Bridge_Inspection_Rpt_STR_5140-039P.pdf

PDF 1 MB Posted

Attached to
Blue Ridge Parkway Preservation Federal contract opportunity
Solicitation number
DTFH71-17-R-00003
Issued by
Department of Transportation Federal Highway Administration

About this file

Bridge Inspection Rpt_STR#5140-039P

View the file

Other files for this federal contract opportunity

Other files attached to Blue Ridge Parkway Preservation, newest first.
File Type Posted
DTFH71-17-R-00003-Amend_0001.pdf PDF
Bridge_Inspection_Rpt_STR_5140-037P.pdf PDF
Subcontracting_plan.doc DOC document
ADV_Offeror's_Qualifications_Form_-_NP-BLRI_PV_PRES_FY16.doc DOC document
Plans_-_NP-BLRI_PV_PRES_FY16.pdf PDF
Bridge_Inspection_Rpt_STR_5140-054P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-041P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-048P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-053P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-018P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-042P.pdf PDF
VETS-4212.pdf PDF
Bridge_Inspection_Rpt_STR_5140-047P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-165P.pdf PDF
RFP_Solicitation_-_NP-BLRI_PV_PRES_FY16.pdf PDF
Bridge_Inspection_Rpt_STR_5140-043P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-040P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-049P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-038P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-044P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-017P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-046P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-052P.pdf PDF
FP14_Eng.pdf PDF
Bridge_Inspection_Rpt_STR_5140-019P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-051P.pdf PDF
Report_NEPA.pdf PDF
Bridge_Inspection_Rpt_STR_5140-050P.pdf PDF
Bridge_Inspection_Rpt_STR_5140-045P.pdf PDF
Synopsis_NP-BLRI_PV_PRES_FY16-Rev.pdf PDF
Synopsis_NP-BLRI_PV_PRES_FY16.pdf PDF
Show all 31

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BRIDGE INSPECTION REPORT

VA ROUTE 615 BRIDGE

BLUE RIDGE PARKWAY OVER N&W RR AND VA ROUTE 615

BLUE RIDGE PARKWAY

LN

STRUCTURE NO. 5140-039P

INSPECTION TYPE: ROUTINE

INSPECTION DATE: 10/28/14

Report prepared by: WS

MILE POINT: 124.07

Federal Highway Administration KILOMETER POINT: 199.81 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov

STRUCTURE SUMMARY STRUCTURE NO. 5140-039P

VA ROUTE 615 BRIDGE INSPECTION DATE: 10/28/14

BRIDGE IDENTIFICATION AND DESCRIPTION

MAIN SPAN MATERIAL: ....... PRESTRESSED CONCRETE NO. OF MAIN SPANS:

MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:

# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: ..

DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH:

WEARING SURFACE: .......... BITUMINOUS DECK W IDTH:

ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB W IDTH:

PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:

ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: ..

PROJ./PLAN REF. NO: ......... 1N6,7 / 3027 SKEW ANGLE:

NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL:

STRUCTURE HISTORY: ...... 1984,2008-JOINT REPAIR. 2010-REPAVED.

LOCATION

212.1 FT (64.6 M)

72.0 FT (21.9 M)

33.0 FT (10.1 M)

26.0 FT (7.9 M)

N/A

29 °

NO

BLUE RIDGE PARKWAY MILE POINT: ..................... 124.07 (KM PT 199.81)

STATE: ................................. VIRGINIA LOCATION: 0.2 MILES TO VA ROUTE 613

FACILITY CARRIED: ............ BLUE RIDGE PARKWAY

FEATURE INTERSECTED: .. N&W RR AND VA ROUTE 615

STRUCTURE EVALUATION SUMMARY

This prestressed concrete multi-girder bridge is in good condition overall. Though not observed during this inspection, there is heavy leakage through the deck expansion joints as evident by heavy moisture staining on the superstructure and substructure components below. Additionally the deck drains are too short which is also contributing to the moisture staining on the superstructure and substructure due to the drain proximity to the piers.

