Culvert Inspection Report CO FTNP ROMO 407(1).pdf
PDF 3 MB Posted
- Attached to
- CO NP ROMO 407(1) Holzwarth Culvert
- Solicitation number
- 6982AF27B000004
About this file
This is a Culvert Inspection Report for the Holzwarth Culvert, a six-barrel corrugated metal pipe structure located on the Holzwarth Access Road over the Colorado River in Rocky Mountain National Park, Colorado. The routine inspection was conducted on October 1, 2024, by the Federal Highway Administration's FLH Office of Bridges and Structures Bridge Inspection Program.
The culvert is in poor structural condition and rated Priority B (Major), requiring replacement within five years. Critical findings include severe corrosion of barrel inverts with rust holes and missing sections, widespread barrel distortions from invert section loss, delaminating and spalling of concrete headwalls with exposed rebar, undermining of barrels at downstream ends (up to 2.5 feet in some locations), and water piping around most barrels. The structure was overtopped during spring 2022 high water events. The upstream channel shows poor alignment and eastward migration, with sediment accumulation reducing flow through the westernmost barrel. Load ratings have been reduced 50 percent due to barrel deterioration, with inventory capacity of 29 tons and operating capacity of 38 tons. The inspection team recommended structure replacement in the near future due to poor invert conditions, loss of soil support from undermining, concerns about long-term stability during high-flow events, and inadequate barrel capacity. The preliminary reconstruction cost estimate is $500,000, including mobilization, traffic control, and design/construction engineering. The structure was built in 1982 and is classified as an NPS Administrative Road with an average daily traffic count of 2.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CULVERT INSPECTION REPORT
HOLZWARTH CULVERT
HOLZWARTH ACCESS ROAD OVER COLORADO RIVER
ROCKY MOUNTAIN NATIONAL PARK
LOOKING WEST
STRUCTURE NO. 1520-029S
INSPECTION TYPE: ROUTINE
INSPECTION DATE: 10/1/2024
SOUTH (DOWNSTREAM) SIDE
Report prepared by:
Federal Highway Administration FLH Office of Bridges and Structures Bridge Inspection Program 22001 Loudoun County Parkway, Building E2, Suite 200 Ashburn, VA 20147 https://bridge.flhd.fhwa.dot.gov https://bridge.flhd.fhwa.dot.gov
STRUCTURE SUMMARY STRUCTURE NO. 1520-029S
HOLZWARTH CULVERT INSPECTION DATE: 10/01/2024
CULVERT IDENTIFICATION AND DESCRIPTION
MAIN SPAN MATERIAL: ..... 3 - STEEL NO. OF BARRELS:
FOUNDATION: .................... 6 - N/A BARREL LENGTH: ............. 12.2 FT (3.72 M)
STRUCT. TOTAL LENGTH: 38.7 FT (11.8 M) SKEW ANGLE: ................... 0 °
MAX. SPAN LENGTH: ........ 6 FT (1.8 M) YEAR BUILT:
PROJ./PLAN REF. NO: ....... YEAR RECONSTRUCTED:
NPS ROAD CLASS: ............ 5 - ADMINISTRATIVE
STRUCTURE HISTORY:
LOCATION
ROCKY MOUNTAIN NATIONAL PARK MILE POINT: .. .00 (KM PT 0)
STATE: ................................ 088 - COLORADO LOCATION: .... West side of park, approximately 1 mile south of Timber Creek Campground.FACILITY CARRIED: .......... HOLZWARTH ACCESS ROAD Beyond locked gate.
FEATURE INTERSECTED: COLORADO RIVER
INSPECTION TEAM: D. Christensen, B. Dietrick, P. Sharifi
CONDITION ASSESSMENT:
Bill Dietrick
REPORT REVIEW:
Marcus Miller
REPORT APPROVAL: Date: 01/30/2025
Jorgomai Ceesay
STRUCTURE EVALUATION SUMMARY
This six-barrel corrugated metal pipe culvert is in poor structural condition. Inspection findings include delaminating, spalling, and cracking of the headwalls; spalling and undermining of concrete at the bottom of both the upstream and downstream divider walls between barrels; severe corroding of the barrel inverts, with rust holes present; missing sections of barrel inverts, and torn and uplifted inverts at the upstream end of the barrels due to high flow impacts and corrosion; widespread barrel distortions resulting from invert section loss;
undermining of barrels at the downstream end; and minor debris accumulation at the upstream divider walls and inside several barrels. In addition, previous inspection teams observed water piping around most of the barrels, particularly during highwater events.
