This document provides specifications for door hardware required for a federal construction project. The project involves replacing the committal shelter and repairing roads at Dayton National Cemetery, solicited by the Department of Veterans Affairs National Cemetery Administration under solicitation number 36C78623B0033. Hardware requirements include butts and hinges, continuous hinges, door closers, door stops, locks and latches, exit devices, flush bolts, door pulls, push plates, thresholds, weatherstripping, and finishes. Hardware sets are defined for administration building entrances, telecom and electrical rooms, building interiors, maintenance and storage areas, offices, storage rooms, and toilets. Installation standards are also provided.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
PIC/ADMIN BLDG REPLACE COMMITTAL JULY 28, 2023 REVISED SEPTEMBER 13, 2023
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 1
SECTION 08 71 00
DOOR HARDWARE
PART 1 - GENERAL
1.1 DESCRIPTION
A. Door hardware and related items necessary for complete installation and operation of doors.
1.2 RELATED WORK
A. Caulking: Section 07 92 00, JOINT SEALANTS.
B. Application of Hardware: Section 08 14 00, INTERIOR WOOD DOORS
Section 08 11 13, HOLLOW METAL DOORS AND FRAMES Section 08 41 13, ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS , LOW ENERGY POWER ASSIST
DOOR OPERATORS .
C. Finishes: Section 09 06 00, SCHEDULE FOR FINISHES.
D. Painting: Section 09 91 00, PAINTING.
E. Card Readers: Section 28 13 00, PHYSICAL ACCESS CONTROL SYSTEMS (PACS).
F. Electrical: Division 26, ELECTRICAL.
1.3 GENERAL
A. All hardware must comply with UFAS, (Uniform Federal Accessible
Standards) unless specified otherwise.
B. Provide rated door hardware assemblies where required by most current version of the International Building Code (IBC).
C. Hardware for Labeled Fire Doors and Exit Doors: Conform to requirements of NFPA 80 for labeled fire doors and to NFPA 101 for exit doors, as well as to other requirements specified. Provide hardware listed by UL, except where heavier materials, large size, or better grades are specified herein under paragraph HARDWARE SETS. Instead of UL labeling and listing, test reports from a nationally recognized testing agency may be submitted showing that hardware has been tested in accordance with UL test methods and that it conforms to NFPA requirements.
D. Make hardware for application on metal and wood doors and frames to standard templates. Furnish templates to the fabricator of these items in sufficient time so as not to delay the construction.
E. The following items to be of the same manufacturer, if possible, except as otherwise specified:
1. Mortise locksets.
2. Hinges for hollow metal and wood doors.
3. Surface applied overhead door closers.
4. Exit devices.
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 2
1.4 SUSTAINABILITY REQUIREMENTS
A. Materials in this section may contribute towards contract compliance with sustainability requirements. See Section 01 81 11, SUSTAINABLE
DESIGN REQUIRMENTS, for project local/regional materials, low-emitting materials, recycled content, requirements.
1.5 SUBMITTALS
A. Submit in accordance with Section 01 33 23, SHOP DRAWINGS, PRODUCT DATA
AND SAMPLES.
B. Hardware Schedule: Prepare and submit hardware schedule in the following form:
Hardware Item
Quantity Size Reference Publication Type No.
Finish Mfr. Name and Catalog
No.
Key Control Symbols
UL Mark (if fire rated and listed)
ANSI/BHMA
Finish
Designation
C. Samples and Manufacturers' Literature:
1. Samples: All hardware items (proposed for the project) that have not been previously approved by Builders Hardware Manufacturers
Association must be submitted for approval. Tag and mark all items with manufacturer's name, catalog number and project number.
2. Samples are not required for hardware listed in the specifications by manufacturer's catalog number, if the contractor proposes to use the manufacturer's product specified.
D. Certificate of Compliance and Test Reports: Submit certificates that hardware conforms to the requirements specified herein. Certificates must be accompanied by copies of reports as referenced. The testing must have been conducted in the manufacturer's plant and certified by an independent testing laboratory or conducted in an independent laboratory, within four years of submittal of reports for approval.
