DNC-810CM3030_Submission_BD_Plans_Part4.pdf
PDF 6 MB Posted
- Solicitation number
- 36C78623B0033
About this file
This package of construction documents specifies requirements for renovations at the Dayton National Cemetery in Montgomery County, Ohio. The project includes replacing an existing committal shelter building, renovating the administration building, and repairing roads. Structural, architectural, civil, mechanical, electrical, and landscaping drawings and details are provided along with specifications for foundations, masonry, steelwork, and other building elements. The solicitation number is 36C78623B0033 and responses are due by July 28, 2023.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4' -0
" M
IN
3' -0
6'
-0
8'-0"
LOGO LETTERS TO BE WHITETOP BACKGROUND TO
NEW VA BLUE (MP9009)
BACKGROUND TO BE PAINTED WHITE
MATTHEWS NO. MP32071
HELVETICA STYLE 4-1/2"
HIGH LETTERING; BLACK.
CENTERED HORIZONTAL
FACE PANEL TO BE
EXTERIOR GRADE MDO
SHEET OR ALUMINUM
SKIN LAMINATED TO A
WOOD CORE WITH EDGES
PHYSICALLY SEALED;
ATTACHED TO POST WITH
WOOD SCREWS AND LAG
BOLTS
4"x6" WOOD
POST
4"X6" WOOD POSTS
PAINTED WHITE
3" 41 2"
41 2" 1'
-8
5 1/2"
2"X4" WOOD FRAMING
LETTERING TO BE
HELVETICA STYLE 1"
HIGH TO BE CENTERED
HORIZONTAL
4" 41 2"
21 2" 2"
21 2"
4"
NOTE:
1. ANY SEAM IN METAL TO BE
FLAT SEAM - SEAMS TO BE
HORIZONTAL AND OCCUR
BETWEEN LINES OF
LETTERING.
2. CONTRACTOR TO SUBMIT
SHOP DRAWINGS FOR
APPROVAL PRIOR TO
FABRICATION
3. MATERIAL TO BE SUPPLIED,
ASSEMBLED AND
INSTALLED BY
CONTRACTOR
ALL LETTERING TO BE
PAINTED BLACK WITH
EXCEPTION OF LOGO
WHICH IS AS NOTED.
ELEVATION SECTION ON CENTERLINE
U.S. Department of Veterans Affairs
21 2"
41 2"
21 2"
BLUE
4" 9"
11 2" 11 2"
3 4" 11 2"
WHITE
RED
WOOD
STRIPS
3' -0
4'-0"
3' -0
" M
IN
FINISH
GRADE
4"X4" WOOD
POST PAINTED
WHITE
2X4 BRACING, TYP.
U.S. Department of Veterans Affairs
ZERO IN
ON SAFETY
CL
NOTE:
1. ANY SEAM IN METAL TO BE
FLAT SEAM - SEAMS TO BE
HORIZONTAL AND OCCUR
BETWEEN LINES OF
LETTERING.
2. CONTRACTOR TO SUBMIT
SHOP DRAWINGS FOR
APPROVAL PRIOR TO
FABRICATION
3. MATERIAL TO BE SUPPLIED,
ASSEMBLED AND
INSTALLED BY
CONTRACTOR
PROVIDE JOINT
BRACING, TYP.
07/28/2023
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
MONTGOMERY COUNTY, OHIO
810CM3030
JULY 28, 2023 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRSIntegrity Federal Services
(304) 725-8456
Fil e P ath : G
:\P
RO
J-2
2\2
_V
AN
CA
ID
IQ
MW
_D
AY
TO
N_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
RE
NO
VA
TI
ON
\20
9C
AD
\16
8_
0C M3
2C
I51 0.D
W G
GORDON - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
TEMPORARY SITE
SIGNAGE DETAILS
CI513
171DMM JDB
SCALE: NTS
TEMPORARY CONSTRUCTION SIGN1 SCALE: NTS
TEMPORARY SAFETY SIGN2
AutoCAD SHX Text SUPERVISED BY: DEPARTMENT OF VETERANS AFFAIRS WASHINGTON D.C. NATIONAL CEMETERY ADMINISTRATION OFFICE OF DESIGN AND CONSTRUCTION
AutoCAD SHX Text
GENERAL CONTRACTOR
AutoCAD SHX Text New PIC/ADMIN Bldg, AutoCAD SHX Text GORDON ׀ THE LA GROUP SDVOSB JOINT VENTURE, THE LA GROUP SDVOSB JOINT VENTURE, INTEGRITY FEDERAL SERVICES, APOGEE CONSULTING GROUP, FORESITE GROUP
AutoCAD SHX Text
DESIGNED BY:
AutoCAD SHX Text xxxxxx
AutoCAD SHX Text Replace Committal Shelter B, Shelter B, Shelter B, AutoCAD SHX Text Dayton National Cemetery
AutoCAD SHX Text and Road Repairs
AutoCAD SHX Text
THIS PROJECT HAS WORKED
AutoCAD SHX Text
AutoCAD SHX Text
DAYS
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
WITHOUT A LOST TIME ACCIDENT
AutoCAD SHX Text
THE LIFE YOU SAVE MAY BE YOUR OWN
AutoCAD SHX Text
GENERAL CONTRACTOR
CUSTOM
CUSTOM
VISITOR INFORMATION
FLORAL REGULATIONS
INFORMATION / REGULATION SIGN SCHEDULE (INFO)
SIGN KEY:
INFO1
INFO2
SIGN DESCRIPTION SIGN COPY NORTHING
641401.09
641238.91
EASTING
1474110.17
1474325.18
HORIZONTAL YOU ARE HERE (MAP)
SIGN KEY:
MAP1
SIGN DESCRIPTION SIGN COPY NORTHING
641233.70
EASTING
1474325.67CUSTOM MAP OF CEMETERY
LOW PROFILE TRAFFIC REGULATORY SIGN SCHEDULE (REG)
SIGN KEY:
REG1
REG2A
REG2B
REG3
REG4A
REG4B
REG4C
REG4D
REG5
REG6A
REG6B
REG7A
REG7B
SIGN DESCRIPTION SIGN COPY NORTHING
641473.40
641445.24
641030.78
641183.29
641071.86
641105.90
641196.63
641223.57
641105.90
641196.63
641223.57
641206.35
641246.76
EASTING
1473927.22
1473951.40
1474079.59
1474322.47
1474001.97
1473998.37
1474003.56
1473996.23
1473998.37
1474003.56
1473996.23
1474075.11
1474035.72
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
CUSTOM
FUNERAL PROCESSION KEEP RIGHT
SPEED LIMIT 15
SPEED LIMIT 15
EMPLOYEE PARKING ONLY
AUTHORIZED VEHICLES ONLY
AUTHORIZED VEHICLES ONLY
AUTHORIZED VEHICLES ONLY
AUTHORIZED VEHICLES ONLY
STOP
YIELD
YIELD
ALL FUNERALS WAIT HERE
ALL FUNERALS WAIT HERE
TALL TRAFFIC REGULATORY (TTR)
SIGN KEY:
TTR1A
TTR1B
TTR1C
TTR1D
SIGN DESCRIPTION SIGN COPY NORTHING
641258.68
641243.39
641086.13
641068.15
EASTING
1474320.68
1474323.63
1474068.89
1474069.65
CUSTOM
CUSTOM
CUSTOM
CUSTOM
RESERVED PARKING / VAN ACCESSIBLE / $250 FINE
MINIMUM
RESERVED PARKING / VAN ACCESSIBLE / $250 FINE
MINIMUM
RESERVED PARKING / VAN ACCESSIBLE / $250 FINE
MINIMUM
RESERVED PARKING / VAN ACCESSIBLE / $250 FINE
MINIMUM
POST AND PANEL (PPC & PPD)
SIGN KEY:
PPC1
PPD1
SIGN DESCRIPTION SIGN COPY NORTHING
641117.41
641356.75
EASTING
1474066.56
1474284.51
CUSTOM
CUSTOM ADMINISTRATION / PUBLIC INFORMATION CENTER /
RESTROOMS
MAINTENANCE BUILDING ANNEX
HONOR GUARD
FLAG SLEEVE LAYOUT POINTS
SIGN KEY:
FS1
FS2
FS3
FS4
FS5
FS6
FS7
FS8
FS9
FS10
FS11
NORTHING
641469.26
641434.13
641412.70
641406.26
641402.92
641399.35
641391.29
641373.16
641344.53
641311.86
641275.69
EASTING
1473931.73
1473966.65
1474011.99
1474064.05
1474116.13
1474167.98
1474222.46
1474263.73
1474300.05
1474324.56
1474341.08
TEMPORARY (TEMP)
SIGN KEY:
TEMP1
TEMP2
SIGN DESCRIPTION SIGN COPY NORTHING
641491.89
641496.64
EASTING
1473956.68
1473964.33
SP-24.01 CONSTRUCTION SIGN: TEXT ONLY
SP-24.04 CONSTRUCTION SIGN: SAFETY
07/28/2023
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
MONTGOMERY COUNTY, OHIO
810CM3030
JULY 28, 2023 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRSIntegrity Federal Services
(304) 725-8456
Fil e P ath : G
:\P
RO
J-2
2\2
_V
AN
CA
ID
IQ
MW
_D
AY
TO
N_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
RE
NO
VA
TI
ON
\20
9C
AD
\16
5_
0C M3
2C
I10 0.D
W G
GORDON - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
SITE SIGNAGE AND SITE
FURNISHINGS SCHEDULE
CI600
172DMM JDB
GENERAL NOTES
1. FOR SITE FURNISHING DETAILS SEE CI501.
2. EXTERIOR SIGNAGE IS TO MATCH THE EXISTING
VAMC CAMPUS STYLE SIGNAGE AT THE CEMETERY.
