BRIDGE INSPECTION REPORT
BACK CREEK BRIDGE
BLUE RIDGE PARKWAY OVER BACK CREEK & VA ROUTE 613
BLUE RIDGE PARKWAY
LN
STRUCTURE NO. 5140-040P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 10/26/14
Report prepared by: ED
MILE POINT: 124.36
Federal Highway Administration KILOMETER POINT: 200.28 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 5140-040P
BACK CREEK BRIDGE INSPECTION DATE: 10/26/14
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... PRESTRESSED CONCRETE NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: ..
DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH:
WEARING SURFACE: .......... BITUMINOUS DECK W IDTH:
ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB W IDTH:
PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: ..
PROJ./PLAN REF. NO: ......... 1N6,7 / 3026 SKEW ANGLE:
NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL:
STRUCTURE HISTORY: ...... 1984-JOINT REPAIR. 2010-APPROACHES REPAVED.
LOCATION
301.0 FT (91.7 M)
100.0 FT (30.5 M)
32.8 FT (10.0 M)
26.0 FT (7.9 M)
N/A
0 °
NO
BLUE RIDGE PARKWAY MILE POINT: ..................... 124.36 (KM PT 200.28)
STATE: ................................. VIRGINIA LOCATION: 0.2 MILES TO VA ROUTE 690
FACILITY CARRIED: ............ BLUE RIDGE PARKWAY
FEATURE INTERSECTED: .. BACK CREEK & VA ROUTE 613
STRUCTURE EVALUATION SUMMARY
This prestressed concrete multi-girder bridge is in fair condition overall. Though not observed during this inspection due to dry conditions, there is evidence of heavy leakage through the deck expansion joints onto the superstructure and substructure components below; these joints should be cleaned and resealed to prevent further leakage onto the structure below deck. Additionally the asphalt wearing surface exhibits minor to moderate widespread longitudinal and map cracking and should be replaced in the near future.
Other problems include, erosion of the abutment slopes, an exposed footing at the west column of the north pier, vine and other vegetation growth on the structure, and clogged deck drains. In addition, there are several areas of minor spalling with exposed rebar, including on the bottom flange of Girder #1 at the south abutment, on the north and east faces of the east column in the north pier, and on the wingwalls. It should also be noted that the deck drains do not extend beyond the bottom flange of the girders and several appear to drain in close proximity to some of the pier bearings; the drains should be extended to prevent further leakage onto the structural elements below.
Repairs should be made as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: E.A. JARRELL, J.W . ELLENOR (CLARK NEXSEN)
CONDITION ASSESSMENT:
E. ALEX JARRELL, FIELD TEAM LEADER
REPORT REVIEW :
GARY J. GOODLIN, FIELD TEAM LEADER 703-404-6253
REPORT APPROVAL: DATE: 3/31/15
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-040P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
D226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
60.9,17 STABILIZE EROSION ON ABUTMENT SLOPES WITH ENGINEERED RIPRAP.
PROTECT EXPOSED WEST COLUMN FOOTING AT NORTH PIER WITH ENGINEERED
RIPRAP.
25 CY
58.7 EXTEND DECK DRAINS BEYOND GIRDERS AND AWAY FROM BEARINGS. 1 LS
58.1,2,7, 60.13
REMOVE VEGETATION GROWTH ON STRUCTURE. REMOVE DEBRIS FROM
EXPANSION JOINTS, CURBLINES, SIDEWALKS, AND DECK DRAINS.
1 LS
59.2, 60.6,13
CLEAN AND SEAL EXPOSED REBAR ON GIRDER #1 AT SOUTH ABUTMENT, NORTH
AND EAST FACES OF EAST COLUMN IN NORTH PIER, AND ON WINGWALLS WITH
APPROVED COATING.
15 SF
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
58.3 REPLACE WEARING SURFACE. 1 LS $0
58.2 CLEAN AND RESEAL DECK EXPANSION JOINTS. 1 LS $0
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : $0
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. REHABILITATION TOTAL:
PRELIM. RECONSTRUCTION TOTAL: ...
