k D oc s:

G O

1- M al m st ro m R en ov at e

D or m an d

2/

G O

1b

2- A

-R

-C

EN

TR

A

L.

rv t

5/ 5/

:4

6:

P M

A-101 09/16/2025

RF

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

CK

ARCHITECTURAL - FLOOR PLAN -

LEVEL 01

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

CH

SCALE: 1/8" = 1'-0"C1 ARCHITECTURAL - OVERALL FLOOR PLAN - LEVEL 01

KEYED NOTES 1

NUMBER DESCRIPTION

SCALE: 1/8" = 1'-0"A5 ARCHITECTURAL - FLOOR PLAN - MECHANICAL BASEMENT

SCALE: 1/8" = 1'-0"G1 ARCHITECTURAL - SUITE PLAN - LEVEL 01

74 EXISTING GRATED WALKWAY AND GUARDRAILS TO REMAIN.

100 INFILL CONCRETE SLAB. REF CIVIL.

111 FIRE SUPPRESSION EQUIPMENT UNDER STAIRS. REF FIRE SUPPRESSION.

112 SEMI-RECESSED FIRE EXTINGUISER CABINET.

122 NEW FIRE ALARM ACCESS PANEL. COORDINATE WITH FP.

1 BID ADDENDUM 1 5/8/2026

REF. REF.

REF.REF. REF.REF.

REF. REF.

R

EF

M

M

A-201

H1

A-201

A-201

A-201 D1

H7

A1

A

2 3 4 5 6 7 9 11 13 14 15 16 17 18 19

B

C

D

8 10 12

STAIR

220A

ROOM

B-2

218A

ROOM

B-1

DINING

220C218C

CLOSET

B-1

216C

CLOSET

A-2

KITCHEN

220D

BATHROOM

220E

220B

CLOSET

B-2

218B

CLOSET

B-1

216A

ROOM

A-2

216B

CLOSET

A-2

DINING

214C

KITCHEN

214D

BATHROOM

214E

214A

ROOM

A-1

214B

CLOSET

A-1

FOLDING

LAUNDRY

TV/LOUNGE

JAN

227208B

CLOSET

B-2

206B

CLOSET

B-1

204B

CLOSET

A-2

202B

CLOSET

A-1

DINING

208C206C

CLOSET

B-1

204C

CLOSET

A-2DINING

202C

208A

ROOM

B-2

206A

ROOM

B-1

204A

ROOM

A-2

202A

ROOM

A-1

KITCHEN

202D

KITCHEN

208D

BATHROOM

202E

BATHROOM

208E

219A

ROOM

A-1

217A

ROOM

A-2

215A

ROOM

B-1

213A

ROOM

B-2

211A

ROOM

C-2

209A

ROOM

C-1

207A

ROOM

A-1

205A

ROOM

A-2

203A

ROOM

B-1

201A

ROOM

B-2

201B

CLOSET

B-2

203B

CLOSET

B-1

205B

CLOSET

A-2

207B

CLOSET

A-1

209B

CLOSET

C-1

211B

CLOSET

C-2

213B

CLOSET

B-2

215B

CLOSET

B-1

217D

CLOSET

A-2

219B

CLOSET

A-1

DINING

219C217C

CLOSET

A-2

215C

CLOSET

B-1DINING

213C

DINING

207C205C

CLOSET

A-2

203C

CLOSET

B-1DINING

201C

KITCHEN

201D

BATHROOM

201E

BATHROOM

207E

KITCHEN

207D

ELEC

PERSONAL

STORAGE

209C

KITCHEN

209D

CORR

209E

BATHROOM

KITCHEN

213D

BATHROOM

213E

KITCHEN

219D

BATHROOM

219E

CORRIDOR

STAIR

LOBBY

STAIR

A-402 A7

A-411 A7

2 2

1 1 1 1 2 2

22 36 22

2 2

1 1 1 1 2 2

A-412 A3

A-401 A2

A-401 A8

TYP TYP

112 112

226 224

1222 1

FLOOR PLAN GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

REFER TO ENLARGED PLANS FOR NEW PARTITION TYPES AND LOCATIONS, AND FOR DOOR NUMBERS OF DOORS NOT

LABELED ON OVERALL PLANS.

CONTRACTOR TO VERIFY ALL EXISTING OPENING DIMENSIONS (DOOR, WINDOW, LOUVERS, ETC) IN THE FIELD.

SUITES TYPES ARE GROUPED (A,B,C) BASED ON GENERAL SIMILARITES OF THE LAYOUTS BETWEEN SUITES. CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD FOR EACH ROOM AS THE EXISTING CONDITIONS OF EACH SUITE TYPE MAY VARY.

FOR FIRE AND LIFE SAFETY PLANS, REFER TO F- DRAWINGS.

REFER TO A2 SERIES DRAWINGS, EXTERIOR ELEVATIONS, A3 BUILDING AND WALL SECTIONS.

REFER TO A6 SERIES FOR ALL PARTITIONS, DOORS, WINDOWS, AND ACCESSORIES.

REFER TO I-SHEETS FOR INTERIOR FINISHES.

REFER TO IG SERIES FOR INTERIOR SIGNAGE.

INSTALL BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED DEVICES.

GENERAL DIMENSIONS PROVIDED ON FLOOR PLANS AND AREA PLANS DO NOT REFLECT THE ROUGH OPENING DIMENSIONS REQUIRED FOR COORDINATION WITH MASONRY JOINT COURSING. CONTRACTOR IS TO PROVIDE ROUGH OPENING FRAMING DIMENSIONS CONSISTENT WITH ENLARGED ARCHITECTURAL PLAN/SECTION DETAILS (A5 SERIES SHEETS), AND WINDOW SCHEDULE/DETAILS (A6 SERIES). CONTRACTOR TO SUBMIT RFI FOR ANY ROUGH OPENING DIMENSIONS NOT GIVEN IN

DETAILING FOR CLARIFICATION REQUIRED.

REFER TO "TYPICAL SUITE PLANS AND ELEVATIONS" SHEETS FOR ENLARGED PLANS, RCPS, AND INTERIOR ELVATIONS OF

TYPICAL SUITES.

SUITE PLAN SHOWN AS A REFERENCE TO IDENTIFY THE LOCATION OF EACH SUITE ON EACH FLOOR

PROVIDE NEW GUARDRAILS AND RAILINGS AT ALL STAIRS.

SUITE BATHROOM ACCESSORIES INCLUDE (1) TOILET PAPER HOLDER, (2) TOWEL BARS AND (1) SHOWER ROD. REFER TO

G-001 FOR TYPICAL MOUNTING HEIGHTS OF ACCESSORIES, UNO.

PARTITION TAG

REFER TO PARTITION SCHEDULE

BUILDING SECTION TAG

WALL SECTION TAG

EXTERIOR ELEVATION TAG

PLAN REFERENCE TAG

ROOM NAME

EXISTING COLUMN GRID

DESIGNATIONS

1 A-211 INTERIOR ELEVATION TAG

ROOM NUMBER

NEW DOOR

WITH DOOR TAG

REF DOOR SCHED

NEW WINDOW

WITH WINDOW MARK

REF GLAZING ELEVATIONS

A-431

A1 X

A-201

A-301

1002 28

A

101A

DESCRIPTIONSYMBOL

FLOOR PLAN LEGEND

ROOM NAME

A-1 SUITE TYPE - ROOM IN SUITE

SUITE TYPE A - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

SUITE TYPE B - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

SUITE TYPE C - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

A

2 3 4 5 6 7 9 11 13 14 15 16 17 18 19

B

C

D

8 10 12

STAIR

220A

ROOM

B-2

218A

ROOM

B-1

DINING

220C218C

CLOSET

B-1

216C

CLOSET

A-2

KITCHEN

220D

BATHROOM

220E

220B

CLOSET

B-2

218B

CLOSET

B-1

216A

ROOM

A-2

216B

CLOSET

A-2

DINING

214C

KITCHEN

214D

BATHROOM

214E

214A

ROOM

A-1

214B

CLOSET

A-1FOLDING

LAUNDRY

TV/LOUNGE

JAN

227208B

CLOSET

B-2

206B

CLOSET

B-1

204B

CLOSET

A-2

202B

CLOSET

A-1

DINING

208C206C

CLOSET

B-1

204C

CLOSET

A-2DINING

202C

208A

ROOM

B-2

206A

ROOM

B-1

204A

ROOM

A-2

202A

ROOM

A-1

KITCHEN

202D

KITCHEN

208D

BATHROOM

202E

BATHROOM

208E

219A

ROOM

A-1

217A

ROOM

A-2

215A

ROOM

B-1

213A

ROOM

B-2

211A

ROOM

C-2

209A

ROOM

C-1

207A

ROOM

A-1

205A

ROOM

A-2

203A

ROOM

B-1

201A

ROOM

B-2

201B

CLOSET

B-2

203B

CLOSET

B-1

205B

CLOSET

A-2

207B

CLOSET

A-1

209B

CLOSET

C-1

211B

CLOSET

C-2

213B

CLOSET

B-2

215B

CLOSET

B-1

217D

CLOSET

A-2

219B

CLOSET

A-1

DINING

219C217C

CLOSET

A-2

215C

CLOSET

B-1DINING

213C

DINING

207C205C

CLOSET

A-2

203C

CLOSET

B-1DINING

201C

KITCHEN

201D

BATHROOM

201E BATHROOM

207E

KITCHEN

207D

ELEC

PERSONAL

STORAGE

209C

KITCHEN

209D

CORR

209E

BATHROOM

KITCHEN

213D

BATHROOM

213E

KITCHEN

219D

BATHROOM

219E

CORRIDOR

STAIR

LOBBY

STAIR

SUITE QUANTITES SECOND FLOOR:

TYPE A - 4

TYPE B - 4

TYPE C - 1

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

FI

LE

N

N

AM

E:

DA

TE

S

TA

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A ut od es k D oc s:

G O

1- M al m st ro m R en ov at e

D or m an d

2/

G O

1b

2- A

-R

-C

EN

TR

A

L.

rv t

5/ 5/

:4

6:

P M

A-102 09/16/2025

RF

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

CK

ARCHITECTURAL - FLOOR PLAN -

LEVEL 02

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

CHSCALE: 1/8" = 1'-0"A1 ARCHITECTURAL - FLOOR PLAN - LEVEL 02

SCALE: 1/8" = 1'-0"F1 ARCHITECTURAL - SUITE PLAN - LEVEL 02

KEYED NOTES 1

NUMBER DESCRIPTION

112 SEMI-RECESSED FIRE EXTINGUISER CABINET.

REF. REF.

