S02_Attachment - DNC-810CM3030_Submission_BD_Revised Plan Sheets_Amendment 002.pdf
PDF 6 MB Posted
- Solicitation number
- 36C78623B0033
About this file
This package includes construction documents for renovations at the Dayton National Cemetery. The project involves upgrades to the administration building, replacing committal shelter B, and repairing roads. Key work includes installing new finishes, casework, signage and accessibility features in the administration and honor guard buildings. Site utilities will be improved with stormwater management upgrades and connecting to existing water and sewer lines. A new prefabricated storage shelter will be constructed. The project is solicited under solicitation number 36C78623B0033 issued by the Department of Veterans Affairs National Cemetery Administration.
View the file
Other files
Show all 25
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1.1
A.1
A.8
C.9
2.1 2.9
EQ EQ
E Q
E Q
EQ 5'-0" EQ
EXPOSED CEILING
ALUM. SOFFIT
MEN'S
WOMEN'S
HAC
CORRIDOR
MECH./ ELEC.
STAFF TOILET
STAFF TOILET
LUNCH ROOM
STORAGE
CONFERENCE
ROOM
TR
RECORDS
STORAGE
LOBBY
OFFICE
DIRECTOR'S
OFFICE
WORK
STATIONS
OPERATIONS
CORRIDOR
CORRIDOR
RECEPTION
STORAGE
CORRIDOR
1'-4"
BREEZEWAY
A.0
OFFICE
101A
GRAVE
LOCATOR RM.
9' - 6"
METAL
PANEL
10'-4"
ALUM. FASCIA
2.3 2.72.5 3 4
C
D.5
HAC
A.4
C.6
9' - 0"
ACT
2x2
12' - 0"
GWB
REFLECTED CEILING PLAN LEGEND
DENOTES GWB
SOFFIT/CEILING
CEILING HEIGHT
DESIGNATION (WHEN
HEIGHT VARIES FROM
TYPICAL)
FLUORESCENT
LIGHT FIXTURE
2'x4' SURFACE MOUNT
LED FIXTURE
EQ. A EQ. A
E Q
B
E Q
B
EXIT SIGN (SHADED
AREA INDICATES
DIRECTION OF EGRESS)
SUPPLY DIFFUSER
RETURN GRILL
PENDANT
MOUNTED LIGHT
DOWN LIGHT
FIXTURE
CEILING CONTRACTOR TO MEASURE EACH CEILING AREA AND
ESTABLISH A CEILING LAYOUT TO BALANCE BORDER WIDTHS AT
OPPOSITE EDGES OF EACH ROOM. AVOID USE OF LESS-THAN 6"
TILES.
A.F.F.10' 6"
PERIMETER
RECESSED WALL
SLOT LIGHT FIXTURE
FIRE ALARM STROBE
FAA
FIRE ALARM
ANNUCIATOR
F
FIRE ALARM PULL
STATION
FIRE ALARM
STROBE LIGHT
S
H
HEAT DETECTOR
SMOKE DETECTOR
FIRE ALARM / HORN /
STROBE LIGHT - WALL
MOUNTED
FIRE ALARM / HORN /
STROBE LIGHT - CEILING
MOUNTED
SPRINKLER HEAD
SPRINKLER HEAD
2'x4' LAY-IN LED
RETURN GRILL
EXHAUST GRILL
DENOTES METAL PANEL
CEILING
CEILING HATCH
CONCRETE CAP
(VAULT IN HONOR GUARD BLDG)
# KEY NOTES:
Dwg of
SHEET NOTES:
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T O
N
C E
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 001
A-110
FIRST FLOOR REFLECTED CEILING
PLAN - ADMINISTRATION BLDG.
ACLCW 40 186JULY 28, 2023
X
BID DOCUMENTS
22-023
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRS
Scale: 1/4" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
N O
R T
H0 4 8 16
A. ALL CEILING AT 8'-0" AFF, UNO.
B. ALL SOFFITS AND BULKHEADS AT 7'-6" AFF, UNO.
C. CENTER DEVICES, DOWNLIGHTS, SPRINKLER
HEADS, HVAC GRILLS, ETC. IN CEILING TILES, UNO.
D. CENTER EXIT SIGNS OVER DOORS, UNO.
E. ALIGN FACE OF SOFFIT/BULKHEAD WITH FACE OF
PARTITION, UNO.
F. THE CONTRACTOR SHALL VERIFY THAT ACCESS
PANELS OF APPROPRIATE SIZE AND TYPE ARE
INSTALLED IN NON-ACESSIBLE TYPE CEILINGS
WHERE ACCESS, SERVICE, OR ADJUSTMENT TO
MECHANICAL, PLUMBING, OR ELECTRICAL ITEMS
MAY BE REQUIRED.
G. ACCESS PANELS ARE NOT PERMITTED IN SOFFITS
UNLESS SHOWN ON DRAWINGS. CHECK ALL
VALVES, FIRE DAMPERS, REHEAT BOXES, ETC. FOR
ACCESS POINTS. ARRANGE FIRE AND SMOKE
DAMPER ACCESS FROM NON-CORRIDOR SIDE.
H. PAINT CUT EDGES OF ACT TO MATCH CEILING TILE
WHERE EXPOSED TO VIEW.
I. CONTRACTOR TO REVIEW CEILING LAYOUT AS
SHOWN AND NOTIFY ARCHITECT OF ANY CONFLICTS
BEFORE PROCEEDING WITH CONSTRUCTION.
J. WHERE EXISTING SPACES ARE SCHEDULED TO
RECEIVE NEW PAINT, CONTRACTOR SHALL PATCH
AND REPAIR WALLS TO LEVEL 4 FINISH PRIOR TO
PAINTING.
K. WHERE EXISTING WALLS TO REMAIN HAVE UNEVEN
SURFACE DUE TO DEMOLITION OR OTHER
CONDITIONS, INSTALL 1/4" GYP BD OVER EXISTING
WALL AND FINISH TO LEVEL 4 FINISH.
1 PROVIDE 4" C-STUD FRAMING AT 16" O.C. AT
BOTTOM CHORD OF TRUSSES AND ONE LAYER
5/8" GWB TAPERED & PAINTED.
R
DRAWING ADDENDUM 09/13/2023(SHEET REISSUED)
24514
LICENSED
ARCHITECT
DocuSign Envelope ID: D0796BBE-4211-42B5-8633-76AF6E2E1EB6
9/14/2023
A B C D
K L
SHOP
PARTS
/TOOLS
MUD
ROOM
ENCLOSED
MAINTENANCE
BAYS
MECHANICAL
ROOM
WOMEN'S
LOCKER ROOM
& TOILET
MEN'S LOCKER
ROOM
TOILET/
SHOWER
LUNCH ROOM
VEST.
EXPOSED CEILING
EXPOSED CEILING
9' - 0"
ACT
2x2
9' - 0"
GWB
MAINT.
BAY
ALUM. SOFFIT
9' - 0"
GWB
S L O
P E
EXISTING SLOPED
GWB CEILING
EXISTING SLOPED GWB SILL
@ CLERESTORY WINDOW
EXISTING CLERESTORY WINDOW
EXISTING SLOPED GWB CEILING
& LIGHT FIXTURES TO REMAIN.
GC TO VIF FIXTURES, SEE ALSO.
ELEC. DWGS.; RELOCATE AS
NECESSARY.
S L O
P E
EXISTING GWB
BULKHEAD TO REMAIN
S L O
P E
5.1
5.2
6.1
6.2
7.1
EXIST. CEILING AND LIGHT
FIXTURES TO REMAIN
CL
E Q
E Q
A-312
A-312
A-312
9' - 0"
GWB
9' - 6"
GWB
9' - 6"
GWB
NEW ACT
EXISTING FAN TO
REMAIN
REFLECTED CEILING PLAN LEGEND
DENOTES GWB
SOFFIT/CEILING
CEILING HEIGHT
DESIGNATION (WHEN
HEIGHT VARIES FROM
TYPICAL)
FLUORESCENT
LIGHT FIXTURE
2'x4' SURFACE MOUNT
LED FIXTURE
EQ. A EQ. A
E Q
B
E Q
B
EXIT SIGN (SHADED
AREA INDICATES
DIRECTION OF EGRESS)
SUPPLY DIFFUSER
RETURN GRILL
PENDANT
MOUNTED LIGHT
DOWN LIGHT
FIXTURE
CEILING CONTRACTOR TO MEASURE EACH CEILING AREA AND
ESTABLISH A CEILING LAYOUT TO BALANCE BORDER WIDTHS AT
OPPOSITE EDGES OF EACH ROOM. AVOID USE OF LESS-THAN 6"
TILES.
