C04e Geotechnical Study 1240LT26Q0137.pdf

PDF 1 MB Posted

Attached to
Lucky Peak Nursery New Greenhouse
Solicitation number
1240LT26Q0137
Issued by

About this file

This is a geotechnical study report for the proposed Lucky Peak Warehouses project located at 15169 East Highway 21 in Boise, Idaho. The report was prepared by GSH Geotechnical, Inc. and submitted to Case, Lowe & Hart, Inc. on December 7, 2023, under Job No. 1019-044-23.

The project consists of 2 to 3 warehouse/greenhouse structures with footprints of approximately 10,000 to 40,000 square feet, supported on conventional spread and continuous wall footings with slab-on-grade construction. Maximum real column and wall loads are anticipated at 220 kips and 5 to 6 kips per lineal foot, respectively. Associated paved parking areas, light-duty and heavy-duty drive lanes, and loading/unloading areas are planned around the structures. The study involved seven borings to depths ranging from 5.0 to 21.5 feet, plus a stormwater percolation test. Key findings indicate subsurface conditions consist of 6 to 12 inches of topsoil, non-engineered fill soils (1.0 foot in Boring B-6), and natural clay and granular soils below. Auger refusal in bedrock occurred at depths of 18.0 to 21.5 feet. No groundwater was encountered at the depths explored. Recommended bearing capacity for real load conditions is 2,500 pounds per square foot with a 50 percent increase allowable for seismic loading. Specific pavement sections are recommended for parking areas (3.0 inches asphalt/8.0 inches aggregate base), light-duty drive lanes (3.0 inches asphalt/9.0 inches aggregate base), and heavy-duty drive lanes and loading areas (4.0 inches asphalt/8.0 inches aggregate base/8.0 inches aggregate subbase). All site preparation must include removal of topsoil, non-engineered fills, and unsuitable materials, with structural fill compacted to 90-96 percent of maximum dry density depending on location. The site is not subject to liquefaction risk, and Type I or IA cement may be used for concrete in contact with site soils based on negligible water-soluble sulfate content.

View the file

Other files

Show all 20

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

REPORT

GEOTECHNICAL STUDY

PROPOSED LUCKY PEAK WAREHOUSES

15169 EAST HIGHWAY 21

BOISE, IDAHO

Submitted To:

Case, Lowe & Hart, Inc.

2484 Washington Boulevard, Suite 510

Ogden, Utah 84401

Submitted By:

GSH Geotechnical, Inc.

473 West 4800 South

Salt Lake City, Utah 84123

December 7, 2023

Job No. 1019-044-23

473 West 4800 South Salt Lake City, Utah 84123 Tel: 801.685.9190 Fax: 801.685.2990 www.gshgeo.com

Mr. Steve Peterson

2484 Washington Boulevard, Suite 510 Ogden, Utah 84401

Mr. Peterson:

Re: Report

Geotechnical Study Proposed Lucky Peak Warehouses 15169 East Highway 21 Boise, Idaho

1. INTRODUCTION

1.1 GENERAL

This report presents the results of our geotechnical study performed at the site of the proposed Lucky Peak Warehouses to be located at 15169 East Highway 21 in Boise, Idaho. The general location of the site with respect to existing roadways, as of 2023, is presented on Figure 1, Vicinity Map. A more detailed layout of the site showing proposed facilities, existing roadways, and the borings drilled in conjunction with this study is presented on Figure 2, Site Plan.

1.2 OBJECTIVES AND SCOPE

The objectives and scope of the study were planned in discussions between Mr. Steve Peterson of Case, Lowe & Hart, Inc. and Mr. Robert Gifford of GSH Geotechnical, Inc. (GSH).

In general, the objectives of this study were to:

1. Define and evaluate the subsurface soil and groundwater conditions across the site.

2. Provide appropriate foundation, earthwork, pavement, stormwater percolation, and geoseismic recommendations to be utilized in the design and construction of the proposed facilities.

http://www.gshgeo.com/

Geotechnical Study – Proposed Lucky Peak Warehouses

In accomplishing these objectives, our scope has included the following:

1. A field program consisting of the exploration, logging, and sampling of 7 borings, as well as performing an on-site wastewater percolation test.

2. A laboratory testing program.

3. An office program consisting of the correlation of available data, engineering analysis, and the preparation of this summary report.

1.3 AUTHORIZATION

Authorization was provided by returning a signed copy of the Professional Services Agreement No. 23-0911 dated September 6, 2023.

1.4 PROFESSIONAL STATEMENTS

Supporting data upon which our recommendations are based are presented in subsequent sections of this report. Recommendations presented herein are governed by the physical properties of the soils encountered in the exploration borings, projected groundwater conditions, and the layout and design data discussed in Section 2, Proposed Construction. If subsurface conditions other than those described in this report are encountered and/or if design and layout changes are implemented, GSH must be informed so that our recommendations can be reviewed and amended, if necessary.

Our professional services have been performed, our findings developed, and our recommendations prepared in accordance with generally accepted engineering principles and practices in this area at this time.

2. PROPOSED CONSTRUCTION

The project is to consist of the construction of 2 to 3 warehouse/greenhouse structures with footprints of approximately 10,000 to 40,000 square feet and associated pavements. The structures are anticipated to one extended level of steel framing and/or tilt-up concrete construction, to be placed slab-on-grade, and supported upon conventional spread and continuous wall footings.

Maximum real column and wall loads are anticipated to be on the order of up to 220 kips and 5 to 6 kips per lineal foot, respectively. Real loads are defined as the total of all dead plus frequently applied (reduced) live loads.

Paved parking areas, light- and heavy-duty drive lanes, and loading/unloading areas are planned around the structures. Projected traffic in the parking areas is anticipated to consist of a light volume of automobiles and light trucks, occasional medium-weight trucks, and no heavyweight trucks. Proposed traffic in the light-duty drive lanes is anticipated to consist of a moderate volume of automobiles and light trucks, a light volume of medium-weight trucks, and occasional heavyweight trucks. Projected traffic in the heavy-duty drive lanes and loading/unloading areas is anticipated to consist of a moderate volume of automobiles, light trucks, and medium-weight trucks with a light volume of heavyweight trucks.

Site development will require some earthwork in the form of minor cutting and filling. At this time, we anticipate that maximum site grading cuts and fills, excluding utilities, will be on the order of 1 to 3 feet.

3. SITE INVESTIGATIONS

3.1 GENERAL

Subsurface conditions in unexplored locations or at other times may vary from those encountered at specific boring locations. If such variations are noted during construction or if project development plans are changed, GSH must review the changes and amend our recommendations, if necessary.