REF.REF. REF.REF.

REF. REF.

R

EF

FLOOR PLAN GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

REFER TO ENLARGED PLANS FOR NEW PARTITION TYPES AND LOCATIONS, AND FOR DOOR NUMBERS OF DOORS NOT

LABELED ON OVERALL PLANS.

CONTRACTOR TO VERIFY ALL EXISTING OPENING DIMENSIONS (DOOR, WINDOW, LOUVERS, ETC) IN THE FIELD.

SUITES TYPES ARE GROUPED (A,B,C) BASED ON GENERAL SIMILARITES OF THE LAYOUTS BETWEEN SUITES. CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD FOR EACH ROOM AS THE EXISTING CONDITIONS OF EACH SUITE TYPE MAY VARY.

FOR FIRE AND LIFE SAFETY PLANS, REFER TO F- DRAWINGS.

REFER TO A2 SERIES DRAWINGS, EXTERIOR ELEVATIONS, A3 BUILDING AND WALL SECTIONS.

REFER TO A6 SERIES FOR ALL PARTITIONS, DOORS, WINDOWS, AND ACCESSORIES.

REFER TO I-SHEETS FOR INTERIOR FINISHES.

REFER TO IG SERIES FOR INTERIOR SIGNAGE.

INSTALL BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED DEVICES.

GENERAL DIMENSIONS PROVIDED ON FLOOR PLANS AND AREA PLANS DO NOT REFLECT THE ROUGH OPENING DIMENSIONS REQUIRED FOR COORDINATION WITH MASONRY JOINT COURSING. CONTRACTOR IS TO PROVIDE ROUGH OPENING FRAMING DIMENSIONS CONSISTENT WITH ENLARGED ARCHITECTURAL PLAN/SECTION DETAILS (A5 SERIES SHEETS), AND WINDOW SCHEDULE/DETAILS (A6 SERIES). CONTRACTOR TO SUBMIT RFI FOR ANY ROUGH OPENING DIMENSIONS NOT GIVEN IN

DETAILING FOR CLARIFICATION REQUIRED.

REFER TO "TYPICAL SUITE PLANS AND ELEVATIONS" SHEETS FOR ENLARGED PLANS, RCPS, AND INTERIOR ELVATIONS OF

TYPICAL SUITES.

SUITE PLAN SHOWN AS A REFERENCE TO IDENTIFY THE LOCATION OF EACH SUITE ON EACH FLOOR

PROVIDE NEW GUARDRAILS AND RAILINGS AT ALL STAIRS.

SUITE BATHROOM ACCESSORIES INCLUDE (1) TOILET PAPER HOLDER, (2) TOWEL BARS AND (1) SHOWER ROD. REFER TO

G-001 FOR TYPICAL MOUNTING HEIGHTS OF ACCESSORIES, UNO.

PARTITION TAG

REFER TO PARTITION SCHEDULE

BUILDING SECTION TAG

WALL SECTION TAG

EXTERIOR ELEVATION TAG

PLAN REFERENCE TAG

ROOM NAME

EXISTING COLUMN GRID

DESIGNATIONS

1 A-211 INTERIOR ELEVATION TAG

ROOM NUMBER

NEW DOOR

WITH DOOR TAG

REF DOOR SCHED

NEW WINDOW

WITH WINDOW MARK

REF GLAZING ELEVATIONS

A-431

A1 X

A-201

A-301

1002 28

A

101A

DESCRIPTIONSYMBOL

FLOOR PLAN LEGEND

ROOM NAME

A-1 SUITE TYPE - ROOM IN SUITE

SUITE TYPE A - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

SUITE TYPE B - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

SUITE TYPE C - REFER TO A-401 FOR TYPICAL SUITE ENLARGED PLANS, REFLECTED

CEILING PLANS AND INTERIOR ELEVATION

A-201

H1

A-201

A-201

A-201 D1

H7

A1

A

2 3 4 5 6 7 9 11 13 14 15 16 17 18 19

B

C

D

8 10 12

320A

ROOM

B-2

318A

ROOM

B-1

316A

ROOM

A-2

314A

ROOM

A-1

LAUNDRY

FOLDING

TV/LOUNGE

LOBBY

JAN

PERSONAL

STORAGE

ELEC

308A

ROOM

B-2

306A

ROOM

B-1

302A

ROOM

A-1

DINING

302C 304C

CLOSET

A-2

306C

CLOSET

B-1 DINING

308C

DINING

314C 316C

CLOSET

A-2

318C

CLOSET

B-1 DINING

320C

KITCHEN

320D

BATHROOM

320E

320B

CLOSET

B-2

318B

CLOSET

B-1

316B

CLOSET

A-2

KITCHEN

314D

BATHROOM

314E

314B

CLOSET

A-1

KITCHEN

308D

BATHROOM

308E

308B

CLOSET

B-2

306B

CLOSET

B-1

304B

CLOSET

A-2

302B

CLOSET

A-1

KITCHEN

302D

STAIR

STAIR

CORRIDOR

319B

CLOSET

A-1

317D

CLOSET

A-2

315B

CLOSET

B-1

315C

CLOSET

B-1

317C

CLOSET

A-2 DINING

319C

319A

ROOM

A-1

KITCHEN

319D

BATHROOM

319E

317A

ROOM

A-2

315A

ROOM

B-1

KITCHEN

313D

DINING

313C

BATHROOM

313E

313A

ROOM

B-2

313B

CLOSET

B-2

311B

CLOSET

C-2

311A

ROOM

C-2

KITCHEN

309C

CORR

309D

BATHROOM

309E

309A

ROOM

C-1

309B

CLOSET

C-1

301A

ROOM

B-2

301B

CLOSET

B-2

DINING

301C

KITCHEN

301D

BATHROOM

301E

303A

ROOM

B-1

303B

CLOSET

B-1

303C

CLOSET

B-1

305A

ROOM

A-2

305B

CLOSET

A-2

305C

CLOSET

A-2

307A

ROOM

A-1

307B

CLOSET

A

DINING

307C

KITCHEN

307D

BATHROOM

307E

STAIR

BATHROOM

302E

304A

ROOM

A-2

2 2

1 1 1 1 2 2

1 36

22 36 22

2 2

1 1 1 1 2 2

113711

A-412 A1

B23 B13 A23 A13

A-411 A9

112 112 112

A-402 A7

A-401 A2

A-401 A8

326 324

A

2 3 4 5 6 7 9 11 13 14 15 16 17 18 19

B

C

D

8 10 12

320A

ROOM

B-2

318A

ROOM

B-1

316A

ROOM

A-2

314A

ROOM

A-1

LAUNDRY

FOLDING

TV/LOUNGE

LOBBY

JAN

PERSONAL

STORAGE

ELEC

308A

ROOM

B-2

306A

ROOM

B-1

302A

ROOM

A-1

DINING

302C 304C

CLOSET

A-2

306C

CLOSET

B-1 DINING

308C

DINING

314C 316C

CLOSET

A-2

318C

CLOSET

B-1 DINING

320C

KITCHEN

320D

BATHROOM

320E

320B

CLOSET

B-2

318B

CLOSET

B-1

316B

CLOSET

A-2

KITCHEN

314D

BATHROOM

314E

314B

CLOSET

A-1

KITCHEN

308D

BATHROOM

308E

308B

CLOSET

B-2

306B

CLOSET

B-1

304B

CLOSET

A-2

302B

CLOSET

A-1

KITCHEN

302D

STAIR

STAIR

CORRIDOR

319B

CLOSET

A-1

317D

CLOSET

A-2

315B

CLOSET

B-1

315C

CLOSET

B-1

317C

CLOSET

A-2 DINING

319C

319A

ROOM

A-1

KITCHEN

319D

BATHROOM

319E

317A

ROOM

A-2

315A

ROOM

B-1

KITCHEN

313D

DINING

313C

BATHROOM

313E

313A

ROOM

B-2

313B

CLOSET

B-2

311B

CLOSET

C-2

311A

ROOM

C-2

KITCHEN

309C

CORR

309D

BATHROOM

309E

309A

ROOM

C-1

309B

CLOSET

C-1

301A

ROOM

B-2

301B

CLOSET

B-2

DINING

301C

KITCHEN

301D

BATHROOM

301E

303A

ROOM

B-1

303B

CLOSET

B-1

303C

CLOSET

B-1

305A

ROOM

A-2

305B

CLOSET

A-2

305C

CLOSET

A-2

307A

ROOM

A-1

307B

CLOSET

A

DINING

307C

KITCHEN

307D

BATHROOM

307E

STAIR

BATHROOM

302E

304A

ROOM

A-2

SUITE QUANTITES THIRD FLOOR:

TYPE A - 4

TYPE B - 4

TYPE C - 1

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

FI

LE

N

N

AM

E:

DA

TE

S

TA

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A ut od es k D oc s:

