Elati_LRF_Phase_2B_Stamped_DWGS.pdf

PDF 3 MB Posted

Attached to
HVAC Replacements at Elati, Mariposa, and Security Command Center Locations (15% SBE Goal)
Solicitation number
IFB 325DH003
Issued by
Denver County, Colorado

About this file

These documents are construction documentation drawings for the Regional Transportation District's (RTD) Elati Maintenance Facility HVAC Replacements and Upgrades, Phase 2B, located at 2701 S Elati St in Denver, Colorado. The project involves comprehensive HVAC system replacements, with detailed architectural and mechanical plans prepared by HDR Engineering in Denver. The drawings, dated 12/13/2024, represent 100% construction documentation and include detailed mechanical plans for the high bay area, roof penetration details, and technical specifications for equipment installation.

The documents outline specific technical requirements for HVAC system upgrades, including precise routing and installation guidelines for roof penetrations, pipe flashings, and mechanical equipment. The plans include detailed diagrams showing spacing, attachment methods, and fire safety considerations for new HVAC infrastructure. The project appears to be part of a broader initiative to modernize and replace aging mechanical systems at the Elati Light Rail Facility, with a focus on ensuring proper installation, weatherproofing, and compliance with technical standards for commercial building mechanical systems.

View the file

Other files

Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1/

2" 1"

2"

SHEET REFERENCE

NUMBER:

4' 8' 16'

ENGINEERING DIVISION

REGIONAL TRANSPORTATION DISTRICT

1560 BROADWAY, SUITE 700

DENVER, CO 80202

(303) 628-9000

/1

3/

:2 8:

P

M \\d en -s rv 1\

N ew fo rm a\

4\

\1

9\ 6.

0_ C

A D

_B

IM

\6 .2

_W

IP

\R T

D _M ec h

U pg ra de s.

rv t

G0003-2B-B

COVER SHEET

HDR Engineering Denver 1670 Broadway, Suite 3400 Denver, CO 80202-4824

ELATI MAINTENANCE FACILITY

2701 S Elati St, DENVER, CO 80110

100% CONSTRUCTION DOCUMENTATION

ELATI LRF HVAC REPLACEMENTS AND UPGRADES

ELATI LRF HVAC REPLACEMENTS AND UPGRADES

PHASE 2B

MARK REVISIONS BY DATE

4 50% DESIGN DEVELOPMENT 10/18/2024

5 100% CONSTRUCTION DOCUMENTATION 12/13/2024

THE REGIONAL TRANSPORTATION DISTRICT

M-001-2B

MECHANICAL COVER SHEET

1/2

1"

2"

SHEET REFERENCE

NUMBER:

4' 8' 16'

FILE NAME:

HORZ SCALE:

VERT SCALE:

ENGINEERING DIVISION

REGIONAL TRANSPORTATION DISTRICT

1560 BROADWAY, SUITE 700

DENVER, CO 80202

(303) 628-9000

/2/

3:

:37 P

M \\d en -sr v1 \N ew for ma \15

4\1

4\1

9\6

.0_

CA

D_

BI

M\ 6.2

_W

IP

\R

TD

_M ec h U pg ra de s.r vt

ELATI LRF HVAC REPLACEMENT AND UPGRADES

PHASE 2B

HDR Engineering

Denver

1670 Broadway, Suite 3400

Denver, CO

80202-4824

MARK REVISIONS BY DATE

4 50% DESIGN DEVELOPMENT 10/18/2024

5 100% CONSTRUCTION DOCUMENTATION 12/13/2024

EAB

EAB

12-13-20

M-101-2B

HVAC HIGH BAY PLAN

0 4' 8' 16'

HVAC HIGH BAY PLAN

1/2

1"

2"

SHEET REFERENCE

NUMBER:

4' 8' 16'

FILE NAME:

HORZ SCALE:

VERT SCALE:

ENGINEERING DIVISION

REGIONAL TRANSPORTATION DISTRICT

1560 BROADWAY, SUITE 700

DENVER, CO 80202

(303) 628-9000

/2/

3:

