Architectural Drawings 1.pdf

PDF 5 MB Posted

Attached to
Z1DA--Project# 614-19-102 - Reno Bldg. 7 Spinal Cord Injury Rehab Area
Solicitation number
36C24920B0003
Issued by

About this file

This document package includes architectural drawings and specifications for renovations to Building 7 at the Memphis VA Medical Center. The project involves renovating areas on the second floor for a spinal cord injury rehabilitation program. Drawings show demolition plans, new floor plans, reflected ceiling plans, partition details, and furniture/equipment plans. Renovations include alterations to walls, floors, ceilings, plumbing fixtures and medical equipment. Specifications provide requirements for construction materials and methods.

View the file

Other files

File Type Posted
36C24920B0003 0007.docx DOCX document
36C24920B0003 0006.docx DOCX document
36C24920B0003 0005.docx DOCX document
36C24920B0003 0004.docx DOCX document
Amendent_SPECS.pdf PDF
Amend Rpt 0001.pdf PDF
Amendment_DRAWINGS.pdf PDF
36C24920B0003 0003.docx DOCX document
RFI Form - Renovate Bldg. 7 SCI Rehab Area.docx DOCX document
Contractor EMR Certification Form 2020.docx DOCX document
36C24920B0003 0002.docx DOCX document
36C24920B0003 0001.docx DOCX document
Drawings 614-19-102.pdf PDF
Electric-Telecom Drawings.pdf PDF
36C24920B0003_1.docx DOCX document
Addendum G-101.pdf PDF
Architectural Drawings 2.pdf PDF
Wage Determination - Shelby County.pdf PDF
Specifications.pdf PDF
Mechanical Drawings.pdf PDF
Fire-Plumbing Drawings.pdf PDF
General Drawings.pdf PDF
Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

ARCHITECTURAL ABBREVIATIONS SYMBOLS:

VIEW TITLES:

PLAN SYMBOLS:

MATERIALS IN SECTION - FILL PATTERNS:

A.F.F.

ACC. DR.

ADAAG

ACCESS.

ADJ.

ACOUST.

A.B.

ACT

ANOD.

A.C.

AL / ALUM.

L

APP.

APPROX.

ARCH.

AT

AT / FP

AVG.

A.W.I.

B.H.M.I.

BM.

BLKG.

BD.

BTM.

BLDG.

CFCI

CH.

CPT.

CLG.

CLG. HT.

CTR.

CL

C. TO C.

C.T.

CLR.

C.O.

CLOS.

CO.

COL.

CONC.

CORR.

COTR

CMU

CONF.

CONST.

CONT.

CONTR.

C.J.

DET.

DIA.

DIM.

DISP.

DR.

DN.

D.S.

DESC.

DWG.

EA.

ELEC.

EL.

E.W.C.

E.R.D.

E.P.

ENGR.

EQUIP.

EQ.

EXIST.

EXP.

E.J. (EXP. JT.)

EXP. TO STRUCT.

EXT.

ETD

FAC.

FDC

FT.

F.E.

F.E.C.

F.H.C.

FIN.

F.P.

F.F.

FLR.

F.D.

FLUOR.

FV.

RECEPTIONIST

REFERENCE

REINFORCEMENT

REQUIRED

REVISIONS / REVISED

RIGHT HAND

RIGHT HAND REVERSE

ROOM

ROUGH OPENING

RUBBER BASE

SEALED CONCRETE

SOLID CORE WOOD

SCHEDULE

SECTION

SEMI-GLOSS PAINT

SERVICE SINK

SHEET METAL

SIMILAR

SOUND TRANSMISSION CLASS

SPECIFICATION

SPRAYED FIRE RESISTIVE

MATERIAL

SQUARE

STAIN

STAINLESS STEEL

STANDARD

STEEL

STORAGE

STRUCTURAL

SUSPENDED

TOILET

TELEPHONE

THICK

THRESHOLD

TEMPERED GLASS

TOP OF

TOP OF BEAM

TOP OF CONCRETE

TOP OF CURB

TOP OF STEEL

TOP OF WALL

TOUCH-UP

TYPICAL

UNDERWRITERS LABORATORIES

UNFINISHED

UNLESS NOTED OTHERWISE

VERTICAL

VESTIBULE

VINYL COMPOSITION TILE

VINYL COVE BASE

WIDTH

WITH

WATER CLOSET

WALL CLEAN OUT

WOOD

WINDOW

WIRE MESH PARTITION

WITHOUT

WATER RESISTANT GYPSUM

BOARD

WEATHERSTRIPPING

WINDOW ROUGH OPENING

YARD

ELEVATION

NUMBER (TYP.)

DWG. NO. WHERE

ELEVATION IS DRAWN

INTERIOR ELEVATION MARK

DWG. NO. WHERE

DETAIL IS DRAWN

CALLOUT HEAD

DETAIL

NUMBER (TYP.)

AREA COVERED

BY DETAIL

DOOR TAGROOM TAG PARTITION TYPE

CONCRETE / GROUT

STEEL

RIGID INSULATION

BATT INSULATION EXPOSED & FINISHED

WOOD TRIM

GYPSUM / PLASTER

PLYWOOD

ABOVE FINISHED FLOOR

ACCESS DOOR / PANEL

AMERICAN WITH DISABILITIES

ACCESSIBILITY GUIDELINES

ACCESSORIES

ADJUST/ ADJUSTABLE

ACOUSTICAL

ANCHOR BOLT

ACOUSTICAL CEILING TILE

ANODIZED

AIR CONDITIONING

ALUMINUM

AND

ANGLE

APPROVED

APPROXIMATE

ARCHITECTURAL

AT

ANTI TERRORISM / FORCE PROTECTION

AVERAGE

ARCHITECTURAL WOODWORK INSTITUTE

BUILDER'S HARDWARE MANUFACTURER'S

ASSOCIATION, INC.

BEAM

BLOCKING

BOARD

BOTTOM

BUILDING

CONTRACTOR FURNISHED CONTRACTOR

INSTALLED

CHANNEL

CARPET

CEILING

CEILING HEIGHT

CENTER

CENTER LINE

CENTER TO CENTER

CERAMIC TILE

CLEAR

CLEANOUT

CLOSET

COMPANY

COLUMN

CONCRETE

CORRIDOR

CONTRACTING OFFICER'S TECHNICAL

REPRESENTATIVE

CONCRETE MASONRY UNIT

CONFERENCE

CONSTRUCTION

CONTINUOUS

CONTRACTOR

CONTROL JOINT

DETAIL

DIAMETER

DIMENSION

DISPENSER

DOOR

DOWN

DOWNSPOUT

DESCRIPTION

DRAWING

EACH

ELECTRICAL OR ELECTRIC

ELEVATION

ELECTRIC WATER COOLER

EMERGENCY ROOF DRAIN

EPOXY PAINT

ENGINEER

EQUIPMENT

EQUAL

EXISTING

EXPANSION / EXPOSED

EXPANSION JOINT

EXPOSED TO STRUCTURE

EXTERIOR

ESTIMATED TRAVEL DISTANCE

FACTORY

FIRE DEPARTMENT CONNECTION

FEET

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FIRE HOSE CABINET

FINISH

FLAT PAINT

FINISHED FLOOR

FLOOR

FLOOR DRAIN

FLUORESCENT

FIELD VERIFY

RECEP.

REF.

REINF.

REQ'D.

REV.

RH

RHR

RM.

R.O.

RB

SC

SCW

SCHED.

SECT.

S.G.P.

SSK

SHT. MET.

SIM.

STC

SPEC(S)

SFRM

SQ.

ST.

S.S.

STD.

STL.

STOR.

STRUCT.

SUSP.

TOIL. / TLT

TEL.

THK.

T'HOLD

TG

T/

TOB

TOC

T/C

TOS

T/W

TU

TYP.

U.L.

UNFIN

U.N.O.

VERT.

VEST.

VCT

VCB

W.

W/ W.C.

WCO

WD.

WDW.

W.M.P.

W/O W.R.G.B.

W.S.

W.R.O.

YD.

KEYNOTE

TAG

CEILING TAG

(TYPE & HEIGHT)

CEILING HGT.

CEILING TYPE

PARTITION TYPE

EQUIPMENT

TAG

GA.

GALV.

G.B.F.

GC

GFCI

GFGI

G.L.

G.P.

GL.

GOVT.

GYP.

GYP. BD. (GWB)

HKS

HR.

HDW.

HGT.

H.

H.P.

H.M.

HORIZ.

H.V.A.C.

IN.

I.D.

INSUL.

INT.

JAN.

J.C.

JT.

JST.

K.P.

LAM.

LDG.

LAV.

L.H.

LHR

LT.

LTG.

LONG.

LVR.

L.P.

MGR.

MANUF.

MATL.

MAX.

MECH.

MTL.

M.W.P.

MIN.

MISC.

N.I.C.

NO. (#)

NTS

NFPA

O.C.

OFCI

OFGI

O.H.

OPNG.

OPP.

O.D.

OSHA

OVHD

PDU

PT

PR.

PNL.

PART.

PLAS.

PL

PLYWD.

LBS. OR #

PSF

PSI

P.M.J.F.

PRE-FAB.

Q.T.

