This is a Florida Department of Environmental Protection (FDEP) exemption verification letter dated July 7, 2026, issued to Florida Keys Electric Cooperative Association, Inc. (FKEC) for the Vaca Cut Aerial Cable project located in Marathon, Monroe County, Florida. The project involves installation of 590 linear feet of 144-strand All Dielectric Self-Supporting (ADSS) fiber optic cable overhead transmission line along the Vaca Cut Bridge, spanning between existing poles C5-1297 (milepost 5.077) and C5-1296 (milepost 5.180) at 11710 Overseas Highway. The cable installation will utilize industry-standard safe work practices and National Electric Safety Code guidelines, with fiber dispensed from a truck-mounted reel with friction brake assembly and handline securing to prevent contact with water or channel floor. The project includes cross-sections, profile views, and plan drawings showing the cable routing over Class III waters on sovereign submerged lands owned by the Board of Trustees of the Internal Improvement Trust Fund.
The regulatory review verified that the activity qualifies for exemption under Chapter 62-330.051(14)(a), Florida Administrative Code, from needing a regulatory permit under Part IV of Chapter 373 of the Florida Statutes. The proprietary review granted a Letter of Consent under Section 253.77, Florida Statutes, authorizing construction and use on specified sovereign submerged lands, contingent upon FKEC maintaining satisfactory evidence of sufficient upland interest and complying with special consent conditions including indemnification of the Board of Trustees and the State of Florida from all claims arising from the authorization or use of the structure. However, the federal review determined that the proposed activity does not qualify for Federal authorization pursuant to the State Programmatic General Permit, requiring FKEC to apply separately to the U.S. Army Corps of Engineers (Jacksonville District) using Form ENG 4345 for a Section 10 Rivers and Harbor Act and Section 404 Clean Water Act permit before commencing work.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
www.floridadep.gov
FLORIDA DEPARTMENT OF
Environmental Protection Southeast District
3301 Gun Club Road, MSC 7210-1
West Palm Beach, FL 33406
561-681-6600
Ron DeSantis Governor
Jay Collins
Lt. Governor
Alexis A. Lambert
Secretary
July 7, 2026
Sara Hamilton
PO Box #377
Tavernier, Florida 33070
Sent via e-mail: Sara.hamilton@fkec.com
Re: File No.: 44-0470245-001-EE
File Name: FKEC Vaca Cut Aerial Cable
Dear Ms. Hamilton:
On March 26, 2026, we received your request for verification of exemption to install 590 linear feet of 144 strand ADSS fiber optic cable overhead transmission line along the Vaca Cut Bridge.
The project is located over the Vaca Cut, Class III Waters, adjacent to 11710 Overseas Highway, Marathon (Section 05, Township 66 South, Range 33 East), in Monroe County (Latitude N 24°
43' 50.5423", Longitude W 81° 1' 46.1457").
Your request has been reviewed to determine whether it qualifies for (1) regulatory exemption,
(2) proprietary authorization (related to state-owned submerged lands), and (3) federal approval that may be necessary for work in wetlands or waters of the United States.
Your project did not qualify for the federal authorization of this verification request. Additional authorization must be obtained prior to commencement of the proposed activity. This letter does not relieve you from the responsibility of obtaining other federal, state, or local authorizations that may be required for the activity. Please refer to the specific section(s) dealing with that portion of the review below for advice on how to proceed.
If you change the project from what you submitted, the authorization(s) granted may no longer be valid at the time of commencement of the project. Please contact us prior to beginning your project if you wish to make any changes.
If you have any questions regarding this matter, please contact Amber Maier at the letterhead address or at Amber.Maier@FloridaDEP.gov.
EXHIBIT E
http://www.dep.state.fl.us/ mailto:Sara.hamilton@fkec.com mailto:Amber.Maier@FloridaDEP.gov
Project No.: 44-0470245-001-EE
Project Name: FKEC Vaca Cut Aerial Cable
1. Regulatory Review – VERIFIED
Based on the information submitted, the Department has verified that the activity as proposed is exempt, under Chapter 62-330.051(14)(a), Florida Administrative Code, from the need to obtain a regulatory permit under Part IV of Chapter 373 of the Florida Statutes.
This exemption verification is based on the information you provided the Department and the statutes and rules in effect when the information was submitted. This verification may not be valid if site conditions materially change, the project design is modified, or the statutes or rules governing the exempt activity are amended. In the event you need to re-verify the exempt status for the activity, a new request and verification fee will be required. Any substantial modifications to the project design should be submitted to the Department for review, as changes may result in a permit being required.
2. Proprietary Review- GRANTED
The Department acts as staff to the Board of Trustees of the Internal Improvement Trust Fund
(Board of Trustees) and issues certain authorizations for the use of sovereign submerged lands.
The Department has the authority to review activities on sovereign submerged lands under
Chapters 253 and 258 of the Florida Statutes, and Chapters 18-20 and 18-21 of the Florida
Administrative Code.