In view of the poor condition of the culvert inverts and the loss of soil support due to undermining, there are concerns about the long-term stability of the structure, particularly during highwater events. A local informed the inspection team that the structure was overtopped in the spring of 2022. The upstream channel has poor alignment and is migrating to the east. Given the high cost of repairs and the evident lack of capacity of the barrels for high flow conditions, it is recommended that the structure be replaced in the near future.
RECOMMENDATIONS AND ESTIMATED COSTS STRUCTURE NO. 1520-029S
HOLZWARTH CULVERT INSPECTION DATE : 10/01/2024
PRIORITY OF IMPROVEMENT226
A (Critical) - Structure is closed, in immediate damage of collapse, or presents a critical safety danger.
B (Major) - Structure is seriously deficient or presents a safety hazard, but can remain open at reduced loads or with frequent inspections.
C (Moderate) - Structure is deficient, functionally obsolete, or requires substantial repairs to prevent a serious deficiency or unsafe condition.
D (Minor) - Structure is generally in good condition. Preventive maintenance may be required.
E (Special) - Structure is under construction or reconstruction.
B
Item No.
Maintenance Recommendations
(GENERALLY NOT FLHP ELIGIBLE)
QTY. UNIT UNIT
COST
PRELIM.
COST
ESTIMATE
PRELIM. MAINTENANCE TOTAL :
Item No.
REHABILITATION/RECONSTRUCTION
(TYPICALLY NEEDED WITHIN 5 YEARS)
QTY. UNIT
UNIT
COST
PRELIM. COST ESTIMATES
REHAB RECONSTR
62 REPLACE STRUCTURE.
1 LS 500000 500000
PRELIM. REHABILITATION/RECONSTRUCTION TOTAL : 500000
COST ESTIMATE SUMMARY
PRELIM. MAINTENANCE TOTAL :
PRELIM. REHABILITATION TOTAL :
PRELIM. RECONSTRUCTION TOTAL : .. 500000
TOTAL ITEMIZED COSTS:
PRELIMINARY ESTIMATE TOTAL * :
(*Includes typical contract costs for mobilization, traffic control and design/construction engineering: but does not include detour bridges, work beyond the bridge limits, or work not listed above. Estimates are approximate and are for planning purposes only; they should not be used as a complete or final engineers estimate.)
Remarks : Cost estimates are based on historical data, including costs for similar projects when available.
FIELD INSPECTION REPORT STRUCTURE NO. 1520-029S
CONDITION RATING CODES FOR ITEMS 58 - 62, 222, 223
N NOT APPLICABLE 3 SERIOUS CONDITION - loss of section, deterioration, spalling, or scour have seriously affected primary structural components. Local failures are possible. Fatigue cracks in steel or 9 EXCELLENT CONDITION shear cracks in concrete may be present.
8 VERY GOOD CONDITION - no problems noted. 2 CRITICAL CONDITION - advanced deterioration of primary structural elements. Fatigue cracks in steel or shear cracks in concrete may be present or scour may have removed
7 GOOD CONDITION - some minor problems. substructure support. Unless closely monitored it may be necessary to close the structure until corrective action can be taken.
6 SATISFACTORY CONDITION - structural elements show some minor deterioration.
1 “IMMINENT” FAILURE CONDITION - major deterioration or section loss present in critical
5 FAIR CONDITION - all primary structural elements are sound but may have minor structural components or obvious vertical or horizontal movement affecting structure stability.
section loss, cracking, spalling, or scour. Structure is closed to
4 POOR CONDITION - advanced section loss, deterioration, spalling, or scour. 0 FAILED CONDITION - out of service; beyond corrective action.
