This document package includes construction drawings and specifications for a federal contract opportunity to correct fire code deficiencies in Building 1 at the VA New Jersey Healthcare System located in Lyons, New Jersey. The contractor shall demolish existing structures, prepare the site for construction, and perform all work required by the drawings and specifications to correct the deficiencies. The project value is between $1-5 million and work must be completed within 365 days of the notice to proceed. A pre-bid site walkthrough will be held on June 2, 2022. The solicitation is set aside for Service-Disabled Veteran Owned Small Businesses with a NAICS code of 236220 and size standard of $39.5 million. The Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2 is the contracting agency.
View the file
Other files for this federal contract opportunity
Show all 25
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EXISTING RAIL
EXISTING
BALLUSTERS
BEYOND
NEW HANDRAIL IN
FOREGROUND
NEW 1/4" PLATE WELDED TO EXISTING
BALLUSTERS FOR HANDRAIL BRACKET
ATTACHMENT
NEW HANDRAIL BRACKET
EXISTING PAINTED FENCE
1/4 1
1/4 1
1-AE113
2C
NEW GATE
- HARDWARE SET 1H
- PAINT
1-AE113
2B
1-AE113
2A
GROUND FLOOR
294' - 0"
NEW PAINTED GATE -
2"x1"x1/8" STEEL RECTANGULAR TUBE FRAME WITH 1"x1"x1/8" VERTICAL SQUARE
TUBE BALUSTERS
SELF CLOSING HINGE TOP & BOTTOM,
REFER TO HARDWARE SET 1H
HANDRAIL, SEE DETAILS THIS SHEET
EXISTING POST
EXISTING FENCING
1/4"x3"x2'-8" LG. PLATE STEEL FOR HINGE
ATTACHMENT, ATTACH TO EXISTING
CONCRETE COLUMN W/ (2) MASONRY
ANCHORS ABOVE & BELOW HINGES
NOTES:
A. ALL EXPOSED STEEL TO BE PAINTED
B. PROVIDE ENOUGH SPACE TO ALLOW GATE TO PASS BY HANDRAIL EXTENSION
NOTE B5 1/2"
1/4"x1 1/2"x5" LG. PLATE STEEL
STOP WELDED TO GATE
MIN.
2 1/4"
1 1/2" DIA.
M A
X
IM
U M
A F
F
M
IN
IM
U
M A
F F
LINE OF FINISHED FLOOR/ STAIR TREAD
1/4" DIAMETER BRACKET. ATTACH TO
NEW BLOCKING IN WALL OR NEW
BRACKET PLATE (4/1-AE113), AS
REQUIRED
EXISTING WALL OR CLOSEST POINT OF
EXISTING RAILING
PAINTED PIPE HANDRAIL
1/4" DIAMETER BRACKET. ATTACH
TO NEW BLOCKING IN WALL OR
NEW BRACKET PLATE (4/1-AE113),
AS REQUIRED
EXISTING WALL OR CLOSEST
POINT OF CONNECTION
PAINTED PIPE HANDRAIL
LINE OF LAST/ FIRST
STAIR NOSING
DEPTH OF TREAD (MIN.)DEPTH OF (1) TREAD
D
IA
M E
T E
R
/2
M
IN
/4
1-AE113
LINE OF FINISHED FLOOR
M A
X
IM
U M
A F
F
M
IN
IM
U M
T O
MIN.
1' - 0"
DEPTH
(1) TREAD
1-AE113
TYPICAL
PAINTED METAL PIPE
HANDRAIL
OUTLINE OF OF STAIR
TREADS & RISERS
M
A X
IM
U
M A
F F
M
IN
IM
U M
T O
EXISTING CONCRETE
COLUMN
NEW HINGE FASTENED TO
STEEL PLATE
1/4"x3"x2'-8" LG. PLATE STEEL FOR
HINGE ATTACHMENT, ATTACH TO
EXISTING CONCRETE COLUMN W/ (2)
MASONRY ANCHORS ABOVE &
BELOW HINGES
NEW GATE
NOTE: ALL EXPOSED STEEL TO BE PAINTED
SILENCER
NEW GATE EXISTING POST
1/4"x1 1/2"x5" LG. PLATE STEEL
STOP WELDED TO GATE
NOTE: ALL EXPOSED STEEL TO BE PAINTED
HSS 2 1/2x2 1/2x1/8, CAP THE TOP W/
1/4" PLATE FOR ANCHOR ROD
ATTACHMENT
HSS 3x3x3/16
EXISTING FLOOR SLAB
HILTI 3/4"⌀ x 9 3/4" HIT-Z ACHOR
ROD W/ HILTI HIT-HY 200 ADHESIVE
NOTE: HEIGHT OF POST TO MATCH ADJACENT EXISTING POSTS AT STAIR. POST HEIGHT SHOULD
ACCOMODATE HANDRAIL.
1. RETURN END OF HANDRAILS TO WALL AND CLOSE FREE END.
2. FABRICATE HANDRAIL BRACKETS FROM CAST MALLEABLE IRON.
3. PROVIDE STANDARD TERMINAL CASTINGS WHERE FASENED TO NEWEL.
4. SPACE HANDRAIL BRACKETS NO MORE THAN 48" O.C.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANTS
321 4 5 6 7 8 9 10
C
U s e rs
\a k a n u s k y \D o c u m e n ts
\2 -U
S D
V A
-0 M
IS
C
P R
O J E
C T
S A
R C
H a k a n u s k y V
B N
S Y
.r v t
/2
/2
:3 :2
A
M
1-AE113
DOOR REPLACEMENT PLANS AND RAILING DETAILS
10/18/2021 JLH ACELA
Veterans Health Administration New Jersey Health Care System
561A4-15-102CORRECT FCA F RATED DEFICIENCIES
BUILDING 1
100% FINAL DOCUMENTS
1 1/2" = 1'-0"4
TYPICAL MID-RAIL BRACKET DETAIL
3/4" = 1'-0"1
GATE DETAIL - PLAN VIEW
1" = 1'-0"2A
GATE DETAIL - ELEVATION
3" = 1'-0"6
TYPICAL HANDRAIL DETAIL
3" = 1'-0"7
TYPICAL HANDRAIL RETURN DETAIL
1/2" = 1'-0"5
TYPICAL HANDRAIL ELEVATION
3" = 1'-0"2C
GATE - HINGE END DETAIL
3" = 1'-0"2B
GATE - STOP END DETAIL
1 1/2" = 1'-0"3
BASE DETAIL AT POST
GENERAL NOTES - RAILINGS
Revisions: Date: Page 27 of 50