The activity appears to be located on sovereign submerged lands owned by the Board of
Trustees. The activity is not exempt from the need to obtain the applicable proprietary authorization. As staff to the Board of Trustees, the Department has reviewed the activity described above, and has determined that the activity qualifies for a letter of consent under
Section 253.77, Florida Statutes, to construct and use the activity on the specified sovereign submerged lands, as long as the work performed is located within the boundaries as described herein and is consistent with the terms and conditions herein.
During the term of this Letter of Consent you shall maintain satisfactory evidence of sufficient upland interest as required by paragraph 18-21.004(3)(b), Florida Administrative Code. If such interest is terminated or the Board of Trustees determines that such interest did not exist on the date of issuance of this Letter of Consent, this Letter of Consent may be terminated by the Board of Trustees at its sole option. If the Board of Trustees terminates this Letter of Consent, you agree not to assert a claim or defense against the Board of Trustees arising out of this Letter of
Consent.
Special Consent Conditions
1. The applicant agrees to indemnify, defend and hold harmless the Board of Trustees and the State of Florida from all claims, actions, lawsuits and demands in any form arising out of the authorization to use sovereignty submerged lands or the applicant’s use and construction of structures on sovereignty submerged lands. This duty to indemnify and hold harmless will include any and all liabilities that are associated with the structure or activity including special assessments or taxes that are now or in the future assessed against the structure or activity during the period of the authorization.
2. Failure by the Board of Trustees to enforce any violation of a provision of the authorization or waiver by the Board of Trustees of any provision of the authorization will not invalidate the provision not enforced or waived, nor will the failure to enforce or a waiver prevent the Board of Trustees from enforcing the unenforced or waived provision in the event of a violation of that provision.
3. Applicant binds itself and its successors and assigns to abide by the provisions and conditions set forth in the authorization. If the applicant or its successors or assigns fails or refuses to comply with the provisions and conditions of the authorization, the authorization may be terminated by the Board of Trustees after written notice to the applicant or its successors or assigns. Upon receipt of such notice, the applicant or its successors or assigns will have thirty (30) days in which to correct the violations. Failure to correct the violations within this period will result in the automatic revocation of this authorization.
4. All costs incurred by the Board of Trustees in enforcing the terms and conditions of the authorization will be paid by the applicant. Any notice required by law will be made by certified mail at the address shown on page one of the authorization. The applicant will notify the Board of Trustees in writing of any change of address at least ten days before the change becomes effective.
5. This authorization does not allow any activity prohibited in a conservation easement or restrictive covenant that prohibits the activity.
General Conditions for Authorizations for Activities
All authorizations granted by rule or in writing under Rule 18-21.005, F.A.C., except those for geophysical testing, shall be subject to the general conditions as set forth in paragraphs (a) through
(i) below. The general conditions shall be part of all authorizations under this chapter, shall be binding upon the grantee, and shall be enforceable under Chapter 253 or 258, Part II, F.S.
(a) Authorizations are valid only for the specified activity or use. Any unauthorized deviation from the specified activity or use and the conditions for undertaking that activity or use shall constitute a violation. Violation of the authorization shall result in suspension or revocation of the grantee’s use of the sovereignty submerged land unless cured to the satisfaction of the Board.
(b) Authorizations convey no title to sovereignty submerged land or water column, nor do they constitute recognition or acknowledgment of any other person’s title to such land or water.
(c) Authorizations may be modified, suspended or revoked in accordance with their terms or the remedies provided in Sections 253.04 and 258.46, F.S., or Chapter 18-14, F.A.C.
(d) Structures or activities shall be constructed and used to avoid or minimize adverse impacts to sovereignty submerged lands and resources.
(e) Construction, use, or operation of the structure or activity shall not adversely affect any species which is endangered, threatened or of special concern, as listed in Rules 68A-27.003, 68A-27.004, and 68A-27.005, F.A.C.
(f) Structures or activities shall not unreasonably interfere with riparian rights. When a court of competent jurisdiction determines that riparian rights have been unlawfully affected, the structure or activity shall be modified in accordance with the court’s decision.
(g) Structures or activities shall not create a navigational hazard.
(h) Structures shall be maintained in a functional condition and shall be repaired or removed if they become dilapidated to such an extent that they are no longer functional. This shall not be construed to prohibit the repair or replacement subject to the provisions of Rule 18-21.005, F.A.C., within one year, of a structure damaged in a discrete event such as a storm, flood, accident, or fire.
(i) Structures or activities shall be constructed, operated, and maintained solely for water dependent purposes, or for non-water dependent activities authorized under Paragraph 18-
21.004(1)(f), F.A.C., or any other applicable law.
3. Federal Review - NOT APPROVED
Your proposed activity as outlined on your application and attached drawings does not qualify for Federal authorization pursuant to the State Programmatic General Permit and a SEPARATE permit or authorization shall be required from the Corps. You must apply separately to the
Corps using their APPLICATION FOR DEPARTMENT OF THE ARMY PERMIT, ENG
FORM 4345, or alternative as allowed by their regulations. More information on Corps permitting may be found online in the Jacksonville District Regulatory Division Source Book at:
https://www.saj.usace.army.mil/Missions/Regulatory/Source-Book.