SEE SIGN DETAILS FOR ADDITIONAL INFORMATION.
3. LOCATIONS AND QUANTITIES SHOWN FOR NEW
FLAG SLEEVES ARE FOR BIDDING PURPOSES.
LOCATIONS OF FLAG SLEEVES ARE TO ALIGN WITH
EXISTING LOCATIONS IMPACTED BY
CONSTRUCTION.
DS
DS
DS
DS
DS
DS
9+
+0
+0
12+
+0
14+00
+6
MCMAHON AVE
WISCONSIN AVE
MONUMENT AVE
MONUMENT AVE
BROWN AVE
WISCONSIN AVE
HAW
AII PL
WISCONSIN AVE
EXISTING BURIAL
SECTION F
EXISTING BURIAL
SECTION D
EXISTING BURIAL
SECTION C
EXISTING BURIAL
SECTION B
EXISTING BURIAL
SECTION G
EXISTING BURIAL
SECTION 20
EXISTING BURIAL
SECTION 25
EXISTING BURIAL
SECTION 30
EXISTING BURIAL
SECTION 35
EXISTING BURIAL
SECTION CIV
EXISTING
MONUMENT
WEST 3RD STREET
SEE SHEET LS101 FOR
PIC/ADMINISTRATION
BUILDING LANDSCAPE
ENLARGEMENT PLAN
AR
OV
OV
AS
SEE SHEET LS102 FOR STORMWATER
MANAGEMENT AREA LANDSCAPE
ENLARGEMENT PLAN
NEW LAWN SOD,
TYP.
OV
NEW MEXICO PL
MP
IN
DI
AN
A
AV
E
BROWN AVE
NEW LAWN SOD, TYP.
NEW MULCH BED
TO LIMITS OF
DISTURBANCE, TYP.
07/28/2023
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
MONTGOMERY COUNTY, OHIO
810CM3030
JULY 28, 2023 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRSIntegrity Federal Services
(304) 725-8456
Fil e P ath
G:
\P
RO
J-2
2\2
_V
AN
CA
ID
IQ
MW
_D
AY
TO
N_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
RE
NO
VA
TI
ON
\20
9C
AD
\17 3_
0C
M3
2L S1
.D
W G
GORDON - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
OVERALL LANDSCAPE PLAN
LS100
173DMM JDB
NORTH
10 20 3030 0
Scale: 1" = 30'
LEGEND
GENERAL NOTES
PROPERTY LINE
1. CONTRACTOR TO COORDINATE WITH CEMETERY
STAFF TO MINIMIZE DISTURBANCE TO CEMETERY
OPERATIONS.
2. IF ADDITIONAL AREAS ARE DISTURBED FROM
CONSTRUCTION OPERATIONS, CONTRACTOR SHALL
RESTORE DISTURBED AREAS TO EXISTING
CONDITIONS.
3. SEE SHEET LS500 FOR PLANTING DETAILS AND
SCHEDULE.
1" = 30'-0"
COMMITTAL SERVICE SHELTER B INSET1 10 20 300
LAWN SOD
DECIDUOUS TREE
SMALL ORNAMENTAL TREE
EVERGREEN TREE
AutoCAD SHX Text T
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
VLT
AutoCAD SHX Text
VLT
AutoCAD SHX Text
VLT
AutoCAD SHX Text
VLT
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text S
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
EH
AutoCAD SHX Text S
AutoCAD SHX Text APPROX. POTENTIAL LOCATION OF BURIED STORM STRUCTURE & PIPE LINE CONNECTION (PER KZF INCORPORATED, JOB NO. 810CM3012, DATED: 6/30/98)
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
EH
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
ST
DS
AS
CC
WISCONSIN AVE
MP
PO
07/28/2023
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
MONTGOMERY COUNTY, OHIO
810CM3030
JULY 28, 2023 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRSIntegrity Federal Services
(304) 725-8456
Fil e P ath
G:
\P
RO
J-2
2\2
_V
AN
CA
ID
IQ
MW
_D
AY
TO
N_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
RE
NO
VA
TI
ON
\20
9C
AD
\17 3_
0C
M3
2L S1
.D
W G
GORDON - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
PIC / ADMINISTRATION BUILDING
LANDSCAPE PLAN ENLARGEMENT
LS101
174DMM JDB
NORTH
2 4 6 88 0
LEGEND
PROPERTY LINE
EXISTING BURIAL SECTIONS
LAWN SOD
DECIDUOUS TREE
SMALL ORNAMENTAL TREE
EVERGREEN TREE
NOTES
1. SEE SHEET LS100 FOR NOTES.
Scale: 1" = 8'
M
AT
CH
LI
NE
S
EE
L
S1
M
AT
CH
LI
NE
S
EE
L
S1
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
EH
+0
12+
PG
PB
PG
MCMAHON AVE
PG
MP
07/28/2023
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
MONTGOMERY COUNTY, OHIO
810CM3030
JULY 28, 2023 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRSIntegrity Federal Services
(304) 725-8456
Fil e P ath
G:
\P
RO
J-2
2\2
_V
AN
CA
ID
IQ
MW
_D
AY
TO
N_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
RE
NO
VA
TI
ON
\20
9C
AD
\17 3_
0C
M3
2L S1
.D
W G
GORDON - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
STORMWATER MANAGEMENT AREA
LANDSCAPE PLAN ENLARGEMENT
LS102
175DMM JDB
NORTH
LEGEND
PROPERTY LINE
LAWN SOD
DECIDUOUS TREE
SMALL ORNAMENTAL TREE
EVERGREEN TREE
NOTES
1. SEE SHEET LS100 FOR NOTES.
2 4 6 88 0
Scale: 1" = 8'
M
AT
CH
LI
NE
S
EE
L
S1
M
AT
CH
LI
NE
S
EE
L
S1
AutoCAD SHX Text I
AutoCAD SHX Text I
ST
07/28/2023
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
MONTGOMERY COUNTY, OHIO
810CM3030
JULY 28, 2023 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRSIntegrity Federal Services
(304) 725-8456
Fil e P ath
G:
\P
RO
J-2
2\2
_V
AN
CA
ID
IQ
MW
_D
AY
TO
N_
NA
TI
ON
AL
_C
EM
ET
ER
Y_
RE
NO
VA
TI
ON
\20
9C
AD
\17 3_
0C
M3
2L S1
.D
W G
GORDON - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
LANDSCAPE DETAILS
AND SCHEDULE
LS500
176DMM JDB
PLANT LIST
SYM. QTY. BOTANICAL NAME COMMON NAME SIZE REMARKS/SPACING
DECIDUOUS TREES
AS 2 Acer saccharum Sugar Maple 2-2 1/2" Cal. B&B
AR 2 Acer rubrum 'October Glory' October Glory Red Maple 2-2 1/2" Cal. B&B
OV 4 Ostrya virginiana American Hop-hornbeam 2-2 1/2" Cal. B&B
ORNAMENTAL TREES
CC 2 Cercis canadensis 'Forest Pansy' Forest Pansy Redbud 8'-10' ht. B&B, SINGLE STEM
EVERGREEN TREES
PG 5 Picea glauca White Spruce 6'-8' hr. B&B
PB 3 Picea pungens Colorado Blue Spruce 8'-10' ht. B&B
SHRUBS
MP 12 Myrica pensylvanica Bayberry 24"-30" ht. FEMALE AND 1 MALE PO 2 Physocarpus opulifolius 'Diabolo' Diabolo Ninebark #5 Cont.
3" DEPTH MULCH
4" HT. PLANTING MIX SAUCER
CUT AND REMOVE BURLAP FROM
TOP 1/3 OF ROOT BALL6"
MIN.
LIGHTLY TAMPED AMENDED
BACKFILL
SCARIFY SUBSOIL TO MIN. 4" DEPTH
NOTE: SPACE SHRUBS AS
INDICATED ON PLANS
6" 4"
N.T.S.
SHRUB PLANTING5
STAKE
TREE TRUNK
STAKESTAKE
STAKE
TREE TRUNK
STAKESTAKE
PLAN
VIEW
PLAN
VIEW
STRAPS. ENCASE STRAPS AROUND TRUNK
DRIVEN IN ON AN SLIGHT ANGLE.
STAKES TO BE OUTSIDE OF ROOT BALL.
3 PER TREE. STAKES TO BE SAME HEIGHT,
IN REINFORCED RUBBER HOSE ABOVE
FIRST BRANCH. SECURE GUYING STRAPS
3" Ø x 8'-0" CEDAR STAKES, 4" HT. PLANTING MIX SAUCER
WITH GALV. OR CADMIUM-PLATED TURNBUCKLES.
PERIMETER OF MOUND TO DEPTH SHOWN.
COMPACTED 92%; TRENCH AROUND
UNDISTURBED NATIVE SOIL DRAINAGE MOUND
AMENDED PLANTING MIX, COMPACTED
3" DEPTH HARDWOOD MULCH;
PULL MULCH AWAY FROM TRUNK
(SEE SPEC.)
2'-0"
TYP.
