DD3 Pre-Final Drawings Plumbing.pdf
PDF 2 MB Posted
- Solicitation number
- Not on record
About this file
This document appears to be a set of pre-final drawings for the Dry Dock 3 Repair and Modernization project at the Norfolk Naval Shipyard in Portsmouth, Virginia. The drawings provide detailed plumbing plans, schedules, and riser diagrams for the project. Key details include:
The project involves repairs and modernization of Dry Dock 3 at the Norfolk Naval Shipyard. The plumbing systems include domestic cold water, domestic hot water, sanitary sewer, storm drainage, and vent piping. Major components include water heaters, pumps, backflow preventers, floor drains, roof drains, and piping. The drawings provide a comprehensive set of details, schedules, and riser diagrams to support the plumbing design.
View the file
Other files
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BE
RT
H
BE
RT
H
BE
RT
H
DRY DOCK 2
BE
RT
H
DRY DOCK 3
BERTH 16
BERTH 17
BE
RT
H
BERTH 19
DRY DOCK 4
EMH
174-A
894 893
AR
MS
TE
AD
A V.
AR
NS
TE
AD
A
V.BERRIEN ST.
STEVENS ST.
PO
RT
C
EN
TR
E
PK
W
Y/
OL
D
MA
YO
A
V.
HUGHES ST.BR
OW
N
AV
TRUXTON ST.
CREIGHTON ST.
RE
NS
HA
W
A
V.BERRIEN ST.
STEVENS ST.
GA
TE
Q
PIC
NI
C
GATE P
GATE R
LOCATION MAP
SCALE: 1" = 200'
VICINITY MAP
NTS
NORFOLK NAVAL SHIPYARD ~ PORTSMOUTH, VIRGINIA
NAVAL FACILITIES ENGINEERING SYSTEMS COMMAND ~ ATLANTIC
BES TNT2 WWW
TI
TL
E
SH
EE
T
G-001
AS NOTED
PROJECT
SITE
CHESAPEAKE
CHESAPEAKE BAY
PORTSMOUTH
NORFOLK
VIRGINIA
LITTLE CREEK
U.S. NAVAL
AMPHIBIOUS BASE
BEACH
NORTH
PROJECT LOCATION
NORTH
CONTRACT NO. N40085-18-D-1100
FI
LE
N
AM
E:
Q
:\N
OR
\10
0-
\20 C
AD
D\
_A cti ve \_D
RY
DP
DD
3-
0-
RM
DD
3\D
RY
DP
DD
3-
0- G-
1.d wg L
AY
OU
T
NA
ME
: T
IT
LE
S
HE
ET
P
LO
TT
ED
: T hu rsd ay , O cto be r 2 6, 1:3
4p m
US
ER
: tt ho mp so n
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW
S Y
M D
E S
C R
IP
TI
O N
D A
TE
A
P P
R
DRAWFORM REVISION: 25 AUGUST 2020
CHK
SATISFACTORY TO
APPROVED
ACTIVITY
DATE
FOR COMMANDER NAVFAC
SEAL
A/E INFO
OF
EPROJECT NO.:
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL SUBMITTAL - 2023/10/26
D E
P A
R
TM
E N
T O
F
TH
E N
A V
Y N
A V
A L
FA
C
IL
IT
IE
S
E N
G
IN
E E
R
IN
G S
Y S
TE
M
S C
O M
M A
N D
NA
VF
AC
A
TL
AN
TI
C
LA
FA
YE
TT
E
RI
VE
R
AN
NE
X
- N
OR
FO
LK
, V
A
NO
RF
O
LK
N
AV
AL
S
HI
PY
AR
D
PO
RT
SM
O
UT
H, V
IR
G
IN
IA
DR
Y
DO
CK
R
EP
AI
R
AN
D M
O
DE
RN
IZ
AT
IO
N
CAH/ABL
1715740
N O
T
FO
R
CO
N
ST
RU
CT
IO
N
P R
E L
IM
IN
A
R Y
UN
CL
AS
SI
FI
ED
UNCLASSIFIED
UNCLASSIFIED
DRY DOCK 3 REPAIR AND MODERNIZATION
AAV AIR ADMITTANCE VALVE
ABA ARCHITECTURAL BARRIERS ACT
AC ABOVE CEILING
AFF ABOVE FINISHED FLOOR
AG AIR GAP
AP ACCESS PANEL
ARCH ARCHITECTURAL
BFF BELOW FINISHED FLOOR
BFP BACKFLOW PREVENTER
BG BELOW GRADE
