Electric-Telecom Drawings.pdf

PDF 3 MB Posted

Attached to
Z1DA--Project# 614-19-102 - Reno Bldg. 7 Spinal Cord Injury Rehab Area
Solicitation number
36C24920B0003
Issued by

About this file

This solicitation is for a renovation project at Building 7 at the Memphis VA Medical Center. The project scope includes renovations to the Spinal Cord Injury Rehab Area. An IFB will be issued under solicitation number 36C24919B0001_1 to fulfill presolicitation requirements. The work includes mechanical, electrical, and plumbing renovations. The required completion date is not specified. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 9 is the contracting agency. Pricing terms and subcontracting goals are not discussed.

View the file

Other files

File Type Posted
36C24920B0003 0007.docx DOCX document
36C24920B0003 0006.docx DOCX document
36C24920B0003 0005.docx DOCX document
36C24920B0003 0004.docx DOCX document
Amendent_SPECS.pdf PDF
Amend Rpt 0001.pdf PDF
Amendment_DRAWINGS.pdf PDF
36C24920B0003 0003.docx DOCX document
RFI Form - Renovate Bldg. 7 SCI Rehab Area.docx DOCX document
Contractor EMR Certification Form 2020.docx DOCX document
36C24920B0003 0002.docx DOCX document
36C24920B0003 0001.docx DOCX document
Drawings 614-19-102.pdf PDF
36C24920B0003_1.docx DOCX document
Addendum G-101.pdf PDF
Architectural Drawings 2.pdf PDF
Wage Determination - Shelby County.pdf PDF
Specifications.pdf PDF
Architectural Drawings 1.pdf PDF
Mechanical Drawings.pdf PDF
Fire-Plumbing Drawings.pdf PDF
General Drawings.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET NAMING CONVENTION

E-001A

2 DIGIT SEQUENTIAL # (01-99)

(FIRST DIGIT INDICATES PLAN

TYPE. SECOND DIGIT INDICATES

FLOOR)

1 DIGIT SHEET TYPE DESIGNATOR

0 - GENERAL

1 - PLANS

2 - ELEVATIONS

3 - SECTIONS

4 - ENLARGED PLANS

5 - DETAILS

6 - SCHEDULES AND DIAGRAMS

7 - VARIES

8 - VARIES

9 - 3D VIEWS (ISO, PERSPECTIVES)

2 DIGIT DESCIPLINE

DESIGNATOR

(IF ONLY ONE LETTER IS

USED, THE SECOND

LETTER IS REPLACED

WITH A DASH "-" AS A

PLACEHOLDER)**

1 DIGIT AREA

DESIGNATOR

(AREA DESIGNATOR

ONLY USED WHEN

PLANS ARE SUBDIVIDED

INTO AREAS.)

ELECTRICAL GENERAL NOTES:

1. THE WORK SHALL CONFORM WITH ALL REQUIREMENTS OF:

A. NFPA 70-2017 (NATIONAL ELECTRICAL CODE)

B. ANSI C2-2017 (NATIONAL ELECTRICAL SAFETY CODE)

C. APPLICABLE LOCAL CODES AND FEDERAL AND STATE LAWS.

D. UFC 4-510-01- NOVEMBER 2017 (MILITARY MEDICAL FACILITIES)

E. VA ELECTRICAL DESIGN MANUAL-DECEMBER 2015

2. MINIMUM RACEWAY SIZE SHALL BE 3/4". INCREASE RACEWAY SIZE AS REQUIRED TO LIMIT RACEWAY FILL RATIO TO LESS THAN 40%

FULL.

3. CONTRACTOR SHALL CAREFULLY COORDINATE WORK WITH OTHER TRADES THROUGH THE GENERAL CONTRACTOR AND SHALL BE RESPONSIBLE FOR SECURING SPACE REQUIREMENTS FOR ELECTRICAL EQUIPMENT CLEARANCE FOR RECESSED LIGHTING

FIXTURES AND CORRECT ROUGH-IN LOCATIONS OF ELECTRICAL CONNECTIONS.

4. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING CATALOG NUMBERS ON THESE DRAWINGS TO MATCH WITH MATERIAL

DESCRIPTIONS INDICATED.

5. VERIFY EXACT HEIGHT OF EACH COUNTERTOP AND BACKSPLASH ON ARCHITECTURAL DETAILS AND/OR CASE WORK SHOP DRAWINGS AND ADJUST SPECIFIED MOUNTING HEIGHT OF WALL OUTLETS TO LOCATE BOTTOM OF OUTLET BOX 4" ABOVE TOP OF BACKSPLASH. IF NO BACKSPLASH IS USED, LOCATE BOTTOM OF OUTLET BOX 6" ABOVE COUNTERTOP.

6. VERIFY DOOR SWINGS WITH ARCHITECTURAL DRAWINGS BEFORE ROUGHING IN WALL SWITCHES. SWITCHES IN THE SAME LOCATION SHALL BE GANGED TOGETHER IN ONE COMMON BACKBOX AND SHALL HAVE ONE COMMON FACE PLATE.

7. ALL FEEDERS AND BRANCH CIRCUITS SHALL INCLUDE A GREEN INSULATED GROUND CONDUCTOR, SIZE PER NATIONAL ELECTRICAL CODE, OR AS SHOWN, CONNECTED TO EACH DEVICE AND OUTLET BOX ON THE CIRCUIT AND TO THE PANELBOARD GROUND BUS. PROVIDE A DEDICATED NEUTRAL CONDUCTOR FOR EACH BRANCH CIRCUIT. MULTIPLE BRANCH CIRCUITS IN ONE

RACEWAY REQUIRE ONLY ONE GROUND CONDUCTOR.

8. VERIFY LUMINAIRE, CEILING MOUNTED OCCUPANCY SENSOR LOCATIONS WITH ARCHITECTURAL REFLECTED CEILING PLANS FOR EXACT LOCATIONS AND DIMENSIONS PRIOR TO INSTALLATION. VERIFY EXACT LOCATIONS OF MOTORS AND EQUIPMENT BEFORE

ROUGHING-IN.

9. EXISTING ELECTRICAL WORK (NOT SHOWN) SHALL REMAIN, UNLESS INDICATED OTHERWISE. SHOULD ANY EXISTING ELECTRICAL POWER, LIGHTING OR AUXILIARY CIRCUIT, FEEDER OR EQUIPMENT BE SEVERED, DISCONNECTED OR DELETED IN THE PROCESS OF CONSTRUCTION OR REMODELING WHICH IS DONE AS A RESULT OF CONTRACT PLANS AND SPECIFICATIONS, AND UNLESS SPECIFICALLY DESIGNATED BY THE DRAWINGS TO BE DELETED, THEN SAID CIRCUIT OR FEEDER SHALL BE RESTORED TO WORKING CONDITION. THE RESTORATION SHALL INCLUDE RE-ROUTING, RELOCATION, RECONNECTION OR REPLACEMENT AS MAY BE REQUIRED BY THE NEW WORK. ANY SUCH WORK REQUIRED SHALL BE INCLUDED IN THE CONTRACT AND NO EXTRA

COMPENSATION WILL BE GRANTED.

10. NEW WORK SHALL BE MADE TO TIE INTO THE EXISTING IN A UNIFORM MANNER, SIMILAR ITEMS OF NEW WORK SHALL BE CHECKED AGAINST EXISTING WORK FOR TYPE MOUNTING, MOUNTING HEIGHTS, ETC. ITEMS SHOWN IN NEW WORK AT VARIANCE FROM THE

EXISTING SHALL BE REFERRED TO THE ARCHITECT FOR DECISION BEFORE ROUGH-IN.

11. REFER TO ONE-LINE DIAGRAMS, SCHEDULES AND RISER DIAGRAMS FOR CONDUCTOR AND CONDUIT SIZES NOT SHOWN ON PLANS.

12. PROVIDE IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE TO STORE, FURNISH, INSTALL, MOUNT, CONNECT, CONTROL AND POWER EQUIPMENT INDICATED, AS WELL AS ALL APPURTENANCES REQUIRED TO MAKE ELECTRICAL SYSTEMS OPERATE AS INDICATED WITHIN THESE DRAWINGS AND

SPECIFICATIONS AND TO FULFILL THE SCOPE OF WORK.

13. DEMOLISH IS AN INCLUSIVE TERM USED TO DESCRIBE ASPECTS OF THE WORK TO BE ACCOMPLISHED, AND IS HEREBY DEFINED TO REQUIRE CONTRACTOR TO DISCONNECT EQUIPMENT FROM ALL CONNECTIONS, REMOVE FROM THE OWNER'S SITE, AND DISPOSE OF IN ACCORDANCE WITH FEDERAL, STATE AND LOCAL LAWS AND ORDINANCES. COST OF DISPOSAL IS ENTIRELY THE

CONTRACTOR'S RESPONSIBILITY.

14. ALL CONDUCTORS ARE COPPER UNLESS SPECIFICALLY NOTED AS ALUMINUM.

15. CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS, DIMENSIONS AND ELEVATIONS BEFORE PROCUREMENT OF ANY

MATERIALS AND DEVELOPMENT OF ANY SHOP DRAWINGS OR SUBMITTALS.

16. PROVIDE LABELS ON ALL RECEPTACLES, WALL MOUNTED LIGHT SWITCHES/OCCUPANCY SENSORS AND JUNCTION BOXES INDICATING THE SOURCE PANEL & CIRCUIT(S). TEXT SHALL BE BLACK, 1/8” IN HEIGHT PRINTED ON A CLEAR LABEL. HANDWRITTEN LABELS ARE NOT PERMITTED EXCEPT FOR JUNCTION BOXES LOCATED ABOVE FINISHED CEILING WHICH CAN BE HANDWRITTEN

WITH AN INDELIBLE MARKER.