1' -0
F.G.
TO STAKE. NOTCH STAKE TO RECEIVE
ATTACH FABRIC MATERIAL GUYING STRAPS
NOTES:
2'-0"
TYP.
1' -0
F.G.
COMPACTED 92%; TRENCH AROUND PERIMETER
OF MOUND TO DEPTH SHOWN.
BOTTOM OF TREE TRUNK AFTER BACKFILLING
TOP 1/3 OF BALL ROOT. IF PLASTIC WRAP OR
BUT BEFORE MULCHING. REMOVE BURLAP FROM
TREATED BURLAP IS USED, COMPLETELY REMOVE
AMENDED PLANTING MIX, COMPACTED
UNDISTURBED NATIVE SOIL DRAINAGE MOUND
3 PER TREE. STAKES TO BE SAME HEIGHT,
STAKES TO BE OUTSIDE OF ROOT BALL.
3" DEPTH HARDWOOD MULCH;
4" HT. PLANTING MIX SAUCER
PULL MULCH AWAY FROM TRUNK
3" Ø x 8'-0" CEDAR STAKES, DRIVEN IN ON AN SLIGHT ANGLE.
(SEE SPEC.)
TREES 8'-0" HT. & LARGER SHALL
TREE SHALL BE PLUMB & STRAIGHT;
NEVER CUT A LEADER.
BE GUYED AS SHOWN BELOW.
NOTES:
STRAPS. ENCASE STRAPS AROUND TRUNK
IN REINFORCED RUBBER HOSE ABOVE
FIRST BRANCH. SECURE GUYING STRAPS
WITH GALV. OR CADMIUM-PLATED TURNBUCKLES.
TO STAKE. NOTCH STAKE TO RECEIVE
ATTACH FABRIC MATERIAL GUYING STRAPS
CONTRACTOR TO REMOVE GUYING TWO (2)
GROWING SEASONS AFTER INSTALLATION.
1" HIGHER THAN THE SURROUNDING GRADE.
SET PLANT SO THAT THE ROOT CROWN IS
MUST BE REMOVED. CUT ROPE SURROUNDING
ANY WIRE CAGING OR SIMILAR MATERIAL
THESE MATERIALS.
BOTTOM OF TREE TRUNK AFTER BACKFILLING
TOP 1/3 OF BALL ROOT. IF PLASTIC WRAP OR
BUT BEFORE MULCHING. REMOVE BURLAP FROM
TREATED BURLAP IS USED, COMPLETELY REMOVE
MUST BE REMOVED. CUT ROPE SURROUNDING
ANY WIRE CAGING OR SIMILAR MATERIAL
THESE MATERIALS.
SECTION
VIEW
N.T.S.
DECIDUOUS TREE PLANTING1 N.T.S.
CONIFEROUS TREE PLANTING2
SECTION
VIEW
TREE SHALL BE PLUMB & STRAIGHT; TREES
2-1/2" CALIPER & LARGER SHALL BE
STAKED & GUYED AS SHOWN BELOW.
SET PLANT SO THAT THE ROOT CROWN IS 1"
HIGHER THAN THE SURROUNDING GRADE.
THIN BRANCHES & FOLIAGE AS DIRECTED (SEE
SPECS) WHILE RETAINING NORMAL SHAPE OF
TREE. NEVER CUT A LEADER.
N.T.S.
NOT USED4
N.T.S.
NOT USED3
NOTES:
1. SEE LS100 FOR ADDITIONAL NOTES.
2. THE CONTRACTOR SHALL SUPPLY ALL NEW PLANT MATERIAL IN QUANTITIES SUFFICIENT TO
COMPLETE ALL PLANTING SHOWN ON THE DRAWINGS. WHERE DISCREPANCIES EXIST BETWEEN THE
PLANS AND THE LANDSCAPE SCHEDULE, THE PLANS SHALL TAKE PRECEDENCE.
3. ALL DISTURBED AREAS TO BE SODDED LAWN AS APPROPRIATE. SOD SHALL MATCH EXISTING.
4. CONTRACTOR SHALL VERIFY POTENTIAL UTILITY CONFLICTS INCLUDING BUT NOT LIMITED TO
CONFLICTS BETWEEN LANDSCAPE AND UTILITIES. CONTRACTOR SHALL STAKING LANDSCAPE
LOCATIONS PRIOR TO INSTALLATION. ALL UTILITY LINES DAMAGED BY THE INSTALLATION OF PLANT MATERIAL SHALL BE REPAIRED BY THE CONTRACTOR AT NO EXPENSE TO THE GOVERNMENT. ALL UTILITIES, INCLUDING BUT NOT LIMITED TO IRRIGATION LINES, REQUIRING REROUTING SHALL BE
REPAIRED BY THE CONTRACTOR AT NO EXPENSE TO THE GOVERNMENT. IMMEDIATELY NOTIFY
GOVERNMENT AND DESIGN TEAM OF CONFLICTS. CONTRACTOR SHALL REVIEW CONTRACT
DOCUMENTS AND COORDINATE SUBCONTRACTORS WORK TO PREVENT UTILITIES IN CONFLICT WITH
LANDSCAPE.
5. SEE LANDSCAPE PLANS FOR EXISTING TREES TO REMAIN.
6. TREES SHALL BEAR SAME RELATIONSHIP TO FINISH GRADE AS IN THE NURSERY.
7. TREES SHALL BE PLUMB AND STRAIGHT.
8. CONTRACTOR IS RESPONSIBLE FOR ESTABLISHING PLANT MATERIAL. UNHEALTHY OR NON-VIGOROUS
PLANT MATERIAL SHALL NOT BE ACCEPTED. UNHEALTHY OR NON-VIGOROUS PLANT MATERIAL SHALL
BE REPLACED AND ESTABLISHED AT NO ADDITIONAL EXPENSE TO THE GOVERNMENT.
9. SEE SPECIFICATIONS FOR ADDITIONAL INFORMATION.
Dwg of
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T O
N
C E
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 003
S-001
GENERAL NOTES
JCJW 177 186JULY 28, 2023
BID DOCUMENTS
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
AE DESIGN SERVICES
GENERAL
1. NO PROVISION OF ANY REFERENCED STANDARD SPECIFICATION, MANUAL OR CODE
(WHETHER OR NOT SPECIFICALLY INCORPORATED BY REFERENCE IN THE CONTRACT
DOCUMENTS) SHALL BE EFFECTIVE TO CHANGE THE DUTIES AND RESPONSIBILITIES OF
OWNER, CONTRACTOR, DESIGN PROFESSIONAL, SUPPLIER, OR ANY OF THEIR
CONSULTANTS, AGENTS, OR EMPLOYEES FROM THOSE SET FORTH IN THE CONTRACT
DOCUMENTS. NOR SHALL IT BE EFFECTIVE TO ASSIGN TO THE DESIGN PROFESSIONAL
OF RECORD OR ANY OF THE DESIGN PROFESSIONAL OF RECORD'S CONSULTANTS,
AGENTS, OR EMPLOYEES ANY DUTY OR AUTHORITY TO SUPERVISE OR DIRECT THE
FURNISHING OR PERFORMANCE OF THE WORK OR ANY DUTY OR AUTHORITY TO
UNDERTAKE RESPONSIBILITIES CONTRARY TO THE PROVISIONS OF THE CONTRACT
DOCUMENTS.
2. CONTRACT DOCUMENTS INCLUDE, BUT ARE NOT LIMITED TO, THE STRUCTURAL
DOCUMENTS (DRAWINGS AND SPECIFICATIONS), BUT DO NOT INCLUDE SHOP
DRAWINGS, VENDOR DRAWINGS, OR MATERIAL PREPARED AND SUBMITTED BY THE
CONTRACTOR.
3. REFERENCE TO STANDARD SPECIFICATIONS OF ANY TECHNICAL SOCIETY,
ORGANIZATION, OR ASSOCIATION OR TO CODES OF LOCAL OR STATE AUTHORITIES,
SHALL MEAN THE LATEST STANDARD, CODE, SPECIFICATION OR TENTATIVE
SPECIFICATION ADOPTED AT THE DATE OF TAKING BIDS, UNLESS SPECIFICALLY STATED
OTHERWISE.
4. CONTRACT DOCUMENTS SHALL GOVERN IN THE EVENT OF A CONFLICT WITH THE
CODE OF PRACTICE OR SPECIFICATIONS OF ACI, PCI, AISC, SJI OR OTHER STANDARDS.
WHERE A CONFLICT OCCURS WITHIN THE CONTRACT DOCUMENTS, THE STRICTEST
REQUIREMENT SHALL GOVERN.
5. MATERIAL, WORKMANSHIP, AND DESIGN SHALL CONFORM TO THE REFERENCED
BUILDING CODE.
6. CONTRACTOR SHALL COORDINATE THE STRUCTURAL DOCUMENTS WITH THE
ARCHITECTURAL, MECHANICAL, ELECTRICAL, PLUMBING AND CIVIL DOCUMENTS. DESIGN
PROFESSIONAL SHALL BE NOTIFIED OF ANY DISCREPANCY OR OMISSION. FOR
DIMENSIONS NOT SHOWN ON THE STRUCTURAL DRAWINGS SEE THE ARCHITECTURAL
DRAWINGS.
