CULVERT INSPECTION REPORT
DODD CREEK CULVERT
BLUE RIDGE PARKWAY OVER DODD CREEK
BLUE RIDGE PARKWAY
LN
STRUCTURE NO. 5140-051P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 10/17/12
Report prepared by: EU
MILE POINT: 162.00
Federal Highway Administration KILOMETER POINT: 260.71 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 http://www.efl.fhwa.dot.gov/FLHBO/BIP http://www.efl.fhwa.dot.gov/FLHBO/BIP
STRUCTURE SUMMARY STRUCTURE NO. 5140-051P
DODD CREEK CULVERT INSPECTION DATE: 10/17/12
CULVERT IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ........ CONCRETE CONTINUOUS NO. OF BARRELS:
FOUNDATION: ....................... SPREAD FTG ON BEARING MAT'L BARREL LENGTH: ............... 46 FT (14 M)
STRUCT. TOTAL LENGTH: ... 25.4 FT (7.7 M) SKEW ANGLE: ..................... 24 °
MAX. SPAN LENGTH: ............ 11.3 FT (3.4 M) YEAR BUILT:
PROJ./PLAN REF. NO: .......... 000000000000 / NONE YEAR RECONSTRUCTED: .. N/A
NPS ROAD CLASS: ............... 1 - PRINCIPAL PARK ROAD
STRUCTURE HISTORY:
LOCATION
BLUE RIDGE PARKWAY MILE POINT: ..................... 162.00 (KM PT 260.71)
STATE: .................................. VIRGINIA LOCATION: 0.7 MILES TO VA ROUTE 615
FACILITY CARRIED: ............. BLUE RIDGE PARKWAY
FEATURE INTERSECTED: ... DODD CREEK
STRUCTURE EVALUATION SUMMARY
This double barrel concrete box culvert is in fair condition overall. Problems include a moderate accumulation of drift in the north barrel, which has diverted the stream flow into the south barrel and caused minor scour; the scour has exposed the downstream end of the barrel floor. In addition, there is moderate scaling of the south barrel floor slab with exposed rebar, minor deterioration of the headwall and wingwall masonry mortar joints, and mortar missing between the masonry and concrete floor slab at the upstream end of the north barrel.
Corrective action should be taken as outlined in this report to prevent the possible development of more serious or costly problems in the future. In addition, consideration should be given to installing a guardrail system over the structure and approaches to help improve motorist safety.
Since the previous inspection, the mile marker in the west shoulder has been replaced, and a missing stone at the downstream end of the south wall of the south barrel has been replaced.
INSPECTION TEAM: M. BELL, A. HAVARD (VOLKERT, INC.)
CONDITION ASSESSMENT:
MATTHEW BELL, P.E., FIELD TEAM LEADER
REPORT REVIEW:
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
REPORT APPROVAL: DATE: 2/28/13
MARCUS MILLER, P.E., SENIOR INSPECTION ENGINEER 703-404-6252
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-051P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
D226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
62.3,4 CLEAN AND REPOINT MASONRY MORTAR JOINTS AS NECESSARY. 1 LS $
61.1,4, 62.5,6
REMOVE DRIFT AND VEGETATION FROM NORTH BARREL, THEN REDIRECT
CHANNEL INTO BOTH BARRELS.
1 LS
62.1 CLEAN EXPOSED REBAR IN SOUTH BARREL AND COAT WITH APPROVED
PROTECTIVE SEALANT.
1 LS
62.1 PATCH VOID BETWEEN MASONRY AND CONCRETE FLOOR SLAB ON EAST END OF
NORTH WALL OF NORTH BARREL.
1 LS
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
62.9, 222.3, 36.A
INSTALL GUARDRAIL SYSTEM OVER STRUCTURE AND AT
APPROACHES.
1 LS $0
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : $0
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
ESTIMATE TOTAL* :
REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 5140-051P
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
STREAM BED COMPOSITION :9.
AVG. CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION 3.
EROSION AND/OR SCOUR 2.
ALIGNMENT 1.
61. CHANNEL 6
F F N F
4 FT.
MED
SUFF
N
ITEM REFERENCE AND REMARKS
62. CULVERT 6
PARAPETS AND/OR RAILINGS 9.
ADEQUACY OF COVER 8.
SETTLEMENT AND/OR DEFLECTION 7.
EROSION AND/OR SCOUR 6.
DEBRIS AND/OR SILT 5.
WINGWALLS 4.
HEADWALLS 3.
FOOTINGS 2.
BARREL(S)1.
ROADWAY SURFACE 10.
RIDEABILITY 11.
OTHER 12.
F N F F F F G G N G G N
222. APPROACHES 7
OTHER 9.
ALIGNMENT 8.
SIGNS 7.
SETTLEMENT 6.
EROSION 5.
SURFACING 4.
APPROACH GUARDRAIL 3.
RELIEF JOINTS 2.
1. APPROACH SLABS N
N N G G G G G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION 5.
EROSION AND/OR SCOUR 4.
FOUNDATION 3.
WEEP HOLES 2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAILS C.
TRANSITIONS B.
BRIDGE RAILINGSA.
APPROACH GUARDRAIL ENDS D.
SAND, STONES
61.1,4, 62.5 MODERATE ACCUMULATION OF DRIFT (APPROXIMATELY 6" HIGH) IN
NORTH BARREL. HEAVY DEBRIS ACCUMULATION AND VEGETATION
AT UPSTREAM END OF NORTH BARREL HAS DIVERTED FLOW TO
SOUTH BARREL ONLY.
61.2 MINOR EROSION OF SOUTH DOWNSTREAM CHANNEL BANK BEHIND
WINGWALL. MODERATE EROSION WITH TREES UNDERMINED ON
NORTH DOWNSTREAM CHANNEL BANK APPROXIMATELY 50' FROM
STRUCTURE. MINOR SCOUR AND UNDERMINING OF SOUTH
UPSTREAM CHANNEL BANK ALONG STACKED STONES.
62.1 MINOR LONGITUDINAL CRACKING WITH EFFLORESCENCE ON SLAB
UNDERSIDE, ADJACENT TO HEADWALL AT EAST END OF BOTH
BARRELS. MINOR TO MODERATE EFFLORESCENCE FROM MORTAR
JOINTS BETWEEN RING STONES AND CONCRETE SLAB.
MINOR CRACKING WITH EFFLORESCENCE ON BARREL WALL
MASONRY MORTAR JOINTS. MINOR HORIZONTAL CRACKING WITH
EFFLORESCENCE ALONG BASE OF EXTERIOR CONCRETE BARREL
WALLS. MORTAR MISSING WITH SOIL LEACHING BETWEEN
MASONRY AND CONCRETE FLOOR SLAB AT EAST END OF NORTH
WALL.
MODERATE SCALING OF SOUTH BARREL CONCRETE FLOOR WITH
EXPOSED REBAR IN ISOLATED LOCATIONS.
62.3 MINOR CRACKING AND DETERIORATION OF HEADWALL MASONRY
MORTAR JOINTS WITH EFFLORESCENCE; SEVERAL JOINTS HAVE
PREVIOUSLY BEEN REPOINTED. MODERATE MOSS GROWTH ON
WEST HEADWALL.
MINOR TO MODERATE EFFLORESCENCE FROM RING STONE
MASONRY MORTAR JOINTS.
62.4 MINOR TO MODERATE DETERIORATION OF WINGWALL MASONRY
MORTAR JOINTS WITH EFFLORESCENCE AND VEGETATION
GROWTH IN SEVERAL JOINTS.
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required. 3 OF 20
FIELD INSPECTION REPORT STRUCTURE NO. 5140-051P
ADDITIONAL ITEM REFERENCE AND REMARKS
62.6 APPROXIMATELY 8" OF SOUTH BARREL FLOOR EXPOSED ON DOWNSTREAM END. STONE AT DOWNSTREAM END
OF SOUTH WALL OF SOUTH BARREL HAS BEEN REPLACED SINCE PREVIOUS INSPECTION.
62.10, 222.4 MINOR TO MODERATE TRANSVERSE AND LONGITUDINAL CRACKING OF ASPHALT PAVEMENT.
222.7 "162" MILE MARKER POST ON WEST SHOULDER HAS BEEN REPLACED.
36 NO APPROACH GUARDRAIL SYSTEM PRESENT.
STRUCTURE LOAD RATING STRUCTURE NO. 5140-051P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 15 14 25 23
HS 27 24 45 41
TYPE 3 28 25 46 42
TYPE 3S2 44 40 73 66
TYPE 3-3 54 49 89 81
DESIGN LOADING: UNKNOWN (H15 ASSUMED - SEE REMARKS)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: DESIGN LOADING IS UNKNOWN; ASSUMPTION IS BASED ON STRUCTURE TYPE, LOCATION, AGE, AND
CONDITION.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-051P
STRUCTURE IDENTIFICATION
(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 513 - VIRGINIA (VA)
(202) STRUCTURE NAME: .......... DODD CREEK CULVERT (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 2 - CULVERT (3) COUNTY CODE: ........................ 063 - FLOYD
(204) STRUCTURE NUMBER: ..... 5140-051P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... DODD CREEK
(207) ROAD SECTION NO: .......... 051P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140051P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 0.7 MILES TO VA ROUTE 615
(210) OPERATING UNIT: ............. ROCKY KN (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ 000000000000 (11) MILE POINT: ............................. 162.00 (KM PT 260.71)
(212) DRAWING NUMBERS: ....... NONE (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
2 - CONCRETE CONTINUOUS
19 - CULVERT
11.3 FT (3.4 M)
25.4 FT (7.7 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
6 - N/A
N - NOT APPLICABLE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. N - NOT APPLICABLE
B) TYPE MEMBRANE: ................. N - NOT APPLICABLE
C) TYPE PROTECTION: .............. N - NOT APPLICABLE
(218) IS SALT USED?: ..................... YES
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 0 - UNKNOWN (41) LOAD RESTRICTION: ......... R - POSTED (OTHER)
(66) INVENTORY RATING: ...... 27.0 TONS (24.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 45.0 TONS (40.8 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 10/12 (91) FREQ. OF INSP: 48 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-051P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE: ............................. 36°52'04.00" (51) CURB TO CURB WIDTH: ........... 0.0 FT (0.0 M)
(17) LONGITUDE: ......................... 80°16'58.70" (52) DECK WIDTH: ............................ 0.0 FT (0.0 M)
(19) DETOUR LENGTH: ............... 3 MI (5 KM) (32) APPR. ROADWAY WIDTH: ........ 29.0 FT (8.8 M)
(28A) LANES ON STRUCT: .......... 02 (213) APPR. PAVEMENT WIDTH: ..... 21.0 FT (6.4 M)
(28B) LANES UNDER STRUCT: ... 00 LEFT SHOULDER: .................. 4.0 FT (1.2 M)
(42A) SERVICE ON: ..................... 1 - HIGHWAY RIGHT SHOULDER: ................ 4.0 FT (1.2 M)
(42B) SERVICE UNDER: .............. 5 - WATERWAY (33) BRIDGE MEDIAN: ....................... 0 - NO MEDIAN
(29) AVG. DAILY TRAFFIC: .......... 1061 (34) SKEW ANGLE: ............................ 24 °
(30) YEAR OF ADT: ...................... 2012 (35) DECK FLARE?: ........................... NO
(114) FUTURE ADT: ..................... 1167 (47) TOTAL HORIZ. CLEARANCE: .... 29.0 FT (8.8 M)
(115) YEAR OF FUTURE ADT: ..... 2032 (50) SIDEWALKS:
(101) PARALLEL STRUCTURE: ... N - NONE LEFT : ...................................... 0.0 FT (0.0 M)
(38) NAVIGATION CONTROL?: ... 0 RIGHT : ................................... 0.0 FT (0.0 M)
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M) (214) BRIDGE RAIL TYPE:
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M) RAIL CONFIGURATION: ......... 0 - N/A
(111) ABUT. OR PIER PROT: ....... MATERIAL: .............................. 0 - N/A
DESIGN TYPE: ........................ 0 - N/A
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 0.0 FT (0.0 M) (215) BRIDGE RAIL HEIGHT: ............ 0.00 FT (0.00 M)
(56) LEFT: ......................... 0.0 FT (0.0 M) (53) MIN. VRT. CLEAR. OVER DECK: 99.99 FT (99.99 M)
(54) MIN. VRT. UNDERCLEARANCE: 0.00 FT (0.00 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK: ................................. N
(59) SUPERSTRUCTURE: ......... N
(60) SUBSTRUCTURE: .............. N
(61) CHANNEL:
(62) CULVERT:
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 0000
(75A) TYPE OF WORK:
(75B) WORK DONE BY:
(76) IMPROVEMENT LENGTH: ..
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
8 - Stable; scour above top of fo
2 - REHAB/RECONSTRUCTION
D - MINOR
$0
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
http:80�16'58.70 http:36�52'04.00
APPENDIX STRUCTURE NO. 5140-051P
PHOTOGRAPHS STRUCTURE NO. 5140-051P
PHOTO #1 - LOOKING SOUTHBOUND TOWARD CUMBERLAND KNOB
FLOW
PHOTO #2 - WEST (DOWNSTREAM) SIDE
PHOTO #3 - GENERAL TOP SIDE VIEW LOOKING NORTH
PHOTO #4 - GENERAL UNDERSIDE VIEW OF SOUTH BARREL LOOKING
WEST
PHOTO #5 - TYPICAL TRANSVERSE AND LONGITUDINAL CRACKING OF
PAVEMENT OVER STRUCTURE, SOUTHBOUND LANE SHOWN
PHOTO #6 - MILE MARKER HAS BEEN REPLACED SINCE PREVIOUS
INSPECTION
PHOTO #7 - DEBRIS ACCUMULATION AT UPSTREAM END OF NORTH
BARREL
PHOTO #8 - TYPICAL MOSS GROWTH AND EFFLORESCENCE ON
HEADWALL MASONRY, EAST END SHOWN
PHOTO #9 - TYPICAL DETERIORATION OF WINGWALL MASONRY
MORTAR JOINTS, NORTHEAST WINGWALL SHOWN; NOTE MOSS
GROWTH
PHOTO #10 - TYPICAL EFFLORESCENCE ON RING STONES, EAST END
OF SOUTH BARREL SHOWN
PHOTO #11 - CRACKING WITH
EFFLORESCENCE ON SLAB UNDERSIDE AT
EAST END OF SOUTH BARREL
PHOTO #12 - TYPICAL CRACKING WITH
EFFLORESCENCE ON MASONRY BARREL
WALLS, EAST END OF SOUTH BARREL WALL
SHOWN
PHOTO #13 - VOID UNDER MASONRY AT INTERSECTION OF
NORTHEAST WINGWALL AND NORTH BARREL WALL
PHOTO #14 - CRACKING WITH EFFLORESCENCE ON SOUTH BARREL
WALL NEAR EAST END
PHOTO #15 - DEBRIS ACCUMULATION IN NORTH BARREL
PHOTO #16 - TYPICAL SCALING OF CONCRETE FLOOR WITH EXPOSED
REBAR, WEST END OF SOUTH BARREL NEAR CENTER WALL SHOWN
PHOTO #17 - SCOUR AT WEST END OF SOUTH BARREL; NOTE
EXPOSED FLOOR
PHOTO #18 - TYPICAL VEGETATION GROWTH ON HEADWALL
MASONRY, WEST HEADWALL SHOWN
PHOTO #19 - GENERAL VIEW OF SOUTH UPSTREAM CHANNEL BANK;
NOTE UNDERMINED STONES
PHOTO #20 - SCOUR AND UNDERMINING OF NORTH DOWNSTREAM
CHANNEL BANK
PHOTO #21 - VEGETATION GROWTH AND DEBRIS ACCUMULATION AT
DOWNSTREAM END OF NORTH BARREL
PHOTO #22 - UPSTREAM CHANNEL
PHOTO #23 - DOWNSTREAM CHANNEL