BOP BOTTOM OF PIPE
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CD CONDENSATE DRAIN
CHT COLLECTION, HOLDING AND TRANSFER
CO CLEANOUT
COM COMPRESSOR
CONC CONCRETE
CPVC CHLORINATED POLYVINYL CHLORIDE
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
DHWR DOMESTIC HOT WATER RETURN
DN DOWN
DT DRAIN THROUGH
DWG DRAWING
EA EACH
EER ENERGY EFFICIENCY RATIO
EL ELEVATION
ELB ELBOW
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXIST EXISTING
F FAHRENHEIT
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FFD FUNNEL FLOOR DRAIN
FLA FULL LOAD AMPS
FM FLOW METER
FR FROM
FS FLOOR SINK
FT FEET
FT WC FEET OF WATER COLUMN
GAL GALLON
GCO GROUND CLEANOUT
GFCI GOVERNMENT FURNISHED,
CONTRACTOR INSTALLED
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HB HOSE BIBB
HC HANDICAP ACCESSIBLE
HD HEAVY DUTY
HP HORSEPOWER
HR HOUR
HWCP HOT WATER CIRCULATING PUMP
HX HEAT EXCHANGER
HY HYDRANT
HZ HERTZ
IAW IN ACCORDANCE WITH
IM ICE MAKER
PLUMBING ABBREVIATIONS
IN INCHES
INV ELE INVERT ELEVATION
IN WC INCHES OF WATER COLUMN
IMB ICE MAKER BOX
KW KILOWATT
L LAVATORY
LBS POUNDS
MAX MAXIMUM
MBH 1000 BTUH
MIN MINIMUM
MFR MANUFACTURER
MS MOP SINK
N NORTH
NC NORMALLY CLOSED
NG NATURAL GAS
NGS NATURAL GAS SUPPLIER
NIC NOT IN CONTRACT
NO NUMBER, NORMALLY OPEN
NTS NOT TO SCALE
OD OVERFLOW DRAIN
ODS OVERFLOW DRAIN SPOUT
PH PHASE
PRS PRESSURE REDUCING STATION
PRV PRESSURE REDUCING VALVE
PSI POUNDS PER SQUARE INCH
PSIG POUNDS PER SQUARE INCH GAUGE
PVC POLYVINYL CHLORIDE
RL ROOF LEADER
RD ROOF DRAIN
REF REFRIGERATOR
RM RADON MITIGATION
RPM REVOLUTIONS PER MINUTE
RPZ REDUCED PRESSURE ZONE ASSEMBLY
RUB REFRIGERATOR UTILITY BOX
S SINK
SCH SCHEDULE
SD STORM DRAIN
SH SHOWER
SIM SIMILAR
SS SANITARY SEWER
TD TRENCH DRAIN
TMV THERMOSTATIC MIXING VALVE
TOP TOP OF PIPE
TPM TRAP PRIMER MANIFOLD
TYP TYPICAL
UON UNLESS OTHERWISE NOTED
UR URINAL
V VENT
VS VENT STACK
VTR VENT THRU ROOF
W WASTE
WC WATER CLOSET
WCO WALL CLEANOUT
WHA WATER HAMMER ARRESTOR
WH WALL HYDRANT
WS WASTE STACK
WUB WASHER UTILITY BOX
WVC WET VACUUM CLEANING
YCO YARD CLEAN OUT
YH YARD HYDRANT
° DEGREE
PLUMBING LEGEND
DOMESTIC HOT WATER PIPNG (DHW)
DOMESTIC COLD WATER PIPING (DCW)
DOMESTIC HOT WATER RETURN PIPING (DHWR)
SOIL, WASTE OR SANITARY SEWER PIPING (W)
NATURAL GAS PIPING (G)
RAIN LEADER
DOWNWARD SLOPE
VENT PIPING
GATE VALVE (HORIZONTAL AND VERTICAL)
TEMPERATURE AND PRESSURE RELIEF VALVE
CHECK VALVE
UNION
EXTERIOR WALL HYDRANT (WH)
HOSE BIBB (HB)
FLOOR DRAIN (FD)
WALL CLEANOUT (WCO)
FLOOR CLEANOUT (FCO)
CLEANOUT TO GRADE (COTG)
WATER HAMMER ARRESTOR
(PDI SIZE FIXTURE UNIT RATING 1-11)
VENT THRU ROOF (VTR)
FLOOR DRAIN MARK
(SEE SCHEDULE ON SHEET P-???)
PLUMBING FIXTURE MARK
(SEE SCHEDULE ON SHEET P-???)
WATER HEATER MARK
(SEE SCHEDULE ON SHEET P-???)
