BRIDGE INSPECTION REPORT
VA ROUTE 615 BRIDGE
BLUE RIDGE PARKWAY OVER N&W RR AND VA ROUTE 615
BLUE RIDGE PARKWAY
LN
STRUCTURE NO. 5140-039P
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 10/28/14
Report prepared by: WS
MILE POINT: 124.07
Federal Highway Administration KILOMETER POINT: 199.81 Federal Lands Bridge Office Bridge Inspection and Management Program 21400 Ridgetop Circle Sterling, Virginia 20166 https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 5140-039P
VA ROUTE 615 BRIDGE INSPECTION DATE: 10/28/14
BRIDGE IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ....... PRESTRESSED CONCRETE NO. OF MAIN SPANS:
MAIN SPAN TYPE: ............... STRINGER/MULTI-BEAM or GIRDER NO. OF APPR. SPANS:
# OF BEAMS, MAIN SPAN: .. 4 STRUCT. TOTAL LENGTH: ..
DECK TYPE: ......................... CONCRETE CAST-IN-PLACE MAX. SPAN LENGTH:
WEARING SURFACE: .......... BITUMINOUS DECK W IDTH:
ABUT. FOUNDATIONS: ........ SPREAD FTG ON BEARING MAT'L CURB TO CURB W IDTH:
PIER FOUNDATION(S): ........ SPREAD FTG ON BEARING MAT'L YEAR BUILT:
ABUTMENT / PIER MAT'L: ... CONCRETE YEAR RECONSTRUCTED: ..
PROJ./PLAN REF. NO: ......... 1N6,7 / 3027 SKEW ANGLE:
NPS ROAD CLASS: .............. 1 - PRINCIPAL PARK ROAD FRACTURE CRITICAL:
STRUCTURE HISTORY: ...... 1984,2008-JOINT REPAIR. 2010-REPAVED.
LOCATION
212.1 FT (64.6 M)
72.0 FT (21.9 M)
33.0 FT (10.1 M)
26.0 FT (7.9 M)
N/A
29 °
NO
BLUE RIDGE PARKWAY MILE POINT: ..................... 124.07 (KM PT 199.81)
STATE: ................................. VIRGINIA LOCATION: 0.2 MILES TO VA ROUTE 613
FACILITY CARRIED: ............ BLUE RIDGE PARKWAY
FEATURE INTERSECTED: .. N&W RR AND VA ROUTE 615
STRUCTURE EVALUATION SUMMARY
This prestressed concrete multi-girder bridge is in good condition overall. Though not observed during this inspection, there is heavy leakage through the deck expansion joints as evident by heavy moisture staining on the superstructure and substructure components below. Additionally the deck drains are too short which is also contributing to the moisture staining on the superstructure and substructure due to the drain proximity to the piers.
Other problems include full expansion of the center span bearings at the south pier, tree limbs overhanging the northeast parapet end, minor erosion of the south abutment slope under the deck drains on both sides of the structure, moderate vine growth on the west deck overhang and throughout the substructure components, and debris accumulation in the sliding plate joints.
Repairs should be made as outlined in this report to prevent the possible development of more serious or costly problems in the future.
INSPECTION TEAM: E.A. JARRELL, J.W . ELLENOR (CLARK NEXSEN)
CONDITION ASSESSMENT:
E. ALEX JARRELL, FIELD TEAM LEADER
REPORT REVIEW :
GARY J. GOODLIN, FIELD TEAM LEADER 703-404-6253
REPORT APPROVAL: DATE: 3/31/15
JORGOMAI CEESAY, PH.D., P.E., BIP SUPERVISORY ENGINEER 703-404-6244
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 5140-039P
A (Critical) - Structure is closed, in imminent danger of collapse, or presents a critical safety hazard.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain in service at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventative maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
D226 PRIORITY OF IMPROVEMENT
ITEM
NO.
MAINTENANCE RECOMMENDATIONS
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT COST
UNIT
ESTIMATE
COST
PRELIM.