G O

1- M al m st ro m R en ov at e

D or m an d

2/

G O

1b

2- A

-R

-C

EN

TR

A

L.

rv t

5/ 5/

:4

6:

P M

A-103 09/16/2025

RF

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

CK

ARCHITECTURAL - FLOOR PLAN -

LEVEL 03

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

CHSCALE: 1/8" = 1'-0"A1 ARCHITECTURAL - FLOOR PLAN - LEVEL 03

SCALE: 1/8" = 1'-0"F1 ARCHITECTURAL - SUITE PLAN - LEVEL 03

KEYED NOTES 1

NUMBER DESCRIPTION

112 SEMI-RECESSED FIRE EXTINGUISER CABINET.

A

7 9 11 13

B

8 10 12

OFFICE

ELEC

ELEC

UNISEX

UNISEX

MAILBOXES

CORRIDOR

CORRIDOR

A-410 J3 A-410G5

J5 G3

F1

F3 F3

F1

7'

- 1

7/ 8"

1' - 8 5/8" 6' - 5 5/8"126

134B137

130 132 138B138A

MECH

ROOM

MECH

ROOM

A-630

E10

J7

F5 A-501A6

A-501

CL

R3"

F2

A-402

A5

134A

A

7 9 11 13

B

8 10 12

OPEN TO

ABOVE

OPEN TO

ABOVE

OPEN TO ABOVE

OFFICE

CORRIDOR

MAILBOXES 130

UNISEX

UNISEX

ELEC

ELEC

MECH

ROOM

CORRIDOR

F5 A-501

A6 A-501

A.F.F.7' - 6" A.F.F.7' - 6"

A.F.F.7' - 6"

A.F.F.7' - 6"

A.F.F.7' - 10"

7'

- 2

2'

- 2

5' - 11"

3' - 6"

4'

- 5

4' - 6"

5'

- 9

2' - 0"

MIRROR

4 F

UL

L R

OW

S

1'

- 6

2'

- 1

1"

3' - 6"1' - 0"

8 7/8"

2'

- 1

0"

3' - 4"

4 F

UL

L R

OW

S

1'

- 6

4 F

UL

L R

OW

S

2' - 0" 1' - 0" 6"

2'

- 1

1"

1'

- 6

4 F

UL

L R

OW

S

9 11 13

C

D

8 10 12

TV/LOUNGE

VENDING

LAUNDRY

A-410G9 J9

ENTRY

A-402

A5

A-402

A5

A-402

A5

123A

127 127

125A

125B

123B

9 11 13

C

D

8 10 12

TV/LOUNGE

VENDING

LAUNDRY

ENTRY

A.F.F.8' - 0"

A.F.F.8' - 0"

A.F.F.7' - 9"

A.F.F.8' - 0"125

ENTRY

A.F.F.8' - 4"

2' - 10" 2' - 10"

5'

- 1

1"

4'

- 0

3'

- 0

3' - 7"

BL

MIRROR 223

4 F

UL

L R

OW

S

PARTITION TAG

REFER TO PARTITION SCHEDULE

BUILDING SECTION TAG

WALL SECTION TAG

EXTERIOR ELEVATION TAG

PLAN REFERENCE TAG

ROOM NAME

EXISTING COLUMN GRID

DESIGNATIONS

1 A-211 INTERIOR ELEVATION TAG

ROOM NUMBER

NEW DOOR

WITH DOOR TAG

REF DOOR SCHED

NEW WINDOW

WITH WINDOW MARK

REF GLAZING ELEVATIONS

A-431

A1 X

A-201

A-301

1002 28

A

101A

DESCRIPTIONSYMBOL

FLOOR PLAN LEGEND

ROOM NAME

A-1 SUITE TYPE - ROOM IN SUITE

FLOOR PLAN GENERAL NOTES

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

REFER TO ENLARGED PLANS FOR NEW PARTITION TYPES AND LOCATIONS.

CONTRACTOR TO VERIFY ALL EXISTING OPENING DIMENSIONS (DOOR, WINDOW, LOUVERS, ETC) IN THE FIELD.

SUITES TYPES ARE GROUPED (A,B,C) BASED ON GENERAL SIMILARITES OF THE LAYOUTS BETWEEN SUITES. CONTRACTOR TO VERIFY ALL DIMENSIONS IN THE FIELD FOR EACH ROOM AS THE EXISTING CONDITIONS OF EACH SUITE TYPE MAY VARY.

FOR FIRE AND LIFE SAFETY PLANS, REFER TO F- DRAWINGS.

REFER TO A2 SERIES DRAWINGS, EXTERIOR ELEVATIONS, A3 BUILDING AND WALL SECTIONS.

REFER TO A6 SERIES FOR ALL PARTITIONS, DOORS, WINDOWS, AND ACCESSORIES.

REFER TO I-SHEETS FOR INTERIOR FINISHES.

REFER TO IG SERIES FOR INTERIOR SIGNAGE.

INSTALL BLOCKING AS REQUIRED TO SUPPORT WALL MOUNTED DEVICES.

GENERAL DIMENSIONS PROVIDED ON FLOOR PLANS AND AREA PLANS DO NOT REFLECT THE ROUGH OPENING DIMENSIONS REQUIRED FOR COORDINATION WITH MASONRY JOINT COURSING. CONTRACTOR IS TO PROVIDE ROUGH OPENING FRAMING DIMENSIONS CONSISTENT WITH ENLARGED ARCHITECTURAL PLAN/SECTION DETAILS (A5 SERIES SHEETS), AND WINDOW SCHEDULE/DETAILS (A6 SERIES). CONTRACTOR TO SUBMIT RFI FOR ANY ROUGH OPENING DIMENSIONS NOT GIVEN IN

DETAILING FOR CLARIFICATION REQUIRED.

REFER TO "TYPICAL SUITE PLANS AND ELEVATIONS" SHEETS FOR ENLARGED PLANS, RCPS, AND INTERIOR ELVATIONS OF

TYPICAL SUITES.

SUITE PLAN SHOWN AS A REFERENCE TO IDENTIFY THE LOCATION OF EACH SUITE ON EACH FLOOR

PROVIDE NEW GUARDRAILS AND RAILINGS AT ALL STAIRS.

SUITE BATHROOM ACCESSORIES INCLUDE (1) TOILET PAPER HOLDER, (2) TOWEL BARS AND (1) SHOWER ROD. REFER TO

G-001 FOR TYPICAL MOUNTING HEIGHTS OF ACCESSORIES, UNO.

REFER TO MEP FOR LOCATION OF NEW CONCRETE PADS FOR MECHANICAL AND/OR PLUMBING EQUIPMENT. REFER TO

STRUCTURAL FOR ADDITIONAL INFORMATION ON PAD CONSTRUCTION

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

FI

LE

N

N

AM

E:

DA

TE

S

TA

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A ut od es k D oc s:

G O

1- M al m st ro m R en ov at e

D or m an d

2/

G O

1b

2- A

-R

-C

EN

TR

A

L.

rv t

5/ 5/

:4

7:

P M

A-410 09/16/2025

RF

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

CK

ARCHITECTURAL - ENLARGED

FLOOR PLANS AND RCP

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

CH

SCALE: 1/4" = 1'-0"A6 ENLARGED FLOOR PLAN - 1ST FLOOR MECHANICAL & PUBLIC SPACES

SCALE: 1/4" = 1'-0"D6 ENLARGED REFLECTED CEILING PLAN - 1ST FLOOR MECHANICAL & PUBLIC SPACES

SCALE: 1/4" = 1'-0"A7 ENLARGED FLOOR PLAN - 1ST FLOOR LOBBY, LOUNGE & LAUNDRY

SCALE: 3/8" = 1'-0"J3 RESTROOM 130 - EAST ELEVATION

SCALE: 3/8" = 1'-0"J5 RESTROOM 132 - NORTH ELEVATION

SCALE: 3/8" = 1'-0"G3 RESTROOM 130 - NORTH ELEVATION

SCALE: 3/8" = 1'-0"G5 RESTROOM 132 - WEST ELEVATION

SCALE: 1/4" = 1'-0"D7 REFLECTED CEILING PLAN - 1ST FLOOR LOBBY, LOUNGE & LAUNDRY

SCALE: 3/8" = 1'-0"G9 LAUNDRY ROOM - WEST ELEVATION

SCALE: 3/8" = 1'-0"J9 LAUNDRY ROOM - EAST ELEVATIONSCALE: 3/8" = 1'-0"J7 RESTROOM 132 - EAST ELEVATION

KEYED NOTES 1

NUMBER DESCRIPTION

127 RETURN AND INSTALL STORED VENDING MACHINE AND ICE MAKER

132 SLAB INFILL. REF STRUC.

134 INFILL GYPSUM WALL BOARD TO MATCH EXISTING ADJACENT CONSTRUCTION.

223 RECESSED PAPER TOWEL DISPENSER AND TRASH CAN. INSTALL IN SAME

LOCATION AS EXISTING.

NOTE: WASHERS & DRYERS SHOWN FOR REFERENCE. OWNER TO

INSTALL WASHERS & DRYERS AFTER COMPLETION OF THIS PROJECT.

NOTE: WASHERS & DRYERS SHOWN FOR REFERENCE. OWNER TO

INSTALL WASHERS & DRYERS AFTER COMPLETION OF THIS PROJECT.