A.F.F.10' 6"
PERIMETER
RECESSED WALL
SLOT LIGHT FIXTURE
FIRE ALARM STROBE
FAA
FIRE ALARM
ANNUCIATOR
F
FIRE ALARM PULL
STATION
FIRE ALARM
STROBE LIGHT
S
H
HEAT DETECTOR
SMOKE DETECTOR
FIRE ALARM / HORN /
STROBE LIGHT - WALL
MOUNTED
FIRE ALARM / HORN /
STROBE LIGHT - CEILING
MOUNTED
SPRINKLER HEAD
SPRINKLER HEAD
2'x4' LAY-IN LED
RETURN GRILL
EXHAUST GRILL
DENOTES METAL PANEL
CEILING
CEILING HATCH
CONCRETE CAP
(VAULT IN HONOR GUARD BLDG)
NOT IN PROJECT SCOPE
Dwg of
SHEET NOTES:
WALL RATING LEGEND
1 HR - FIRE SEPARATION
2 HR - FIRE SEPARATION
SMOKE RESISTIVE HAZARDOUS AREAS S S S
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 001
A-111
FIRST FLOOR REFLECTED CEILING
PLAN - EXIST. ADMINISTRATION BLDG.
ACLCW 41 186JULY 28, 2023
X
BID DOCUMENTS
22-023
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRS
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
Scale: 1/4" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
NORTH
0 4 8 16
A. ALL CEILING AT 8'-0" AFF, UNO.
B. ALL SOFFITS AND BULKHEADS AT 7'-6" AFF, UNO.
C. CENTER DEVICES, DOWNLIGHTS, SPRINKLER
HEADS, HVAC GRILLS, ETC. IN CEILING TILES, UNO.
D. CENTER EXIT SIGNS OVER DOORS, UNO.
E. ALIGN FACE OF SOFFIT/BULKHEAD WITH FACE OF
PARTITION, UNO.
F. THE CONTRACTOR SHALL VERIFY THAT ACCESS
PANELS OF APPROPRIATE SIZE AND TYPE ARE
INSTALLED IN NON-ACESSIBLE TYPE CEILINGS
WHERE ACCESS, SERVICE, OR ADJUSTMENT TO
MECHANICAL, PLUMBING, OR ELECTRICAL ITEMS
MAY BE REQUIRED.
G. ACCESS PANELS ARE NOT PERMITTED IN SOFFITS
UNLESS SHOWN ON DRAWINGS. CHECK ALL
VALVES, FIRE DAMPERS, REHEAT BOXES, ETC. FOR
ACCESS POINTS. ARRANGE FIRE AND SMOKE
DAMPER ACCESS FROM NON-CORRIDOR SIDE.
H. PAINT CUT EDGES OF ACT TO MATCH CEILING TILE
WHERE EXPOSED TO VIEW.
I. CONTRACTOR TO REVIEW CEILING LAYOUT AS
SHOWN AND NOTIFY ARCHITECT OF ANY CONFLICTS
BEFORE PROCEEDING WITH CONSTRUCTION.
J. WHERE EXISTING SPACES ARE SCHEDULED TO
RECEIVE NEW PAINT, CONTRACTOR SHALL PATCH
AND REPAIR WALLS TO LEVEL 4 FINISH PRIOR TO
PAINTING.
K. WHERE EXISTING WALLS TO REMAIN HAVE UNEVEN
SURFACE DUE TO DEMOLITION OR OTHER
CONDITIONS, INSTALL 1/4" GYP BD OVER EXISTING
WALL AND FINISH TO LEVEL 4 FINISH.
R
DRAWING ADDENDUM 09/13/2023(SHEET REISSUED)
24514
LICENSED
ARCHITECT
EQ EQ
Q
E Q
EXPOSED CEILING
H06
LOCKER ROOM
H05
ADA CHANGE
ROOM
H11
TOILET
H01
LOUNGE
H03
VAULT
MECH /
ELEC
H07
H10
WORK
LEADER'S
OFFICE
H12
FOREMAN'S
OFFICE
H04
TOILET
H08
HR LINKS
H09
CORRIDOR
EQ EQ
HA
HB
HC
HD
H2H1
HE
HF
H08A
TELECOM.
CLOSET
A-302
ALUM. PANEL SOFFIT
REFLECTED CEILING PLAN LEGEND
DENOTES GWB
SOFFIT/CEILING
CEILING HEIGHT
DESIGNATION (WHEN
HEIGHT VARIES FROM
TYPICAL)
FLUORESCENT
LIGHT FIXTURE
2'x4' SURFACE MOUNT
LED FIXTURE
EQ. A EQ. A
E Q
B
E Q
B
EXIT SIGN (SHADED
AREA INDICATES
DIRECTION OF EGRESS)
SUPPLY DIFFUSER
RETURN GRILL
PENDANT
MOUNTED LIGHT
DOWN LIGHT
FIXTURE
CEILING CONTRACTOR TO MEASURE EACH CEILING AREA AND
ESTABLISH A CEILING LAYOUT TO BALANCE BORDER WIDTHS AT
OPPOSITE EDGES OF EACH ROOM. AVOID USE OF LESS-THAN 6"
TILES.
A.F.F.10' 6"
PERIMETER
RECESSED WALL
SLOT LIGHT FIXTURE
FIRE ALARM STROBE
FAA
FIRE ALARM
ANNUCIATOR
F
FIRE ALARM PULL
STATION
FIRE ALARM
STROBE LIGHT
S
H
HEAT DETECTOR
SMOKE DETECTOR
FIRE ALARM / HORN /
STROBE LIGHT - WALL
MOUNTED
FIRE ALARM / HORN /
STROBE LIGHT - CEILING
MOUNTED
SPRINKLER HEAD
SPRINKLER HEAD
2'x4' LAY-IN LED
RETURN GRILL
EXHAUST GRILL
DENOTES METAL PANEL
CEILING
CEILING HATCH
CONCRETE CAP
(VAULT IN HONOR GUARD BLDG)
Dwg of
SHEET NOTES:
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 001
A-112
FIRST FLOOR REFLECTED CEILING
PLAN - HONOR GUARD BLDG.
ACLCW 42 186JULY 28, 2023
X
BID DOCUMENTS
22-023
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRS
Scale: 1/4" = 1'-0"
FIRST FLOOR REFLECTED CEILING PLAN
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
NORTH
0 4 8 16
A. ALL CEILING AT 8'-0" AFF, UNO.
B. ALL SOFFITS AND BULKHEADS AT 7'-6" AFF, UNO.
C. CENTER DEVICES, DOWNLIGHTS, SPRINKLER
HEADS, HVAC GRILLS, ETC. IN CEILING TILES, UNO.
D. CENTER EXIT SIGNS OVER DOORS, UNO.
E. ALIGN FACE OF SOFFIT/BULKHEAD WITH FACE OF
PARTITION, UNO.
F. THE CONTRACTOR SHALL VERIFY THAT ACCESS
PANELS OF APPROPRIATE SIZE AND TYPE ARE
INSTALLED IN NON-ACESSIBLE TYPE CEILINGS
WHERE ACCESS, SERVICE, OR ADJUSTMENT TO
MECHANICAL, PLUMBING, OR ELECTRICAL ITEMS
MAY BE REQUIRED.
G. ACCESS PANELS ARE NOT PERMITTED IN SOFFITS
UNLESS SHOWN ON DRAWINGS. CHECK ALL
VALVES, FIRE DAMPERS, REHEAT BOXES, ETC. FOR
ACCESS POINTS. ARRANGE FIRE AND SMOKE
DAMPER ACCESS FROM NON-CORRIDOR SIDE.
H. PAINT CUT EDGES OF ACT TO MATCH CEILING TILE
WHERE EXPOSED TO VIEW.
I. CONTRACTOR TO REVIEW CEILING LAYOUT AS
SHOWN AND NOTIFY ARCHITECT OF ANY CONFLICTS
BEFORE PROCEEDING WITH CONSTRUCTION.
J. WHERE EXISTING SPACES ARE SCHEDULED TO
RECEIVE NEW PAINT, CONTRACTOR SHALL PATCH
AND REPAIR WALLS TO LEVEL 4 FINISH PRIOR TO
PAINTING.
K. WHERE EXISTING WALLS TO REMAIN HAVE UNEVEN
SURFACE DUE TO DEMOLITION OR OTHER
CONDITIONS, INSTALL 1/4" GYP BD OVER EXISTING
WALL AND FINISH TO LEVEL 4 FINISH.