• ALL EQUIPMENT PADS FOR INTERIOR ELECTRICAL EQUIPMENT SHALL EXTEND 2” BEYOND THE FOOTPRINT OF THE EQUIPMENT.

ELECTRICAL ABBREVIATIONS

A OR AMP

ACC

AC

AC

AF

AFF

AFG

AHU

AIC

AL

AM

ASYM

AT

ATS

AUTO

AWG

B

BC

BCW

BFF

BFG

BLDG

C

CAT

CB

CCT

CCTV

CFCI

CH

CHWCP

CHWP

CHWSP

CKT

CMH

CP

CPT

CRAC

CRI

CT

CT

CU

CWP

D

DC

DF

DH or DUH

DHWCP

DISC

DOAS

DPST

DPDT

DSCU

DSHP

DSS

DWBP

DX

EC

EF

ELEC

EMH

EMT

E or EMER

EPA

EQUIP

ERV

ERU

EXIST or EX

EUH

EXP

EWC

EWH

F

FACP

FCU

FLEX

FWE

G OR GND

GFGI

GFI

GRS

GUH

GWH

H or HT

HAC

HOA

HP

HP

HT

HVU

HWCP

HWP

AMPERE(S)

AIR COOLED CHILLER

ALTERNATING CURRENT

AIR COMPRESSOR / AIR CURTAIN

AMP FRAME

ABOVE FINISHED FLOOR

ABOVE FINISHED GRADE

AIR HANDLING UNIT

AMPERE INTERRUPTING CAPACITY

ALUMINUM

AMMETER

ASYMMETRICAL

AMP TRIP

AUTOMATIC TRANSFER SWITCH

AUTOMATIC

AMERICAN WIRE GAUGE

BOILER

BRANCH CONTROLLER

BARE COPPER WIRE

BELOW FINISHED FLOOR

BELOW FINISHED GRADE

BUILDING

CONDUIT

CATEGORY

CIRCUIT BREAKER

CORRELATED COLOR TEMPERATURE

CLOSED CIRCUIT TELEVISION

CONTRACTOR FURNISHED CONTRACTOR

INSTALLED

CHILLER

CHILLED WATER CIRCULATING PUMP IN A

PRIMARY-SECONDARY SYSTEM

CHILLED WATER PUMP

CHILLED WATER SUPPLY PUMP IN A PRIMARY-

SECONDARY SYSTEM

CIRCUIT

COMMUNICATIONS MANHOLE

CONDENSATE PUMP

CONTROL POWER TRANSFORMER

COMPUTER ROOM AC UNIT

COLOR RENDERING INDEX

CURRENT TRANSFORMER

COOLING TOWER

COPPER OR CONDENSING UNIT

CONDENSER WATER PUMP

DEPTH

DIRECT CURRENT

DESTRATIFICATION FAN

DUCT HEATERS

DOMESTIC HOT WATER CIRCULATING PUMP

DISCONNECT SWITCH

DEDICATED OUTSIDE AIR SYSTEM (UNIT)

DOUBLE POLE SINGLE THROW

DOUBLE POLE DOUBLE THROW

DUCTLESS SPLIT CONDENSING UNIT (POWERS

THE DSS INDOOR UNIT)

DUCTLESS SPLIT HEAT PUMP (POWERS THE

DSS INDOOR UNIT)

DUCTLESS SPLIT SYSTEM (INDOOR UNIT)

DOMESTIC WATER BOOSTER PUMP

DIRECT EXPANSION (DX) COOLING COIL

EMPTY CONDUIT

EXHAUST FAN

ELECTRICAL

ELECTRICAL MANHOLE

ELECTRICAL METALLIC TUBING

EMERGENCY

EFFECTIVE PROJECTED AREA

EQUIPMENT

ENERGY RECOVERY VENTILATOR

ENERGY RECOVERY UNIT

EXISTING

ELECTRIC UNIT HEATER

EXPLOSION PROOF

ELECTRIC WATER COOLER

ELECTRIC WATER HEATER

FUSE

FIRE ALARM CONTROL PANEL

FAN COIL UNIT

FLEXIBLE

FURNISHED WITH EQUIPMENT

GROUND

GOVERNMENT FURNISHED GOVERNMENT

INSTALLED

GROUND FAULT INTERRUPTER

GALVANIZED RIGID STEEL CONDUIT

GAS UNIT HEATER

GAS WATER HEATER

HEIGHT

HEATED AIR CURTAIN

HAND-OFF AUTOMATIC

HORSE POWER

HEAT PUMP (OUTDOOR PORTION OF SPLIT

SYSTEM HEAT PUMP, USE CU FOR

STANDARD DX OUTDOOR UNIT)

HEAT TRACKING

HEATING/VENTILATING UNIT

HEATING WATER CIRCULATING PUMP IN A

PRIMARY-SECONDARY SYSTEM

HEATING WATER SUPPLY IN A PRIMARY-ONLY

SYSTEM

HWRP

HWSP

HWUH

HZ

IDS

IMC

IRH

J OR JB

K

KAIC

KCM OR KCMIL

KEF

KH

KV

KVA

KW

KWHR

L

LA

LAN

LAV

LTG

MAU

MAX

MCA

MCB or MB

MCC

MGB

MH

MIN

MLO

MOD

MT or MTD

MRS

N

NEC

NEMA

NFPA

NC

NESC

NO

NTS

P

PA

PDU

PF

PH

PIU

PMT

PNL

PTAC

PVC

RECEPT or RECP

RF

RH

RMC

RMS

RTU

RVNR

SA

SCCR

SD

SF

S/N

SP

SPD

SPDT

SPEC

SPST

SWBD

SWGR

TMGB

TOL

TP

TYP

U

UH

UG

UIO

UL

UTP

V

VA

VAV

VEF

VM

VRF

W

WC

WEF

WH

WHDM

WSHP

WP

XFMR

Z

HOT WATER RECIRCULATION PUMP

HEATING WATER SUPPLY PUMP IN A PRIMARY-

SECONDARY SYSTEM

HOT WATER UNIT HEATER

HERTZ

INTRUSION DETECTION SYSTEM

INTERMEDIATE METAL CONDUIT

INFRARED HEATER

JUNCTION BOX

KILO

THOUSAND AMPERE INTERRUPTING CAPACITY

THOUSAND OF CIRCULAR MILS

KITCHEN EXHAUST FAN

KITCHEN HOOD

KILOVOLT

KILOVOLT-AMPERES

KILOWATT

KILOWATT-HOUR

LENGTH

LIGHTNING ARRESTOR

LOCAL AREA NETWORK

LAVATORY

LIGHTING

MAKE-UP AIR UNIT

MAXIMUM

MINIMUM CIRCUIT AMPACITY

MAIN CIRCUIT BREAKER

MOTOR CONTROL CENTER

MAIN GROUND BAR

MANHOLE or MOUNTING HEIGHT

MINIMUM

MAIN LUGS ONLY

MOTOR OPERATED DAMPER

MOUNT or MOUNTED

MOTOR RATED SWITCH

NEUTRAL

NATIONAL ELECTRICAL CODE

NATIONAL ELECTRICAL MANUFACTURER'S

ASSOCIATION

NATIONAL FIRE PROTECTION ASSOCIATION

NORMALLY CLOSED

NATIONAL ELECTRICAL SAFETY CODE

NORMALLY OPEN

NOT TO SCALE

POLE(S) or PUMP

PUBLIC ADDRESS

POWER DISTRIBUTION UNIT

POWER FACTOR

PHASE

VAV TERMINAL UNIT WITH PARALLEL OR

SERIES FAN (PRIMARY INDUCTION UNIT)

PAD MOUNTED TRANSFORMER

PANEL OR PANELBOARD

PACKAGED THRU-WALL AIR CONDITIONER

POLYVINYL CHLORIDE

RECEPTACLE

RETURN FAN

RADIANT HEATERS (ELECTRIC)

RIGID METAL CONDUIT

ROOT MEAN SQUARE

ROOF TOP UNIT

REDUCED VOLTAGE NON-REVERSING

SURGE ARRESTOR

SHORT CIRCUIT CURRENT RATING

SMOKE DAMPER

SUPPLY FAN

SOLID NEUTRAL

SUMP PUMP

SURGE PROTECTIVE DEVICE

SINGLE POLE DOUBLE THROW

SPECIFICATIONS

SINGLE POLE SINGLE THROW

SWITCHBOARD

SWITCHGEAR

TELECOMMUNICATIONS MAIN GROUNDING

BUSBAR

THERMAL OVERLOAD

TWISTED PAIR

TYPICAL

URINAL

UNIT HEATER

UNDERGROUND

UNLESS INDICATED OTHERWISE

UNDERWRITERS LABORATORY

UNSHIELDED TWISTED PAIR

VOLTS

VOLT AMPERES

VAV TERMINAL UNIT

VEHICLE EXHAUST FAN

VOLTMETER

VARIABLE REFRIGERANT FLOW SYSTEM

WATTS or WIRE or WIDTH

WATER CLOSET

WELDING EXHAUST FAN

WATER HEATER

WATTHOUR DEMAND METER

WATER SOURCE HEAT PUMP

WEATHERPROOF

TRANSFORMER

IMPEDANCE

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r vt

/1

/2

:4

:2

A

M

E-001

ELECTRICAL GENERAL NOTES

AND ABBREVIATIONS

RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

NOTE:

1. NOT ALL ABBREVIATIONS SHOWN WILL BE USED ON THIS

PROJECT.

WIRE SIZE FOR ALL 277V, 20A CIRCUITS,

UIO:

FOR ALL ONE-WAY CIRCUITS OF LENGTH OF LESS THAN 170 FT,

PROVIDE 2#12 & 1#12G, 3/4"C.