GAGE OR GAUGE

GALVANIZED

GYPSUM BOARD FURRING

GENERAL CONTRACTOR

GOVERNMENT FURNISHED

CONTRACTOR INSTALLED

GOVERNMENT FURNISHED

GOVERNMENT INSTALLED

GIRT LINE

GLOSSY PAINT

GLASS

GOVERNMENT

GYPSUM

GYPSUM BOARD

HOOKS

HANDRAIL

HARDWARE

HEIGHT

HIGH

HIGH POINT

HOLLOW METAL

HORIZONTAL

HEATING VENTILATION & AIR

CONDITIONING

INCH

INSIDE DIAMETER

INSULATION

INTERIOR

JANITOR

JANITOR'S CLOSET

JOINT

JOIST

KICK PLATE

LAMINATE

LANDING

LAVATORY

LEFT HAND

LEFT HAND REVERSE

LIGHT

LIGHTING

LONGITUDINAL

LOUVER

LOW POINT

MANAGER

MANUFACTURER

MATERIAL

MAXIMUM

MECHANICAL

METAL

METAL WALL PANEL

MINIMUM

MISCELLANEOUS

NOT IN CONTRACT

NUMBER

NOT TO SCALE

NATIONAL FIRE PROTECTION

ASSOCIATION

ON CENTER

OWNER FURNISHED

CONTRACTOR INSTALLED

OWNER FURNISHED

GOVERNMENT INSTALLED

OPPOSITE HAND

OPENING

OPPOSITE

OUTSIDE DIAMETER

OCCUPATIONAL SAFETY AND

HEALTH ACT

OVERHEAD

POWER DISTRIBUTION UNIT

PAINT

PAIR

PANEL

PARTITION

PLASTER OR PLASTIC

PLATE

PLYWOOD

POUNDS

POUNDS / SQUARE FOOT

POUNDS / SQUARE INCH

PRE-MOLDED JOINT FILLER

PREFABRICATED

QUARRY TILE

DETAIL IDENTIFIER (MODULE LETTER AND NUMBER)

NORTH ARROWS

FLOOR PLANS, ELEVATIONS OR DETAIL VIEWS TITLE

A-101

SIM

A-101

ROOM

NAME

101 1t 12'-0" 1i

A1

ELEVATIONS, DETAILS & CALLOUTS

SCALE: 1/8" = 1'-0"

REVISION

TAG

N

SECTION NUMBER

DWG. NO. WHERE

SECTION IS DRAWN

WALL SECTION MARK

A1

A-101

SIM

DETAIL NUMBER

DWG. NO. WHERE

SECTION IS DRAWN

DETAIL SECTION MARK

A1

A-101

SIM

1X

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL DRAWING SIZE (30"X42")

B

IM

/1

V A

B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a /1

V

A B ld g

A rc h

V

.r v t

/1

/2

:2

:1

P

M

A-001

GENERAL NOTES,

ABBREVIATIONS & SYMBOLS

RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

4/22/2020 MWD QVL

1. BASED ON THE ASBESTOS SURVEY REPORT THAT WAS PREPARED BY TERRACON CONSULTANTS, INC AND DATED MAY 30, 2019, THERE ARE AREAS OF ASBESTOS-CONTAINING BLACK MASTIC ASSOCIATED WITH NON-ASBESTOS VINYL FLOOR TILE. REFER TO THE ASBESTOS SURVEY REPORT, AD-101 DRAWING & SPECIFICATIONS FOR SPECIFIC REQUIREMENTS AND ASBESTOS RELATED INFORMATION

2. NOTE THAT ALL PERSONNEL HANDLING THE WORK SHALL HAVE CLASS III ASBESTOS TRAINING AS DEFINED IN THE OCCUPATIONAL SAFETY AND HEALTH ADMINISTRATION (OSHA) ASBESTOS STANDARD (29 CFR 1926.1101) AND SHALL COMPLY WITH THE REQUIREMENTS SET FORTH IN THE ON-SITE DOCUMENT ENTITLED "JAMES A. HALEY VETERANS' HOSPITAL, HOSPITAL MEMORANDUM NO. 138-14, ASBESTOS OPERATIONS AND MAINTENANCE PROGRAM" AND DATED JULY, 2007.

GENERAL ASBESTOS CONTAINING MATERIAL NOTES

1. GC TO PROVIDE TEMPORARY CONSTRUCTION /

ENVIRONMENTAL BARRIERS AS REQUIRED BY VA TO FULLY

ENCLOSE ALL AREAS OF CONSTRUCTION. REFER TO EXISTING

VA ASBESTOS REPORT AND SPECIFICATIONS FOR ADDITIONAL

INFORMATION.

2. WHERE TEMPORARY ENVIONMENTAL BARRIERS ARE

INSTALLED, GC TO ENSURE THAT A MINIMUM CLEAR DISTANCE

OF 5'-0" IS PROVIDED ON THE WALKING CIRCULATION SIDE OF

THE BARRIERS SO AS NOT TO IMPEDE THE FLOW OF WALKING

TRAFFIC.

GENERAL CONSTRUCTION /

ENVIRONMENTAL BARRIER NOTES

1. ALL FLOORS OF EXISTING BUILDING WILL BE FULLY OCCUPIED DURING

CONSTRUCTION. CONSTRUCTION MUST BE PHASED AS TO NOT SHUT DOWN

UTILITIES AND INFRASTRUCTURE (I.E. WATER, POWER, DATA, TELEPHONES, ETC.),

AS REQUIRED TO MAINTAIN DAILY, UNINTERRUPTED OPERATIONS.

2. PHASE CONSTRUCTION SO THAT NEW CONSTRUCTION WON'T INTERFERE WITH

EXISTING FUNCTIONS NEARBY. ONLY MAKE FINAL CONNECTIONS WITH EXISTING

BUILDING AFTER COMPLETION OF INSTALLATION.

3. NOTE THAT THERE IS VERY LIMITED PARKING AND MATERIAL STAGING AREAS ON

THE CAMPUS. GC TO COORDINATE WITH VA PROJECT MANAGER FOR REQUIRED

SPACE AVAILABILITY AND ACCESS.

4. GC TO COORDINATE SPECIFIC PHASING REQUIREMENTS WITH VA.

GENERAL PROJECT PHASING &

ACCESS NOTES

GENERAL PROJECT NOTES:

3. HAZARDOUS MATERIALS ABATEMENT PLAN AND ALL REQUIRED ABATEMENT WITHIN THE AREAS OF RENOVATION SHALL BE PERFORMED

BY THE GC AS PART OF THIS CONTRACT PRIOR TO THE START OF SELECTIVE DEMOLITION.

4. IT SHALL BE UNDERSTOOD BY ALL PARTIES THAT THE SCOPE OF SERVICES PROVIDED BY ARCHITECT DOES NOT INCLUDE ANY SERVICES RELATED TO THE DETERMINATION OF MATERIAL OR ITEMS SUSPECTED OF CONTAINING HAZARDOUS MATERIALS. ARCHITECT IS NOT RESPONSIBLE IN ANY WAY FOR SAFETY PRECAUTIONS, INCLUDING MEASURES FOR THE PROTECTION OF THE CONTRACTOR OR SUB CONTRACTORS, NOR FOR THE PROTECT OF GOVERNMENT EMPLOYEES AND THE PUBLIC. SUCH RESPONSIBILITY FOR SAFETY

PRECAUTIONS IS AND SHALL REMAIN THAT OF THE GOVERNMENT AND THE CONTRACTOR.

1. THE DRAWINGS INDICATE THE GENERAL EXTENT OF WORK. THE DRAWINGS ARE NOT

INTENDED TO INDICATE OR DESCRIBE ALL WORK REQUIRED FOR THE FULL

PERFORMANCE AND COMPLETION OF THE REQUIREMENTS OF THE CONTRACT

DOCUMENTS.

2. THE ENUMERATION OF PARTICULAR ITEMS OF WORK IN ONE PORTION OF THE CONTRACT

DOCUMENTS SHALL NOT BE CONSTRUED TO EXCLUDE OTHER ITEMS NECESSARY OR

IMPLIED THEREFROM.

3. THE CONTRACTOR IS RESPONSIBLE FOR THE COORDINATION OF ALL PARTS OF THE

WORK SO THAT NO WORK SHALL BE LEFT IN AN UNFINISHED OR INCOMPLETE CONDITION.

4. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S

PUBLISHED STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS,

ALL REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING

REQUIREMENTS OF THE SOURCES LISTED ABOVE SHALL BE BROUGHT TO THE

CONTRACTING OFFICER'S REPRESENTATIVE ATTENTION PRIOR TO PROCEEDING WITH

THE WORK.

5. THE CONTRACTOR SHALL PROTECT ANY EXISTING, IN-PLACE, AND NEW WORK.

6. ALL WORK NOTED "N.I.C." IS NOT MEANT TO BE PART OF THE CONSTRUCTION SCOPE OF

WORK AGREEMENT.

7. THE CONTRACTOR SHALL PAY FOR AND COORDINATE THE REMOVAL AND LEGAL

DISPOSAL OF MATERIALS AND RUBBISH.

8. ONCE ON SITE, THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND SHALL VERIFY ALL

NEW AND EXISTING CONDITIONS, SHOWN ON THESE DRAWINGS. THE CONTRACTOR

SHALL NOTIFY THE CONTRACTING OFFICER'S REPRESENTATIVE IN WRITING OF ANY

DIFFERING CONDITIONS BEFORE COMMENCEMENT OF WORK.

9. DO NOT SCALE DRAWINGS; DIMENSIONS GOVERN, LARGE SCALE DETAILS GOVERN OVER

SMALL SCALE DETAILS. THE CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER'S

REPRESENTATIVE IN WRITING OF ANY DIFFERING CONDITIONS BEFORE COMMENCEMENT

OF WORK.

10. UNLESS NOTED OTHERWISE, ALL GYPSUM BOARD SURFACES ARE TO RECEIVE ONE

PRIMER COAT AND TWO COATS OF PAINT.

11. DIMENSIONS NOTED AS 'HOLD' SHALL NOT VARY BY MORE THAN 1/8" FROM SIDE TO SIDE

OR FROM FRONT TO BACK, FINISHED SURFACE TO FINISHED SURFACE.

12. NFPA 241, STANDARD FOR SAFEGUARDING CONSTRUCTION, AND ALTERATION

OPERATIONS SHALL BE APPLIED.

13. WALL AND/OR CEILING ASSEMBLIES THAT ARE IDENTIFIED WITH A FIRE RESISTIVE RATING

SHALL BE CONSTRUCTED AS DETAILED HEREIN.

14. DIMENSIONS SHOWN ARE TO FACE OF STUD OR CMU (U.N.O.).

15. PROVIDE EXPANSION AND CONTROL JOINTS IN ALL WORK AS PER PRODUCT

MANUFACTURER'S STANDARDS.

16. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE

CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY

BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.

17. ALL INTERIOR FINISH MATERIALS SHALL COMPLY WITH THE REQUIREMENTS OF ALL

APPLICABLE CODES, ORDINANCES AND REGULATORY AGENCIES.

18. ALL DISSIMILAR METALS SHALL BE ISOLATED FROM EACH OTHER TO AVOID GALVANIC

CORROSION.

19. NOTES APPEAR ON VARIOUS SHEETS FOR DIFFERENT SYSTEMS AND MATERIALS. SHEETS

ARE TO BE REVIEWED AND NOTES ON INDIVIDUAL SHEETS SHALL BE APPLIED TO

RELATED DRAWINGS AND DETAILS.

20. A FINISH INDICATION ON A WALL SHALL MEAN THE ENTIRE LENGTH AND HEIGHT OF WALL

IS TO BE FINISHED OR FIRE-RATED AS INDICATED.

21. WHEN NON-DIMENSIONED PARTITIONS APPEAR IN CONJUNCTION WITH DOOR OPENINGS,

THE DOOR WIDTH AND THE DOOR FRAME DETAILS DETERMINE THE LOCATION OF

ADJACENT WALLS AND FRAMES.

22. DETAILS NOT SHOWN ARE SIMILAR IN CHARACTER TO THOSE DETAILED. WHERE

SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT

THE CONTRACTING OFFICER'S REPRESENTATIVE BEFORE PROCEEDING WITH THE WORK.