Other problems include full expansion of the center span bearings at the south pier, tree limbs overhanging the northeast parapet end, minor erosion of the south abutment slope under the deck drains on both sides of the structure, moderate vine growth on the west deck overhang and throughout the substructure components, and debris accumulation in the sliding plate joints.

Repairs should be made as outlined in this report to prevent the possible development of more serious or costly problems in the future.

INSPECTION TEAM: E.A. JARRELL, J.W . ELLENOR (CLARK NEXSEN)

CONDITION ASSESSMENT:

E. ALEX JARRELL, FIELD TEAM LEADER

REPORT REVIEW :

GARY J. GOODLIN, FIELD TEAM LEADER 703-404-6253

REPORT APPROVAL: DATE: 3/31/15

JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244

RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-039P

A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.

B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.

C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.

D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.

E (Special) - Structure is under construction or reconstruction.

D226 PRIORITY OF IMPROVEMENT

ITEM

NO.

MAINTENANCE RECOMMENDATIONS

(GENERALLY NOT FLHP ELIGIBLE)

QTY. UNIT COST

UNIT

ESTIMATE

COST

PRELIM.

58.7 EXTEND DECK DRAINS BEYOND GIRDER BOTTOM FLANGES. 1 LS

58.6 REMOVE TREE LIMBS OVERHANGING NORTHEAST PARAPET END. REMOVE VINE

GROWTH FROM DECK OVERHANGS AND SUBSTRUCTURE.

1 LS

60.9 STABILIZE EROSION OF SOUTH ABUTMENT SLOPE WITH ENGINEERED RIPRAP. 2 CY

PRELIM. MAINTENANCE TOTAL :

ITEM

NO.

REHABILITATION/RECONSTRUCTION

(TYPICALLY NEEDED WITHIN 5 YEARS)

QTY. UNIT

UNIT

COST ESTIMATES

PRELIM. COST

REHAB. RECONSTR.

58.2 CLEAN AND RESEAL DECK EXPANSION JOINTS. 1 LS $0

59.1 RESET CENTER SPAN BEARINGS AT SOUTH PIER. 1 LS $0

PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : $0

COST ESTIMATE SUMMARY

PRELIM. MAINTENANCE TOTAL:

PRELIM. REHABILITATION TOTAL:

PRELIMINARY ESTIMATE TOTAL* :

(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)

REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.

FIELD INSPECTION REPORT STRUCTURE NO. 5140-039P

G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)

CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS

SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.

Fatigue cracks in steel or shear cracks in concrete may be present.

CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.

“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.

FAILED CONDITION - out of service; beyond corrective action.

CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223

NOT APPLICABLE

EXCELLENT CONDITION

VERY GOOD CONDITION - no problems noted.

GOOD CONDITION - some minor problems.

SATISFACTORY CONDITION - structural elements show some minor deterioration.

FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.

POOR CONDITION - advanced section loss, deterioration, spalling, or scour.

N

58. DECK ITEM REFERENCE AND REMARKS

OTHER

ALIGNMENT

DEFLECTION AND/OR VIBRATION

FASCIA(E)

DIAPHRAGMS AND BRACING

TRUSSES

FLOOR BEAMS AND STRINGERS

ARCH(ES) OR SLAB(S)

GIRDERS OR BEAMS

BEARING DEVICES

59. SUPERSTRUCTURE

OTHER

DEFLECTION AND/OR VIBRATION

UTILITIES

DRAINS AND DRAINAGE

PARAPETS AND/OR RAILINGS

CURBS, SIDEWALKS, AND MEDIAN

RIDEABILITY

WEARING SURFACE

EXPANSION JOINTS

DECK SLAB

OTHER

SETTLEMENT OR DEFLECTION

EROSION AND/OR SCOUR

FOUNDATIONS

CAPS AND/OR BEARING SEATS

PILE BENTS

WALLS AND/OR COLUMNS

PIER(S)

OTHER

SLOPE PROTECTION

SETTLEMENT OR DEFLECTION

EROSION AND/OR SCOUR

EXPANSION JOINTS

WEEP HOLES

WINGWALLS

FOUNDATIONS

BACKWALLS AND/OR BULKHEADS

CAPS AND/OR BEARING SEATS

PILE BENTS

BREASTWALLS OR COLUMNS

ABUTMENTS

60. SUBSTRUCTURE

1.