1.6 DELIVERY AND MARKING
A. Deliver items of hardware to job site in their original containers, complete with necessary appurtenances including screws, keys, and instructions. Tag one of each different item of hardware and deliver to
RE/COR for reference purposes. Tag must identify items by Project
Specification number and manufacturer's catalog number. These items
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 3 will remain on file in RE/COR's office until all other similar items have been installed in the project, at which time the RE/COR will deliver items on file to Contractor for installation in predetermined locations on the project.
1.7 INSTRUCTIONS
A. Hardware Set Symbols on Drawings: Except for protective plates, door stops, mutes, thresholds and the like specified herein, hardware requirements for each door are indicated on drawings by symbols.
Symbols for hardware sets consist of the letters "HW" followed by a number. Each number designates a set of hardware items applicable to a door type.
B. Keying: Key cylinders into existing ___________ Great Grand Master
Key System . Provide removable core cylinders that are removable only with a special key or tool without disassembly of knob or lockset.
Provide 6 7 pin type cylinders. Keying information will be furnished at a later date by the RE/COR.
C. Keying: Establish a new Great Grandmaster key for this project. Provide removable core type key system as previously described. The manufacturer must furnish code pattern listings so keys may be reproduced by code. Design the new key system with the capacity to relock the existing station and also provide for 25 percent expansion capability beyond this requirement. Submit a keying chart for approval showing proposed keying layout and listing expansion capacity.
1. Keying information will be furnished to the Contractor by the
RE/COR.
2. Supply information regarding key control of cylinder locks to manufacturers of equipment having cylinder type locks. Notify RE/COR immediately when and to whom keys or keying information is supplied.
Return all such keys to the RE/COR.
1.8 APPLICABLE PUBLICATIONS
A. Publications listed below form a part of this specification to the extent referenced. Publications are referenced in text by the basic designation only. Comply with applicable provisions and recommendations of the following, except as otherwise shown or specified.
B. American National Standards Institute/Builders Hardware Manufacturers
Association (ANSI/BHMA):
A156.1-13 Butts and Hinges
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 4
A156.2-11 Bored and Pre-assembled Locks and Latches
A156.3-01 Exit Devices
A156.4-08 Door Controls (Closers)
A156.5-10 Auxiliary Locks and Associated Products
A156.6-10 Architectural Door Trim
A156.8-10 Door Controls-Overhead Stops and Holders
A156.13-12 Mortise Locks and Latches
A156.15-11 Release Devices-Closer Holder, Electromagnetic and Electromechanical
A156.16-02 American National Standard for Auxiliary
Hardware
A156.18-12 Materials and Finishes
A156.21-09 Thresholds
A156.22-12 Door Gasketing and Edge Seal Systems
A156.23-10 Electromagnetic Locks
A156.24-12 Delayed Egress Locking Systems
A156.26-12 Continuous Hinges
A156.31-01 Electric Strikes and Frame Mounted Actuators
C. American Society for Testing and Materials (ASTM):
F883-09 Padlocks
D. Builders Hardware Manufacturers Association (BHMA):
Certified Products Directory 2014
E. National Fire Protection Association (NFPA):
80-13 Fire Doors and Fire Windows
101-12 Life Safety Code
F. Underwriters Laboratories, Inc. (UL):
Building Materials Directory
PART 2 - PRODUCTS
2.1 BUTT HINGES
A. ANSI A156.1. Provide the following types of butt hinges for the types of doors listed, except where otherwise specified:
1. Exterior Doors: Type A2112 for doors 900 mm (3 feet) wide or less and Type A2111 for doors over 900 mm (3 feet) wide. Provide hinges for exterior doors with non-removable pins.
2. Interior Doors: Type 8112 for doors 900 mm (3 feet) wide or less and
Type A8111 for doors over 900 mm (3 feet) wide.
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 5
B. See Articles "MISCELLANEOUS HARDWARE" and "HARDWARE SETS" for pivots and hinges other than butts specified above and continuous hinges specified below.
2.2 CONTINUOUS HINGES
A. Continuous, Gear-Type Hinges: Extruded-aluminum, pin-less, geared hinge leaves; joined by a continuous extruded-aluminum channel cap; with concealed, self-lubricating thrust bearings.