7. STRUCTURAL DOCUMENTS ARE BEING RELEASED PRIOR TO DOCUMENTS BY OTHER
DISCIPLINES (ARCHITECTURAL, MECHANICAL, ETC.). CONTRACTOR SHALL COORDINATE
STRUCTURAL DOCUMENTS WITH OTHER PORTIONS OF THE CONTRACT DOCUMENTS AS
THEY ARE RELEASED. DESIGN PROFESSIONAL SHALL BE NOTIFIED OF ANY DISCREPANCY
OR OMISSION.
8. CONTRACTOR SHALL VERIFY EXISTING DIMENSIONS, ELEVATIONS, AND SITE
CONDITIONS BEFORE STARTING WORK. DESIGN PROFESSIONAL SHALL BE NOTIFIED OF
ANY DISCREPANCY.
9. CONTRACTOR SHALL VERIFY THE STRUCTURALLY SUPPORTED MECHANICAL
EQUIPMENT WEIGHTS, OPENING SIZES AND LOCATIONS IDENTIFIED ON THE
STRUCTURAL DRAWINGS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS.
10. CONTRACTOR SHALL VERIFY THAT MISCELLANEOUS FRAMING SHOWN ON THE
STRUCTURAL DRAWINGS FOR MECHANICAL EQUIPMENT, OWNER-FURNISHED ITEMS,
PARTITIONS, ETC. IS CONSISTENT WITH THE REQUIREMENTS OF SUCH ITEMS.
11. CONTRACTOR HAS SOLE RESPONSIBILITY FOR MEANS, METHODS, TECHNIQUES,
SEQUENCES, AND PROCEDURES OF CONSTRUCTION.
12. THE STRUCTURE IS STABLE ONLY IN ITS COMPLETED FORM. TEMPORARY SUPPORTS
REQUIRED FOR STABILITY DURING ALL INTERMEDIATE STAGES OF CONSTRUCTION
SHALL BE DESIGNED, FURNISHED, AND INSTALLED BY THE CONTRACTOR.
13. CONTRACTOR HAS SOLE RESPONSIBILITY TO COMPLY WITH ALL OSHA
REGULATIONS.
14. ELECTRONIC DRAWING FILES WILL NOT BE PROVIDED TO THE CONTRACTOR.
REPRODUCTION OF STRUCTURAL DRAWINGS FOR SHOP DRAWINGS IS NOT PERMITTED.
15. REVIEW OF SUBMITTALS OR SHOP DRAWINGS BY THE DESIGN PROFESSIONAL DOES
NOT RELIEVE THE CONTRACTOR OF THE SOLE RESPONSIBILITY TO REVIEW AND CHECK
ALL SUBMITTALS AND SHOP DRAWINGS BEFORE SUBMITTING TO THE DESIGN
PROFESSIONAL. CONTRACTOR REMAINS SOLELY RESPONSIBLE FOR ERRORS AND
OMISSIONS ASSOCIATED WITH THE PREPARATION OF SHOP DRAWINGS AS THEY
PERTAIN TO MEMBER SIZES, DETAILS, AND DIMENSIONS SPECIFIED IN THE CONTRACT
DOCUMENTS.
16. DETAILS LABELED "TYPICAL" ON THE STRUCTURAL DRAWINGS APPLY TO ALL
SITUATIONS OCCURRING ON THE PROJECT THAT ARE THE SAME OR SIMILAR TO THE
TYPICAL DETAILS UNLESS THOSE LOCATIONS ARE SPECIFICALLY DETAILED OTHERWISE.
17. STRUCTURAL DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR THE DESIGN OF
STEEL STAIRS, HANDRAILS, CURTAIN WALL/WINDOW WALL SYSTEMS, COLD-FORMED
METAL FRAMING, OR OTHER SYSTEMS NOT SHOWN IN THE STRUCTURAL DOCUMENTS.
SUCH SYSTEMS SHALL BE DESIGNED, FURNISHED, AND INSTALLED AS REQUIRED BY
OTHER PORTIONS OF THE CONTRACT DOCUMENTS.
CODE/DESIGN CRITERIA
1. STRUCTURE IS DESIGNED IN ACCORDANCE WITH THE FOLLOWING:
§ 2017 OHIO BUILDING CODE.
2. GRAVITY LOADS
2.1 UNIFORM FLOOR LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
§ GENERAL AREAS 100 PSF
2.2 UNIFORM ROOF LIVE LOADS (REDUCED AS ALLOWED BY THE BUILDING CODE):
§ ROOF 20 PSF
§ GROUND SNOW LOAD 20 PSF
§ SNOW EXPOSURE COEFFICIENT = 0.9
§ SNOW LOAD IMPORTANCE FACTOR = 1.0
§ THERMAL FACTOR = 1.0
PONDING AND DRIFT EFFECTS HAVE BEEN INCLUDED IN THE DESIGN.
2.3 DEAD LOADS (IN ADDITION TO STRUCTURE SELF-WEIGHT):
ROOF:
§ ROOFING 5 PSF
§ INSULATION 5 PSF
§ MISCELLANEOUS 5 PSF
§ CEILING/MEP 5 PSF
3. WIND LOADS:
§ RISK CATEGORY: II
§ BASIC WIND SPEED, Vult = 115 MPH § ALLOWABLE WIND SPEED, Vasd = 89 mph
§ EXPOSURE C
§ INTERNAL PRESSURE COEFFICIENT = +/-0.18
SEE COMPONENT AND CLADDING DESIGN WIND PRESSURE DIAGRAM
4. EARTHQUAKE LOADS:
§ SEISMIC IMPORTANCE FACTOR: I = 1.0
§ RISK CATEGORY: II
§ SHORT PERIOD MAPPED SPECTRAL RESPONSE COEFFICIENT, SS = 0.153
§ 1 SECOND PERIOD MAPPED SPECTRAL RESPONSE COEFFICIENT, S1 = 0.072
§ SITE CLASS D
§ SHORT PERIOD DESIGN SPECTRAL RESPONSE COEFFICIENT, SDS = 0.164
§ 1 SECOND PERIOD DESIGN SPECTRAL RESPONSE COEFFICIENT, SD1 = 0.116
§ SEISMIC DESIGN CATEGORY: B
§ ANALYSIS PROCEDURE: EQUIVALENT LATERAL FORCE PROCEDURE
§ BASIC SEISMIC-FORCE RESISTING SYSTEM: STEEL SYSTEM NOT SPECIFICALLY
DETAILED FOR SEISMIC RESISTANCE.
§ DESIGN BASE SHEAR:
ADMINISTRATION BUILDING – 5 KIPS
HONOR GUARD BUILDING – 3 KIPS
§ SEISMIC RESPONSE COEFFICIENT, CS = 0.055
§ RESPONSE MODIFICATION FACTOR, R = 3
5. UNLESS NOTED OTHERWISE CALCULATED INDIVIDUAL MEMBER DEFLECTIONS (IN
INCHES) DO NOT EXCEED THE FOLLOWING:
DEAD LOAD LIVE LOAD DEAD + LIVE LOAD
ROOF MEMBERS: L/360 L/360 L/240
§ WHERE, L = SPAN LENGTH (IN INCHES) BETWEEN SUPPORTS. (FOR CANTILEVERS, L IS
TWICE THE LENGTH OF THE CANTILEVER.) NOTE THAT THE TOTAL MAXIMUM
CALCULATED FLOOR SYSTEM DEFECTION WILL BE THE SUM OF THE DEFLECTIONS OF
THE SUPPORTED ELEMENTS IN A BAY.
FOUNDATION
1. FOUNDATION DESIGN IS BASED ON THE RECOMMENDATIONS IN THE GEOTECHNICAL
REPORT PREPARED BY ECS MIDWEST LLC, ECS PROJECT NUMBER 66:1189-A DATED
4/14/2023. DESIGN PROFESSIONAL IS NOT RESPONSIBLE FOR SUBSURFACE CONDITIONS
ENCOUNTERED IN THE FIELD DIFFERENT TO THOSE ASSUMED FOR DESIGN.
2. STRUCTURAL TESTING/INSPECTION AGENCY SHALL CERTIFY THE BEARING MEDIUM.
3. INDIVIDUAL SPREAD FOOTINGS AND CONTINUOUS FOOTINGS SHALL BEAR ON SOIL
CAPABLE OF SUPPORTING 3000 PSF.
3.1 NO FOOTINGS SHALL BEAR ON ROCK. UNDERCUT ROCK A MINIMUM OF 2 FEET
BELOW BOTTOM OF FOOTING AND REPLACE WITH STRUCTURAL FILL.
4. PROOFROLL BUILDING AREAS WITH TWO COMPLETE COVERAGES OF A LOADED DUMP
TRUCK OR SCRAPER.REPLACE SOFT AREAS WITH LEAN CONCRETE FILL AS REQUIRED
BY THE GEOTECHNICAL REPORT.
5. STRUCTURAL FILL SHALL CONTAIN NO ORGANIC MATERIAL AND BE APPROVED BY A
GEOTECHNICAL ENGINEER PRIOR TO PLACEMENT. STRUCTURAL FILL UNDER SLABS AND
WITHIN 10'-0" OF THE BUILDING FOOTPRINT SHALL BE PLACED IN LIFTS OF THICKNESS
DETERMINED BY THE INDEPENDENT TESTING AGENCY AND COMPACTED TO AT LEAST
95% OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM
D698. THE TOP 12" SUB-BASE UNDER SLABS ON GRADE SHALL BE COMPACTED TO AT
LEAST 98% OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY. ALL BACKFILL,
COMPACTION AND PROOF ROLLING OPERATIONS SHALL BE OBSERVED BY AN
INDEPENDENT TESTING LABORATORY.