CONDITION RATING CODE EQUIVALENTS FOR SUB-ELEMENTS
G = GOOD (CODES 7 - 9) F = FAIR (CODES 5 - 6) P = POOR (CODES 0 - 4)
61. CHANNEL 4 222. APPROACHES 6
1. ALIGNMENT: P 1. APPROACH SLABS: N
2. EROSION AND/OR SCOUR: F 2. RELIEF JOINTS: N
3. CHANNEL PROTECTION: F 3. APPROACH GUARDRAIL: N
4. WATERWAY OBSTRUCTIONS: F 4. SURFACING: F
5. OTHER: N 5. EROSION: G
6. ADEQUACY OF OPENING: 2 - INSUFF 6. SETTLEMENT: G
7. NORMAL VELOCITY: 2 - MED 7. SIGNS: N
8. AVERAGE CLEAR OPENING: 3 FT 8. ALIGNMENT: G
9. STREAM BED COMPOSITION: 9. OTHER: N
GRAVEL 223. RETAINING WALL N
62. CULVERT 3
1. BARREL(S): P
2. FOOTINGS: N
3. HEADWALLS: P
4. WINGWALLS: P
5. DEBRIS AND/OR SLIT: F
6. EROSION AND/OR SCOUR: F
7. SETTLEMENT AND/OR DEFLECTION: F
8. ADEQUACY OF COVER: G
9. PARAPETS AND/OR RAILINGS: N
10. ROADWAY SURFACE: F
11. RIDEABILITY: G
12. OTHER: FLOW DIVERSION STRUC F
1. WALL:
2. WEEP HOLES:
3. FOUNDATION:
4. EROSION AND/OR SCOUR:
5. SETTLEMENT OR DEFLECTION:
6. OTHER
36. TRAFFIC AND SAFETY FEATURES
A. BRIDGE RAILINGS: N
B. TRANSITIONS: N
C. APPROACH GUARDRAILS: 0
D. APPROACH GUARDRAIL ENDS: 0
TRAFFIC SAFETY RATING CODES
0 - Does not meet standards or a safety features is required and none is provided.
1 - Meets currently acceptable standards.
N - Not applicable or a safety features is not required.
(cont'd)FIELD INSPECTION REPORT - CULVERT STRUCTURE NO. 1520-029S
ITEM REFERENCE AND REMARKS
61.1
61.4
UPSTREAM CHANNEL ALIGNMENT DURING HIGH FLOWS IS TOWARD NORTHEAST BANK WITH VISIBLE SIGNS OF CUTTING.
SEDIMENT ACCUMULATION IN CENTER OF UPSTREAM CHANNEL; WATER FLOWS AROUND SEDIMENT AND THROUGH ALL BARRELS. MINIMAL FLOW THROUGH WEST BARREL DUE TO SEDIMENT DEPOSIT AT UPSTREAM END AND THROUGHOUT INVERT N WEST BARREL #6. CURVE IN DOWNSTREAM CHANNEL, APPROXIMATELY 100' FROM STRUCTURE.
61.2 SEE BRIDGE FILE FOR SCOUR EVALUATION.
61.2
61.3
222.5
RIPRAP ALONG NORTHEAST UPSTREAM CHANNEL BANK AND NORTHEAST WINGWALL TO COUNTERACT PAST EROSION;
CONCRETE REPAIRS TO NORTHEAST WINGWALL EMBANKMENT AND ADJACENT ROADWAY EMBANKMENT. CHANNEL BANK EROSION CONTINUES BEYOND LIMITS OF RIPRAP AT EAST UPSTREAM BANK AND ALONG WEST UPSTREAM BANK.
MINOR VERTICAL CUTTING OF EAST DOWNSTREAM CHANNEL BANK.
61.6 PARK PERSONNEL INFORMED 2010 INSPECTION TEAM THAT MEADOW ADJACENT TO STRUCTURE ROUTINELY FLOODS. A LOCAL
INFORMED US THAT THIS STRUCTURE OVERTOPPED IN SPRING OF 2022.