Boring locations were established by estimating distances and angles from site landmarks. If increased accuracy is desired by the client, we recommend that the boring locations and elevations be surveyed.

3.2 FIELD PROGRAM

To define and evaluate the subsurface soil and groundwater conditions across the site, 7 borings were completed within the accessible areas. These borings were completed to depths ranging from

5.0 to 21.5 feet with a truck-mounted drill rig equipped with hollow-stem augers. Auger refusal within bedrock terminated Borings B-1 and B-2. The approximate locations of the borings are presented on Figure 2. Additionally, a stormwater percolation test to determine the percolation rate was performed in Boring B-7 at a depth of 5.0 feet.

The field portion of our study was under the direct control and continual supervision of an experienced member of our geotechnical staff. During the course of the drilling operations, a continuous log of the subsurface conditions encountered was maintained. In addition, samples of the typical soils encountered were obtained for subsequent laboratory testing and examination. The soils were classified in the field based upon visual and textural examination. These classifications were supplemented by subsequent inspection and testing in our laboratory. Graphical representation of the subsurface conditions encountered is presented on Figures 3A through 3G, Boring Logs. Soils were classified in accordance with the nomenclature described on Figure 4, Key to Boring Log (USCS).

A 3.25-inch outside diameter, 2.42-inch inside diameter (Dames & Moore) and a 2.0-inch outside diameter, 1.38-inch inside diameter drive sampler (SPT) were utilized at select locations and depths. The blow counts recorded on the boring logs were those required to drive the sampler 12 inches with a 140-pound hammer dropping 30 inches.

Following completion of exploration operations, 1.25-inch diameter slotted PVC pipe was installed in Boring B-3 to provide a means of monitoring the groundwater fluctuations. The borings were backfilled with auger cuttings.

3.3 LABORATORY TESTING

3.3.1 General

To provide data necessary for our engineering analysis, a laboratory testing program was performed. This program included moisture, density, partial gradation, consolidation, and chemical tests. The following paragraphs describe the tests and summarize the test data.

3.3.2 Moisture and Density Tests

To provide index parameters and to correlate other test data, moisture and density tests were performed on selected samples. The results of these tests are presented on the boring logs, Figures 3A through 3G.

3.3.3 Partial Gradation Tests

To aid in classifying the granular soils, partial gradation tests were performed. Results of the tests are tabulated below and presented on the boring logs, Figures 3A through 3G:

Boring No.

Depth (feet)

Percent Passing No. 200 Sieve

Moisture Content Percent

Soil Classification

B-1 2.5 32.7 6.3 SM

B-1 10.0 20.6 10.4 SM/SC

B-3 15.0 18.4 13.7 SP*

B-4 5.0 26.7 13.1 SM/SC

B-5 15.0 13.4 8.2 GP*

B-7 5.0 55.2 9.9 CL

*sample contained layer of clay

3.3.4 Consolidation Tests

To provide data necessary for our settlement analysis, consolidation testing was performed on 2 representative samples of the natural fine-grained clay soils encountered at the site. The results of these tests indicate that the samples tested were moderately over-consolidated and will exhibit moderate strength and compressibility characteristics under the anticipated loading. Detailed results of the tests are maintained within our files and can be transmitted to you, upon your request.

3.3.5 Chemical Tests

To determine if the site soils will react detrimentally with concrete, chemical tests were performed on a representative sample of the near-surface soil encountered at the site. The results of the chemical tests are tabulated below:

Boring No.

Depth (feet)

Soil Classification pH

Total Water-Soluble Sulfate (mg/kg-dry)

B-1 2.5 SM 8.2 Not Detected

4. SITE CONDITIONS

4.1 SURFACE

The site is located at 15169 East Highway 21 in Boise, Idaho. The site is currently vacant/undeveloped alfalfa fields used for agricultural purposes in the central portion with an unpaved dirt road as well as equipment storage areas in the northern portion. The topography of the site is relatively flat, grading down to the southeast with a total relief of approximately 10 to 12 feet. Site vegetation consists of various weeds and brush/grass with a line of mature trees along the eastern border.

The site is bounded to the north by vacant/undeveloped brush/grass land; to the east by an unpaved dirt road followed by an equipment storage area with vacant/undeveloped brush/grass land and a pond beyond; to the south by an unpaved dirt road followed by vacant/undeveloped brush/grass land; and to the west by existing greenhouse/commercial structures followed by an unpaved dirt road as well as agricultural grass fields.

4.2 SUBSURFACE SOIL

The following paragraphs provide generalized descriptions of the subsurface profiles and soil conditions encountered within the borings conducted during this study. As previously noted, soil conditions may vary in unexplored locations.

The borings were completed to depths ranging from 5.0 to 21.5 feet. The soil conditions encountered in each of the borings, to the depths completed, were generally similar across the boring locations.

• Approximately 6 to 12 inches of topsoil was encountered in each boring. Topsoil thickness is frequently erratic and thicker zones of topsoil should be anticipated.

• Non-engineered fill soils were encountered in Boring B-6, to a depth of 1.0 feet beneath the existing ground surface. The non-engineered fill soils consisted of clay with silt, sand, and gravel.

• Natural soils were encountered below the non-engineered fill or the ground surface in each boring. The natural soils consisted primarily of clay with varying silt and sand content as well as sand and gravel with varying clay and silt content.

• Auger refusal occurred within the bedrock in Borings B-1 and B-2 at depths of 18.0 to

21.5 feet below the existing ground surface, respectively.

The natural clay soils were medium stiff to stiff, dry to slightly moist, black, tan, and brown in color, and moderately over-consolidated. The natural clay soils are anticipated to exhibit moderate strength and compressibility characteristics under the anticipated loading.

The natural granular soils were loose to very dense, slightly moist to moist, and tan and brown in color. The natural sand soils are anticipated to exhibit moderately high strength and moderately low compressibility characteristics under the anticipated load range.

For a more descriptive interpretation of subsurface conditions, please refer to Figures 3A through 3G, Boring Logs. The lines designating the interface between soil types on the boring logs generally represent approximate boundaries. In situ, the transition between soil types may be gradual.

4.3 GROUNDWATER

Groundwater was not encountered to the depths explored in the borings completed at the site.

Groundwater levels vary with changes in season and rainfall, construction activity, irrigation, snow melt, surface water run-off, and other site-specific factors.

5. DISCUSSIONS AND RECOMMENDATIONS

5.1 SUMMARY OF FINDINGS

The proposed structures may be supported upon conventional spread and continuous wall foundations supported upon suitable natural soils and/or structural fill extending to suitable natural soils.