Authority for review - an agreement with the USACOE entitled “Coordination Agreement
Between the U. S. Army Corps of Engineers (Jacksonville District) and the Florida Department of Environmental Protection (or Duly Authorized Designee), State Programmatic General
Permit”, Section 10 of the Rivers and Harbor Act of 1899, and Section 404 of the Clean Water
Act.
Additional Information
Please retain this letter. The activities may be inspected by authorized state personnel in the future to ensure compliance with appropriate statutes and administrative codes. If the activities are not in compliance, you may be subject to penalties under Chapter 373, F.S., and Chapter 18-
14, F.A.C.
NOTICE OF RIGHTS
This action is final and effective on the date filed with the Clerk of the Department unless a petition for an administrative hearing is timely filed under Sections 120.569 and 120.57, F.S., before the deadline for filing a petition. On the filing of a timely and sufficient petition, this action will not be https://www.saj.usace.army.mil/Missions/Regulatory/Source-Book final and effective until a subsequent order of the Department. Because the administrative hearing process is designed to formulate final agency action, the hearing process may result in a modification of the agency action or even denial of the application.
Petition for Administrative Hearing
A person whose substantial interests are affected by the Department’s action may petition for an administrative proceeding (hearing) under Sections 120.569 and 120.57, F.S. Pursuant to Rules 28-
106.201 and 28-106.301, F.A.C., a petition for an administrative hearing must contain the following information:
(a) The name and address of each agency affected and each agency’s file or identification number, if known;
(b) The name, address, any e-mail address, any facsimile number, and telephone number of the petitioner, if the petitioner is not represented by an attorney or a qualified representative; the name, address, and telephone number of the petitioner’s representative, if any, which shall be the address for service purposes during the course of the proceeding; and an explanation of how the petitioner’s substantial interests will be affected by the agency determination;
(c) A statement of when and how the petitioner received notice of the agency decision;
(d) A statement of all disputed issues of material fact. If there are none, the petition must so indicate;
(e) A concise statement of the ultimate facts alleged, including the specific facts that the petitioner contends warrant reversal or modification of the agency’s proposed action;
(f) A statement of the specific rules or statutes that the petitioner contends require reversal or modification of the agency’s proposed action, including an explanation of how the alleged facts relate to the specific rules or statutes; and
(g) A statement of the relief sought by the petitioner, stating precisely the action that the petitioner wishes the agency to take with respect to the agency’s proposed action.
The petition must be filed (received by the Clerk) in the Office of General Counsel of the
Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-
3000, or via electronic correspondence at Agency_Clerk@dep.state.fl.us. Also, a copy of the petition shall be mailed to the applicant at the address indicated above at the time of filing.
Time Period for Filing a Petition
In accordance with Rule 62-110.106(3), F.A.C., petitions for an administrative hearing by the applicant and persons entitled to written notice under Section 120.60(3), F.S., must be filed within 21 days of receipt of this written notice. Petitions filed by any persons other than the applicant, and other than those entitled to written notice under Section 120.60(3), F.S., must be filed within 21 days of publication of the notice or within 21 days of receipt of the written notice, whichever occurs first. You cannot justifiably rely on the finality of this decision unless notice of this decision and the right of substantially affected persons to challenge this decision has been duly published or otherwise provided to all persons substantially affected by the decision. While you are not required to publish notice of this action, you may elect to do so pursuant Rule 62-
110.106(10)(a).
mailto:Agency_Clerk@dep.state.fl.us
The failure to file a petition within the appropriate time period shall constitute a waiver of that person's right to request an administrative determination (hearing) under Sections 120.569 and
120.57, F.S., or to intervene in this proceeding and participate as a party to it. Any subsequent intervention (in a proceeding initiated by another party) will be only at the discretion of the presiding officer upon the filing of a motion in compliance with Rule 28-106.205, F.A.C. If you do not publish notice of this action, this waiver will not apply to persons who have not received written notice of this action.
Extension of Time
Under Rule 62-110.106(4), F.A.C., a person whose substantial interests are affected by the
Department’s action may also request an extension of time to file a petition for an administrative hearing. The Department may, for good cause shown, grant the request for an extension of time.
Requests for extension of time must be filed with the Office of General Counsel of the
Department at 3900 Commonwealth Boulevard, Mail Station 35, Tallahassee, Florida 32399-
3000, or via electronic correspondence at Agency_Clerk@dep.state.fl.us, before the deadline for filing a petition for an administrative hearing. A timely request for extension of time shall toll the running of the time period for filing a petition until the request is acted upon.
Mediation
Mediation is not available in this proceeding.
FLAWAC Review
The applicant, or any party within the meaning of Section 373.114(1)(a) or 373.4275, F.S., may also seek appellate review of this order before the Land and Water Adjudicatory Commission under Section 373.114(1) or 373.4275, F.S. Requests for review before the Land and Water
Adjudicatory Commission must be filed with the Secretary of the Commission and served on the
Department within 20 days from the date when this order is filed with the Clerk of the
Department.