2 3 4 5 6 7 9 11 13 14 15 16 17 18 19

B

C

D

8 10 12

STAIR

220A

ROOM

B-2218A

ROOM

B-1

220C

DINING

B

218C

CLOSET

B-1

216C

CLOSET

A-2

220D

KITCHEN

B

220E

BATHROOM

B

220B

CLOSET

B-2

218B

CLOSET

B-1

216A

ROOM

A-2

216B

CLOSET

A-2

214C

DINING

A

214D

KITCHEN

A

214E

BATHROOM

A

214A

ROOM

A-1

214B

CLOSET

A-1

FOLDING

LAUNDRY

TV/LOUNGE

JAN

208B

CLOSET

B-2

206B

CLOSET

B-1

204B

CLOSET

A-2

202B

CLOSET

A-1

208C

DINING

B

206C

CLOSET

B-1 204C

CLOSET

A-2

202C

DINING

A

208A

ROOM

B-2

206A

ROOM

B-1 204A

ROOM

A-2

202A

ROOM

A-1

202D

KITCHEN

A

208D

KITCHEN

B

202E

BATHROOM

A

208E

BATHROOM

B

219A

ROOM

A-1 217A

ROOM

A-2

215A

ROOM

B-1213A

ROOM

B-2

211A

ROOM

C-2 209A

ROOM

C-1 207A

ROOM

A-1

205A

ROOM

A-2

203A

ROOM

B-1 201A

ROOM

B-2

201B

CLOSET

B-2

203B

CLOSET

B-1 205B

CLOSET

A-2

207B

CLOSET

A-1

209B

CLOSET

C-1 211B

CLOSET

C-2

213B

CLOSET

B-2

215B

CLOSET

B-1

217D

CLOSET

A-2

219B

CLOSET

A-1

219C

DINING

A

217C

CLOSET

A-2

215C

CLOSET

B-1

213C

DINING

B207C

DINING

A

205C

CLOSET

A-2

203C

CLOSET

B-1

201C

DINING

B

201D

KITCHEN

B

201E

BATHROOM

B

207E

BATHROOM

A

207D

KITCHEN

A

ELEC

PERSONAL

STORAGE

209C

KITCHEN

C

209D

CORR

C

209E

BATHROOM

C

213D

KITCHEN

B

213E

BATHROOM

B

219D

KITCHEN

A

219E

BATHROOM

A

CORRIDOR

STAIR

LOBBY

STAIR

RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS2 RS2

RS2RS2RS2RS2RS2RS2

RS2RS1RS1

RS2RS2RS2RS2RS2RS2RS2

A-411

E7

A-401

D2 TYP TYP

A-401

D8

5'

2'

A-402

D7

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

111111111111

1. ALL CEILINGS HEIGHTS IN "CORRIDORS" SHALL BE 7' -6" AFF UNLESS NOTED OTHERWISE.

2. ALL OFFICE CEILING HEIGHTS SHALL BE 7'-6" AFF UNLESS NOTED OTHERWISE.

3. ALL ACOUSTICAL CEILING GRIDS TO BE CENTERED WITHIN ROOM UNLESS NOTED OTHERWISE.

4. ALL CORRIDOR ACOUSTICAL CEILING GRIDS TO BE CENTERED WITHIN THE CORRIDOR, UNLESS NOTED OTHERWISE.

5. ALL 'CAN' LIGHT FIXTURES TO BE CENTERED WITHIN ACOUSTICAL CEILING TILES.

6. ALL DIFFUSERS AND AIR GRILLES SHALL BE PAINTED TO MATCH THE WALL OR CEILING THEY ARE INSTALLED IN U.N.O.

7. INSTALL NEW LIGHT FIXTURES AT EXISTING LOCATIONS UNLESS NOTED OTHERWISE.

8. REFER TO ENLARGED CEILING PLANS FOR ADDITIONAL INFORMATION ON CEILING HEIGHTS.

9. REFER TO "TYPICAL SUITE PLANS AND ELEVATIONS" SHEETS FOR ENLARGED PLANS, RCPS, AND INTERIOR ELEVATIONS OF

TYPICAL SUITES.

CEILING PLAN GENERAL NOTES

DESCRIPTIONSYMBOL

CEILING PLAN LEGEND

2'x2' ACOUSTIC CEILING TILE

NEW GYPSUM CEILING

24"x24" LIGHT FIXTURE. REF ELEC

ACCESS PANEL

SUPPLY

RETURN

DOWNLIGHT

EXHAUST

48"x24" LIGHT FIXTURE. REF ELEC

SLOT DIFFUSER

48"x12" LIGHT FIXTURE. REF ELEC

EXTENTS OF CEILING INFILL TO ACCOMMODATE MECHANICAL WORK. VERIFY EXTENTS

WITH CEILING DEMOLITION REQUIRED CONDUCT MECHANICAL WORK. REF MECH.

SURFACE MOUNTED LIGHT

SURFACE MOUNTED LIGHT

EXISTING GYPSUM CEILING

EXPOSED STRUCTURE

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

F

IL

E N

A M

E

U

SE

R N

A M

E

D A

T E S

T A

M P

REVISION HISTORY

AIR FORCE GLOBAL STRIKE COMMAND

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A u to d e sk

D o cs

/3

G

O -M a lm st ro m R e n o v a te

D o rm a n d

/3

G

O b -A

-R -C

E N

T R A L .r v t

/1

/2

:3

:2

P

M

AC-102

09/16/2025

RF

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

CK

ARCHITECTURAL - REFLECTED

CEILING PLAN - LEVEL 02

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

CH

SCALE: 1/8" = 1'-0"D1

ARCHITECTURAL - OVERALL REFLECTED CEILING PLAN - LEVEL 02

KEYED NOTES 1

NUMBER DESCRIPTION

2 3 4 5 6 7 9 11 13 14 15 16 17 18 19

B

C

D

8 10 12

320A

ROOM

B-2

318A

ROOM

B-1

316A

ROOM

A-2

314A

ROOM

A-1

LAUNDRY

FOLDING

TV/LOUNGE

LOBBY

JAN

PERSONAL

STORAGE

ELEC

308A

ROOM

B-2

306A

ROOM

B-1

302A

ROOM

A-1

302C

DINING

A

304C

CLOSET

A-2

306C

CLOSET

B-1

308C

DINING

B

314C

DINING

A

316C

CLOSET

A-2

318C

CLOSET

B-1

320C

DINING

B

320D

KITCHEN

B

320E

BATHROOM

B

320B

CLOSET

B-2

318B

CLOSET

B-1

316B

CLOSET

A-2

314D

KITCHEN

A

314E

BATHROOM

A

314B

CLOSET

A-1

308D

KITCHEN

B

308E

BATHROOM

B

308B

CLOSET

B-2

306B

CLOSET

B-1

304B

CLOSET

A-2

302B

CLOSET

A-1

302D

KITCHEN

A

STAIR

STAIR

CORRIDOR

319B

CLOSET

A-1

317D

CLOSET

A-2

315B

CLOSET

B-1

315C

CLOSET

B-1 317C

CLOSET

A-2

319C

DINING

319A

ROOM

A-1

319D

KITCHEN

A

319E

BATHROOM

A

317A

ROOM

A-2

315A

ROOM

B-1

313D

KITCHEN

B

313C

DINING

B

313E

BATHROOM

B

313A

ROOM

B-2

313B

CLOSET

B-2

311B

CLOSET

C-2 311A

ROOM

C-2309C

KITCHEN

C

309D

CORR

C

309E

BATHROOM

C

309A

ROOM

C-1

309B

CLOSET

C-1

301A

ROOM

B-2

301B

CLOSET

B-2

301C

DINING

B

301D

KITCHEN

B

301E

BATHROOM

B

303A

ROOM

B-1

303B

CLOSET

B-1

303C

CLOSET

B-1

305A

ROOM

A-2

305B

CLOSET

A-2

305C

CLOSET

A-2

307A

ROOM

A-1

307B

CLOSET

A

307C

DINING

A

307D

KITCHEN

A

307E

BATHROOM

A

STAIR

302E

BATHROOM

A

304A

ROOM

A-2

A-411

D9

RS2 RS2 RS2 RS2 RS2 RS2 RS2

RS1 RS1 RS2

RS2 RS2 RS2 RS2 RS2 RS2

RS2RS2RS2RS2RS2RS2RS2RS2RS2RS2RS2RS2RS2RS2RS2

AD-107

D1

TYP TYP

AD-107

D1

5'

2'

AD-107

D1

1 1 1 1 1 1 1 1 1 1 1 1 1 1 1

111111111111

1. ALL CEILINGS HEIGHTS IN "CORRIDORS" SHALL BE 7' -6" AFF UNLESS NOTED OTHERWISE.

2. ALL OFFICE CEILING HEIGHTS SHALL BE 7'-6" AFF UNLESS NOTED OTHERWISE.

3. ALL ACOUSTICAL CEILING GRIDS TO BE CENTERED WITHIN ROOM UNLESS NOTED OTHERWISE.

4. ALL CORRIDOR ACOUSTICAL CEILING GRIDS TO BE CENTERED WITHIN THE CORRIDOR, UNLESS NOTED OTHERWISE.

5. ALL 'CAN' LIGHT FIXTURES TO BE CENTERED WITHIN ACOUSTICAL CEILING TILES.

6. ALL DIFFUSERS AND AIR GRILLES SHALL BE PAINTED TO MATCH THE WALL OR CEILING THEY ARE INSTALLED IN U.N.O.

7. INSTALL NEW LIGHT FIXTURES AT EXISTING LOCATIONS UNLESS NOTED OTHERWISE.

8. REFER TO ENLARGED CEILING PLANS FOR ADDITIONAL INFORMATION ON CEILING HEIGHTS.

9. REFER TO "TYPICAL SUITE PLANS AND ELEVATIONS" SHEETS FOR ENLARGED PLANS, RCPS, AND INTERIOR ELEVATIONS OF

TYPICAL SUITES.