The most significant geotechnical aspects at the site are:

1. The existing non-engineered fills encountered at the site.

2. The potential to encounter additional non-engineered fill at the site.

Prior to proceeding with construction, removal of any existing debris, surface vegetation, root systems, topsoil, non-engineered fill, and any deleterious materials from beneath an area extending out at least 5 feet from the perimeter of the proposed structure footprints and 3 feet beyond pavements and exterior flatwork areas will be required. All existing utility locations should be reviewed to assess their impact on the proposed construction and abandoned and/or relocated as appropriate.

Due to the developed nature of this site and the surrounding area, additional non-engineered fills may exist in unexplored areas of the site. Based on our experience, non-engineered fills are frequently erratic in composition and consistency. All surficial loose/disturbed soils and non-engineered fills must be removed below all footings, floor slabs, and pavements.

On-site granular soils may be re-utilized as structural site grading fill if they meet the criteria for such, as stated later in this report.

Detailed discussions pertaining to earthwork, foundations, pavements, and the geoseismic setting of the site are presented in the following sections.

5.2 EARTHWORK

5.2.1 Site Preparation

Initial site preparation will consist of the removal of any existing debris, non-engineered fills, surface vegetation, root systems, topsoil, and any deleterious materials from beneath an area extending out at least 5 feet from the perimeter of the proposed structure footprint and 3 feet beyond pavements and exterior flatwork areas. All existing utility locations should be reviewed to assess their impact on the proposed construction and abandoned and/or relocated as appropriate.

Subsequent to stripping and prior to the placement of floor slabs, foundations, structural site grading fills, exterior flatwork, and pavements, the exposed subgrade must be proof rolled by passing moderate-weight rubber tire-mounted construction equipment over the surface at least twice. If excessively soft or otherwise unsuitable soils are encountered beneath footings, they must be completely removed. If removal depth required is greater than 2 feet below footings, GSH must be notified to provide further recommendations. In pavement, floor slab, and outside flatwork areas, unsuitable natural soils shall be removed to a maximum depth of 2 feet and replaced with compacted granular structural fill.

Subgrade preparation as described must be completed prior to placing overlying structural site grading fills.

GSH must be notified prior to the placement of structural site grading fills, floor slabs, footings, and pavements to verify that all loose/disturbed soils and non-engineered fills have been completely removed.

5.2.2 Temporary Excavations

Temporary excavations up to 8 feet deep in fine-grained cohesive soils, above or below the water table, may be constructed with sideslopes no steeper than one-half horizontal to one vertical (0.5H:1.0V). Excavations deeper than 8 feet are not anticipated at the site.

For granular (cohesionless) soils, construction excavations above the water table, not exceeding 4 feet, shall be no steeper than one-half horizontal to one vertical (0.5H:1.0V). For excavations up to 8 feet, in granular soils and above the water table, the slopes shall be no steeper than one horizontal to one vertical (1H:1V). Excavations encountering saturated cohesionless soils will be very difficult and will require very flat sideslopes and/or shoring, bracing, and dewatering.

All excavations must be inspected periodically by qualified personnel. If any signs of instability or excessive sloughing are noted, immediate remedial action must be initiated.

5.2.3 Structural Fill

Structural fill is defined as all fill which will ultimately be subjected to structural loadings, such as imposed by footings, floor slabs, pavements, etc. Structural fill will be required as backfill over foundations and utilities, as site grading fill, and as replacement fill below footings. All structural fill must be free of surface vegetation, root systems, rubbish, topsoil, frozen soil, and other deleterious materials.

Structural site grading fill is defined as structural fill placed over relatively large open areas to raise the overall grade. For structural site grading fill, the maximum particle size shall not exceed 4 inches; although, occasional larger particles, not exceeding 8 inches in diameter, may be incorporated if placed randomly in a manner such that “honeycombing” does not occur, and the desired degree of compaction can be achieved. The maximum particle size within structural fill placed within confined areas shall be restricted to 2 inches.

On-site soils, including existing non-engineered fills, may be re-utilized as structural site grading fill if they do not contain construction debris or deleterious material and meet the requirements of structural fill. Fine-grained soils will require very close moisture control and may be very difficult, if not impossible, to properly place and compact during wet and cold periods of the year.

Imported structural fill below foundations and floor slabs shall consist of a well graded sand and gravel mixture with less than 30 percent retained on the three-quarter-inch sieve and less than 20 percent passing the No. 200 Sieve (clays and silts).

To stabilize soft subgrade conditions (if encountered) or where structural fill is required to be placed closer than 2.0 feet above the water table at the time of construction, a mixture of coarse angular gravels and cobbles and/or 1.5- to 2.0-inch gravel (stabilizing fill) shall be utilized. It may also help to utilize a stabilization fabric, such as Mirafi 600X or equivalent, placed on the natural ground if 1.5- to 2.0-inch gravel is used as stabilizing fill.

5.2.4 Fill Placement and Compaction

All structural fill shall be placed in lifts not exceeding 8 inches in loose thickness. Structural fills shall be compacted in accordance with the percent of the maximum dry density as determined by the AASHTO1 T180 (ASTM2 D1557) compaction criteria in accordance with the following table:

Location Total Fill Thickness

(feet)

Minimum Percentage of Maximum Dry Density

Beneath an area extending at least 5 feet beyond the perimeter of the structure 0 to 5 95

Site grading fills outside area defined above 0 to 5 90

Utility trenches within structural areas -- 96

Road base -- 96

Structural fills greater than 5 feet thick are not anticipated at the site.

Subsequent to stripping and prior to the placement of structural site grading fill, the subgrade shall be prepared as discussed in Section 5.2.1, Site Preparation, of this report. In confined areas, subgrade preparation shall consist of the removal of all loose or disturbed soils.

Coarse angular gravel and cobble mixtures (stabilizing fill), if utilized, shall be end dumped, spread to a maximum loose lift thickness of 15 inches, and compacted by dropping a backhoe bucket onto the surface continuously at least twice. As an alternative, the stabilizing fill may be compacted by passing moderately heavy construction equipment or large self-propelled compaction equipment over the surface at least twice. Subsequent fill material placed over the coarse gravels and cobbles shall be adequately compacted so that the “fines” are “worked into” the voids in the underlying coarser gravels and cobbles. Where soil fill materials are to be placed directly over more than about 18 inches of clean gravel, a separation geofabric, such as Mirafi 140N or equivalent, is recommended to be placed between the gravel and subsequent soil fills.

Non-structural fill may be placed in lifts not exceeding 12 inches in loose thickness and compacted by passing construction, spreading, or hauling equipment over the surface at least twice.