THIN LINE WEIGHT INDICATES EXISTING
ITEM TO REMAIN
PIPE TURNING DOWN
HEAVY LINE WEIGHT INDICATES NEW
WORK TO BE PROVIDED
ROOF DRAIN
HEAVY DASHED LINE WEIGHT INDICATES
EXISTING ITEM TO REMOVE, REFER TO
DEMOLITION NOTES.
G
RL
V
P-1
FD-1
WH-1
PIPE TURNING UP
(A)
RD
1. THE GENERAL PLUMBING NOTES APPLY TO PLUMBING DRAWINGS IN THIS SET.
2. WORK MUST COMPLY WITH EQUIPMENT MANUFACTURER'S INSTRUCTIONS.
3. PROVIDE COMPLETE AND OPERABLE PLUMBING SYSTEMS AS INDICATED AND REQUIRED BY
UFC 3-420-01.
4. PROVIDE PLUMBING FIXTURE AND EQUIPMENT WITH ACCESSIBLE STOPS.
5. FIELD VERIFY DIMENSIONS.
6. CLEANOUTS MUST BE FULL SIZE OF PIPE.
7. COORDINATE WORK WITH OTHER TRADES. RESOLVE CONFLICTS PRIOR TO WORK.
IMMEDIATELY NOTIFY CONTRACTING OFFICER IF AN UNRESOLVABLE CONFLICT IS PRESENT.
DO NOT PROCEED WITH WORK UNTIL DIRECTED BY CONTRACTING OFFICER.
8. PLUMBING VENTS WITH A 10'-0" RADIUS OF EXHAUST VENTS MUST BE EXTENDED TO A
HEIGHT OF 2'-0" ABOVE EXHAUST VENT CROWN.
9. MOUNT HOSE BIBBS 18" ABOVE FINISHED FLOOR.
10. MOUNT WALL HYDRANTS 24" ABOVE FINISHED GRADE.
11. SLOPES AND INVERT ELEVATIONS OF INTERIOR PIPING MUST BE ESTABLISHED PRIOR TO
INSTALLATION OF PIPING WORK. MINIMUM CODE COMPLIANT SLOPES MUST BE MAINTAINED
THROUGHOUT SYSTEM. ROUTE PIPING TO AVOID CONFLICT WITH OTHER TRADES.
12. COORDINATE WITH ARCHITECTURAL WORKING DRAWINGS PRIOR TO ROUGHING-IN PLUMBING
FIXTURES.
13. DESIGN IS SCHEMATIC IN NATURE. NOT ALL SYSTEM COMPONENTS, ELBOWS, TRIM HARDWARE, OFFSETS, AND FITTINGS ARE SHOWN. PROVIDE SYSTEM COMPONENTS, ELBOWS, TRIM
HARDWARE, OFFSETS, FITTINGS, AND ACCESSORIES FOR A COMPLETE UFC 3-420-01, CODE
COMPLIANT OPERABLE SYSTEM.
14. PROVIDE DEEP SEAL TRAPS FOR FLOOR DRAINS.
15. PROVIDE TRAP PRIMERS ON DRAINS AS SHOWN IN DRAWINGS.
16. PIPING MUST BE CONCEALED ABOVE CEILING OR IN WALLS OR CHASES UNLESS OTHERWISE
NOTED.
17. PROVIDE ACCESS PANELS FOR CONCEALED VALVES WITHIN SOLID NON REMOVABLE
COVERINGS.
18. EXPOSED PIPING MUST LOCATED AS HIGH AS POSSIBLE UNLESS OTHERWISE NOTED. PROVIDE
RISES, DROPS AND OFFSETS AS REQUIRED.
19. PROVIDE A FACTORY FABRICATED PIPE LABELS PER SPECIFICATION 22 00 00.
20. SEE PLUMBING FIXTURE SCHEDULE ON P-652 SERIES SHEETS OR PIPE SIZE RUNOUTS TO
FIXTURES NOT SHOWN ON PLANS.
21. COMPRESSED AIR PIPING MUST BE SLOPED TO LOW POINT DRAINS.
22. THE SINGLE POINT DEAD LOAD APPLIED TO ANY STRUCTURAL MEMBER MUST EXCEED 250 LBS.
PROVIDE TRAPEZE HANGERS TO DISTRIBUTE THE LOAD BETWEEN STRUCTURAL MEMBERS
HERE A SINGLE HANGER EXCEEDS THE LIMITATION.
23. IMMEDIATELY NOTIFY CONTRACTING OFFICER IF A CONFLICT IS IDENTIFIED. DO NOT PROCEED
WITH WORK UNTIL DIRECTED BY CONTRACTING OFFICER.