10.

2.

3.

4.

5.

6.

7.

8.

9.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

PAINT

11.

G G N N N G N N G

N G

F N G G N G G N G G N N

G N G N G G N

11.

10.

9.

8.

7.

6.

5.

4.

3.

2.

1.

12.

13.

14.

15.

16.

17.

18.

19.

58.1 EXPOSED AND RUSTED REBAR CHAIRS ON DECK UNDERSIDE.

MINOR CRACKING WITH EFFLORESCENCE ON UNDERSIDE OF

OVERHANGS AT NORTH ABUTMENT AND PIERS. MINOR VINE

GROWTH ON WEST OVERHANG AT ENDS, NORTH AND SOUTH

SPANS.

58.1,2, 60.4 MINOR EDGE SPALLING AND TRANSVERSE CRACKING OF DECK

HEADERS AND NORTH ABUTMENT BACKWALL AT EXPANSION

JOINTS.

58.2 LOOSE COMPRESSION SEALS OVER ABUTMENTS AT AREAS OF

EDGE SPALLING. MODERATE GRAVEL ACCUMULATION IN JOINTS.

MINOR RUSTING OF SLIDING PLATE JOINTS OVER PIERS.

58.2, 59, 60 HEAVY STAINING ON SUPERSTRUCTURE AND SUBSTRUCTURE

COMPONENTS UNDER EXPANSION JOINTS INDICATING LEAKAGE

THROUGH JOINTS.

58.5 MINOR VERTICAL AND MAP CRACKING OF CURBS. MINOR SPALLING

OF WEST CURB AT SOUTH SLIDING PLATE JOINT.

58.6 MINOR VERTICAL CRACKING OF PARAPETS AT ISOLATED

LOCATIONS. TREES OVERHANGING NORTHEAST PARAPET END.

SEVERAL AREAS OF EXPOSED REBAR DUE TO INSUFFICIENT

CONCRETE COVER ON SOUTHWEST PARAPET.

58.7 LIGHT MOSS GROWTH ON SIDEWALKS ALONG PARAPETS. DECK

DRAINS DO NOT EXTEND PAST GIRDERS; SEVERAL DRAINS NEAR

PIER BEARINGS; SEE ALSO 59.2,6.

58.8 FIBER OPTIC LINES ALONG RAILROAD UNDER CENTER SPAN.

59.1 MINOR SURFACE RUSTING OF BEARINGS THROUGHOUT, PRIMARILY

ON ANCHOR BOLTS AND SOLE PLATES. CENTER SPAN BEARINGS

AT SOUTH PIER UP TO FULLY CONTRACTED AT 65°F.

59.2,6 MODERATE STAINING OF GIRDERS BELOW DECK DRAINS. MINOR

EFFLORESCENCE ON GIRDERS #1 AND #4 IN CENTER SPAN AT

SOUTH PIER. MINOR VERTICAL CRACKING OF END DIAPHRAGMS AT

ISOLATED LOCATIONS.

G G G G G G

N

F

G

G

INSPECTION DATE: 10/28/14

STRUCTURE NO. 5140-039P FIELD INSPECTION REPORT

VA ROUTE 615 BRIDGE

ITEM REFERENCE AND REMARKS

AVERAGE CLEAR OPENING 8.

NORMAL VELOCITY 7.

ADEQUACY OF OPENING 6.

OTHER 5.

WATERWAY OBSTRUCTIONS 4.

CHANNEL PROTECTION 3.

EROSION AND/OR SCOUR 2.

1. ALIGNMENT

61. CHANNEL N

9. STREAM BED COMPOSITION :

222. APPROACHES 8

OTHER 9.

ALIGNMENT 8.

SIGNS 7.

SETTLEMENT 6.

EROSION 5.

SURFACING 4.

APPROACH GUARDRAIL 3.

RELIEF JOINTS 2.

1. APPROACH SLABS N

N N G G G N G N

223. RETAINING WALL N

OTHER 6.