62.1 PERFORATIONS FROM PIN HOLE SIZE TO 2" DIAMETER IS TYPICALLLY FOUND THROUGHOUT INVERTS OF ALL BARRELS.
MISSING LARGE PORTIONS OF INVERT DUE TO CORROSION AT UPSTREAM END OF BARREL #5. TORN CORRUGATIONS AT
UPSTREAM END OF MOST BARRELS WITH SEVERAL ENDS FOLDING IN ON THEMSELVES.
MINOR DISTORTING OF BARREL #3 AT UPSTREAM END.
4' OF CANTILEVER AT DOWNSTREAM END OF EAST BARREL #1. 12" OF PENETRATION AND UNDERMINING BENEATH BARREL #3
AT DOWNSTREAM END AND 2.5' BENEATH BARREL #4 AT DOWNSTREAM.
62.3 SEVERE SPALLING, UP TO 1.4' DEEP AT BOTTOM OF HEADWALLS BETWEEN BARRELS, ESPECIALLY AT DOWNSTREAM END. 3/4" AND 1.5" GAP BETWEEN EAST END OF UPSTREAM HEADWALL AND NORTHEAST WINGWALL. MINOR EROSION AT EAST END OF
BOTH HEADWALLS.
MINOR VERTICAL CRACKING OF HEADWALLS, A FEW WITH EFFLORESCENCE. MINOR GOUGES AND SCRAPES THROUGHOUT UPSTREAM HEADWALL DUE TO HIGHWATER DEBRIS IMPACT. MODERATE SPALLING, UP TO 2-1/2" DEEP ALONG TOP CORNERS OF BOTH HEADWALLS. WIDESPREAD DELAMINATING OF CONCRETE ALONG TOPS OF HEADWALLS. SEVERAL CONCRETE PATCHES IN SOUTH HEADWALL ABOVE BARRELS. WIDE CRACKS AND LARGE SPALL WITH EXPOSED REBAR IN DOWNSTREAM
HEADWALL NEAR BARREL #6.
62.4 TOP 18" OF NORTHWEST WINGWALL BROKEN AND SEPARATED FROM LOWER PORTION BY APPROXIMATELY 4" WITH SEVERAL STONES MISSING. SEPARATION/VERTICAL JOINTS BETWEEN NORTHWEST AND NORTHEAST WINGWALLS AND UPSTREAM HEADWALL; CRACKED AREAS SEALED WITH GROUT. UP TO 12" OF UNDERCUTTING/VOIDS AT NORTHEAST WINGWALL NEAR
HEADWALL.
62.5 MINOR DEBRIS CAUGHT ON A FEW UPSTREAM DIVIDER WALLS AND ON A FEW INVERTS. 8" TO 9" AVERAGE SEDIMENT BUILD UP
ON BARREL #6 INVERT.
62.6 PIPING OF WATER SUSPECTED BENEATH ALL BARRELS. UNDERMINING OF BARREL ENDS, TYPICALLY UP TO 12" BEHIND CORNERS OF BARRELS WITH UP TO 20" AT DOWNSTREAM END OF BARREL #1. EAST BARREL CANTILEVERS OUT 4' FROM DOWNSTREAM HEADWALL AND IS COMPLETELY UNDERMINED AT CANTILEVERED PORTION. 12" TO 2.5' DROP IN CHANNEL
BOTTOM AT OUTLET ENDS OF BARRELS #1 THROUGH #3.
EROSION BEHIND NORTHWEST WINGWALL.
62.12
222.4
STREAM FLOW DIVERSION STRUCTURE AT DOWNSTREAM END OF WEST BARREL #6; 8" HIGH AND 20" OF UNDERMINING BENEATH DIVERSION CONTROL STRUCTURE HEADWALL. 1" WIDE CRACK IN DIVERSION HEADWALL ABOVE BARREL.
36.C
36.D
222.3
NO APPROACH RAIL SYSTEM PRESENT AT STRUCTURE SITE.