R
DRAWING ADDENDUM 09/13/2023(SHEET REISSUED)
24514
LICENSED
ARCHITECT
1.12.12.9
STANDING SEAM METAL
ROOFING
CONT. ALUMINUM
GUTTER
ALUM. FASCIA
METAL PANEL SIDING
WITH 4" BANDS
FACE BRICK VENEER
CAST STONE
36" Ø VENT
LOUVER
ALUM. FASCIA
METAL PANEL SIDING WITH
4" BANDS
FACE BRICK VENEER
CAST STONE
ALUMINUM WINDOW
STANDING SEAM
METAL ROOFING
CONT. ALUMINUM
GUTTER
TPO ROOFING &
COPING
W4
W3 W3 W3
W2GRAVE LOCATOR
ALUM. DOWNSPOUT
RIDGE CAP
W3
2.32.7 2.534
L-4
5"
12"
A-301
A-310
CONTROL JOINT (C.J.) C.J.
1.1 2.1 2.9
STANDING SEAM METAL
ROOFING W/ RIDGE CAP
CONT. ALUMINUM
GUTTER
ALUM. FASCIA
METAL PANEL SIDING
WITH 4" BANDS
FACE BRICK VENEER
CAST STONE
STANDING SEAM
METAL ROOFING
CONT. ALUMINUM
GUTTER
ALUM., FASCIA
METAL PANEL SIDING
WITH 4" BANDS
FACE BRICK VENEER
CAST STONE
36" Ø VENT LOUVER
ALUMINUM WINDOW
TPO ROOFING &
COPING & ALUM.
FASCIA
W2 W2 W2 W2
W4
CAST STONE
ALUMINUM WINDOW
GRAVE LOCATOR
ALUM. DOWNSPOUT
2.3 2.72.5 3 4
6"
12"
A-301 _____ 2
A-312
A.1 A.8 C.9
STANDING SEAM
METAL ROOFING W/
RIDGE CAP
CONT. ALUMINUM
GUTTER
ALUM. FASCIA
METAL PANEL SIDING
WITH 4" BANDS
FACE BRICK VENEER
CAST STONE
36" Ø VENT LOUVER
BARGE BD.
W2 ALUM. DOWNSPOUT
A.0 C D.5
L-1
A.4 C.6
A-301
FIRST FLOOR
0"
ROOF LEVEL
12' - 0"
A.8 C.9
ROOF DRAIN AND
OVERFLOW
COMBINATION
ALUM. PANEL SOFFIT
ALUM. FASCIA
TPO ROOFING
FLASHING
1/4" / 12" 1/4" / 12"
8" C-JOIST @ 48" O.C.
"1
/4
"7
/4
9' - 6"
1.5" METAL DECKING
CA.4 C.6
123 121 122
A-301 _____2
A-310
L-4
A.1A.8C.9
STANDING SEAM
METAL ROOFING
CONT. ALUMINUM GUTTER
AND DOWNSPOUT
ALUM. FASCIA
METAL PANEL SIDING
WITH 4" BANDS
FACE BRICK VENEER
CAST STONE
30" Ø VENT LOUVER
BARGE BD.
TPO ROOFING AND
FLASHING @ CONNECTOR
CONT. ALUMINUM
GUTTER O/ FASCIA BD.
GRAVE LOCATOR
W3 W3 W3
RIDGE CAP
A.0CD.5
6"
12"
A.4C.6
A-301
A-310
A-310
FIRST FLOOR
0"
ROOF LEVEL
12' - 0"
A.8
CONT. ALUMINUM
GUTTER &
DOWNSPOUT
ALUM. FASCIA
METAL PANEL SIDING
WITH 4" BANDS
FACE BRICK VENEER
CAST STONE
STANDING SEAM METAL ROOFING
TPO ROOF & COPING
C
6"
12"
C.6
A-301 _____ 2
A-310
Dwg of
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 001
A-201
EXTERIOR ELEVATIONS -
ADMINISTRATION BLDG.
ACLCW 43 186JULY 28, 2023
X
BID DOCUMENTS
22-023
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRS
Scale: 1/4" = 1'-0"
EAST ELEVATION - ADMIN. BLDG.
Scale: 1/4" = 1'-0"
WEST ELEVATION - ADMIN. BLDG.
Scale: 1/4" = 1'-0"
NORTH ELEVATION - ADMIN. BLDG.
Scale: 1/4" = 1'-0"
RESTROOMS NORTH ELEVATION
Scale: 1/4" = 1'-0"
SOUTH ELEVATION - ADMIN. BLDG.
Scale: 1/4" = 1'-0"
RESTROOM SOUTH ELEVATION
R
DRAWING ADDENDUM 09/13/2023
24514
LICENSED
ARCHITECT
1. REFERENCE ROOM FINISH SCHEDULE , FINISH MATERIAL LEGEND AND SPECIFICATION 09 06 00 SCHEDULE OF
FINISHES FOR MORE INFORMATION.
2. REFERENCE REFLECTED CEILING PLAN FOR ADDITIONAL CEILING INFO.
3. PREPARE ALL FLOOR AND WALL CONSTRUCTION, NEW AND/OR EXISTING, TO RECEIVE NEW FINISHES IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR ALL
FINISHES.
4. PRIOR TO INSTALLATION OF NEW FINISHES, CONTRACTOR SHALL INSPECT ALL SUBSTRATES. IF A SUBSTRATE IS DEEMED UNACCEPTABLE, THE CONTRACTOR SHALL TAKE THE NECESSARY STEPS TO RECTIFY THE SITUATION OR CONTACT THE COR WITH THE CONCERN. PROCEEDING WITH THE INSTALLATION OF FINISHES
WILL BE INDICATION THAT THE INSTALLER / FINISHER ACCEPTS CONDITION OF SUBSTRATE.
5. USE MANUFACTURER'S RECOMMENDED INSTALLATION METHODS AND MATERIALS FOR ALL FINISHES.
6. ALL NECESSARY TILE FLOORING UNDERLAYMENT TO BE PROVIDED AND INSTALLED BY FLOORING CONTRACTOR. ALL SETTING AND UNDERLAYMENT SYSTEMS TO BE FROM SAME MANUFACTURER AND
APPROVED BY FLOORING MANUFACTURER.
7. ALL FLOORING TRANSITIONS SHALL COMPLY WITH ADA GUIDELINES. FLOORING CONTRACTOR TO SUBMIT A DIAGRAM SHOWING FLOORING TRANSITION LOCATIONS FOR DESIGNERS APPROVAL PRIOR TO INSTALLATION.
8. ALL FLOOR TRANSITIONS BETWEEN DISALIKE MATERIALS SHALL BE ANODIZED ALUMINUM METAL TRIM AND TO
BE LOCATED AT CENTERLINE OF DOOR WHEN IN CLOSED POSITION
9. ALL OUTSIDE AND INSIDE CORNERS OF WALL TILE SHALL BE ANODIZED ALUMINUM METAL TRIM.
10. ALL TRANSITIONS BETWEEN WALL AND FLOOR TILE SHALL BE ANODIZED COVE ALUMINUM METAL TRIM
STRAIGHT, INSIDE AND OUTSIDE CORNERS.
11. ALIGN FLOORING TRANSITIONS WITH FINISH BASE EXCEPT AT DOORS, UNLESS NOTED OTHERWISE.
12. FLOOR FINISHES ARE TO EXTEND UNDER NEW BUILT-IN CABINETS.
13. FINISH LEVEL OF GYP. BD. WALLS AND SOFFITS TO BE LEVEL 4, UNLESS NOTED OTHERWISE.
14. ALL PAINTED WALLS TO BE PAINTED P-1, UNLESS NOTED OTHERWISE.
15. ALL GYP. BOARD CEILINGS TO BE PAINTED P-1, UNLESS NOTED OTHERWISE.
16. ALL PAINTED SURFACES SHALL RECEIVE A MINIMUM OF (1) ONE BASE COAT AND (2) TWO FINISH COATS.
17. PAINTED SHEEN LEVEL TO BE SATIN/EGG-SHELL FOR ALL WALLS, U.N.O. SHEEN FOR ALL WET AREA WALLS, METAL DOORS AND METAL FRAMES TO BE SEMI-GLOSS.
18. PAINT ALL EXISTING AND NEW HOLLOW METAL DOORS AND WINDOWS FRAMES IN SCOPE OF WORK P-5.
19. PAINT ALL EXPOSED METAL SURFACES, SUCH AS GRILLES, ACCESS PANELS, AND FIRE EXTINGUISHER
CABINETS, ETC. WITH PAINT TO MATCH ADJACENT SURFACE.
20. ALL HOLLOW METAL DOORS AND FRAMES TO BE PAINTED P-5.
21. REFER TO SHEET I-501 FOR INTERIOR DETAILS FOR FLOOR TRANSITIONS AND OTHER DETAILS.
22. CAULK AROUND ALL NEW WINDOW SILLS, DOORS, WINDOWS.AND NEW FINISHES AROUND ELEVATORS.
23. PAINT ALL SIDES OF GYPSUM BOARD BULKEHAD SAME COLOR. PAINT P-1 UNLESS NOTED OTHERWISE.
EXTEND THE SDT-1 IN THE TELECOM ROOMS UNDER DOOR TO THE CORRIDOR WITH A METAL TRANSITION
BETWEEN NEW AND EXISTING. PROVIDE METAL FLOOR TRANSITION BETWEEN ALL TELECOM ROOM FLOORING
AND ADJACENT FLOORING.