FOR ALL ONE-WAY CIRCUITS OF LENGTH OF LESS THAN 280 FT

AND GREATER THAN OR EQUAL TO 170 FT, PROVIDE 2#10 & 1#10G,

3/4"C.

FOR ALL ONE-WAY CIRCUITS OF LENGTH OF LESS THAN 440 FT

AND GREATER THAN OR EQUAL TO 280 FT, PROVIDE 2#8 & 1#8G,

3/4"C.

FOR ALL ONE-WAY CIRCUITS OF LENGTH OF LESS THAN 700 FT

AND GREATER THAN OR EQUAL TO 440 FT, PROVIDE 2#6 & 1#6G,

3/4"C.

WIRE SIZE FOR ALL 120V, 20A CIRCUITS,

UIO:

FOR ALL ONE-WAY CIRCUITS OF LENGTH OF LESS THAN 75 FT,

PROVIDE 2#12 & 1#12G, 3/4"C.

FOR ALL ONE-WAY CIRCUITS OF LENGTH OF LESS THAN 125 FT

AND GREATER THAN OR EQUAL TO 75 FT, PROVIDE 2#10 & 1#10G,

3/4"C.

FOR ALL ONE-WAY CIRCUITS OF LENGTH OF LESS THAN 190 FT

AND GREATER THAN OR EQUAL TO 125 FT, PROVIDE 2#8 & 1#8G,

3/4"C.

FOR ALL ONE-WAY CIRCUITS OF LENGTH OF LESS THAN 300 FT

AND GREATER THAN OR EQUAL TO 190 FT, PROVIDE 2#6 & 1#6G,

3/4"C.

NOTES:

1. ALL EXISTING EQUIPMENT IS SHOWN IN HALFTONE LINEWORK.

ALL DEMOLISHED EQUIPMENT IS SHOWN IN BOLD LINEWORK,

DASHED AND HATCHED. ALL NEW OR RELOCATED EQUIPMENT

IS SHOWN IN BOLD LINEWORK. BELOW IS AN EXAMPLE OF

EACH:

EXISTING EQUIPMENT

NEW OR RELOCATED EQUIPMENT

HATCH INDICATES EQUIPMENT TO BE DEMOLISHED

1/2

B

W

S B

M

MOD

2/60/40/1

60/40/3/3R

40/3/3R

CB

T

M

EM

J J

J

G

G4

LP

A

AE

M

X X

C

D a b

LUMINAIRES

LUMINAIRE AND OUTLET BOX. LETTER INDICATES

LUMINAIRE TYPE. SEE LIGHTING FIXTURE

SCHEDULE.

LUMINAIRE AND OUTLET BOX WIRED FOR

MULTILEVEL SWITCHING, LOWER CASE LETTER

INDICATES SWITCHLEG DESTINATION.

LUMINAIRE AND OUTLET BOX, WITH PROVISIONS

FOR EMERGENCY LIGHTING. LETTER INDICATES

LUMINAIRE TYPE. SEE LIGHTING FIXTURE

SCHEDULE.

WALL MOUNTED LUMINAIRE AND OUTLET BOX.

LETTER INDICATES LUMINAIRE TYPE. SEE

LIGHTING FIXTURE SCHEDULE.

CEILING OR WALL MOUNTED EXIT SIGN AND

OUTLET BOX. PROVIDE NUMBER OF ARROWS

AND FACES INDICATED. LETTER INDICATES

LUMINAIRE TYPE. SEE LIGHTING FIXTURE

SCHEDULE. WALL MT AT 96" AFF.

RECESSED OR PENDANT MOUNTED LUMINAIRE

AND OUTLET BOX. LETTER INDICATES LUMINAIRE

TYPE. SEE LIGHTING FIXTURE SCHEDULE.

WALL MOUNTED LUMINAIRE AND OUTLET BOX.

LETTER INDICATES LUMINAIRE TYPE. SEE

LIGHTING FIXTURE SCHEDULE.

CEILING OR WALL MOUNTED LUMINAIRE AND

OUTLET BOX WITH PROVISIONS FOR

EMERGENCY LIGHTING.

EMERGENCY LIGHT UNIT

REMOTE HEAD OR FLOOD LUMINAIRE

WALL WASH DOWNLIGHT

POLE MOUNTED TYPE

POST-TOP OR BOLLARD TYPE

CEILING FAN

EQUIPMENT

MOTOR, HORSEPOWER AS INDICATED

MOTORIZED DAMPER

3-POLE COMBINATION MAGNETIC MOTOR

STARTER/ DISCONNECT (NEMA SIZE/ FUSE SIZE/

NEMA ENCLOSURE) NF = NONFUSED

DISCONNECT SWITCH, (SWITCH AMPS/ FUSE

SIZE/ POLES/ NEMA ENCLOSURE) NF = NON-

FUSED

INDIVIDUALLY MOUNTED CIRCUIT BREAKER, (CB

SIZE/ POLES/ NEMA ENCLOSURE)

DRY TYPE TRANSFORMER, KVA AS INDICATED

METER

ELECTRONIC METER

PANELBOARD, SEE SCHEDULES

DISTRIBUTION PANELBOARD

EQUIPMENT AS INDICATED

CEILING OR WALL MOUNTED JUNCTION BOX

PULL OR JUNCTION BOX

CEILING MOUNTED BLUE LIGHT SYSTEM

ROTATING BEACON

WHITE NOISE PLENUM SPEAKER; MT ABOVE

DROP CEILING

BLUE LIGHT LOCAL CONTROL SWITCH; MT 48"

AFF, UIO

WHITE NOISE ROTARY VOLUME CONTROL; MT

48" AFF, UIO

LA-1,3,5

WIRING

CIRCUIT HOMERUN TO PANELBOARD, LA-1,3,5

ADJACENT TO ARROW INDICATES HOMERUN OF

CIRCUITS, 1,3,5 TO PANEL LA. MARKS ACROSS

RACEWAY INDICATE THE NUMBER OF PHASE

CONDUCTORS AND NEUTRAL IN RACEWAY.

GROUND CONDUCTORS ARE INDICATED BY

LONGER HASHMARKS. NO MARKS ACROSS

RACEWAY INDICATES 2#12 CONDUCTORS AND 1

#12 GROUND CONDUCTOR. CONDUCTOR SIZE #

12 UNLESS INDICATED OTHERWISE. MINIMUM

RACEWAY SIZE SHALL BE 3/4"

RACEWAY EXPOSED TO VIEW

CONCEALED RACEWAY, LOCATED IN WALL OR

ABOVE FINISHED CEILING

UNDERGROUND RACEWAY, LOCATED BELOW

GRADE OR CONCRETE SLAB

FLEXIBLE RACEWAY

RACEWAY TURNED TOWARD VIEWER

RACEWAY TURNED AWAY FROM VIEWER

RACEWAY TERMINATION, STUB-OUT AND CAP

PLUG-IN BUSWAY, UIO

SURFACE METAL RACEWAY OR MULTIOUTLET

ASSEMBLY AS INDICATED

CABLE TRAY (SIZE AS INDICATED ON PLAN)

DUCTBANK, TEXT INDICATES QUANTITY AND

SIZE OF DUCTS (I.E. 2W4" = TWO 4" DUCTS)

LIGHTNING PROTECTION

3/4" x 10'-0" COPPERCLAD GROUND ROD, 18" BFG

GROUND CONNECTION

BARE COPPER GROUND CONDUCTOR, 1/0 UIO.

4/0 BARE COPPER GROUND CONDUCTOR

LIGHTNING PROTECTION SYSTEM AIR TERMINAL

LIGHTNING PROTECTION ROOF CONDUCTOR

ELECTRICAL CONNECTION

SITE

ELECTRICAL MANHOLE

ELECTRICAL HANDHOLE

PAD MOUNTED TRANSFORMER

POWER POLE

DOWN GUY AND ANCHOR (QUANTITY AS

INDICATED)

ONE-LINE

TRANSFORMER

CURRENT TRANSFORMER

FUSE

ELECTRICAL CONNECTION

CIRCUIT BREAKER

SWITCH

SURGE ARRESTORS

SEPARABLE CONNECTION

DRY TYPE TRANSFORMER, K-4 RATED, KVA AS

INDICATED

GROUND ROD

GROUND

2W4"

WIRING DEVICES

SIMPLEX RECEPTACLE NEMA 5-20R, MT 18" AFF,

UIO

DUPLEX RECEPTACLE NEMA 5-20R, MT 18" AFF,

UIO

DUPLEX RECEPTACLE, NEMA 5-20R, MT 48" AFF

OR ABOVE COUNTER TOP/BACKSPLASH

DUPLEX GFI RECEPTACLE NEMA 5-20R, MT 18"

AFF, UIO

DUPLEX GFI RECEPTACLE NEMA 5-20R, MT 48"

AFF OR ABOVE COUNTER TOP/BACKSPLASH

DOUBLE-DUPLEX RECEPTACLE NEMA 5-20R, MT

18" AFF, UIO

SWITCHED DUPLEX RECEPTACLE NEMA 5-20R,

MT 18" AFF, UIO

SWITCHED DUPLEX RECEPTACLE NEMA 5-20R,

MT 48" AFF OR ABOVE COUNTER

TOP/BACKSPLASH

SWITCHED DUPLEX GFI RECEPTACLE NEMA

5-20R, MT 18" AFF, UIO

SWITCHED DUPLEX GFI RECEPTACLE NEMA

5-20R, MT 48" AFF OR ABOVE COUNTER

TOP/BACKSPLASH

DOUBLE-DUPLEX GFI RECEPTACLE, NEMA

5-20R, MOUNTED CONCEALED BEHIND ELECTRIC

WATER COOLER

FLOOR BOX WITH DUPLEX RECEPTACLE NEMA

5-20R. PROVIDE FIRE RATED POKE THRU

DEVICES ON ALL FLOORS ABOVE GROUND

LEVEL.