58.7 EXTEND DECK DRAINS BEYOND GIRDER BOTTOM FLANGES. 1 LS
58.6 REMOVE TREE LIMBS OVERHANGING NORTHEAST PARAPET END. REMOVE VINE
GROWTH FROM DECK OVERHANGS AND SUBSTRUCTURE.
1 LS
60.9 STABILIZE EROSION OF SOUTH ABUTMENT SLOPE WITH ENGINEERED RIPRAP. 2 CY
PRELIM. MAINTENANCE TOTAL :
ITEM
NO.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST ESTIMATES
PRELIM. COST
REHAB. RECONSTR.
58.2 CLEAN AND RESEAL DECK EXPANSION JOINTS. 1 LS $0
59.1 RESET CENTER SPAN BEARINGS AT SOUTH PIER. 1 LS $0
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : $0
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL:
PRELIM. REHABILITATION TOTAL:
PRELIMINARY ESTIMATE TOTAL* :
(*Includes typical contract costs for mobilization, traffic control, and design/construction engineering; but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for preliminary planning purposes only; they should not be used as a complete or final engineers estimate.)
REMARKS: Cost estimates assume that recommended actions will be combined with similar work being performed on other structures.
FIELD INSPECTION REPORT STRUCTURE NO. 5140-039P
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible.
Fatigue cracks in steel or shear cracks in concrete may be present.
CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
“IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical structural components or obvious vertical or horizontal movement affecting structure stability. Structure is closed to traffic but corrective action may return structure to light service.
FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
NOT APPLICABLE
EXCELLENT CONDITION
VERY GOOD CONDITION - no problems noted.
GOOD CONDITION - some minor problems.
SATISFACTORY CONDITION - structural elements show some minor deterioration.
FAIR CONDITION - all primary structural elements are sound but may have minor section loss, cracking, spalling, or scour.
POOR CONDITION - advanced section loss, deterioration, spalling, or scour.
N
58. DECK ITEM REFERENCE AND REMARKS
OTHER
ALIGNMENT
DEFLECTION AND/OR VIBRATION
FASCIA(E)
DIAPHRAGMS AND BRACING
TRUSSES
FLOOR BEAMS AND STRINGERS
ARCH(ES) OR SLAB(S)
GIRDERS OR BEAMS
BEARING DEVICES
59. SUPERSTRUCTURE
OTHER
DEFLECTION AND/OR VIBRATION
UTILITIES
DRAINS AND DRAINAGE
PARAPETS AND/OR RAILINGS
CURBS, SIDEWALKS, AND MEDIAN
RIDEABILITY
WEARING SURFACE
EXPANSION JOINTS
DECK SLAB
OTHER
SETTLEMENT OR DEFLECTION
EROSION AND/OR SCOUR
FOUNDATIONS
CAPS AND/OR BEARING SEATS
PILE BENTS
WALLS AND/OR COLUMNS
PIER(S)
OTHER
SLOPE PROTECTION
SETTLEMENT OR DEFLECTION
EROSION AND/OR SCOUR
EXPANSION JOINTS
WEEP HOLES
WINGWALLS
FOUNDATIONS
BACKWALLS AND/OR BULKHEADS
CAPS AND/OR BEARING SEATS
PILE BENTS
BREASTWALLS OR COLUMNS
ABUTMENTS
60. SUBSTRUCTURE
1.
10.
2.
3.
4.
5.
6.
7.
8.
9.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
PAINT
11.
G G N N N G N N G
N G
F N G G N G G N G G N N
G N G N G G N
11.
10.
9.
8.
7.
6.
5.
4.
3.
2.
1.
12.
13.
14.
15.
16.
17.
18.
19.
58.1 EXPOSED AND RUSTED REBAR CHAIRS ON DECK UNDERSIDE.
MINOR CRACKING WITH EFFLORESCENCE ON UNDERSIDE OF
OVERHANGS AT NORTH ABUTMENT AND PIERS. MINOR VINE
GROWTH ON WEST OVERHANG AT ENDS, NORTH AND SOUTH
SPANS.
