This document contains details of a federal solicitation opportunity to correct deficiencies in Building 1 at the VA New Jersey Healthcare System located in Lyons, New Jersey. The contractor shall demolish existing structures, prepare the site for building operations, and furnish all labor and materials required to perform the work defined in the attached architecture and engineering drawings and specifications. The anticipated magnitude of construction is between $1 million and $5 million, with a completion time of 365 days from the notice to proceed date. This is a service-disabled veteran-owned small business set-aside procurement under North American Industry Classification System code 236220 with a business size standard of $39.5 million. A pre-bid walkthrough is scheduled for June 2, 2022 at 9:00 AM Eastern time. Interested parties should review the attached solicitation for additional requirement details. The soliciting agency is the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL NOTES:
1. EXISTING CONDITIONS HAVE BEEN SHOWN FROM GENERAL SPACE OBSERVATIONS AND EXISTING DRAWINGS.
RESPECTIVE TRADES SHALL CONDUCT A COMPLETE FIELD SURVEY OF EXISTING CONDITIONS PRIOR TO SUBMISSION OF BID PRICE. NO ADDITIONAL PAYMENT WILL BE MADE FOR CLAIMS THAT ARISE FROM LACK OF KNOWLEDGE OF
EXISTING CONDITIONS.
2. ALL FINISHES SHALL COMPLY WITH AND BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE LOCAL CODES AND
ORDINANCES; IBC SECTIONS 803, 804 AND 805.
3. THE CONTRACTOR SHALL GUARANTEE ALL WORK AND MATERIALS FOR A MINIMUM OF TWELVE (12) MONTHS AFTER THE DATE OF FINAL COMPLETION TO CONTRACTOR UNDER THE CONTRACT. ANY ITEMS DEEMED TO BE DEFECTIVE SHALL BE REPLACED AT CONTRACTORS SOLE EXPENSE, BUT AT OWNER'S OPTION AND CONVENIENCE, BE
REPAIRED, REPLACED OR RE-PERFORMED.
4. ALL GYPSUM BOARD SOFFITS AND HEADERS WITHIN THE SCOPE LIMIT LINES TO BE PAINTED SAME AS ADJACENT
WALL COLOR UNLESS NOTED OTHERWISE.
5. FINISH DRAWINGS SUPERSEDE ARCHITECTURAL DRAWINGS FOR FINISH MATERIALS, COLORS AND LOCATIONS ONLY.
6. FINISH SAMPLES SHALL BE SUBMITTED TO COR FOR APPROVAL BEFORE PURCHASING AND INSTALLATION.
7. FINAL COUNTERTOP GROMMET LOCATIONS TO BE FIELD VERIFIED.
FLOORING NOTES:
1. CONTRACTOR IS TO FIELD VERIFY ALL EXISTING CONDITIONS AND NOTIFY COR OF ANY DISCREPANCIES.
2. PROVIDE NEW RUBBER BASE AND FLOOR COVERINGS AS SPECIFIED THROUGHOUT. CONTRACTOR TO PREP FLOORS
AS NECESSARY FOR NEW FINISHES.
3. CONTRACTOR TO PROVIDE TEMPORARY PROTECTION ON ALL NEW FLOORING.
4. CONTRACTOR TO CLEAR CAULK AT ALL DOOR FRAMES WHERE NEW RESILIENT FLOORING HAS BEEN INSTALLED
WITHIN SCOPE LIMITS.
5. TRANSITION AND REDUCING STRIPS ARE TO BE INSTALLED AT ALL CHANGES IN FLOOR MATERIAL AND/OR ELEVATION THAT OCCURS IN AREAS TO BE NEWLY FINISHED. VERIFY WITH COR EACH CONDITION AND TYPE OF TRANSITION AND/OR REDUCING STRIP TO BE USED PRIOR TO INSTALLATION. FLOAT FLOOR AS REQUIRED FOR SMOOTH/FLUSH TRANSITION BETWEEN MATERIAL CHANGES. TRANSITION TO BE INSTALLED AT CENTER OF DOOR AND OPENINGS.