24. THE CONTRACTOR SHALL INSTALL WINDOW FILM ON ANY EXPOSED OR ENCLOSED WINDOWS WITHIN THE
TELECOM SCOPE OF WORK.
25. PLYWOOD BACKER BOARD IN TELECOM ROOMS SHALL BE PAINTED WITH (2 COATS) OF FIRE RETARDANT
PAINT AND SHALL MATCH P-1 COLOR. LEAVE ONE STAMP ON PLYWOOD EXPOSED.
1. ALL CORNER GUARDS TO BE FROM TOP OF BASE TO CEILING (EDIT PER HEIGHT PER PROJECT).
2. PROVIDE BLOCKING IN WALLS FOR ALL CHAIR RAILS, CRASH RAILS, HAND RAILS AND BUMPER RAILS.
3. TYPICAL HIGH IMPACT WALLCOVERING HEIGHT IS 4'-0"H IN ROOMS AND CORRIDORS ARE 3’-0”H, U.N.O.
4. SEE TYPICAL DETAIL SECTIONS ON SHEET I-501.
4. HOLD BACK HANDRAIL AND BUMPER RAIL 2" FROM CORNER GUARDS AND DOOR FRAMES.
5. HANDRAIL NOT TO BE BEHIND DOORS WITH CLOSERS AND START HANDRAIL 6" AWAY FROM START OF
DOOR WHEN OPEN.
6. STANDARD HIGH IMPACT WALLCOVERING (SHEET) TO BE .040” THICKNESS FOR DRYWALL APPLICATIONS
AND .060” THICKNESS FOR BRICK/CMU.
7. SEE SPECIFICATION 09 06 00 SCHEDULE OF FINISHES FOR MATERIALS AND FINISHES.
ABBREVIATION LEGEND
CG: CORNER GUARD
HR: HANDRAIL
HIW: HIGH IMPACT WALLCOVERING
BR: BUMPER RAIL
CHR: CHAIR RAIL
1. REFER TO G002 FOR STANDARD MOUNTING HEIGHTS AND BLOCKING. REFER TO EQUIPMENT DRAWINGS FOR LOCATIONS AND ADDITIONAL DIMENSIONS. PROVIDE BLOCKING FOR ALL WALL MOUNTED EQUIPMENT, CASEWORK, MILLWORK AND WALL PROTECTION AS REQUIREMENT BY MANUFACTURER'S REQUIREMENTS FOR INSTALLATION.
2. REFER TO MECHANICAL, ELECTRICAL, PLUMBING, TEL-COM AND LOW VOLTAGE DRAWINGS FOR ADDITIONAL
REQUIRED UTILITY CONNECTIONS AND LOCATIONS.
3. FURNITURE, FIXTURES AND EQUIPMENT SHOWN ON PLANS AND SCHEDULES ARE FOR
COORDINATION AND SPACIAL PURPOSES ONLY, NOT TO BE USED FOR ACTIVATION PURCHASING
4. REFER TO SHEETS I-431 THRU 434 FOR ENLARGED TOILET ROOMS.
5. REFER TO REFLECTED CEILING PLANS FOR CEILING MOUNTED EQUIPMENT LOCATIONS .
6. SEE ENLARGED EQUIPMENT PLANS ON SHEETS I-421 THRU 422
7. SEE EQUIPMENT SCHEDULES ON SHEETS I-601 FOR SPECIFICS ON EQUIPMENT BY ROOM.
8. ITEM TAGS INCLUDE ACQUISITION AND INSTALLATION RESPONSIBILITIES (ACQ.), DENOTED AS FOLLOWS:
EQUIPMENT SCHEDULE LEGEND
1. "VV" = VA FURNISHED & VA INSTALLED
2. "VC" = VA FURNISHED & CONTRACTOR INSTALLED
3. “CC" = CONTRACTOR FURNISHED & CONTRACTOR INSTALLED
PLASTIC LAMINATE CASEWORK GENERAL NOTES
THE FOLLOWING NOTES ARE SPECIFIC TO CASEWORK AND ARE IN ADDITION TO THE GENERAL FINISH NOTES.
1. FIELD VERIFY ALL CASEWORK AND SHELVING DIMENSIONS.
1. PROVIDE WALL BRACKET SUPPORTS AT 36" O.C. MAX. TO SUPPORT COUNTERTOP CONTINUING AT KNEE SPACE.
2. USE 2-1/2" DIAMETER GROMMETS WHERE GROMMETS ARE INDICATED AT 3’-0” O.C. AT ALL KNEE SPACES.
3. PROVIDE FINISHED END PANEL AT EXPOSED CASEWORK ENDS AND BACKS AS NEEDED. PANEL TO MATCH PLASTIC LAMINATE, STAINLESS STEEL OR MELAMINE FINISH, BASED ON CABINET TYPE. WHEN FILLER PANELS ARE REQUIRED AT BOTH ENDS OF CASEWORK TERMINATION, BOTH FILLER PANELS SHALL BE EQUAL WIDTH, UNLESS OTHERWISE NOTED.
4. ADD FILLER PANEL AS NEEDED AT CABINETS, WARDROBES, DRAWERS, APPLIANCES, ETC. TO ENSURE FULL DOOR SWING AND DRAWER OPERATION. PROVIDE FILLER PANELS AND TRIM WHERE EQUIPMENT IS LOCATED
WITHIN CABINETS.
5. ALL COUNTERTOPS TO BE SOLID SURFACE WITH POST FORM PROFILE WITH 1/2" RADIUS AT EXPOSED CORNERS.
ALL COUNTERTOPS ARE 1 1/2" THICK WITH 4" HIGH BACK/SIDE SPLASHES UNLESS NOTED OTHERWISE. ALL JOINTS IN COUNTERTOPS, SPLASHES AND CURBS SHALL ALIGN AND BE SMOOTH. PROVIDE END SPLASH AT SIDES WHEN COUNTERTOP IS ADJACENT TO WALL. COUNTERTOPS AND SIDE/BACKSPLASHES TO BE INTEGRAL.
ALL EDGES TO BE EASED THAT ARE EXPOSED.
6. ALL COUNTERTOPS TO EXTEND 1" BEYOND FRONT OF CABINET DOOR FACE.
7. ALL WALL CABINETS TO BE 15"D OUT TO OUT UNLESS NOTED OTHERWISE. PROVIDE LIGHT VALANCES WHERE
UNDERCABINET LIGHTS ARE PROVIDED.
8. ALL WALL CABINETS TO HAVE SLOPE TOPS UNLESS A BULKHEAD IS PRESENT.
9. ALL SHELVING SHOWN WITH DASHED LINES IN ELEVATIONS TO BE ADJUSTABLE.
10. ALL BASE CABINETS TO BE 23" DEEP WITH 24” DEEP COUNTERTOP INCLUDING BACKSPLASH UNLESS NOTED
OTHERWISE.
11. PROVIDE AN APRON AT ALL KNEE SPACES & SINKS, U.N.O. PROVIDE 30" WIDE (MIN. x 27" HIGH (MIN.) CLEAR OPEN
SPACE UNDER EACH ADA ACCESSIBLE SINK.
12. PROVIDE SHEET METAL BLOCKING IN WALL CAVITIES FOR ITEMS THAT ARE REQUIRED TO BE SECURED TO THE WALLS. REFERENCE MECHANICAL, PLUMBING, ELECTRICAL AND TECHNOLOGY DRAWINGS. COORDINATE WITH
FURNITURE SUPPLIER WHERE APPROPRIATE.
13. SEE SHEET I-202 FOR TYPICAL CABINET SECTIONS.
1. CONTRACTOR TO COORDINATE THE TEXT OF SIGN INSERTS WITH COR. COR TO GIVE
FINAL APPROVAL OF ALL SIGNAGE TEXT, DESIGN AND LOCATIONS. ALL SIGNAGE TO MEET VA NCA SIGNAGE
GUIDELINES TO MEET INSTALLATION HEIGHTS.
2. SIGNS TO MATCH VAMC DAYTON CEMETARY CAMPUS SIGNAGE STANDARDS. COLORS TO BE DETERMINED BY
FACILITIES.