58.1,2, 60.4 MINOR EDGE SPALLING AND TRANSVERSE CRACKING OF DECK
HEADERS AND NORTH ABUTMENT BACKWALL AT EXPANSION
JOINTS.
58.2 LOOSE COMPRESSION SEALS OVER ABUTMENTS AT AREAS OF
EDGE SPALLING. MODERATE GRAVEL ACCUMULATION IN JOINTS.
MINOR RUSTING OF SLIDING PLATE JOINTS OVER PIERS.
58.2, 59, 60 HEAVY STAINING ON SUPERSTRUCTURE AND SUBSTRUCTURE
COMPONENTS UNDER EXPANSION JOINTS INDICATING LEAKAGE
THROUGH JOINTS.
58.5 MINOR VERTICAL AND MAP CRACKING OF CURBS. MINOR SPALLING
OF WEST CURB AT SOUTH SLIDING PLATE JOINT.
58.6 MINOR VERTICAL CRACKING OF PARAPETS AT ISOLATED
LOCATIONS. TREES OVERHANGING NORTHEAST PARAPET END.
SEVERAL AREAS OF EXPOSED REBAR DUE TO INSUFFICIENT
CONCRETE COVER ON SOUTHWEST PARAPET.
58.7 LIGHT MOSS GROWTH ON SIDEWALKS ALONG PARAPETS. DECK
DRAINS DO NOT EXTEND PAST GIRDERS; SEVERAL DRAINS NEAR
PIER BEARINGS; SEE ALSO 59.2,6.
58.8 FIBER OPTIC LINES ALONG RAILROAD UNDER CENTER SPAN.
59.1 MINOR SURFACE RUSTING OF BEARINGS THROUGHOUT, PRIMARILY
ON ANCHOR BOLTS AND SOLE PLATES. CENTER SPAN BEARINGS
AT SOUTH PIER UP TO FULLY CONTRACTED AT 65°F.
59.2,6 MODERATE STAINING OF GIRDERS BELOW DECK DRAINS. MINOR
EFFLORESCENCE ON GIRDERS #1 AND #4 IN CENTER SPAN AT
SOUTH PIER. MINOR VERTICAL CRACKING OF END DIAPHRAGMS AT
ISOLATED LOCATIONS.
G G G G G G
N
F
G
G
INSPECTION DATE: 10/28/14
STRUCTURE NO. 5140-039P FIELD INSPECTION REPORT
VA ROUTE 615 BRIDGE
ITEM REFERENCE AND REMARKS
AVERAGE CLEAR OPENING 8.
NORMAL VELOCITY 7.
ADEQUACY OF OPENING 6.
OTHER 5.
WATERWAY OBSTRUCTIONS 4.
CHANNEL PROTECTION 3.
EROSION AND/OR SCOUR 2.
1. ALIGNMENT
61. CHANNEL N
9. STREAM BED COMPOSITION :
222. APPROACHES 8
OTHER 9.
ALIGNMENT 8.
SIGNS 7.
SETTLEMENT 6.
EROSION 5.
SURFACING 4.
APPROACH GUARDRAIL 3.
RELIEF JOINTS 2.
1. APPROACH SLABS N
N N G G G N G N
223. RETAINING WALL N
OTHER 6.
SETTLEMENT OR DEFLECTION 5.
EROSION AND/OR SCOUR 4.
FOUNDATION 3.
WEEP HOLES 2.
1. WALL
36. TRAFFIC AND SAFETY FEATURES
APPROACH GUARDRAIL ENDS D.
APPROACH GUARDRAILS C.
TRANSITIONS B.
BRIDGE RAILINGSA. 1
N N N
60.1 MINOR FULL HEIGHT VERTICAL CRACKING WITH MINOR TO
MODERATE EFFLORESCENCE ON BREASTWALLS. MINOR SPALLING
WITH EXPOSED REBAR ON SOUTH BREASTWALL. MINOR MAP
CRACKING WITH EFFLORESCENCE NEAR EAST SIDE OF SOUTH
ABUTMENT BREASTWALL; MINOR VINE GROWTH NEAR WEST SIDE,
60.3 MINOR TO MODERATE STAINING ON BEARING SEATS; MINOR
ACCUMULATION OF DEBRIS.