5.2.5 Utility Trenches

All utility trench backfill material below structurally loaded facilities (footings, floor slabs, flatwork, pavements, etc.) shall be placed at the same density requirements established for

1 American Association of State Highway and Transportation Officials 2 American Society for Testing and Materials structural fill. If the surface of the backfill becomes disturbed during the course of construction, the backfill shall be proof rolled and/or properly compacted prior to the construction of any exterior flatwork over a backfilled trench. Proof rolling shall be performed by passing moderately loaded rubber tire-mounted construction equipment uniformly over the surface at least twice. If excessively loose or soft areas are encountered during proof rolling, they shall be removed to a maximum depth of 2 feet below design finish grade and replaced with structural fill.

Many utility companies and City-County governments are now requiring that Type A-1a or A-1b (AASHTO Designation – granular soils with limited fines) soils be used as backfill over utilities.

These organizations are also requiring that in public roadways, the backfill over major utilities be compacted over the full depth of fill to at least 96 percent of the maximum dry density as determined by the AASHTO T180 (ASTM D1557) method of compaction. GSH recommends that as the major utilities continue onto the site that these compaction specifications are followed.

Fine-grained soils, such as silts and clays, are not recommended for utility trench backfill in structural areas.

5.3 GROUNDWATER

Groundwater was not encountered to the depths explored in the borings completed at the site.

The groundwater measurements presented are conditions at the time of the field exploration and may not be representative of other times or locations. Groundwater levels may vary seasonally and with precipitation, as well as other factors including irrigation. Evaluation of these factors is beyond the scope of this study. Groundwater levels may, therefore, be at shallower or deeper depths than those measured during this study, including during construction and over the life of the structure.

The extent and nature of any dewatering required during construction will be dependent on the actual groundwater conditions prevalent at the time of construction and the effectiveness of construction drainage to prevent run-off into open excavations.

5.3.1 Onsite Wastewater Percolation Test

An onsite wastewater percolation test was performed at a depth of approximately 5 feet in the representative natural silt loam soils at Boring B-7. The field percolation rate was 20 minutes per inch. This design percolation rate should be considered typical for the soils at the site.

5.4 SPREAD AND CONTINUOUS WALL FOUNDATIONS

5.4.1 Design Data

The results of our analysis indicate that the proposed structures may be supported upon conventional spread and continuous wall foundations established upon suitable natural soils and/or structural fill extending to suitable natural soils. Under no circumstances shall foundations be established over non-engineered fills, loose or disturbed soils, topsoil, surface vegetation, root systems, rubbish, construction debris, other deleterious materials, frozen soils, or within ponded water. For design, the following parameters are provided:

Minimum Recommended Depth of Embedment for

Frost Protection - 30 inches

Minimum Recommended Depth of Embedment for Non-frost Conditions - 15 inches

Recommended Minimum Width for Continuous Wall Footings - 18 inches

Minimum Recommended Width for Isolated Spread Footings - 24 inches

Recommended Net Bearing Capacity for Real Load Conditions - 2,500 pounds per square foot

Bearing Capacity Increase for Seismic Loading - 50 percent

The term “net bearing capacity” refers to the allowable pressure imposed by the portion of the structure located above lowest adjacent final grade. Therefore, the weight of the footing and backfill to lowest adjacent final grade need not be considered. Real loads are defined as the total of all dead plus frequently applied live loads. Total load includes all dead and live loads, including seismic and wind.

5.4.2 Installation

Under no circumstances shall the footings be installed upon non-engineered fills, loose or disturbed soils, topsoil, surface vegetation, root systems, rubbish, construction debris, or other deleterious materials. If unsuitable soils are encountered, they must be removed and replaced with compacted granular fill. If granular soils become loose or disturbed, they must be recompacted prior to pouring the concrete.

The width of structural replacement fill below footings shall be equal to the width of the footing plus one foot for each foot of fill thickness.

5.4.3 Settlements

Based on column loadings, soil bearing capacities, and the foundation recommendations as discussed above, we expect primary total settlement beneath individual foundations to be less than one inch.

The amount of differential settlement is difficult to predict because the subsurface and foundation loading conditions can vary considerably across the site. However, we anticipate differential settlement between adjacent foundations could vary from 0.5 to 0.75 inch. The final deflected shape of the structure will be dependent on actual foundation locations and loading.

5.5 LATERAL RESISTANCE

Lateral loads imposed upon foundations due to wind or seismic forces may be resisted by the development of passive earth pressures and friction between the base of the footings and the supporting soils. In determining frictional resistance, a coefficient of friction of 0.35 may be utilized for the footing interface with in-situ natural clay soils and 0.40 for footing interface with natural granular soils or granular structural fill. Passive resistance provided by properly placed and compacted granular structural fill above the water table may be considered equivalent to a fluid with a density of 300 pounds per cubic foot. Below the water table, this granular soil shall be considered equivalent to a fluid with a density of 150 pounds per cubic foot.

A combination of passive earth resistance and friction may be utilized provided that the friction component of the total is divided by 1.5.

5.6 FLOOR SLABS

Floor slabs may be established upon suitable natural subgrade soils or structural fill extending to suitable natural soils. Under no circumstances shall floor slabs be established directly over non-engineered fills, loose or disturbed soils, sod, rubbish, construction debris, other deleterious materials, frozen soils, or within ponded water.

To facilitate curing of the concrete and to provide a capillary moisture break, it is recommended that floor slabs be directly underlain by at least 4 inches of “free-draining” fill, such as “pea” gravel or three-quarters to one inch minus clean gap-graded gravel.

Settlement of lightly loaded floor slabs designed according to previous recommendations (average uniform pressure of 200 pounds per square foot or less) is anticipated to be less than one-quarter of an inch.

5.7 PAVEMENTS

The natural clay soils will exhibit poor pavement support characteristics when saturated. All pavement areas must be prepared as previously discussed (see Section 5.2.1, Site Preparation).