STRUCTURE LOAD RATING STRUCTURE NO. 1520-029S
TRUCK TYPE
INVENTORY RATING (NORMAL TRAFFIC) OPERATING RATING (MAXIMUM LOAD)
TONS METRIC TONS TONS METRIC TONS
H 16 15 21 19
HS 29 26 38 34
TYPE 3 34 31 42 38
TYPE 3S2 49 44 60 54
TYPE 3-3 57 52 67 61
DESIGN LOADING: 0 - UNKNOWN
CAPACITY MEETS OR EXCEEDS DESIGN LOAD
CAPACITY IS LESS THAN DESIGN LOAD
ORIGINAL LOAD RATING CALCULATION APPLICABLE
X ORIGINAL LOAD RATING CALCULATION REVISED
DATE OF LOAD RATING CALCULATION: 07/27/2016
LOAD RATING CONTROLLED BY: SEAM STRENGTH
REMARKS: SEE STRUCTURE FILE FOR LOAD RATING CALCULATIONS. RATING INCLUDES 50% REDUCTION DUE TO DETERIORATION OF BARRELS.
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 1520-029S
STRUCTURE IDENTIFICATION
(201) PARK: ROCKY MOUNTAIN NATIONAL PARK
(202) STRUCTURE NAME:..............HOLZWARTH CULVERT
(203) STRUCTURE KIND:............... 2 - CULVERT
(204) STRUCTURE NUMBER:.........1520-029 S
1 - INTERMOUNTAIN(205) NPS REGION:
(206) ROUTE CODE NUMBER:
(207) ROAD SECTION NO:
(208) NPS ROAD CLASS:............... 5 - ADMINISTRATIVE
(209) WITHIN NPS BNDRY?:.......... Yes
(210) OPERATING UNIT:.................PARK
(211) PROJECT NO(S):
(212) DRAWING NUMBERS:
(21) MAINTAINED BY:......................66 - NATIONAL PARK SERVICE
(22) OWNER:................................... 66 - NATIONAL PARK SERVICE
(1) STATE:............................................ 088 - COLORADO
(2) STATE HWY. AGENCY DIST:
(3) COUNTY CODE:
(4) CITY / PLACE CODE:
(5) INVENTORY ROUTE:
(6) FEATURES INTERSECTED:
(7) FACILITY CARRIED:
(8) STATE STRUCTURE NO:
(9) LOCATION:
(10) INV. RTE. - MIN. VERT. CLR:
(11) MILE POINT:
(27) YEAR BUILT:
(106) YEAR RECONSTRUCTED:
(20) TOLL:
(37) HISTORIC DESIGNATION:
08049 GRAND
00000
1 6 8 00000 0
COLORADO RIVER
HOLZWARTH ACCESS ROAD
1520029S0000000
West side of park, approximately 1 mile south of Timber Creek Campground.
Beyond locked gate.
99.99 FT ( 99.99 M)
.00 (KM PT: 0 )
3 - ON FREE ROAD
5 - NOT ELIGIBLE
STRUCTURE DESCRIPTION, FOUNDATION, AND DECK TYPE
(43A) MAIN STR. MATERIAL:..........3 - STEEL (44A) APPR. STR. MATERIAL:............ 0 - Other
(43B) MAIN STR. TYPE:.................. 19 - CULVERT (INCLUDES FRAME (44B) APPR. STR. TYPE:.................... 00 - OTHER
CULVERTS)
(45) NO. OF MAIN SPANS:..............006 (46) NO OF APPROACH SPANS:
(48) MAX. SPAN LENGTH:..............6 FT ( 1.8 M)
(49) STRUCTURE LENGTH:........... 38.7 FT ( 11.8 M) (108) WEAR SURFACE/PROTECT SYSTEM:
(216A) ABUTMENT #1 FDN:........... 6 - N/A A) TYPE WEARING SURFACE:.. N - NA
(216B) ABUTMENT #2 FDN:........... 6 - N/A B) TYPE MEMBRANE:................. N - NA
(217A) PREDOM. PIER FDN:.......... 6 - N/A C) TYPE PROTECTION:.............. N - NA