TOTAL ITEMIZED COSTS:
$0
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 5140-040P
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N NOT APPLICABLE
9 EXCELLENT CONDITION
8 VERY GOOD CONDITION - no problems noted.
7 GOOD CONDITION - some minor problems.
6 SATISFACTORY CONDITION - structural elements show some minor deterioration.
5 FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
0 FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
58. DECK 6
1. DECK SLAB F
2. EXPANSION JOINTS F
3. WEARING SURFACE F
4. RIDEABILITY G
5. CURBS, SIDEWALKS, AND MEDIAN G
6. PARAPETS AND/OR RAILINGS G
7. DRAINS AND DRAINAGE P
8. UTILITIES N
9. DEFLECTION AND/OR VIBRATION G
10. OTHER N
59. SUPERSTRUCTURE 7
1. BEARING DEVICES
2. GIRDERS OR BEAMS
3. ARCH(ES) OR SLAB(S)
4. FLOOR BEAMS AND STRINGERS
5. TRUSSES
6. DIAPHRAGMS AND BRACING
7. PAINT
8. FASCIA(E)
9. DEFLECTION AND/OR VIBRATION
10. ALIGNMENT
11. OTHER
60. SUBSTRUCTURE
ABUTMENTS
1. BREASTWALLS OR COLUMNS
2. PILE BENTS
3. CAPS AND/OR BEARING SEATS
4. BACKWALLS AND/OR BULKHEADS
5. FOUNDATIONS
6. WINGWALLS
7. WEEP HOLES
8. EXPANSION JOINTS
9. EROSION AND/OR SCOUR
10. SETTLEMENT OR DEFLECTION
11. SLOPE PROTECTION
12. OTHER
PIER(S)
13. WALLS AND/OR COLUMNS
14. PILE BENTS
15. CAPS AND/OR BEARING SEATS
16. FOUNDATIONS (CONCRETE FTG)
17. EROSION AND/OR SCOUR
18. SETTLEMENT OR DEFLECTION
19. OTHER
G G N N N G N N G G N
F N G G N G G N F G N N
G N G G F G N
58.1
58.1,2, 60.4
58.2
58.2, 59, 60
58.3
58.5
58.6
58.7
59.1
ITEM REFERENCE AND REMARKS
MINOR EFFLORESCENCE ON DECK UNDERSIDE, WEST BAY OF
NORTH SPAN. MODERATE TO HEAVY VINE GROWTH ON WEST SIDE
OF NORTH SPAN AND BOTH SIDES OF CENTER AND SOUTH SPANS.
MODERATE VINE GROWTH ON DECK UNDERSIDE, CENTER BAY OF
SOUTH SPAN. EXPOSED AND RUSTED REBAR CHAIRS
THROUGHOUT SPAN #3 DECK UNDERSIDE.
MINOR EDGE SPALLING AND TRANSVERSE CRACKING OF DECK
HEADERS AND NORTH ABUTMENT BACKWALL AT EXPANSION
JOINTS.
LOOSE COMPRESSION SEALS OVER ABUTMENTS AT AREAS OF
EDGE SPALLING. MINOR TO MODERATE DEBRIS ACCUMULATION IN
JOINTS. MINOR RUSTING OF SLIDING PLATE JOINTS OVER PIERS.
HEAVY STAINING ON SUPERSTRUCTURE AND SUBSTRUCTURE
COMPONENTS UNDER EXPANSION JOINTS INDICATING LEAKAGE
THROUGH JOINTS.
MINOR TO MODERATE WIDESPREAD LONGITUDINAL AND MAP
CRACKING OF WEARING SURFACE. MINOR DETERIORATION OF
WEARING SURFACE ALONG CURBLINES.
MINOR TRANSVERSE CRACKING OF APPROACH SIDEWALKS.
MINOR SPALL IN EAST CURB AT MIDSPAN OF NORTH SPAN.