6. REFER TO DRAWING FOR FLOORING START LOCATIONS. DO NOT INSTALL TILE THAT IS 4" IN WIDTH, OR LESS.
WALL NOTES:
1. PREP WALLS FOR NEW FINISHES, PATCH AND REPAIR WALLS TO CREATE A SMOOTH UNIFORM FINISH.
2. CONTRACTOR TO APPLY AT LEAST TWO COATS OF PAINT. EACH COAT TO BE EQUAL TO 1.6 MIL. APPLY MORE IF
NECESSARY TO COVER EXISTING COLOR.
3. CONTRACTOR IS TO PREP WALLS AS NECESSARY FOR NEW WALL BASE.
4. CONTRACTOR SHALL PAINT ALL MISC. METAL ITEMS SUCH AS ELECTRICAL PANEL COVERS, COUNTERTOP SUPPORT BRACKERTS, ELECTRICAL WIRE MOLD, ETC. TO MATCH ADJACENT WALL COLOR. SEE WALL FINISH SCHEDULE.
METAL FLOORING TRANSITION-
SIZED PER FLOORING MATERIAL
THICKNESS (TRAN-1)
EXISTING VCT
NEW RUBBER TILE (RT-1)
ALIGN NEW FLOORING
TRANSITION WITH
CENTERLINE OF EXISITNG
DOOR FRAME (TRAN-1)
EXISTING LVT
NEW RUBBER TILE
(RT-1)
METAL FLOORING TRANSITION- SIZED
PER FLOORING MATERIAL THICKNESS
(TRAN-2)
ALIGN NEW FLOORING
TRANSITION WITH
CENTERLINE OF EXISITNG
DOOR FRAME (TRAN-2)
T R
A N
S
IT
IO
N
L E
S S
T H
A N
/4
SAFETY MESH: P-3
SAFETY MESH: P-3
BALUSTER: P-3
METAL MESH
SUPOORT: P-3
POST SHOE: P-3
DRYWALL: P-1
SAFETY MESH: P-3
POST: P-3
POST: P-3
DRYWALL: P-1
EXISTING
STRUCTURE W/
FIELD PAINT: P-1
DRYWALL: P-1
P-1
SAFETY MESH &
SUPPORTS: P-3
BALUSTER: P-3
BAULSTER TOP
RAIL: P-3
POST & POST
SHOE: P-3
CONCRETE
EXISTING TO
REMAIN
EXISTING
FLOORING TO
REMAIN
HANDRAIL:
P-3. TYPICAL.
LANDING
FASCIA: P-5
LANDING
FASCIA: P-5
BALUSTER &
BOTTOM RAIL: P-5
STRINGER:
P-5. TYPICAL.
STAIR RISER
(TYPICAL FOR PAINTED
RISERS ONLY): P-5
LANDING
FASCIA: P-5
STRINGER
(TYPICAL): P-5
POST SHOE -
CONTINUED BELOW: P-3
POST SHOE:
P-3
FACSIA: P-5
STAIR PAN: P-5
STAIR PAN: P-5
BALUSTER TOP
RAIL: P-3
POST: P-3
POST SHOE: P-3
BALUSTER
BOTTOM RAIL: P-3
STRINGER: P-5
POST: P-3
POST SHOE: P-3
POST & POST
SHOE: P-3
LANDING FASCIA
(TYPICAL): P-5
BALUSTER BOTTOM
RAIL: P-3
BALUSTER
(TYPICAL): P-3
METAL DOOR
AND FRAME
(TYPICAL) : P-7
ACOUSTICAL CEILING GRID WITH
LAY-IN TILE (TYPICAL)
GALVANIZED STEEL HANGER
WIRE SUSPENDED FROM JOISTS
T-BAR GRID OF ACOUSTIC
CEILING SYSTEM
L-ANGLE MOLDING
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C
U s e rs
\a k a n u s k y \D o c u m e n ts
\2 -U
S D
V A
-0 M
IS
C
P R
O J E
C T
S A
R C
H a k a n u s k y V
B N
S Y
.r v t
/2
/2
:3 :2
A
M
1-AI101
INTERIOR FINISH SCHEDULE, INTERIOR CEILING &
FINISH DETAILS AND NOTES
10/18/2021
Veterans Health Administration New Jersey Health Care System
561A4-15-102CORRECT FCA F RATED DEFICIENCIES
BUILDING 1
100% FINAL DOCUMENTS
GENERAL NOTES - INTERIOR FINISHES
INTERIOR FINISH LEGEND
SPEC.
