Bldg 17904 Inspection Report - Edited.pdf
PDF 5 MB Posted
- Attached to
- Repair Structural Fire Trainer B17903, 17904
- Solicitation number
- FA480126R0005
About this file
This document is a photographic inspection report of a federal facility, specifically a burn test structure or containment building. The images document extensive deterioration and maintenance deficiencies across multiple structural and operational systems requiring remediation.
The facility exhibits significant failing infrastructure including compromised interior and exterior metal liners with corrosion and separation at shutters, doorways, and burn cells throughout the structure. The corrugated metal ceiling shows substantial rust and deterioration with visible gaps and separations. Exterior wall panels display widespread rusting, discoloration, and material failure patterns. Interior burn cell walls show severe ash/residue staining and coating failure indicated by red arrows pointing to multiple degradation zones. The facility contains functional but aging electrical systems (panel box with yellow conduit visible), water delivery systems with brass fittings showing corrosion, and drainage infrastructure with visible rust and mineral deposits. Access doors and viewing windows are compromised with warped panels, cracked liners, and failed sealing mechanisms. Structural support elements including steel beams, railings, and hatch covers show significant corrosion and rust staining. The flooring system exhibits decay with damaged metal grating and deteriorated support members. One notation indicates electrical installation costs totaling $2,800.00. The overall condition assessment indicates the facility requires comprehensive rehabilitation of the liner system, structural components, mechanical systems, electrical infrastructure, and interior/exterior finishing to restore operational capability and maintain structural integrity.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment - FA480126R00050002.pdf | ||
| Solicitation Amendment FA480126R00050002 SF 30.pdf | ||
| SOW Rev 1 - Repair Bldgs 17903 17904 July 31 2026.pdf | ||
| Wall Picture 2.jpeg | JPEG file | |
| Wall Picture 4.jpeg | JPEG file | |
| WT 17518487 Questions.docx | DOCX document | |
| Wall Picture 1.jpeg | JPEG file | |
| Wall Picture 3.jpeg | JPEG file | |
| Answers.pdf | ||
| Solicitation Amendment - FA480126R00050001.pdf | ||
| Solicitation Amendment FA480126R00050001 SF 30.pdf | ||
| Site Visit QA Memorandum Amendment 01.pdf | ||
| As-Built Drawing 1.pdf | ||
| Solicitation - FA480126R0005.pdf | ||
| As-Built Drawing 2.pdf | ||
| SOW - Repair Bldgs 17903 and 17904.pdf | ||
| As-Built Drawing 3.pdf | ||
| Bldg 17903 Inspection Report - Edited.pdf | ||
| WT 17518487 AF Form 66.xlsx | XLSX spreadsheet | |
| Site Visit QA Memorandum.pdf |
Show all 20
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Failing liner and trims at shutters and doorways
Failing liner and trims in burn cells
I
Total installed $ 2800.00
File details come from the government source that posted it. Updated .