Judicial Review
Once this decision becomes final, any party to this action has the right to seek judicial review pursuant to Section 120.68, F.S., by filing a Notice of Appeal pursuant to Florida Rules of
Appellate Procedure 9.110 and 9.190 with the Clerk of the Department in the Office of General
Counsel (Station #35, 3900 Commonwealth Boulevard, Tallahassee, Florida 32399-3000) and by filing a copy of the Notice of Appeal accompanied by the applicable filing fees with the appropriate district court of appeal. The notice must be filed within 30 days from the date this action is filed with the Clerk of the Department.
http://web2.westlaw.com/find/default.wl?ordoc=I0C7293C0912311DB8F8F8100D79B57CF&rp=%2ffind%2fdefault.wl&DB=1000006&DocName=FLSTS120%2E569&FindType=L&AP=&rs=WLW9.08&ifm=NotSet&fn=_top&sv=Split&mt=Florida&utid=4&vr=2.0&pbc=38B33E51 mailto:Agency_Clerk@dep.state.fl.us
EXECUTION AND CLERKING
Executed in Palm Beach County, Florida.
STATE OF FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION
Jacqueline Hurd
Environmental Manager
Southeast District
Enclosures:
Attachment A- Specific Exemption Rule
Project drawings, 7 pages
CERTIFICATE OF SERVICE
The undersigned duly designated deputy clerk hereby certifies that this document and all attachments were sent on the filing date below to the following listed persons:
FDEP – Jacqueline Hurd, Amber Maier
Austin Arnold, Austin.arnold@kci.com
FILING AND ACKNOWLEDGMENT
FILED, on this date, pursuant to Section 120.52, F. S., with the designated Department Clerk, receipt of which is hereby acknowledged.
Clerk Date 07/07/2026 mailto:Austin.arnold@kci.com
Attachment A
Chapter 62-330.051 Exempt Activities.
The activities meeting the limitations and restrictions below are exempt from permitting. However, if located in, on, or over state-owned submerged lands, they are subject to a separate authorization under Chapters 253 and 258, F.S., and Chapters 18-18, 18-20, and 18-21, F.A.C., as applicable.
(14) Utilities ‒
(a) Installation of overhead transmission lines in accordance with section 403.813(1)(a), F.S.
Rulemaking Authority 373.026(7), 373.043, 373.4131, 373.4145, 403.805(1) FS. Law Implemented 373.406, 373.4131, 373.4145, 373.415, 403.813(1) FS. History–New 10-1-13, Amended 6-1-18.
ROW
ROW
ROW
ROW
ROW
RO
W
ROW
ROW
C5-1297
EXISTING POLE
MILEPOST: 5.077
CROSS SECTION 2
C5-1296
EXISTING POLE
MILEPOST: 5.180
CROSS SECTION 1
INSTALL 590' OF 144 STRAND
ADSS FIBER OPTIC CABLE
US ROUTE 1
US ROUTE 1
VACA CUT BRIDGE
BUILDING
#11710
N
PLAN VIEW
GAS
WATER
STORM DRAIN
SANITARY SEWER
RECLAIMED WATER
ELECTRIC
TELEPHONE
RIGHT OF WAY
BURIED UTILITIES
G
W
D
S
R
E
T
SCOPE OF WORK
ABBREVIATIONS
AC
CI
DIP
EOP
EOS
FM
PVC
ASBESTOS CEMENT
CAST IRON
DUCTILE IRON PIPE
EDGE OF PAVEMENT
EDGE OF SIDEWALK
FORCE MAIN
POLYVINYL CHLORIDE
RCP
TX
UG
REINFORCED CONCRETE PIPE
TRANSFORMER
UNDERGROUND
CENTER LINE
ROW
POLE
TRANSFORMER
PEDESTAL
PULLBOX
TRANSFORMER IN PROPERTY
PEDESTAL IN PROPERTY
PULLBOX IN PROPERTY
UNDERGROUND CABLE
AERIAL CABLE
INSTALL EXISTING/REMOVE
LEGEND
P
P
P
F
F F
POLE
TRANSFORMER
PEDESTAL
PULLBOX
TRANSFORMER IN PROPERTY
PEDESTAL IN PROPERTY
PULLBOX IN PROPERTY
UNDERGROUND CABLE
AERIAL CABLE
P
F
GENERAL CONSTRUCTION NOTES:
· RIGHT OF WAYS WILL BE RESTORED TO AS
GOOD AS OR BETTER THAN ORIGINAL
CONDITION.
· TO AVOID CONFLICTS, CONTRACTOR WILL
COORDINATE DEPTH OF UNDERGROUND
FACILITIES WITH THE MUNICIPALITY
INSPECTOR PRIOR TO BORES BEING
INSTALLED.
· ALL PULL BOX LIDS SHALL BE TRAFFIC
RATED WHEN INSTALLED WITHIN THE
RIGHT OF WAY.
· CONTRACTOR SHALL MAINTAIN AN
UNINTERRUPTED ACCESS TO ALL
DRIVEWAYS, SIDEWALKS AND SIDE
STREETS ALWAYS, UNLESS OTHERWISE
APPROVED ON THE MOT PERMIT.
· ALL OTHER RIGHT OF WAY USERS AND
MUNICIPALITIES IN THE IMMEDIATE
VICINITY OF THE PROPOSED
CONSTRUCTION/INSTALLATION HAVE BEEN
NOTIFIED IN WRITING.