SECTION CODE MATERIAL TYPE BASIS OF DESIGN STYLE SIZE COLOR FINISH COMMENTS
09.51.00
09.51.00 AT-1 ACOUSTICAL
CEILING TILE
ARMSTRONG ULTIMA HEALTH ZONE - SQUARE LAY-IN 1935 24"x24" WHITE CEILING TILE
AND WHITE GRID
DURABRITE (STANDARD) ALL NEW CEILING TILE IN SCOPE. REFER TO REFLECTED CEILING PLANS FOR SCOPE OF WORK.
09.65.13
09.65.13 RB-1 RUBBER BASE TARKETT BASEWORKS W/ TOE 4"H 40 BLACK B N/A ALL FLOOR BASE IN SCOPE OF PROJECT.
09.65.13 TRAN-1 METAL FLOORING
TRANSITION
SCHLUTER SCHIENE RADIUS EDGE TRIM 1/8" STN STEEL 1/8"Hx120"L N/A STAINLESS STEEL GC TO CONFIRM FLOORING HEIGHT TRANSITION FOR NEW AND EXISTING FLOORING. GC TO ENSURE
LEVEL FINISH BETWEEN EXISTING AND NEW FLOORING.
09.65.13 TRAN-2 METAL FLOORING
TRANSITION
SCHLUTER RENO-U REDUCER 1/8" ALUM SATIN 1/8"Hx120"L N/A SATIN ANODIZED (ALUMINUM) GC TO CONFIRM FLOORING HEIGHT TRANSITION FOR NEW AND EXISTING FLOORING. GC TO ENSURE
LEVEL FINISH BETWEEN EXISTING AND NEW FLOORING.
09.65.19
09.65.19 RT-1 RUBBER FLOOR
TILE
TARKETT SOLID COLOR/ RICE PAPER TEXTURE; PART
NUMBER: FRPA 55 1/8 24X24
24"x24"x1/8" 55 SILVER GREY WG N/A REFER TO FLOOR FINISH PLANS FOR LOCATIONS AND FLOOR TILE LAYOUT. START PATTERN AT
DOOR LOCATIONS. CENTER FLOOR TILES EQUALLY IN INSTALL LOCATIONS.
09.91.00
09.91.00 P-1 PAINT SHERWIN WILLIAMS REFER TO SPECIFICATIONS FOR PAINT TYPE
INFORMATION. GC TO SELECT PROPER TYPE BASED
ON APPLICATION.
N/A AGREEABLE GRAY
SW7029
EGGSHELL FIELD COLOR. UTILIZE FOR WALLS, DRYWALL/PLASTER CEILINGS, DRYWALL/PLASTER INTERIOR WINDOW SILLS, EXISTING PAINTED ACCESS PANELS AND EXISTING PAINTED NON-SPRINKLER PIPING.
IF ACCESS PANELS AND NON-SPRINKLER PIPING IS NOT PAINTED, FINISH TO BE EXISTING TO REMAIN.
09.91.00 P-2 PAINT SHERWIN WILLIAMS REFER TO SPECIFICATIONS FOR PAINT TYPE
INFORMATION. GC TO SELECT PROPER TYPE BASED
ON APPLICATION.
N/A URBANE BRONZE
SW7048
SEMI-GLOSS INTERIOR METAL DOOR AND DOOR FRAME COLOR. PAINT DOOR AND FRAME IN ITS ENTIRETY. DO
NOT PAINT EXISTING INTERIOR WOOD DOORS TO REMAIN, UNLESS ALREADY PAINTED.