(217B) SECOND. PIER FDN:.......... 6 - N/A (218) IS SALT USED?.......................... NO
(107) DECK TYPE:.......................... N - NOT APPLICABLE
LOAD RATING AND POSTING
(31) DESIGN LOAD:.........................0 - UNKNOWN (41) LOAD RESTRICTION:.................. A - OPEN
(66) INVENTORY RATING:..............29 METRIC TONS) (70) BRIDGE POSTING:...................... 5 - EQUAL TO OR ABOVE LEGALTONS ( 26.3
LOADS
(64) OPERATING RATING:..............38 TONS ( 34.5 METRIC TONS)
INSPECTION DATES
(90) INSPECTION DATE: 10/01/2024 (91) FREQ. OF INSP: 12 MONTHS (92 / 93) CRITICAL FEATURE INSPECTION (CFI):
(219) ADD. STUDIES NEEDED: N - 0 - NONE (A) FRACTURE CRITICAL:.......... N
(220) SPECIAL STUDY TYPE: 0 - NONE INSP. EVERY MONTHS - LAST INSP:
(221) SPECIAL STUDY DATE: (B) UNDERWATER:..................... N
INSP. EVERY MONTHS - LAST INSP:
(C) SPECIAL INSPECTION:........ N
INSP. EVERY MONTHS - LAST INSP:
STRUCTURE INVENTORY AND APPRAISAL STRUCTURE NO. 1520-029S
GEOMETRY, TRAFFIC, AND NAVIGATIONAL DATA
(16) LATITUDE:................................ 40° 22'17.76" N (51) CURB TO CURB WIDTH:............ 8.2 FT ( 2.5 M)
(17) LONGITUDE:............................105 51° '32.34" W (52) DECK WIDTH:.......................... 0.0 FT ( 0 M)
(19) DETOUR LENGTH:.................. 99 MI ( 159 KM) (32) APPR. ROADWAY WIDTH:...... 12.0 FT ( 3.7 M)
(28A) LANES ON STRUCT:.............01 (213) APPR. PAVEMENT WIDTH:... 0.0 FT ( 0 M)
(28B) LANES UNDER STRUCT:......00 LEFT SHOULDER:............... 0.0 FT ( 0 M)
(42A) SERVICE ON:.........................1 - HIGHWAY RIGHT SHOULDER:.......... 0.0 FT ( 0 M)
(42B) SERVICE UNDER:................. 5 - WATERWAY (33) BRIDGE MEDIAN:.................... 0 - NO MEDIAN
(29) AVG DAILY TRAFFIC:..............2 (34) SKEW ANGLE:......................... 0 °
(30) YEAR OF ADT:......................... 2019 (35) STRUCTURE FLARED:............ 0 - NO FLARE
(114) FUTURE ADT:.........................2 (47) TOTAL HORIZ. CLEARANCE:.. 12.2 FT ( 3.7 M)
(115) YEAR OF FUTURE ADT:........2039 (50) CURB OR SIDEWALK WIDTHS:
(101) PARALLEL STRUCTURE:......N - NO PARALLEL STRUCTURE LEFT:.................................... 0.0 FT ( 0 M)
(38) NAVIGATION CONTROL:.........N RIGHT:.................................. 0.0 FT ( 0 M)
(39) VERTICAL CLEARANCE:.........0 FT ( 0 M) (214) BRIDGE RAIL TYPE
(40) HORIZ. CLEARANCE:..............0 FT ( 0 M) RAIL CONFIGURATION:...... 0 - N/A
(111) ABUT OR PIER PROT:........... MATERIAL:........................... 0 - N/A
LATERAL UNDERCLEARANCE: DESIGN TYPE:..................... 0 - N/A
(55) RIGHT:...............................00 FT ( 0 M) (215) BRIDGE RAIL HEIGHT:.......... .00 FT ( 0 M)
(56) LEFT:.................................0 FT ( 0 M) (53) MIN. VRT. CLR. OVER DECK: 99.99 FT ( 99.99 M)