SPECIAL RECEPTACLE, NEMA TYPE AS

INDICATED, MT 18" AFF UIO

CEILING BOX WITH DUPLEX RECEPTACLE, NEMA

5-20R

RECEPTACLE WP = IN-USE WEATHER PROOF

SUBSCRIPTS TR = TAMPER RESISTANT

TV = TELEVISION, MOUNT AT 60" AFF

AFCI = ARC FAULT CIRCUIT INTERRUPTER

E = EMERGENCY CIRCUIT

FLOOR BOX SUITABLE FOR CONCRETE FLOOR

POUR; TWO COMPARTMENTS - POWER AND

TELECOMMUNICATIONS; FLUSH COVER/FLANGE

WITH HINGED ACCESS TO RECEPTACLES AND

JACKS RECESSED BELOW COVER IN FLOOR

BOX. PROVIDE 8" FIRE RATED POKE THRU

ABOVE GROUND FLOOR.

WALL SWITCH, AC TYPE, SPST, MOUNT 48" AFF

WALL SWITCH, AC TYPE, DPDT, MOUNT 48" AFF

3-WAY WALL SWITCH, MOUNT 48" AFF

4-WAY WALL SWITCH, MOUNT 48" AFF

SLIDE DIMMER, MT 48" AFF

MOTOR RATED DISCONNECT SWITCH WITH

THERMAL OVERLOADS, SPST, MT. ON UNIT, UIO.

WALL MOUNTED SPEAKER VOLUME SWITCH, MT.

48" AFF

WALL MOUNTED, DUAL TECHNOLOGY

OCCUPANCY SWITCH, MT. 48" AFF

LOW VOLTAGE ON/OFF WALL SWITCH, WALL MT.

48" AFF. PROVIDE DIMMER CONTROL WITH

DIMMABLE FIXTURES INTEGRAL WITH SWITCH.

CEILING MOUNTED DUAL TECHNOLOGY

OCCUPANCY SENSOR

CEILING MOUNTED DAYLIGHT SENSOR

ELECTRICAL LEGEND

D

M

V

O

LV

OS

DS

PE

5-30R

EWC

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r vt

/1

/2

:4

:2

A

M

E-002

ELECTRICAL LEGEND RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

NOTE:

1. NOT ALL SYMBOLS SHOWN WILL BE USED ON THIS PROJECT.

J

KEYNOTES:

2TL

2PT

2CP

XFMR T10

2CL

2CEP

2TP

EC

2C101COMM

2C100

CORR

C2-30

STAIR

NO 4

STAIR

NO 5

AREA OF WORK

2ND FLOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r vt

/1

/2

:4

:4

A

M

ED101

ELECTRICAL DEMOLITION PLAN RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

GENERAL NOTES:

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

KEY # KEYNOTE DESCRIPTION

SCALE: 1/8" = 1'-0"

F4

ELECTRICAL DEMOLITION PLAN

1. HATCH PATTERN INDICATES AREA OF DEMOLITION. DEMOLISH

ALL ELECTRICAL DEVICES, LIGHT FIXTURES AND CONTROLS,

CONDUIT AND CONDUCTORS WITHIN THIS AREA BACK TO

SOURCE PANELS.

2. REMOVE ALL CONNECTIONS TO MECHANICAL EQUIPMENT

BACK TO LOCAL JUNCTION BOX. PROTECT AND PRESERVE

DURING DEMOLITION. RE-USE EXISTING CIRCUITS FOR NEW

MECHANICAL EQUIPMENT INDICATED ON SHEET E-111.

3. PRESERVE AND PROTECT EXISTING 120V CRITICAL POWER

CIRCUIT "2CEP-2" FEEDING AUTOMATIC DOOR. DEMOLISH

BACK TO LOCAL JUNCTION BOX. RE-USE CIRCUIT FOR NEW

AUTOMATIC OPERATOR INDICATED ON SHEET E-111.

SCALE: = 1'-0"

0 8 168

1/8"

N

KEYPLAN

OS

OS

OS

OS

OS

OS OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

OS

Da

3Da

D D

D

D

D

D

Db 3Da

O

OS

OS

OS

OS

D

O

O

O O

O

O D

D

D d

O D

Da

D c

D

Db

D

Db

D

OS

PHYSICAL THERAPY

(PT)

2C111

WAITING

2C102

CHECK-IN DESK

2C103

PRIVATE

TREATMENT

2C104

STORAGE

2C105

DRIVER THERAPY

2C106

MEN (PATIENT)

2C108

WOMEN (PATIENT)

2C109

MULTI-PURPOSE

ROOM

2C107

CORRIDOR

C2-27

KINESIO-THERAPY

(KT)

2C112

OCCUPATIONAL

THERAPY (OT)

2C113 EQUIP. STORAGE

2C110

COMM

2C117

EL

2C118

CORRIDOR

C2-28

BREAKROOM

2C114

WOMEN (STAFF)

2C115

MEN (STAFF)

2C116

JAN

2C119

STORAGE

2C121

RECREATIONAL

THERAPY

2C120

A2E

A2

A2A2

A2 A2

A2 A2E

A1E

A1

A1

A1E

A1

A1

A1E

A1

A1

A2

A2E

A2 A2

A2E

A2

A2E

A2

A2

A3

A3E

A3

A1

A1 A1

A1

A2E

A1

A1

A1

A1

A1

A1

A1EA1A1

A1E

A1

A1

A2

A2E

A2

A2

A1 A2E A1

A1 A1 A1

D2

D1

D1

D1

A2

G

G

D1

GD1

X2 X2

X

X

STORAGE

2C114A

2CL-9EC

2C101

COMM

2C100

CORR

C2-30

STAIR

NO 4

STAIR

NO 5

D1

D1

D1 D1

A1

A1

A1

A2 a a aa aa bb bb aa a c d dc d d d

BE-19

d a a

STORAGE

2C111A

2TL-7

A22

A22

A22

A22

A22

A22 A22

A22 A22

AREA OF WORK

2ND FLOOR

STAIR

NO 4

STAIR

NO 4

CHARTING

2C113A

CHARTING

2C112A

KEYNOTES:

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r v t

/2

/2

:5

:4

P

M

E-101

LIGHTING AND PHOTOMETRIC

PLAN

RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

GENERAL NOTES:

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

2. REFER TO E-602 FOR LIGHTING FIXTURE SCHEDULE.

SCALE: 1/8" = 1'-0"F1

ELECTRICAL LIGHTING PLAN

SCALE: = 1'-0"

0 8 168

1/8"

N

KEYPLAN

SCALE: 1/8" = 1'-0"F5

ELECTRICAL LIGHTING PLAN PHOTOMETRICS

KEY # KEYNOTE DESCRIPTION

1. MOUNT SWITCES BELOW WINDOW AT 3'2" AFF.

POINT BY POINT PHOTOMETRIC CALCULATIONS

Calculation Points Name Average Maximum Minimum Maximum / Minimum

Calculation Points Height

PRIVATE TREATMENT 2C104 48 fc 78 fc 0 fc 219.1 3'-0"

KINESIO-THERAPY (KT) 2C112 28 fc 53 fc 10 fc 5.6 3'-0"

MULTI-PURPOSE ROOM 2C107 52 fc 69 fc 27 fc 2.5 2'-6"

WAITING 2C102 31 fc 57 fc 0 fc 187502.3 2'-6"

CORRIDOR C2-27 19 fc 23 fc 11 fc 2.0 0'-0"

CORRIDOR C2-28 20 fc 24 fc 16 fc 1.5 0'-0"

CHECK-IN DESK 2C103 67 fc 108 fc 27 fc 3.9 3'-0"

WOMEN 2C115 31 fc 38 fc 25 fc 1.5 1'-6"

MEN 2C116 30 fc 38 fc 14 fc 2.8 1'-6"

WOMEN (STAFF) 2C109 28 fc 39 fc 9 fc 4.4 1'-6"

MEN (STAFF) 2C108 22 fc 40 fc 0 fc 370.0 1'-6"

JAN 2C119 27 fc 29 fc 25 fc 1.2 0'-0"

STORAGE 2C121 22 fc 26 fc 18 fc 1.4 0'-0"

BREAKROOM 2C114 20 fc 46 fc 0 fc 112050.8 2'-6"

RECREATIONAL THERAPY 2C120 35 fc 63 fc 22 fc 2.9 3'-0"

EQUIP. STORAGE 2C110 17 fc 25 fc 0 fc 1063.6 0'-0"

DRIVER THERAPY 2C106 41 fc 68 fc 24 fc 2.8 3'-0"

STORAGE 2C111A 14 fc 19 fc 3 fc 5.5 0'-0"

PHYSICAL THERAPY (PT) 2C111 35 fc 63 fc 1 fc 105.2 3'-0"

STORAGE-2 2C114A-2 25 fc 33 fc 0 fc 3040.3 0'-0"

STORAGE 2C105 6 fc 16 fc 0 fc 821.4 0'-0"

CHARTING 2C112A 9 fc 44 fc 0 fc 858.8 3'-0"

CHARTING 2C113A 17 fc 42 fc 2 fc 19.3 3'-0"

OCCUPATIONAL THERAPY (OT) 2C113 30 fc 57 fc 0 fc 542.4 3'-0"

REF.