Under no circumstances shall pavements be established over non-engineered fills, loose or disturbed soils, topsoil, surface vegetation, root systems, rubbish, construction debris, other deleterious materials, frozen soils, or within ponded water. With the subgrade soils and the estimated projected traffic as discussed in Section 2, Proposed Construction, the following pavement sections are recommended:

Parking Areas

(650 Automobiles and Light Trucks, 3 Medium-Weight Trucks, and 0 Heavyweight Trucks)

[7 equivalent 18-kip axle loads per day]

Flexible Pavements:

(Asphalt Concrete)

3.0 inches Asphalt concrete

8.0 inches Aggregate base

Over Properly prepared natural subgrade soils and/or structural site grading fill extending to properly prepared natural subgrade soils

Rigid Pavements:

(Non-reinforced Concrete)

5.0 inches Portland cement concrete

(non-reinforced)

5.0 inches Aggregate base

Light-Duty Drive Lanes

(675 Automobiles and Light Trucks, 5 Medium-Weight Trucks, and 2 Heavyweight Trucks)

[15 equivalent 18-kip axle loads per day]

3.0 inches Asphalt concrete

9.0 inches Aggregate base

6.0 inches Portland cement concrete

6.0 inches Aggregate base

Heavy-Duty Drive Lanes and Loading/Unloading Areas

(675 Automobiles and Light Trucks, 25 Medium-Weight Trucks, and 17 Heavyweight Trucks)

[71 equivalent 18-kip axle loads per day]

4.0 inches Asphalt concrete

8.0 inches Aggregate base

8.0 inches* Aggregate subbase

Over Properly prepared natural subgrade soils

* Subbase may consist of granular site grading fills with a minimum California Bearing Ratio

(CBR) of 30 percent.

7.0 inches Portland cement concrete

6.0 inches Aggregate base

For dumpster pads, we recommend a pavement section consisting of 8.0 inches of Portland cement concrete, 12.0 inches of aggregate base, over properly prepared natural subgrade or site grading structural fills. Dumpster pads shall not be constructed overlying non-engineered fills under any circumstances.

These above rigid pavement sections are for non-reinforced Portland cement concrete. Concrete shall be designed in accordance with the American Concrete Institute (ACI) and joint details shall conform to the Portland Cement Association (PCA) guidelines. The concrete shall have a minimum 28-day unconfined compressive strength of 4,000 pounds per square inch and contain 6 percent ±1 percent air-entrainment.

The crushed stone shall conform to applicable sections of the current Idaho Transportation Department (ITD) Standard Specifications. All asphalt material and paving operations shall meet applicable specifications of the Asphalt Institute and ITD. A GSH technician shall observe placement and perform density testing of the base course material and asphalt.

Please note that the recommended pavement section is based on estimated post-construction traffic loading. If the pavement is to be constructed and utilized by construction traffic, the above pavement section may prove insufficient for heavy truck traffic, such as concrete trucks or tractor-trailers used for construction delivery. Unexpected distress, reduced pavement life, and/or premature failure of the pavement section could result if subjected to heavy construction traffic and the owner should be made aware of this risk. If the estimated traffic loading stated herein is not correct, GSH must review actual pavement loading conditions to determine if revisions to these recommendations are warranted.

5.8 CEMENT TYPES

The laboratory tests indicate that the natural soils tested contain a negligible amount of water-soluble sulfates. Based on our test results, concrete in contact with the on-site soil will have a low potential for sulfate reaction (ACI 318, Table 4.3.1). Therefore, all concrete which will be in contact with the site soils may be prepared using Type I or IA cement.

5.9 GEOSEISMIC SETTING

5.9.1 General

Idaho municipalities have adopted the International Building Code (IBC) 2018. The IBC 2018 code refers to ASCE 7-16 Minimum Design Loads and Associated Criteria for Buildings and Other Structures (ASCE 7-16) determines the seismic hazard for a site based upon mapping of bedrock accelerations prepared by the United States Geologic Survey (USGS) and the soil site class. The USGS values are presented on maps incorporated into the IBC code and are also available based on latitude and longitude coordinates (grid points).

5.9.2 Faulting

Based on our review of available literature, no active faults pass through or immediately adjacent to the site. The nearest active mapped fault consists of the Squaw Creek Fault, located about

33.8 miles to the northwest of the site.

5.9.3 Site Class

For dynamic structural analysis, the Site Class D – Default Soil Profile as defined in Chapter 20 of ASCE 7-16 (per Section 1613.3.2, Site Class Definitions, of IBC 2021) can be utilized. If a measured site class is desired based on the project structural engineer’s evaluation and recommendations, additional testing and analysis can be completed by GSH to determine the measured site class. Please contact GSH for additional information.

5.9.4 Ground Motions

The IBC 2018 code is based on USGS mapping, which provides values of short and long period accelerations for average bedrock values for the Western United States and must be corrected for local soil conditions. The following table summarizes the peak ground and short and long period accelerations for the MCE event and incorporates the appropriate soil amplification factor for a Site Class D – Default* Soil Profile. Based on the site latitude and longitude (43.5803 degrees north and 115.9897 degrees west, respectively) and Risk Category I, the values for this site are tabulated below:

Spectral Acceleration

Value, T

0.2 Seconds

(Short Period Acceleration)

SS = 35.6 Fa = 1.515 SMS = 54.0 SDS = 36.0

1.0 Second

(Long Period Acceleration)

S1 = 12.0 Fv = 2.361 SM1 = 28.3 SD1 = 18.9

Bedrock

Site Coefficient

Design Values**

(% g)(% g) [mapped values]

Boundary Site Class D - Default*

(% g) class effects]

[adjusted for site

* If a measured site class in accordance with IBC 2018/ASCE 7-16 is beneficial based on the project structural engineer’s review, please contact GSH for additional options for obtaining this measured site class.

**IBC 2018/ASCE 7-16 may require a site-specific study based on the project structural engineer’s evaluation and recommendations. If needed, GSH can provide additional information and analysis including a complete site-specific study in accordance with chapter 21 of ASCE 7-16.

5.9.5 Liquefaction

Liquefaction is defined as the condition when saturated, loose, granular soils lose their support capabilities because of excessive pore water pressure, which develops during a seismic event.

Clayey soils, even if saturated, will generally not liquefy during a major seismic event.

Due to the density of the granular soils and the lack of groundwater, liquefaction is not anticipated to occur within the soils encountered at this site.

5.10 SITE VISITS

GSH must verify that all topsoil/disturbed soils, non-engineered fills, and any other unsuitable soils have been removed and that suitable soils have been encountered prior to placing site grading fills, footings, slabs, and pavements. Additionally, GSH must observe fill placement and verify in-place moisture content and density of fill materials placed at the site.

6. CLOSURE

If you have any questions or would like to discuss these items further, please feel free to contact us at (801) 685-9190.

Respectfully submitted, Michael S. Huber, P.E.

State of Idaho No. 17459 Vice President/Senior Geotechnical Engineer

MSH/ADS:jmt

Encl. Figure 1, Vicinity Map

Figure 2, Site Plan Figures 3A through 3G, Boring Logs Figure 4, Key to Boring Log (USCS)

Addressee (email)

REFERENCE:

ALL TRAILS - NATIONAL GEOGRAPHIC TERRAIN

DATED 2023

CASE, LOWE & HART, INC.