CEILING PLAN GENERAL NOTES

DESCRIPTIONSYMBOL

CEILING PLAN LEGEND

2'x2' ACOUSTIC CEILING TILE

NEW GYPSUM CEILING

24"x24" LIGHT FIXTURE. REF ELEC

ACCESS PANEL

SUPPLY

RETURN

DOWNLIGHT

EXHAUST

48"x24" LIGHT FIXTURE. REF ELEC

SLOT DIFFUSER

48"x12" LIGHT FIXTURE. REF ELEC

EXTENTS OF CEILING INFILL TO ACCOMMODATE MECHANICAL WORK. VERIFY EXTENTS

WITH CEILING DEMOLITION REQUIRED CONDUCT MECHANICAL WORK. REF MECH.

SURFACE MOUNTED LIGHT

SURFACE MOUNTED LIGHT

EXISTING GYPSUM CEILING

EXPOSED STRUCTURE

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

F

IL

E N

A M

E

U

SE

R N

A M

E

D A

T E S

T A

M P

REVISION HISTORY

AIR FORCE GLOBAL STRIKE COMMAND

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A u to d e sk

D o cs

/3

G

O -M a lm st ro m R e n o v a te

D o rm a n d

/3

G

O b -A

-R -C

E N

T R A L .r v t

/1

/2

:3

:3

P

M

AC-103

09/16/2025

RF

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

CK

ARCHITECTURAL - REFLECTED

CEILING PLAN - LEVEL 03

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

CH

SCALE: 1/8" = 1'-0"D1

ARCHITECTURAL - OVERALL REFLECTED CEILING PLAN - LEVEL 03

KEYED NOTES 1

ROOM

108A

CPT-2

RWB-1

ROOM

101A

CPT-2

RWB-1

CLOSET

101B

CPT-2

RWB-1

DINING

101C

LVT-1

RWB-1

KITCHEN

101D

LVT-1

RWB-1

ROOM

103A

CPT-2

RWB-1

TV/LOUNGE

CPT-1

RWB-1

OFFICE

CPT-1

RWB-1

CORRIDOR

TIL-1

TWB-1

CORRIDOR

CPT-1

RWB-1

MECH ROOM

SEC-1

RWB-2

ELEC

SEC-1

RWB-2

ELEC

SEC-1

RWB-2

ENTRY

TIL-1

TWB-1

JAN

RSF-1

RWB-2

STAIR

RSL-1/RSN-1

RWB-2

LAUNDRY

RSF-1

INT-1

VENDING

RSF-1

INT-1

ROOM

114A

CPT-2

RWB-1

CLOSET

114B

CPT-2

RWB-1

CLOSET

113B

CPT-2

RWB-1

ROOM

113A

CPT-2

RWB-1

DINING

113C

LVT-1

RWB-1

KITCHEN

113D

LVT-1

RWB-1

ROOM

115A

CPT-2

RWB-1

CLOSET

115C

CPT-2

RWB-1

CLOSET

117C

CPT-2

RWB-1

ROOM

117A

CPT-2

RWB-1

CLOSET

115B

CPT-2

RWB-1

CLOSET

117D

CPT-2

RWB-1

KITCHEN

119D

LVT-1

RWB-1

DINING

119C

LVT-1

RWB-1

ROOM

119A

CPT-2

RWB-1

CLOSET

119B

CPT-2

RWB-1

STAIR

RSL-1/RSN-1

RWB-2

CLOSET

120B

CPT-2

RWB-1

ROOM

120A

CPT-2

RWB-1

KITCHEN

120D

LVT-1

RWB-1

DINING

120C

LVT-1

RWB-1

ROOM

118A

CPT-2

RWB-1

CLOSET

118C

CPT-2

RWB-1

CLOSET

118B

CPT-2

RWB-1

CLOSET

116B

CPT-2

RWB-1

ROOM

116A

CPT-2

RWB-1

CLOSET

116C

CPT-2

RWB-1

KITCHEN

114D

LVT-1

RWB-1

DINING

114C

LVT-1

RWB-1

CLOSET

103C

CPT-2

RWB-1

CLOSET

105C

CPT-2

RWB-1

DINING

107C

LVT-1

RWB-1

ROOM

105A

CPT-2

RWB-1

CLOSET

103B

CPT-2

RWB-1

CLOSET

105B

CPT-2

RWB-1

KITCHEN

107D

LVT-1

RWB-1

ROOM

107A

CPT-2

RWB-1

CLOSET

107B

CPT-2

RWB-1

CLOSET

108B

CPT-2

RWB-1

KITCHEN

108D

LVT-1

RWB-1

DINING

108C

LVT-1

RWB-1

CLOSET

106C

CPT-2

RWB-1

ROOM

106A

CPT-2

RWB-1

CLOSET

106B

CPT-2

RWB-1

CLOSET

104B

CPT-2

RWB-1

ROOM

104A

CPT-2

RWB-1

CLOSET

104C

CPT-2

RWB-1

KITCHEN

102D

LVT-1

RWB-1

DINING

102C

LVT-1

RWB-1

ROOM

102A

CPT-2

RWB-1

CLOSET

102B

CPT-2

RWB-1

STAIR

RSL-1/RSN-1

RWB-2

CHR-1

PNT-4

P N

T -4

P N

T -4

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101

RE: H6/I-101 RE: H6/I-101

101E

BATHROOM 107E

BATHROOM

UNISEX

UNISEX 113E

BATHROOM

119E

BATHROOM

120E

BATHROOM

114E

BATHROOM

108E

BATHROOM

102E

BATHROOM

P N

T -4

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

FRP-1F

R

P -1

FRP-1 1

1. NO SUBSTITUTIONS OF FINISHES ARE ALLOWED WITHOUT APPROVAL OF CONTRACTING OFFICIER'S REPRESENTATIVE.

2. FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS FOR INTERIOR FINISHES ARE TO BE IN ACCORDANCE WITH

APPLICABLE CODES.

3. FLOOR TRANSITIONS SHALL OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION, UNO. REFER TO FINISH SCHEDULE &

SHEET IN-501 FOR FLOOR TRANSITION DETAILS BY FLOOR TYPE.

4. FLOORING TRANSITIONS SHALL BE COMPLETELY FLUSH. FIELD VERIFY FLOOR SLAB AND NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE OF AREAS TO BE LEVELED BEFORE COMMENCING WORK. PROVIDE ADEQUATE FLOOR LEVELING MATERIAL TO MAINTAIN CONSISTENT LEVEL FLOOR SURFACE BETWEEN DIFFERENT FLOORING FINISH MATERIALS. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY IF EXCESSIVE FLOOR FLOAT IS REQUIRED.

5. TYPICAL FLOOR BASE SHALL BE RWB-1, UNO. REFER TO FINISH SCHEDULE & SHEET IN-501 FOR WALL BASE DETAILS.

6. SCHEDULED FLOOR FINISH TO RUN CONTINUOUSLY UNDERNEATH OPEN MILLWORK, UNO.

7. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISH INFORMATION.

8. REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL FINISH REQUIREMENTS, INCLUDING DIMENSIONS AND EXTENT OF

SPECIAL WALL FINISHES.

9. GYPSUM BOARD PARTITIONS SHALL BE FLOATED OUT TO MAINTAIN A SMOOTH, EVEN, CONSISTENT APPEARANCE IN ACCORDANCE WITH SPECIFICATION SECTION 092900. NOTICEABLE JOINTS OR TAPE LINES IN GYPSUM BOARD PARTITIONS WILL NOT BE ACCEPTABLE. REFER TO FINISH SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL WALL FINISH INFO.

10. PAINTED WALLS SHALL HAVE AN EVEN DEPTH OF COLOR AND REFLECTANCE. IF A PORTION OF A WALL IS REPAINTED AND

AN EVEN FINISH IS NOT ACHIEVED, THE ENTIRE WALL SHALL BE REPAINTED.

11. ACCESS PANELS, ELECTRICAL PANELS, AND OTHER UNFINISHED OR PRIME COATED ITEMS SHALL BE PAINTED TO MATCH

THE WALL OR CEILING.

12. TYPICAL WINDOW COVERING TO BE MECHOSHADE, REFER TO INTERIOR FINISH SCHEDULE FOR ADDITIONAL INFORMATION.

13. ELECTRICAL COMMUNICATION DEVICES AND COVER PLATES SHALL BE WHITE, UNO.

14. ALL WALLS AND CEILINGS SHALL RECEIVE PAINT COLOR, PNT-1, TYPICAL, UNO. ALLOW FOR PRIMER AND TWO TOPCOATS FOR PAINT APPLICATION OVER GYPSUM BOARD SURFACES WITH EG-SHEL FINISH, UNO BELOW. REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

15. UNLESS PAINT COLORS ARE INDICATED ON FINISH PLANS, PAINT SPECIFIC ROOMS AS FOLLOWS:

a. ALL WALLS IN DORM LIVING ROOMS AND ADJACENT VANITY AREA SHALL RECEIVE PNT-3 WITH EG-SHEL FINISH;

b. ALL DORM CLOSETS & SHOWER ROOMS SHALL BE TYPICAL PNT-1;

c. ALL GYP SURFACES IN RESTROOMS AND BATHROOMS TO RECEIVE EPOXY PAINT IN COLOR AS SCHEDULED OR

REFERENCED ABOVE

16. ALL CEILING MOUNTED DEVICES TO MATCH CEILING COLOR, INCLUDING DIFFUSERS.

17. ACCENT PAINT SHALL EXTEND HORIZONTALLY FROM INSIDE CORNER TO INSIDE CORNER ALONG WALL. CONTINUE ACCENT PAINT ACROSS FURR-DOWNS AND BULKHEADS ONLY IF THEY ARE IN THE SAME PLANE AS THE ACCENT WALL.

18. CAULKING AND SEALANT SHALL MATCH SURFACE TO WHICH IT IS APPLIED, UNO. SUBMIT COLOR CHART FOR ARCHITECT'S SELECTION. WHERE TWO DIFFERENT MATERIALS/COLORS ALIGN IN THE SAME PLANE, MATCH THE DARKER COLOR.