23. THE CONTRACTOR SHALL COORDINATE ALL MECHANICAL AND ELECTRICAL FLOOR AND

WALL SLEEVES INCLUDING CONDUITS WITH ALL MECHANICAL, ELECTRICAL, PLUMBING,

FIRE PROTECTION, AND ARCHITECTURAL DRAWINGS.

24. PROVIDE ACCESS PANELS AS REQUIRED BY APPLICABLE CODES AND AS REQUIRED FOR

MECHANICAL EQUIPMENT AND PLUMBING WORK. ALL ACCESS PANELS SHALL BE

CONCEALED AND LOCATIONS SHALL BE REVIEWED WITH THE ARCHITECT PRIOR TO

PROCEEDING.

25. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS

SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE

RESISTIVENESS, FIRE RATING, AND STRUCTURAL INTEGRITY OF THE BUILDING.

26. DO NOT CUT INTO, REMOVE OR ALTER ANY STRUCTURAL MEMBER OR PORTION OF THE

FLOOR SYSTEM UNLESS IT IS SPECIFICALLY NOTED OR SHOWN ON THE DRAWINGS.

27. INTERIOR PARTITION MOVEMENT CONTROL:

A. VERTICAL CONTROL JOINTS FOR ANY WALL LENGTH ARE TO OCCUR AT NOT MORE

THAN 30'-0" O.C. IN THE HORIZONTAL DIRECTION, UNLESS NOTED OTHERWISE.

B. PROVISIONS SHALL BE MADE IN THE DESIGN, FABRICATION, AND INSTALLATION OF

INTERIOR PARTIONS FOR TYPICAL FLOOR DEFLECTIONS OF THE STRUCTURE UNDER

SUPERIMPOSED LOADS AS FOLLOWS:

TYPICAL ROOF/FLOOR MEMBERS: SPAN/360 BUT NOT LESS THAN 1/2”.

28. THE CONTRACTOR SHALL PLAN HIS/HER WORK TO PROVIDE ADEQUATE PROTECTION FOR

PERSONS AND PROPERTY AT ALL TIMES, AND EXECUTE THE WORK IN SUCH A MANNER

TO AVOID ANY HAZARD TO PERSONS AND PROPERTY AS NECESSARY.

29. THE CONTRACTOR SHALL COORDINATE THE PHASING OF THE WORK TO BE PERFORMED

IN OR ABOUT EXISTING FACILITIES, IF APPLICABLE, WITH THE CONTRACTING OFFICER'S

REPRESENTATIVE PRIOR TO START OF SUCH WORK.

30. THE ARCHITECT SHALL NOT BE LIABLE TO THE OWNER OR CONTRACTOR FOR DAMAGE

RESULTING FROM CONFLICTS, INCONSISTENCIES, OR DEVIATIONS IN THE CONTRACT

DOCUMENTS DUE TO UNFORESEEN EXISTING CONDITIONS, ETC. THE CONTRACTOR SHALL

REPORT TO THE ARCHITECT ANY CONFLICTS, INCONSISTENCIES, OR DEVIATIONS

DISCOVERED PRIOR TO COMMENCEMENT OF FABRICATION/CONSTRUCTION.

31. THE CONTRACTOR IS RESPONSIBLE FOR COMPLIANCE WITH REQUIREMENTS OF CONTRACT

DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTNESS OF DIMENSIONS AND

DETAILS, AND FOR COORDINATION OF THE WORK OF ALL TRADES.

32. CONTRACTOR TO FIELD VERIFY AND PROTECT ALL EXISTING CONDUITS AND SYSTEMS WHICH

ARE TO REMAIN UNDISTURBED THROUGHOUT THE CONSTRUCTION PERIOD. IMMEDIATELY

REPORT DAMAGE TO THE ARCHITECT IN WRITING AND REPAIR DAMAGES TO MEET CODES,

MANUFACTURER'S SPECIFICATIONS AND OWNER'S SATISFACTION. NOTIFY THE OWNER AND

ARCHITECT OF ANY DISCREPANCIES.

33. CONTRACTOR TO VERIFY REQUIRED EQUIPMENT (PLUMBING, ETC.) SLAB

OPENINGS/DEPRESSIONS DIMENSIONS/REQUIREMENTS PRIOR TO

FABRICATION/CONSTRUCTION OF SLAB - TYP.

34. THE DOOR TO THE CONSTRUCTION AREA SHALL BE MIN. 36" WIDE WITH A CLOSER AND LEVER

HANDLE LATCHSET, EITHER EXISTING, NEW OR TEMPORARY.

35. REMOVE AND STORE MATERIALS AND EQUIPMENT INDICATED TO BE REUSED OR RELOCATED

TO PREVENT DAMAGE IN A COOL DRY PLACE.

36. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING AND ACQUIRING ALL

REQUIRED CITY AND STATE PERMITS.

37. CONTRACTOR RESPONSIBLE FOR COORDINATING INTERIOR FINISHES LISTED IN PLANS,

SCHEDULES, NOTES, AND ELEVATIONS. NOTIFY ARCHITECTS OF ANY CONFLICTS,

INCONSISTENCIES, OR DEVIATIONS IN WRITING PRIOR TO CONSTRUCTION.

38. THE GENERAL CONTRACTOR AND SUBCONTRACTOR TO COORDINATE FINISH HARDWARE AND

KEYING WITH OWNER. CONTRACTOR TO PROVIDE A COMPLETE AND OPERATIONAL SYSTEM;

APPROVED BY OWNER.

39. CONSTRUCTION LIMITS - ALL CONTRACTOR VEHICLES AND TRAFFIC SHALL REMAIN WITHIN

THE DESIGNATED CONSTRUCTION AREAS, STAGING AREAS OR HAUL ROUTES.

40. ACCESS TO THE SITE - CONTRACTOR'S ACCESS TO THE SITE SHALL BE AS DIRECTED BY THE

OWNER. THE CONTRACTOR SHALL NOT PERMIT ANY UNAUTHORIZED CONSTRUCTION

PERSONNEL OR TRAFFIC ON THE SITE. THE CONTRACTOR IS RESPONSIBLE FOR THE

IMMEDIATE CLEAN-UP OF ANY DEBRIS DEPOSITED ALONG THE ACCESS ROAD AS A RESULT

OF HIS/HER CONSTRUCTION TRAFFIC. DIRECTIONAL SIGNING AT THE ACCESS GATE AND

ALONG THE DELIVERY ROUTE TO THE STORAGE AREA OR WORK SITE SHALL BE AS DIRECTED

BY THE OWNER.

41. MATERIALS DELIVERY TO THE SITE - ALL CONTRACTOR'S MATERIAL ORDERS FOR DELIVERY

TO THE SITE WILL USE THE ACCESS POINT AT THE CONTRACTOR'S STORAGE SITE AS

APPROVED BY OWNER. THE CONTRACTOR SHALL PROVIDE ADEQUATE ROADWAY SIGNS TO

DIRECT DELIVERIES.

42. CONSTRUCTION AREA LIMITS - THE LIMITS OF CONSTRUCTION , MATERIAL STORAGE AREAS, EQUIPMENT STORAGE AREA, PARKING AREA AND OTHER AREAS DEFINED AS REQUIRED FOR

THE CONTRACTOR'S EXCLUSIVE USE DURING CONSTRUCTION SHALL BE MARKED BY THE

CONTRACTOR AND APPROVED BY THE OWNER. THE CONTRACTOR SHALL ERECT AND

MAINTAIN AROUND THE PERIMETER OF THESE AREAS SUITABLE FENCING, SIGNAGE AND

WARNING DEVICES VISIBLE FOR BOTH DAY/NIGHT USE TO DELINEATE THE PERIMETER OF ALL

SUCH AREAS.

43. SUBMIT LIGHT GAUGE METAL FRAMING SHOP DRAWINGS SIGNED AND SEALED BY A

PROFESSIONAL ENGINEER LICENSED FOR APPROVAL.

44. PREPARE, APPLY, AND/OR INSTALL MATERIALS TO MEET ALL MANUFACTURER'S WARRANTIES

AND SPECIFICATIONS.

45. THE AVAILABILITY OF ALL MATERIALS DESIGNATED ON PLANS SHALL BE VERIFIED BY

CONTRACTORS AND SUBCONTRACTORS PRIOR TO ESTIMATE SUBMITTALS. CONTRACTOR TO

NOTIFY ARCHITECT IF MATCHING MATERIALS ARE NOT AVAILABLE. ANY SUBSTITUTIONS TO BE

REVIEWED AND APPROVED.

46. ESTABLISH PROCEDURES AND EXECUTE OPERATIONS TO PROVIDE CONTINUOUS SECURITY.

PROVIDE TEMPORARY PROTECTION FROM OPENINGS AND AT OTHER LOCATIONS AS MAY BE

APPROPRIATE DURING CONSTRUCTION. DENY ENTRANCE OF UNAUTHORIZED PERSONS INTO

WORK AREA.

47. IT IS THE CONTRACTOR'S SOLE RESPONSIBILITY TO DETERMINE DEMOLITION PROCEDURE

AND SEQUENCE TO INSURE THE SAFETY OF THE BUILDING AND ITS COMPONENT PARTS

DURING DEMOLITION. THIS INCLUDES, BUT IS NOT LIMITED TO, THE ADDITION OF WHATEVER

TEMPORARY BRACING, GUYS OR TIE-DOWNS MAY BE NECESSARY. SUCH MATERIAL SHALL BE

REMOVED AND SHALL REMAIN THE PROPERTY OF THE CONTRACTOR AFTER COMPLETION OF

THE PROJECT.

48. ALL RFI's, PROPOSED CHANGES, OR PROPOSED VALUE ENGINEERING ITEMS MUST HAVE A COST SUBMITTED AND ITS IMPACT (i.e. NO COST, ADDITIONAL COST, CREDIT, CONSTRUCTION

SCHEDULE IMPACT,ETC.) PRIOR TO ARCHITECT'S APPROVAL. IT SHALL BE UNDERSTOOD

OMISSION OF THESE ITEMS REPRESENTS THERE IS NO COST OR SCHEDULE INCREASE

ASSOCIATED.

49. ALL CUTTING AND PATCHING SHALL BE PERFORMED BY THE GENERAL CONTRACTOR.

GENERAL CONTRACTOR SHALL INCLUDE COST OF ALL REQUIRED CUTTING AND PATCHING

FOR ALL TRADES IN THEIR ESTIMATE.

