This file is a template and instructions document for the Construction Environmental, Safety & Health Certification (CESHC), required for all construction projects at the Department of Energy's Fermi National Accelerator Laboratory (Fermilab).

The CESHC must be completed by construction subcontractors for every project regardless of size or complexity. Prime subcontractors may either flow down this requirement to each subcontractor individually or serve as a single control point with all subcontractors operating under one CESHC. The completed certification must be submitted to the FermiForward Procurement Office for review and concurrence by FermiForward's Environmental, Safety & Health (ES&H) and Project Management teams before work commences. The document is intended as a living document that may be updated throughout the project as conditions change or additional information becomes available. All sections require completion, with "N/A" entered for non-applicable items. Subcontractors must acknowledge compliance with Title 10, Code of Federal Regulations, Part 851 (Worker Safety and Health Program), which is mandatory for all work performed at the Fermilab site. The CESHC requires identification of occupational medicine requirements, including medical surveillance needs for employees working on-site for 30 eight-hour days within a 12-month period or enrolled in federally required exposure monitoring programs (hearing conservation, respiratory protection, lead exposure, DOT/commercial vehicle, blood lead, and substance abuse testing). Subcontractors must designate an occupational medicine provider from five FermiForward-identified medical facilities located in the Fermilab area near Aurora, Geneva, Batavia, and surrounding communities, or identify an alternate facility with supporting documentation.

View the file

Other files

File Type Posted
Amendment 02 RFP ISD-378581-RO.pdf PDF
Exhibit B Rev 1 - SOW updated 3-31-26 -Lab C.docx DOCX document
Exhibit A Rev 1 - Drawings Lab C redacted JP 3-31-26.pdf PDF
Exhibit C Rev 1 - 010010 3-31-26 Updated JP.pdf PDF
Amendment 01 RFP ISD-378581-RO.pdf PDF
Exhibit T - Proposal Form ISD-371462-RO Cross Gallery Southwest Annex Refresh Project.pdf PDF
Exhibit F - 013300_Submittals_FermiForward.pdf PDF
Exhibit M - SF1413.pdf PDF
Exhibit A - SOW.pdf PDF
Exhibit B - Drawings.pdf PDF
Exhibit C - SECTION_230529_-_HANGERS_AND_SUPPORTS_FOR_HVAC_PIPING_AND_EQUIPMENT.pdf PDF
Exhibit E - 013100_ESH_Requirements.pdf PDF
Exhibit I - 2025 Construction Insurance Requirements.pdf PDF
Exhibit L - Bond Performance FL-40.pdf PDF
Exhibit N - Fermilab Subcontractor Safety Information Questionnaire.pdf PDF
Exhibit P - SARC_Subcontractor Annual RepsCerts.pdf PDF
Exhibit D - 010010 - General Requirements.pdf PDF
Exhibit J - Bond Bid FL-41.pdf PDF
Exhibit K - Bond Payment FL-42.pdf PDF
Exhibit R - Davis Bacon Wage Rates General Decision IL20260008 Mod 1.txt TXT text file
1.0 RFP ISD-378581-RO.pdf PDF
Exhibit G - 014100_Quality_Requirements.pdf PDF
Exhibit H - FFDG General Terms and Conditions for Construction (08.2025).pdf PDF
Exhibit Q - PUR-466_Proposal Certifications.pdf PDF
Exhibit S - Sample Subcontract.pdf PDF
Show all 25

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

m.

ATTACHMENT C – Construction Environmental, Safety, & Health Certification (CESHC)

INSTRUCTIONS

This Construction Environmental, Safety & Health Certification (CESHC) is required for each construction project at DOE’s Fermi National Accelerator Laboratory site (Fermilab). See Technical Specification 013100 for further information.

This document is a template for the CESHC designed to assist construction subcontractors in describing project conditions and developing project-specific hazards and controls information.

The CESHC template is available in electronic format to facilitate editing.

The prime subcontractor may either flow down this requirement to each of its subcontractors; or serve as a control and coordination point, requiring all subcontractors’ activities to be conducted under the prime subcontractor’s solitary CESHC.

Subcontractors must submit the completed CESHC to the FermiForward Procurement Office, which will distribute the document for review and concurrence by the FermiForward ES&H and Project Management teams prior to work commencing. The CESHC is intended to be a living document, which may be updated as necessary throughout a project as information changes or as the project progresses (e.g. – as additional Task/trade Hazard Analyses are developed, subcontractors added, etc.).

All of the sections in are required to be completed for each construction project, regardless of the size or complexity. Enter information in all of the fill-in blocks that are applicable. For those that are not applicable, enter “N/A” or other suitable explanation.

10 CFR 851 Acknowledgement

Because Fermilab is a Department of Energy site, your company must meet the Department of Energy requirements of Title 10, Code of Federal Regulations, Part 851, “Worker Safety and Health Program” (Link to 10 CFR 851). It is your responsibility to ensure you have read and understand the actual regulatory requirements. Specify medical surveillance and qualifications. This may include Occupational exposure monitoring.

https://www.gpo.gov/fdsys/granule/CFR-2012-title10-vol4/CFR-2012-title10-vol4-part851

Construction Environmental, Safety & Health Certification (CESHC)

ACKNOWLEDGMENT of 10 CFR 851

As a subcontractor to FermiForward, while your workers are physically located at Fermilab you must meet the requirements of Title 10, Code of Federal Regulations, “Energy”, Part 851, “Worker Safety and Health Program” (10 CFR 851). As such, you must be aware of, and comply with, the requirements of this regulation. (Link to 10 CFR 851)

Acknowledgment I, (the author of this CEHSC), certify that that I have read the requirements of 10 CFR 851 and attest that my firm and its sub-tier contractors will comply with the requirements of 10 CFR 851.

Yes No

MEDICAL SURVEILLANCE AND

QUALIFICATION

Occupational Medicine Will you have any employees that will work on-site at Fermilab for 30, eight-hour days in a 12-month period, or are enrolled for any length of time in a medical or exposure monitoring program required by federal, state, or local regulations (including hearing conservation, respiratory protection, lead exposure)?

Yes No

If yes, you will need to:

1. Comply with the occupational medicine requirements of 10 CFR 851, Appendix A

2. Provide your occupational medicine provider contact information

Clinic Information Clinic Name & Address: Enter telephone number: Enter e-mail address: (Optional)

Required Medical Surveillance Task-specific medical testing

DOT/Commercial Vehicle Blood Lead Hearing Conservation Respirator User Fit for Duty Other(s) List other(s) Substance Abuse Testing

List specific task(s) requiring medical surveillance:

Signature (Subcontractor) Dated Signature

(FermiForward) Dated https://www.gpo.gov/fdsys/granule/CFR-2012-title10-vol4/CFR-2012-title10-vol4-part851

FermiForward has identified five medical facilities. Please highlight the facility to be used or identify and provide a map of an alternate selected place. Annotate address for designated facility.