B. ANSI/BHMA A156.26, Grade 1-600.
1. Listed under Category N in BHMA's "Certified Product Directory."
2.3 DOOR CLOSING DEVICES
A. Provide closing devices of one manufacturer for each type specified.
2.4 OVERHEAD CLOSERS
A. Conform to ANSI A156.4, Grade 1 and the following:
1. 50 percent adjustable closing force over minimum value for that closer and have adjustable hydraulic back check effective between 60 degrees and 85 degrees of door opening.
2. Hold-open feature, where specified.
3. Size Requirements: Size closers in accordance with manufacturer’s recommendations or provide multi-size closers, sizes 1 through 6.
4. Material of closer must be cast aluminum.
5. Steel or malleable iron arm and brackets.
6. Provide full size cover.
7. Adjustable hydraulic back-check and separate valves for closing and latching speed.
2.5 DOOR STOPS
A. Conform to ANSI A156.16.
B. Provide door stops wherever an opened door or any item of hardware thereon would strike a wall, column, equipment or other parts of building construction. For concrete, masonry or quarry tile construction, use lead expansion shields for mounting door stops.
C. Where cylindrical locks with turn pieces or pushbuttons occur, equip wall bumpers Type L02251 (rubber pads having concave face) to receive turn piece or button.
D. Substitute floor stops Type L02141 or L02161 as appropriate, when wall bumpers would not provide an effective door stop.
E. Where drywall partitions occur, use floor stops, Type L02141 or L02161.
F. Provide stop Type L02011 or L02181, as applicable for exterior doors.
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 6
G. Provide appropriate roller bumper for each set of doors (except where closet doors occur) where two doors would interfere with each other in swinging.
H. Provide appropriate door mounted stop on doors in individual toilets where floor or wall mounted stops cannot be used.
2.6 LOCKS AND LATCHES
A. Conform to ANSI A156.2. Locks and latches for doors 45 mm (1-3/4 inch) thick or over must have beveled fronts. Lock cylinders must have not less than six pins seven pins . Cylinders for all locksets to be removable core type. Provide cylinders with construction removable cores and construction master keys. Cylinder to be removable by special key or tool. Construct all cores so that they will be interchangeable into the core housings of all mortise locks, rim locks, cylindrical locks, and any other type lock included in the Great Grand
Master Key System. The lever or lockset must not require disassembly to remove core from lockset. All locksets or latches on double doors with fire label to have latch bolt with 19 mm (3/4 inch) throw. Provide temporary keying device or construction core of allow opening and closing during construction and prior to the installation of final cores.
B. In addition, locks and latches must comply with following requirements:
1. Mortise Lock and Latch Sets: Conform to ANSI/BHMA A156.13; Series
1000, minimum Grade 2. Locks and latchsets to be furnished with curved lip strike and wrought box. Lock function F02 to be furnished with emergency tools/keys for emergency entrance. Furnish armored fronts for all mortise locks. Where mortise locks are installed in high-humidity locations or where exposed to the exterior on both sides of the opening, provide non-ferrous mortise lock case.
2. Cylindrical Lock and Latch Sets: Levers must meet ADA (Americans with Disabilities Act) requirements. Cylindrical locksets to be series 4000 Grade I. Knobs for series 4000 lock and latch sets to have 57 mm (2-1/4 inch) diameters. Where two turn pieces are specified for lock F76, turn piece on inside knob must lock and unlock inside knob, and turn piece on outside knob must unlock outside knob when inside knob is in the locked position. (This function is intended to allow emergency entry into these rooms without an emergency key or any special tool.)
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 7
3. Auxiliary locks specified under hardware sets must conform to ANSI
A156.5.
2.7 ELECTROMAGNETIC LOCKS
A. ANSI/BHMA A156.23; electrically powered, of strength and configuration indicated; with electromagnet attached to frame and armature plate attached to door. Listed under Category E in BHMA's "Certified Product
Directory."
1. Type: Full exterior or full interior, as required by application indicated.
2. Strength Ranking: 1500 lbf 1000 lbf 500 lbf.
3. Inductive Kickback Peak Voltage: Not more than 53 0 V.
4. Residual Magnetism: Not more than 4 lbf 0 lbf to separate door from magnet.
B. Delayed-Egress Locks: BHMA A156.24. Listed under Category G in BHMA's
"Certified Product Directory".
1. Means of Egress Doors: Lock releases within 15 seconds after applying a force not more than 15 lbf for not more than 3 seconds, as required by NFPA 101.