50. THE CONTRACTOR SHALL PERFORM ALL WORK IN ACCORDANCE WITH ALL APPLICABLE

CODES, ORDINANCES AND REGULATORY AGENCIES AND SHALL OBTAIN NECESSARY

BUILDING AND FIRE PERMITS FROM ALL AUTHORITIES HAVING JURISDICTION.

51. SAFETY AND SECURITY - THE CONTRACTOR SHALL CONDUCT HIS/HER ACTIVITIES IN A SAFE

AND SECURE MANNER. CONTRACTOR TO COMPLY WITH ALL OSHA STANDARDS AND

REGULATIONS.

52. FLOAT OUT AND/OR GRIND FLOOR IRREGULARITIES WHERE OCCURRING AS NECESSARY FOR

SMOOTH LEVEL FLOOR IN CONDITION TO RECEIVE SCHEDULED FLOOR MATERIALS. COMPLY

WITH ALL MATERIAL MANUFACTURES RECOMMENDATIONS (INCLUDING SLAB MOISTURE

REQUIREMENT), ALL CODES (FED, STATE AND LOCAL, ETC) AND SPECS AND DRAWINGS.

53. ALL WOOD BLOCKING AND CONCEALED LUMBER TO BE FIRE RETARDANT TREATED. G.C.

SHALL COORDINATE ALL REQUIRED BLOCKING WITH THE OWNER & OWNER'S VENDOR(S)

FOR ALL WALL MOUNTED ACCESSORIES & MISC WALL MOUNTED OR RECESSED ITEMS.

54. PROVIDE DENS-SHIELD (OR EQUAL TILE BACKER BOARD AS APPROVED BY ARCHITECT) AT

ALL TILE & TILE WET WALL LOCATIONS U.O.N.

55. CONTRACTOR TO FRAME FOR RIGID CONDITION AT ALL FRAMING CONDITIONS. TO

INCLUDE BUT NOT LIMITED TO DOORS, WINDOWS, WALLS, ROOF, ETC.

56. CONTRACTOR TO PROVIDE ALL ENGINEERING AND SHOP DRAWINGS OF ALL GLAZED

WINDOW SYSTEMS (INCLUDING ALL ANCHORAGE CONDITIONS - SIGNED AND SEALED) .

FIELD VERIFY ALL DIMENSIONS PRIOR TO FABRICATION AND CONSTRUCTION. PROVIDE

WATERPROOF CONDITION AT ALL GLAZING SYSTEMS.

57. PROVIDE OPENINGS IN NEW AND EXISTING WALLS, FLOORS, AND ROOF FOR ALL

MECHANICAL, ELECTRICAL, PLUMBING, ETC. PROVIDE FLASHING, COUNTER-FLASHING,

SEALANTS, SMOKE BARRIERS / DAMPERS, AND FIRE-SAFING REQUIRED TO MEET

MANUFACTURER'S WARRANTIES AND SPECIFICATIONS, FED, STATE AND LOCAL CODES.

COORDINATE WITH M.E.P. DRAWINGS. COORDINATE WITH ALL TRADES. NOTIFY

ARCHITECT IN WRITING OF ALL DISCREPANCIES. PROVIDE REVISIONS PRIOR TO

CONSTRUCTION.

58. ALL UNDERGROUND, UTILITY LINES AND CABLES TO REMAIN SHALL BE PROTECTED.

NOTIFY ARCHITECT IN WRITING OF ANY DAMAGE TO EXISTING ITEMS TO REMAIN.

59. DIMENSIONS ARE TO FACE OF EXISTING WALL/CONSTRUCTION, STRUCTURAL COLUMN

CENTERLINES, OR FACE OF STUD OR CMU UNLESS OTHERWISE NOTED.

60. PROVIDE BLOCKING AND OR SHIMS NECESSARY TO INSTALL, BUT NOT LIMITED TO, DOORS, WINDOWS, FIXTURES, MILLWORK, AND EQUIPMENT, WHICH WILL MEET ALL

MANUFACTURER'S WARRANTIES AND SPECIFICATIONS. BLOCKING TO MEET ALL

APPLICABLE FEDERAL, STATE, AND LOCAL CODES.

61. ALL EXPOSED INTERIOR AND EXTERIOR BUILDING FEATURES SHALL BE PAINTED (UNLESS

OTHERWISE SPECIFICALLY NOTED) IF NOT SUPPLIED AS A FINISH PRODUCT PER OWNER

OR SPECIFIED BY ARCHITECT, COORDINATE AND PROVIDE FINISH. PAINTING EXCLUDES

GALVANIZED AND/OR PRE-FINISHED FACTORY ITEMS.

62. STRUCTURAL MEMBERS: ANY STRUCTURAL MEMBERS ACCIDENTALLY OR INTENTIONALLY

CUT WITHOUT PROPER AUTHORIZATION SHALL BE RESTORED TO ORIGINAL INTEGRITY

AND CONDITION TO THE SATISFACTION OF THE ARCHITECT AND THE OWNER.

63. ALL FIELD ADJUSTMENTS SHOULD COMPLY WITH THE INTENT OF THE CONTRACT

DOCUMENTS AND ALL APPLICABLE CODES. NOTHING SHALL RELIEVE THE CONTRACTOR

FROM COMPLIANCE WITH REQUIREMENTS OF THE CONTRACT DOCUMENTS AND ALL

APPLICABLE CODES. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTNESS OF

DIMENSIONS AND DETAILS, QUANTITIES FOR COORDINATION OF ALL TRADES AND

CONDITIONS (CLEARANCES, FIXTURES, EQUIPMENT, ETC) AND ANY ADDITIONAL COSTS

INCURRED AS A RESULT OF CONTRACTOR REQUESTED FIELD ADJUSTMENTS.

64. ALL WORK SHALL CONFORM TO APPLICABLE INDUSTRY AND MANUFACTURER'S PUBLISHED

STANDARDS FOR QUALITY OF MATERIALS AND WORKMANSHIP, AS WELL AS, ALL

REQUIREMENTS IN THESE DRAWINGS AND SPECIFICATIONS. ANY CONFLICTING

REQUIREMENTS SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION IN WRITING PRIOR

TO COMMENCEMENT OF WORK.

65. ALL PIPE DUCTS AND BUS DUCTS THAT PENETRATE FLOOR SLABS OR WALL PARTITIONS

SHALL BE INSTALLED IN A MANNER THAT WILL PRESERVE THE MOISTURE RESISTIVENESS,

FIRE RATING, AND STRUCTURAL INTEGRITY OF THE BUILDING.

66. ARCHITECT'S REVIEW OF SHOP DRAWING'S IS FOR GENERAL COMPLIANCE WITH

CONTRACT DOCUMENTS ONLY. SHOP DRAWINGS MARKED "NO EXCEPTIONS TAKEN" OR

"COMPLY WITH MARKINGS" AS WELL AS ANY ADDITIONAL MARKINGS OR NOTES DO NOT

RELIEVE THE CONTRACTOR FROM COMPLIANCE WITH THE REQUIREMENTS OF THE

CONTRACT DOCUMENTS. THE CONTRACTOR IS RESPONSIBLE FOR CORRECTNESS OF

DIMENSIONS AND DETAILS, AND FOR COORDINATION OF THE WORK OF ALL TRADES.

67. THE GC SHALL INSTALL AND MAINTAIN TEMPORARY SIGNAGE FOR ALL PHASES OF

CONSTRUCTION TO INDICATE "WARNING - CONSTRUCTION AREA - DO NOT ENTER" ON THE

DOOR TO THE CONSTRUCTION AREA.

68. PROVIDE FIRE AND SMOKE JOINT SYSTEMS , FIRE SAFEING, FIRE AND SMOKE CLOSURES, ETC. TO MAINTAIN FIRE AND SMOKE RATINGS AT ALL FIRE AND SMOKE WALL LOCATIONS, AND WHERE ALL SHAFTS AND WALLS INTERSECT FLOOR AND ROOF DECKS. COMPLY WITH

IBC 715

69. THE FOLLOWING PLANS ARE INTENDED TO PROVIDE THE CONTRACTOR WITH A GENERAL

KNOWLEDGE OF THE EXISTING CONDITIONS WITHIN THE PROJECT AREA. EXISTING

EQUIPMENT, STRUCTURE, DUCTWORK, ETC. LOCATED ON DRAWING WERE DERIVED FROM

LIMITED FIELD OBSERVATIONS AND THE EXISTING AS-BUILTS WHICH MAY NOT BE UP TO

DATE. THIS DRAWING MAY NOT BE ALL INCLUSIVE OF SERVICES AND CONDITIONS THAT

EXIST IN THE PROJECT AREA. CONTRACTOR SHALL VERIFY ALL SERVICES, CONDITIONS

AND LOCATIONS PRIOR TO ANY DEMOLITION WORK COMMENCING. ANY DEVIATIONS

IMPACTING WORK SHOWN ON THESE DOCUMENTS SHALL BE REPORTED TO THE

ARCHITECT AND ENGINEER PRIOR TO BEGINNING DEMOLITION. BEGINNING OF DEMOLITION

SHALL SIGNIFY CONTRACTOR'S ACCEPTANCE OF EXISTING CONDITIONS AND THE COST OF

NECESSARY CONSTRUCTION REVISIONS DUE TO CONFLICTS AND/OR UNFORESEEN

CONDITIONS. THE CONTRACTOR IS RESPONSIBLE FOR ALL REQUIRED DEMOLITION

WHETHER SHOWN ON THE PLANS OR NOT.

70. THE CONTRACTOR SHOULD OBTAIN A HOT WORK PERMIT PRIOR TO BEGINNING ANY

WELDING, CUTTING, BRAZING, GRINDING OR OTHER ACTIVITY THAT GENERATES SPARKS

CAPABLE OF CAUSING COMBUSTION. SEE NFPA 51B AND APPENDIX A FOR ADDITIONAL

INFORMATION. PROVIDE A FIRE WATCH AND/OR A GUARD WATCH AS REQUIRED BY NFPA

601 DURING THE PROCESS OF CUTTING, WELDING, BRAZING, GRINDING OR OTHER

ACTIVITY THAT GENERATES SPARKS CAPABLE OF CAUSING COMBUSTION , ETC.

71. CONTACT ARCHITECT TO CLARIFY ANY DRAWING DISCREPANCY AND/OR CONFLICTS OF

DIFFERENT BIDDING ELEMENTS/ COMPONENTS. FOR THE PURPOSES OF PRICING AND

BIDDING ASSUME THE MORE COSTLY OPTION .