JOB NO. 1019-044-23

SITE

FIGURE 1

VICINITY MAP

35 350 70

APPROXIMATE SCALE IN FEET

CASE, LOWE & HART, INC.

JOB NO. 1019-044-23

REFERENCE:

ADAPTED FROM DRAWING ENTITLED

“LUCKY PEAK NURSERY GREENHOUSE AREA, X-01”

BY USDA FOREST SERVICE, DATED 05/04/2023

FIGURE 2

SITE PLAN

B-1

B-2

B-3

B-4

B-5

B-6 B-7

BORING: B-1

PROJECT NUMBER: 1019-044-23

DATE STARTED: 10/12/23 DATE FINISHED: 10/12/23

LOCATION: 15169 East Highway 21, Boise, Idaho (43.5803°, -115.9897°) GSH FIELD REP.: TL

DRILLING METHOD/EQUIPMENT: 6-1/4" ID Hollow-Stem Auger HAMMER: Automatic WEIGHT: 140 lbs DROP: 30"

GROUNDWATER DEPTH: Not Encountered (10/12/23) ELEVATION: ---

CL dry medium stiff

SM slightly moist medium dense

SM/ slightly moist SC medium dense

GP slightly moist very dense

See Subsurface Conditions section in the report for additional information. FIGURE 3A

SILTY CLAY

with trace clay; brown

PROJECT: Proposed Lucky Peak Warehouses

CLIENT: Case, Lowe & Hart, Inc.

BORING LOG

Page: 1 of 1 with fine sand; major roots (topsoil) to 6"; brown

REMARKSDESCRIPTION

SILTY FINE TO COARSE SAND

Ground Surface

SILTY FINE TO MEDIUM SAND

with some silty clay; brown

No groundwater encountered at time of drilling.

grades with layers of fine and coarse gravel up to 2" thick

FINE AND COARSE GRAVEL

with fine to coarse sand and trace silty clay; brown grades to bedrock Refusal at 18.0' on bedrock.

W A

T E

R L

E V

E L

U S C S D

E P

T H

(F T

B L

O W

C O

U N

T

SA

M

P L

E S

Y M

B O

L

M O

IS

T

U R

E

D R

Y D

E N

SI

T

Y

P C

F

P

A

SS

IN

G

L

IQ

U

ID

L

IM

IT

P L

A

ST

IC

IT

Y I

N D

E X

50/1"

50/1.5"

6.3

7.8

10.4

32.7

20.6

BORING: B-2

DATE STARTED: 10/12/23 DATE FINISHED: 10/12/23

LOCATION: 15169 East Highway 21, Boise, Idaho (43.5803°, -115.9897°) GSH FIELD REP.: TL

DRILLING METHOD/EQUIPMENT: 6-1/4" ID Hollow-Stem Auger HAMMER: Automatic WEIGHT: 140 lbs DROP: 30"

GROUNDWATER DEPTH: Not Encountered (10/12/23) ELEVATION: ---

CL slightly moist medium stiff

SM/ slightly moist SC medium dense

SP/ slightly moist SM medium dense

CL slightly moist stiff

SP slightly moist very dense

See Subsurface Conditions section in the report for additional information. FIGURE 3B grades to bedrock Refusal at 21.5 on bedrock.

No groundwater encountered at time of drilling.

FINE TO COARSE SAND

with layers of silty clay up to 2" thick; brown grades with layers of fine and coarse gravel up to 6" thick

FINE TO MEDIUM SANDY CLAY

black

FINE TO COARSE SAND

with some silt and fine and coarse gravel; brown gravel grades out

SILTY FINE TO COARSE SAND

with fine and coarse gravel and some silty clay; brown

DESCRIPTION REMARKS

Ground Surface

FINE SANDY CLAY

with major roots (topsoil) to 12"; brown

CLIENT: Case, Lowe & Hart, Inc.

PROJECT: Proposed Lucky Peak Warehouses

BORING LOG

Page: 1 of 1

W A

T E

R L

E V

E L

U S C S D

E P

T H

(F T

B L

O W

C O

U N

T

SA

M

P L

E S

Y M

B O

L

M O

IS

T

U R

E

D R

Y D

E N

SI

T

Y

P C

F

P

A

SS

IN

G

L

IQ

U

ID

L

IM

IT

P L

A

ST

IC

IT

Y I

N D

E X

50+

5.6

14.9

BORING: B-3

DATE STARTED: 10/12/23 DATE FINISHED: 10/12/23

LOCATION: 15169 East Highway 21, Boise, Idaho (43.5803°, -115.9897°) GSH FIELD REP.: TL

DRILLING METHOD/EQUIPMENT: 6-1/4" ID Hollow-Stem Auger HAMMER: Automatic WEIGHT: 140 lbs DROP: 30"

GROUNDWATER DEPTH: Not Encountered (10/12/23) ELEVATION: ---

SM/ slightly moist SC medium dense

SP slightly moist medium dense loose

See Subsurface Conditions section in the report for additional information. FIGURE 3C

End of Exploration at 16.5'.

No groundwater encountered at time of drilling.

Installed 1.25" diameter slotted PVC pipe to 16.5'.

grades with layers of silty clay up to 4" thick; brown grades with layers of silty clay with some fine sand up to 6" thick grades with fine gravel

FINE TO COARSE SAND

with trace silt; tan

DESCRIPTION REMARKS

Ground Surface

SILTY/CLAYEY FINE TO MEDIUM SAND

with major roots (topsoil) to 12"; tan

CLIENT: Case, Lowe & Hart, Inc.

PROJECT: Proposed Lucky Peak Warehouses

BORING LOG

Page: 1 of 1

W A

T E

R L

E V

E L

U S C S D

E P

T H

(F T

B L

O W

C O

U N

T

SA

M

P L

E S

Y M

B O

L

M O

IS

T

U R

E

D R

Y D

E N

SI

T

Y

P C

F

P

A

SS

IN

G

L

IQ

U

ID

L

IM

IT

P L

A

ST

IC

IT

Y I

N D

E X

15.8

8.6

13.7

18.4

BORING: B-4

DATE STARTED: 10/12/23 DATE FINISHED: 10/12/23

LOCATION: 15169 East Highway 21, Boise, Idaho (43.5803°, -115.9897°) GSH FIELD REP.: TL

DRILLING METHOD/EQUIPMENT: 6-1/4" ID Hollow-Stem Auger HAMMER: Automatic WEIGHT: 140 lbs DROP: 30"

GROUNDWATER DEPTH: Not Encountered (10/12/23) ELEVATION: ---

CL slightly moist medium stiff

SM/ slightly moist SC medium dense

GP slightly moist dense

See Subsurface Conditions section in the report for additional information. FIGURE 3D

End of Exploration at 16.5'.