19. PAINT HOLLOW METAL DOORS SAME COLOR AS DOOR FRAME, TYPICAL, UNO. HOLLOW METAL FRAMES DOOR & WINDOW FRAMES, METAL DOORS AND RAILINGS PNT-2 SEMI-GLOSS, DIRECT-TO-METAL PAINT. REFER TO FINISH SCHEDULE &

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

20. ALL CORNER GUARDS SHALL BE WCG-1 4'-0" TALL & INSTALLED AT TOP OF WALL BASE AT LOCATIONS SHOWN ON FINISH PLANS. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION. WHERE CORNER GUARDS ARE INSTALLED AT

LOCATIONS WITH FRP, CORNER GUARD HEIGHT SHALL MATCH HEIGHT OF WALL PROTECTION.

21. WHERE FRP PANELS ARE REQUIRED TO BE GREATER THAN 48" HIGH, PANELS SHALL BE CUT IN FIELD & INSTALLED

VERTICALLY.

22. PAINT UNDERSIDE AND FACE OF ALL SOFFITS PNT-1 EG-SHEL FINISH.

23. ALL SHOWER RODS TO BE INSTALLED WITH CENTER OF ROD AT 79" A.F.F.

24. ALL COUNTERTOPS, WALL CAPS, & WINDOW SILLS SHALL BE QTZ-1, ALL MILLWORK SHALL BE STAINED WST-1. REFER TO

FINISH SCHEDULE FOR ADDITIONAL INFORMATION.

25. CAULKING AND SEALANT SHALL MATCH SURFACE TO WHICH IT IS APPLIED, UNO. WHERE TWO DIFFERENT

MATERIALS/COLORS ALIGN IN THE SAME PLANE, MATCH THE DARKER COLOR.

INTERIOR FINISH GENERAL NOTES

BATHROOM

101E

TIL-1

SSM-1

TIL-2

T

IL

-2

T

IL

-2

SSM-1

TIL-2

A9

I-501

TIL-2

TIL-2

QTZ-1 WALL CAP, 1"

OVERHANG

UNISEX

TIL-1

TWB-1

UNISEX

TIL-1

TWB-1

T

IL

-3

TIL-3

T

IL

-3

TIL-3

T

IL

-3

T

IL

-3

A9

I-501

A9

I-501

INTERIOR GRAPHIC LEGEND

ROOM NAME SYMBOL

ROOM NAME

FLOOR

BASE

FLOOR FINISH, RE: I-000

WALL BASE, RE: I-000

ROOM INFORMATION

CORNER GUARD

WALL PROTECTION AS INDICATED

ARROW INDICATES GRAIN/PATTERN DIRECTION OF FLOORING

SYMBOL DESCRIPTION

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

F

IL

E N

A M

E

U

SE

R N

A M

E

D A

T E S

T A

M P

REVISION HISTORY

AIR FORCE GLOBAL STRIKE COMMAND

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A u to d e sk

D o cs

/3

G

O -M a lm st ro m R e n o v a te

D o rm a n d

/3

G

O b -A

-R -C

E N

T R A L .r v t

/1

/2

:3

:3

P

M

I-101 09/16/2025

CJ

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

Author

ARCHITECTURAL - INTERIORS

FINISH PLAN - LEVEL 01

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

Designer

SCALE: 1/8" = 1'-0"D1

INTERIOR - OVERALL FINISH PLAN - LEVEL 01

KEYED NOTES 1

NUMBER DESCRIPTION

SCALE: 1/4" = 1'-0"H9

ENLARGED FINISH PLAN - SHARED

BATHROOM

SCALE: 1/4" = 1'-0"H6

ENLARGED FINISH PLAN - PUBLIC

RESTROOMS

TV/LOUNGE

CPT-1

RWB-1

LAUNDRY

RSF-1

INT-1

FOLDING

RSF-1

INT-1

LOBBY

TIL-1

TWB-1

PERSONAL

STORAGE

SEC-1

RWB-2

ELEC

SEC-1

RWB-2

JAN

RSF-1

RWB-2

STAIR

RSL-1/RSN-1

RWB-2

STAIR

RSL-1/RSN-1

RWB-1

ROOM

201A

CPT-2

RWB-1

ROOM

203A

CPT-2

RWB-1

ROOM

205A

CPT-2

RWB-1

ROOM

207A

CPT-2

RWB-1

ROOM

209A

CPT-2

RWB-1

ROOM

211A

CPT-2

RWB-1

ROOM

213A

CPT-2

RWB-1

ROOM

215A

CPT-2

RWB-1

ROOM

217A

CPT-2

RWB-1

ROOM

219A

CPT-2

RWB-1

ROOM

220A

CPT-2

RWB-1

ROOM

218A

CPT-2

RWB-1ROOM

216A

CPT-2

RWB-1

ROOM

214A

CPT-2

RWB-1

ROOM

208A

CPT-2

RWB-1ROOM

206A

CPT-2

RWB-1

ROOM

204A

CPT-2

RWB-1

ROOM

202A

CPT-2

RWB-1

CORRIDOR

CPT-1

RWB-1

CORRIDOR

CPT-1

RWB-1

KITCHEN

219D

LVT-1

RWB-1

KITCHEN

213D

LVT-1

RWB-1

KITCHEN

209C

LVT-1

RWB-1

KITCHEN

207D

LVT-1

RWB-1

KITCHEN

201D

LVT-1

RWB-1

KITCHEN

202D

LVT-1

RWB-1

KITCHEN

208D

LVT-1

RWB-1

KITCHEN

214D

LVT-1

RWB-1

KITCHEN

220D

LVT-1

RWB-1

CLOSET

201B

CPT-2

RWB-1

DINING

201C

LVT-1

RWB-1

CLOSET

203B

CPT-2

RWB-1

CLOSET

205B

CPT-2

RWB-1

CLOSET

203C

CPT-2

RWB-1

CLOSET

205C

CPT-2

RWB-1

DINING

207C

LVT-1

RWB-1

CLOSET

207B

CPT-2

RWB-1

CLOSET

202B

CPT-2

RWB-1

DINING

202C

LVT-1

RWB-1

CLOSET

204B

CPT-2

RWB-1

CLOSET

206B

CPT-2

RWB-1

CLOSET

204C

CPT-2

RWB-1

CLOSET

206C

CPT-2

RWB-1

DINING

208C

LVT-1

RWB-1

CLOSET

208B

CPT-2

RWB-1

CLOSET

214B

CPT-2

RWB-1

DINING

214C

LVT-1

RWB-1

CLOSET

216B

CPT-2

RWB-1

CLOSET

218B

CPT-2

RWB-1

CLOSET

216C

CPT-2

RWB-1

CLOSET

218C

CPT-2

RWB-1

DINING

220C

LVT-1

RWB-1

CLOSET

220B

CPT-2

RWB-1

CLOSET

209B

CPT-2

RWB-1

CLOSET

211B

CPT-2

RWB-1

CLOSET

213B

CPT-2

RWB-1

DINING

213C

LVT-1

RWB-1

CLOSET

215B

CPT-2

RWB-1

CLOSET

217D

CPT-2

RWB-1

CLOSET

215C

CPT-2

RWB-1

CLOSET

217C

CPT-2

RWB-1

DINING

219C

LVT-1

RWB-1

CLOSET

219B

CPT-2

RWB-1

C H

R -1

P N

T -4

P N

T -4

FRP-1

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101

201E

BATHROOM

207E

BATHROOM

209E

BATHROOM

213E

BATHROOM

219E

BATHROOM

220E

BATHROOM

214E

BATHROOM

208E

BATHROOM

202E

BATHROOM

P N

T -4

RE: H9/I-102

CORR

209D

LVT-1

RWB-1

CHR-1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

CHR-1

CHR-1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

CHR-1

PNT-4

F R

P -1

FRP-1

1. NO SUBSTITUTIONS OF FINISHES ARE ALLOWED WITHOUT APPROVAL OF CONTRACTING OFFICIER'S REPRESENTATIVE.

2. FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS FOR INTERIOR FINISHES ARE TO BE IN ACCORDANCE WITH

APPLICABLE CODES.

3. FLOOR TRANSITIONS SHALL OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION, UNO. REFER TO FINISH SCHEDULE &

SHEET IN-501 FOR FLOOR TRANSITION DETAILS BY FLOOR TYPE.

4. FLOORING TRANSITIONS SHALL BE COMPLETELY FLUSH. FIELD VERIFY FLOOR SLAB AND NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE OF AREAS TO BE LEVELED BEFORE COMMENCING WORK. PROVIDE ADEQUATE FLOOR LEVELING MATERIAL TO MAINTAIN CONSISTENT LEVEL FLOOR SURFACE BETWEEN DIFFERENT FLOORING FINISH MATERIALS. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY IF EXCESSIVE FLOOR FLOAT IS REQUIRED.

5. TYPICAL FLOOR BASE SHALL BE RWB-1, UNO. REFER TO FINISH SCHEDULE & SHEET IN-501 FOR WALL BASE DETAILS.

6. SCHEDULED FLOOR FINISH TO RUN CONTINUOUSLY UNDERNEATH OPEN MILLWORK, UNO.

7. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISH INFORMATION.

8. REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL FINISH REQUIREMENTS, INCLUDING DIMENSIONS AND EXTENT OF

SPECIAL WALL FINISHES.

9. GYPSUM BOARD PARTITIONS SHALL BE FLOATED OUT TO MAINTAIN A SMOOTH, EVEN, CONSISTENT APPEARANCE IN ACCORDANCE WITH SPECIFICATION SECTION 092900. NOTICEABLE JOINTS OR TAPE LINES IN GYPSUM BOARD PARTITIONS WILL NOT BE ACCEPTABLE. REFER TO FINISH SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL WALL FINISH INFO.