CORRIDOR

C2-30

ELEVATOR ELEVATOR ELEVATOR

STAIR

NO 4

STAIR

NO 5

COMM

2C100

EC

2C101

LACK

2C103

STORAGE

2C106B

WHEEL CHAIR STORAGE

2C106A

STORAGE

2C106

PHYSICAL THERAPY

2C110

TOILET

2C-08

CORRIDOR

C2-27

STORAGE

2C110A

OFFICE

2C110B

COMM

2C117

EC

2C118

CORRIDOR

C2-29CORRIDOR

C2-28

STORAGE

2C121

R.T. CLINIC

2C120DRIVER CLINIC

2C115

MEN TOILET

2C113

WOMEN TOILET

2C114

TOILET

2C116 JAN. CLOSET

2C119

STORAGE /

BREAK ROOM

2C112A

MED REHAB

2C112

STORAGE

2C111B

O.T. CLINIC

2C111

2C111C

OFFIC

2C111A

PRIVATE TREATMENT

2C109

K.T. CLINIC

2C107

OFFICE

2C107A TOILET

2C104

JAN. CLOSET

2C102

OPEN COURTYARD

OPEN COURTYARD

AREA OF WORK

2ND FLOOR

1. CONTRACTOR TO VERIFY ALL EXISTING CONDITIONS AND DIMENSIONS PRIOR TO STARTING WORK.

2. DEMOLITION WORK SHALL BE AS REQUIRED TO ACHIEVE CLEAN, SMOOTH, AND PLUMB NEW WORK. FOR EXAMPLE IT IS REQUIRED THAT ITEMS SUCH AS EXISTING SCREWS ON WALLS TO BE REMOVED IN ORDER TO INSTALL NEW DRYWALL OR FINISHES. ANOTHER EXAMPLE IS THAT IF A NEW THERMOSTAT IS SPECIFIED, THE EXISTING THERMOSTAT IF NOT SCHEDULED TO BE REUSED WILL HAVE TO BE REMOVED BY THE CONTRACTOR WHETHER IT IS SHOWN

ON THE DRAWINGS OR NOT.

3. WHEN PARTIAL DEMOLITION IS MADE TO EXISTING WALL OR FLOOR, A SAW CUT THRU EXISTING SURFACE IS REQUIRED TO PREVENT UNNECESSARY

DAMAGE TO ADJACENT AREAS.

4. CONTRACTOR SHALL INVESTIGATE EXISTING CONDITIONS PRIOR TO STARTING WORK TO DETERMINE THE LOCATION OF LOAD BEARING WALLS AND STRUCTURAL COLUMNS. WHEN SUCH ITEMS ARE SCHEDULED TO BE DEMOLISHED, SHORE UP SYSTEM PROPERLY PRIOR TO REMOVING THEM. WHEN IN

DOUBT, CONTACT ARCHITECT PRIOR TO REMOVING ANY ITEMS IN QUESTION.

5. G.C. TO REMOVE ALL WALL MOUNTED ITEMS ON WALLS SCHEDULED TO RECEIVE NEW FINISHES, TYPICAL. ALL THESE ITEMS TO BE REINSTALLED BY G.C.

UNLESS DIRECTED OTHERWISE BY VA OR UNLESS SCHEDULED TO BE RELOCATED ELSEWHERE IN CONTRACT DOCUMENTS.

6. CONTRACTOR SHALL COORDINATE WITH VA'S PROJECT MANAGER FOR WORK TIME SCHEDULE TO NOT INTERFERE WITH EXISTING OWNER OPERATIONS.

7. ALL WORK REQUIRING THE USE OF TOOLS THAT WILL PRODUCE AN OBJECTIONABLE AMOUNT OF NOISE, FUMES, OR DUST BEYOND A FAIR AND REASONABLE AMOUNT AS REQUIRED FOR DEMOLITION OR NEW CONSTRUCTION SHALL BE CONDUCTED DURING THE HOURS OF 6:00PM UNTIL 8:00AM AND ON WEEKENDS. NO CONTRACT INCREASE ADJUSTMENT IN TIME OR MONEY SHALL BE MADE IF CONTRACTOR IS STOPPED DUE TO WORK BEING CONDUCTED BY CONTRACTOR DUE TO OBJECTIONABLE NOISE, FUMES, OR DUST. SCHEDULE ACCESS AND NEEDED SECURITY ESCORTS IN ADVANCE OF

NEEDED ACCESS AFTER NORMAL WORK HOURS.

8. ALL WORK WILL BE SUBJECT TO RE-SCHEDULING IF SO REQUESTED BY THE OWNER AND MAY OCCUR AT THE OWNER'S DISCRETION. CONTRACTOR SHALL SCHEDULE AND COORDINATE ALL CONSTRUCTION ACTIVITIES, INCLUDING BUILDING ACCESS, TRASH DISPOSAL AND SECURITY CLEARANCE FOR

PERSONNEL WITH VA PROJECT MANAGER.

9. GC TO PROVIDE DUST AND NOISE PROOF CONSTRUCTION BARRIER AS REQUIRED TO SEPARATE CONSTRUCTION AREAS FROM ADJACENT OFFICE

AREAS. MAINTAIN 2 MEANS OF EGRESS OUT OF CONSTRUCTION AREA AT ALL TIMES.

10. ANY REMAINING FURNITURE/CONTAINS IN THE AREA OF RENOVATION TO BE DISPOSED OF BY GC & COORDINATE WITH VA.

GENERAL DEMOLITION NOTES:

DEMOLITION PLAN LEGEND

EXISTING WALLS / PARTITIONS TO REMAIN

EXISTING STUD WALLS / PARTITIONS TO BE

DEMOLISHED

EXISTING DOOR & DOOR FRAME

ACCESSORIES TO REMAIN

EXISTING DOOR, FRAME AND ACCESSORIES

TO BE DEMOLISHED

AREA OF NO WORK

AREA OF ASBESTOS-CONTAINING BLACK

MASTIC ASSOCIATED WITH NON-

ASBESTOS VINYL FLOOR TILE. REFER TO

ASBESTOS SURVEY REPORT THAT WAS

PREPARED BY TERRACON CONSULTANTS,

INC AND DATED MAY 30, 2019

EXISTING EXTERIOR WINDOW TO REMAIN

CORRIDOR

C2-30

ELEVATOR ELEVATOR ELEVATOR

STAIR

NO 4

STAIR

NO 5

COMM

2C100

EC

2C101

LACK

2C103

STORAGE

2C106B

WHEEL CHAIR STORAGE

2C106A

STORAGE

2C106

PHYSICAL THERAPY

2C110

TOILET

2C-08

CORRIDOR

C2-27

STORAGE

2C110A

OFFICE

2C110B

COMM

2C117

EC

2C118

CORRIDOR

C2-29

CORRIDOR

C2-28

STORAGE

2C121

R.T. CLINIC

2C120DRIVER CLINIC

2C115

MEN TOILET

2C113

WOMEN TOILET

2C114

TOILET

2C116

JAN.

CLOSET

2C119

STORAGE /

BREAK ROOM

2C112A

MED REHAB

2C112

STORAGE

2C111B

O.T. CLINIC

2C111

2C111C

OFFIC

2C111A

PRIVATE TREATMENT

2C109

K.T. CLINIC

2C107

OFFICE

2C107A TOILET

2C104

JAN. CLOSET

2C102

OPEN COURTYARD

OPEN COURTYARDP-8

P-1

P-2

P-3

P-4

P-5

P-6

P-7

P-9

P-10

P-18

P-11 P-12

P-13

P-14

P-15

P-16

P-17

EXISTING RATED WALL LEGEND

1-HR RATED FIRE BARRIER

2-HR RATED FIRE BARRIER

1-HR FIRE RATED SMOKE BARRIER

SMOKE PARTITION

EXISTING FIRE RATED PARTITIONS/BARRIERS SHOWN

ARE BASED ON THE VA PROVIDED DRAWINGS THAT WAS

PREPARED BY FIRE PROTECTION & CODE CONSULTANT,

LLC. AND DATED OCTOBER 30, 2018. GC TO FIELD VERIFY.

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL DRAWING SIZE (30"X42")

B

IM

/1

V A

B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a /1

V

A B ld g

A rc h

V

.r v t

/1

/2

:2

:5

P

M

AD101

PARTIAL 2ND LEVEL - DEMOLITION

PLAN

RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

4/22/2020 MWD QVL

SCALE: 1/8" = 1'-0"F1

PARTIAL 2ND LEVEL - DEMOLITION PLAN

SCALE: = 1'-0"

0 8 168

1/8"

KEYPLAN

N

KEYNOTES - DEMOLITION PLAN

NO. DESCRIPTION

12 CAREFULLY REMOVE, SALVAGE FOR REUSE EXISTING CEILING

MOUNTED PATIENT LIFTS AND RAILS, AND EXISTING FLOOR

MOUNTED CLINIC EQUIPMENT. COORDINATE WITH VA FOR STORAGE.

REINSTALL EXISTING PATIENT LIFTS & CEILING RAILS. COORDINATE

WITH VA USERS IF CEILING RAILS NEED TO MODIFY LENGTH FOR

FULLY FUNCTIONING. NOTE THAT THIS WILL NOT BE A SEPARATE

PURCHASE SO GC TO BE RESPONSIBLE FOR REMOVING, STORING,

REINSTALLING AND ADDING LENGTH/ MODIFYING AS REQUIRED.

PROVIDE STRUCTURAL CONNECTIONS AS REQUIRED FOR LOAD

CAPCITY OF EACH LIFT. PROVIDE SIGNED AND SEALED STRUCTURAL

SHOP DRAWINGS FOR APPROVAL. REFER TO A-171 FOR FURNITURE /

EQUIPMENT PLAN AND COORDINATE WITH VA FOR LOCATIONS. SEE

ELECTRICAL FOR ADDITIONAL WORK.

13 EXISTING WALL MOUNTED FIRE EXTINGUISHER TO REMAIN.

14 DEMOLISH EXISTING CERAMIC WALL TILES.

15 DEMOLISH EXISTING WALL MOUNTED SHELF.

16 EXISTING STRUCTURAL BEAM ABOVE TO REMAIN.

17 REMOVE, SALVAGE FOR REUSE EXISTING WHEEL CHAIRS,

FURNITURE, APPLIANCES, SHELVING, WALL MOUNTED ITEMS &

EQUIPMENT. COORDINATE WITH VA FOR STORAGE.

18 EXISTING EXTERIOR WINDOW TO REMAIN.

19 REMOVE, SALVAGE FOR REUSE EXISTING PORTABLE MEDICAL GAS

RACKS.

20 DEMOLISH GWB CEILING & CEILING FIXTURES TO RECEIVE NEW

CEILING SYSTEMS AS SHEDULED.

21 EXISTING 3'H POST TO REMAIN. DEMOLISH DOOR OPENER AND

PROVIDE NEW DOOR OPENER AT THE SAME LOCATION.