GENERAL PLUMBING NOTES
PIPING TYPE LABEL WORDING
DCW DOMESTIC COLD WATER
DHW DOMESTIC HOT WATER
PLUMBING PIPE TYPES
WCO
CLEANOUT (CO) IN RISER
PRESSURE GAUGE
FLOOR/EQUIPMENT
DRAIN AND FLOOR SINK
FLOOR OR WALL PENETRATION
VENT THRU ROOF (VTR)
RISER DIAGRAM LEGEND
FCO CLEANOUT (FCO) IN FLOOR
WATER HAMMER ARRESTOR - SPEC. TYPEWHA-A
CLEANOUT (WCO) IN WALL
N
E
DN
UP
W
S
ISOMETRIC DIRECTION ARROW
CO
EWC-1
PLUMBING FIXTURES LEGEND
ELECTRIC WATER COOLER (BI-LEVEL)
WC-1 WATER CLOSET - ACCESSIBLE -
(WALL MOUNTED) ABA
MR-1
L-1 LAVATORY, WALL MOUNTED
S-2 SINK, SINGLE BOWL, WALL MOUNTED
S-1 SINK, SINGLE BOWL, COUNTER MOUNTED
MOP RECEPTOR, CORNER
ROOM NAME
ROOM TAG
DETAIL NUMBER
SHEET WHERE DRAWN
DETAIL TAG
ROOM NAME
ROOM NUMBER
DETAIL NUMBER
SCALE
SHEET
REFERENCED
FROM
A1 A-101
SECTION TAG
SECTION NUMBER
SHEET WHERE DRAWN
GENERAL PROJECT SYMBOLS
KEYNOTE TAG
KEYNOTE NUMBER
A101 PHOTOGRAPH TAG
PHOTOGRAPH NUMBER
SHEET WHERE SHOWN
A1
PLAN
NORTH
SCALE
TRUE NORTH
A101 A1
OH
A1
DETAIL TITLE
1/8" = 1'-0" (A-101) A1
DETAIL TITLE
1/8" = 1'-0" (A-101)
SHEET
REFERENCED
FROM
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :2
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-051
P
LU
M B
IN
G
L E
G E
N D
, A B
B R
E V
IA
T
IO
N
S , A
N D
N O
T E
S
CWSCMO CMO
A
B
1 2
4" ⌀ RD-1
ROOFTOP UNIT
REFER TO MECHANICAL
EXHAUST FAN
REFER TO MECHANICAL
4"⌀ OD-1
4" ⌀ RD-1
4"⌀ OD-1
4" ⌀ RD-1
4"⌀ OD-1
4" ⌀ RD-1
4"⌀ OD-1
4" ⌀ RD-1
4"⌀ OD-1
4" ⌀ RD-1
4"⌀ OD-1
1. REFER TO DRAWING P-051 FOR PLUMBING LEGEND, ABBREVIATIONS AND
NOTES.
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :2
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-151
P
LU
M B
IN
G
P
LA
N
R O
O F
C
O P
IN
G
CWSCMO CMO
SCALE: 1/4" = 1'-0"
PLUMBING PLAN - ROOF & COPING
21 3" VTR
DRY DOCK 2
DRY DOCK 4
102101
DRY DOCK 2
DRY DOCK 3
DRY DOCK 4
PLAN
NORTH
SHEET NOTES
SHEET KEYNOTES
KEY PLAN
WET WELL 3
2' 4' 8'0'
PLAN
NORTH
1 2
WC-1
L-1
MS-1
FD-1
CONSOLE
STAIR
LOCKERS
TOILET
2"ø V
2"ø V
4"⌀ SD
FRM ABV
4"⌀ SD
FRM ABV
4"⌀ SD
FRM ABV
6" ⌀ SD DN
2"ø V
FD-1
FD-1FD-1
FD-1
FD-2
DEWATERING PUMP,
SEE MECHANICAL (TYP)
3"ø V
4"⌀ SD
FRM ABV
4"⌀ OD
FRM ABV
4"⌀ OD
4"⌀ OD
FRM ABV
4"⌀ OD
4"⌀ OD
FRM ABV
4"⌀ SD
FRM ABV
4"⌀ OD
FRM ABV
4"⌀ OD
4"⌀ OD
ODS-1
4"⌀ OD
ODS-1
4"⌀ OD
FRM ABV
4"⌀ OD
4"⌀ SD
6"⌀ SD
4"⌀ SD
4"⌀ SD
4"⌀ SD
4"⌀ SD
4"⌀ SD
FRM ABV
4"⌀ OD
FRM ABV
4"⌀ SD
1. REFER TO DRAWING P-051 FOR PLUMBING LEGEND, ABBREVIATIONS AND
NOTES.