3. ALL SIGNAGE SHALL BE CONTRACTOR FURNISHED AND INSTALLED U.N.O.
4. PERMANENT ROOM SIGNAGE MUST INCLUDE RAISED LETTERS AND BRAILLE AND MEET ADA GUIDELINES.
5. IF WALL SPACE IS NOT AVAILABLE FOR SIGNAGE ON LATCH SIDE OF DOOR PER MOUNTING STANDARDS, SIGNS
SHALL BE INSTALLED PER CURRENT ADA STANDARDS ON NEAREST ADJACENT WALL.
6. ALL EXISTING SIGNAGE IN DEMOLISHED AREAS TO BE TURNED INTO CEMETARY DIRECTOR. NO SIGNAGE TO BE
DISCARDED BY CONTRACTOR.
MOUNTING LEGEND
WM = WALL MOUNTED
DM = DOOR MOUNTED
FM = FLAG MOUNTED
BM = BULKHEAD MOUNTED
CM= CEILING MOUNTED
Dwg of
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 001
I-001R
GENERAL NOTES, ABBREVIATIONS
AND ROOM FINISH SCHEDULE
KLCEMD 57 186JULY 28, 2023
X
BID DOCUMENTS
22-023
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRS
FINISH ABBREVIATIONS
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT
AFF ABOVE FINISHED FLOOR
AL ALUMINUM
AP ACOUSTIC WALL PANEL
BR BUMPER RAIL
CC CUBICLE CURTAIN
CR CRASH RAIL
CHR CHAIR RAIL
CG CORNER GUARD
CJ CONTROL JOINT
CMU CONCRETE MASONRY UNIT
CON CONCRETE FLOORING
CR CARD READER
CPT CARPET
DG DOOR FRAME GUARD
EG END WALL GUARD
EF EPOXY FLOORING
EP EPOXY PAINT
EX EXISTING
EXJ EXPANSION JOINT
EXP EXPOSED
FRP FIBERGLASS REINFORCED PANELS
G GROUT
GYP GYPSUM WALL BOARD
HR HAND RAIL
HIW HIGH IMPACT WALLCOVERING
LF LINEAR FEET (FOOT)
LVT LUXURY VINYL TILE
MTL METAL
MISC MISCELLANEOUS
NA NOT APPLICABLE
P PAINT
PFIN PREFINISHED
PL PLASTIC LAMINATE
PT PORCELAIN TILE
PTB PORCELAIN TILE BASE
RB RUBBER BASE
RES RESINOUS FLOORING
RESB RESINOUS FLOORING BASE
RP RESIN PANEL SYSTEM
SC SEALED CONCRETE
SDT STATIC DISSAPATIVE TILE
SF SQUARE FEET (FOOT)
SHC SHOWER CURTAIN
SS SOLID SURFACE
SST STAINLESS STEEL
TP TOILET PARTITION
TYP TYPICAL
UFIN UNFINISHED
UNO UNLESS NOTED OTHERWISE
VIF VERIFY IN FIELD
WSF WELDED SHEET FLOORING
WSFB WELDED SHEET FLOORING BASE
WF WINDOW FILM
WP WALL PROTECTION
WS WINDOW SHADE
ROOM FINISH SCHEDULE
ROOM NO. NAME FLOOR BASE
WALLS CEILING
REMARKSEAST NORTH SOUTH WEST FINISH
ADMINISTRATION BUILDING
100 LOBBY WOC-1 RB-1 P-1 - P-1 P-1 ACT-1
101 RECEPTION LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
101A GRAVE
LOCATOR RM.
LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
102 CORRIDOR LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
103 OFFICE CPT-1 RB-1 P-1 P-2 P-1 P-1 ACT-1
104 OFFICE CPT-1 RB-1 P-1 P-3 P-1 P-1 ACT-1
105 DIRECTOR'S
OFFICE
CPT-1 RB-1 P-1 P-4 P-1 P-1 ACT-1
106 STORAGE LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
107 MECH./ ELEC. SEALED
CONCRETE
RB-1 P-1 P-1 P-1 P-1 EXPOSED
STRUCTURE
108 STAFF TOILET PT-1 TRIM PT-2 PT-2 PT-2 PT-2 ACT-1
109 HAC WSF-1 WSFB-1 HIW-1/EP-1 HIW-1/EP-1 HIW-1/EP-1 HIW-1/EP-1 ACT-1 HIW-1 @ 3'-8"H
110 STAFF TOILET PT-1 TRIM PT-2 PT-2 PT-2 PT-2 ACT-1
111 CORRIDOR LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
112 LUNCH ROOM LVT-1 RB-1 P-1 P-1 P-2 P-1 ACT-1
113 RECORDS
STORAGE
LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
114 STORAGE LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
115 CORRIDOR LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
116 WORK
STATIONS
LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
117 CORRIDOR LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
118 OPERATIONS WSF-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
119 TR SDT-1 RB-1 P-6 P-6 P-6 P-6 EXPOSED
STRUCTURE
120 CONFERENCE
ROOM
LVT-1 RB-1 P-1 P-1 P-1 P-4 ACT-1
121 HAC WSF-1 WSFB-1 HIW-1/EP-1 HIW-1/EP-1 HIW-1/EP-1 HIW-1/EP-1 GYP-1 HIW-1 @ 3'-8"H
122 WOMEN'S PT-1 PTB-1 PT-2 PT-2 PT-2 PT-2 GYP-1
123 MEN'S PT-1 PTB-1 PT-2 PT-2 PT-2 PT-2 GYP-1
EXISTING ADMIN BUILDING
108 CORRIDOR LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
109 WOMEN'S
LOCKER ROOM
& TOILET
PT-1 PTB-1 PT-2 PT-2 PT-2 PT-2 GYP-1
110 LUNCH ROOM LVT-1 RB-1 P-1 P-1 P-1 P-1 EXPOSED SLOPED
GWB CEILING
111 MUD ROOM RES-1 RESB-1 FRP-1 FRP-1 FRP-1 FRP-1 ACT-1/GYP-1 FRP-1, FULL HEIGHT ALL WALLS IN MUD
ROOM
112 PARTS /TOOLS SEALED
CONCRETE
RB-1 P-1 P-1 P-1 P-1 EXPOSED CEILING,
EXISTING GWB
BULKHEAD TO
REMAIN
124 TOILET/
SHOWER
RES-1 RESB-1 EP-1 EP-1 EP-1 EP-1 GYP-1
125 MEN'S LOCKER
ROOM
WSF-1 WSFB-1 P-1 P-1 P-1 P-1 GYP-1
126 VEST. WOC-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
1302B EQUIP. STO. 1 WSF-1 WSFB-1 P-1 P-1 P-1 P-1 ACT-1
1302C EQUIP. STO. 2 WSF-1 WSFB-1 P-1 P-1 P-1 P-1 ACT-1
HONOR GUARD BUILDING
H01 LOUNGE LVT-1 RB-1 P-1 P-4 P-1 P-1 GYP-1
H02 CORRIDOR LVT-1 RB-1 P-1 P-1 P-1 P-1 GYP-1
H03 VAULT LVT-1 RB-1 P-1 P-1 P-1 P-1 GYP-1
H04 TOILET PT-1 RB-1 PT-2 PT-2 PT-2 PT-2 GYP-1
H05 ADA CHANGE
ROOM
WSF-1 WSFB-1 P-1 P-1 P-1 P-1 GYP-1
H06 LOCKER ROOM WSF-1 WSFB-1 P-1 P-1 P-1 P-1 ACT-1
H07 MECH / ELEC SEALED
CONCRETE
RB-1 P-1 P-1 P-1 P-1 EXPOSED
STRUCTURE
H08 HR LINKS CPT-1 RB-1 P-1 P-3 P-1 P-1 ACT-1
H08A TELECOM.
CLOSET
SDT-1 RB-1 P-6 P-6 P-6 P-6 ACT-1
H09 CORRIDOR LVT-1 RB-1 P-1 P-1 P-1 P-1 ACT-1
H10 WORK
LEADER'S
OFFICE
CPT-1 RB-1 P-2 P-1 P-1 P-1 ACT-1
H11 TOILET PT-1 PTB-1 PT-2 PT-2 PT-2 PT-2 ACT-1
H12 FOREMAN'S
OFFICE
CPT-1 RB-1 P-1 P-1 P-5 P-1 ACT-1
FINISH GENERAL NOTES
WALL PROTECTION GENERAL NOTES
EQUIPMENT GENERAL NOTES
SIGNAGE GENERAL NOTES
Scale: No Scale
SIGNAGE DETAILS
DRAWING ADDENDUM 09/13/2023
24514
LICENSED
ARCHITECT
DocuSign Envelope ID: 51161433-2019-45B2-B646-8FF00F896EAD
REF.
1.1
A.1
A.8
C.9
2.1 2.9
GRAVE
LOCATOR
A.0
2.3 2.72.5 3 4
C
D.5
A.4
C.6
MECH./
ELEC.