22 DEMOLISH EXISTING DOUBLE DOOR ASSEMBLY TO RECEIVE NEW

DOORS, DOOR HARDWARE, AND DOOR FRAME ASSEMBLY AS

SCHEDULED.

23 DEMOLISH THIS EXISTING WALL. RECESS NEW WALL TO RECEIVE

NEW DOUBLE DOORS. REFER TO NEW FLOOR PLAN FOR MORE

INFORMATION.

KEYNOTES - DEMOLITION PLAN

NO. DESCRIPTION

1 DEMOLISH EXISTING PLUMBING FIXTURES. CAP ALL PIPES WHERE

NOT USED FOR NEW WORK.

2 EXISTING SS COUNTER TOP AND PLUMBING FIXTURE TO REMAIN.

3 DEMOLISH EXISTING FLOOR FINISH, EXISTING BASE, EXISTING

HANDRAILS AND CRASHRAILS (AT CORRIDOR). PREP SUB FLOOR AND

EXISTING REMAIN WALL TO RECEIVE NEW FLOOR FINISH & NEW

BASE AS SCHEDULED.

4 DEMOLISH EXISTING FLOOR TILE ASSEMBLY & WALL TILE BASE TO

STRUCTURAL SLAB. PREP SUB FLOOR TO RECEIVE NEW FLOORING

FINISH & NEW BASES AS SCHEDULED.

5 DEMOLISH ALL CEILING TILES, CEILING GRIDS & CEILING FIXTURES

TO RECEIVE NEW CEILING SYSTEMS AS SHEDULED.

6 EXISTING DOOR, DOOR HARDWARE, & DOOR FRAME TO REMAIN.

REPAIR & STAIN DOOR AS SCHEDULED. REPLACE DOOR IF IT IS

DAMAGED. PAINT EXISTING DOOR FRAME AS SCHEDULED.

7 DEMOLISH EXISTING EXTERIOR DOUBLE DOOR ASSEMBLY. PREP

OPENING TO RECEIVE NEW DOORS, DOOR HARDWARE, AND DOOR

FRAME ASSEMBLY AS SCHEDULED.

8 EXISTING CONCRETE SHEAR WALL TO REMAIN. PATCH AND REPAIR

EXISTING GWB AS REQUIRED.

9 EXISTING DRINKING FOUNTAIN TO REMAIN.

10 DEMOLISH EXISTING WOOD WALL PANEL. SALVAGE AND RETURN TO

VA FOR REUSE. PATCH AND REPAIR EXISTING GWB AS REQUIRED.

PROVIDE NEW GWB IF MISSING TO RECEIVE NEW FINISHES AS

SCHEDULED.

11 EXISTING FIRE EXTINGUISHER CABINET TO REMAIN.

SCALE: 1/8" = 1'-0"F4

PARTIAL 2ND LEVEL - ASBESTOS CONTAINING PLAN & PHOTO PLAN

P-1

P-2 P-3 P-4 P-5

P-6 P-7 P-8 P-9 P-10

P-18

17 15

P-11 P-12 P-13 P-14 P-15

P-16 P-17

10 11121714 3 5 1 17

1417 1217 18

12 17 17 17 17 17 16

17 17 19

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL DRAWING SIZE (30"X42")

B

IM

/1

V A

B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a /1

V

A B ld g

A rc h

V

.r v t

/1

/2

:2

:1

P

M

AD102

EXISTING CONDITION PHOTOS RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

4/22/2020 MWD QVL

KEYNOTES - DEMOLITION

NO. DESCRIPTION

13 EXISTING WALL MOUNTED FIRE EXTINGUISHER TO REMAIN.

14 DEMOLISH EXISTING CERAMIC WALL TILES.

15 DEMOLISH EXISTING WALL MOUNTED SHELF.

16 EXISTING STRUCTURAL BEAM ABOVE TO REMAIN.

17 REMOVE, SALVAGE FOR REUSE EXISTING WHEEL CHAIRS, FURNITURE, APPLIANCES,

SHELVING, WALL MOUNTED ITEMS & EQUIPMENT. COORDINATE WITH VA FOR STORAGE.

18 EXISTING EXTERIOR WINDOW TO REMAIN.

19 REMOVE, SALVAGE FOR REUSE EXISTING PORTABLE MEDICAL GAS RACKS.

KEYNOTES - DEMOLITION

NO. DESCRIPTION

1 DEMOLISH EXISTING PLUMBING FIXTURES. CAP ALL PIPES WHERE NOT USED FOR NEW

WORK.

3 DEMOLISH EXISTING FLOOR FINISH, EXISTING BASE, EXISTING HANDRAILS AND

CRASHRAILS (AT CORRIDOR). PREP SUB FLOOR AND EXISTING REMAIN WALL TO

RECEIVE NEW FLOOR FINISH & NEW BASE AS SCHEDULED.

5 DEMOLISH ALL CEILING TILES, CEILING GRIDS & CEILING FIXTURES TO RECEIVE NEW

CEILING SYSTEMS AS SHEDULED.

10 DEMOLISH EXISTING WOOD WALL PANEL. SALVAGE AND RETURN TO VA FOR REUSE.

PATCH AND REPAIR EXISTING GWB AS REQUIRED. PROVIDE NEW GWB IF MISSING TO

RECEIVE NEW FINISHES AS SCHEDULED.

11 EXISTING FIRE EXTINGUISHER CABINET TO REMAIN.

12 CAREFULLY REMOVE, SALVAGE FOR REUSE EXISTING CEILING MOUNTED PATIENT LIFTS

AND RAILS, AND EXISTING FLOOR MOUNTED CLINIC EQUIPMENT. COORDINATE WITH VA

FOR STORAGE. REINSTALL EXISTING PATIENT LIFTS & CEILING RAILS. COORDINATE

WITH VA USERS IF CEILING RAILS NEED TO MODIFY LENGTH FOR FULLY FUNCTIONING.

NOTE THAT THIS WILL NOT BE A SEPARATE PURCHASE SO GC TO BE RESPONSIBLE FOR

REMOVING, STORING, REINSTALLING AND ADDING LENGTH/ MODIFYING AS REQUIRED.

PROVIDE STRUCTURAL CONNECTIONS AS REQUIRED FOR LOAD CAPCITY OF EACH LIFT.

PROVIDE SIGNED AND SEALED STRUCTURAL SHOP DRAWINGS FOR APPROVAL. REFER

TO A-171 FOR FURNITURE / EQUIPMENT PLAN AND COORDINATE WITH VA FOR

LOCATIONS. SEE ELECTRICAL FOR ADDITIONAL WORK.

AREA OF WORK

2ND FLOOR

ELEVATOR ELEVATOR ELEVATOR

STAIR

NO 4

STAIR

NO 5

ELEVATOR ELEVATOR ELEVATOR

STAIR

NO 4

STAIR

NO 5

A-402B1

COMM

2C100

EC

2C101

COMM

2C100

EC

2C101

CORRIDOR

C2-30

CORRIDOR

C2-30

PRIVATE

TREATMENT

2C104

WAITING

2C102

CHECK-IN

DESK

2C103

STORAGE

2C105

DRIVER

THERAPY

2C106

MULTI-PURPOSE

ROOM

2C107

MEN

(PATIENT)

2C108

WOMEN

(PATIENT)

2C109

EQUIP.

STORAGE

2C110

PHYSICAL

THERAPY

(PT)

2C111

KINESIO-THERAPY

(KT)

2C112

OCCUPATIONAL

THERAPY

(OT)

2C113

BREAKROOM

2C114

WOMEN

(STAFF)

2C115

MEN

(STAFF)

2C116

COMM

2C117

EL

2C118

JAN

2C119

RECREATIONAL

THERAPY

2C120

STORAGE

2C121

CORRIDOR

C2-27

CORRIDOR

C2-28

A-402

E1

A-402 E6

A-401

C6

A-401

C3

E8

C1

2C104

2C105

2C106

2C108

2C109

2C107

2C110

2C117 2C118 2C110A

2C114

2C115

2C116 2C119 2C120

2C121

C2-28

C2-27

STORAGE

2C111A

CHARTING

2C112A

CHARTING

2C113A

/2

/2

/2

/2

/2

19' - 2" 8' - 6" 15' - 8" 10' - 9 1/2"

35' - 0 1/2"

A-402

E3

A

A

B2

A

A

A

B

B2

B

B

A

B

2C111A

A

D

D

D

D

15' - 2 1/2" 12' - 1"

9' - 0" 9' - 9" 8' - 11"

STORAGE

2C114A

2C114A

B2

A-402

F4

F1

9' - 10 1/2" 15' - 0" 2' - 9 1/2"

A-401

C8

FEC

OPEN COURTYARD

OPEN COURTYARD

OPEN COURTYARD

OPEN COURTYARD

/2

/2

/2

/2

FE

A-101

B5

B

B

B1

6' - 6"

7' - 6"

3' - 0" 3' - 10"

8' - 1"

3' - 0"

3'

0"

D

16' - 6"

1' - 4"

B

9'

6"

10' - 10"

D

D

D

D

M

IN

1. ALL DIMENSIONS ARE TO FACE OF GWB, U.N.O.

2. ALL NEW WALLS ARE TO BE PARTITION TYPE A, U.N.O. SEE A-371 FOR PARTITION TYPES.

3. ALL WALLS SHALL HAVE FULL HEIGHT SOUND ATTENUATION BLANKETS, TYP. U.N.O.

4. WHEN FLOOR, WALL, AND CEILING ARE REQUIRED TO BE PATCHED, THE CONTRACTOR SHALL PATCH WITH NEW

LIKE MATERIALS TO MATCH WITH THE EXISTING ADJACENT SURFACES, UNO.

5. ALL NEW WORK SHALL BE COMPLETE AND OPERATIONAL

6. CONTRACTOR IS RESPONSIBLE FOR REROUTING ANY CONDUITS, WIRING, PLUMBING, OR PIPING AS REQUIRED TO ACHIEVE THE DESIRED LAYOUT SHOWN. NEW REROUTING LOCATIONS SHALL BE CONCEALED WITHIN WALL. WHEN IT IS IMPOSSIBLE TO CONCEAL ITEMS, LOCATE ITEMS TIGHT AGAINST WALLS-ENCLOSE ITEMS WITH GWB WITHOUT

DISRUPTION OF SERVICE TO OTHER AREAS..

7. TYPICAL WALL JAMB TO BE 4" FROM WALL AT HINGE SIDE OF DOOR U.N.O.

8. ALL PENETRATIONS/HOLES IN EXISTING OR NEW WALLS & FLOORS SHALL BE PROPERLY PATCHED TO MATCH ADJACENT AREA OR FIRESTOPPED AS REQUIRED, EVEN IF PENETRATIONS/HOLES ARE COVERED BY NEW

MILLWORK.