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :3
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-152
P
LU
M B
IN
G
S A
N
IT
A R
Y P
LA
N
C
O N
T R
O L
LE
V
E L
CWSCMO CMO
SCALE: 1/4" = 1'-0"
PLUMBING SANITARY PLAN - CONTROL LEVEL
4 1 1/2" SS DOWN, 1 1/2" VENT UP.
5 2" V UP, 2" VTR.
10 4" SS DOWN.
12 2" VENT UP FROM BELOW
19 2" SS FR BEL, DISCHARGE TO FLOOR DRAIN
20 3" V UP, 3" VTR
DRY DOCK 2
DRY DOCK 4
102101
DRY DOCK 2
DRY DOCK 3
DRY DOCK 4
PLAN
NORTH
SHEET NOTES
SHEET KEYNOTES
KEY PLAN
WET WELL 3
2' 4' 8'0'
1. REFER TO DRAWING P-051 FOR PLUMBING LEGEND, ABBREVIATIONS AND
NOTES.
CO
2"⌀ FM DN
A
B
1 2
3"ø SS
2"ø SS
4"ø SS
4"ø SS
4"ø SS
2" ⌀ FM TO
CHT, SEE CIVIL
FOR CONT.
INVERT = 98.4'
4"ø SS
6" ⌀ SD FRM ABV
6" ⌀ SD, SEE
CIVIL FOR CONT.
INVERT = 98.0'
4"ø SS
92"ø V
4"ø SS
4"ø SS
4"ø SS
2"ø V
4"ø SS
4"ø SS
SP-1
6" ⌀ SD DN
6"ø SD
CO
CO
DEWATERING PUMP,
SEE MECHANICAL (TYP)
2"ø SS
SP-2
2"ø SS
SP-2 WALL SWITCH
AIR COMPRESSOR
REFER TO MECHANICAL
CO
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :3
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-153
P
LU
M B
IN
G
S A
N
IT
A R
Y P
LA
N
P
U M
P L
E V
E L
CWSCMO CMO
1 4" SS DOWN FROM ABOVE.
3 2" SS DOWN FROM ABOVE.
7 3" SS DOWN FROM ABOVE.
9 2" VENT UP
18 2" SS UP
DRY DOCK 2
DRY DOCK 4
102101
DRY DOCK 2
DRY DOCK 3
DRY DOCK 4
PLAN
NORTH
SHEET NOTES
SHEET KEYNOTES
KEY PLAN
WET WELL 3
SCALE: 1/4" = 1'-0"
PLUMBING SANITARY PLAN - PUMP LEVEL
2' 4' 8'0'
1 2
WC-1
L-1
MS-1
RPZ-1
2" ⌀ DCW
2" ⌀ DCW DN
2" ⌀ DCW UP
2"ø DCW
3/4"ø DCW
1/2"ø DCW
1/2"ø DCW
1/2"ø DHW 1/2"ø DHW
CONSOLE
LOCKERS
TOILET
MAIN
OPERATIONS
STAIR
2" ⌀ DCW FRM ABV
1 1/4" ⌀ DCW
1 1/4" ⌀ DCW
3/4" ⌀ DCW
1 1/4" ⌀ DCW
3/4" ⌀ DCW
1 1/4" ⌀ DCW
TPM-1
DWH-1
DWH-2
TPM-2
1 1/2"ø DCW
DEWATERING PUMP,
SEE MECHANICAL (TYP)
DOMESTIC WATER
SERVICE FROM PLAN
NORTH, SEE FX601
SEE MECH DETAIL A3/M-552 (TYP)
1. REFER TO DRAWING P-051 FOR PLUMBING LEGEND, ABBREVIATIONS AND
NOTES.