STAFF
TOILET
108 HAC
STAFF
TOILET
STORAGE
DIRECTOR'S
OFFICE
OFFICE
OFFICE
RECEPTION
GRAVE
LOCATOR
RM.
101A
LOBBY
MEN'S
WOMEN'S
CONFERENCE
ROOM
WORK
STATIONS
CORRIDOR
CORRIDOR
RECORDS
STORAGE
STORAGE
LUNCH
ROOM
TR
OPERATIONS
CORRIDOR
CORRIDOR
I-201
I-201
I-201
I-201
I-201
HAC
# KEY NOTES:
Dwg of
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 001
I-101R
FIRST FLOOR FINISH, SIGNAGE, AND
WALL PROTECTION PLAN -
ADMINISTRATION BLDG.
KLCEMD 58 186JULY 28, 2023
X
BID DOCUMENTS
22-023
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRS
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
N O
R T
H0 4 8 16
1 CG-1, PROVIDE AND INSTALL FULL HEIGHT
CORNER GUARD
2 PAINT P-2
3 PAINT P-3
4 PAINT P-4
5 PRIMARY ROOM IDENTIFICATION SIGNAGE -
EXTERIOR GRADE
6 SECONDARY ROOM IDENTIFICATION
SIGNAGE - EXTERIOR GRADE
7 GRAVE SITE LOCATOR SIGNAGE - EXTERIOR
GRADE, COORDINATE WITH DAYTON
CEMETARY DIRECTOR ON VERBAGE
8 SECONDARY ROOM IDENTIFICATION
SIGNAGE
9 PRIMARY ROOM IDENTIFICATION SIGNAGE
10 RESTROOM (UNISEX) ADA IDENTIFICATION
SIGNAGE
11 WOC-1 TO LVT-1 TRANSITION
Scale: 1/4" = 1'-0"
FIRST FLOOR FINISH AND WALL PROTECTION PLAN -
ADMINISTRATION BLDG.
DRAWING ADDENDUM 09/13/2023
24514
LICENSED
ARCHITECT
I-431R1D
1A
1B
1C
I-431R 1F
1G
ADA
CHANGE
ROOM
H05
LOCKER
ROOM
H06
A5145
A5145
A1080
A1030M
A1030MA1030MA1030M
A1030M
A1030M
A1030M
A1030M
A1030M
A1030MA1030MA1030MA1030MA1030MA1030MA1030MA1030MA1030MA1030MA1030MA1030M
A1030M
A1030M
A1030M
A1030M
A1030M
A1030M
A1030M
A1030M
U0005
U0005
F3200
A1030MA1030MA1030M
U0005
F3200
A1030MA1030MA1030M A1030MA1030M A1030MA1030MA1030MA1030MA1030MA1030M A1030MA1030M A1030MA1030MA1030M A1030MA1030MA1030MA1030M
A1030MA1030MA1030MA1030MA1030MA1030MA1030M
A5145 A5145
U0005
A1080
A1080
I-431R2D
2A
2B
2C
STAFF
TOILET
A5075
A1067 A5082
F2010
A5109
A5200
A5090
A5145 U0020
A1067
A5082
A5109
A5109
A5200 A5090
U0020
A5145
# KEY NOTES:
Dwg of
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 001
I-431R
ENLARGED TOILET PLANS AND
ELEVATIONS
KLCEMD 68 186JULY 28, 2023
X
BID DOCUMENTS
22-023
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRS
1 METAL COVE TRANSITION FLOOR TO WALL
TILE
2 PT-2, PORCELAIN TILE
3 WSFB-1, WELDED SHEET FLOOR BASE
4 EP-1, EPOXY PAINT
6 RESB-1, RESINOUS INTEGRAL COVE BASE
Scale: 1/2" = 1'-0"
ENLARGED LOCKER ROOM - H06 / ADA CHANGE ROOM -
H05
Scale: 1/2" = 1'-0" 1A
LOCKER ROOM - H06 - NORTH
Scale: 1/2" = 1'-0" 1B
LOCKER ROOM - H06 - EAST
Scale: 1/2" = 1'-0" 1C
LOCKER ROOM - H06 - SOUTH
Scale: 1/2" = 1'-0" 1D
LOCKER ROOM - H06 - WEST
Scale: 1/2" = 1'-0" 1F
ADA CHANGE ROOM - H05 - EAST
Scale: 1/2" = 1'-0" 1G
ADA CHANGE ROOM - H05 - SOUTH
Scale: 1/2" = 1'-0"
ENLARGED STAFF TOILET - 110
Scale: 1/2" = 1'-0" 2A
STAFF TOILET - 110 - NORTH
Scale: 1/2" = 1'-0" 2B
STAFF TOILET - 110 - EAST
Scale: 1/2" = 1'-0" 2C
STAFF TOILET - 110 - SOUTH
Scale: 1/2" = 1'-0" 2D
STAFF TOILET - 110 - WEST
NORTH
0 4 8 16
N O
R T
H0 4 8 16
DRAWING ADDENDUM 09/13/2023
24514
LICENSED
ARCHITECT
MEN'S
LOCKER
ROOM
TOILET/
SHOWER
I-432R
1E
I-432R1D
1F1H
1G
1A
1B
1C
I-2018
A5145
A5145
A5145
U0004U0004U0004 U0004U0004U0004
U0004
U0004
U0004
U0004
U0004
U0004
U0004
U0004
U0004
U0004
U0004
U0004 U0004
A5082
A1067
A5075
A1067
A5082
F2010
A5170
A5170
A5200
A5030
A5030
A5110M
A5110M
A5200
U0021
A5145
A5145
U0004U0004 U0004U0004
A5145
U0004
M126A
U0021
TOILET/ SHOWER 124
U0004 U0004 U0004 U0004
U0004 U0004U0004 U0004 U0004 U0004U0004 U0004 U0004 U0004 U0004
A5170
A5030
MEN'S LOCKER ROOM 125
A5145 A5145A5082
A5170A5170
A5110M A5110M
TP
A5030A5030
A5109
A5200
A1067 A1067A5075 A5082A5082
A5109
A5200
A5200
# KEY NOTES:
Dwg of
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
VA FORM 08 - 6231
321 4 5 6 7 8 9 10
CLIN 001
I-432R
ENLARGED TOILET PLANS AND
ELEVATIONS
KLCEMD 69 186JULY 28, 2023
X
BID DOCUMENTS
22-023
BID DOCUMENTS
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRS
1 METAL COVE TRANSITION FLOOR TO WALL
TILE
2 PT-2, PORCELAIN TILE
3 WSFB-1, WELDED SHEET FLOOR BASE
4 EP-1, EPOXY PAINT
6 RESB-1, RESINOUS INTEGRAL COVE BASE
Scale: 1/2" = 1'-0"
ENLARGED MEN'S LOCKER - 125 / TOILET / SHOWER - 124
Scale: 1/2" = 1'-0" 1A
MEN'S LOCKER - 125 - NORTH
Scale: 1/2" = 1'-0" 1B
MEN'S LOCKER - 125 - EAST
Scale: 1/2" = 1'-0" 1C
MEN'S LOCKER - 125 - SOUTH
Scale: 1/2" = 1'-0" 1D
MEN'S LOCKER - 125 - WEST
Scale: 1/2" = 1'-0" 1E
TOILET / SHOWER - 124 - NORTH
Scale: 1/2" = 1'-0" 1F
TOILET / SHOWER - 124 - EAST
Scale: 1/2" = 1'-0" 1G
TOILET / SHOWER - 124 - SOUTH
Scale: 1/2" = 1'-0" 1H
TOILET / SHOWER - 124 - WEST
N
AREA OF WORK
SCOPE OUTLINE
KEY PLAN
SCALE: NO SCALE
NORTH
0 4 8 16
DRAWING ADDENDUM 09/13/2023
24514
LICENSED
ARCHITECT
W W
W
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
ST ST ST ST
ST
ST
ST
ST
ST
ST
ST
ST
ST
S
S
S
S
S
S
S
S
S
S
S
W W
W W
LP#308
LP#309
LP#304
LP#305
LP#306
LP#311
LP#312
LP#315
ES
x
ES x
ES x
ESx
ESx
ES
x
ES
x
ESx
ESx
ES
x
ES
xST
ST
ST ST
ST
ST
ST
ST
ST
LIMITS OF
CONSTRUCTION
LIMITS OF
CONSTRUCTION
LIMITS OF
CONSTRUCTION
LIMITS OF CLEARING
/ GRADING
LIMITS OF CLEARING /
GRADING
LIMITS OF CLEARING
/ GRADING
LIMITS OF CLEARING /
GRADING
LIMITS OF CLEARING /
GRADING
PR. RETAINING WALL W/ RAILING
(SEE SHEETS CG112 & CG113 FOR DETAILS)
PR. RETAINING WALL W/ RAILING
(SEE SHEETS CG112 & CG113 FOR DETAILS)
FOREBAY 1
FOREBAY 2
TIE INTO EX.