Circuit ID: XXX Primary Voltage: 12.47/7.2KV
VACA BRIDGE CROSSING
PROJECT SITE ADDRESS: 11710 OVERSEAS HIGHWAY
MARATHON, FL, 33050 - MONROE COUNTY
SCOPE OF WORK: INSTALL 590' OF OVERHEAD WIRE
W.O.O.: PETER AMENDOLA
PH: 305-852-2431 x240
SECTION: 05 TWP: 66 RANGE: 33
REV: N/A SCALE: N/ADATE: 10/16/2025
PRINT: 1 OF 7
INSTALL 590' OF OVERHEAD WIRE
MOT INDEX
MILE POSTS
102-602
START: 5.077
END: 5.180
C5-1297: 5.077
C5-1296: 5.180
117TH STREET: 5.005
02/27/2026
SAFETY NOTES:
TO PREVENT FIBER FROM FALLING INTO OR
CLOSELY ABOVE VACA CUT, THE FIBER WILL BE
DISPENSED FROM A TRUCK MOUNTED REEL
WITH A FRICTION BRAKE ASSEMBLY AND
ADDITIONALLY SECURED WITH A HANDLINE TO
ENSURE FULL CONTROL THROUGHOUT THE
INSTALLATION PROCESS.
THE LINES WILL BE INSTALLED UTILIZING
INDUSTRY STANDARD SAFE WORK PRACTICES
AND NATIONAL ELECTRIC SAFETY CODE
GUIDELINES. NO CONTACT WITH THE WATER IS
EXPECTED. NO CONTACT WITH THE CHANNEL
FLOOR WILL OCCUR.
EXISTING POLES
ARE LOCATED IN
UPLANDS
GPS COORDINATES:
C5-1296: 24.730814, -81.028699 C5-1297: 24.730464, -81.030434
US ROUTE 1
7T
H S
TR
EE
T
VICNITY MAP
GAS
WATER
STORM DRAIN
SANITARY SEWER
RECLAIMED WATER
ELECTRIC
TELEPHONE
RIGHT OF WAY
BURIED UTILITIES
G
W
D
S
R
E
T
SCOPE OF WORK
INSTALL 590' OF OVERHEAD WIRE
ABBREVIATIONS
AC
CI
DIP
EOP
EOS
FM
PVC
ASBESTOS CEMENT
CAST IRON
DUCTILE IRON PIPE
EDGE OF PAVEMENT
EDGE OF SIDEWALK
FORCE MAIN
POLYVINYL CHLORIDE
RCP
TX
UG
REINFORCED CONCRETE PIPE
TRANSFORMER
UNDERGROUND
CENTER LINE
ROW
Circuit ID: XXX Primary Voltage: 12.47/7.2KV
VACA BRIDGE CROSSING
PROJECT SITE ADDRESS: 11710 OVERSEAS HIGHWAY
MARATHON, FL, 33050 - MONROE COUNTY
SCOPE OF WORK: INSTALL 590' OF OVERHEAD WIRE
W.O.O.: PETER AMENDOLA
PH: 305-852-2431 x240
SECTION: 05 TWP: 66 RANGE: 33
REV: N/A SCALE: N/ADATE: 10/16/2025
PRINT: 2 OF 7
POLE
TRANSFORMER
PEDESTAL
PULLBOX
TRANSFORMER IN PROPERTY
PEDESTAL IN PROPERTY
PULLBOX IN PROPERTY
UNDERGROUND CABLE
AERIAL CABLE
INSTALL EXISTING/REMOVE
LEGEND
POLE
TRANSFORMER
PEDESTAL
PULLBOX
TRANSFORMER IN PROPERTY
PEDESTAL IN PROPERTY
PULLBOX IN PROPERTY
UNDERGROUND CABLE
AERIAL CABLE
P
F
P
F
P
F
P
F
N
MOT INDEX
MILE POSTS
102-602
START: 5.077
END: 5.180
C5-1297: 5.077
C5-1296: 5.180
117TH STREET: 5.005
GENERAL CONSTRUCTION NOTES:
· RIGHT OF WAYS WILL BE RESTORED TO AS
GOOD AS OR BETTER THAN ORIGINAL
CONDITION.
· TO AVOID CONFLICTS, CONTRACTOR WILL
COORDINATE DEPTH OF UNDERGROUND
FACILITIES WITH THE MUNICIPALITY
INSPECTOR PRIOR TO BORES BEING
INSTALLED.
· ALL PULL BOX LIDS SHALL BE TRAFFIC
RATED WHEN INSTALLED WITHIN THE
RIGHT OF WAY.
· CONTRACTOR SHALL MAINTAIN AN
UNINTERRUPTED ACCESS TO ALL
DRIVEWAYS, SIDEWALKS AND SIDE
STREETS ALWAYS, UNLESS OTHERWISE
APPROVED ON THE MOT PERMIT.
· ALL OTHER RIGHT OF WAY USERS AND
MUNICIPALITIES IN THE IMMEDIATE
VICINITY OF THE PROPOSED
CONSTRUCTION/INSTALLATION HAVE BEEN
NOTIFIED IN WRITING.