SETTLEMENT OR DEFLECTION 5.

EROSION AND/OR SCOUR 4.

FOUNDATION 3.

WEEP HOLES 2.

1. WALL

36. TRAFFIC AND SAFETY FEATURES

APPROACH GUARDRAIL ENDS D.

APPROACH GUARDRAILS C.

TRANSITIONS B.

BRIDGE RAILINGSA. 1

N N N

60.1 MINOR FULL HEIGHT VERTICAL CRACKING WITH MINOR TO

MODERATE EFFLORESCENCE ON BREASTWALLS. MINOR SPALLING

WITH EXPOSED REBAR ON SOUTH BREASTWALL. MINOR MAP

CRACKING WITH EFFLORESCENCE NEAR EAST SIDE OF SOUTH

ABUTMENT BREASTWALL; MINOR VINE GROWTH NEAR WEST SIDE,

60.3 MINOR TO MODERATE STAINING ON BEARING SEATS; MINOR

ACCUMULATION OF DEBRIS.

60.6 MINOR RANDOM CRACKING WITH EFFLORESCENCE ON

WINGWALLS; MINOR POPOUTS. MINOR VINE GROWTH ON

SOUTHWEST WINGWALL.

60.7 MINOR LOSS OF GRAVEL THROUGH NORTH ABUTMENT WEEP

HOLES.

60.9 MINOR EROSION (UP TO 1' DEEP) OF SOUTH ABUTMENT SLOPE

UNDER DECK DRAINS, BOTH SIDES OF STRUCTURE.

60.15 MINOR HORIZONTAL AND VERTICAL CRACKING ON SOUTH FACE OF

SOUTH PIER BELOW EXTERIOR BAYS; MINOR SCALING IN SOME

AREAS. NUMEROUS EXPOSED AND RUSTED FORM TIES ON

UNDERSIDE OF SOUTH PIER CAP.

TRAFFIC SAFETY RATING CODES

N

Does not meet standards or a safety feature is required and none is provided.

Meets currently acceptable standards.

Not applicable or a safety feature is not required.

STRUCTURE LOAD RATING STRUCTURE NO. 5140-039P

TRUCK TYPE

INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)

TONS METRIC TONS TONS METRIC TONS

H 15 14 25 23

HS 19 17 32 29

TYPE 3 18 16 31 28

TYPE 3S2 24 22 40 36

TYPE 3-3 29 26 48 44

DESIGN LOADING: H15 (M13.5)

X CAPACITY MEETS OR EXCEEDS DESIGN LOAD

CAPACITY IS LESS THAN DESIGN LOAD

ORIGINAL LOAD RATING CALCULATION APPLICABLE

ORIGINAL LOAD RATING CALCULATION REVISED

DATE OF LOAD RATING CALCULATION:

LOAD RATING CONTROLLED BY:

REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-039P

STRUCTURE IDENTIFICATION

(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 513 - VIRGINIA (VA)

(202) STRUCTURE NAME: .......... VA ROUTE 615 BRIDGE (2) STATE HWY. AGENCY DIST:

(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 161 - ROANOKE

(204) STRUCTURE NUMBER: ..... 5140-039P (4) CITY/PLACE CODE:

(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:

(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... N&W RR AND VA ROUTE 615

(207) ROAD SECTION NO: .......... 039P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY

(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140039P0000000

(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 0.2 MILES TO VA ROUTE 613

(210) OPERATING UNIT: ............. ROANOKE (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)

(211) PROJECT NO(S): ................ 1N6,7 (11) MILE POINT: ............................. 124.07 (KM PT 199.81)

(212) DRAWING NUMBERS: ....... 3027 (27) YEAR BUILT:

(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A

(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD

(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE

STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE

(43A) MAIN STR. MATERIAL: ..

(43B) MAIN STR. TYPE:

(45) NO. OF MAIN SPANS:

(48) MAX. SPAN LENGTH:

(49) STRUCTURE LENGTH:

(216A) ABUTMENT #1 FDN:

(216B) ABUTMENT #2 FDN:

(217A) PREDOM. PIER FDN.: ..