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :3
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-162
P
LU
M B
IN
G
S U
P P
LY
P
LA
N
C
O N
T R
O L
LE
V
E L
CWSCMO CMO
14 ELECTRONIC TRAP PRIMER MANIFOLD
15 1/2" DCW TO SERVE ELECTRONIC TRAP PRIMER MANIFOLD
16 1/2" DCW FROM ELECTRONIC TRAP PRIMER MANIFOLD
17 1/2" DCW FROM PRESSURE ACTIVATED TRAP PRIMER
SCALE: 1/4" = 1'-0"
PLUMBING SUPPLY PLAN - CONTROL LEVEL
DRY DOCK 2
DRY DOCK 4
102101
DRY DOCK 2
DRY DOCK 3
DRY DOCK 4
PLAN
NORTH
SHEET NOTES
SHEET KEYNOTES
KEY PLAN
WET WELL 3
2' 4' 8'0'
FINISHED FLOOR
OFFSET GRID DRAIN
TO BACK TO FIXTURE
INSTALL P-TRAP
PARALLEL WITH WALL
COORDINATE WASTE
TO WALL ROUGH-IN
WITH WATER PIPE
INSULATION KIT REQUIRED
INSTANTANEOUS
WATER HEATER (DWH-1)
DCW SUPPLY
DRAIN RUN FULL SIZE TO
TO SLAB FLOOR DRAIN
FINISHED FLOOR
REDUCED PRESSURE
BACKFLOW PREVENTOR
WATER
METER
SHUT-OFF
VALVE
FROM WATER
SERVICE, SEE
FX102 FOR CONT.
TO BUILDING
12" MIN.
SUPPORT
STAND (TYP)
ANCHOR TO FLR (TYP)
FLOOR DRAIN
BFP
BACKFLOW PREVENTER (BFP-2)
STRAINER
BALL VALVE
SEE MECHANICAL SHEETS
FOR CONTINUATION
DOMESTIC COLD
WATER SUPPLY
2"
M
IN
12"
APPROX
TURN FLASHING
DOWN INSIDE PIPE
MIN. 3"
BUILT-UP
ROOFING
G.E. SILICONE
CAULK BED FULL
PERIMETER UNDER
FLASHING
MIN. 1/8"
THICK LEAD OR
COPPER FLASHING.
ALL JOINTS BRAZED
OR SOLDERED.
ROOF
INSULATION
1/2" STEEL PLATE
CONCRETE ROOF
ROOF SLEEVE
VENT PIPE
MAXIMUM 1" SPACE
BETWEEN TOP OF PIPE
AND TOP OF FLASHING
NOTE:
B
C
D 1-1/4"
3/4"
1"
61-113
12-32
33-60
SHOWER
SINK
JANITOR'S SINK
LAVATORY
1 1
A
SIZE
SINGLE FIXTURE
PDI
PDI SIZE "A"
1/2"
SIZE
PIPE
5-11
UNIT LOAD
FIXTURE
STANDARDS AND
INSTALL PER PDI
INSTRUCTIONS
MANUFACTURER'S
HOT OR COLD WATER SUPPLY
VALVE WATER CLOSET
MULTIPLE FIXTURES
FIXTURE UNIT TABULATION
IF HORIZONTAL BRANCH IS
LESS THAN 20' LONG, PROVIDE
ONE WHA AT END OF LINE. IF
BRANCH IS GREATER THAN 20'
LONG, PROVIDE ANOTHER
WHA IN MIDDLE, EACH SIZED
FOR HALF THE FIXTURE UNITS.
FIXTURE
COLD
HOT
URINAL 4 --
1.5 1.5
3 3
ALL SIZES PER PDI-WH-201
PROVIDE ASSE 1010 CERTIFIED WATER HAMMER ARRESTERS. INSTALL IN HORIZONTAL OR
VERTICAL POSITION, BUT NEVER UPSIDE DOWN. INSTALL IN LINE WITH WATER FLOW DIRECTION IF
POSSIBLE. SIZE THE UNITS PER THE TABLES SHOWN.
AA 1/2" 1-4
FLOOR
1/2"1/2" 1/2"
DCW SUPPLY LINE
SEE PLANS FOR SIZE
3/4"
ELECTRONIC TRAP PRIMER MANIFOLD
DISTRIBUTION UNIT, TYPICAL. SEE PLANS
FOR QUANTITY OF FD SERVED PER UNIT
TRANSITION TO TYPE
K COPPER, TYPICAL.
1/2" TRAP PRIMER
LINE TO FD, TYPICAL.