02/27/2026
SAFETY NOTES:
TO PREVENT FIBER FROM FALLING INTO OR
CLOSELY ABOVE VACA CUT, THE FIBER WILL BE
DISPENSED FROM A TRUCK MOUNTED REEL
WITH A FRICTION BRAKE ASSEMBLY AND
ADDITIONALLY SECURED WITH A HANDLINE TO
ENSURE FULL CONTROL THROUGHOUT THE
INSTALLATION PROCESS.
THE LINES WILL BE INSTALLED UTILIZING
INDUSTRY STANDARD SAFE WORK PRACTICES
AND NATIONAL ELECTRIC SAFETY CODE
GUIDELINES. NO CONTACT WITH THE WATER IS
EXPECTED. NO CONTACT WITH THE CHANNEL
FLOOR WILL OCCUR.
CROSS SECTION #1
LOOKING SOUTHWEST
0" 12" 24" 36" 48" 60" 72" 84" 96"
108"
0" 12" 24" 36" 48" 60" 72" 84" 96" 108"
R/W
Hor. Scale : 1" = 20' Vert. Scale: 1" = 5'
US ROUTE 1
EOP
C/L
R/WEOP
NOTE:
· CONTRACTOR SHALL CALL SUNSHINE STATE
"ONE CALL" FOR LOCATES OF THE EXISTING
UTILITIES PRIOR TO CONSTRUCTION.
· ALL WORK SHALL COMPLY WITH ALL CITY,
STATE, AND FEDERAL REGULATIONS &
GUIDELINES.
· THE UAO SHALL COMPLY WITH THE UAM 2017.
GENERAL CONSTRUCTION NOTES:
· RIGHT OF WAYS WILL BE RESTORED TO AS
GOOD AS OR BETTER THAN ORIGINAL
CONDITION.
· TO AVOID CONFLICTS, CONTRACTOR WILL
COORDINATE DEPTH OF UNDERGROUND
FACILITIES WITH THE MUNICIPALITY
INSPECTOR PRIOR TO BORES BEING
INSTALLED.
· ALL PULL BOX LIDS SHALL BE TRAFFIC
RATED WHEN INSTALLED WITHIN THE
RIGHT OF WAY.
· CONTRACTOR SHALL MAINTAIN AN
UNINTERRUPTED ACCESS TO ALL
DRIVEWAYS, SIDEWALKS AND SIDE
STREETS ALWAYS, UNLESS OTHERWISE
APPROVED ON THE MOT PERMIT.
· ALL OTHER RIGHT OF WAY USERS AND
MUNICIPALITIES IN THE IMMEDIATE
VICINITY OF THE PROPOSED
CONSTRUCTION/INSTALLATION HAVE BEEN
NOTIFIED IN WRITING.
Circuit ID: XXX Primary Voltage: 12.47/7.2KV
VACA BRIDGE CROSSING
PROJECT SITE ADDRESS: 11710 OVERSEAS HIGHWAY
MARATHON, FL, 33050 - MONROE COUNTY
SCOPE OF WORK: INSTALL 590' OF OVERHEAD WIRE
W.O.O.: PETER AMENDOLA
PH: 305-852-2431 x240
SECTION: 05 TWP: 66 RANGE: 33
REV: N/A SCALE: N/ADATE: 10/16/2025
PRINT: 3 OF 7
37'
C5-1296
EXISTING POLE
02/27/2026
SAFETY NOTES:
TO PREVENT FIBER FROM FALLING INTO OR
CLOSELY ABOVE VACA CUT, THE FIBER WILL BE
DISPENSED FROM A TRUCK MOUNTED REEL
WITH A FRICTION BRAKE ASSEMBLY AND
ADDITIONALLY SECURED WITH A HANDLINE TO
ENSURE FULL CONTROL THROUGHOUT THE
INSTALLATION PROCESS.
THE LINES WILL BE INSTALLED UTILIZING
INDUSTRY STANDARD SAFE WORK PRACTICES
AND NATIONAL ELECTRIC SAFETY CODE
GUIDELINES. NO CONTACT WITH THE WATER IS
EXPECTED. NO CONTACT WITH THE CHANNEL
FLOOR WILL OCCUR.
EXISTING POLES
ARE LOCATED IN
UPLANDS
CROSS SECTION #2
LOOKING SOUTHWEST
0" 12" 24" 36" 48" 60" 72" 84" 96"
108"
0" 12" 24" 36" 48" 60" 72" 84" 96" 108"
R/W
Hor. Scale : 1" = 20' Vert. Scale: 1" = 5'
US ROUTE 1
EOP
C/L
R/WEOP
NOTE:
· CONTRACTOR SHALL CALL SUNSHINE STATE
"ONE CALL" FOR LOCATES OF THE EXISTING
UTILITIES PRIOR TO CONSTRUCTION.
· ALL WORK SHALL COMPLY WITH ALL CITY,
STATE, AND FEDERAL REGULATIONS &
GUIDELINES.
· THE UAO SHALL COMPLY WITH THE UAM 2017.