10. PAINTED WALLS SHALL HAVE AN EVEN DEPTH OF COLOR AND REFLECTANCE. IF A PORTION OF A WALL IS REPAINTED AND

AN EVEN FINISH IS NOT ACHIEVED, THE ENTIRE WALL SHALL BE REPAINTED.

11. ACCESS PANELS, ELECTRICAL PANELS, AND OTHER UNFINISHED OR PRIME COATED ITEMS SHALL BE PAINTED TO MATCH

THE WALL OR CEILING.

12. TYPICAL WINDOW COVERING TO BE MECHOSHADE, REFER TO INTERIOR FINISH SCHEDULE FOR ADDITIONAL INFORMATION.

13. ELECTRICAL COMMUNICATION DEVICES AND COVER PLATES SHALL BE WHITE, UNO.

14. ALL WALLS AND CEILINGS SHALL RECEIVE PAINT COLOR, PNT-1, TYPICAL, UNO. ALLOW FOR PRIMER AND TWO TOPCOATS FOR PAINT APPLICATION OVER GYPSUM BOARD SURFACES WITH EG-SHEL FINISH, UNO BELOW. REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

15. UNLESS PAINT COLORS ARE INDICATED ON FINISH PLANS, PAINT SPECIFIC ROOMS AS FOLLOWS:

a. ALL WALLS IN DORM LIVING ROOMS AND ADJACENT VANITY AREA SHALL RECEIVE PNT-3 WITH EG-SHEL FINISH;

b. ALL DORM CLOSETS & SHOWER ROOMS SHALL BE TYPICAL PNT-1;

c. ALL GYP SURFACES IN RESTROOMS AND BATHROOMS TO RECEIVE EPOXY PAINT IN COLOR AS SCHEDULED OR

REFERENCED ABOVE

16. ALL CEILING MOUNTED DEVICES TO MATCH CEILING COLOR, INCLUDING DIFFUSERS.

17. ACCENT PAINT SHALL EXTEND HORIZONTALLY FROM INSIDE CORNER TO INSIDE CORNER ALONG WALL. CONTINUE ACCENT PAINT ACROSS FURR-DOWNS AND BULKHEADS ONLY IF THEY ARE IN THE SAME PLANE AS THE ACCENT WALL.

18. CAULKING AND SEALANT SHALL MATCH SURFACE TO WHICH IT IS APPLIED, UNO. SUBMIT COLOR CHART FOR ARCHITECT'S SELECTION. WHERE TWO DIFFERENT MATERIALS/COLORS ALIGN IN THE SAME PLANE, MATCH THE DARKER COLOR.

19. PAINT HOLLOW METAL DOORS SAME COLOR AS DOOR FRAME, TYPICAL, UNO. HOLLOW METAL FRAMES DOOR & WINDOW FRAMES, METAL DOORS AND RAILINGS PNT-2 SEMI-GLOSS, DIRECT-TO-METAL PAINT. REFER TO FINISH SCHEDULE &

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

20. ALL CORNER GUARDS SHALL BE WCG-1 4'-0" TALL & INSTALLED AT TOP OF WALL BASE AT LOCATIONS SHOWN ON FINISH PLANS. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION. WHERE CORNER GUARDS ARE INSTALLED AT

LOCATIONS WITH FRP, CORNER GUARD HEIGHT SHALL MATCH HEIGHT OF WALL PROTECTION.

21. WHERE FRP PANELS ARE REQUIRED TO BE GREATER THAN 48" HIGH, PANELS SHALL BE CUT IN FIELD & INSTALLED

VERTICALLY.

22. PAINT UNDERSIDE AND FACE OF ALL SOFFITS PNT-1 EG-SHEL FINISH.

23. ALL SHOWER RODS TO BE INSTALLED WITH CENTER OF ROD AT 79" A.F.F.

24. ALL COUNTERTOPS, WALL CAPS, & WINDOW SILLS SHALL BE QTZ-1, ALL MILLWORK SHALL BE STAINED WST-1. REFER TO

FINISH SCHEDULE FOR ADDITIONAL INFORMATION.

25. CAULKING AND SEALANT SHALL MATCH SURFACE TO WHICH IT IS APPLIED, UNO. WHERE TWO DIFFERENT

MATERIALS/COLORS ALIGN IN THE SAME PLANE, MATCH THE DARKER COLOR.

INTERIOR FINISH GENERAL NOTES

INTERIOR GRAPHIC LEGEND

ROOM NAME SYMBOL

ROOM NAME

FLOOR

BASE

FLOOR FINISH, RE: I-000

WALL BASE, RE: I-000

ROOM INFORMATION

CORNER GUARD

WALL PROTECTION AS INDICATED

ARROW INDICATES GRAIN/PATTERN DIRECTION OF FLOORING

SYMBOL DESCRIPTION

BATHROOM

209E

TIL-1

SSM-1

SSM-1

TIL-2

TIL-2

T

IL

-2 T

IL

-2

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

F

IL

E N

A M

E

U

SE

R N

A M

E

D A

T E S

T A

M P

REVISION HISTORY

AIR FORCE GLOBAL STRIKE COMMAND

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A u to d e sk

D o cs

/3

G

O -M a lm st ro m R e n o v a te

D o rm a n d

/3

G

O b -A

-R -C

E N

T R A L .r v t

/1

/2

:3

:3

P

M

I-102 09/16/2025

CJ

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

Author

ARCHITECTURAL - INTERIORS

FINISH PLAN - LEVEL 02

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

Designer

SCALE: 1/8" = 1'-0"D1

INTERIOR - OVERALL FINISH PLAN - LEVEL 02

KEYED NOTES 1

NUMBER DESCRIPTION

SCALE: 1/4" = 1'-0"H9

ENLARGED FINISH PLAN - SHARED BATHROOM

TV/LOUNGE

CPT-1

RWB-1

PERSONAL

STORAGE

SEC-1

RWB-2

LOBBY

TIL-1

TWB-1

LAUNDRY

RSF-1

INT-1

FOLDING

RSF-1

INT-1

ELEC

SEC-1

RWB-2

STAIR

RSL-/RSN-1

RWB-2

JAN

RSF-1

RWB-2

STAIR

RSL-1/RSN-1

RWB-2

STAIR

RSL-1/RSN-1

RWB-2

ROOM

301A

CPT-2

RWB-1

ROOM

303A

CPT-2

RWB-1

ROOM

305A

CPT-2

RWB-1

ROOM

307A

CPT-2

RWB-1

KITCHEN

307D

LVT-1

RWB-1

KITCHEN

301D

LVT-1

RWB-1

KITCHEN

302D

LVT-1

RWB-1

ROOM

302A

CPT-2

RWB-1

ROOM

304A

CPT-2

RWB-1

ROOM

306A

CPT-2

RWB-1

ROOM

308A

CPT-2

RWB-1

KITCHEN

308D

LVT-1

RWB-1

ROOM

309A

CPT-2

RWB-1

ROOM

311A

CPT-2

RWB-1

ROOM

313A

CPT-2

RWB-1

ROOM

315A

CPT-2

RWB-1

ROOM

317A

CPT-2

RWB-1

ROOM

319A

CPT-2

RWB-1

KITCHEN

319D

LVT-1

RWB-2

KITCHEN

313D

LVT-1

RWB-1

KITCHEN

309C

LVT-1

RWB-1

ROOM

314A

CPT-2

RWB-1

ROOM

316A

CPT-2

RWB-1

ROOM

318A

CPT-2

RWB-1

ROOM

320A

CPT-2

RWB-1

KITCHEN

320D

LVT-1

RWB-1

KITCHEN

314D

LVT-1

RWB-1

CLOSET

301B

CPT-2

RWB-1

DINING

301C

LVT-1

RWB-1

CLOSET

303C

CPT-2

RWB-1

CLOSET

305C

CPT-2

RWB-1

CLOSET

303B

CPT-2

RWB-1

CLOSET

305B

CPT-2

RWB-1

DINING

307C

LVT-1

RWB-1

CLOSET

307B

CPT-2

RWB-1

CLOSET

309B

CPT-2

RWB-1

CLOSET

311B

CPT-2

RWB-1

CLOSET

313B

CPT-2

RWB-1

DINING

313C

LVT-1

RWB-1

CLOSET

315C

CPT-2

RWB-1

CLOSET

317C

CPT-2

RWB-1

CLOSET

315B

CPT-2

RWB-1

CLOSET

317D

CPT-2

RWB-1

DINING

319C

LVT-1

RWB-2

CLOSET

319B

CPT-2

RWB-1

CLOSET

320B

CPT-2

RWB-1

DINING

320C

LVT-1

RWB-1

CLOSET

318C

CPT-2

RWB-1

CLOSET

316C

CPT-2

RWB-1

CLOSET

318B

CPT-2

RWB-1

CLOSET

316B

CPT-2

RWB-1

DINING

314C

LVT-1

RWB-1

CLOSET

314B

CPT-2

RWB-1

DINING

302C

LVT-1

RWB-1

CLOSET

302B

CPT-2

RWB-1

CLOSET

304B

CPT-2

RWB-1

CLOSET

306B

CPT-2

RWB-1

CLOSET

304C

CPT-2

RWB-1

CLOSET

306C

CPT-2

RWB-1

DINING

308C

LVT-1

RWB-1

CLOSET

308B

CPT-2

RWB-1

C H

R -1

P N

T -4

P N

T -4

PNT-4

CORRIDOR

CPT-1

RWB-1

CORRIDOR

CPT-1

RWB-1

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101

RE: H9/I-101 RE: H9/I-101

RE: H9/I-101

301E

BATHROOM

307E

BATHROOM

309E

BATHROOM

313E

BATHROOM

319E

BATHROOM

320E

BATHROOM

314E

BATHROOM

308E

BATHROOM

302E

BATHROOM

P N

T -4

CORR

309D

LVT-1

RWB-1

RE: H9/I-102

CHR-1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

CHR-1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

C H

R -1

CHR-1

CHR-1

C H

R -1

CHR-1

FRP-1F

R

P -1

FRP-1

1. NO SUBSTITUTIONS OF FINISHES ARE ALLOWED WITHOUT APPROVAL OF CONTRACTING OFFICIER'S REPRESENTATIVE.

2. FLAME SPREAD AND SMOKE DEVELOPMENT RATINGS FOR INTERIOR FINISHES ARE TO BE IN ACCORDANCE WITH

APPLICABLE CODES.