(54) MIN. VRT. UNDRCLRANCE:... .00 FT ( 0 M)
CONDITION AND APPRAISAL DATA, PROPOSED IMPROVEMENTS, AND COST
(58) DECK:....................................... N
(59) SUPERSTRUCTURE:...............N
(60) SUBSTRUCTURE:.......... N
(61) CHANNEL:
(62) CULVERT:
(222) APPROACHES:
(223) RETAINING WALL:.................N
(36) TRAFFIC SAFETY FEAT: N N 0 0
(75A) TYPE OF WORK:................... 31 - REPLACEMENT - LOAD/GEOMETRY
(75B) WORK DONE BY:.................. 1 - WORK TO BE DONE BY CONTRACT
(76) IMPROVEMENT LENGTH:.......38.7 FT ( 11.8 M)
(67) STRUCTURAL EVALUATION:
(68) DECK GEOMETRY:
(69) UNDERCLEARANCES:................ N
(71) WATERWAY ADEQUACY:
(72) APPROACH ALIGNMENT:
(113) SCOUR CRITICAL:.................... 4 - ACTION IS REQUIRED TO
PROTECT EXPOSED FOUNDATIONS
(225) PURPOSE OF IMPROVEMENT: 3 - CONSTRUCTION
(226) PRIORITY OF IMPROVEMENT: B - MAJOR
(227) MAINTENANCE COST:.............$ 0
(228) REHAB / RECNSTR COST:..... $ 0
(229) CONSTRUCTION COST:.......... $ 500000
ADDITIONAL INFORMATION
(230) STRUCTURE HISTORY:
(231) ADDITIONAL CONSIDERATIONS:
(330) ADDITIONAL CONFIGURATION INFORMATION:
https://LENGTH:
Inspector: Dietrick,Bill Structure Number: 1520029S0000000 Inspection Date: 10/01/2024 Facility Carried: HOLZWARTH ACCESS R
Environment Total Quantity Units Condition
State 1 Condition
State 2 Condition
State 3 Condition
State 4
240-Steel Culvert 1 - Ben. 73 ft. 0 0 0 73
1000-Corrosion 63 0 0 0 63
6000-Scour 10 0 0 0 10
Inspector: Bill Dietrick Structure Number: 1520029S0000000
Inspection Date: 10/01/2024 Facility Carried: HOLZWARTH ACCESS
Culvert Inspection Report
Pictures
PHOTO 3
Description LOOKING EAST TOWARD US ROUTE 34
PHOTO 4
Description NORTH (UPSTREAM) SIDE
Culvert Inspection Report
Pictures
PHOTO 5
Description GENERAL TOPSIDE VIEW LOOKING EAST
PHOTO 6
Description TYPICAL MINOR EROSION AT EAST END OF HEADWALLS - SOUTH HEADWALL SHOWN
Culvert Inspection Report
Pictures
PHOTO 7
Description 3/4" AND 1.5" GAP BETWEEN HEADWALL AND NORTHEAST WINGWALL
PHOTO 8
Description TYPICAL DETERIORATION AND SPALLING ON TOP OF HEADWALLS - NOTE MINOR
VERTICAL CRACKING (SOME WITH EFFLORESCENCE) - DOWNSTREAM HEADWALL
SHOWN
Culvert Inspection Report
Pictures
PHOTO 9
Description UPSTREAM END OF BARREL #1 INVERT IS FOLDED UPWARD 1' HIGH
PHOTO 10
Description GENERAL UNDERSIDE VIEW OF BARREL #1 LOOKING NORTH
Culvert Inspection Report
Pictures
PHOTO 11
Description TYPICAL 1.5" DIAMETER PERFORATIONS IN INVERT OF CORRUGATED METAL PIPE -
BARREL #1 SHOWN
PHOTO 12
Description GENERAL UNDERSIDE OF BARREL #2 LOOKING SOUTH
Culvert Inspection Report
Pictures
PHOTO 13
Description TYPICAL PERFORATIONS IN INVERT - DOWNSTREAM END OF BARREL #2 SHOWN
PHOTO 14
Description GENERAL UNDERSIDE OF BARREL #3 LOOKING SOUTH