PP

PP

J

J J

J

J J

J

J

J

J

KEYNOTES:

2TL

2CEP

2CL

XFMR T10

2CP

2PT

PHYSICAL THERAPY

(PT)

2C111

WAITING

2C102

CHECK-IN DESK

2C103

PRIVATE

TREATMENT

2C104

STORAGE

2C105

DRIVER THERAPY

2C106

MULTI-PURPOSE

ROOM

2C107

MEN (PATIENT)

2C108

WOMEN (PATIENT)

2C109

CORRIDOR

C2-27

KINESIO-THERAPY

(KT)

2C112

OCCUPATIONAL

THERAPY (OT)

2C113

EQUIP. STORAGE

2C110

COMM

2C117

EL

2C118

CORRIDOR

C2-28

WOMEN (STAFF)

2C115

MEN (STAFF)

2C116

JAN

2C119

STORAGE

2C121

RECREATIONAL

THERAPY

2C120

BREAKROOM

2C114

+60"

2CP-3

2CP-13

2TP

2CP-6

2CP-21

2CP-17

2PT-3

+60"

2CP-15

2TP-12

2TP-13

2TP-14

2TP-11

STORAGE

2C114A

EC

2C101

COMM

2C100

CORR

C2-30

STAIR

NO 4

STAIR

NO 5

2CP-4

2TP-10

2TP-8

2TP-9

2CP-19

2PT-1

2TP-15

2TP-17

+60"

+60"

2TP-16

EWC

2CP-8

2TP-18

2TP-19

2PT-2

2PT-5

2CP-5

2PT-4

2PT-6

2PT-7

2CP-1

2CP-3

2TP-7

2CP-23

2CEP-9

AREA OF WORK

2ND FLOOR

VAV-8-9

VAV-8-10

VAV-8-8

VAV-8-7

VAV-8-6

VAV-8-5

VAV-8-2

VAV-8-1

VAV-8-3

VAV-8-4

EC

2C101COMM

2C100

CORR

C2-30

STAIR

NO 4

STAIR

NO 5

PHYSICAL THERAPY

(PT)

2C111

WAITING

2C102

CHECK-IN DESK

2C103

PRIVATE

TREATMENT

2C104

STORAGE

2C105

DRIVER THERAPY

2C106

MULTI-PURPOSE

ROOM

2C107

MEN (PATIENT)

2C108

WOMEN (PATIENT)

2C109

CORRIDOR

C2-27

EQUIP. STORAGE

2C110

CORRIDOR

C2-28

BREAKROOM

2C114

STORAGE

2C114A

RECREATIONAL

THERAPY

2C120

MEN (STAFF)

2C116

JAN

2C119

STORAGE

2C121

EL

2C118

COMM

2C117

KINESIO-THERAPY

(KT)

2C112

OCCUPATIONAL

THERAPY (OT)

2C113

STORAGE

2C111A

CHARTING

2C112A

SD

CHARTING

2C113A

SD

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r v t

/2

/2

:4

:5

P

M

E-111

POWER PLAN RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

GENERAL NOTES:

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

KEY # KEYNOTE DESCRIPTION

SCALE: 1/8" = 1'-0"F1

POWER PLAN

SCALE: = 1'-0"

0 8 168

1/8"

N

KEYPLAN

1. PROVIDE 120V, 2.5A CONNECTION IN ACCESSIBLE CEILING TO

BED LIFT CHARGER. COORDINATE EXACT LOCATION WITH

EQUIPMENT PROVIDER.

2. PROVIDE (2) DUPLEX RECEPTACLES MOUNTED IN AN

ALUMINUM 2" x 12 'x 2" POWER POLE FOR EQUIPMENT POWER.

COORDINATE EXACT LOCATION OF POWER POLE WITH

EQUIPMENT. PRIOR TO INSTALLATION.

3. REUSE EXISTING CRITICAL POWER 120V CIRCUIT 2CEP-2 FOR

CONNECTION TO NEW AUTOMATIC DOOR.

4. RE-USE EXISTING LIFE SAFETY CIRCUIT FEEDING NURSE CALL

IN SPACE TO FEED NEW NURSE CALL CONTROL PANEL.

REFER TO SHEET T-101.

5. RE-USE EXISTING HVAC CIRCUITS, OVERCURRENT

PROTECTION, AND LOCAL DISCONNECTING MEANS

PRESERVED DURING DEMOLITION WHERE POSSIBLE. PULL

POWER FROM NEAREST 120V J-BOX. ENSURE SATISFACTION

OF REQUIREMENTS FOR NEW EQUIPMENT BEFORE

CONNECTING TO NEW VAV.

6. PROVIDE 120V/1P 20A EMERGENCY EQUIPMENT CIRCUIT

FROM PANEL 2BE TO NEW FIRE SMOKE DAMPERS. REFER TO

SHEET E-603 FOR MORE INFORMATION.

7. PROVIDE 3/4" CONDUIT FROM AUTOMATIC DOOR TO EXISTING

PUSHPLATE BOX. RE-USE EXISTING BOX IN EXISTING

LOCATION.

8. REUSE EXISTING CONDUIT FROM AUTOMATIC DOOR TO PUSH

PLATE LOCATED ON BOLLARD.

9. PROVIDE 120V CRITICAL BRANCH POWER TO FIRE ALARM NAC

PANEL.

TYP

SCALE: 1/8" = 1'-0"F5

MECHANICAL EQUIPMENT POWER PLAN

TV

TV TV

MAX.

6"

MAX.

6"

AV

MAX.

12"

F

IR

E

F

IR

E

FIRE

ALARM

DATA

OUTLET

MAX.

12"

" POWER

RECEPTACLE

T-STAT

T $

LIGHT

SWITCH

OR OS

SWITCH

VOICE

OUTLET

MAX.

6"

12" MAX.

PROJECTOR

MOMENTARY

TOGGLE

SWITCH

18" MAX. 6"

~ M A

R K

E R

B O

A R

D

6" MIN.

FIRE ALARM

PULL STATION

P

(EITHER SIDE OF DOOR)

5'-0" MAX.

M

IN

M E

A S

U R

E D

T O

H A

N D

L E

POWER

RECEPTACLE

6" MIN.

6" MIN.

B O

T T

O M

O F

L E

N S

A F

F M

IN

T O

P O

F L

E N

S

A

F F

M A

X

FLOOR

CEILING

FACEPLATE COLOR PER

SPECIFICATION 26 27 26

PNL-CKT

CLEAR LABEL TAPE WITH

TYPED, BLACK LETTERING

DESIGNATING PANEL AND

CIRCUIT NUMBER.

PROVIDE RECEPTACLES IN THE

FOLLOWING COLORS:

• WHITE: NORMAL POWER

• RED: CRITICAL POWER

PROVIDE DURABLE

WIRE MARKERS OR

TAGS INSIDE THE

OULET BOX.

INSTALL GROUND PIN

ON TOP

FACEPLATE COLOR PER

SPECIFICATION 26 09 23

PNL-CKT

CLEAR LABEL TAPE WITH

TYPED, BLACK LETTERING

DESIGNATING PANEL AND

CIRCUIT NUMBER.

PROVIDE DURABLE

WIRE MARKERS OR

TAGS INSIDE THE

OUTLET BOX.

NOTES:

1.

2.

INSTALLATION IS ACCEPTABLE ALTERNATE TO DETAIL SD260533-01.

INSTALLATION IS REQUIRED FOR CONDUIT 76mm (3") AND LARGER.

PROVIDE EXTRA CABLE TO

MAKE COMPLETE LOOP

AROUND BOX PERIMETER

SPRING NUT

CONDUIT

TRAPEZE PER SD26D533-03,

TYP.

EXPANSION FITTING

WITH BONDING JUMPER

FLOOR OR ROOF

STRUCTURE. FIELD VERIFY

ACTUAL CONDITIONS, TYP.

HEAD

CONDUIT,

TYP.

SEISMIC OR EXPANSION

JOINT. FIELD VERIFY ACTUAL CONDITIONS &

LOCATIONS

INSULATION

BUSHING

STEEL EXPANSION

JOINT

STRUCTURAL MEMBER

(BEAM, JOIST, ETC.), TYP.

JUNCTION BOX, TYP.

(SIZE AS REQUIRED)

INTEGRAL GALVANIZED

LIPPED STEEL

MOUNTING CHANNEL

JUNCTION BOX, TYP.

(SIZE AS REQUIRED)

CONDUIT FITTING

BEAM

CLAMP

TYP.

914mm

(3'-0") - MAX

LENGTH AS REQUIRED

CONDUIT CLAMP.

SIZE AS REQUIRED

INTEGRAL

GALVANIZED

LIPPED STEEL

MOUNTING

CHANNEL

REFER TO PLANS FOR

QUANTITY & SIZE OF

CONDUITS

NOTES:

1.

2.

3.

INTEGRAL GALVANIZED LIPPED STEEL MOUNTING CHANNEL LONGER THAN 915mm (36") SHALL BE

INSTALLED WITH A CENTER SUPPORT ROD.

FASTEN THREADED ROD TO STRUCTURE BY APPROVED METHOD PER SPECIFICATION 26 05 33,

RACEWAY AND BOXES FOR ELECTRICAL SYSTEMS. FIELD VERIFY EXACT CONDITIONS.

FOR TRAPEZE INSTALLATIONS IN SEISMIC AREAS REFER TO SPECIFICATION SECTION 13 05 41, SEISMIC RESTRAINT REQUIREMENTS FOR NON-STRUCTURAL COMPONENTS.

LOCKING SQUARE

WASHER & LOCKNUT

9.52mm (3/8") MIN

GALVANIZED THREADED

ROD, TYP.

WASHER &

LOCKNUT

INTEGRAL

GALVANIZED

LIPPED STEEL

MOUNTING

CHANNEL

SCALE: N.T.S.F1

MOUNTING HEIGHT DETAIL

GENERAL NOTES:

SCALE: N.T.S.C1

RECEPTACLE DETAIL (TYP.)

SCALE: N.T.S.C4

LIGHT SWITCH DETAIL (TYP.)