6. SLABS-ON-GRADE SHALL BE PLACED ON A 4" GRANULAR BASE, COMPACTED TO 98%
OF ITS STANDARD PROCTOR MAXIMUM DRY DENSITY IN ACCORDANCE WITH ASTM D698,
AND COVERED WITH A 10 MIL CONTINUOUSLY SEALED VAPOR BARRIER. THE BASE FOR
SLABS-ON-GRADE SHALL BE INSPECTED BY A GEOTECHNICAL ENGINEER PRIOR TO EACH
PLACEMENT OF CONCRETE.
7. FOOTINGS SHALL BE CENTERED ABOUT COLUMN LINES UNLESS NOTED OTHERWISE.
8. ALL FOOTINGS AND TURN DOWN SLAB EDGES SHALL PENETRATE TO A MINIMUM
DEPTH OF 3'-0" BELOW FINISHED GRADE.
REINFORCEMENT
1. REINFORCING STEEL SHALL CONFORM TO ASTM A615, GRADE 60, UNLESS NOTED
OTHERWISE.
2. WELDED WIRE FABRIC SHALL CONFORM TO ASTM A185 AND HAVE MINIMUM SIDE AND
END LAPS OF 8".
3. SUBMIT SHOP DRAWINGS WHICH ADEQUATELY DEPICT THE REINFORCING BAR SIZES
AND PLACEMENT. WRITTEN DESCRIPTION OF REINFORCEMENT WITHOUT ADEQUATE
SECTIONS, ELEVATIONS, AND DETAILS IS NOT ACCEPTABLE.
5. SPLICES SHALL BE CLASS B IN ACCORDANCE WITH ACI 318, UNLESS NOTED
OTHERWISE. REINFORCEMENT SHALL BE SPLICED ONLY AT LOCATIONS SHOWN OR
NOTED IN THE STRUCTURAL DOCUMENTS, EXCEPT REINFORCEMENT MARKED
"CONTINUOUS" CAN BE SPLICED AT LOCATIONS DETERMINED BY CONTRACTOR. SPLICES
AT OTHER LOCATIONS SHALL BE APPROVED IN WRITING BY THE DESIGN PROFESSIONAL.
5. REINFORCING STEEL DESIGNATED CONTINUOUS SHALL BE LAPPED AS FOLLOWS:
§ CONCRETE REINFORCEMENT: CLASS B TENSION LAP
6. PROVIDE DOWELS FROM FOUNDATIONS THE SAME SIZE AND NUMBER AS THE
VERTICAL WALL OR COLUMN REINFORCING, UNLESS NOTED OTHERWISE.
7. PLACE REINFORCEMENT AS FOLLOWS, UNLESS NOTED OTHERWISE:
7.1 CONCRETE REINFORCEMENT COVER
EXPOSED TO EARTH OR WEATHER:
§ UNFORMED CAST AGAINST EARTH 3” CLEAR
§ FORMED #6 AND LARGER 2” CLEAR
§ FORMED #5 AND SMALLER 1-1/2” CLEAR
8. ADHESIVE FOR REINFORCING DOWELS IN EXISTING CONCRETE SHALL CONFORM TO
ASTM C881-02, TYPE IV, GRADE 3, CLASS A, B, & C EXCEPT GEL TIMES AND EPOXY
CONTENT. ADHESIVE SHALL CONSIST OF A TWO COMPONENT ADHESIVE SYSTEM
CONTAINED IN SIDE BY SIDE PACKAGING CONNECTEED TO A MIXING NOZZLE WHICH
THOROUGHLY MIXES THE COMPONENTS AS IT IS INJECTED INTO THE HOLE. ADHESIVE
SHALL HAVE PASSED ICC EVALUATION SERVICES, INC ACCEPTANCE CRITERIA 308 FOR
LONG TERM CREEP AND BE SPECIFICALLY APPROVED FOR USE IN CRACKED CONCRETE.
INSTALL IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. MINIMUM
EMBEDMENT LENGTH SHALL BE 12 BAR DIAMETERS, UNLESS NOTED OTHERWISE.
8. ALL DOWELS AND TERMINATING BARS SHALL HAVE A STANDARD 90 DEGREE HOOK.
9. ALL HORIZONTAL REINFORCING SHALL BE CONTINUOUS THROUGH CONTROL AND/OR
CONSTRUCTION JOINTS AND AROUND CORNERS.
CAST-IN-PLACE CONCRETE
1. CONCRETE WORK SHALL CONFORM TO ACI 318 AND CRSI STANDARDS.
2. CONCRETE SHALL HAVE THE FOLLOWING MINIMUM SPECIFIED 28-DAY COMPRESSIVE
STRENGTH:
2.1 NORMAL WEIGHT STRUCTURAL CONCRETE:
§ FOOTINGS 3000 PSI
§ SLABS-ON-GRADE 4000 PSI
3. PIPES OR DUCTS SHALL NOT EXCEED ONE-THIRD THE SLAB OR WALL THICKNESS
INCLUDING CROSSING UNLESS SPECIFICALLY DETAILED IN THE STRUCTURAL
DOCUMENTS. ALL PIPES AND DUCTS SHALL BE PLACED IN THE MIDDLE THIRD OF THE
SLAB OR WALL THICKNESS UNLESS SPECIFICALLY DETAILED OTHERWISE IN THE
STRUCTURAL DOCUMENTS. SEE MECHANICAL AND ELECTRICAL DRAWINGS FOR
LOCATION OF SLEEVES, ACCESSORIES, ETC.
4. REFER TO ARCHITECTURAL DRAWINGS FOR MOLDS, GROOVES, ORNAMENTS, CLIPS
OR GROUNDS REQUIRED TO BE ENCASED IN CONCRETE AND FOR LOCATION OF FLOOR
FINISHES AND SLAB DEPRESSIONS.
5. CONSTRUCTION JOINT LOCATIONS SHALL BE APPROVED BY THE DESIGN
PROFESSIONAL. NO HORIZONTAL CONSTRUCTION JOINTS ARE PERMITTED EXCEPT
THOSE SHOWN ON THE STRUCTURAL DRAWINGS.
6. DEFECTIVE AREAS IN CONCRETE INCLUDING, BUT NOT LIMITED TO, HONEY-COMBING,
SPALLS, AND CRACKS WITH WIDTHS EXCEEDING 0.016 INCH SHALL BE REPAIRED. EXTENT
OF DEFECTIVE AREA TO BE DETERMINED BY THE DESIGN PROFESSIONAL.
7. CONCRETE MIX DESIGN FOR CONCRETE SHALL BE BASED ON A MAXIMUM
AGGREGATE SIZE OF 1 IN. MAXIMUM WATER/CEMENT RATIO OF .50 FOR NON-AIR-
ENTRAINED CONCRETE AND .45 FOR AIR-ENTRAINED CONCRETE AND A MAXIMUM SLUMP
OF 4 IN. AIR ENTRAINED CONCRETE SHALL BE USED FOR EXTERIOR EXPOSED
CONCRETE WITH AN AIR CONTENT BETWEEN 3 AND 6 PERCENT.
8. CONCRETE SLABS ON GRADE SHALL NOT BE LOADED UNTIL A MINIMUM CONCRETE
STRENGTH OF 1800 PSI HAS BEEN ATTAINED AND THE CONCRETE IS AT LEAST THREE
DAYS OLD. ALL OTHER CONCRETE MEMBERS SHALL NOT BE LOADED UNTIL THE
SPECIFIED CONCRETE DESIGN STRENGTH HAS BEEN ATTAINED.
9. CONCRETE SHALL BE TESTED IN ACCORDANCE WITH ACI 301 AND THE
SPECIFICATIONS FOR COMPLIANCE WITH THE CONTRACT DOCUMENTS. AT A MINIMUM
CONCRETE SPECIMENS SHALL BE TAKEN FOR EVERY 100 YARDS OR PORTION THEREOF
FOR EACH MIX DESIGN PLACED IN A DAY. CONCRETE TEST REPORTS SHALL BE
AVAILABLE ON SITE FOR INSPECTION.
10. C.J. ON THE SLAB AND FOUNDATION PLAN INDICATES A KEY-FORMED
CONSTRUCTION JOINT OR SAW-CUT CONTROL JOINT IN THE CONCRETE SLAB ON
GRADE. SAW-CUT CONTROL JOINTS SHALL BE INSTALLED WITHIN 12 HOURS OF SLAB
PLACEMENT. CONTINUE REINFORCEMENT THROUGH JOINTS. CONSTRUCTION AND/OR
CONTROL JOINTS SHALL BE SPACED NO FARTHER APART THAN 48 TIMES THE SLAB
THICKNESS OC IN EACH DIRECTION CREATING PANELS WITH AN ASPECT RATIO NOT
GREATER THAN 2:1.
11. UNLESS NOTED OTHERWISE, ALL REINFORCING SHALL BE CONTACT LAP SPLICED
WITH A CLASS B SPLICE IN ACCORDANCE WITH ACI 318. FOR BARS WITH MINIMUM
COVER AND SPACING GREATER THAN 2db AND 3db RESPECTIVELY, THE MINIMUM SPLICE LENGTH OF NOT LESS THAN 48db (db=BAR DIAMETER) SHALL BE USED. SPLICE LENGTHS
SHALL BE INCREASED BY A FACTOR OF 1.3 FOR TOP REINFORCEMENT. LAP WELDED
WIRE FABRIC (WWF) ONE SPACE PLUS 2 IN. ON ALL SIDES AT SPLICES.