CURB & GUTTER
TIE INTO EX.
CURB & GUTTER
EXTENDED
DETENTION
POND
FOREBAY 3
15" HDPE
15" HDPE
15" HDPE
EX. 12" RCP
4A
4B
18" HDPE
15" HDPE15" HDPE
24" HDPE
24" HDPE
15" HDPE
24" HDPE
15" HDPE
15" HDPE
15" HDPE
SS
SS
SS
SS
SS
SS
SS
SS
SS
A
B
A1
EX.
E1
EX.
E
C
8" SAN SEW
EX. 24" SAN SEW
EX. 24" SAN SEW
8" SAN SEW
8" SAN SEW
8" S
AN
SE
W
EX. 24" SAN SEW
4" SAN LAT EX. 8" SAN SEW
5A
EX
. 8"
CL
AY
2B
SS6" SAN
LAT
44 43
W x
W
9+
+0
+0
12+
+0
14+00
+6
12'
' DIP WL
18" HDPE
15" HDPE
EX. 12" CLAY
EX1
EX
. 2
4"
CL
AY
EX
. 2 4"
CL
AY
33.96'-6" PVC @ 7.07%
12.09'-6" PVC @ 3.31%
C/O INV.=903.00INV.=905.40
INV.=905.40
C/O INV.=905.34
INV.=905.40
C/O INV.=905.10
5.19'-6" PVC @ 1.16%
22.25'-6" PVC
@ 1.08%9.29'-6" PVC @ 3.23%
8.83'-6" PVC @ 10.19%
8.58'-6" PVC @ 12.81%
32.99'-6" PVC
@ 1.21%
C/O INV.=904.30
INV.=905.40
C/O INV.=904.70 INV.=905.40
C/O INV.=905.10
INV.=905.40
33.14'-6" PVC @ 1.21%
8.58'-6" PVC @ 8.15%
9.95'-6" PVC @ 3.01%
10' TYPE C
ROCK RIP-RAP
2C
W
EX. 18" CLAY
18"
HDPE
2A1C
1B1A
18" HDPE
" H
DP
E
EX
. 1
2'' W
L
18" HDPE
EX. 18" HDPE 18" HDPE
1111A11B 12" RCP CL IV
FIELD CONNECT INTO PIPE
INV.=900.05
12'
' DIP WL
34.61'-6" PVC
@ 12.27%
W
EX
. 2
4"
CL
AY
SWM1
45A
12" RCP CL IV
12" HDPE
EX. 12" CLAY
10' TYPE C
ROCK RIP-RAP
2.5" SERVICE LINE
2'' SERVICE
LINE
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
MONTGOMERY COUNTY, OHIO
810CM3030
JULY 28, 2023 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRSIntegrity Federal Services
(304) 725-8456
Fil e P ath : G
:\P
RO
JE
CT
\S
BU
\33
-1
1 D
AY
TO
N
NA
TI
ON
AL
C
EM
ET
ER
Y\
EN
GI
N\
PL
AN
S\
CS
4.D
W G
GORDON - The LA Group Joint Venture, LLC The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
AMENDMENT DRAWING 001 09-13-20231
CU101R
SITE UTILITY PLAN
MD RPP
KEY NOTE LEGEND
KEY MAP
(NOT TO SCALE)
2 3 4 5
6 7 8
KEY NO. DESCRIPTION
1 ODOT CATCH BASIN #6
DETAIL/PG.
2 ODOT CATCH BASIN #2A
3 STORM SEWER MANHOLE
SANITARY SEWER MANHOLE5
WATERLINE BEND6
WATER SERVICE CONNECTION7
FIRE HYDRANT
4 ADS END SECTION
REPLACE STORM SEWER LINE. NEW LINE TO BE SAME
DIAMETER PIPE AND HAVE SAME INVERTS AS
REMOVED LINE.
CONNECT TO EX. 12" WATER LINE10
LOWER RIM OF EXISTING STORM STRUCTURE TO ELEVATION
898.50. REPLACE COVER WITH INLET FRAME AND GRATE.11
POND OUTLET STRUCTURE12
STORM CLEANOUT13
AutoCAD SHX Text
EX. BUILDING 8,939 SF (HT=20.0')
AutoCAD SHX Text
EX. BUILDING 2,356 SF (HT=20.0')
AutoCAD SHX Text
EX. SHED 103 SF
AutoCAD SHX Text
EX. SHED 78 SF
AutoCAD SHX Text
FUEL TANK
AutoCAD SHX Text
OIL TANK
AutoCAD SHX Text T
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
EH
AutoCAD SHX Text
ST
AutoCAD SHX Text
RIM=911.02
AutoCAD SHX Text (35930)
AutoCAD SHX Text
(35901) RIM=912.90
AutoCAD SHX Text
(35902) RIM=912.88
AutoCAD SHX Text
(35903) RIM=898.67
AutoCAD SHX Text
RIM=898.57
AutoCAD SHX Text (35904)
AutoCAD SHX Text
RIM=907.56
AutoCAD SHX Text (35905)
AutoCAD SHX Text
RIM=907.56
AutoCAD SHX Text (35906)
AutoCAD SHX Text
RIM=914.68
AutoCAD SHX Text (35908)
AutoCAD SHX Text
ST
AutoCAD SHX Text
RIM=916.29
AutoCAD SHX Text (35913)
AutoCAD SHX Text
(35914) RIM=916.18
AutoCAD SHX Text
RIM=916.13
AutoCAD SHX Text (35915)
AutoCAD SHX Text
RIM=901.61
AutoCAD SHX Text (35925)
AutoCAD SHX Text
ST
AutoCAD SHX Text
RIM=905.63
AutoCAD SHX Text (35927)
AutoCAD SHX Text
RIM=911.00
AutoCAD SHX Text (45923)
AutoCAD SHX Text
ST
AutoCAD SHX Text
RIM=913.12
AutoCAD SHX Text (45931)
AutoCAD SHX Text
ST
AutoCAD SHX Text
RIM=913.08
AutoCAD SHX Text (45932)
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text
CABLE BOX
AutoCAD SHX Text
SHUT-OFF VALVE
AutoCAD SHX Text
ELEC BOX
AutoCAD SHX Text
6' BRICK WALL
AutoCAD SHX Text
MH
AutoCAD SHX Text
RIM=914.24
AutoCAD SHX Text (35304)
AutoCAD SHX Text
MH
AutoCAD SHX Text
RIM=913.50
AutoCAD SHX Text (35305)
AutoCAD SHX Text
MH
AutoCAD SHX Text
MH
AutoCAD SHX Text
VLT
AutoCAD SHX Text
VLT
AutoCAD SHX Text
RIM=
AutoCAD SHX Text (20683)
AutoCAD SHX Text
VLT
AutoCAD SHX Text
RIM=
AutoCAD SHX Text (20687)
AutoCAD SHX Text
VLT
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text S
AutoCAD SHX Text
RIM=914.12
AutoCAD SHX Text (35911)
AutoCAD SHX Text S
AutoCAD SHX Text
(35912) RIM=914.27
AutoCAD SHX Text S
AutoCAD SHX Text
RIM=912.91
AutoCAD SHX Text (45592)
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text 912.42
AutoCAD SHX Text
FFE
AutoCAD SHX Text 912.42
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.33
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.35
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.26
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.32
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.30
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.68
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.76
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.20
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.24
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.33
AutoCAD SHX Text
FFE
AutoCAD SHX Text 913.80
AutoCAD SHX Text
FFE
AutoCAD SHX Text
WISCONSIN AVE
AutoCAD SHX Text
NEW MEXICO PL
AutoCAD SHX Text
HAWAII PL
AutoCAD SHX Text
WISCONSIN AVE
AutoCAD SHX Text
WISCONSIN AVE
AutoCAD SHX Text
MCMAHON AVE
AutoCAD SHX Text
W THIRD ST
AutoCAD SHX Text
EH
AutoCAD SHX Text S
AutoCAD SHX Text APPROX. POTENTIAL LOCATION OF BURIED STORM STRUCTURE & PIPE LINE CONNECTION (PER KZF INCORPORATED, JOB NO. 810CM3012, DATED: 6/30/98)
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
RIM=898.38
AutoCAD SHX Text (36024)
AutoCAD SHX Text
ADMIN BUILDING
AutoCAD SHX Text
1-STORY SLAB= 907.40 ±3,738 G.F.A.
AutoCAD SHX Text
HONOR GUARD BUILDING
AutoCAD SHX Text
1-STORY SLAB= 908.40 ±1,534 G.F.A.