CHECK VALVE
FIBERGLASS BASIN
SOLID STEEL GAS
TIGHT COVER
GATE VALVE
FOR CONTINUATION
SEE FLOOR PLANS
VENT POWER SUPPLY,
SEE ELEC PLANS
HIGH WATER
ALARM BELL
CONTROL PANEL
FINISHED FLOOR
FOR CONTINUATION
SEE FLOOR PLANS
INLET
QUICK DISCONNECT
SUBMERSIBLE
GRINDER PUMP SP-1 13" - OFF FLOAT
27" - ON FLOAT
33" - ALARM FLOAT
CHECK VALVE
FOR CONT OF PIPING SEE
PLUMBING SHEETS
UNION
SUMP PUMP SP-2
SUMP PIT. SEE
STRUCTURAL
WALL SWITCH
PUMP LEVEL
TO DUPLEX ELECTRICAL
OUTLET - SEE ELEC DWGS
FOR CONT
2" SUMP PUMP DISCHARGE
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :3
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-551
P
LU
M B
IN
G
D E
T A
IL
S
CWSCMO CMO
NOT TO SCALE
B1
TANKLESS WATER HEATER FOR WALL HUNG LAVATORY
NOT TO SCALE
A3
BACKFLOW PREVENTOR DETAIL
NOT TO SCALE
C1
MECHANICAL MAKE-UP WATER DETAIL
NOT TO SCALE
D1
VENT THRU ROOF DETAIL
NOT TO SCALE
A4
WATER HAMMER ARRESTOR DETAIL
NOT TO SCALE
A1
ELECTRONIC TRAP PRIMER DETAIL
NOT TO SCALE
C3
GRINDER PUMP SP-1 DETAIL
NOT TO SCALE
C4
SUMP PUMP SP-2 DETAIL
PIPING SCHEDULE
PIPING SYSTEM DISCIPLINE
DESIGNATION
PIPING MATERIAL NOTES
SANITARY 22 00 00
STORM DRAINAGE
VENT
DOMESTIC WATER
CAST IRON
COPPER
22 00 00
22 00 00
22 00 00
SANITARY (EXTERIOR) 316L STAINLESS STEEL
CAST IRON
CAST IRON
22 00 00
EXTERIOR TO BLDG
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :3
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-651
P
LU
M B
IN
G
S C
H E
D U
LE
S
CWSCMO CMO
PLUMBING FIXTURE SCHEDULE
MARK DESCRIPTION
CONNECTIONS
COLD WATER HOT WATER VENT WASTE
GPM GPF REMARKS
WC-1 WATER CLOSET 1" - 2" 4" - 1.28 FLOOR MOUNTED, MANUAL FLUSH VALVE
L-1 LAVATORY, WALL HUNG 1/2" 2" 0.5 - PROVIDE TRIM ONLY, MANUAL FAUCET, NOTE 31/2" 1 1/2"
MOUNTING HEIGHT
(LOWEST FLOOD RIM)
15"
34"
NOTES:
1. ALL FIXTURES INDICATED AS ARCHITECTURAL BARRIERS ACT (ABA) SHALL COMPLY AND BE INSTALLED IN ACCORDANCE WITH THE LATEST EDITION OF THE USFAS AND CABO/ANSI A117.1.
2. PROVIDE AN EPA WATERSENSE CERTIFIED AND LABELED FIXTURE.
3. PROVIDE WITH ASSE 1070 MIXING VALVE.
MS-1 SINK, SINGLE BOWL UTILITY 1/2" 1/2" 3" 1.5 - FLOOR MOUNTED, MOLDED STONE1 1/2" 34"
MARK DESCRIPTION LOCATION
VOLTS
ELECTRICAL DATA
REMARKS
DOMESTIC WATER HEATER SCHEDULE (DWH)
DWH-1 POINT OF USE 208 0.3 110101
PHASE
AMPS
KW
13.3
TURN ON
(GPM)
TEMP SETTING
(°F)
DWH-2 POINT OF USE 208 0.2 85115 1 20 4.1
RPZ-1 3" 42 10
MARK SIZE MATERIAL FLOW (GPM) PRESSURE DROP
(GPM)
REMARKS
BACKFLOW PREVENTER SCHEDULE
LOCATION
(ROOM / #)
CONTROL LEVELBRONZE BODY
MARK DRAIN TYPE
FD-1
DRAIN SIZE
4"
TRAP PRIMER
CONNECTION
6" ROUND YESFLOOR DRAIN - HEAVY DUTY
REMARKSSTRAINER
ELECTRONIC TRAP PRIMER MANIFOLD