2. Security Grade: Activated from secure side of door by initiating device.
3. Movement Grade: Activated by door movement as initiating device.
4. Lock housing must not project more than 4-inches (101mm) from the underside of the frame head stop.
2.8 ELECTRIC STRIKES
A. ANSI/ BHMA A156.31 Grade 1.
B. General: Use fail-secure electric strikes at fire-rated doors.
2.9 KEYS
A. Stamp all keys with change number and key set symbol. Furnish keys in quantities as follows:
Locks/Keys Quantity
Cylinder locks 2 keys each
Cylinder lock change key blanks
10 each different key way
Master-keyed sets 6 keys each
Grand Master sets 6 keys each
Great Grand Master set 5 keys
Control key 1 key
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 8
2.10 KICK-MOP PLATES
A. Conform to ANSI Standard A156.6.
B. Provide protective plates and door edging as specified below:
1. Kick-mop plates and armor plates to be metal, Type J100 series, color as required.
2. Provide kick-mop plates for both sides of each new door, except where noted as not required. Kick-mop plates to be 200 mm (8 inches) high. On push side of doors where jamb stop extends to floor, make combination kick-mop plates 38 mm (1-1/2 inches) less than width of door, except pairs of metal doors to have plates 25 mm (1 inch) less than width of each door. Extend all other combination kick-mop plates to within 6 mm (1/4 inch) of each edge of doors. Kick mop plates to butt astragals. For jamb stop requirements, see specification sections pertaining to door frames.
3. Kick-mop plates are not required on following door sides:
a. Exterior side of exterior doors;
b. Closet side of closet doors;
c. Storage side of doors to or from storage spaces; and
d. Both sides of aluminum entrance doors.
2.11 EXIT DEVICES
A. Conform to ANSI Standard A156.3, Grade 1; type and function are specified in hardware sets. Provide flush with finished floor strikes for vertical rod exit devices in interior of building. Trim to have lever handles similar to locksets, unless otherwise specified.
B. Exit devices for fire doors must comply with Underwriters Laboratories, Inc., requirements for Fire Exit Hardware. Submit proof of compliance.
2.12 FLUSH BOLTS (LEVER EXTENSION)
A. Conform to ANSI A156.16, Type L24081 unless otherwise specified.
Furnish proper dustproof strikes conforming to ANSI A156.16, for flush bolts required on lower part of doors. Modify flush bolts to fit stiles of aluminum doors on double-acting doors.
B. Face plates for cylindrical strikes to be rectangular and not less than
25 mm by 63 mm (1 inch by 2-1/2 inches).
C. Friction-fit cylindrical dustproof strikes with circular face plate may be used only where metal thresholds occur.
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 9
2.13 DOOR PULLS WITH PLATES
A. Conform to ANSI A156.6. Pull plate 90 mm by 350 mm (3-1/2 inches by 14 inches), unless otherwise specified. Cut plates of door pulls for cylinders, or turn pieces where required.
2.14 PUSH PLATES
A. Conform to ANSI A156.6. Metal, Type J302, 200 mm (8 inches) wide by 350 mm (14 inches) high. Provide plastic Type J302 plates 100 mm (4 inches wide by 350 mm (14 inches) high) where push plates are specified for doors with stiles less than 200 mm (8 inches) wide. Cut plates for cylinders, and turn pieces where required.
2.15 COMBINATION PUSH AND PULL PLATES
A. Conform to ANSI 156.6, Type J303; stainless steel 3 mm (1/8 inch) thick, 80 mm (3-1/3 inches) wide by 800 mm (16 inches) high), rounded top and bottom edges. Secure plates to wood doors with 38 mm (1-1/2 inch) long No. 12 wood screws. Cut plates for turn pieces, and cylinders where required. Mount pull in down direction.
2.16 THRESHOLDS
A. Conform to ANSI A156.21, mill finish extruded aluminum, except as otherwise specified. In existing construction, install thresholds in a bed of sealant with machine screws and expansion shields. In new construction, embed aluminum anchors coated with epoxy in concrete to secure thresholds. Furnish thresholds for the full width of the openings.