GENERAL CONSTRUCTION NOTES:
· RIGHT OF WAYS WILL BE RESTORED TO AS
GOOD AS OR BETTER THAN ORIGINAL
CONDITION.
· TO AVOID CONFLICTS, CONTRACTOR WILL
COORDINATE DEPTH OF UNDERGROUND
FACILITIES WITH THE MUNICIPALITY
INSPECTOR PRIOR TO BORES BEING
INSTALLED.
· ALL PULL BOX LIDS SHALL BE TRAFFIC
RATED WHEN INSTALLED WITHIN THE
RIGHT OF WAY.
· CONTRACTOR SHALL MAINTAIN AN
UNINTERRUPTED ACCESS TO ALL
DRIVEWAYS, SIDEWALKS AND SIDE
STREETS ALWAYS, UNLESS OTHERWISE
APPROVED ON THE MOT PERMIT.
· ALL OTHER RIGHT OF WAY USERS AND
MUNICIPALITIES IN THE IMMEDIATE
VICINITY OF THE PROPOSED
CONSTRUCTION/INSTALLATION HAVE BEEN
NOTIFIED IN WRITING.
Circuit ID: XXX Primary Voltage: 12.47/7.2KV
VACA BRIDGE CROSSING
PROJECT SITE ADDRESS: 11710 OVERSEAS HIGHWAY
MARATHON, FL, 33050 - MONROE COUNTY
SCOPE OF WORK: INSTALL 590' OF OVERHEAD WIRE
W.O.O.: PETER AMENDOLA
PH: 305-852-2431 x240
SECTION: 05 TWP: 66 RANGE: 33
REV: N/A SCALE: N/ADATE: 10/16/2025
PRINT: 4 OF 7
35'
C5-1297
EXISTING POLE
02/27/2026
SAFETY NOTES:
TO PREVENT FIBER FROM FALLING INTO OR
CLOSELY ABOVE VACA CUT, THE FIBER WILL BE
DISPENSED FROM A TRUCK MOUNTED REEL
WITH A FRICTION BRAKE ASSEMBLY AND
ADDITIONALLY SECURED WITH A HANDLINE TO
ENSURE FULL CONTROL THROUGHOUT THE
INSTALLATION PROCESS.
THE LINES WILL BE INSTALLED UTILIZING
INDUSTRY STANDARD SAFE WORK PRACTICES
AND NATIONAL ELECTRIC SAFETY CODE
GUIDELINES. NO CONTACT WITH THE WATER IS
EXPECTED. NO CONTACT WITH THE CHANNEL
FLOOR WILL OCCUR.
EXISTING POLES
PROFILE VIEW #1
156" 144" 132" 120" 108" 96" 84" 72" 60" 48" 36" 24" 12"
0"
156" 144" 132" 120" 108" 96" 84" 72" 60" 48" 36" 24" 12" 0"
Hor. Scale : 1" = 40' Vert. Scale: 1" = 5'
NOTE:
· CONTRACTOR SHALL CALL SUNSHINE STATE
"ONE CALL" FOR LOCATES OF THE EXISTING
UTILITIES PRIOR TO CONSTRUCTION.
· ALL WORK SHALL COMPLY WITH ALL CITY,
STATE, AND FEDERAL REGULATIONS &
GUIDELINES.
· THE UAO SHALL COMPLY WITH THE UAM 2017.
GENERAL CONSTRUCTION NOTES:
· RIGHT OF WAYS WILL BE RESTORED TO AS
GOOD AS OR BETTER THAN ORIGINAL
CONDITION.
· TO AVOID CONFLICTS, CONTRACTOR WILL
COORDINATE DEPTH OF UNDERGROUND
FACILITIES WITH THE MUNICIPALITY
INSPECTOR PRIOR TO BORES BEING
INSTALLED.
· ALL PULL BOX LIDS SHALL BE TRAFFIC
RATED WHEN INSTALLED WITHIN THE
RIGHT OF WAY.
· CONTRACTOR SHALL MAINTAIN AN
UNINTERRUPTED ACCESS TO ALL
DRIVEWAYS, SIDEWALKS AND SIDE
STREETS ALWAYS, UNLESS OTHERWISE
APPROVED ON THE MOT PERMIT.
· ALL OTHER RIGHT OF WAY USERS AND
MUNICIPALITIES IN THE IMMEDIATE
VICINITY OF THE PROPOSED
CONSTRUCTION/INSTALLATION HAVE BEEN
NOTIFIED IN WRITING.
Circuit ID: XXX Primary Voltage: 12.47/7.2KV
VACA BRIDGE CROSSING
PROJECT SITE ADDRESS: 11710 OVERSEAS HIGHWAY
MARATHON, FL, 33050 - MONROE COUNTY
SCOPE OF WORK: INSTALL 590' OF OVERHEAD WIRE
W.O.O.: PETER AMENDOLA
PH: 305-852-2431 x240
SECTION: 05 TWP: 66 RANGE: 33
REV: N/A SCALE: N/ADATE: 10/16/2025
PRINT: 5 OF 7
C5-1296
EXISTING POLE
C5-1297
EXISTING POLE
INSTALL 590' OF 144 STRAND
ADSS FIBER OPTIC CABLE
VACA CUT BRIDGE
02/27/2026
EXISTING POLES ARE LOCATED IN UPLANDS
LOOKING WEST
NOTE:
· CONTRACTOR SHALL CALL SUNSHINE STATE
"ONE CALL" FOR LOCATES OF THE EXISTING
UTILITIES PRIOR TO CONSTRUCTION.