DRAIN AND CLEAN OUT SCHEDULE
MARK DESCRIPTION
TPM-1 ELECTRONIC TRAP PRIMER MANIFOLD 3/4" 1 101
REMARKS
TRAP PRIMER MANIFOLD SCHEDULE (TPM)
COLD WATER
LINE SIZE
NUMBER OF
DRAINS SERVING
LOCATION
(BLDG / ROOM)
VOLTAGE
MARK PUMP DESCRIPTION
SP-1 SEWAGE PUMP
TYPE
GRINDER
TOTAL HEAD
(FT WC)
50 27
PUMP SCHEDULE
CAPACITY
(GPM)
MIN. MOTOR
(HP)
VOLTAGE /
PHASE
480/3
REMARKS
PUMP LEVEL
LOCATION
(ROOM / #)
SP-2 SUMP PUMP SUMP 15 22 1 208/1 PUMP LEVEL
TPM-2 ELECTRONIC TRAP PRIMER MANIFOLD 3/4" 4 115 24
CO CLEAN OUT FULL SIZE ROUND - -
RD-1 ROOF DRAIN - PRIMARY DOME - -4"
FD-2 3" 6" ROUND YESFLOOR DRAIN - HEAVY DUTY PRESSURE ACTUATED TRAP PRIMER VALVE
MANUAL SWITCH
BASIN TANK 36"Dx48"H
OD-1 OVERFLOW ROOF DRAIN DOME -4"
ODS-1 OVERFLOW DRAIN SPOUT - -4" -
WC-1
DWH-2
DWH-1
L-1
TPM-1
RPZ-1
1/2"ø DCW
2"ø DCW
2"ø DCW
3/4"ø DCW
1 1/2"ø DCW
1 1/4"ø DCW
1"ø DCW
3/4"ø DCW
3/4"ø DCW
1/2"ø DCW
1/2"ø DCW
TPM-2
1/2"ø DCW
1/2"ø DCW
3/4"ø DCW
3/4"ø DCW
3/4"ø DCW
SEE FX102
FOR CONT.
1 1/4"ø DCW
1. REFER TO DRAWING P-051 FOR PLUMBING LEGEND, ABBREVIATIONS AND
NOTES.
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :3
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-851
P
LU
M B
IN
G
S U
P P
LY
R
IS
E
R D
IA
G
R A
M
CWSCMO CMO
NOT TO SCALE
WATER RISER DIAGRAM
SHEET NOTES
2"ø V
2" VTR
FD-1
CO4"ø SS
CO
SP-2
4"ø SS
4"ø SS
2" ⌀ FM
FD-1
4"ø SS
FD-1
CO
2"ø V
WC-1
4"ø SS
FD-2
L-1
2"ø SS
1 1/2"ø SS
SP-1
4"ø SS
2" ⌀ FM
FD-1
FD-1
2"ø V
CO
4"ø SS
2"ø V
MS-1
DISCHARGE TO FD
3" VTR
2"ø V
2"ø V
2"ø V
2"ø V 3"ø V
1. REFER TO DRAWING P-051 FOR PLUMBING LEGEND, ABBREVIATIONS AND
NOTES.
RD-1
RD-1
RD-1
6"ø SD
6" SD, SEE
CIVIL DWG CS113
OD-1
OD-1
OD-1
OD-1
RD-1
RD-1
OD-1
RD-1
OD-1
ODS-1
ODS-1
4"ø SD
4"⌀ OD
4"⌀ OD
4"⌀ OD
4"⌀ OD
4"⌀ OD
4"⌀ OD
4"ø SD
6"ø SD
4"ø SD
4"ø SD
4"ø SD
N O
T F
O R
C O
N S
T R
U C
T
IO
N
P R
E L
IM
IN
A
R Y
SATISFACTORY TO
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V F
A C
A T
LA
N
T
IC
AS NOTED
P O
R T
S M
O U
T H
V
IR
G
IN
IA
N O
R F
O L K
N A
V A
L S
H
IP
Y A
R D
D R
Y D
O C
K
R E
P A
IR
A
N D
M O
D E
R N
IZ
A
TI
O
N
1715740
A P
P R
D A
T E
D E
S C
R
IP
T
IO
N S
Y M
UNCLASSIFIED
UNCLASSIFIED
U N
C
LA
S S
IF
IE
D
P
LO
T T
E D
F
IL
E
N A
M E
DRAWING SCALES SHOWN BASED ON 34" x 22" DRAWINGPRE-FINAL - 2023/10/26
XXX
XXX
XXX
LA
FA
Y E
T
TE
R
IV
E R
A N
N E
X
N O
R
FO
LK
, V
A
DATE
/2
/2
:0 :3
A
M C
R e v it P ro je c ts
\D R
Y D
-1
-M
-N P
W c m o v e rf e lt .r v t
P-852
P
LU
M B
IN
G
S A
N
IT
A R
Y A
N D
S T
O R
M R
IS
E
R D
IA
G
R A
M
CWSCMO CMO
NOT TO SCALE
SANITARY RISER DIAGRAM
SHEET NOTES
NOT TO SCALE
STORM RISER DIAGRAM
File details come from the government source that posted it. Updated .