09.91.00 P-3 PAINT SHERWIN WILLIAMS REFER TO SPECIFICATIONS FOR PAINT TYPE
INFORMATION. GC TO SELECT PROPER TYPE BASED
ON APPLICATION.
N/A DORIAN GRAY SW7017 SEMI-GLOSS ALL HANDRAILS, SAFETY MESH, AND RELATED SUPPORTS IN STAIR HALLS IN SCOPE.
09.91.00 P-4 PAINT SHERWIN WILLIAMS REFER TO SPECIFICATIONS FOR PAINT TYPE
INFORMATION. GC TO SELECT PROPER TYPE BASED
ON APPLICATION.
N/A RED; SEE COMMENTS GC TO DETERMINE BASED ON
APPLICATION, STANDARD
REQUIREMENTS AND INDUSTRY
STANDARDS. SEE SPECIFICATIONS.
USE FOR EXISTING AND NEW FIRE-RETARDANT PIPING IN MECHANICAL ROOM AND SPRINKLER
PIPING THROUGHOUT SCOPE OF WORK. RED COLOR TO BE IN ACCORDANCE W/ ANSI Z535.1-2017:
SAFETY COLORS.
09.91.00 P-5 PAINT SHERWIN WILLIAMS REFER TO SPECIFICATIONS FOR PAINT TYPE
INFORMATION. GC TO SELECT PROPER TYPE BASED
ON APPLICATION.
N/A COLOR MATCH
EXISITNG STAIR
TREADS.
SEMI-GLOSS ALL PAINTED STAIR RISERS, UNDERSIDE OF METAL STAIR PAN, PAINTED METAL STRINGERS &
LANDING FASCIA IN SCOPE. DO NOT CONTINUE PAINT ONTO POSTS.
09.91.00 P-6 PAINT SHERWIN WILLIAMS REFER TO SPECIFICATIONS FOR PAINT TYPE
INFORMATION. GC TO SELECT PROPER TYPE BASED
ON APPLICATION.
N/A RED BARN SW7591 SEMI-GLOSS USE FOR EXTERIOR CELLAR ACCESS DOOR.
09.91.00 P-7 PAINT SHERWIN WILLIAMS REFER TO SPECIFICATIONS FOR PAINT TYPE
INFORMATION. GC TO SELECT PROPER TYPE BASED
ON APPLICATION.
N/A URBANE BRONZE
SW7048
SEMI-GLOSS ALL PAINTED EXTERIOR METAL DOORS IN SCOPE. PAINT DOOR AND FRAME IN ITS ENTIRETY.
RESILIENT BASE AND ACCESSORIES
RESILIENT TILE FLOORING
PAINT
6" = 1'-0"1
DETAIL - METAL FLOORING
TRANSITION - RUBBER TILE
TO VCT
6" = 1'-0"2
DETAIL - METAL FLOORING
TRANSITION - RUBBER TILE
TO LVT
STAIR HALL EXISTING PHOTOS - PAINTING NOTES
GENERAL NOTES:
1. REFER TO FLOOR FINISH DRAWINGS FOR ALL NEW FLOORING LOCATIONS.
2. TRANSITIONS TO OCCUR AT CENTERLINE OF DOORS & OPENINGS. DRAWING ASSIGNS TRANSITIONS
THROUGH GRAPHIC REPRESENTATION.
3. INSTALL NEW WALL BASE AT EXISTING WALL BASE LOCATIONS.
4. DO NOT PAINT WOOD DOORS THAT ARE EXISITNG TO REMAIN.
5. EXISTING STAIR TREADS AND RISERS TO REMAIN AS EXISITNG, UNLESS PAINTED.
6. REFER TO REFLECTED CEILING PLANS FOR CEILING TYPE ASSIGNMENT.
ACOUSTICAL CEILING TILE
3" = 1'-0"3
DETAIL - TYPICAL NEW ACT CEILING (AT-1)