9. PROVIDE ALL NEW WALLS AS SHOWN IN WALL TYPES, IF THICKNESS IS DIFFERENT FROM ADJACENT EXISTING WALL, CONTRACTOR IS REQUIRED TO ADD LAYERS OF GWB TO EXG. OR NEW WALLS AS REQ'D. FOR FLUSH

CONDITION.

10. SUPPORT ALL WALL AND CEILING MOUNTED ITEMS IN ACCORDANCE WITH MANUFACTURERS RECOMMENDATIONS.

COORDINATE WITH WALL AND CEILING TYPES, TYPICAL.

11. WHERE WALL, FLOOR, CEILING ARE SCHEDULED TO REMAIN OR PARTS OF WALLS ARE DAMAGED OR OPEN DUE TO CONSTRUCTION, CONTRACTOR SHALL PATCH AND REPAIR AS REQUIRED FOR A CLEAN FINISH LOOK AND SAME PREVIOUS CONDITION. PRE ALL SURFACES WHERE ARE SCHEDULED TO RECEIVE NEW FINISHES AS REQUIRED.

12. PROVIDE BLOCKING IN ALL WALLS WHERE CABINETRY, SPECIALTY SHELVING OR A/V EQUIPMENT IS TO BE

LOCATED.

13. PROVIDE ALL NONCOMBUSTIBLE TYPE BACKING AND BLOCKING IN WALLS AND CEILINGS AS REQ'D. TO RIGIDLY SECURE ALL WALL & CEILING MOUNTED ITEMS WITH ALL WOOD BLOCKING TO BE FIRE RETARDANT TYPE. COORD.

W/OWNER AND OWNER'S SPECIAL EQUIPMENT CONTRACTOR FOR LOCATION OF ALL WALL & CEILING MOUNTED

ITEMS OTHER THAN THOSE SCHEDULED.

14. SEE MATERIAL, FINISH SCHEDULES, AND FLOORING PLANS FOR ADDITIONAL FINISH INFORMATION AND LOCATIONS

15. PREPARE WALLS TO RECEIVE FINISH AS INDICATED ON THE FINISH SCHEDULE AND APPROPRIATE SPEC. SECTION IN ACCORDANCE WITH MANUF. RECOMMENDATIONS (U.O.N.). IF OTHERWISE NOTED INSTALLATION METHOD CONFLICTS WITH MANUF. RECOMMENDATIONS NOTIFY ARCHITECT IN WRITING PRIOR TO MATERIAL ORDER, FABRICATION OR INSTALLATION.

16. SEE REFLECTED CEILING PLANS FOR ADDITIONAL CEILING MATERIAL LOCATION, AND SOFFIT LOCATIONS/HEIGHTS.

17. SMOKE BARRIERS, FIRE BARRIERS, FIRE PARTITIONS, ETC. SHALL BE CONTINUOUS FROM SLAB TO UNDERSIDE OF ROOF DECK AND SHALL BE COMPLIANT WITH REGULATIONS SET FORTH IN FBC CHAPTER 7, NFPA 101 AND ALL FED., STATE AND LOCAL CODES. PERMANENTLY LABEL AND IDENTIFY ALL FIRE WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, OR ANY OTHER PROTECTED ASSEMBLY ABOVE DECORATIVE CEILINGS AND IN CONCEALED

SPACES PER ALL FED., STATE AND LOCAL CODES.

18. PROVIDE 1/2" RADIUS BULL-NOSE CORNERS AT ALL VERTICAL GWB CORNER LOCATIONS (EXCLUDING DROP SOFFIT, CEILING LOCATIONS, AND CORNERS THAT ARE TO RECEIVE CORNER GUARDS - SEE SPECIFICATIONS FOR

ADDITIONAL INFORMATION)

19. DO NOT ATTACH AND/OR FASTEN LT. GAUGE FRAMING TO GWB WALL PARTITION MEMBRANES SUSPENDED/ FASTENED TO WALL STRUCTURE BY RESILIENT CLIPS, CHANNELS, FASTENERS, MTL FRAMING MEMBERS, ETC.-TYP.

20. PROVIDE UL APPROVED PENETRATION PROTECTION AT ALL RATED WALL ASSEMBLIES, RATED HORIZONTAL ASSEMBLIES AND ALL WALL DOUBLE TOP PLATE PENETRATIONS AS PER FBC CHAPTER AND ALL FED., STATE AND

LOCAL CODES - TYP.

GENERAL FLOOR PLAN NOTES:

NEW RATED WALL LEGEND

1-HR RATED FIRE BARRIER

2-HR RATED FIRE BARRIER

1-HR FIRE RATED SMOKE BARRIER

SMOKE PARTITION

GC TO MODIFY EXISTING REMAIN WALLS/PARTITIONS

AS REQUIRED TO MEET FIRE RATED REQUIREMENT AS

SHOWN ON NEW FLOOR PLAN

LEGEND

EXISTING CONCRETE AND / OR STUD

WALLS / PARTITIONS TO REMAIN

NEW STUD WALLS / PARTITIONS

EXISTING FIRE EXTINGUISHER

CABINET TO REMAIN

EXISTING WALL MOUNTED FIRE

EXTINGUISHER TO REMAIN

FEC

FE

24/48

3' - 4" 4' - 0"

30/36

34/41

2' - 6" 4' - 10"

ADA SIDE APPROACH

BBF

CHECK-IN

DESK

2C103

WAITING

2C102

PRIVATE

TREATMENT

2C104

D5

A-101

A D

A S

ID

E

A P

P R

O A

C H

7' - 4"

B A

D5

A-101

CRASH RAIL AS

SCHEDULED. GC TO

PROVIDE CONT. BLOCKING

AS REQUIRED FOR RIGID

CONDITION

8' CLEAR MIN. CORRIDOR

FURNITURE SYSTEM.

PROVIDE GROMMETS AS

REQUIRED. SEE ELECT.

DRAWINGS FOR ADDITIONAL

WORKS

SS-2

COORDINATE FURNITURE

SYSTEM MANUFACTURER

TO PROVIDE PL-2 WHERE

PLASTIC LAMINATE OCCURS

BBF

NOTES:

FIELD INSTALL GROMMET HOLES IN ALL BUILT

IN CABINETS FOR ELECTRICAL CORDS ALONG

WITH PROVIDING ADDITIONAL GROMMETS

WHERE INDICATED.

GROMMETS - PROVIDE A GROMMET SAT

EACH LOCATION WHERE POWER AND/OR

SIGNAL DEVICE OCCURS BELOW A

COUNTERTOP

THIS DETAIL IS TO PROVIDE CRITICAL

DIMENSIONS & NOTES. REFER TO

SPECIFICATIONS & MANUFACTURER DETAILS

FOR MORE INFORMATION.

2' - 6" OR 2'-0"

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL DRAWING SIZE (30"X42")

B

IM

/1

V A

B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a /1

V

A B ld g

A rc h

V

.r v t

/1

/2

:2

:2

P

M

A-101

PARTIAL 2ND LEVEL - FLOOR PLAN RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

4/22/2020 MWD QVL

SCALE: = 1'-0"

0 8 168

1/8"

KEYPLAN

N

SCALE: 1/8" = 1'-0"F1

PARTIAL 2ND LEVEL - NEW FLOOR PLAN

KEYNOTES - NEW

NO. DESCRIPTION

8 EXISTING 3'H POST. PROVIDE NEW DOOR OPENER

AT THE SAME LOCATION.

9 NEW PLUMBING FIXTURE AT THE EXISTING

LOCATION. REFER TO A-571 FOR MOUNTING

HEIGHTS INFORMATION

10 2 TIER METAL LOCKERS. PROVIDED & INSTALLTED

BY GC.

11 WALL MOUNTED PULLEYS AREA. PROVIDE 7' H

VENEER PLYWOOD SURFACE. COORDINATE WITH

VA FOR WIDTHS AND LOCATIONS.

KEYNOTES - NEW

NO. DESCRIPTION

1 NEW STOREFRONT PARTITION ON TOP OF 42"H

GWB PARTITION, TYP.

2 MODIFY EXISTING WALL / PARTITION TO MEET FIRE

RATED REQUIREMENT AS WALL LEGEND SHOWN.

3 REINSTALL EXISTING MEDICAL GAS RACKS.

4 PATCH AND REPAIR EXISTING WALL AS REQUIRED

TO RECEIVE NEW FINISHES AS SCHEDULED.

5 FURNITURE SYSTEM. VA PROVIDED, VA INSTALLED.

6 FURNITURE BY VA.

7 PROVIDE 3 LEVEL ADJUSTABLE METAL SHELVING

SYSTEM. MAXIMUM HEIGHT 7'-6" TO AVOID

CONFLICT WITH FIRE SPRINKLERS. REFER TO

F5/A-101 FOR BASIS OF DESIGN.

SCALE: 1/2" = 1'-0"B5

ENLARGED PLAN AT NURSE STATION

SCALE: = 1'-0"

0 2 42

1/2"

SCALE: 1 1/2" = 1'-0"D5

TYP. SECTION AT FURNITURE SYSTEM

SCALE: N.T.S.F5

BASIS OF DESIGN - ADJUSTABLE METAL SHELVING SYSTEM

SCALE: = 1'-0"1 1/2"

01 1

PROVIDED AND INSTALLED BY VA

PROVIDED AND INSTALLED BY VA

l l l l l l l l

T V

TV

l l l l

NEW RATED WALL LEGEND

1-HR RATED FIRE BARRIER

2-HR RATED FIRE BARRIER

1-HR FIRE RATED SMOKE BARRIER

SMOKE PARTITION

GC TO MODIFY EXISTING REMAIN WALLS/PARTITIONS

AS REQUIRED TO MEET FIRE RATED REQUIREMENT AS

SHOWN ON NEW FLOOR PLAN

9' - 0" A.F.F.

9' - 0" A.F.F.

9' - 0" A.F.F.

CORRIDOR

C2-30

ELEVATOR ELEVATOR ELEVATOR

STAIR

NO 4

STAIR

NO 5

COMM

2C100

EC

2C101

8' - 0" A.F.F.

8' - 6" A.F.F.

9' - 0" A.F.F.

8' - 0" A.F.F.

8' - 0" A.F.F.

9' - 0" A.F.F.

9' - 0" A.F.F.

8' - 0" A.F.F. 8' - 0" A.F.F.

8' - 0" A.F.F.

9' - 0" A.F.F.

9' - 6" A.F.F.

9' - 0" A.F.F.

9' - 0" A.F.F.

RECREATIONAL

THERAPY

2C120

STORAGE

2C114A

BREAKROOM

2C114

WOMEN

(STAFF)

2C115

MEN

(STAFF)

2C116

JAN

2C119

EL

2C118

COMM

2C117

EQUIP.