No groundwater encountered at time of drilling.

with fine to coarse sand; brown grades to bedrock

FINE AND COARSE GRAVEL

SILTY FINE TO COARSE SAND

with some silty clay; brown

DESCRIPTION REMARKS

Ground Surface

SILTY CLAY

with fine to medium sand; brown

CLIENT: Case, Lowe & Hart, Inc.

PROJECT: Proposed Lucky Peak Warehouses

BORING LOG

Page: 1 of 1

W A

T E

R L

E V

E L

U S C S D

E P

T H

(F T

B L

O W

C O

U N

T

SA

M

P L

E S

Y M

B O

L

M O

IS

T

U R

E

D R

Y D

E N

SI

T

Y

P C

F

P

A

SS

IN

G

L

IQ

U

ID

L

IM

IT

P L

A

ST

IC

IT

Y I

N D

E X

13.1

26.7

BORING: B-5

DATE STARTED: 10/12/23 DATE FINISHED: 10/12/23

LOCATION: 15169 East Highway 21, Boise, Idaho (43.5803°, -115.9897°) GSH FIELD REP.: TL

DRILLING METHOD/EQUIPMENT: 6-1/4" ID Hollow-Stem Auger HAMMER: Automatic WEIGHT: 140 lbs DROP: 30"

GROUNDWATER DEPTH: Not Encountered (10/12/23) ELEVATION: ---

CL slightly moist medium stiff

SM/ slightly moist SC very dense

GP slightly moist dense medium dense

See Subsurface Conditions section in the report for additional information. FIGURE 3E

End of Exploration at 16.5'.

No groundwater encountered at time of drilling.

grades with layers of silty clay up to 1.5" thick grades to bedrock with fine sand and layers of silty clay up to 1" thick; brown

FINE AND COARSE GRAVEL

SILTY/CLAYEY FINE TO COARSE SAND

tan

DESCRIPTION REMARKS

Ground Surface

SILTY CLAY

with fine sand; tan/brown

CLIENT: Case, Lowe & Hart, Inc.

PROJECT: Proposed Lucky Peak Warehouses

BORING LOG

Page: 1 of 1

W A

T E

R L

E V

E L

U S C S D

E P

T H

(F T

B L

O W

C O

U N

T

SA

M

P L

E S

Y M

B O

L

M O

IS

T

U R

E

D R

Y D

E N

SI

T

Y

P C

F

P

A

SS

IN

G

L

IQ

U

ID

L

IM

IT

P L

A

ST

IC

IT

Y I

N D

E X

50+

8.2

13.4

BORING: B-6

DATE STARTED: 10/12/23 DATE FINISHED: 10/12/23

LOCATION: 15169 East Highway 21, Boise, Idaho (43.5803°, -115.9897°) GSH FIELD REP.: TL

DRILLING METHOD/EQUIPMENT: 6-1/4" ID Hollow-Stem Auger HAMMER: Automatic WEIGHT: 140 lbs DROP: 30"

GROUNDWATER DEPTH: Not Encountered (10/12/23) ELEVATION: ---

CL slightly moist FILL medium stiff SM/ slightly moist SC medium dense very dense

SP/ moist SM medium dense

SM/ moist SC medium dense

See Subsurface Conditions section in the report for additional information. FIGURE 3F

End of Exploration at 16.5'.

No groundwater encountered at time of drilling.

SILTY FINE TO COARSE SAND

with some clay and trace fine gravel; brown

FINE TO COARSE SAND

with fine and coarse gravel and some silt; brown

SILTY/CLAYEY FINE TO COARSE SAND

with fine gravel; brown

DESCRIPTION REMARKS

Ground Surface

SILTY CLAY, FILL

with fine and coarse gravel and fine to coarse sand; brown

CLIENT: Case, Lowe & Hart, Inc.

PROJECT: Proposed Lucky Peak Warehouses

BORING LOG

Page: 1 of 1

W A

T E

R L

E V

E L

U S C S D

E P

T H

(F T

B L

O W

C O

U N

T

SA

M

P L

E S

Y M

B O

L

M O

IS

T

U R

E

D R

Y D

E N

SI

T

Y

P C

F

P

A

SS

IN

G

L

IQ

U

ID

L

IM

IT

P L

A

ST

IC

IT

Y I

N D

E X

50+

50+

16.2

14.1

BORING: B-7

DATE STARTED: 10/12/23 DATE FINISHED: 10/12/23

LOCATION: 15169 East Highway 21, Boise, Idaho (43.5803°, -115.9897°) GSH FIELD REP.: TL

DRILLING METHOD/EQUIPMENT: 6-1/4" ID Hollow-Stem Auger HAMMER: Automatic WEIGHT: 140 lbs DROP: 30"

GROUNDWATER DEPTH: Not Encountered (10/12/23) ELEVATION: ---

CL slightly moist medium stiff

See Subsurface Conditions section in the report for additional information. FIGURE 3G

No groundwater encountered at time of drilling.

End of Exploration at 5.0'.

DESCRIPTION REMARKS

Ground Surface

FINE TO MEDIUM SANDY CLAY

with silt; brown

CLIENT: Case, Lowe & Hart, Inc.

PROJECT: Proposed Lucky Peak Warehouses

BORING LOG

Page: 1 of 1

W A

T E

R L

E V

E L

U S C S D

E P

T H

(F T

B L

O W

C O

U N

T

SA

M

P L

E S

Y M

B O

L

M O

IS

T

U R

E

D R

Y D

E N

SI

T

Y

P C

F

P

A

SS

IN

G

L

IQ

U

ID

L

IM

IT

P L

A

ST

IC

IT

Y I

N D

E X

9.9

55.2

CLIENT: Case, Lowe & Hart, Inc.

PROJECT: Proposed Lucky Peak Warehouses

PROJECT NUMBER: 1019-044-23

① ② ③ ④

CEMENTATION: MODIFIERS:

Trace

<5%

Some

5-12%

With

> 12%

USCS STRATIFICATION:

SYMBOLS

Occasional:

One or less per 6" of thickness

Numerous;

More than one per 6" of thickness

Note: Dual Symbols are used to indicate borderline soil classifications.

⑤ ⑥ ⑦ ⑧ ⑨ ⑩ ⑪

COLUMN DESCRIPTIONS

① Water Level: Depth to measured groundwater table. See symbol below.

⑩ Liquid Limit (%): Water content at which a soil changes from plastic to liquid behavior.