B. At exterior doors and any interior doors exposed to moisture, provide threshold with non-slip abrasive finish.
2.17 WEATHERSTRIPS (FOR EXTERIOR DOORS)
A. Conform to ANSI A156.22. Air leakage must not to exceed 0.50 CFM per foot of crack length (0.000774m3/s/m).
2.18 FINISHES
A. Exposed surfaces of hardware to have ANSI A156.18 finishes as specified below. Provide finishes on all hinges, pivots, closers, thresholds, etc. as specified below under "Miscellaneous Finishes." For field painting (final coat) of ferrous hardware, see Section 09 91 00, PAINTING.
B. 626 or 630: Surfaces on exterior and interior of buildings, except where other finishes are specified.
C. Miscellaneous Finishes:
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 10
1. Hinges - Exterior Doors: 626 or 630.
2. Hinges - Interior Doors: 652 at rated doors or 626.
3. Door Closers: Factory applied paint finish. Dull or Satin Aluminum color Dull Brass color Bronze color.
4. Thresholds: Mill finish aluminum.
5. Other primed steel hardware: 652.
D. Hardware Finishes for Existing Buildings: Match finishes of hardware in
(similar) existing spaces except where otherwise specified.
2.19 BASE METALS
A. Apply specified U.S. Standard finishes on different base metals as following:
Finish Base Metal
652 Steel
626 Brass or bronze
630 Stainless steel
PART 3 - EXECUTION
3.1 HARDWARE HEIGHTS
A. For existing buildings locate hardware on doors at heights to match existing hardware. Visit the site, verify location of existing hardware and submit locations to RE/COR for approval.
A. For new buildings locate hardware on doors at heights specified below unless otherwise noted:
B. Hardware Heights from Finished Floor:
1. Exit devices centerline of strike (where applicable): 1000 mm
(40-5/16 inches).
2. Locksets and latch sets centerline of strike: 1000 mm (40-5/16 inches).
3. Deadlocks centerline of strike: 1200 mm (48 inches).
4. Centerline of door pulls: 1000 mm (40 inches).
5. Push plates and push-pull: 1250 mm (50 inches) to top of plate.
6. Push-pull latch: 1000 mm (40-5/16 inches) to centerline of strike.
7. Centerline of deadlock strike: 840 mm (33 inches) when used with push-pull latch.
8. Locate other hardware at standard commercial heights.
9. Locate push and pull plates to prevent conflict with other hardware.
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 11
3.2 INSTALLATION
A. Equip and mount closer devices, including those with hold-open features, to provide maximum door opening permitted by building construction or equipment. Closers to be mounted regular arm. Where closers are mounted on doors, mount with sex nuts and bolts; foot fastened to frame with machine screws.
B. Substitute parallel arm or top jamb mounting for regular arm mounting where the following conditions occur:
1. Where door swing, in full open position, would be limited to less than 90 degrees due to partition construction and closer location.
2. Where door to room opens outward into corridor.
3. Where exterior doors open outward.
C. Hinge Size Requirements:
Door Thickness Door Width Hinge Height
45 mm (1-3/4 inch) 900 mm (3 feet) and less 113 mm (4-1/2 inches) 45 mm (1-3/4 inch) Over 900 mm (3 feet) but not more than 1200 mm (4 feet)
125 mm (5 inches)
35 mm (1-3/8 inch) (hollow core wood doors)
Not over 1200 mm (4 feet) 113 mm (4-1/2 inches)
D. Provide hinge leaves sufficiently wide to allow doors to swing clear of door frame trim.
E. Where new hinges are specified for new doors in existing frames or existing doors in new frames, provide sizes of new hinges matching sizes of existing hinges; or, contractor may reuse existing hinges provided hinges are restored to satisfactory operating condition as approved by RE/COR. Existing hinges cannot be reused on door openings having new doors and new frames. Coordinate preparation for hinge cut-outs and screw-hole locations on doors and frames.
F. Hinges Required Per Door:
Doors 1500 mm (5 ft) or less in height 2 butts
Doors over 1500 mm (5 ft) high and not over 2280 mm (7 ft 6 in) high
3 butts
Doors over 2280 mm (7 feet 6 inches) high 4 butts
Dutch type doors 4 butts
Doors with spring hinges 1370 mm (4 feet 6 inches) high 2 butts
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 12 or less
Doors with spring hinges over 1370 mm (4 feet 6 inches) 3 butts
G. Fastenings: Suitable size and type to suit with hardware as to material and finish. Provide machine screws and lead expansion shields to secure hardware to concrete, ceramic or quarry floor tile, or solid masonry.