60.6 MINOR RANDOM CRACKING WITH EFFLORESCENCE ON
WINGWALLS; MINOR POPOUTS. MINOR VINE GROWTH ON
SOUTHWEST WINGWALL.
60.7 MINOR LOSS OF GRAVEL THROUGH NORTH ABUTMENT WEEP
HOLES.
60.9 MINOR EROSION (UP TO 1' DEEP) OF SOUTH ABUTMENT SLOPE
UNDER DECK DRAINS, BOTH SIDES OF STRUCTURE.
60.15 MINOR HORIZONTAL AND VERTICAL CRACKING ON SOUTH FACE OF
SOUTH PIER BELOW EXTERIOR BAYS; MINOR SCALING IN SOME
AREAS. NUMEROUS EXPOSED AND RUSTED FORM TIES ON
UNDERSIDE OF SOUTH PIER CAP.
TRAFFIC SAFETY RATING CODES
N
Does not meet standards or a safety feature is required and none is provided.
Meets currently acceptable standards.
Not applicable or a safety feature is not required.
STRUCTURE LOAD RATING STRUCTURE NO. 5140-039P
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 15 14 25 23
HS 19 17 32 29
TYPE 3 18 16 31 28
TYPE 3S2 24 22 40 36
TYPE 3-3 29 26 48 44
DESIGN LOADING: H15 (M13.5)
X CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION:
LOAD RATING CONTROLLED BY:
REMARKS: RATING IS BASED ON DESIGN LOAD OF STRUCTURE.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-039P
STRUCTURE IDENTIFICATION
(201) PARK: BLUE RIDGE PARKWAY (1) STATE: ....................................... 513 - VIRGINIA (VA)
(202) STRUCTURE NAME: .......... VA ROUTE 615 BRIDGE (2) STATE HWY. AGENCY DIST:
(203) STRUCTURE KIND: ............ 1 - BRIDGE (3) COUNTY CODE: ........................ 161 - ROANOKE
(204) STRUCTURE NUMBER: ..... 5140-039P (4) CITY/PLACE CODE:
(205) NPS REGION: .................... 4 - SOUTHEAST (5) INVENTORY ROUTE:
(206) ROUTE CODE NUMBER: ... 1 (6) FEATURES INTERSECTED:....... N&W RR AND VA ROUTE 615
(207) ROAD SECTION NO: .......... 039P (7) FACILITY CARRIED: .................. BLUE RIDGE PARKWAY
(208) NPS ROAD CLASS: ............ 1 - PRINCIPAL PARK ROAD (8) STATE STRUCTURE NO: .......... 5140039P0000000
(209) WITHIN NPS BNDRY?: ....... YES (9) LOCATION: ................................ 0.2 MILES TO VA ROUTE 613
(210) OPERATING UNIT: ............. ROANOKE (10) INV. RTE. - MIN. VERT. CLR: .. 99.99 FT (99.99 M)
(211) PROJECT NO(S): ................ 1N6,7 (11) MILE POINT: ............................. 124.07 (KM PT 199.81)
(212) DRAWING NUMBERS: ....... 3027 (27) YEAR BUILT:
(21) MAINTAINED BY: ................. 66 - NATIONAL PARK SERVICE (106) YEAR RECONSTRUCTED: .... N/A
(22) OWNER: ............................... 66 - NATIONAL PARK SERVICE (20) TOLL: ........................................ 3 - FREE ROAD
(37) HISTORICAL DESIGNATION: .. 5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL: ..
(43B) MAIN STR. TYPE:
(45) NO. OF MAIN SPANS:
(48) MAX. SPAN LENGTH:
(49) STRUCTURE LENGTH:
(216A) ABUTMENT #1 FDN:
(216B) ABUTMENT #2 FDN:
(217A) PREDOM. PIER FDN.: ..
(217B) SECOND. PIER FDN: ...