② USCS: (Unified Soil Classification System) Description of soils encountered; typical symbols are explained below.

DESCRIPTION REMARKS

⑪ Plasticity Index (%): Range of water content at which a soil exhibits plastic properties.

③ Description: Description of material encountered; may include color, moisture, grain size, density/consistency, ⑫ Remarks: Comments and observations regarding drilling or sampling made by driller or field personnel. May include other field and laboratory test results using the following abbreviations:

④ Depth (ft.): Depth in feet below the ground surface.

⑤ Blow Count: Number of blows to advance sampler 12" beyond first 6", using a 140-lb hammer with 30" drop.

MOISTURE CONTENT (FIELD TEST):

Weakly: Crumbles or breaks with handling or slight finger pressure.

Dry: Absence of moisture, dusty, dry to the touch.

⑥ Sample Symbol: Type of soil sample collected at depth interval shown; sampler symbols are explained below. Moderately: Crumbles or breaks with considerable finger pressure.

Moist: Damp but no visible water.

⑦ Moisture (%): Water content of soil sample measured in laboratory; expressed as percentage of dryweight of Strongly: Will not crumble or break with finger pressure.

Saturated: Visible water, usually soil below water table.

⑧ Dry Density (pcf): The density of a soil measured in laboratory; expressed in pounds per cubic foot.

Descriptions and stratum lines are interpretive; field descriptions may have been modified to reflect lab test results. Descriptions on the logs apply only at the specific boring locations and at the time the borings were advanced; they are not warranted to be representative of subsurface conditions at other locations or times.

U N

IF

IE

D S

O

IL

C L

A S

S

IF

IC

A

T

IO

N S

Y S

T E

M

U S

C S

MAJOR DIVISIONS TYPICAL DESCRIPTIONS DESCRIPTION THICKNESS

COARSE-

GRAINED

SOILS

More than 50% of material is larger than No. 200 sieve size.

GRAVELS

More than 50% of coarse fraction retained on No. 4 sieve.

CLEAN

GRAVELS GW Well-Graded Gravels, Gravel-Sand Mixtures, Little or No Fines

(little or no fines)

Seam up to 1/8"

Layer 1/8" to 12"

(little or no fines) GP

Poorly-Graded Gravels, Gravel-Sand Mixtures, Little or No Fines

GRAVELS WITH

FINES GM Silty Gravels, Gravel-Sand-Silt Mixtures

Standard Penetration Split Spoon Sampler

(appreciable amount of fines) GC Clayey Gravels, Gravel-Sand-Clay Mixtures TYPICAL SAMPLER

SANDS

More than 50% of coarse fraction passing through No. 4 sieve.

CLEAN SANDS SW Well-Graded Sands, Gravelly Sands, Little or No Fines

GRAPHIC SYMBOLS

SILTS AND CLAYS Liquid Limit greater than

50%

MH Inorganic Silts, Micacious or Diatomacious Fine Sand or Silty Soils

California Sampler

SP Poorly-Graded Sands, Gravelly Sands, Little or No Fines Bulk/Bag Sample

SANDS WITH

FINES SM Silty Sands, Sand-Silt Mixtures

Peat, Humus, Swamp Soils with High Organic Contents

WATER SYMBOL

Water Level

Inorganic Clays of Low to Medium Plasticity, Gravelly Clays, Sandy Clays, Silty Clays, Lean Clays

FINE-

GRAINED

SOILS

More than 50% of material is smaller than No. 200 sieve size.

SILTS AND CLAYS Liquid Limit less than 50%

ML Inorganic Silts and Very Fine Sands, Rock Flour, Silty or Clayey Fine Sands or Clayey Silts with Slight Plasticity

No Recovery

CL

FIGURE 4

KEY TO BORING LOG

⑫

% Passing 200: Fines content of soils sample passing a No. 200 sieve; expressed as a percentage.

CH

(appreciable amount of fines) SC Clayey Sands, Sand-Clay Mixtures Rock Core

PT

⑨

Inorganic Clays of High Plasticity, Fat Clays Thin Wall

OH Organic Silts and Organic Clays of Medium to High Plasticity

HIGHLY ORGANIC SOILS

3.25" OD, 2.42" ID

D&M Sampler

OL Organic Silts and Organic Silty Clays o f Low Plasticity

3.0" OD, 2.42" ID

D&M Sampler

W A

T E

R L

E V

E L

U S C S D

E P

T H

(F T

B L

O W

C O

U N

T

S A

M P

L E

S Y

M B

O L

M O

IS

T

U R

E

D R

Y D

E N

S

IT

Y

P C

F

P

A S

S

IN

G

L

IQ

U

ID

L

IM

IT

P L

A S

T

IC

IT

Y

I N

D E

X

1019-044-23 Cov
1019-044-23 geo
1. INTRODUCTION
1.1 GENERAL
1.2 OBJECTIVES AND SCOPE
1.3 AUTHORIZATION
1.4 PROFESSIONAL STATEMENTS
2. PROPOSED CONSTRUCTION
3. SITE INVESTIGATIONS
3.1 GENERAL
3.2 FIELD PROGRAM
3.3 LABORATORY TESTING
3.3.1 General
3.3.2 Moisture and Density Tests
3.3.3 Partial Gradation Tests
3.3.4 Consolidation Tests
3.3.5 Chemical Tests
4. SITE CONDITIONS
4.1 SURFACE
4.2 SUBSURFACE SOIL
4.3 GROUNDWATER
5. DISCUSSIONS AND RECOMMENDATIONS
5.1 SUMMARY OF FINDINGS
5.2 EARTHWORK
5.2.1 Site Preparation
5.2.2 Temporary Excavations
5.2.3 Structural Fill
5.2.4 Fill Placement and Compaction
5.2.5 Utility Trenches
5.3 GROUNDWATER
5.3.1 Onsite Wastewater Percolation Test
5.4 SPREAD AND CONTINUOUS WALL FOUNDATIONS
5.4.1 Design Data
5.4.2 Installation
5.4.3 Settlements
5.5 LATERAL RESISTANCE
5.6 FLOOR SLABS
5.7 PAVEMENTS
5.8 CEMENT TYPES
5.9 GEOSEISMIC SETTING
5.9.1 General
5.9.2 Faulting
5.9.3 Site Class
5.9.4 Ground Motions
5.9.5 Liquefaction

5.10 SITE VISITS

6. CLOSURE

1019-044-23 Fig 1
1019-044-23 Fig 2
1019-044-23 B logs and key
1
2
3
4
5
6
7
k

File details come from the government source that posted it. Updated .