MINOR VERTICAL CRACKING OF PARAPETS; MINOR MOSS GROWTH.
MINOR TO MODERATE VERTICAL AND TRANSVERSE CRACKING
WITH EFFLORESCENCE ON APPROACH PARAPETS.
MOST DECK DRAINS FILLED WITH DEBRIS AND VEGETATION.
MINOR ACCUMULATION OF SOIL, DEBRIS, VEGETATION, AND MOSS
GROWTH ALONG CURBLINES AND SIDEWALKS. DECK DRAINS DO
NOT EXTEND PAST GIRDERS; SEVERAL DRAINS NEAR PIER
BEARINGS; SEE ALSO 59.2.
MINOR RUSTING OF BEARING SOLE PLATES.
FIELD INSPECTION REPORT STRUCTURE NO. 5140-040P
ITEM REFERENCE AND REMARKS
STREAM BED COMPOSITION : 9.
AVERAGE CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION 3.
EROSION AND/OR SCOUR 2.
ALIGNMENT 1.
61. CHANNEL 8
G G G G N
MED
SUFF
28 FT.
ROCK, GRAVEL
222. APPROACHES 7
OTHER 9.
ALIGNMENT 8.
SIGNS 7.
SETTLEMENT 6.
EROSION 5.
SURFACING 4.
APPROACH GUARDRAIL 3.
RELIEF JOINTS 2.
1. APPROACH SLABS N
N N G G G N G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION 5.
EROSION AND/OR SCOUR 4.
FOUNDATION 3.
WEEP HOLES 2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDS D.
APPROACH GUARDRAILS C.
TRANSITIONS B.
BRIDGE RAILINGSA. 1
N N N
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety feature is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety feature is not required.
59.2 MODERATE STAINING AND LEAKAGE ON BOTTOM FLANGE OF
GIRDER #1 IN NORTH AND CENTER SPANS BELOW DECK DRAINS.
MINOR EFFLORESCENCE ON GIRDER #3 IN NORTH SPAN NEAR
NORTH PIER. MINOR SPALL WITH EXPOSED REBAR ON UNDERSIDE
OF GIRDER #1 AT SOUTH ABUTMENT.
60.1 MINOR VERTICAL CRACKING WITH EFFLORESCENCE ON
BREASTWALLS; MINOR SCALING. TWO MINOR SPALLS ON NORTH
BREASTWALL. MINOR HORIZONTAL CRACKING WITH
EFFLORESCENCE ON BOTH SIDES OF SOUTH BREASTWALL. MINOR
DELAMINATION NEAR WEST SIDE OF SOUTH BREASTWALL.
60.3 MINOR ACCUMULATION OF DEBRIS ON BEARING SEATS.
60.4 MINOR TRANSVERSE CRACKING AND EDGE SPALLING OF TOP FACE
OF ABUTMENT BACKWALLS. MINOR VERTICAL CRACKING OF
BACKWALLS, SOME WITH EFFLORESCENCE.
60.6 MINOR CRACKING WITH EFFLORESCENCE AND ISOLATED SPALLING
WITH EXPOSED REBAR ON WINGWALLS, SOME DUE TO
INSUFFICIENT CONCRETE COVER.
60.9 PREVIOUSLY NOTED EROSION ALONG NORTHEAST WINGWALL
FILLED WITH GRAVEL SINCE LAST INSPECTION. MINOR EROSION
OF NORTH ABUTMENT SLOPE, UP TO 2' DEEP. MINOR EROSION OF
SOUTH ABUTMENT SLOPE UNDER DECK DRAIN, UP TO 2' DEEP.
60.13 MINOR VERTICAL CRACKING WITH EFFLORESCENCE ON PIER
COLUMNS; MINOR TO MODERATE VINE GROWTH. POPOUTS WITH
EXPOSED REBAR THROUGHOUT. MINOR SPALLING WITH EXPOSED
WIRE ON NORTH AND EAST FACES OF EAST COLUMN IN NORTH
PIER.
