Attachment 14 - B2405_2406 DoD SAFE Memo.pdf

PDF 104 KB Posted

Attached to
Repair HVAC Dormitory Building 2405 and 2406 at Joint Base Charleston -Weapons Station, Goose Creek, South Carolina
Solicitation number
FA441820R0016
Issued by

About this file

This memorandum and solicitation provide details for a federal contract opportunity to repair HVAC systems at dormitory buildings 2405 and 2406 at Joint Base Charleston - Weapons Station in Goose Creek, South Carolina. The scope of work includes exterior wall repairs and sealant replacement, metal roof repairs, mechanical equipment removal and replacement, and asbestos/lead surveys. New variable air volume air handling units, supply fans, energy recovery modules, exhaust fans, filters and associated ductwork and piping will be installed. Fire dampers, support beams, columns and base plates will also be addressed. The solicitation was issued by the Department of the Air Force Air Mobility Command and responses are due by the date specified in the Standard Form 1449 that is part of the solicitation package.

View the file

Other files

File Type Posted
Attachment 17 - Questions and Answers 20R0010_21R0002 Amendment 6 Fire Protection 20201203.pdf PDF
Amendment 06 - FA441821R00020006.pdf PDF
Attachment 16 - W401-W404 Elevations FA441820R0010_21R0002 20201203.pdf PDF
Amendment 05 FA441821R00020005 SF 30.pdf PDF
Attachment 15 - BEQ SITE VISIT SIGN IN SHEET 18.Nov.20.pdf PDF
Amendment 04 - FA441821R00020004 SF 30 111920.pdf PDF
Attachment 11 - New JBC Section 28 31 76 FINAL 2405 2406 Oct 2020.pdf PDF
Attachment 12 - Joint Base Charleston - Barracks Building 2408 - Rev-02 - 10-28-2020.pdf PDF
Attachment 10 - Addendum 1 2020-11-10.pdf PDF
Amendment 03 to FA441821R00020003 20201110.pdf PDF
Attachment 13 - New Section 09 29 00 gypsum board.pdf PDF
Attachment 5 - AF 66-Revised Submittal Register.xlsx XLSX spreadsheet
Amendment 02 FA441821R00020002 SF 30.pdf PDF
Attachment 3 - Green Procurement Form.pdf PDF
Attachment 4 - HVAC Plans duct dimensions.pdf PDF
Amendment 02 FA441821R00020002 SF 30.pdf PDF
Attachment 7 - Attic Sprinkler Iso Vlv Loc.pdf PDF
Attachment 8 - SIGN-IN SHEET for 20200924 (filled in).pdf PDF
Attachment 9 - Pre-Bid Questions for B2405 B2406 - November 3 2020 11022020.pdf PDF
Amendment 01 - FA441821R00020001 SF 30.pdf PDF
Attachment 5 - Submittal Register.pdf PDF
Attachment 3 - Performance Time-B2405-2406.pdf PDF
FA441820R0016 20200914 Solicitation.pdf PDF
Attachment 4 - Green Procurement Form.pdf PDF
Attachment 6 - WD Berkeley County 14 Aug 2020.pdf PDF
Attachment 1 - Drawings for B2405 and B2406.pdf PDF
Attachment 2 - SPECS Final 2020 06 15.pdf PDF
Show all 27

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

As-Built Drawings for Buildings 2405 and 2406 Memorandum

Project: DKGV 18-1073189

RPR HVAC, DORMITORY B.2405/B.2406 (NNPTC)

Joint Base Charleston -

WS South Carolina

18 November 2020

1. Email Byron Faison at byron.faison@us.af.mil for DoD SAFE link with Attachment 14 – As Built

Drawings for DORMITORY B.2405 and B.2406.

2. On these As-Built drawings, building 2405 is labeled number 7 and building 2406 is labeled number 6. These drawings are from when the BEQ/dormitories were originally built. The buildings used to be numbered differently.

mailto:byron.faison@us.af.mil

File details come from the government source that posted it. Updated .