:37 P

M \\d en -sr v1 \N ew for ma \15

4\1

4\1

9\6

.0_

CA

D_

BI

M\ 6.2

_W

IP

\R

TD

_M ec h U pg ra de s.r vt

ELATI LRF HVAC REPLACEMENT AND UPGRADES

PHASE 2B

HDR Engineering

Denver

1670 Broadway, Suite 3400

Denver, CO

80202-4824

MARK REVISIONS BY DATE

4 50% DESIGN DEVELOPMENT 10/18/2024

5 100% CONSTRUCTION DOCUMENTATION 12/13/2024

EAB

EAB

12-13-20

PRE-MOLDED QUICKSEAM PIPE

FLASHING / PIPE BOOT, ATTACHMENT

TO ROOFING MEMBRANE AS PER

MANUFACTURERS' REQUIREMENTS

STAINLESS STEEL CLAMP RING

CONTINUOUS BEAD OF HIGH GRADE

URETHANE SEALANT

ROOFING MEMBRANE SHALL EXTEND

A MIN. OF 1" UP PIPE

ROOFING MEMBRANE PATCH HEAT

ATTACHED IN PLACE. MEMBRANE MUST

BE A MIN OF 4" LARGER THAN

DIAMETER OF PIPE FLASHING, PER

MANUFACTURERS' RECOMMENDATION

PIPE EXTENDS ABOVE FLASHING

COLLAR

P.A. TO VERIFY THE

REQUIREMENT FOR

AIR / VAPOR BARRIER

MEMBRANE OVER

ROOF STRUCTURE

P.A. TO VERIFY THE ROOFING

SYSTEM TYPE

ROOFING SYSTEM AS SPECIFIED

ROOF STRUCTURE

TOP OF ROOF

07 84 00a

Through Penetration Firestop System12" MINIMUM

12" MINIMUM

12" MINIMUM

2'-0" MINIMUM

NOTES:

1. THESE DIMENSIONS ARE INTENDED

TO PROVIDE MINIMUM CLEARANCES TO

ALLOW FOR PROPER FLASHING. LARGER

DIMENSIONS MAY BE REQUIRED.

2. ALL PENETRATIONS SHALL BE RIGID,

ROUND OR SQUARE TUBE AND EXTEND

PERPENDICULAR FROM THE SURFACE

OF THE ROOF.

ROOF DECK

PARAPET WALL OR

WALL ASSEMBLY

DIAGRAMS ARE ILLUSTRATIVE.

SEALANT AROUND, TYPICAL

VENT PIPE CAP WITH BIRD SCREEN

APPROVED THROUGH WALL THIMBLE

EXISTING WALL

STRUCTURAL MOUNT SUPPORT INSIDE OF WALL

36" MINIMUM

EXTERIORINTERIOR

PIPE CONNECTION PER SPEC.

THROUGH WALL EXHAUST VENT PIPE

1/

2" 1"

2"

SHEET REFERENCE

NUMBER:

ENGINEERING DIVISION

REGIONAL TRANSPORTATION DISTRICT

1560 BROADWAY, SUITE 700

DENVER, CO 80202

(303) 628-9000

/1

3/

:2 8:

P

M \\d en -s rv 1\

N ew fo rm a\

4\

\1

9\ 6.

0_ C

A D

_B

IM

\6 .2

_W

IP

\R T

D _M ec h

U pg ra de s.

rv t

A-500

ROOF DETAILS

1 1/2" = 1'-0" 2

PREMANUFACTURED PIPE FLASHING @ ROOF PENETRATION - SECTION

1" = 1'-0" 3

ROOF PENETRATION SPACING DIAGRAM

1 1/2" = 1'-0" 1 Wall Penetration Detail

MARK REVISIONS BY DATE

4 50% DESIGN DEVELOPMENT 10/18/2024

5 100% CONSTRUCTION DOCUMENTATION 12/13/2024

Sheets and Views
HVAC SHEETS - PHASE 2B-M-001
temp
HVAC SHEETS - PHASE 2B-M-101
temp

File details come from the government source that posted it. Updated .