(107) DECK TYPE:
5 - PRESTRESSED CONCRETE
02 - STRINGER/MULTI-BEAM or GIRDER
72.0 FT (21.9 M)
212.1 FT (64.6 M)
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
2 - SPREAD FTG ON BEARING MAT'L
1 - CONCRETE CAST-IN-PLACE
(44A) APPR. STR. MATERIAL: ........ 0 - OTHER
(44B) APPR. STR. TYPE: ................ 00 - OTHER
(46) NO. OF APPROACH SPANS: .. 0
(108) WEAR SURFACE/PROTECT SYSTEM:
A) TYPE WEARING SURFACE: .. 6 - BITUMINOUS
B) TYPE MEMBRANE: ................. 9 - OTHER
C) TYPE PROTECTION: .............. 0 - NONE
(218) IS SALT USED?: ..................... YES
LOAD RATING AND POSTING
(31) DESIGN LOAD: ................. 2 - H15 (M13.5) (41) LOAD RESTRICTION: ......... A - OPEN, NO RESTRICTION
(66) INVENTORY RATING: ...... 19.0 TONS (17.0 METRIC TONS) (70) BRIDGE POSTING: .............. 5 - NO POSTING REQUIRED
(64) OPERATING RATING: ...... 32.0 TONS (29.0 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 10/14 (91) FREQ. OF INSP: 24 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL: ... NO
INSP. EVERY: MONTHS - LAST INSP. : (220) SPECIAL STUDY TYPE: 0 - NONE
(B) UNDERWATER: .............. NO
(221) SPECIAL STUDY DATE: INSP. EVERY: MONTHS - LAST INSP. :
(C) SPECIAL INSPECTION: .. NO
INSP. EVERY: MONTHS - LAST INSP. :
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 5140-039P
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(51) CURB TO CURB WIDTH: ........... 26.0 FT (7.9 M)
(16) LATITUDE: ............................. 37°11'28.00"
(17) LONGITUDE: ......................... 79°59'48.50"
(19) DETOUR LENGTH: ............... 26 MI (42 KM)
(28A) LANES ON STRUCT:
(28B) LANES UNDER STRUCT: ... 02
(42A) SERVICE ON: ..................... 5 - HIGHWAY-PEDESTRIAN
(42B) SERVICE UNDER: .............. 4 - HIGHWAY-RAILROAD
(29) AVG. DAILY TRAFFIC:
(30) YEAR OF ADT:
(114) FUTURE ADT:
(115) YEAR OF FUTURE ADT:
(101) PARALLEL STRUCTURE: ... N - NONE
(38) NAVIGATION CONTROL?: ... N
(39) VERTICAL CLEARANCE: ...... 0.0 FT (0.0 M)
(40) HORIZ. CLEARANCE: ........... 0.0 FT (0.0 M)
(111) ABUT. OR PIER PROT:
LATERAL UNDERCLEARANCE:
(55) RIGHT: ....................... 2.5 FT (0.8 M)
(56) LEFT: ......................... 0.0 FT (0.0 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:
(59) SUPERSTRUCTURE:
(60) SUBSTRUCTURE:
(61) CHANNEL: .......................... N
(62) CULVERT: ........................... N
(222) APPROACHES:
(223) RETAINING WALL: ........... N
(36) TRAFFIC SAFETY FEAT: ... 1NNN
(75A) TYPE OF WORK: .............. 35 - GENERAL REHAB
(75B) WORK DONE BY: ............. 1 - CONTRACT
(76) IMPROVEMENT LENGTH: .. 1.0 FT (0.3 M)
(52) DECK WIDTH:
(32) APPR. ROADWAY WIDTH:
(213) APPR. PAVEMENT WIDTH:
LEFT SHOULDER:
RIGHT SHOULDER:
(33) BRIDGE MEDIAN:
(34) SKEW ANGLE:
(35) DECK FLARE?:
(47) TOTAL HORIZ. CLEARANCE:
(50) SIDEWALKS:
LEFT :
RIGHT :
(214) BRIDGE RAIL TYPE:
RAIL CONFIGURATION:
MATERIAL:
DESIGN TYPE:
(215) BRIDGE RAIL HEIGHT:
(53) MIN. VRT. CLEAR. OVER DECK:
(54) MIN. VRT. UNDERCLEARANCE:
33.0 FT (10.1 M)
30.0 FT (9.1 M)
22.0 FT (6.7 M)
4.0 FT (1.2 M)
4.0 FT (1.2 M)
0 - NO MEDIAN
29 °
NO
26.0 FT (7.9 M)
2.5 FT (0.8 M)
2.5 FT (0.8 M)
2 - MOUNTED ON PARAPET
2 - CONCRETE/ALUMINUM
1 - CONTINUOUS RAIL
2.75 FT (0.84 M)
99.99 FT (99.99 M)
19.83 FT (6.04 M)
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:
(225) PURPOSE OF IMPROVEMENT:
(226) PRIORITY OF IMPROVEMENT:
(227) MAINTENANCE COST:
(228) REHAB./RECONSTR. COST: ...