(217B) SECOND. PIER FDN: ...

(107) DECK TYPE:

5 - PRESTRESSED CONCRETE

02 - STRINGER/MULTI-BEAM or GIRDER

72.0 FT (21.9 M)

212.1 FT (64.6 M)

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

2 - SPREAD FTG ON BEARING MAT'L

1 - CONCRETE CAST-IN-PLACE

(44A) APPR. STR. MATERIAL: ........ 0 - OTHER

(44B) APPR. STR. TYPE: ................ 00 - OTHER

(46) NO. OF APPROACH SPANS: .. 0

(108) WEAR SURFACE/PROTECT SYSTEM:

A) TYPE WEARING SURFACE: .. 6 - BITUMINOUS

B) TYPE MEMBRANE: ................. 9 - OTHER

C) TYPE PROTECTION: .............. 0 - NONE

(218) IS SALT USED?: ..................... YES

LOAD RATING AND POSTING

(31) DESIGN LOAD: ................. 2 - H15 (M13.5) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION

(66) INVENTORY RATING: ...... 19.0 TONS (17.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED

(64) OPERATING RATING: ...... 32.0 TONS (29.0 METRIC TONS)

INSPECTION DATES

(90) INSPECTION DATE: 10/14 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):

(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO

INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE

(B) UNDERWATER: .............. NO

(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :

(C) SPECIAL INSPECTION: .. NO

INSP. EVERY: MONTHS - LAST INSP. :

STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-039P

GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA

(51) CURB TO CURB WIDTH: ........... 26.0 FT (7.9 M)

(16) LATITUDE: ............................. 37°11'28.00"

(17) LONGITUDE: ......................... 79°59'48.50"

(19) DETOUR LENGTH: ............... 26 MI (42 KM)

(28A) LANES ON STRUCT:

(28B) LANES UNDER STRUCT: ... 02

(42A) SERVICE ON: ..................... 5 - HIGHWAY-PEDESTRIAN

(42B) SERVICE UNDER: .............. 4 - HIGHWAY-RAILROAD

(29) AVG. DAILY TRAFFIC:

(30) YEAR OF ADT:

(114) FUTURE ADT:

(115) YEAR OF FUTURE ADT:

(101) PARALLEL STRUCTURE: ... N - NONE

(38) NAVIGATION CONTROL?: ... N

(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)

(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)

(111) ABUT. OR PIER PROT:

LATERAL UNDERCLEARANCE:

(55) RIGHT: ....................... 2.5 FT (0.8 M)

(56) LEFT: ......................... 0.0 FT (0.0 M)

CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST

(58) DECK:

(59) SUPERSTRUCTURE:

(60) SUBSTRUCTURE:

(61) CHANNEL: .......................... N

(62) CULVERT: ........................... N

(222) APPROACHES:

(223) RETAINING WALL: ........... N

(36) TRAFFIC SAFETY FEAT: ... 1NNN

(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB

(75B) WORK DONE BY: ............. 1 - CONTRACT

(76) IMPROVEMENT LENGTH: .. 1.0 FT (0.3 M)

(52) DECK WIDTH:

(32) APPR. ROADWAY WIDTH:

(213) APPR. PAVEMENT WIDTH:

LEFT SHOULDER:

RIGHT SHOULDER:

(33) BRIDGE MEDIAN:

(34) SKEW ANGLE:

(35) DECK FLARE?:

(47) TOTAL HORIZ. CLEARANCE:

(50) SIDEWALKS:

LEFT :

RIGHT :

(214) BRIDGE RAIL TYPE:

RAIL CONFIGURATION:

MATERIAL:

DESIGN TYPE:

(215) BRIDGE RAIL HEIGHT:

(53) MIN. VRT. CLEAR. OVER DECK:

(54) MIN. VRT. UNDERCLEARANCE:

33.0 FT (10.1 M)

30.0 FT (9.1 M)

22.0 FT (6.7 M)

4.0 FT (1.2 M)

4.0 FT (1.2 M)

0 - NO MEDIAN

29 °

NO

26.0 FT (7.9 M)

2.5 FT (0.8 M)

2.5 FT (0.8 M)

2 - MOUNTED ON PARAPET

2 - CONCRETE/ALUMINUM

1 - CONTINUOUS RAIL

2.75 FT (0.84 M)

99.99 FT (99.99 M)

19.83 FT (6.04 M)

(67) STRUCTURAL EVALUATION:

(68) DECK GEOMETRY:

(69) UNDERCLEARANCES:

(71) WATERWAY ADEQUACY:

(72) APPROACH ALIGNMENT:

(113) SCOUR CRITICAL:

(225) PURPOSE OF IMPROVEMENT:

(226) PRIORITY OF IMPROVEMENT:

(227) MAINTENANCE COST:

(228) REHAB./RECONSTR. COST: ...

(229) CONSTRUCTION COST:

N

N - Not over waterway.

2 - REHAB/RECONSTRUCTION

D - MINOR

$0

ADDITIONAL INFORMATION

(230) STRUCTURE HISTORY:

1984,2008-JOINT REPAIR. 2010-REPAVED.

(231) ADDITIONAL CONSIDERATIONS:

(330) ADDITIONAL CONFIG. INFO.:

http:79�59'48.50 http:37�11'28.00

APPENDIX STRUCTURE NO. 5140-039P

PHOTOGRAPHS STRUCTURE NO. 5140-039P

PHOTO #1 - LOOKING SOUTHBOUND TOWARD CUMBERLAND KNOB

PHOTO #2 - EAST SIDE

PHOTO #3 - GENERAL TOPSIDE VIEW LOOKING SOUTH

PHOTO #4 - TREES OVERHANGING NORTHEAST PARAPET END

PHOTO #5 - EDGE SPALLING AND

TRANSVERSE CRACKING OF NORTH

ABUTMENT BACKWALL AND DECK HEADER;

ALSO NOTE TYPICAL LOOSE COMPRESSION

SEAL AT AREAS OF EDGE SPALLING

PHOTO #6 - CLOSE-UP OF PREVIOUS PHOTO

PHOTO #7 - TYPICAL GRAVEL ACCUMULATION

IN JOINTS; JOINT OVER NORTH PIER SHOWN;

ALSO NOTE TYPICAL RUSTING OF SLIDING

PLATE JOINTS

PHOTO #8 - SPALLING OF WEST CURB AT

SOUTH SLIDING PLATE JOINT; ALSO NOTE

TYPICAL RUSTING OF SLIDING PLATE JOINTS

PHOTO #9 - GENERAL UNDERSIDE VIEW LOOKING NORTH, CENTER

SPAN

PHOTO #10 - TYPICAL STAINING ON SUPERSTRUCTURE; EAST SIDE OF

GIRDER #1 IN SPAN #1 SHOWN; ALSO NOTE TYPICAL SHORT DECK

DRAIN

PHOTO #11 - TYPICAL CENTER SPAN BEARINGS AT SOUTH PIER UP TO

FULLY CONTRACTED; GIRDER #2 SHOWN; ALSO NOTE TYPICAL

RUSTING OF BEARINGS

PHOTO #12 - GENERAL VIEW OF NORTH ABUTMENT

PHOTO #13 - TYPICAL SPALLING WITH EXPOSED REBAR ON SOUTH

BREASTWALL; AT TOP BETWEEN GIRDER #2 AND #3 SHOWN

PHOTO #14 - VINE GROWTH NEAR WEST SIDE OF SOUTH ABUTMENT

BREASTWALL; ALSO NOTE TYPICAL STAINING ON SUBSTRUCTURE

PHOTO #15 - TYPICAL EROSION OF SOUTH

ABUTMENT SLOPE UNDER DECK DRAINS;

EAST SIDE SHOWN

PHOTO #16 - GENERAL VIEW OF NORTH PIER,

NORTH SIDE; NOTE TYPICAL STAINING

PHOTO #17 - TYPICAL EXPOSED AND RUSTED FORM TIES ON

UNDERSIDE OF SOUTH PIER CAP; BETWEEN EAST AND WEST

COLUMNS SHOWN