· ALL WORK SHALL COMPLY WITH ALL CITY,
STATE, AND FEDERAL REGULATIONS &
GUIDELINES.
· THE UAO SHALL COMPLY WITH THE UAM 2017.
GENERAL CONSTRUCTION NOTES:
· RIGHT OF WAYS WILL BE RESTORED TO AS
GOOD AS OR BETTER THAN ORIGINAL
CONDITION.
· TO AVOID CONFLICTS, CONTRACTOR WILL
COORDINATE DEPTH OF UNDERGROUND
FACILITIES WITH THE MUNICIPALITY
INSPECTOR PRIOR TO BORES BEING
INSTALLED.
· ALL PULL BOX LIDS SHALL BE TRAFFIC
RATED WHEN INSTALLED WITHIN THE
RIGHT OF WAY.
· CONTRACTOR SHALL MAINTAIN AN
UNINTERRUPTED ACCESS TO ALL
DRIVEWAYS, SIDEWALKS AND SIDE
STREETS ALWAYS, UNLESS OTHERWISE
APPROVED ON THE MOT PERMIT.
· ALL OTHER RIGHT OF WAY USERS AND
MUNICIPALITIES IN THE IMMEDIATE
VICINITY OF THE PROPOSED
CONSTRUCTION/INSTALLATION HAVE BEEN
NOTIFIED IN WRITING.
Circuit ID: XXX Primary Voltage: 12.47/7.2KV
VACA BRIDGE CROSSING
PROJECT SITE ADDRESS: 11710 OVERSEAS HIGHWAY
MARATHON, FL, 33050 - MONROE COUNTY
SCOPE OF WORK: INSTALL 590' OF OVERHEAD WIRE
W.O.O.: PETER AMENDOLA
PH: 305-852-2431 x240
SECTION: 05 TWP: 66 RANGE: 33
REV: N/A SCALE: N/ADATE: 10/16/2025
PRINT: 6 OF 7
02/27/2026
EXISTING POLES
LOOKING WEST
NOTE:
· CONTRACTOR SHALL CALL SUNSHINE STATE
"ONE CALL" FOR LOCATES OF THE EXISTING
UTILITIES PRIOR TO CONSTRUCTION.
· ALL WORK SHALL COMPLY WITH ALL CITY,
STATE, AND FEDERAL REGULATIONS &
GUIDELINES.
· THE UAO SHALL COMPLY WITH THE UAM 2017.
GENERAL CONSTRUCTION NOTES:
· RIGHT OF WAYS WILL BE RESTORED TO AS
GOOD AS OR BETTER THAN ORIGINAL
CONDITION.
· TO AVOID CONFLICTS, CONTRACTOR WILL
COORDINATE DEPTH OF UNDERGROUND
FACILITIES WITH THE MUNICIPALITY
INSPECTOR PRIOR TO BORES BEING
INSTALLED.
· ALL PULL BOX LIDS SHALL BE TRAFFIC
RATED WHEN INSTALLED WITHIN THE
RIGHT OF WAY.
· CONTRACTOR SHALL MAINTAIN AN
UNINTERRUPTED ACCESS TO ALL
DRIVEWAYS, SIDEWALKS AND SIDE
STREETS ALWAYS, UNLESS OTHERWISE
APPROVED ON THE MOT PERMIT.
· ALL OTHER RIGHT OF WAY USERS AND
MUNICIPALITIES IN THE IMMEDIATE
VICINITY OF THE PROPOSED
CONSTRUCTION/INSTALLATION HAVE BEEN
NOTIFIED IN WRITING.
Circuit ID: XXX Primary Voltage: 12.47/7.2KV
VACA BRIDGE CROSSING
PROJECT SITE ADDRESS: 11710 OVERSEAS HIGHWAY
MARATHON, FL, 33050 - MONROE COUNTY
SCOPE OF WORK: INSTALL 590' OF OVERHEAD WIRE
W.O.O.: PETER AMENDOLA
PH: 305-852-2431 x240
SECTION: 05 TWP: 66 RANGE: 33
REV: N/A SCALE: N/ADATE: 10/16/2025
PRINT: 7 OF 7
02/27/2026
EXISTING POLES
| UPDATED PROJECT DRAWINGS W GPS.pdf |
| Sheets and Views |
| BRIDGE CROSSING PERMIT-PLAN VIEW |
| BRIDGE CROSSING PERMIT-VICINITY MAP |
| BRIDGE CROSSING PERMIT-CROSS SECTION |
| BRIDGE CROSSING PERMIT-CROSS SECTION (2) |
| BRIDGE CROSSING PERMIT-PROFILE VIEW |
| BRIDGE CROSSING PERMIT-PHOTO SHEET |
| BRIDGE CROSSING PERMIT-PHOTO SHEET (2) |
File details come from the government source that posted it. Updated .