12. ALL EXPOSED CORNERS OF CONCRETE SHALL HAVE A CHAMFER OR RADIUS OF 3/4”,
UNLESS NOTED OTHERWISE.
13. CONCRETE SHALL RECEIVE THE FOLLOWING FINISHES:
§ INTERIOR EXPOSED SLABS (UNO OR REQUESTED BY THE OWNER): STEEL TROWEL
FINISH
§ EXTERIOR SLABS: BROOM FINISH IN DIRECTION OF SLOPE
§ ALL OTHER CONCRETE: STEEL TROWEL FINISH
14. MAINTAIN CONCRETE AFTER PLACEMENT WITH MINIMAL MOISTURE LOSS AT
RELATIVELY CONSTANT TEMPERATURE FOR THE PERIOD NECESSARY FOR HYDRATION
OF CEMENT AND HARDENING OF CONCRETE (NOT LESS THAN 7 DAYS). COMPLY WITH
THE REQUIREMENTS OF ACI 308- STANDARD PRACTICE FOR CURING CONCRETE;
AMERICAN CONCRETE INSTITUTE. A COMBINATION CURING AND SEALING COMPOUND
SHALL BE APPLIED AFTER THE CONCRETE HAS BEEN FINISHED OR THE FORMS
REMOVED. COMPOUND SHALL MEET THE REQUIREMENTS OF ASTM C1315.
CONCRETE MASONRY
1. MINIMUM 28-DAY COMPRESSIVE STRENGTH OF CONCRETE MASONRY SHALL BE F'M =
1500 PSI.
2. MORTAR SHALL COMPLY WITH THE BUILDING CODE REQUIREMENTS FOR CONCRETE
MASONRY AND SHALL BE OF THE FOLLOWING TYPE:
§ WALLS TYPE M
3. CONCRETE MASONRY UNITS SHALL BE GROUTED WITH 2500 PSI COARSE GROUT AS
SHOWN IN THE STRUCTURAL DOCUMENTS. GROUT FOR REINFORCED AND
NONREINFORCED MASONRY SHALL CONFORM TO ASTM C476.
4. PROVIDE HORIZONTAL JOINT REINFORCEMENT WITH NO. 9 GAGE LONGITUDINAL
WIRES AT 16" C/C VERTICALLY, UNLESS NOTED OTHERWISE. PROVIDE SPECIAL
ACCESSORIES FOR CORNERS, INTERSECTIONS, ETC.
5. PROVIDE CONTROL JOINTS IN ALL CONCRETE MASONRY WALLS AT LOCATIONS
APPROVED BY THE DESIGN PROFESSIONAL AT A MAXIMUM SPACING OF 3 TIMES THE
WALL HEIGHT OR 40'-0", WHICHEVER IS LESS.
6. PROVIDE DOVETAIL ANCHORS AT 16" C/C, UNLESS NOTED OTHERWISE, WHERE
MASONRY WALLS ABUT CONCRETE SURFACES.
7. SUBMIT WRITTEN CONSTRUCTION PROCEDURES PRIOR TO THE START OF MASONRY
CONSTRUCTION.
8. MINIMUM VERTICAL WALL REINFORCEMENT SHALL BE #5@32" C/C, UNLESS NOTED
OTHERWISE.
STRUCTURAL STEEL
1. STRUCTURAL STEEL SHALL CONFORM TO ASTM A992, UNLESS NOTED OTHERWISE.
§ STRUCTURAL STEEL TUBING SHALL CONFORM TO ASTM A500, GRADE B.
§ STRUCTURAL CHANNELS, MISCELLANEOUS PLATES AND CONNECTION MATERIAL
SHALL CONFORM TO ASTM A36, UNLESS NOTED OTHERWISE.
2. BOLTS AND ANCHORS:
2.1 BOLTED CONNECTIONS SHALL BE TYPE N (BEARING TYPE WITH THREADS INCLUDED
IN SHEAR PLANE) WITH MINIMUM 3/4" DIAMETER (UNO) A325 BOLTS. SUBMIT PROPOSED
BOLT TIGHTENING PROCEDURE FOR REVIEW.
2.2 ANCHOR BOLTS SHALL BE HEADED BOLTS CONFORMING TO ASTM F1554 AND SHALL
BE HEADED RODS OR THREADED RODS WITH HEAVY HEXAGONAL NUT WELDED TO THE
BOTTOM OF THE THREADED ROD, GRADE A36, UNLESS NOTED OTHERWISE.
1.
2.
2.3 EXPANSION ANCHORS SHALL HAVE BEEN EVALUATED BY THE ICC EVALUATION
SERVICES, INC (ICC-ES) WITH A PUBLISHED EVALUATION REPORT. ANCHORS SHALL BE
EVALUATED BY ICC-ES ACCEPTANCE CRITERIA 193 AND BE SPECIFICALLY APPROVED
FOR USE IN CRACKED CONCRETE. CONTACT DESIGN PROFESSIONAL FOR
DETERMINATION OF CRACKED OR UNCRACKED CONCRETE CONDITION UNLESS
CONDITION IS NOTED ON THE DRAWINGS. ALL ANCHORS SHALL BE APPROVED FOR
RESISTING WIND AND SEISMIC LOADS. INSTALL IN ACCORDANCE WITH THE
MANUFACTURER'S RECOMMENDATIONS. MINIMUM EMBEDMENT SHALL BE EQUAL TO 4.5
TIMES THE ANCHOR DIAMETER, UNLESS NOTED OTHERWISE.
2.4 ADHESIVE ANCHORS SHALL CONSIST OF AN ALL-THREAD STEEL ANCHOR WITH
ADHESIVE CONFORMING TO ASTM C881-02, TYPE IV, GRADE 3, CLASS A, B, & C
EXCEPT GEL TIMES AND EPOXY CONTENT. ADHESIVE SHALL CONSIST OF A TWO
COMPONENT ADHESIVE SYSTEM CONTAINED IN SIDE BY SIDE PACKAGING
CONNECTED TO A MIXING NOZZLE WHICH THOROUGHLY MIXES THE COMPONENTS
AS IT IS INJECTED INTO THE HOLE. ADHESIVE SHALL HAVE PASSED ICC EVALUATION
SERVICES, INC ACCEPTANCE CRITERIA 308 FOR LONG TERM CREEP AND BE
SPECIFICALLY APPROVED FOR USE IN CRACKED CONCRETE. INSTALL IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. MINIMUM
EMBEDMENT SHALL BE EQUAL TO 4.5 TIMES THE ANCHOR DIAMETER, UNLESS NOTED
OTHERWISE.
2.4 ANCHOR BOLTS SECURING WOOD PLATES SHALL BE PROVIDED WITH 1/4"x2-1/2"x2
1/2" BEARING PLATE BP 5/8" BY SIMPSON STRONG-TIE COMPANY INC. ANCHOR BOLTS
FOR SILL PLATES SHALL BE EMBEDDED A MINIMUM OF 6 IN. FOR CONCRETE AND 8 IN.
FOR MASONRY.
3. STRUCTURAL STEEL SHALL BE FABRICATED AND ERECTED ACCORDING TO BOTH
THE AISC “SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS” AND THE AISC "CODE OF
STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES".
SUBMIT SHOP DRAWINGS WHICH ADEQUATELY DEPICT THE STRUCTURAL ELEMENTS
AND CONNECTIONS SHOWN IN THE CONTRACT DOCUMENTS. CONNECTIONS SHALL
BE DETAILED BASED ON THE DESIGN INFORMATION PROVIDED IN THE CONTRACT
DOCUMENTS. CONNECTIONS SHALL BE DESIGNED FOR THE SERVICE LOAD
REACTION VALUES SHOWN ON THE STRUCTURAL DRAWINGS. FOR STEEL MEMBERS
WHOSE REACTIONS ARE NOT SHOWN, THE DESIGN REACTION SHALL BE OBTAINED
FROM THE TABLES ENTITLED "MAXIMUM TOTAL UNIFORM LOAD" IN PART 3 OF THE
AISC "MANUAL OF STEEL CONSTRUCTION", FOURTEENTH (14TH) EDITION. THE DESIGN
REACTION IS EQUAL TO HALF THE TABULATED VALUE FOR NONCOMPOSITE BEAMS.
CONNECTIONS SHALL BE DESIGNED FOR THE SERVICE LOAD REACTION OF 10 KIPS
UNLESS SHOWN OTHERWISE ON THE STRUCTURAL DRAWINGS. DEVIATION FROM
THE CONNECTION DETAILS DEPICTED IN THE CONTRACT DOCUMENTS SHALL NOT BE
PERMITTED WITHOUT WRITTEN PERMISSION FROM THE DESIGN PROFESSIONAL.
REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE FULL RESPONSIBILITY FOR
THE DESIGN AND ADEQUACY OF SUCH CONNECTIONS. DESIGN PROFESSIONAL
SHALL BE COMPENSATED BY THE CONTRACTOR FOR THE COST INVOLVED IN THE
REDESIGN OF CONNECTIONS FOR THE CONVENIENCE OF THE CONTRACTOR. STEEL
CONNECTIONS NOT COMPLETELY DETAILED ON THE STRUCTURAL DRAWINGS SHALL
BE DESIGNED BY THE CONTRACTOR. THIS DESIGN SERVICE SHALL BE INCLUDED IN
THE CONTRACTOR'S SCOPE OF SERVICES. SHOP DRAWINGS AND CALCULATIONS
FOR SUCH CONNECTIONS SHALL BE SEALED BY AN ENGINEER LICENSED IN THE
PROJECT STATE. REVIEW DOES NOT RELIEVE THE CONTRACTOR OF THE FULL
RESPONSIBILITY FOR THE DESIGN AND ADEQUACY OF SUCH CONNECTIONS. FOR
CONNECTION DETAILS DEPICTING ARRANGEMENT CONCEPT OF THE CONNECTION
WITHOUT COMPLETE DETAILS, THE CONNECTION DESIGN ENGINEER SHALL FOLLOW
THAT ARRANGEMENT CONCEPT IN THE DESIGN. SINGLE ANGLE CONNECTIONS ARE
NOT ACCEPTABLE.
4. USE PRE-QUALIFIED WELDED JOINTS IN ACCORDANCE WITH AISC AND THE
STRUCTURAL WELDING CODE OF THE AMERICAN WELDING SOCIETY. "NON-PRE-
QUALIFIED JOINTS" SHALL BE QUALIFIED PRIOR TO FABRICATION.
5. STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE GALVANIZED.
METAL DECK
1. DECK DESIGN IS BASED ON THE STEEL DECK INSTITUTE DESIGN MANUAL FOR
COMPOSITE DECKS, FORM DECKS AND ROOF DECKS.
2. PROVIDE ROOF DECK WITH THE FOLLOWING MINIMUM PROPERTIES:
§ 1 1/2 INCH DEPTH (1.5B OR EQUIV)
§ 20 GAGE THICKNESS
§ 0.234 IN3/FT SECTION MODULUS
§ 0.201 IN4/FT MOMENT OF INERTIA
§ 33,000 PSI YIELD STRESS
3. DECK IS SPECIFIED BASED ON A THREE SPAN CONDITION. FURNISH HEAVIER GAGE
DECK IF REQUIRED FOR ONE OR TWO SPAN CONDITIONS.
4. FASTEN ROOF DECK TO RESIST A NET ULTIMATE UPLIFT OF 30 PSF OR AS INDICATED
ON THE DRAWINGS.
5. FASTEN DECK TO RESIST A DIAPHRAGM SHEAR FORCE OF 500 POUNDS PER LINEAR
FOOT.
COLD-FORMED STEEL
1. DESIGN OF COLD-FORMED STEEL STRUCTURAL MEMBERS AND THEIR CONNECTIONS
SHALL BE THE SOLE RESPONSIBILITY OF THE CONTRACTOR. SUBMIT SHOP DRAWINGS
SEALED BY AN ENGINEER LICENSED IN THE PROJECT STATE. REVIEW OF SHOP
DRAWINGS SHALL BE FOR CONFORMANCE WITH THE CONTRACT DOCUMENTS
REGARDING ARRANGEMENT AND SIZES OF MEMBERS AND THE CONTRACTOR'S
INTERPRETATION OF THE DESIGN LOADS AND CONTRACT DOCUMENT DETAILS. SUCH
REVIEW SHALL NOT RELIEVE THE CONTRACTOR OF FULL RESPONSIBILITY FOR THE
DESIGN OF THE COLD-FORMED STEEL STRUCTURAL MEMBERS AND THEIR
CONNECTIONS.
2. COLD-FORMED STEEL DESIGN, FABRICATION AND ERECTION SHALL BE IN
ACCORDANCE WITH AISI "SPECIFICATION FOR DESIGN OF COLD-FORMED STEEL
STRUCTURAL MEMBERS" OR "LOAD AND RESISTANCE FACTOR DESIGN SPECIFICATION
FOR COLD-FORMED STEEL STRUCTURAL MEMBERS".
3. COLD-FORMED STEEL STUDS, JOISTS AND ACCESSORIES SHALL BE AS SHOWN IN
THE STRUCTURAL DOCUMENTS.
4. COLD-FORMED STEEL TRUSSES SHALL BE DESIGNED FOR THE DESIGN LOADS
SHOWN IN THE CONTRACT DOCUMENTS. REFER TO THE SPECIFICATIONS.
5. COLD-FORMED STEEL STRUCTURAL MEMBERS MAY BE ATTACHED BY EITHER WELDS
OR SCREWS SIZED BY THE MANUFACTURER FOR THE SPECIFIED DESIGN LOADS. SEE
THE SPECIFICATIONS.
6. CONTRACTOR SHALL FURNISH COMPLETE FABRICATION AND ERECTION DRAWINGS
FOR APPROVAL BY THE STRUCTURAL ENGINEER PRIOR TO THE COMMENCEMENT OF
FABRICATION. INCLUDE PLACING DRAWINGS FOR FRAMING MEMBERS SHOWING SIZE
AND GAGE DESIGNATIONS, NUMBER, TYPE, LOCATION AND SPACING. INDICATE
SUPPLEMENTAL STRAPPING, BRACING, SPLICES, BRIDGING, ACCESSORIES AND DETAILS
REQUIRED FOR PROPER INSTALLATION.
8. WELDING OF COLD-FORMED STEEL SHALL BE IN ACCORDANCE WITH THE STANDARD
CODE OF ARC AND GAS WELDING IN BUILDING CONSTRUCTION.
§ THE CALCULATED DEFLECTION FOR INDIVIDUAL MEMBERS SUPPORTING MASONRY
DO NOT EXCEED L/600 FOR DESIGN LOADS APPLIED AFTER THE INSTALLATION OF THE
MASONRY.
6. SPECIAL INSPECTIONS:
6.1 THE STRUCTURAL TESTING/INSPECTION AGENCY WILL PERFORM SPECIAL
INSPECTIONS AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE. MATERIALS AND
WORK TO BE INSPECTED INCLUDE STEEL, CONCRETE, AND SOILS CONSTRUCTION. SEE
SCHEDULE OF SPECIAL INSPECTIONS FOR A COMPLETE LIST OF WORK REQUIRING
SPECIAL INSPECTIONS.
6.2 SPECIAL INSPECTION AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE ARE
REQUIRED FOR STRUCTURAL COMPONENTS AND ASSEMBLIES WHICH ARE NOT
FABRICATED AT THE CONSTRUCTION JOB SITE INCLUDING BUT NOT LIMITED TO ROOF
JOISTS OF STEEL MATERIALS, STRUCTURAL STEEL FRAMING, AND CLADDING.
6.3 SPECIAL INSPECTION AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE MAY BE
WAIVED FOR ITEMS WHICH ARE PRODUCED ON THE PREMISES OF A FABRICATOR
REGISTERED AND APPROVED TO PERFORM SUCH WORK WITHOUT SPECIAL INSPECTION.
APPROVAL SHALL BE BASED UPON REVIEW OF THE FABRICATOR'S WRITTEN
PROCEDURAL AND QUALITY CONTROL MANUALS AND BY PERIODIC AUDITING OF
FABRICATION PRACTICES BY AN APPROVED SPECIAL INSPECTION AGENCY. THE
APPROVED FABRICATOR SHALL SUBMIT A CERTIFICATE OF COMPLIANCE TO THE
CONTRACTING OFFICERS REPRESENTATIVE (COR) WHICH STATES THAT THE
FABRICATION WORK WAS PERFORMED IN ACCORDANCE WITH THE APPROVED
CONSTRUCTION DOCUMENTS.
6.4 THE CONTRACTOR WILL EMPLOY ONE OR MORE SPECIAL INSPECTORS TO PERFORM
INSPECTIONS AS REQUIRED BY CHAPTER 17 OF THE BUILDING CODE DURING
CONSTRUCTION OF THE PROJECT. DOCUMENTATION THAT SUMMARIZES THE
QUALIFICATION AND CREDENTIALS OF EACH SPECIAL INSPECTOR AND DEMONSTRATES
COMPETENCE FOR INSPECTION OF EACH PARTICULAR TYPE OF CONSTRUCTION
REQUIRING SPECIAL INSPECTION SHALL BE SUBMITTED TO THE COR FOR REVIEW AND
APPROVAL PRIOR TO CONSTRUCTION.
6.5 APPROVED SPECIAL INSPECTORS SHALL FURNISH INSPECTION REPORTS TO THE
COR AND TO THE DESIGN PROFESSIONAL WHICH INDICATE THAT THE WORK INSPECTED
WAS DONE IN CONFORMANCE WITH THE APPROVED CONSTRUCTION DOCUMENTS. A
FINAL REPORT WHICH DOCUMENTS THE RESULTS OF THE SPECIAL INSPECTIONS
PERFORMED INCLUDING CORRECTION OF ANY DISCREPANCIES IDENTIFIED DURING
INSPECTION SHALL BE SUBMITTED PERIODICALLY AT A FREQUENCY APPROVED BY COR
PRIOR TO CONSTRUCTION.
7. NO PROVISIONS HAVE BEEN MADE FOR FUTURE HORIZONTAL OR VERTICAL
EXPANSION.
DocuSign Envelope ID: 40DD75DE-DBB5-4FFF-BC8A-F83F89EE99A4
7/28/2023
NOTES:
1. SEE S-001 FOR STRUCTURAL GENERAL NOTES.
2. SEE ARCH FOR ADDITIONAL INFORMATION AND
DIMENSIONS.