60.15 MODERATE STAINING ON PIER CAPS. MINOR VERTICAL CRACKING
WITH EFFLORESCENCE ON NORTH FACE OF NORTH PIER CAP
ABOVE EAST COLUMN.
60.17 WEST COLUMN FOOTING AT NORTH PIER EXPOSED UP TO 10" HIGH
AT SOUTHEAST CORNER.
222.5 MINOR EROSION AT SOUTHEAST WINGWALL END.
222.7 "BACK CREEK" SIGNS POSTED AT BOTH APPROACHES.
STRUCTURE LOAD RATING STRUCTURE NO. 5140-040P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 15 14 25 23
HS 22 20 37 34
TYPE 3 21 19 36 33
TYPE 3S2 26 24 43 39
TYPE 3-3 28 25 47 43
DESIGN LOADING: H15 (M13.5)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-040P
STRUCTURE IDENTIFICATION
(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 513 - VIRGINIA (VA)
(202) STRUCTURE NAME: .......... BACK CREEK BRIDGE (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 161 - ROANOKE
(204) STRUCTURE NUMBER: ..... 5140-040P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... BACK CREEK & VA ROUTE 6
(207) ROAD SECTION NO: .......... 040P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140040P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 0.2 MILES TO VA ROUTE 690
(210) OPERATING UNIT: ............. ROANOKE (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ 1N6,7 (11) MILE POINT: ............................. 124.36 (KM PT 200.28)
(212) DRAWING NUMBERS: ....... 3026 (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
5 - PRESTRESSED CONCRETE
02 - STRINGER/MULTI-BEAM or GIRDER
100.0 FT (30.5 M)
301.0 FT (91.7 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
1 - CONCRETE CAST-IN-PLACE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 6 - BITUMINOUS
B) TYPE MEMBRANE: ................. 0 - NONE
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... YES
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 2 - H15 (M13.5) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 22.0 TONS (20.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 37.0 TONS (33.6 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 10/14 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-040P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(51) CURB TO CURB WIDTH: ........... 26.0 FT (7.9 M)
(16) LATITUDE: ............................. 37°11'36.50"
(17) LONGITUDE: ......................... 80°00'02.80"
(19) DETOUR LENGTH: ............... 26 MI (42 KM)
(28A) LANES ON STRUCT:
(28B) LANES UNDER STRUCT: ... 02
(42A) SERVICE ON: ..................... 5 - HIGHWAY-PEDESTRIAN
(42B) SERVICE UNDER: .............. 6 - HIGHWAY-WATERWAY
(29) AVG. DAILY TRAFFIC:
(30) YEAR OF ADT:
(114) FUTURE ADT:
(115) YEAR OF FUTURE ADT:
(101) PARALLEL STRUCTURE: ... N - NONE
(38) NAVIGATION CONTROL?: ... 0
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)
(111) ABUT. OR PIER PROT:
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 5.6 FT (1.7 M)