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r vt

/1

/2

:4

:3

A

M

E-501

ELECTRICAL DETAILS RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

SCALE: N.T.S.C6

CONDUIT EXPANSION JOINT CROSSING DETAIL

SCALE: N.T.S.F6

CONDUIT TRAPEZE MOUNTING DETAIL

LUMINAIRE MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION 26 51 00

GYPSUM BOARD

CEILING HANGER

WIRE, TYP.

WIRE TIE OR SCREW

BAR HANGER TO

CROSS BEAM TYP.

CEILING

CROSS BEAM

CEILING

MAIN BEAM

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6") LONG MAX)

LUMINAIRE

BAR HANGERS

RECESSED CAN

LUMINAIRE

CEILING

BEAM

RECESSED

CAN LUMINAIRE

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6") LONG MAX)

ARCHITECTURAL

CEILING GRID

WIRE TIE OR SCREW

BAR HANGER TO

CROSS BEAM TYP.

CEILING HANGER

WIRE, TYP.

RECESSED

CAN LUMINAIRE

ACOUSTICAL

CEILING TILE (TYP.)

RECESSED CAN

LUMINAIRE

ARCHITECTURAL

CEILING GRID

LUMINAIRE

BAR HANGERS

LUMINAIRE MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION 26 51 00

6.35mm (1/4") SCREW

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM, TYP.

CEILING MAIN

BEAM

GYPSUM

BOARD

DRYWALL CEILING

CROSS TEE, TYP.

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6") LONG MAX)

HANGER WIRE AND MOUNTING

CHANNEL ATTACHED TO STRUCTURE

REFER TO SPECIFICATION SECTION

26 51 00

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

CEILING HANGER WIRE

DRYWALL CEILING

CROSSING TEE, TYP.

6.35mm (1/4") SCREW

JUNCTION BOX

LOCKING SQUARE

WASHER & NUT

WIRE TIE THROUGH

MOUNTING CHANNEL

& CROSS BEAM, TYP.

ARCHITECTURAL

CEILING GRID

ACOUSTICAL

CEILING TILE

(TYP.)

ARCHITECTURAL

CEILING GRID

FIXTURE WHIP FROM

JUNCTION BOX

(1829mm (6") LONG MAX)

HANGER WIRE AND MOUNTING

CHANNEL ATTACHED TO STRUCTURE

REFER TO SPECIFICATION SECTION

26 51 00

INTEGRAL GALVANIZED LIPPED

STEEL MOUNTING CHANNEL

CEILING HANGER WIRE

ARCHITECTURAL

CEILING GRID

LUMINAIRE

SUSPENSION WIRES

REFER TO

SPECIFICATION

SECTION 26 51 00

3 TWIST

MINIMUM (TYP)

FIXTURE WHIP

FROM JUNCTION BOX

(1829mm (6') LONG MAX.)

CEILING MAIN BEAM

GYPSUM BOARD (TYP)

LUMINAIRE. REFER

TO SCHEDULE

LUMINAIRE MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION 26 51 00

CEILING CROSS BEAM

GYPSUM BOARD

CEILING CROSS BEAM

LUMINAIRE. REFER

TO SCHEDULE

DRYWALL

BORDER

LUMINAIRE

SUSPENSION WIRES

REFER TO

SPECIFICATION

SECTION 26 51 00

3 TWIST

MINIMUM (TYP)

FIXTURE WHIP

FROM JUNCTION BOX

(1829mm (6') LONG MAX.)

LUMINAIRE. REFER

TO SCHEDULE

LUMINAIRE MANUFACTURER'S

MOUNTING HARDWARE

REFER TO SPECIFICATION

SECTION 26 51 00

ACOUSTICAL

CEILING TILE (TYP.)

LUMINAIRE. REFER

TO SCHEDULE

ARCHITECTURAL

CEILING GRID

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r vt

/1

/2

:4

:3

A

M

E-502

ELECTRICAL DETAILS RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

GENERAL NOTES:

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

SCALE: N.T.S.C1

DOWNLIGHT MOUNTING - GYPBOARD CEILING DETAIL

SCALE: N.T.S.C4

DOWNLIGHT MOUNTING - LAY-IN CEILING DETAIL

SCALE: N.T.S.C7

EXIT SIGN MOUNTING - GYPBOARD CEILING DETAIL

SCALE: N.T.S.F1

EXIT SIGN MOUNTING - LAY-IN CEILING DETAIL

SCALE: N.T.S.F4

LUMINAIRE MOUNTING - GYPBOARD CEILING DETAIL

SCALE: N.T.S.F7

LUMINAIRE MOUNTING - LAY-IN CEILING DETAIL

2PT

30A

MCB

T17

9 KVA

480:

208/120V

TO

EXISTING

XFMR T16

EXISTING PANEL ICL 480V

A

/3 P

A

/3 P

A

/3 P

A

/3 P

EXISTING

PANEL 2TL 480V

A

/3 P

A

/3 P

T10

30 KVA

480:

208/120V

EXISTING

PANEL 2CL 480V

A

/3 P

A

/3 P

2CP

70A

MCB

2PT

40A

MCB

EXISTING PARTIAL NORMAL POWER BRANCH ONE-LINE DIAGRAM

2CEP

100A

MLO

T18

15 KVA

480:

208/120V

TO

EXISTING

XFMR T21

EXISTING PANEL BE 480V

A

/3 P

A

/3 P

A

/3 P

EXISTING

PANEL ICEP 480V

A

/3 P

A

/3 P

EXISTING PARTIAL LIFE SAFETY/CRITICAL BRANCH ONE-LINE DIAGRAM

EXISTING PANEL MDP 480V

A

/3 P

A

/3 P

EXISTING 4000A SWITCHBOARD BUSS

A

/3 P

A

/3 P

4000A CL FUSE

TO UTILITY TRANSFORMERS

EXISTING PANEL DE 480V

A

/3 P

ATS-2

TO EXISTING

PANEL ESB 480V

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r vt

/1

/2

:4

:3

A

M

E-601

ELECTRICAL ONE-LINE DIAGRAM RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

GENERAL NOTES:

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

SCALE: N.T.S.F2

EXISTING ELECTRICAL ONE-LINE DIAGRAM

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r vt

/1

/2

:4

:4

A

M

E-602

LIGHT FIXTURE SCHEDULE RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

LIGHTING FIXTURE SCHEDULE

FIXTURE DESCRIPTION LAMP LUMENS CRI CCT VOLTAGE WATTAGE MOUNTING MANUFACTURER NOTES

A1 2'X4' RECESSED DIMMABLE LED FIXTURE LED 2962 80+ 3500K 277 V 23 W GRID RECESSED LITHONIA LIGHTING 2BTL4-30L-EZ1-LP835 1,2

A1E 2'X4' RECESSED DIMMABLE LED FIXTURE LED 2962 80+ 3500K 277 V 23 W GRID RECESSED LITHONIA LIGHTING 2BTL4-30L-EZ1-LP835 1,2

A2 2'X4' RECESSED DIMMABLE LED FIXTURE LED 6016 80+ 3500K 277 V 48 W GRID RECESSED LITHONIA LIGHTING 2BTL4-60L-EZ1-LP835 1,2

A2E 2'X4' RECESSED DIMMABLE LED FIXTURE LED 6016 80+ 3500K 277 V 48 W GRID RECESSED LITHONIA LIGHTING 2BTL4-60L-EZ1-LP835 1,2

A3 2'X4' RECESSED DIMMABLE LED FIXTURE LED 7148 80+ 3500K 277 V 61 W GRID RECESSED LITHONIA LIGHTING 2BTL4-72L-EZ1-LP835 1,2

A3E 2'X4' RECESSED DIMMABLE LED FIXTURE LED 7148 80+ 3500K 277 V 61 W GRID RECESSED LITHONIA LIGHTING 2BTL4-72L-EZ1-LP835 1,2

A22 2'X2' RECESSED DIMMABLE LED FIXTURE LED 3987 80+ 3500K 277 V 32 W GRID RECESSED LITHONIA LIGHTING 2BTL2-40L-EZ1-LP835 1,2

D1 LED DOWNLIGHT LED 1082 80 3500K 277 V 13 W GRID RECESSED LITHONIA LIGHTING LDN6-35-10-LO6-AR-LSS-MVOLT-GZ10 1,2

D2 LED DOWNLIGHT LED 2023 80 3500K 277 V 23 W GRID RECESSED LITHONIA LIGHTING LDN6-35-20-LO6-AR-LSS-MVOLT-GZ10 1,2

G 10" CYLINDRICAL ARCHITECTURAL PENDANT LED 1100 80 3500K 277 V 20 W PENDANT, 12" CABLE USAI LIGHTING LNRP3-9020-M2-SN-SN-10-35KS-10-SOC-12-277-DIML2 1,2

X LED CAST ALUMINUM EXIT SIGN LED 277 V 10 W UNIVERSAL LITHONIA LIGHTING LE S 1/2 R EL N 1,3

X2 LED CAST ALUMINUM EXIT SIGN LED 277 V 10 W UNIVERSAL LITHONIA LIGHTING LE S 1/2 R EL N 1,3

NOTES:

1. DESIGN BASIS SHOWN FOR REFERENCE ONLY. FIXTURES OF EQUAL QUALITY AND PERFORMANCE ARE ACCEPTABLE. ALL FIXTURES MUST BE EQUAL IN MATERIAL, QUALITY, WARRANTY, PHOTOMETRIC, SIZE AND FINISH.