Fiber or rawl plugs and adhesives are not permitted. All fastenings exposed to weather must be of nonferrous metal.
H. After locks have been installed; show in presence of RE/COR that keys operate their respective locks in accordance with keying requirements.
(Send keys, Master Key level and above by Registered Mail to the
Cemetery Director along with the bitting list. Also send a copy of the invoice to the RE/COR for the records.) Installation of locks which do not meet specified keying requirements will be considered sufficient justification for rejection and replacement of all locks installed on project.
3.3 FINAL INSPECTION
A. Installer to provide letter to RE/COR that upon completion, installer has visited the Project and has accomplished the following:
1. Re-adjust hardware.
2. Evaluate maintenance procedures and recommend changes or additions, and instruct VA personnel.
3. Identify items that have deteriorated or failed.
4. Submit written report identifying problems.
3.4 HARDWARE SETS
A. Following sets of hardware correspond to hardware symbols shown on drawings. Where hardware set for a single door is specified for a pair of doors; equip each leaf of such pair of doors with set noted. Only those hardware sets that are shown on drawings will be required.
Disregard hardware sets listed in specifications but not shown on drawings.
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 13
HARDWARE SETS – ADMINISTRATION BUILDING
HW 1 (Public Entrance and Exit)
Lockset (F04) Power Operator
Continuous Hinge or Pivots
Magnetic Lock
Normal Daytime Operation:
Power operated doors (swinging or horizontal sliding) Door activated by motion sensor on interior and exterior
After Hours Operation:
Power operated doors (swinging or horizontal sliding) Door activated from exterior by card reader or remote release Door activated by motion sensor on interior
HW 2 (Telecom Rms, Elect Closets and IT Service Closets)
Lockset (F07)
Card Reader Continuous Hinge
Flush Bolts
Mortise Lock
Operation at all Times:
Outside lever always rigid Latchbolt released by key outside and lever inside
HW 2A (Telecom Rms, Elect Closets and IT Service Closets)Pair doors
Lockset (F07)
Card Reader Continuous Hinge
Flush Bolts
Mortise Lock
Electric Strike
Operation at all Times:
Outside lever always rigid Latchbolt released by key outside and lever inside
HW 3 (Lobby to Building Interior)
Lockset (F04) Card Reader
Closer
Continuous Hinge Electric Strike
Flush Bolts
Mortise Lock
Operation at all Times:
Outside lever always rigid Card reader releases electric strike Inside lever retracts latchbolt at all times
DAYTON NATIONAL CEMETERY PROJECT NO. 810CM3030
SHELTER B AND ROAD REPAIRS BID DOCUMENTS
DOOR HARDWARE
08 71 00 - 14
HARDWARE SETS – MAINTENANCE/STORAGE BUILDING
HW 4 (Records Stor Closet, incl
FAX)
Lockset (F07)
Card Reader Closer
Continuous Hinge
Electric Strike Flush Bolts
Mortise Lock
Operation at all Times:
Outside lever always rigid Card reader releases electric strike Inside lever retracts latchbolt at all times
HW 7 (Equip and Supply Stor Rms)Pair Doors
Lockset (F07)
Continuous Hinge Flush Bolts
Mortise Lock
Operation at all Times:
Outside lever always rigid Latchbolt released from outside by combination lock
Inside lever retracts latchbolt at all times
HW-26 (Staff Access)
Push Pull
Closer
Hinges
HW 7E
Same as 7 but add threshold and gaskets, due to this being an exterior door.
HARDWARE SETS - MISCELLANEOUS
HW 11 (Office)
Lockset (F04) Cylinder Butts as required Stop Silencers
HW 12 (Storage)
Lockset (F07) Cylinder Butts as required Stop Silencers
HW 13 (Toilet – Privacy)
Lockset (F19) with accessible thumbturn Cylinder Butts as required Stop Silencers
Mop Plate (Interior)
HW-26 (Staff Access)
Push
Pull
Closer Hinges
- - - E N D - - -