(229) CONSTRUCTION COST:
N
N - Not over waterway.
2 - REHAB/RECONSTRUCTION
D - MINOR
$0
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
1984,2008-JOINT REPAIR. 2010-REPAVED.
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIG. INFO.:
http:79�59'48.50 http:37�11'28.00
APPENDIX STRUCTURE NO. 5140-039P
PHOTOGRAPHS STRUCTURE NO. 5140-039P
PHOTO #1 - LOOKING SOUTHBOUND TOWARD CUMBERLAND KNOB
PHOTO #2 - EAST SIDE
PHOTO #3 - GENERAL TOPSIDE VIEW LOOKING SOUTH
PHOTO #4 - TREES OVERHANGING NORTHEAST PARAPET END
PHOTO #5 - EDGE SPALLING AND
TRANSVERSE CRACKING OF NORTH
ABUTMENT BACKWALL AND DECK HEADER;
ALSO NOTE TYPICAL LOOSE COMPRESSION
SEAL AT AREAS OF EDGE SPALLING
PHOTO #6 - CLOSE-UP OF PREVIOUS PHOTO
PHOTO #7 - TYPICAL GRAVEL ACCUMULATION
IN JOINTS; JOINT OVER NORTH PIER SHOWN;
ALSO NOTE TYPICAL RUSTING OF SLIDING
PLATE JOINTS
PHOTO #8 - SPALLING OF WEST CURB AT
SOUTH SLIDING PLATE JOINT; ALSO NOTE
TYPICAL RUSTING OF SLIDING PLATE JOINTS
PHOTO #9 - GENERAL UNDERSIDE VIEW LOOKING NORTH, CENTER
SPAN
PHOTO #10 - TYPICAL STAINING ON SUPERSTRUCTURE; EAST SIDE OF
GIRDER #1 IN SPAN #1 SHOWN; ALSO NOTE TYPICAL SHORT DECK
DRAIN
PHOTO #11 - TYPICAL CENTER SPAN BEARINGS AT SOUTH PIER UP TO
FULLY CONTRACTED; GIRDER #2 SHOWN; ALSO NOTE TYPICAL
RUSTING OF BEARINGS
PHOTO #12 - GENERAL VIEW OF NORTH ABUTMENT
PHOTO #13 - TYPICAL SPALLING WITH EXPOSED REBAR ON SOUTH
BREASTWALL; AT TOP BETWEEN GIRDER #2 AND #3 SHOWN
PHOTO #14 - VINE GROWTH NEAR WEST SIDE OF SOUTH ABUTMENT
BREASTWALL; ALSO NOTE TYPICAL STAINING ON SUBSTRUCTURE
PHOTO #15 - TYPICAL EROSION OF SOUTH
ABUTMENT SLOPE UNDER DECK DRAINS;
EAST SIDE SHOWN
PHOTO #16 - GENERAL VIEW OF NORTH PIER,
NORTH SIDE; NOTE TYPICAL STAINING
PHOTO #17 - TYPICAL EXPOSED AND RUSTED FORM TIES ON
UNDERSIDE OF SOUTH PIER CAP; BETWEEN EAST AND WEST
COLUMNS SHOWN
File details come from the government source that posted it. Updated .