(56) LEFT: ......................... 0.0 FT (0.0 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL:
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 1NNN
(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB
(75B) WORK DONE BY: ............. 1 - CONTRACT
(76) IMPROVEMENT LENGTH: .. 0.0 FT (0.0 M)
(52) DECK WIDTH:
(32) APPR. ROADWAY WIDTH:
(213) APPR. PAVEMENT WIDTH:
LEFT SHOULDER:
RIGHT SHOULDER:
(33) BRIDGE MEDIAN:
(34) SKEW ANGLE:
(35) DECK FLARE?:
(47) TOTAL HORIZ. CLEARANCE:
(50) SIDEWALKS:
LEFT :
RIGHT :
(214) BRIDGE RAIL TYPE:
RAIL CONFIGURATION:
MATERIAL:
DESIGN TYPE:
(215) BRIDGE RAIL HEIGHT:
(53) MIN. VRT. CLEAR. OVER DECK:
(54) MIN. VRT. UNDERCLEARANCE:
32.8 FT (10.0 M)
30.0 FT (9.1 M)
22.0 FT (6.7 M)
4.0 FT (1.2 M)
4.0 FT (1.2 M)
0 - NO MEDIAN
0 °
NO
26.0 FT (7.9 M)
2.3 FT (0.7 M)
2.4 FT (0.7 M)
2 - MOUNTED ON PARAPET
2 - CONCRETE/ALUMINUM
1 - CONTINUOUS RAIL
2.88 FT (0.88 M)
99.99 FT (99.99 M)
27.25 FT (8.31 M)
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
4 - Stable; action required to pro
2 - REHAB/RECONSTRUCTION
D - MINOR
$0
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
1984-JOINT REPAIR. 2010-APPROACHES REPAVED.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
http:80�00'02.80 http:37�11'36.50
APPENDIX STRUCTURE NO. 5140-040P
PHOTOGRAPHS STRUCTURE NO. 5140-040P
PHOTO #1 - LOOKING SOUTHBOUND TOWARD CUMBERLAND KNOB
FLOW
PHOTO #2 - WEST (UPSTREAM) SIDE
PHOTO #3 - GENERAL TOPSIDE VIEW
LOOKING SOUTH
PHOTO #4 - TYPICAL RUSTING OF SLIDING
PLATE JOINTS OVER PIERS; JOINT OVER
NORTH PIER SHOWN; ALSO NOTE TYPICAL
DEBRIS ACCUMULATION IN JOINTS
PHOTO #5 - EDGE SPALLING AND
TRANSVERSE CRACKING OF DECK HEADER
AND NORTH ABUTMENT BACKWALL; ALSO
NOTE TYPICAL LOOSE COMPRESSION SEALS
OVER ABUTMENTS AT AREAS OF EDGE
SPALLING
PHOTO #6 - CLOSE-UP OF PREVIOUS PHOTO
PHOTO #7 - TYPICAL LONGITUDINAL AND MAP
CRACKING OF WEARING SURFACE;
SOUTHBOUND LANE, NORTH SPAN SHOWN
PHOTO #8 - TYPICAL ACCUMULATION OF SOIL,
DEBRIS, VEGETATION, AND MOSS GROWTH
ALONG CURBLINES AND SIDEWALKS; EAST
SIDEWALK SHOWN; ALSO NOTE TYPICAL
DRAIN FILLED WITH DEBRIS AND VEGETATION
PHOTO #9 - GENERAL UNDERSIDE VIEW LOOKING SOUTH, NORTH
SPAN
PHOTO #10 - TYPICAL STAINING AND LEAKAGE ON BOTTOM FLANGE
OF GIRDER #1 IN NORTH AND CENTER SPANS BELOW DECK DRAINS;
NORTH SPAN NEAR NORTH PIER SHOWN
PHOTO #11 - SPALL WITH EXPOSED REBAR ON UNDERSIDE OF GIRDER
#1 AT SOUTH ABUTMENT; ALSO NOTE TYPICAL RUSTING OF BEARING
SOLE PLATES
PHOTO #12 - GENERAL VIEW OF SOUTH ABUTMENT
PHOTO #13 - EROSION OF NORTH ABUTMENT SLOPE
PHOTO #14 - TWO MINOR SPALLS ON NORTH ABUTMENT BREASTWALL
PHOTO #15 - TYPICAL VERTICAL CRACKING OF
ABUTMENT BREASTWALLS; NORTH
ABUTMENT BELOW GIRDER #2 SHOWN
PHOTO #16 - GENERAL VIEW OF SOUTH PIER,
SOUTH SIDE; NOTE VINE GROWTH
PHOTO #17 - WEST COLUMN FOOTING EXPOSED AT NORTH PIER AT
SOUTHEAST CORNER
PHOTO #18 - UPSTREAM CHANNEL
PHOTO #19 - DOWNSTREAM CHANNEL