2. VERIFY CEILING TYPES WITH ARCHITECTURAL DRAWINGS PRIOR TO ORDERING.

3. WIRE EXIT SIGNS AHEAD OF ALL LOCAL SWITCHING.

GENERAL NOTES:

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL SHEET SIZE: 30" X 42"

B

IM

/1

V

A B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a

/1

V A

B ld g

M E

P

F P

V

.r vt

/1

/2

:4

:4

A

M

E-603

PANELBOARD SCHEDULES RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

04/22/2020 TEH MJW

GENERAL NOTES:

1. REFER TO E-001 & E-002 FOR ELECTRICAL GENERAL NOTES,

ABBREVIATIONS & LEGEND.

2. HALF-TONE (GRAY) TEXT INDICATES EXISTING CIRCUIT

AND/OR LOAD.

NOTES:

TOTAL LOAD: 1.21 0.00 0.00 TOTAL CONNECTED LOAD: 1.5 A

19 SPACE -- -- 0.00 0.00 -- -- SPACE 20

17 SPACE -- -- 0.00 0.00 -- -- SPACE 18

15 SPARE (OFF) 20.0 A 1 0.00 0.00 -- -- SPACE 16

13 SPARE (OFF) 20.0 A 1 0.00 0.00 -- -- SPACE 14

11 LIGHTS OUTSIDE YY FIXTURES 20.0 A 1 0.00 0.00 -- -- -- 12

9 LIGHTS OUTSIDE TERRACE... 20.0 A 1 0.00 0.00 -- -- -- 10

7 LIGHTS 2C110, 2C112, 2C113,... 20.0 A 1 1.21 0.00 3 15.0 A XFMR 2TL 8

5 -- -- -- 0.00 0.00 -- -- SPACE 6

3 -- -- -- 0.00 0.00 -- -- SPACE 4

1 MAIN 40.0 A 3 0.00 0.00 -- -- SPACE 2

CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: VOLTAGE: 480Y/277

LOCATION: EL 2C118 MAINS RATING: 40A MCB MINIMUM BREAKER SCCR:

PANELBOARD SCHEDULE 2TL

NOTES:

TOTAL LOAD: 2.28 1.08 1.56 TOTAL CONNECTED LOAD: 13.7 A

17 SPACE -- -- 0.00 0.00 -- -- -- 18

15 NEW SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 2 30.0 A WELDER OUTLET 2C101 16

13 NEW SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A TLS XFMR 14

11 NEW SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A SPARE (OFF) 12

9 NEW SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A REC RM 2D101 10

7 REC 2C111 20.0 A 1 0.18 0.00 1 20.0 A NEW SPARE (TURN TO OFF) 8

5 REC 2C112 20.0 A 1 1.20 0.36 1 20.0 A REC 2C111 6

3 REC 2C107 20.0 A 1 0.90 0.18 1 20.0 A REC 2C111 4

1 REC 2C106 20.0 A 1 0.90 1.20 1 20.0 A REC 2C112 2

CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: VOLTAGE: 208Y/120

LOCATION: MAINS RATING: 40A MCB MINIMUM BREAKER SCCR:

PANELBOARD SCHEDULE 2PT

NOTES:

TOTAL LOAD: 0.00 0.80 0.00 TOTAL CONNECTED LOAD: 1.0 A

19 SPACE -- -- 0.00 0.00 -- -- SPACE 20

17 SPARE (OFF) 20.0 A 1 0.00 0.00 -- -- SPACE 18

15 SPARE (OFF) 20.0 A 1 0.00 0.00 -- -- SPACE 16

13 LIGHTS RM 2D101, PENTHOUSE 20.0 A 1 0.00 0.00 -- -- SPACE 14

11 LIGHTS CORR 27, 30 RM... 20.0 A 1 0.00 0.00 -- -- -- 12

9 LIGHTS CORR C2-27, C2-28,... 20.0 A 1 0.80 0.00 -- -- -- 10

7 LIGHTS ELEVATOR LOBBY COR... 20.0 A 1 0.00 0.00 3 40.0 A 30KVA XFMR 8

5 SPACE -- -- 0.00 0.00 -- -- -- 6

3 SPACE -- -- 0.00 0.00 -- -- -- 4

1 SPACE -- -- 0.00 0.00 3 60.0 A MAIN 2

CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: VOLTAGE: 480Y/277

LOCATION: MAINS RATING: 60A MCB MINIMUM BREAKER SCCR:

PANELBOARD SCHEDULE 2CL

NOTES:

TOTAL LOAD: 4.83 2.16 3.54 TOTAL CONNECTED LOAD: 29.2 A

35 -- -- -- 0.00 0.00 1 20.0 A SPARE(OFF) 36

33 FAN RV-5 (ON) 30.0 A 2 0.00 0.00 1 20.0 A SPARE (OFF) 34

31 REC UNKNOWN LOAD (ON) 20.0 A 1 0.00 0.00 1 20.0 A SPARE (OFF) 32

29 REC UNKNOWN LOAD (ON) 20.0 A 1 0.00 0.00 1 15.0 A UNKNOWN LOAD (ON) 30

27 NEW SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A NEW SPARE (TURN TO OFF) 28

25 NEW SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A NEW SPARE (TURN TO OFF) 26

23 NEW SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A NEW SPARE (TURN TO OFF) 24

21 NEW SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A NEW SPARE (TURN TO OFF) 22

19 REC 2C113 20.0 A 1 0.18 0.00 1 20.0 A NEW SPARE (TURN TO OFF) 20

17 REC ICE MACHINE 2C114 20.0 A 1 1.20 0.36 1 20.0 A REC 2C113 18

15 REC 2C114 20.0 A 1 0.90 0.36 1 20.0 A REC TV'S 2C120 16

13 REC 2C120 20.0 A 1 3.12 0.09 1 20.0 A REC 2C114 14

11 REC 2C120 20.0 A 1 0.90 1.08 1 20.0 A REC 2C121 12

9 REC EQUIP. STORAGE 2C110 20.0 A 1 0.36 0.54 1 20.0 A REC 2C110 10

7 REC 2C113B 20.0 A 1 0.90 0.54 1 20.0 A REC 2C110 8

5 SPACE -- -- 0.00 0.00 -- -- -- 6

3 SPACE -- -- 0.00 0.00 -- -- -- 4

1 SPACE -- -- 0.00 0.00 3 30.0 A MAIN 2

CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: VOLTAGE: 208Y/120

LOCATION: EL 2C118 MAINS RATING: 30A MCB MINIMUM BREAKER SCCR:

PANELBOARD SCHEDULE 2TP

NOTES:

TOTAL LOAD: 3.06 4.44 2.86 TOTAL CONNECTED LOAD: 28.8 A

41 SPARE (OFF) 20.0 A 1 0.00 0.00 1 20.0 A SPARE (OFF) 42

39 SPARE (OFF) 20.0 A 1 0.00 0.00 1 20.0 A SPARE (OFF) 40

37 SPARE (OFF) 20.0 A 1 0.00 0.00 1 20.0 A TV RACK POWER RM 1C102 38

35 SPACE -- -- 0.00 0.00 1 20.0 A SOUND RACK POWER RM 1C102 36

33 LIGHT TRACK COVERED LIGHT... 20.0 A 1 0.00 0.00 1 20.0 A SOUND RACK POWER RM 1C102 34

31 LIGHT TRACK COVERED LIGHT... 20.0 A 1 0.00 0.00 1 20.0 A SOUND RACK POWER RM 1C102 32

29 LIGHT TRACK COVERED LIGHT... 20.0 A 1 0.00 0.00 1 20.0 A UNKNOWN LOAD (ON) 30

27 LIGHT TRACK COVERED LIGHT... 20.0 A 1 0.00 0.00 -- -- SPACE 28

25 REC CORR C2-30 20.0 A 1 0.00 0.00 1 20.0 A FAN 7-RV1 1/3 HP 26

23 REC 2C111 20.0 A 1 0.18 0.00 1 20.0 A REC RM 2C106 EAST WALL 24

21 REC 2C102 20.0 A 1 0.90 0.00 1 20.0 A REC RM 2D100 22

19 REC 2C106 20.0 A 1 1.20 0.00 1 20.0 A REC RM 2D100 20

17 REC 2C106 20.0 A 1 1.08 0.00 1 20.0 A REC LOUNGE C2-24, C2-19, 18

15 CEILING HOIST 2C113 20.0 A 1 1.56 0.00 1 20.0 A REC RM 2C122, 123, CORR C2-30 16

13 REC 2C112 20.0 A 1 0.54 0.00 1 20.0 A REC EDF CORR C2-30 14

11 NEW GFCI SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A NEW SPARE (TURN TO OFF) 12

9 NEW GFCI SPARE (TURN TO OFF) 20.0 A 1 0.00 0.00 1 20.0 A NEW GFCI SPARE (TURN TO OFF) 10

7 NEW GFCI SPARE (TURN TO OFF) 20.0 A 1 0.00 0.60 1 20.0 A ELECTRIC WATER FOUNTAIN 8

5 REC 2C112 20.0 A 1 0.18 1.42 1 20.0 A REC 2C104 6

3 REC 2C111 20.0 A 1 0.90 1.08 1 20.0 A REC 2C112 4

1 REC 2C111 20.0 A 1 0.72 0.00 1 20.0 A NEW GFCI SPARE (TURN TO OFF) 2

CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: VOLTAGE: 208Y/120

LOCATION: MAINS RATING: 70A MCB MINIMUM BREAKER SCCR:

PANELBOARD SCHEDULE 2CP

NOTES:

TOTAL LOAD: 0.00 0.52 0.00 TOTAL CONNECTED LOAD: 1.4 A

11 UNKNOWN LOAD (ON) 20.0 A 1 0.00 0.00 1 20.0 A FIRE ALARM STROBE POWER 12

9 FACP NAC PANEL 20.0 A 1 0.52 0.00 1 20.0 A FIRE ALARM DVC/NCA/ VOICE... 10

7 REC 2C118 20.0 A 1 0.00 0.00 1 20.0 A REC 2D101 8

5 REC 2C117 20.0 A 1 0.00 0.00 1 20.0 A AUTO DOORS CORR C2-24, C2-19 6

3 REC 2C100 20.0 A 1 0.00 0.00 1 20.0 A AUTO DOORS CORR C2-23 4

1 REC 2C101 20.0 A 1 0.00 0.00 1 20.0 A AUTO DOORS CORR C2-29, C2-27 2

CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: VOLTAGE: 208Y/120

LOCATION: MAINS RATING: 100A MLO MINIMUM BREAKER SCCR:

PANELBOARD SCHEDULE 2CEP

EL 2C101

EL 2C101

EL 2C101

EL 2C101

NORMAL NORMAL

NORMAL

NORMAL

NORMAL

CRITICAL

NOTES:

TOTAL LOAD: 0.60 0.00 0.00 TOTAL CONNECTED LOAD: 0.7 A

23 SPARE 20.0 A 1 0.00 0.00 -- -- -- 24

21 SPARE 20.0 A 1 0.00 0.00 -- -- -- 22

19 LIGHTING SCI REHAB AREA 20.0 A 1 0.60 0.00 3 40.0 A 30 KVA XFMR (PANEL 1CEP) 20

17 EXIT LIGHTS 20.0 A 1 0.00 0.00 -- -- -- 18

15 EXIT LIGHTS 20.0 A 1 0.00 0.00 -- -- -- 16

13 SPARE ( TURNED ON) 20.0 A 1 0.00 0.00 3 30.0 A PANEL BCE 14

11 FIRST FLOOR E-SECTION CORR 20.0 A 1 0.00 0.00 1 20.0 A COOR LIGHTS 12

9 COORM RMS... 20.0 A 1 0.00 0.00 1 20.0 A LIGHTS FIRST FLOOR SECTION C 10

7 CORR, LIGHTS, LOBBY CB24 20.0 A 1 0.00 0.00 1 20.0 A LIGHTS SECOND FLOOR 8

5 SPACE -- -- 0.00 0.00 -- -- -- 6

3 SPACE -- -- 0.00 0.00 -- -- -- 4

1 SPACE -- -- 0.00 0.00 3 70.0 A MAIN 2

CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: VOLTAGE: 480Y/277

LOCATION: MAINS RATING: 60A MCB MINIMUM BREAKER SCCR:

PANELBOARD SCHEDULE BECRITICAL

EL BC115

1. CONTRACTOR TO VERIFY EXISTING SCCR RATING. CONTRACTOR TO PROVIDE NEW BREAKERS IN ACCORDANCE WITH THIS RATING.

2. CONTRACTOR TO PROVIDE A 30 DAY METERING OF THE PANEL MAIN PRIOR TO INSTALLATION OF NEW CIRCUIT. CONTRACTOR TO VERIFY EXISTING METERED DEMAND x 125% PLUS NEW LOAD DOES NOT EXCEED 80% OF PANEL FEEDER RATING.

SEE NOTE 1

1. CONTRACTOR TO VERIFY EXISTING SCCR RATING. CONTRACTOR TO PROVIDE NEW BREAKERS IN ACCORDANCE WITH THIS RATING.

2. CONTRACTOR TO PROVIDE A 30 DAY METERING OF THE PANEL MAIN AND A 30 DAY METER OF EACH INDIVIDUAL CIRCUIT IN BOLD TEXT PRIOR TO INSTALLATION OF NEW CIRCUITS. CONTRACTOR TO VERIFY EXISTING METERED DEMAND x 125% PLUS NEW LOAD DOES NOT

EXCEED 80% OF PANEL FEEDER RATING.

SEE NOTE 1

1. CONTRACTOR TO VERIFY EXISTING SCCR RATING. CONTRACTOR TO PROVIDE NEW BREAKERS IN ACCORDANCE WITH THIS RATING.

2. CONTRACTOR TO PROVIDE A 30 DAY METERING OF THE PANEL MAIN AND A 30 DAY METER OF EACH INDIVIDUAL CIRCUIT IN BOLD TEXT PRIOR TO INSTALLATION OF NEW CIRCUITS. CONTRACTOR TO VERIFY EXISTING METERED DEMAND x 125% PLUS NEW LOAD DOES NOT

EXCEED 80% OF PANEL FEEDER RATING.

SEE NOTE 1

1. CONTRACTOR TO VERIFY EXISTING SCCR RATING. CONTRACTOR TO PROVIDE NEW BREAKERS IN ACCORDANCE WITH THIS RATING.

2. CONTRACTOR TO PROVIDE A 30 DAY METERING OF THE PANEL MAIN PRIOR TO INSTALLATION OF NEW CIRCUIT. CONTRACTOR TO VERIFY EXISTING METERED DEMAND x 125% PLUS NEW LOAD DOES NOT EXCEED 80% OF PANEL FEEDER RATING.

1. CONTRACTOR TO VERIFY EXISTING SCCR RATING. CONTRACTOR TO PROVIDE NEW BREAKERS IN ACCORDANCE WITH THIS RATING.

2. CONTRACTOR TO PROVIDE A 30 DAY METERING OF THE PANEL MAIN PRIOR TO INSTALLATION OF NEW CIRCUIT. CONTRACTOR TO VERIFY EXISTING METERED DEMAND x 125% PLUS NEW LOAD DOES NOT EXCEED 80% OF PANEL FEEDER RATING.

1. CONTRACTOR TO VERIFY EXISTING SCCR RATING. CONTRACTOR TO PROVIDE NEW BREAKERS IN ACCORDANCE WITH THIS RATING.

2. CONTRACTOR TO PROVIDE A 30 DAY METERING OF THE PANEL MAIN PRIOR TO INSTALLATION OF NEW CIRCUIT. CONTRACTOR TO VERIFY EXISTING METERED DEMAND x 125% PLUS NEW LOAD DOES NOT EXCEED 80% OF PANEL FEEDER RATING.

SEE NOTE 1

SEE NOTE 1

SEE NOTE 1

NOTES:

TOTAL LOAD: 0.15 0.00 0.00 TOTAL CONNECTED LOAD: 0.4 A

23 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 24

21 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 22

19 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 20

17 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 18

15 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 16

13 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 14

11 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 12

9 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 10

7 EXISTING LOAD 20.0 A 1 0.00 0.00 1 20.0 A EXISTING LOAD 8

5 EXISTING LOAD 20.0 A 1 0.00 0.00 -- -- -- 6

3 EXISTING SPARE (TURNED OFF) 20.0 A 1 0.00 0.00 -- -- -- 4

1 SMOKE DAMPERS SCI REHAB... 20.0 A 1 0.15 0.00 3 30.0 A MAIN 2

CKT CIRCUIT DESCRIPTION TRIP POLE A B C POLE TRIP CIRCUIT DESCRIPTION CKT

CONNECTED LOAD KVA

ENCLOSURE: NEMA 1 WIRES: 4

MOUNTING: SURFACE PHASES: 3

SUPPLY FROM: VOLTAGE: 208Y/120

LOCATION: MAINS RATING: 30A MCB MINIMUM BREAKER SCCR:

PANELBOARD SCHEDULE 2BE

1. PANEL IS FED FROM A 30A FEEDER.

1. CONTRACTOR TO VERIFY EXISTING SCCR RATING. CONTRACTOR TO PROVIDE NEW BREAKERS IN ACCORDANCE WITH THIS RATING.

EL BC115

EMERGENCY EQUIPMENT PANELBOARD SCHEDULE 2BE

SEE NOTE 1

SHEET NAMING CONVENTION

T-001A

2 DIGIT SEQUENTIAL # (01-99)

(FIRST DIGIT INDICATES PLAN

TYPE. SECOND DIGIT INDICATES

FLOOR)

1 DIGIT SHEET TYPE DESIGNATOR

0 - GENERAL

1 - PLANS

2 - ELEVATIONS

3 - SECTIONS

4 - ENLARGED PLANS

5 - DETAILS

6 - SCHEDULES AND DIAGRAMS

7 - VARIES

8 - VARIES

9 - 3D VIEWS (ISO, PERSPECTIVES)

2 DIGIT DESCIPLINE

DESIGNATOR

(IF ONLY ONE LETTER IS

USED, THE SECOND

LETTER IS REPLACED

WITH A DASH "-" AS A

PLACEHOLDER)**

1 DIGIT AREA

DESIGNATOR

(AREA DESIGNATOR

ONLY USED WHEN

PLANS ARE SUBDIVIDED

INTO AREAS.)

TV

COMMUNICATIONS

COAXIAL CATV OUTLET WALL MOUNTED 60" AFF,

UIO

COMMUNICATIONS COMBINATION VOICE/DATA

OUTLET (TWO VOICE & TWO DATA JACKS)

MOUNT 18" AFF, UIO

COMMUNICATIONS VOICE OUTLET MT 48" AFF,

UIO

COMMUNICATIONS DATA OUTLET, MT 18" AFF,

UIO

FLOOR BOX SUITABLE FOR CONCRETE FLOOR

POUR; TWO COMPARTMENTS - POWER AND

TELECOMMUNICATIONS; FLUSH COVER/FLANGE

WITH HINGED ACCESS TO RECEPTACLES AND

JACKS RECESSED BELOW COVER IN FLOOR

BOX. PROVIDE 8" FIRE RATED POKE THRU

ABOVE GROUND FLOOR.

COAXIAL CATV OUTLET CEILING MOUNTED

WALL MOUNTED JUNCTION BOX FOR

VOICE/DATA CONNECTION TO MODULAR

WORKSTATION FURNITURE.

WALL SWITCH, AC TYPE, SPST, MOUNT 48" AFF

WALL MOUNTED SPEAKER VOLUME SWITCH, MT.

48…