AutoCAD SHX Text
COVERED SHED
AutoCAD SHX Text
SLAB= S.O.G ±588 G.F.A.
AutoCAD SHX Text
GRAPHICAL SCALE: 1" = 30'
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
AutoCAD SHX Text
EX. BUILDING 2,435 SF (HT=20.0')
AutoCAD SHX Text
EX. BUILDING 8,939 SF (HT=20.0')
AutoCAD SHX Text
EX. BUILDING 2,356 SF (HT=20.0')
AutoCAD SHX Text
FUEL TANK
AutoCAD SHX Text
OIL TANK
AutoCAD SHX Text T
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
YD
AutoCAD SHX Text
YD
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
DS
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text
CO
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text I
AutoCAD SHX Text T
AutoCAD SHX Text
35121 FMON
AutoCAD SHX Text
35122 FMON
AutoCAD SHX Text
35150 FMON
AutoCAD SHX Text
103 FMON
AutoCAD SHX Text
101 FMON
AutoCAD SHX Text
35325 FMON
AutoCAD SHX Text
102 SMON
AutoCAD SHX Text
1 CP SIR
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
ST
AutoCAD SHX Text
AutoCAD SHX Text
CU561
AutoCAD SHX Text
AutoCAD SHX Text
CU561
AutoCAD SHX Text
AutoCAD SHX Text
CU562
AutoCAD SHX Text
AutoCAD SHX Text
CU501
AutoCAD SHX Text
AutoCAD SHX Text
CU531
AutoCAD SHX Text
AutoCAD SHX Text
CU531
AutoCAD SHX Text
AutoCAD SHX Text
CU531
AutoCAD SHX Text
AutoCAD SHX Text
CU562
AutoCAD SHX Text
AutoCAD SHX Text
CJ501
AutoCAD SHX Text
AutoCAD SHX Text
CU562
Project Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
A
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9
MONTGOMERY COUNTY, OHIO
810CM3030
JULY 28, 2023 Dwg. of
Office of Design and Construction
Service U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number
BID DOCUMENTS
VA FORM 08 - 6231
321 4 5 6 7 8 9
DAYTON NATIONAL CEMETERY
PIC/ADMIN BLDG, REPLACE COMMITTAL
SHELTER B, AND ROAD REPAIRSIntegrity Federal Services
(304) 725-8456
Fil eP ath :G
:\P
RO
JE
CT
\S
BU
\33
-1
1D
AY
TO
N
NA
TI
ON
AL
CE
ME
TE
RY
\E
NG
IN
\P
LA
NS
\C U5
.D
W G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518) 587-8100
AMENDMENT DRAWING 001 09-13-20231
CU562R
STORM SEWER DETAILS
6" Ø PVC STORM DRAIN
6" PVC RISER
6" PVC 45° WYE
AND FITTING
HEAVY DUTY CAST IRON
FRAME & COVER
6" PVC
SCREW CAP
18" DIA. x 6" THICK
CONCRETE COLLAR
1 2
A
B
46 SF
S1
STORAGE
CAST-IN-PLACE
CONCRETE SLAB
PERIMETER
MANUFACTURED STONE
VENEER O/ CONCRETE
COLUMN
BENCH SEATING
CONCRETE SLAB CONTROL JOINTS
S1
A-301
A-301
6'-0" 4'-0" 6'-0"
2'-0" 4'-8" 20'-0" 12'-8"
2'-0" 6'-0" 17'-4" 6'-0" 8'-0"
4'-8" 1'-4"
ROOF OVERHANG
1'-1" 5'-10" 1'-1"
M .O
1'-4" 4'-8"
SEE SITE PLAN FOR
CONTINUATION
SEE SITE PLAN FOR
CONTINUATION
A-301
A-201
A-201
A-201
A-201
39'-4"
REFLECTED CEILING PLAN LEGEND
DENOTES GWB
SOFFIT/CEILING
CEILING HEIGHT
DESIGNATION (WHEN
HEIGHT VARIES FROM
TYPICAL)
FLUORESCENT
LIGHT FIXTURE
2'x4' SURFACE MOUNT
LED FIXTURE
EQ. A EQ. A
E Q
B
E Q
B
EXIT SIGN (SHADED
AREA INDICATES
DIRECTION OF EGRESS)
SUPPLY DIFFUSER
RETURN GRILL
PENDANT
MOUNTED LIGHT
DOWN LIGHT
FIXTURE
CEILING CONTRACTOR TO MEASURE EACH CEILING AREA AND
ESTABLISH A CEILING LAYOUT TO BALANCE BORDER WIDTHS AT
OPPOSITE EDGES OF EACH ROOM. AVOID USE OF LESS-THAN 6"
TILES.
A.F.F.10' 6"
PERIMETER
RECESSED WALL
SLOT LIGHT FIXTURE
FIRE ALARM STROBE
FAA
FIRE ALARM ANNUCIATOR
F
FIRE ALARM PULL STATION
FIRE ALARM
STROBE LIGHT
S
H
HEAT DETECTOR
SMOKE DETECTOR
FIRE ALARM / HORN /
STROBE LIGHT - WALL
MOUNTED
FIRE ALARM / HORN /
STROBE LIGHT - CEILING
MOUNTED
SPRINKLER HEAD
SPRINKLER HEAD
2'x4' LAY-IN LED
2'X2' ACT CEILING
EXHAUST GRILL
DENOTES WOOD FINISH
CEILING
CEILING HATCH
CONCRETE CAP
(ADA CHANGE ROOM IN
HONOR GUARD BLDG)
SUSPENDED FAN
1 2
A
B
4" / 12"
4" / 12"
ASPHALT SHINGLE ROOFING
CONTINUOUS ALUMINUM
GUTTER O/ FASCIA BD.
R
ID
G
E RIDGE
H
IP
VA
LL
EY
H
IP
H
IP
H
IP
H
IP
V
ALLE
Y
H
IP
A-301
A-301
20'-0"
4'-8" 4'-8"
A-301
A-301
4" / 12"
1 2
A
B
ASSEMBLY
SPACE
STORAGE
SUSPENDED FAN
RECESSED CAN LIGHTING
HSS COLUMN STRUCTURE
MANUFACTURED STONE VENEER O/
CMU COLUMN WALL
BEAM STRUCTURE
(ABOVE ENCLOSURE)
ALUM. VENTED SOFFIT
ENGINEERED SYNTHETIC
WOOD SYSTEM
EXTERIOR GRADE
PLYWOOD
A-301
A-301
9' - 8"
9' - 8"
ACT
2x2
9' - 10"
9' - 8"
8' - 8"
9' - 10"
BEAM ENCLOSURE +8' - 8"
REINFORCEMENT -
SEE STRUCTURAL
8" CMU LINTEL - SEE
STRUCTURAL
DOOR & FRAME -
SEE SCHEDULE
CAULK BOTH
SIDES (TYP)
GROUT FRAME
SOLID
SEE DOOR
SCHEDULE
ASHLAR STONE
MASONRY
1" AIR SPACE
CAULK BOTH SIDES OF
DOOR - CONTINUOUS
8" CMU, FULLY
GROUTED
DOOR & FRAME - SEE
SCHEDULE
REINFORCEMENT - SEE
STRUCTURAL
GROUT FRAME
SOLID
BULLNOSE
CORNERS - TYPICAL
ASHLAR STONE
MASONRY
1" AIR SPACE
F1
S E
E S
C H
E D
U L E
SCHEDULE
SEE
SCHEDULE
SEE
2" 2"
SCHEDULE
SEE
S E
E S
C H
E D
U L E
Dwg of
ACG Project Number
GORDON - The LA Group Joint Venture, LLC
The LA Group 40 Long Alley Saratoga Springs, NY 12866
(518) 587-8100
INTEGRITY FEDERAL SERVICES
148 S. Queen Street, Suite 201 Martinsburg, WV 25401
(304) 725-8456
Location
Issue Date
Project Number
Drawing Number
Project Title
Checked Drawn
MONTGOMERY COUNTY, OHIO
810CM3030Office of Design and Construction
Service
U.S. Department of Veterans Affairs
ARCHITECT/ENGINEER OF RECORD STAMPCONSULTANT
Revisions: Date:
Drawing Title
Approved: Project Director
Phase
Building Number Integrity Federal Services
(304) 725-8456
F ile
P at h:
L
P
R O
JE
C
T S
E
N G
\2
P
R O
JE
C
T S
\2 2-
3-
IF
S
-N C
A -D
A Y
T
M E
T E
R Y
R E
N O
V -O
H \R
V T
\C O
N T
E N
T \T
IT
LE
B
LO
C K
S \8
C
M
_G
-T T
LB
E
M P
T Y
.D W
G
Apogee Consulting Group
(919) 858-7420
Foresite Group
(770) 368-1399
The LA Group
(518)…