Culvert Inspection Report
Pictures
PHOTO 15
Description UPSTREAM END OF BARREL #3 INVERT IS FOLDED UPWARD 1' HIGH
PHOTO 16
Description TYPICAL PERFORATIONS THROUGHOUT INVERT - BARREL #3 SHOWN
Culvert Inspection Report
Pictures
PHOTO 17
Description TYPICAL PERFORATIONS FOUND IN ALL INVERTS NEAR DOWNSTREAM END - BARREL #3
SHOWN
PHOTO 18
Description 1' UNDERMINING AT DOWNSTREAM END OF BARREL #3
Culvert Inspection Report
Pictures
PHOTO 19
Description TYPICAL CONDITION OF SPALLED CONCRETE AT DOWNSTREAM END OF DIVIDER WALL -
DIVIDER WALL #3 SHOWN
PHOTO 20
Description WIDE CRACK IN UPSTREAM END OF DIVIDER WALL #3
Culvert Inspection Report
Pictures
PHOTO 21
Description SEPARATION OF BARREL AND HEADWALL AT UPSTREAM END OF BARREL #4
PHOTO 22
Description GENERAL UNDERSIDE OF BARREL #4 LOOKING SOUTH
Culvert Inspection Report
Pictures
PHOTO 23
Description TYPICAL PERFORATIONS THROUGHOUT INVERT - BARREL #4 SHOWN
PHOTO 24
Description TYPICAL PERFORATIONS IN INVERT NEAR DOWNSTREAM END OF BARREL #4
Culvert Inspection Report
Pictures
PHOTO 25
Description 2.5' UNDERMINING AT OUTLET OF BARREL #4
PHOTO 26
Description SEPARATION OF BARREL AND HEADWALL AT UPSTREAM END OF BARREL #5 - NOTE
DEBRIS
Culvert Inspection Report
Pictures
PHOTO 27
Description UPSTREAM END OF BARREL #5 INVERT IS FOLDED UPWARD PLUS 4 TO 5 SQUARE FEET
OF INVERT IS GONE
PHOTO 28
Description SECTION OF INVERT GONE NEAR UPSTREAM END OF BARREL #5
Culvert Inspection Report
Pictures
PHOTO 29
Description LARGE SECTION OF INVERT GONE 5' FROM UPSTREAM END OF BARREL #5
PHOTO 30
Description GENERAL UNDERSIDE OF BARREL #5 LOOKING SOUTH
Culvert Inspection Report
Pictures
PHOTO 31
Description TYPICAL PERFORATIONS IN INVERT NEAR DOWNSTREAM END OF BARREL #5
PHOTO 32
Description GENERAL UNDERSIDE OF BARREL #6 LOOKING SOUTH - NOTE 8" TO 9" ACCUMULATED
SEDIMENT THROUGHOUT INVERT - CONTROL GATE AT DOWNSTREAM END
Culvert Inspection Report
Pictures
PHOTO 33
Description LARGE PERFORATIONS OF BARREL #6 INVERT WHERE EXPOSED AT UPSTREAM END
PHOTO 34
Description GENERAL VIEW OF CONTROL GATES AT DOWNSTREAM END OF BARREL #6
Culvert Inspection Report
Pictures
PHOTO 35
Description CRAKING AND LARGE SPALL WITH EXPOSED REBAR AT DOWNSTREAM HEADWALL NEAR
BARREL #6
PHOTO 36
Description GENERAL VIEW OF DIVERSION STRUCTURE WITH CONTROL GATES AT DOWNSTREAM
END OF BARREL #6
Culvert Inspection Report
Pictures
PHOTO 37
Description STONES AND GROUT MISSING IN NORTHWEST MASONRY WINGWALL
PHOTO 38
Description VIEW OF STREAM MIGRATION TOWARD NORTHEAST BANK
Culvert Inspection Report
Pictures
PHOTO 39
Description CHANNEL LOOKING UPSTREAM
PHOTO 40
Description CHANNEL LOOKING DOWNSTREAM
File details come from the government source that posted it. Updated .