STORAGE

2C110

OCCUPATIONAL

THERAPY

(OT)

2C113

KINESIO-THERAPY

(KT)

2C112

PHYSICAL

THERAPY

(PT)

2C111

WAITING

2C102

CHECK-IN

DESK

2C103

PRIVATE

TREATMENT

2C104

STORAGE

2C105

DRIVER

THERAPY

2C106

MEN

(PATIENT)

2C108

WOMEN

(PATIENT)

2C109

MULTI-PURPOSE

ROOM

2C107CORRIDOR

C2-27

CORRIDOR

C2-28

STORAGE

2C121

CHARTING

2C112A

CHARTING

2C113A

STORAGE

2C111A

9' - 0" A.F.F.

9' - 0" A.F.F.

OPEN COURTYARD

OPEN COURTYARD

9' - 6" A.F.F.

9' - 6" A.F.F.

GENERAL RCP SHEET NOTES:

1. ALL MATERIAL EXPOSED WITHIN A RETURN AIR CEILING PLENUM SHALL BE NONCOMBUSTIBLE OR SHALL BE LIMITED IN

COMBUSTIBILITY AND HAVE A FLAME SPREAD INDEX OF 25 MAX. AND A SMOKE- DEVELOPMENT INDEX OF 50 MAX., PER ASTM E84.

2. IN LATRINES, TOILETS, LOCKER ROOMS AND JANITOR CLOSETS ALL GYPSUM BOARD CEILINGS SHALL BE WATER RESISTANT

GYPSUM BOARD.

3. ALL CEILING MOUNTED DEVICES SHALL BE CENTERED IN BOTH DIRECTIONS IN ACOUSTICAL CEILING PANELS U.N.O. CENTER SPRINKLER HEADS IN ACOUST. CEILING PANELS WHERE THEY OCCUR - COORDINATE THE LOCATION OF THE SPRINKLER HEADS WITH OTHER CEILING FIXTURES AND EQUIPMENT IN ALL CEILING. ENSURE THAT A SYMMETRICAL AND BALANCED ARRANGEMENT IS INSTALLED. CONTRACTING OFFICER IS TO REVIEW INSTANCE OF NON-EQUAL SPACING PRIOR TO

INSTALLATION.

4. CEILING GRIDS SHALL BE ORIENTED WITHIN SPACES AS SHOWN, U.N.O. FULL TILE (FT) WHERE INDICATED, SHALL ABUT

DESIGNATED WALL. LIMIT PARTIAL PANELS TO NO LESS THAN 6".

5. DEVICES HAVE BEEN SHOWN FOR COORDINATION PURPOSES. ALL DEVICES MAY NOT BE SHOWN.

6. THE CONTRACTOR SHALL ENSURE THE INSTALLATION OF ALL DEVICES INDICATED ON THE ENGR. DWG. SEE MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION DRAWINGS FOR ITEMS NOT SHOWN ON REFLECTED CEILING PLANS.

CONTACT THE ARCHITECT IF ANY CONFLICTS OCCUR.

7. AT WALLS WITH SOUND ATTENUATION BLANKETS PROVIDE SOUND ATTENUATION BLANKETS ON CEILING TO 2'-0" ON BOTH SIDES OF WALL EXCEPT AT WALLS WITH SOUND ATTENUATION BLANKETS EXTENDING TO STRUCTURE.

8. REFER TO MECH, ELEC, AND PLUMBING DRAWINGS FOR ADDITIONAL INFORMATION. PROVIDE ALL ITEMS AS REQUIRED BY

FED, STATE AND LOCAL CODE.

9. SEE GENERAL NOTES ON SHEET G-003 FOR ADDITIONAL INFORMATION.

10. SPACE CEILING GRID MAIN RUNNERS NOT MORE THAN 4'-0" O.C. AND SPACE HANGERS AT NOT MORE THAN 4'-0" O.C.

COORDINATE CEILING FRAMING WITH STRUCTURE. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION. PROVIDE ADDITIONAL HANGERS AND RUNNERS TO SUPPORT ELECTRICAL, MECHANICAL AND OTHER WORK INDICATED AND REQUIRED.

11. THE CONTRACTOR SHALL VERIFY ACCESS PANELS OF APPROPRIATE SIZE, TYPE AND RATING ARE INSTALLED IN GYP CEILINGS, SOFFITS AND IN OTHER NON-ACCESSIBLE TYPE CEILINGS OR SOFFITS WHERE ACCESS, SERVICE OR ADJUSTMENT TO MECHANICAL, PLUMBING OR ELECTRICAL ITEMS MAY BE REQUIRED AND/OR NECESSARY. ACCESS PANELS SHALL BE THE FIRE RATED TYPE EQUAL TO THE RATING OF THE CEILING OR SOFFIT IN WHICH THEY OCCUR. COORDINATE ACCESS PANELS

WITH MECHANICAL BALANCING DAMPER LOCATIONS.

REFLECTED CEILING PLAN LEGEND

2'-0" x 2'-0" ACOUSTICAL CEILING SYSTEM

SEE FINISH SCHEDULE (A-1 TO A-4)

24" X 24" MECH. RETURN AIR GRILLES

24" X 24" MECH. DIFFUSERS

INSTALL 5/8" WATER- RESISTANT GYPSUM

BOARD AT THE CEILINGS OF RESTROOMS ONLY.

ALL OTHER ROOMS INDICATED AS SUCH WILL

BE STANDARD 5/8" GYPSUM BOARD.

CEILING MOUNTED EXIT SIGN

DOWNLIGHT- CENTER IN ACOUST. CEILING

PANELS, TYP., U.N.O.

1'-0" x 5'-0" ACOUSTICAL CEILING SYSTEM

EXISTING CEILING / EXPOSED

STRUCTURAL TO REMAIN

SPRINKLER HEAD

2' X 4' EMERGENCY LIGHT FIXTURE

2' X 4' LIGHT FIXTURE

PENDANT LIGHT

CEILING MOUNTED OCCUPANT SENSOR

NURSE CALL DOME LIGHT

WALL MOUNTED SPEAKER STROBE

REINSTALL EXISTING PATIENT LIFTS &

CEILING RAILS

WALL MOUNTED STROBE

EXHAUST FAN

AREA OF WORK

2ND FLOOR

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Designed

Drawing Title

Approved:

VA FORM 08 - 6231

A

BID DOCUMENTS

FULLY SPRINKLERED

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT/ENGINEER OF RECORD STAMP

321 4 5 6 7 8 9 10

Raymond-Pond SDVOSB JV, LLC 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592

POND & Company 3500 Parkway Lane, Suite 500 Peachtree Corners, GA 30092 678-336-7740

Raymond Engineering 1224 Royal Drive, Suite 100 Conyers, GA 30094 770-483-9592Revisions: Date:

ORIGINAL DRAWING SIZE (30"X42")

B

IM

/1

V A

B ld g

S p in a l C o rd

I n ju ry

R e h a b A re a /1

V

A B ld g

A rc h

V

.r v t

/1

/2

:2

:2

P

M

A-131

PARTIAL 2ND LEVEL - REFLECTED

CEILING PLAN

RENOVATE BUILDING 7 SPINAL

CORD INJURY (SCI) REHAB AREA

VA MEDICAL CENTER, MEMPHIS, TN

614-19-102

BLDG 7

4/22/2020 MWD QVL

SCALE: = 1'-0"

0 8 168

1/8"

SCALE: 1/8" = 1'-0"F1

PARTIAL 2ND LEVEL - REFLECTED CEILING PLAN

KEYPLAN

N

KEYNOTES - REFLECTED CEILING PLAN

NO. DESCRIPTION

1 REINSTALL EXISTING PATIENT LIFTS & CEILING RAILS. COORDINATE WITH VA USERS IF CEILING RAILS NEED TO MODIFY LENGTH FOR FULLY FUNCTIONING. NOTE THAT THIS WILL NOT BE A SEPARATE PURCHASE SO GC TO BE RESPONSIBLE FOR REMOVING, STORING, REINSTALLING AND ADDING LENGTH/ MODIFYING AS REQUIRED.

PROVIDE STRUCTURAL CONNECTIONS AS REQUIRED FOR LOAD CAPCITY OF EACH LIFT. PROVIDE SIGNED AND SEALED STRUCTURAL SHOP DRAWINGS FOR APPROVAL. REFER TO A-171 FOR FURNITURE / EQUIPMENT PLAN

AND COORDINATE WITH VA FOR LOCATIONS. SEE ELECTRICAL FOR ADDITIONAL WORK.

REF.

GENERAL FURNITURE PLAN NOTES:

1. ALL FURNITURE & EQUIPMENT BY VA / NIC, UNO.

2. REFER TO OTHER DRAWINGS FOR ELECTRICAL & SECURITY SYSTEM

3. PROVIDE BLINDS/SHADES FOR ALL WINDOWS

FURNITURE LEGEND

FURNITURE &

EQUIPMENT - N.I.C

WHITE BOARD - VA PROVIDED, GC

INSTALLED. COORDINATE WITH VA FOR

LOCATION.

TACK BOARD - VA PROVIDED, GC

INSTALLED. COORDINATE WITH VA

FOR LOCATION.

WALL MOUNTED TV/MONITORS. VA

PROVIDED, GC TO PROVIDE BLOCKING FOR

RIGID CONDITION. COORDINATE WITH VA

FOR LOCATION. GC TO PROVIDE POWER &

DATA

WB

TB

TV

CORRIDOR

C2-30

ELEVATOR ELEVATOR ELEVATOR

STAIR

NO 4

STAIR

NO 5

COMM

2C100

EC

2C101

PRIVATE

TREATMENT

2C104

WAITING

2C102

STORAGE

2C105

CORRIDOR

C2-27

PHYSICAL

THERAPY

(PT)

2C111

KINESIO-THERAPY

(KT)

2C112

OCCUPATIONAL

THERAPY

(OT)

2C113 EQUIP.

STORAGE

2C110

MULTI-PURPOSE

ROOM

2C107

WOMEN

(PATIENT)

2C109

MEN

(PATIENT)

2C108

EL

2C118

COMM

2C117

STORAGE

2C121

JAN

2C119

MEN

(STAFF)

2C116WOMEN

(STAFF)

2C115

RECREATIONAL

THERAPY

2C120

BREAKROOM

2C114

CORRIDOR

C2-28

DRIVER

THERAPY

2C106

A-171

C4

A-171

F4

A-171

F7

STORAGE

2C111A

CHARTING

2C112A

CHARTING

2C113A

A-171

D7

STORAGE

2C114A

OPEN…

This is the start of the file's text. The full file is on GovTribe.