3. FLOOR TRANSITIONS SHALL OCCUR AT CENTERLINE OF DOOR IN CLOSED POSITION, UNO. REFER TO FINISH SCHEDULE &

SHEET IN-501 FOR FLOOR TRANSITION DETAILS BY FLOOR TYPE.

4. FLOORING TRANSITIONS SHALL BE COMPLETELY FLUSH. FIELD VERIFY FLOOR SLAB AND NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE OF AREAS TO BE LEVELED BEFORE COMMENCING WORK. PROVIDE ADEQUATE FLOOR LEVELING MATERIAL TO MAINTAIN CONSISTENT LEVEL FLOOR SURFACE BETWEEN DIFFERENT FLOORING FINISH MATERIALS. NOTIFY CONTRACTING OFFICER'S REPRESENTATIVE IMMEDIATELY IF EXCESSIVE FLOOR FLOAT IS REQUIRED.

5. TYPICAL FLOOR BASE SHALL BE RWB-1, UNO. REFER TO FINISH SCHEDULE & SHEET IN-501 FOR WALL BASE DETAILS.

6. SCHEDULED FLOOR FINISH TO RUN CONTINUOUSLY UNDERNEATH OPEN MILLWORK, UNO.

7. REFER TO REFLECTED CEILING PLANS FOR CEILING FINISH INFORMATION.

8. REFER TO INTERIOR ELEVATIONS FOR ADDITIONAL FINISH REQUIREMENTS, INCLUDING DIMENSIONS AND EXTENT OF

SPECIAL WALL FINISHES.

9. GYPSUM BOARD PARTITIONS SHALL BE FLOATED OUT TO MAINTAIN A SMOOTH, EVEN, CONSISTENT APPEARANCE IN ACCORDANCE WITH SPECIFICATION SECTION 092900. NOTICEABLE JOINTS OR TAPE LINES IN GYPSUM BOARD PARTITIONS WILL NOT BE ACCEPTABLE. REFER TO FINISH SCHEDULE AND SPECIFICATIONS FOR ADDITIONAL WALL FINISH INFO.

10. PAINTED WALLS SHALL HAVE AN EVEN DEPTH OF COLOR AND REFLECTANCE. IF A PORTION OF A WALL IS REPAINTED AND

AN EVEN FINISH IS NOT ACHIEVED, THE ENTIRE WALL SHALL BE REPAINTED.

11. ACCESS PANELS, ELECTRICAL PANELS, AND OTHER UNFINISHED OR PRIME COATED ITEMS SHALL BE PAINTED TO MATCH

THE WALL OR CEILING.

12. TYPICAL WINDOW COVERING TO BE MECHOSHADE, REFER TO INTERIOR FINISH SCHEDULE FOR ADDITIONAL INFORMATION.

13. ELECTRICAL COMMUNICATION DEVICES AND COVER PLATES SHALL BE WHITE, UNO.

14. ALL WALLS AND CEILINGS SHALL RECEIVE PAINT COLOR, PNT-1, TYPICAL, UNO. ALLOW FOR PRIMER AND TWO TOPCOATS FOR PAINT APPLICATION OVER GYPSUM BOARD SURFACES WITH EG-SHEL FINISH, UNO BELOW. REFER TO SPECIFICATIONS

FOR ADDITIONAL INFORMATION.

15. UNLESS PAINT COLORS ARE INDICATED ON FINISH PLANS, PAINT SPECIFIC ROOMS AS FOLLOWS:

a. ALL WALLS IN DORM LIVING ROOMS AND ADJACENT VANITY AREA SHALL RECEIVE PNT-3 WITH EG-SHEL FINISH;

b. ALL DORM CLOSETS & SHOWER ROOMS SHALL BE TYPICAL PNT-1;

c. ALL GYP SURFACES IN RESTROOMS AND BATHROOMS TO RECEIVE EPOXY PAINT IN COLOR AS SCHEDULED OR

REFERENCED ABOVE

16. ALL CEILING MOUNTED DEVICES TO MATCH CEILING COLOR, INCLUDING DIFFUSERS.

17. ACCENT PAINT SHALL EXTEND HORIZONTALLY FROM INSIDE CORNER TO INSIDE CORNER ALONG WALL. CONTINUE ACCENT PAINT ACROSS FURR-DOWNS AND BULKHEADS ONLY IF THEY ARE IN THE SAME PLANE AS THE ACCENT WALL.

18. CAULKING AND SEALANT SHALL MATCH SURFACE TO WHICH IT IS APPLIED, UNO. SUBMIT COLOR CHART FOR ARCHITECT'S SELECTION. WHERE TWO DIFFERENT MATERIALS/COLORS ALIGN IN THE SAME PLANE, MATCH THE DARKER COLOR.

19. PAINT HOLLOW METAL DOORS SAME COLOR AS DOOR FRAME, TYPICAL, UNO. HOLLOW METAL FRAMES DOOR & WINDOW FRAMES, METAL DOORS AND RAILINGS PNT-2 SEMI-GLOSS, DIRECT-TO-METAL PAINT. REFER TO FINISH SCHEDULE &

SPECIFICATIONS FOR ADDITIONAL INFORMATION.

20. ALL CORNER GUARDS SHALL BE WCG-1 4'-0" TALL & INSTALLED AT TOP OF WALL BASE AT LOCATIONS SHOWN ON FINISH PLANS. REFER TO FINISH SCHEDULE FOR ADDITIONAL INFORMATION. WHERE CORNER GUARDS ARE INSTALLED AT

LOCATIONS WITH FRP, CORNER GUARD HEIGHT SHALL MATCH HEIGHT OF WALL PROTECTION.

21. WHERE FRP PANELS ARE REQUIRED TO BE GREATER THAN 48" HIGH, PANELS SHALL BE CUT IN FIELD & INSTALLED

VERTICALLY.

22. PAINT UNDERSIDE AND FACE OF ALL SOFFITS PNT-1 EG-SHEL FINISH.

23. ALL SHOWER RODS TO BE INSTALLED WITH CENTER OF ROD AT 79" A.F.F.

24. ALL COUNTERTOPS, WALL CAPS, & WINDOW SILLS SHALL BE QTZ-1, ALL MILLWORK SHALL BE STAINED WST-1. REFER TO

FINISH SCHEDULE FOR ADDITIONAL INFORMATION.

25. CAULKING AND SEALANT SHALL MATCH SURFACE TO WHICH IT IS APPLIED, UNO. WHERE TWO DIFFERENT

MATERIALS/COLORS ALIGN IN THE SAME PLANE, MATCH THE DARKER COLOR.

INTERIOR FINISH GENERAL NOTES

INTERIOR GRAPHIC LEGEND

ROOM NAME SYMBOL

ROOM NAME

FLOOR

BASE

FLOOR FINISH, RE: I-000

WALL BASE, RE: I-000

ROOM INFORMATION

CORNER GUARD

WALL PROTECTION AS INDICATED

ARROW INDICATES GRAIN/PATTERN DIRECTION OF FLOORING

SYMBOL DESCRIPTION

DESCRIPTIONREVISION DATE

IFB

CHECKED BY:

DRAWN BY:

PROJECT NO: DATE: SHEET ID.

F

IL

E N

A M

E

U

SE

R N

A M

E

D A

T E S

T A

M P

REVISION HISTORY

AIR FORCE GLOBAL STRIKE COMMAND

MALMSTROM AIR FORCE BASE

GREAT FALLS, MONTANA

341ST MISSLE WING

341ST CIVIL ENGINEERING SQUADRON

ENGINEERING TECHNICAL SUPPORT (CEN)

SHEET NO.

SCALE:

SIZE: 30" X 42"

DESIGNED BY:

CONTRACT NO:

TASK ORDER NO:

B

C

D

E

F

G

H

2 3 4 5 6 7 8 9 10

J

K

A

# of 156FA4626-23-D-0007

FA4626-24-F-0044

A u to d e sk

D o cs

/3

G

O -M a lm st ro m R e n o v a te

D o rm a n d

/3

G

O b -A

-R -C

E N

T R A L .r v t

/1

/2

:3

:3

P

M

I-103 09/16/2025

CJ

NZAS 10-1011 (PAGE/IMEG JV:41G023261)

Author

ARCHITECTURAL - INTERIORS

FINISH PLAN - LEVEL 03

REPAIR DORMITORY 742

331 Dormitory

Court; Great Falls, MT 59405

Designer

SCALE: 1/8" = 1'-0"D1

INTERIOR - OVERALL FINISH PLAN - LEVEL 03

KEYED NOTES 1

A-101 - ARCHITECTURAL - FLOOR PLAN - LEVEL 01
A-102 - ARCHITECTURAL - FLOOR PLAN - LEVEL 02
A-103 - ARCHITECTURAL - FLOOR PLAN - LEVEL 03
A-410 - ARCHITECTURAL - ENLARGED FLOOR PLANS AND RCP

File details come from the government source that posted it. Updated .