3. Fx INDICATES COLUMN FOOTING. SEE
T/FTG = -3'-0" UNO, BASED ON T/SLAB REFERENCE
ELEVATION = 0'-0".
4. BPx INDICATES COLUMN BASE PLATE.
SEE .
5. T/SLAB EL = 0'-0". PROVIDE 4" SLAB ON GRADE
REINFORCED WITH WWF 6x6 W2.1xW2.1 ON VAPOR
BARRIER AND 4" GRANULAR BASE.
6. C.J. INDICATES SLAB CONTROL JOINT. SEE
AND GENERAL NOTES FOR ADDITIONAL
INFORMATION.
7. ISOLATION JOINT AT COLUMN. SEE
8. PROVIDE REINFORCEMENT AT RE-ENTRANT
CORNERS, SEE
9. INDICATES MASONRY WALL REINFORCED
W/ #5 @ 32" O.C., SEE DETAIL
10. INDICATES MASONRY WALL
REINFORCEMENT, SEE DETAILS
11. CONTRACTOR SHALL BE RESPONSIBLE FOR
COORDINATION OF ALL UTILITY AND PLUMBING
LINES. SEE
X
/1 S-301
/5 S-501
/12 S-301
/16 S-301
/20 S-301
/4 S-401
/1 S-401
/9 S-301
A
B
F4.
H
SS8X
8X 1/
F4.
H
SS8X
8X 1/
F4.
H
SS8X
8X 1/
F4.0
H
SS8X8X1/4
F4.
H
SS8X
8X 1/
F4.
H
SS8X
8X 1/
F4.
H
SS8X
8X 1/
S-301
1 2 3
SLAB ON GRADE
SEE NOTE 5
S-301
S-301
6' - 6 7/8"
C.J. TYP.
SEE NOTE 6
BP1
BP1
BP1
BP1
BP1
BP1
A
A A
A
A
C
C C
C
NOTE 8
TYP
S-301
S-301
C
C C
C
C
C C
C C
C C
C
61' - 10"
1' - 10 7/8" 4' - 9 1/8" 1' - 5 1/8"
1' - 5 1/8" 4' - 9 1/8" 1' - 3" 3' - 5" 10' - 0"
/8
/8
/8
/8
BP1
9' - 1" 39' - 4" 13' - 5"
6' - 8"
F4.
H
SS8X
8X 1/
BP1
# KEY NOTES:
Dwg of
SHEET NOTES:
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 003
S-101
FOUNDATION PLAN - SHELTER
BUILDING
JC/HHJW 178 186JULY 28, 2023
BID DOCUMENTS
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
AE DESIGN SERVICES
1/4" = 1'-0"S-101
1 FOUNDATION PLAN
A
B
1 2 3
S-501
S-501
W12X19
W X
W X
W12X19
W12X19
W12X19
CANT.
CANT.
S-501
W12X19
W X
W X
W12X19
W X
W X
W12X19
T
T
T
T
T
T
T
T
T
T
T2A
T2A
T2
T2
T1
T1
T
T
T
T A T3
T3
29' - 4" 9' - 10"
4' - 8" 20' - 0" 4' - 8" 6' - 9" 3' - 1"
NOTES:
1. SEE S-001 FOR STRUCTURAL GENERAL NOTES.
2. SEE ARCH FOR ADDITIONAL INFORMATION AND
DIMENSIONS.
3. DECK BEARING ELEVATION RELATIVE TO FIRST
FLOOR REFERENCE ELEVATION = 0'-0" UNO.
4. INDICATES DIRECTIONAL SPAN OF 1 1/2" x 20
GA GALV. ROOF DECK, SEE
5. INDICATES MOMENT CONNECTION. SEE
6. TX INDICATES COLD-FORMED STEEL TRUSS SPACED
AT 3'-0" MAX. TRUSS BEARING EL = 9'-9". SEE 17/S-501
FOR TRUSS PROFILES.
/12 S-501
/9 S-501
# KEY NOTES:
Dwg of
SHEET NOTES:
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 003
S-201
ROOF FRAMING PLAN - SHELTER
BUILDING
JC/HHJW 179 186JULY 28, 2023
BID DOCUMENTS
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
AE DESIGN SERVICES
1/4" = 1'-0"S-201
1 ROOF FRAMING PLAN
FOOTING SCHEDULE
MARK SIZE (WxLxT) REINF
F4.0 4#54'-0"x4'-0"x18"
REMARKS
T&B
T/SLAB EL
FIN GRADE
ISOLATION JOINT
T/FTG EL
COLUMN, SEE PLAN
SEE ARCH
CONCRETE FOOTING,
SEE PLAN
SEE FOR BASE
PLATE & ANCHOR
BOLT DTL/SCHED
G R
O U
T
T
IE
S P
A C
IN
G
T/PEDESTAL EL
LEAN CONCRETE FILL TO
BOTTOM OF ELEVATION
/5 S-501
NOTES:
1. ELEVATION PER GEOTECHNICAL REPORT APPROX. 9'-0" BELOW FFE.
FILL EL
SEE NOTE 1
F T
G
W A
L L
M
IN
F T
G T
H
IC
K N
E S
S 1' - 6" 1' - 6"
2' - 8" 2' - 8"
CL OF PIPE
PIPE NEAR TOP OF FOOTING
2' - 0" 2' - 0"
M
IN3
ADDL REINF TO
MATCH FTG REINF
FTG REINF
#6 @ 12" OC
T/FTG EL
F T
G
W A
L L
M
IN
F T
G T
H
IC
K N
E S
S 1' - 6" 1' - 6"
CL OF PIPE
PIPE AT BOTTOM OF FOOTING
2' - 0" 2' - 0"
M
IN3
ADDL REINF TO
MATCH FTG REINF
FTG REINF
T/FTG EL
F T
G
W A
L L
CL OF PIPE
PIPE UNDER FOOTING
FTG REINF
T/FTG EL
M
IN6
NOTE:
VERIFY PIPE PENETRATION LOCATION
WITH PLUMBING CONTRACTOR
#6 @ 12" OC
2' - 8" 2' - 8"
1/8" x 1/3 SLAB DEPTH
SAW CUT JOINT
SLAB REINFORCEMENT IN
TOP 1/3 OF SLAB
CONTRACTION JOINT
TOOLED JOINT
SLAB REINFORCEMENT IN
TOP 1/3 OF SLAB
CONSTRUCTION JOINT
NOTE: SAW CUT OR DISCONTINUE
REINFORCEMENT AT CONTRACTION JOINT
3" 2"
BUILDING CORNER OR
CONSTRUCTION JOINT
2#5 x 4'-0" LONG TOP
EDGE OF SLAB
BASE PLATE, TYP.
SEE NOTE 1
ISOLATION JOINT, TYP.
CONTRACTION JOINT
OR CONSTRUCTION
JOINT, TYP.
ISOLATION JOINT, TYP.
EDGE OF SLAB
EDGE OF
SLAB
COLUMN, SEE PLAN
TYP.
C
LR
3" C
LR
3"
C
LR
3"
NOTE
1. COORDINATE ISOLATION JOINT
SIZE WITH BASEPLATE
SCHEDULE, SEE 5/S5.0.
C L R
1' - 6"
T/SLAB EL
WWF
F R
O S
T D
E P
T H
M
IN
#4 @ 12" O.C.
3'-0"
4#5 CONT
1/2" EXP JT
SEE CIVIL
1' - 6"
T/SLAB EL
WWF
#4 @ 12" O.C.
3'-0"
4#5 CONT
CMU WALL
6"
#5 DOWELS @ 32" O.C. W/ STD
90 HOOK ALTERNATE HOOKS
T/SLAB EL
WWF
6"
2#5 CONT BOT 2
NON-BEARING WALLS
T/SLAB EL
CONT WWF BENEATH CONDUIT, MATCH
GRADE SUPPORTED SLAB REINF
6"
WWF
CONDUIT
3d
C L R
TYP
4"
C L R
NOTE:
d = OUTSIDE DIAMETER OF CONDUIT
FOOTING LINE
OF INFLUENCE
DROP TURNDOWN AS REQUIRED
TO KEEP EXCAVATION OUT OF
FOOTING LINE OF INFLUENCE
FIN GRADE
BACKFILL TRENCH PER
GEOTECHNICAL
REQUIREMENTS
1' - 6"
T/SLAB EL
WWF
#4 @ 12" O.C.
3'-0"
4#5 CONT
#5 CONT
NON-BEARING WALLS
CMU WALL
#5 DOWELS @ 32" O.C. W/ STD
90 HOOK ALTERNATE HOOKS
T/SLAB EL
WWF
2#5 CONT BOT 2
T/SLAB EL
ISOLATION JOINT
T/FTG EL
COLUMN, SEE PLAN
CONCRETE FOOTING,
SEE PLAN
SEE FOR BASE
PLATE & ANCHOR
BOLT DTL/SCHED
G R
O U
T
T
IE
S P
A C
IN
G
T/PEDESTAL EL
LEAN CONCRETE FILL TO
BOTTOM OF ELEVATION
/5 S-501
NOTES:
1. ELEVATION PER GEOTECHNICAL REPORT APPROX. 9'-0" BELOW FFE.
T/SLAB EL
FILL EL
SEE NOTE 1
Dwg of
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .