Bellevue_RC_100_Vol_II_F-SeriesDWGS_2021-02-25.pdf

PDF 3 MB Posted

Attached to
Construct Bellevue Readiness Center
Solicitation number
W9124321RCH02
Issued by

View the file

Other files

File Type Posted
BRC.Amendment.0003.pdf PDF
Amendment.0002.pdf PDF
Amendment.0001.pdf PDF
Bellevue_RC_100_Vol_II_E-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_I_L-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_I_A-Reference-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_I_S-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_I_A-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_II_T-SeriesDWGS_2021-02-25.pdf PDF
Exhibit G.subcontracting.plan.requirements.docx DOCX document
Bellevue_RC_100_Vol_I_C-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_II_M-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_I_G-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_SPEC_Vol_III_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_II_G-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_II_P-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_I_I-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_I_FFE-SeriesDWGS_2021-02-25.pdf PDF
EXHIBIT B.doc DOC document
EXHIBIT F.small.business.participation.plan.docx DOCX document
Exhibit D_Letter of Commitment.docx DOCX document
W9124321RCH02.pdf PDF
Bellevue_RC_100_SPEC_Vol_I_2021-02-25.pdf PDF
Bellevue_RC_100_Vol_I_FS-SeriesDWGS_2021-02-25.pdf PDF
Section.01000 General Requirements.pdf PDF
EXHIBIT A.doc DOC document
Bellevue_RC_100_Vol_II_RF-SeriesDWGS_2021-02-25.pdf PDF
Bellevue_RC_100_SPEC_Vol_II_2021-02-25.pdf PDF
EXHIBIT_C_Reference_Questionnaire_Package.docx DOCX document
Show all 29

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

FIRE ALARM / MNS / RELEASING SYSTEM LEGEND GENERAL NOTES:AUDIBLE DESIGN CRITERIA:

ABBREVIATIONS:

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AWG AMERICAN WIRE GAGE

CD CANDELA

CFM CUBIC FEET PER MINUTE

CIS COMMON INTELLIGIBILITY SCALE

CO CARBON MONOXIDE

DACT DIGITAL ALARM COMMUNICATOR TRANSMITTER

DB DECIBEL

DBA DECIBEL A-WEIGHTED

DDC DIRECT DIGITAL CONTROL

EMCS ENERGY MONITORING AND CONTROL SYSTEM

FA FIRE ALARM

FDC FIRE DEPARTMENT CONNECTION

FM FM GLOBAL

FX FIRE SUPPRESSION

HZ HERTZ

IAW IN ACCORDANCE WITH

IDC INITIATING DEVICE CIRCUIT

MNS MASS NOTIFICATION SYSTEM

NAC NOTIFICATION APPLIANCE CIRCUIT

NEC NATIONAL ELECTRICAL CODE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NC NORMALLY CLOSED

NO NORMALLY OPEN

RTS REMOTE TEST SWITCH

SLC SIGNALING LINE CIRCUIT

TYP TYPICAL

UL UNDERWRITERS LABORATORY

WP WEATHER PROOF (NEMA 250, TYPE 3R)

P = PHOTOELECTRIC

S = SUPPLY

S P

PHOTOELECTRIC SMOKE DETECTOR

S S

IN-DUCT PHOTOELECTRIC SMOKE DETECTOR

REMOTE INDICATOR

WF WATER FLOW DETECTOR / SWITCH (PROVIDED BY DIVISION 21)

F MANUAL FIRE ALARM PULL STATION

LOC LOCAL OPERATIONS CONSOLE

FAA FIRE ALARM ANNUNCIATOR

VS VALVE SUPERVISORY SWITCH (PROVIDED BY DIVISION 21)

SS

SURGE SUPPRESSOR

(TRANSIENT VOLTAGE SURGE SUPPRESSOR)

DH DOOR HOLD (PROVIDED BY DIVISION 08)

AMP AMPLIFIER

S SPEAKER

SPEAKER / STROBE COMBINATION

STROBE

WALL MOUNT STROBE

AOM ADDRESSABLE OUTPUT CONTROL MODULE

AIM ADDRESSABLE INPUT MONITOR MODULE

CO

CARBON MONOXIDE DETECTOR

RL NON-ADDRESSABLE OUTPUT RELAY

IM ISOLATION MODULE

BATT SECONDARY POWER SUPPLY (BATTERY)

GROUND

VISIBLE DESIGN CRITERIA:

FACU/ACU

COMBINATION FIRE ALARM CONTROL UNIT

AND AUTONOMOUS CONTROL UNIT

RTS

REMOTE TEST STATION

ST SHUNT TRIP BREAKER (BY DIVISION 26)

ESR ELEVATOR SYSTEM RECALL PANEL (BY DIVISION 14)

R = RED

NAC

NOTIFICATION CIRCUIT POWER BOOSTER,

EXTENDER PANEL

1. PROVIDE AUDIBLE NOTIFICATION APPLIANCES AS INDICATED TO

ACCOMPLISH THE FOLLOWING DESIGN CRITERIA WITH ALL DOORS, FIRE

SHUTTERS, AND WINDOWS CLOSED. WHERE THIS DESIGN CRITERIA IS

NOT ACCOMPLISHED DURING COMMISSIONING, PROVIDE ADDITIONAL

DEVICES TO MEET THE MINIMUM DESIGN CRITERIA WITHOUT EXCEEDING

THE LIMITATIONS OF THE FACU, NAC, OR AMP. (INCLUSIVE OF PRESCRIBED

SAFETY FACTORS).

2. PROVIDE A QUANTITY OF SPEAKERS IN EACH ROOM/AREA TO ACHIEVE THE

REQUIRED SOUND POWER AND INTELLIGIBILITY OUTLINED IN THESE

CONTRACT DOCUMENTS. NOTE: DEPENDING ON THE QUALITY OF SPEAKER

USED, SEVERAL SPEAKERS TAPPED AT A LOWER SETTING MAY BE

REQUIRED TO ACHIEVE THE PRESCRIPTIVE CIS SCORE.

3. PROVIDE A MINIMUM SOUND POWER OF 70 DBA AND 15 DBA OVER THE

AVERAGE AMBIENT SOUND LEVEL AT THE MOST REMOTE LOCATION WITHIN

THE ROOM/AREA MEASURED AT 5 FT AFF. MEASURE THE SOUND POWER

OFF THE TEMPORAL THREE TONE PATTERN. THE FOLLOWING CRITERIA

WILL BE USED FOR REVIEW AND APPROVAL OF SHOP DRAWINGS.

A. REDUCE THE SOUND POWER BY 6 DB EACH TIME THE DISTANCE

BETWEEN THE APPLIANCE AND THE LISTENER IS DOUBLED.

STARTING DISTANCE IS PER MANUFACTURER'S DATASHEET,

TYPICALLY 10 FT.

B. REDUCE THE SOUND POWER IN ACCORDANCE WITH THE

MANUFACTURER'S DATASHEET FOR SOUND POWER DISTRIBUTION

NOT PERPENDICULAR TO THE FACE OF THE APPLIANCE. REFER TO

MANUFACTURER'S TYPICAL SOUND OUTPUT DISTRIBUTION DIAGRAM.

C. IN LIEU OF THE MANUFACTURER'S PUBLISHED DB LOSS, ASSUME A

MINIMUM 15 DB LOSS THROUGH A STANDARD CLOSED DOOR.

4. PROVIDE EXTERIOR SPEAKERS MEETING A MINIMUM SOUND POWER OF 70

DBA AND 15 DBA OVER THE AVERAGE AMBIENT SOUND LEVEL, AND A CIS OF

0.8 WITHIN THE AREA INDICATED MEASURED AT 5 FT ABOVE GRADE.

MEASURE THE SOUND POWER OFF THE TEMPORAL THREE TONE PATTERN.

THE AVERAGE AMBIENT SOUND LEVEL IS THE ROOT MEAN SQUARE, A-

WEIGHTED, SOUND PRESSURE LEVEL MEASURED OVER THE DURATION THE

BUILDING IS NORMALLY OCCUPIED.

5. MEET THE FOLLOWING INTELLIGIBILITY CRITERIA:

A. ACHIEVE A CIS SCORE OF 0.8 IN EACH ROOM MEASURED AT 5 FT AFF.

B. A LESSER CIS IS PERMITTED IN AREAS OF THE BUILDING WITH

EXCESSIVE SOUND REFLECTIONS, SUCH AS ROOMS WITH HARD

SURFACES (METAL, TILE, OR CONCRETE), WHERE THE OCCUPANT

CAN WALK NO MORE THAN 33 FT TO A LOCATION THAT ACHIEVES THE

MINIMUM CIS. THIS AREA MUST BE READILY ACCESSIBLE, WITHOUT

REQUIRING THE OCCUPANT TO WALK THROUGH A SECURED

DOOR/AREA OR EXIT THE BUILDING.

C. A LESSER CIS IS PERMITTED IN A NORMALLY UNOCCUPIED ROOM OF

THE BUILDING, WHERE THE OCCUPANT CAN WALK NO MORE THAN 50

FT TO A LOCATION THAT ACHIEVES THE MINIMUM CIS. THIS AREA

MUST BE READILY ACCESSIBLE, WITHOUT REQUIRING THE OCCUPANT

TO WALK THROUGH A SECURED DOOR/AREA OR EXIT THE BUILDING.

NORMALLY UNOCCUPIED ROOMS ARE CONSIDERED TO BE STORAGE

ROOMS < 100 SF, MECHANICAL / ELECTRICAL ROOMS,

COMMUNICATION CLOSETS, AND FIRE PROTECTION ROOMS.

1. PROVIDE VISIBLE NOTIFICATION APPLIANCES AS REQUIRED TO ACHIEVE

THE COVERAGE INDICATED.

2. SPACE STROBES IN ACCORDANCE WITH THE CRITERIA OUTLINED IN NFPA

72, UNLESS OTHERWISE NOTED.

1. PROVIDE AN ADDRESSABLE COMBINED FIRE ALARM / MASS

NOTIFICATION SYSTEM. INCLUDE CAPABILITY TO USE FIRE ALARM

SPEAKERS FOR PA ANNOUNCEMENTS AS INDICATED.

2. COORDINATE ALL REQUIRED SYSTEMS TO THE SATISFACTION OF THE

ENGINEER AND AUTHORITY HAVING JURISDICTION. ANY DEFICIENCIES,

INCONSISTENCIES, OR POORLY COORDINATED INSTALLATIONS SHALL BE

CORRECTED BY THE CONTRACTOR AT NO ADDITIONAL COST.

3. THE FIRE ALARM DRAWINGS ARE SCHEMATIC IN NATURE AND SHOW A

MINIMAL QUANTITY OF DEVICES. DETERMINE THE FINAL QUANTITY AND

LOCATION OF ALL DEVICES IN ACCORDANCE WITH THE SPECIFICATIONS,

CONTRACT DRAWINGS, AND MANUFACTURER'S WRITTEN

RECOMMENDATIONS TO BE COMPLIANT WITH ALL APPLICABLE CODES

AND STANDARDS. PROVIDE ADDITIONAL DEVICES WHEN REQUIRED FOR

A FULLY FUNCTIONING FIRE ALARM SYSTEM AND MASS NOTIFICATION AS

REQUIRED BY NFPA 72, UFC 3-600-01 AND UFC 4-021-01.

4. CONCEAL ALL CONDUITS IN WALLS OR ABOVE CEILINGS UNLESS

OTHERWISE INDICATED. EXCEPTION: CONDUIT IS ALLOWED TO BE

SURFACE MOUNTED ON WALLS AND CEILINGS IN UNFINISHED AREAS

(SUCH AS MECHANICAL ROOM, ELECTRICAL ROOM, FIRE PROTECTION

ROOM). WHERE A CONDUIT SUPPLIES A DEVICE NOT MOUNTED DIRECTLY

ON THE WALL OR CEILING, ROUTE THE CONDUIT AS A SINGLE PENDENT

DROP TO EACH DEVICE FROM THE CEILING SURFACE ABOVE. DO NOT

TRAPEZE CONDUIT ACROSS AN OPEN SPACE.

5. ALL EXPOSED FIRE ALARM JUNCTION BOXES, COVERS AND CONDUITS IN

UNFINISHED AREAS ARE TO BE PROVIDED PRE-FINISHED RED FROM THE

FACTORY. PAINT EXPOSED CONDUIT AND JUNCTION BOXES IN FINISHED

AREAS TO MATCH ADJACENT SURFACES. FOR FINISHED AREAS WITH

EXPOSED CONDUIT AND BOXES TO MATCH ADJACENT SURFACES, LABEL

INSIDE COVER OF JUNCTION BOXES "FIRE ALARM", AND INSTALL 3/4"

WIDE RED BANDS ON CONDUIT EVERY 20FT AND ON BOTH SIDES OF

WALL PENETRATIONS PER UFC 3-600-01.

6. PROVIDE CONDUIT IN ACCORDANCE WITH THE REQUIREMENTS OF THE

ELECTRICAL SPECIFICATIONS, UNLESS OTHERWISE NOTED. SUPPORT

CONDUIT IN ACCORDANCE WITH THE NEC SUCH AS MAXIMUM 10 FT

SUPPORT INTERVALS AND 3 FT FROM A TERMINATION. TENSION ONLY

HANGERS ARE NOT PERMITTED SUCH AS BATWINGS. FLEXIBLE CONDUIT

IS ONLY PERMITTED WHEN CONNECTING TO THE FOLLOWING DEVICES

AND APPLIANCES: DEVICES LOCATED ON FIRE SUPPRESSION

EQUIPMENT SUCH AS FLOW/PRESSURE SWITCHES AND TAMPER

SWITCHES, DEVICES AND APPLIANCES LOCATED IN REMOVABLE CEILING

TILES, OR DUCT DETECTORS.

7. PROVIDE CONDUCTOR SIZING NOT LESS THAN 18 AWG FOR SLC.

PROVIDE CONDUCTOR SIZING NOT LESS THAN 16 AWG FOR NAC AND

IDC. PER UFC 3-600-01 CONSISTENTLY COLOR COORDINATE ALL

CONDUCTORS THROUGH THE SYSTEM IN RELATION TO DEVICES THEY

FEED SUCH AS SLC - BLACK/RED, STROBE - YELLOW/BLUE. PROVIDE

ADDRESSABLE SLC CIRCUITS WITH SHIELDED CONDUCTORS, WHERE

THE SHIELDING IS GROUNDED AT ONE END. PROVIDE ALL CIRCUITS WITH

LABELING AT THE POINT OF TERMINATION SUCH AS SLC 1, NAC 8, IDC 4.

8. RUN CONDUCTORS FROM DEVICE TO DEVICE WITHOUT SPLICES. WIRE

NUTS ARE PROHIBITED. UTILIZE TERMINAL STRIPS WHERE

CONDUCTORS CANNOT BE DIRECTLY TERMINATED AT THE DEVICE SUCH

AS PIGTAILS OFF A HEAT DETECTOR.

9. DO NOT USE FIRE ALARM EQUIPMENT PANELS AS RACEWAY FOR

ROUTING POWER WIRING OR LOW VOLTAGE WIRING. ONLY ROUTE

WIRING TERMINATING WITHIN THE PANEL INTO THE PANEL. PROVIDE 1/4

INCH SEPARATION BETWEEN POWER-LIMITED FIRE ALARM CIRCUITS AND

POWER CIRCUITS.

10. MOUNTING DEVICES IN THE FACU, INCLUDING ANY SUBPANELS SUCH AS

ACU, AMP AND NAC, WHICH ARE NOT UL LISTED OR FM APPROVED AS

PART OF THE UNIT IS PROHIBITED.

11. PROVIDE SURGE SUPPRESSORS TO PROTECT ALL POWER SUPPLY

CIRCUITS TO THE FACU, INCLUDING ANY SUBPANELS SUCH AS ACU, AMP,

NAC, AND ALL FIRE ALARM CIRCUITS LEAVING OR ENTERING THE

BUILDING. DEVICES AND APPLIANCES MOUNTED DIRECTLY ON THE

EXTERIOR OF THE BUILDING SUCH AS WALL MOUNTED EXTERIOR

SPEAKERS DO NOT REQUIRE SUPPRESSORS WHEN LIGHTNING

PROTECTION IS PROVIDED. MOUNT SURGE SUPPRESSORS IN A

SEPARATE ENCLOSURE, UNLESS IT IS UL LISTED OR FM APPROVED AND

INSTALLED IN THE CONTROL UNIT BY THE FACTORY.

12. INSTALL FIRE ALARM BATTERIES IN THE ENCLOSURE OF THE

DEVICE/UNIT IT SUPPORTS SUCH AS FACU ENCLOSURE OR IN AN

INDEPENDENT DEDICATED ENCLOSURE.

WC WET CHEMICAL SYSTEM

HORN / STROBE COMBINATION

WC WET CHEMICAL SYSTEM REMOTE PULL STATION (WC)

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o n e

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:5

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FA001

FIRE ALARM

NOTES, LEGEND

AND

ABBREVIATIONS

18-0060

02-25-2021

C. QUINN

C. CARRAS

Revisions

ID Date Description

11/17/2020 02/25/2021

PROVIDE CEILING MOUNTED SPEAKERS AND CLEAR STROBES

AS REQUIRED TO ACHIEVE DESIGN CRITERIA.

PROVIDE CEILING MOUNTED SPEAKERS AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE NOT REQUIRED .

PROVIDE WEATHERPROOF WALL MOUNTED SPEAKERS, AS

REQUIRED TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

PROVIDE WEATHERPROOF WALL MOUNTED SPEAKERS AND

STROBES TO ACHEIVE THE DESIGN CRITERIA.

F

S P

F

S P

F

F

F

F

CO

LOC

LOC

F

F

S P

A

B

C

E

F

G

H

L

N

P

Q

7.6 8.6 9.2 9.8 10.6 10.8 11.6

6.7

7.7

8.7 9.7

10.5

11 12

CORR

RECEIVING

ELEV EQUIP

CST STORAGE

STAIR

CONF

C S

T L

O G

A

D M

IN

A

MECH

ELEC

GROUNDS &

MAINTENANCE

FLAMMABLE

STORAGE

IT

CST READY

BAYS

CUST

TOILET

TOILET

OFFICE

36A

CST SURVEY

CST COMMO

OFFICE

29A

CST MED

SUPPORT

OFFICE

28A

CST MED STOR

36B

IT

ELEC

CST

OPERATIONS

OFFICE

29B

OFFICE

28B

CST COMMAND

OFFICE

28C

MECH

TRAINING AID

STORAGE

29C

PLUMBING

CHASE

30E

CORRIDOR

7B CORR

STAIR

F

F

F

AMP

NAC

AMP NAC

S P

VS

VSWF

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F'

'D'

'B'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:5

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FA101-1A

FIRE ALARM AND

MNS PLAN -

LOWER LEVEL -

OVERALL

18-0060

02-25-2021

C. QUINN

C. CARRAS

NOTES:

REFER TO FA001 FOR GENERAL NOTES, DESIGN CRITERIA,

ABBREVIATIONS AND SYMBOLS.

WALL MOUNTED NOTIFICATION DEVICES ARE PERMITTED IN UNFINISHED

AREAS WITH CONGESTED CEILINGS SUCH AS A MECHANICAL ROOM.

REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING

PLANS.

1/16" = 1'-0"

FIRE ALARM AND MNS PLAN - LOWER LEVEL - OVERALL

1.

2.

3.

SCALE IN FEET

0 8' 16' 32'

KEYED NOTES

1 PROVIDE RECESSED PANEL.

2 REFER TO FIRE SUPPRESSION DRAWINGS FOR QUANTITY AND /

OR LOCATIONS OF DEVICE(S).

3 MANUAL PULL STATION AND EXTERIOR SPEAKER

REQUIREMENTS ARE NOT REQUIRED AS PART OF OPTION 1.

REFER TO FA901-1F.

Revisions

ID Date Description

11/17/202002/25/2021

F

S P

FAA

F

CO

F

CO

LOC

LOC

WC

F

N A

C A

M P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

S P

C

E

F

G

H

J

K

L

M

N

N.5

P

Q

R

2.6 3.6 4.8 5.4 7.6 8.6 9.8 10.6 10.8 11.6

3.5

4 5

5.1

5.9

6.7

7.7

8.7 9.7

10.5

11 12

ASSEMBLY

CLASSROOM/

LECTURE

FAMILY

READINESS

RECRUITING

LEARNING

CENTER

DISPLAY

101A

L A

C T

A T

IO

N

LOCKERS

CLASSROOM

BREAK /

VENDING

CLASSROOM

TRAINING

VEST

MECH / WATER

SERVICE

ANTE

105A

ANTE

105B

PHYSICAL

FITNESS

MEN

110WOMEN

ISSUING

BEVERAGES

158B

MEDICAL

TABLE / CHAIR

STORAGE

104A

KITCHEN

SERVING

158A

LOBBY / MAIN

HALL

CORR

CORR

ELEC

IT

VAULT

153A

ARMORER

ISSUING

ISSUING

152.1

WOMEN

LOCKERS

108A

MEN LOCKERS

110A

MECH

ELEC

CUST

IT

PANTRY /

OFFICE

160D

CUST

160C

TOILET

160B

SCULLERY

160A

CORR

157B

CORR

157A

CORR

CORR

101C

ALCOVE

101B

ALCOVE

101D

MEN SHOWERS

110BWOMEN

SHOWERS

108B

TOILET

CONF

OFFICE

OFFICE

WORK RM

OPEN OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONF

OFFICE

OFFICE

MECH

WORK RM

OPEN OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

PLUMBING

CHASE

109C

PLUMBING

CHASE

111C

ISSUING

157E

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORR

101E

ELEV LOBBY /

STAIR

101F

HEATED

STORAGE

VS

WP

DHDH

DH

DH

DH

DH

DH

3 3

DH

DH

WC

DH

WF

PROVIDE CEILING MOUNTED SPEAKERS AND CLEAR STROBES

AS REQUIRED TO ACHIEVE DESIGN CRITERIA.

PROVIDE CEILING MOUNTED SPEAKERS AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE NOT REQUIRED .

PROVIDE WEATHERPROOF WALL MOUNTED SPEAKERS, AS

REQUIRED TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

PROVIDE WEATHERPROOF WALL MOUNTED SPEAKERS AND

STROBES TO ACHEIVE THE DESIGN CRITERIA.

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F''E'

'C' 'D'

'B' 'A'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FA101-2A

FIRE ALARM AND

MNS PLAN - MAIN

LEVEL - AREA A,

B, C & D

18-0060

02-25-2021

C. QUINN

C. CARRAS

1/16" = 1'-0"

FIRE ALARM AND MNS PLAN - MAIN LEVEL - AREA A, B, C & D

SCALE IN FEET

0 8' 16' 32'

NOTES:

REFER TO FA001 FOR GENERAL NOTES, DESIGN CRITERIA,

ABBREVIATIONS AND SYMBOLS.

WALL MOUNTED NOTIFICATION DEVICES ARE PERMITTED IN UNFINISHED

AREAS WITH CONGESTED CEILINGS SUCH AS A MECHANICAL ROOM AND

HIGH-CEILING AREAS SUCH AS MAIN HALL AND ASSEMBLY.

REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING

PLANS.

1.

2.

3.

1 / FA101 - 2E

KEYED NOTES

1 EXTERIOR WP HORN STROBE OVER FDC.

2 PROVIDE RECESSED PANEL.

3 PROVIDE OUTPUT MODULE AND 24V POWER FOR MAGNETIC DOOR

HOLD OPEN DEVICES. REFER TO ARCHITECTURE DRAWING A-601

FOR DOOR HARDWARE INFORMATION.

4 PROVIDE 4" OCTOGONAL BOX FOR THE MANUAL PULL STATION

WHERE SHOWN ON THE PLANS AT 48" AFF. THE BOX SHALL HAVE

THE DEVICE MOUNTING SCREWS AT THE 2 AND 8 O'CLOCK

POSITIONS, AND 1/2" DIAMETER CONDUIT STUBBED STRAIGHT UP

TO 6" ABOVE THE FINISHED CEILING. NO BENDS OR ELBOWS ARE

PERMITTED IN THIS CONDUIT.

5 REFER TO FIRE SUPPRESSION DRAWINGS FOR QUANTITIES AND

LOCATIONS.

Revisions

ID Date Description

P

N A

C

A M

P

F A

B

C

2.6 3.6 4.8 5.4 7.6 8.6 9.2 9.8 10.6 10.8 11.6

LOCKERS

ELEC

157D

IT

157C

CONF

MECH

HEATED

STORAGE

CORR

OPEN OFFICE

F FF

F A

C U

A C

U

L O

C

PROVIDE CEILING MOUNTED SPEAKERS AND CLEAR STROBES

AS REQUIRED TO ACHIEVE DESIGN CRITERIA.

PROVIDE CEILING MOUNTED SPEAKERS AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE NOT REQUIRED .

PROVIDE WEATHERPROOF WALL MOUNTED SPEAKERS, AS

REQUIRED TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

PROVIDE WEATHERPROOF WALL MOUNTED SPEAKERS AND

STROBES TO ACHEIVE THE DESIGN CRITERIA.

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F''E'

'C' 'D'

'B' 'A'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FA101-2E

FIRE ALARM AND

MNS PLAN - MAIN

LEVEL - AREA E &

F

18-0060

02-25-2021

C. QUINN

C. CARRAS

1/16" = 1'-0"

FIRE ALARM AND MNS PLAN - MAIN LEVEL - AREA E & F

NOTES:

REFER TO FA001 FOR GENERAL NOTES, DESIGN CRITERIA,

ABBREVIATIONS AND SYMBOLS.

WALL MOUNTED NOTIFICATION DEVICES ARE PERMITTED IN UNFINISHED

AREAS WITH CONGESTED CEILINGS SUCH AS A PUMP ROOM OR

MECHANICAL ROOM.

REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING

PLANS.

1.

2.

3.

SCALE IN FEET

0 8' 16' 32'

1 / FA101 - 2A

KEYED NOTES

1 PROVIDE RECESSED PANEL.

Revisions

5 FT (MIN)

12 INCHES

(MAX)FOR CEILING HEIGHTS LESS

THAN 96 INCHES THE VISIBLE

LENS MOUNTING HEIGHT

SHALL BE WITHIN 6 INCHES

OF THE CEILING

TO EXIT DOOR

5 FT (MAX)

INCHES

MAX

SYNCHRONIZE TWO

OR MORE

APPLIANCES IN ANY

FIELD OF VIEW

I

N C

H E

S

WALL MOUNTED

SMOKE DETECTOR

CEILING MOUNTED

SMOKE DETECTOR

SUPPLY OR

RETURN

DIFFUSER

CEILING

FINISHED FLOOR

WALL

MOUNTED

VISIBLE

APPLIANCE

MINIMUM 12 INCHES

FROM LIGHT SWITCH

(TYPICAL FOR FOAM

APPLIANCES)

PULL STATIONS SHALL NOT BE

LOCATED BEHIND DOOR SWINGS.

MAXIMUM DISTANCE BETWEEN SPEAKERS

SHALL NOT EXCEED 30 FEET,

UNLESS OTHERWISE NOTED.

DO NOT EXCEED A DISTANCE

OF 20 FEET, UNLESS

OTHERWISE NOTED.

60 INCHES

TO TOP

BATT BATT

NAC

NAC

AMP

AMP

BATT

FACU/

ACU

ROUTE CONDUIT TO ACHIEVE

SEPARATION OF POWER-

LIMITED FIRE ALARM CIRCUITS

AND POWER CIRCUITS

IN

S

T A

L L N

O G

R E

A T

E R

T

H A

N

I

N C

H E

S A

F F

DACT

F

FAA LOC

SS SS

CEILING MOUNTED

VISIBLE APPLIANCE

AUDIBLE

ONLY

WALL

MOUNTED

APPLIANCE

5 FT (MIN)

CARBON MONOXIDE

DETECTOR

WALL MOUNTED MAGNETIC

DOOR HOLDER. REFER TO ARCHITECTURAL

DRAWINGS FOR LOCATIONS.

WALL MOUNTED MAGNETIC

DOOR HOLDER. REFER TO ARCHITECTURAL

DRAWINGS FOR LOCATIONS.

FACU / ACU

FIRE ALARM

DEVICES

LOWER LEVER

MAIN LEVEL

IM IM

FIRE ALARM

DEVICES

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FA501

FIRE ALARM

DETAILS

18-0060

02-25-2021

C. QUINN

C. CARRAS

NTS

TYPICAL MOUNTING DETAIL

NTS

CLASS B ISOLATION MODULE MOUNTING

Revisions

ID Date Description

FACU / ACU

NOTES:

KEYED NOTES:

S P

VS WF

F

BATT

SS

120 VAC

S

SS

NAC

BATT

SS

120 VAC

AMP

S

WP

2 2

CO

AOM

AOMS

S

RTS

RL

24 V FROM

VFD/STARTER

TO ENABLE

INPUT ON

VFD/STARTER

POWER CIRCUIT

VISIBLE NOTIFICATION APPLIANCE CIRCUIT (CLASS B)

AUDIBLE NOTIFICATION APPLIANCE CIRCUIT (CLASS B)

SIGNALING LINE CIRCUIT (CLASS B)

AIM

AIMAIMAIM

120 VAC 1 BATT

CIRCUIT LEGEND:

SYNCHRONIZATION

CIRCUIT TO NEXT NAC

PANEL

WP

INITIATING DEVICE CIRCUITS

WF 11

ST

AOM

RL

AIM

-120 VAC

RL

AIM

TO

PROTECTED

DEVICE

ESR

+120 VAC

FAA

LOC

1. REFER TO FA001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS, AND SYMBOLS.

2. THE FIRE ALARM RISER SHOWS THE INTENT OF THE

FIRE ALARM INFRASTRUCTURE. NOT ALL DEVICES

ARE SHOWN. CONTRACTOR SHALL PROVIDE THE

QUANTITY OF DEVICES AS REQUIRED TO COMPLY

WITH NFPA 72, UFC 3-600-01,UFC 4-021-01 AND

CONTRACT DOCUMENTS.

3. EACH FLOW AND TAMPER SWITCH SHALL REPORT

BACK TO THE FIRE ALARM CONTROL PANEL WITH A

SEPARATE ADDRESS. GROUPED SWITCHES ON ONE

ADDRESS ARE NOT ACCEPTABLE.

RED, LOCKABLE BREAKER LABELED "FIRE ALARM"

PROVIDED BY DIVISION 26. SEE ELECTRICAL PLANS

FOR ADDITIONAL INFORMATION.

QUANTITY AND LOCATION BY CONTRACTOR'S

DESIGN TO MEET DESIGN CRITERIA.

REFER TO FIRE SUPPRESSION DRAWINGS FOR

QUANTITY AND / OR LOCATIONS OF DEVICE(S).

REFER TO FIRE ALARM PLANS FOR QUANTITY AND /

OR LOCATIONS OF DEVICE(S).

PROVIDE ADDRESSABLE INPUT AND/OR OUTPUT

MODULE(S) AS REQUIRED TO ACHIEVE THE

FUNCTIONALITY INDICATED IN THE FIRE ALARM

MATRIX.

PROVIDE ADDITIONAL BOOSTER PANELS AS

REQUIRED PER CONTRACTOR'S DESIGN. WHERE

ADDITIONAL BOOSTER PANELS ARE REQUIRED,

LOCATE AS INDICATED ON PLAN.

PROVIDE ADDITIONAL AMPLIFIERS AS REQUIRED PER

CONTRACTOR'S DESIGN. WHERE ADDITIONAL

AMPLIFIERS ARE REQUIRED, LOCATE AS INDICATED

ON PLAN.

PROVIDE SUPPLY AND RETURN DUCT SMOKE

DETECTORS FOR DIRECT SHUT DOWN FOR THE

FOLLOWING UNITS: AHU-101, AHU-102, AHU-201,

AHU-203, AHU-204, AHU-205, AHU-206, AHU-207,

AUH-208, MAU-101, MAU-102, ERU-202, SHUTDOWN

THROUGH THE EMCS/DDC IS NOT PERMITTED.

REFERENCE MECHANICAL DRAWINGS FOR EXACT

LOCATION.

EXTERIOR WP HORN STROBE OVER FDC.

EXTERIOR WP FIRE ALARM / MASS NOTIFICATION

SPEAKERS.

24 VDC TO FACU OR NAC PANEL.

RELAY TO MONITOR INTEGRITY OF POWER SUPPLY.

RELAY TO ENABLE 120 VAC TO SHUNT TRIP

BREAKER.

ELEVATOR SHUNT TRIP BREAKER (BY DIVISION 26).

REFER TO ELECTRICAL DRAWINGS FOR LOCATIONS.

PROVIDE INDICATING LIGHT AND SIGN NEAR HVAC

UNIT MODULE ON SMOKE DETECTION WHERE

INDICATING LIGHT ON THE SMOKE DETECTOR IS NOT

VISIBLE FROM FLOOR.

DESTRATIFICATION FAN SHUNT TRIP

(BY DIVISION 26). REFER TO ELECTRICAL DRAWINGS

FOR LOCATIONS.

PUBLIC ADDRESS PAGING INPUT. REFER TO T-403

FOR VOIP DEVICE AND ASSOCIATED ANALOG INPUT.

EXTERIOR WEATHER PROOF SPEAKER/STROBE

PROVIDED FOR ROOF TERRACE NOTIIFICATION.

EGRESS LIGHTING TO ACTIVATE UPON ACTIVATION

OF FIRE ALARM. REFER TO LIGHTING CONTROLS

MATRIX ON ELECTRICAL DRAWING E-711 FOR

REQUIRED LOCATIONS.

WF 11

STRL

AIM

-120 VAC

RL

AIM

TO

DESTRATIFICATION

FAN CONTROL

+120 VAC

LOWER LEVEL

UPPER LEVEL

MAIN LEVEL

MAIN LEVEL

S P

F

BATT

SS

120 VAC

S

NAC

BATT

SS

120 VAC

AMP

S WP

2 2

CO

AOM

AOMS

S/R

RTS

RL

24 V FROM

VFD/STARTER

TO ENABLE

INPUT ON

VFD/STARTER

AIM

AIM

15 11

SYNCHRONIZATION

CIRCUIT TO NEXT NAC

PANEL

PA 17DACT

AOM

EGRESS LIGHTING

SYSTEM

AIM

WC

AOM

DH

5 11

WP

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FA601

FIRE ALARM

ONE-LINE

DIAGRAM

18-0060

02-25-2021

C. QUINN

C. CARRAS

Revisions

FIRE ALARM CONTROL UNIT (FACU) FUNCTIONAL MATRIX

ANNUNCIATION AT

LOCAL PANEL

NOTIFICATION AUXILIARY

FUNCTION

A U

D

IO

-V

IS

IB

L E

F

IR

E A

L A

M

IN

D

IC

A T

IO

N

B Y

D E

V

IC

E

A U

D

IO

-V

IS

IB

L E

T R

O U

B L E

I N

D

IC

A T

IO

N

B

Y D

E V

IC

E

A U

D

IO

-V

IS

IB

L E

S U

P E

R V

IS

O

IC

A T

IO

N

B Y

D E

V

IC

E

M A

N U

A L P

U L L S

T A

T

IO

N A

L A

R M

S

IG

N A

L

O

C E

N T

R A

L S

T A

T

IO

C

M M

O N

T R

O U

B L E

S

IG

N A

L

C

N T

R A

L S

T A

T

IO

N

C O

M M

O N

S U

P E

R V

IS

O

R Y

S

IG

N

C E

N T

R A

L S

T A

T

IO

N

S H

U T

-D O

W N

A S

S O

C

IA

T E

D

IR

N D

L

IN

G E

Q U

IP

M

E N

T

E L E

V A

T O

R R

E C

A L L T

O P

R

IM

A

C A

L L F

L O

O R

E L E

V A

T O

R R

E C

A L L T

O S

E C

O N

D A

C

A L L F

L O

O R

IN

IT

IA

T

E E

L E

V A

T O

R S

H U

N T

T

IP

ALARM SIGNALS

MANUAL FIRE ALARM STATIONS

SMOKE DETECTOR OVER FACU, AMPS AND NAC PANELS

FLOW SWITCHES - WET-PIPE SYSTEM

SMOKE DETECTION - ELEVATOR MAIN FLOOR LOBBY

SMOKE DETECTION - ELEVATOR LOWER LEVEL

SMOKE DETECTION - ELEVATOR EQUIPMENT ROOM

AC POWER FAILURE

LOW BATTERY

OPEN CIRCUIT FAULT

GROUND FAULT

NOTIFICATION APPLIANCE CIRCUIT SHORT

TROUBLE SIGNALS

COMPONENT COMMON TROUBLE

SUPERVISORY SIGNALS

COMPONENT COMMON SUPERVISORY

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

F

IR

E A

L A

R M

/M N

S V

IS

IB

T

IF

IC

A T

IO

N

M A

S S

N O

T

IF

IC

A

T

IO

N O

V E

R R

ID

E

S

IG

N

F

IR

E S

Y S

T E

M C

O N

T R

O L P

A N

E L

M A

S S

N O

T

IF

IC

A

T

IO

N A

N N

O U

N C

E M

E N

T

F

IR

E A

L A

R M

A U

D

IB

L E

N O

T

IF

IC

A

T

IO

N

S

IL

E N

C E

G E

N E

R A

L F

IR

E

A L A

N

O U

N C

E M

E N

T

X

X

X

X

X

X

KITCHEN HOOD SUPPRESSION X

X

X

X

X

X

X

D

IS

A B

L E

P U

B L

IC

A D

D R

E S

S S

Y S

T E

M

X

X

X

X

X

X

IN-DUCT SMOKE DETECTORS XX X X

XMASS NOTIFICATION INPUT (LOCAL) XX X X X

GENERAL VALVE SUPERVISORY X X

IN

IT

IA

T

E D

E S

T R

A T

IF

IC

A T

IO

N

F

U N

T T

R

IP

X

IN

IT

IA

T

E F

L A

S H

IN

G

R E

D H

A T

S

IG

N

L E

V A

T O

R

IN

IT

IA

T

E S

O L

ID

S T

A T

E R

E D

H

IG

N A

L I

N E

L E

V A

T O

R

X

X

X S

M O

K E

D E

T E

C T

IO

N

A L A

R M

S

IG

N

C E

N T

R A

L S

T A

T

IO

N

X

X

X

X

F

IR

E S

U P

P R

E S

S

IO

N A

C T

IV

A

T

IO

N A

L A

N

A L T

O C

E N

T R

A L S

T A

T

IO

N

C A

R B

O N

M O

N O

X

ID

E A

L A

R M

S

IG

N A

L T

O C

E N

T R

A L S

T A

T

IO

N

X

XCARBON MONOXIDE DETECTORS X

XXX

P U

B L

IC

A D

D R

E S

S A

N N

O U

N C

E M

E N

T O

V

F

IR

E A

L A

R M

M

N S

S P

E A

K E

R S

PUBLIC ADDRESS PAGING VIA VOIP PHONE SYSTEM X

X

R E

L E

A S

E H

O L D

-O P

E N

D E

V

IC

E

O R

S

C A

R B

O N

M O

N

IX

ID

E

A N

N O

U N

C E

M E

N T

X

FLOW SWITCHES - ELEVATOR EQUIPMENT ROOM X

SMOKE DETECTORS - FIRE DOOR HOLD - OPEN XX X X X X

X X

X

X

A C

T

IV

A T

E E

M E

R G

E N

C Y

E G

R E

H T

IN

G

X

X

X

X

X

X

X

X

MASS NOTIFICATION MESSAGES SHALL BE A FEMALE

VOICE AND STATE THE FOLLOWING. MASS NOTIFICATION MESSAGES ARE

LISTED IN ORDER OF PRIORITY. COORDINATE FINAL MESSAGES WITH BASE.

1. (TEMPORAL THREE ALERT TONE)

<TWO ROUNDS>

"MAY I HAVE YOUR ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION

PLEASE. A FIRE EMERGENCY HAS OCCURRED; PLEASE LEAVE THE

BUILDING BY THE NEAREST EXIT DO NOT USE THE ELEVATORS."

<PAUSE 2 SECONDS> REPEAT MESSAGE.

2. (TEMPORAL FOUR ALERT TONE)

<TWO ROUNDS>

"MAY I HAVE YOU ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION

PLEASE. CARBON MONOXIDE HAS BEEN DETECTED IN THE BUILDING.

PLEASE LEAVE THE BUILDING BY THE NEAREST EXIT."

<PAUSE 2 SECONDS> REPEAT MESSAGE

3. (A HORN IS PLAYED FOR 4 SECONDS)

<TWO ROUNDS>

"MAY I HAVE YOUR ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION

PLEASE. A BOMB THREAT HAS BEEN REPORTED IN THE BUILDING.

PLEASE LEAVE THE BUILDING BY THE NEAREST EXIT DO NOT USE THE

ELEVATORS."

<PAUSE 2 SECONDS> REPEAT MESSAGE.

4. (A HORN IS PLAYED FOR 4 SECONDS)

<TWO ROUNDS>

"MAY I HAVE YOUR ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION

PLEASE. AN INTRUDER OR HOSTILE PERSON HAS BEEN REPORTED IN

THE BUILDING. PLEASE SEEK A DESIGNATED SAFE LOCATION

IMMEDIATELY."

<PAUSE 2 SECONDS> REPEAT MESSAGE.

5. (A HORN IS PLAYED FOR 4 SECONDS)

<TWO ROUNDS>

"MAY I HAVE YOU ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION

PLEASE. PLEASE SEEK A DESIGNATED SAFE LOCATION IMMEDIATELY"

<PAUSE 2 SECONDS> REPEAT MESSAGE

6. (A HORN IS PLAYED FOR 4 SECONDS)

<TWO ROUNDS>

"MAY I HAVE YOUR ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION

PLEASE. PLEASE LEAVE THE BUILDING BY THE NEAREST EXIT."

<PAUSE 2 SECONDS> REPEAT MESSAGE.

7. (A HORN IS PLAYED FOR 8 SECONDS)

<TWO ROUNDS>

"MAY I HAVE YOUR ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION

PLEASE. A WEATHER EMERGENCY HAS BEEN REPORTED IN THE

AREA. PLEASE SEEK A DESIGNATED SAFE LOCATION IMMEDIATELY;

DO NOT USE THE ELEVATORS."

<PAUSE 2 SECONDS> REPEAT MESSAGE.

8. (A HORN IS PLAYED FOR 4 SECONDS)

<ONE ROUND>

"MAY I HAVE YOUR ATTENTION PLEASE. MAY I HAVE YOUR ATTENTION

PLEASE. THE EMERGENCY HAS BEEN RESOLVED; RETURN TO

NORMAL OPERATIONS."

<PAUSE 2 SECONDS> REPEAT MESSAGE

9. (A HORN IS PLAYED FOR 8 SECONDS)

<ONE ROUND>

"TEST, TEST, TEST, THIS IS AN EMERGENCY NOTIFICATION AUDIO

SYSTEM TEST; YOU MAY CONTINUE NORMAL OPERATIONS, TEST,

TEST, TEST."

<PAUSE 2 SECONDS> REPEAT MESSAGE.

10. SPARE - NO MESSAGE

MASS NOTIFICATION MESSAGES

NOTES:

REFER TO FA001 FOR GENERAL NOTES, DESIGN CRITERIA,

ABBREVIATIONS AND SYMBOLS.

1.

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FA602

FIRE ALARM

MATRIX

18-0060

02-25-2021

C QUINN

C. CARRAS

Revisions

PROVIDE CEILING MOUNTED SPEAKERS AND CLEAR STROBES

AS REQUIRED TO ACHIEVE DESIGN CRITERIA.

PROVIDE CEILING MOUNTED SPEAKERS AS REQUIRED

TO ACHIEVE DESIGN CRITERIA.

NOTIFICATION APPLIANCES ARE NOT REQUIRED .

PROVIDE WEATHERPROOF WALL MOUNTED SPEAKERS, AS

REQUIRED TO ACHIEVE DESIGN CRITERIA.

FIRE ALARM HATCH LEGEND

NO HATCH

PROVIDE WEATHERPROOF WALL MOUNTED SPEAKERS AND

STROBES TO ACHEIVE THE DESIGN CRITERIA.

F

F

A

B

C

E

D.9

C.5

B.1

11.6

F

F

GPTB BAY

Office

Office

Corridor 7C

F

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F'

'D'

'B'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FA901-1F

FIRE ALARM AND

MNS PLAN -

LOWER LEVEL -

AREA F - OPTION

18-0060

02-25-2021

C. QUINN

C. CARRAS

NOTES:

REFER TO FA001 FOR GENERAL NOTES, DESIGN CRITERIA,

ABBREVIATIONS AND SYMBOLS.

WALL MOUNTED NOTIFICATION DEVICES ARE PERMITTED IN UNFINISHED

AREAS WITH CONGESTED CEILINGS SUCH AS A PUMP ROOM OR

MECHANICAL ROOM.

REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING

PLANS.

1.

2.

3.

0 4' 8' 16'1/8" = 1'-0"

FIRE ALARM AND MNS PLAN - LOWER LEVEL - OPTION 1

Revisions

AFF ABOVE FINISHED FLOOR

AHJ AUTHORITY HAVING JURISDICTION

AS AUTOMATIC SPRINKLER

FP FIRE PROTECTION

FM FIRE MAIN

(M) MECHANICALLY SUPERVISED

NC NORMALLY CLOSED

NO NORMALLY OPEN

RCP REFLECTED CEILING PLAN

RN RISER NIPPLE

(S) ELECTRICALLY SUPERVISED

SQ FT SQUARE FOOT

FIRE PROTECTION SPRINKLER SYSTEM DESIGN CRITERIA

PRESSURE RELIEF VALVE

OUTSIDE SCREW AND YOKE

VALVE (OS&Y)

VALVE

DOUBLE CHECK BACKFLOW

PREVENTER

INDICATING BUTTERFLY VALVE

FLOW TEST HEADER

CHECK VALVE

PIPE CAP

AUTOMATIC DRAIN VALVE

FIRE DEPARTMENT

CONNECTION

PRESSURE GAUGE

SIGHT GLASS

FLOW SWITCH

FIRE SUPPRESSION LEGEND

FIRE SUPPRESSION ABBREVIATIONS

FIRE SUPPRESSION DESIGN CRITERIA

FIRE SUPPRESSION GENERAL NOTES

DRAIN PIPING

PIPING SYMBOLS / LINE DESIGNATION

THRUST BLOCK

AUTOMATIC AIR RELEASE

VALVE

RISER LOCATION

HAZARD CLASSIFICATION

NOTE 1: PROVIDE 200 ºF RATED SPRINKLERS IN MECHANICAL, ELECTRICAL, VEHICLE MAINTENANCE BAY AND COMMUNICATION ROOMS.

NOTE 2: UPRIGHT SPRINKLER FINISH TO BE BRASS.

NOTE 3: DRY SIDEWALL SPRINKLERS SHALL BE BRASS, 200ºF, ORDINARY HAZARD

NOTE 4: PROVIDE GUARD FOR SPRINKLER IN ELEVATOR MACHINE ROOM AND ELEVATOR PIT.

NO HATCH

MARK

WET

SYSTEM

TYPE

WET

REMOTE

AREA

SQ FT

HOSE

DEMAND

GPM

TEMP

RATING (ºF)

TYPE

(CEILINGS)

ORDINARY

ORDINARY

QUICK RESPONSE

CONCEALED

QUICK RESPONSE

UPRIGHT

NOTES

1, 2, 3, 4

0.10

DENSITY

GPM/SF

0.20

MAXIMUM AREA

PER HEAD

SQ FT

LIGHT HAZARD

ORDINARY HAZARD

ADDITIONAL CODE

REFERENCE

SPRINKLER CHARACTERISTICS

K-FACTOR FINISH

5.6 OR 8.0

8.0

WHITE

FIRE SUPPRESSION SYSTEM

WET SYSTEM

ELBOW UP OR DOWN

TEE UP OR DOWN

SYSTEM PIPING

1. SERVE THE FIRE SUPPRESSION SYSTEM FROM THE

EXISTING DOMESTIC SYSTEM. PERFORM A HYDRANT

FLOW TEST, AND INCORPORATE THIS TEST INTO THE

HYDRAULIC CALCULATIONS. HYDRANT FLOW TESTING

SHALL BE IN ACCORDANCE WITH NFPA 291, AND THE

RESULTS OF THE TESTING SHALL BE SUBMITTED AS

INDICATED IN NFPA 291 FIGURE 4.11.2.

FOR INFORMATION ONLY: FLOW TEST 1

DATE 01/13/2021

STATIC 96 PSI

RESIDUAL 80 PSI

FLOW 1277 GPM

FLOW HYDRANT LOCATION: NORTH AT DEAD END.

GAUGE HYDRANT LOCATION: 770 FT NORTH OF

CAPEHART ROAD ON 25TH ST.

2. INCLUDE A 10% OR 5 PSI SAFETY FACTOR IN THE

HYDRAULIC CALCULATIONS, WHICHEVER IS GREATER.

3. THE FIRE SUPPRESSION SYSTEM SHALL BE DESIGNED

AND INSTALLED BY A LICENSED / CERTIFIED COMPANY

WHERE EMPLOYEES ARE LICENSED / CERTIFIED TO

INSTALL FIRE PROTECTION EQUIPMENT IN THE STATE OF

NEBRASKA.

4. ALL COMPONENTS AND ASSEMBLIES USED IN THIS FIRE

PROTECTION SYSTEM MUST BE SPECIFICALLY UL LISTED

OR FM APPROVED FOR THEIR INTENDED USE.

5. USE SCHEDULE 40 BLACK STEEL FIRE WATER PIPING ON

THIS PROJECT. PROVIDE PIPING MATERIAL SUITABLE

FOR USE IN POTABLE WATER SYSTEMS IN COMPLIANCE

WITH THE INTERNATIONAL PLUMBING CODE AND LOCAL

JURISDICTION PRIOR TO THE BACKFLOW PREVENTER.

1. PROVIDE ALL NECESSARY COMPONENTS FOR A WET-PIPE

SYSTEM IN THE READINESS CENTER. AT A MINIMUM

PROVIDE COMPONENTS AS INDICATED ON THESE

DRAWINGS. PROVIDE ADDITIONAL COMPONENTS AND

MODIFICATIONS AS REQUIRED TO PROVIDE A FULLY

FUNCTIONING FIRE SUPPRESSION SYSTEM.

2. THE FIRE SUPPRESSION SYSTEM SHALL BE SUPPLIED

FROM THE NEW DEDICATED INCOMING FIRE MAIN. REFER

TO CIVIL DRAWINGS.

3. COORDINATE ALL REQUIRED SYSTEMS TO THE

SATISFACTION OF THE ENGINEER AND AUTHORITY

HAVING JURISDICTION. CORRECT ANY DEFICIENCIES,

INCONSISTENCIES, OR POORLY COORDINATED

INSTALLATIONS AT NO ADDITIONAL COST.

4. FINAL DESIGN REQUIREMENTS (DEVICE QUANTITY, SIZE,

AND LOCATIONS) ARE THE SOLE RESPONSIBILITY OF THE

FIRE SUPPRESSION CONTRACTOR. DRAWINGS INDICATE

MINIMUM REQUIREMENTS; VERIFY AND COORDINATE

FINAL DESIGN REQUIREMENTS WITH THESE

CONSTRUCTION DOCUMENTS, SPECIFICATIONS,

REFERENCE DOCUMENTS, APPLICABLE CODES, AND

FACILITY USER REQUIREMENTS.

5. ALL DRAIN PENETRATIONS THROUGH EXTERIOR WALL

SHALL BE NO GREATER THAN 2'-0" ABOVE FINISHED

GRADE.

6. INSTALL FIRE PROTECTION PIPE HANGERS PER THE

FOLLOWING LIMITATIONS:

A. THE SINGLE POINT DEAD LOAD APPLIED TO ANY

STRUCTURAL MEMBER SHALL NOT EXCEED 300 LBS.

PROVIDE TRAPEZE HANGERS TO DISTRIBUTE THE

LOAD BETWEEN STRUCTURAL MEMBERS WHERE A

SINGLE HANGER EXCEEDS THE LIMITATIONS.

B. SIX INCH DIAMETER PIPE ROUTED PERPENDICULAR

TO JOISTS SHALL BE SUPPORTED AT A JOIST PANEL

POINTS.

C. SIX INCH DIAMETER PIPE ROUTED PERPENDICULAR

TO JOISTS SHALL BE SUPPORTED ON ALTERNATE

JOISTS.

7. ALL VALVES INCLUDING CONTROL AND TRIM VALVES

SHALL BE WITHIN 6'-0" AFF.

TYPE

(EXPOSED)

QUICK RESPONSE

UPRIGHT

QUICK RESPONSE

CONCEALED

SPRINKLER SYSTEM BOUNDARY

1, 2

WHITE

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FX001

FIRE

SUPPRESSION

NOTES, LEGEND

AND

ABBREVIATIONS

18-0060

02-25-2021

C. QUINN

C. CARRAS

Revisions

HAZARD

CLASSIFICATION

HAZARD SCHEDULE

LIGHT HAZARD CEILING

HEIGHT

NO HATCH

MARK

ORDINARY HAZARD

SPRINKLER FEED

MAIN FROM ABOVE2

A

B

C

E

F

G

H

L

N

P

K.5

J.9

H.9

G.5

F.3

D.9

C.5

B.1

9.2 9.8 10.6 10.8 11.6

8.7 9.7

10.5

11 12

CORR

RECEIVING

ELEV EQUIP

CST STORAGE

STAIR

CONF

CST LOG / ADMIN

08A

MECH

ELEC

GROUNDS &

MAINTENANCE

FLAMMABLE

STORAGE

IT

CST READY

BAYS

CUST

TOILET

TOILET

OFFICE

36A

CST SURVEY

CST COMMO

OFFICE

29A

CST MED

SUPPORT

OFFICE

28A

CST MED STOR

36B

IT

ELEC

CST

OPERATIONS

OFFICE

29B

OFFICE

28B

CST COMMAND

OFFICE

28C

MECH

TRAINING AID

STORAGE

29C

PLUMBING

CHASE

30E

CORRIDOR

7B

CORR

STAIR

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F'

'D'

'B'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FX101-1A

FIRE

SUPPRESSION

PLAN - LOWER

LEVEL - OVERALL

18-0060

02-25-2021

C. QUINN

C. CARRAS

NOTES:

REFER TO FX001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

MINIMUM NUMBER OF LOW POINT DRAINS INDICATED

ON DRAWINGS. PROVIDE ADDITIONAL LOW POINT

DRAINS AS REQUIRED BY NFPA-13.

PROVIDE AIR VENTS AT HIGH POINT OF EACH

SPRINKLER SYSTEM. PROVIDE DRAINS TO DISCHARGE

TO EXTERIOR.

COORDINATE SPRINKLER LOCATIONS WITH REFLECTED

CEILING PLANS. REFER TO ARCHITECTURAL DRAWINGS

FOR REFLECTED CEILING PLANS.

COORDINATE SPRINKLER LOCATIONS WITH DUCTWORK

OBSTRUCTIONS IN ROOMS NOT PROVIDED WITH A

CEILING IN ACCORDANCE WITH NFPA-13

REQUIREMENTS. REFER TO MECHANICAL DRAWINGS

FOR DUCTWORK LOCATIONS.

1.

1/16" = 1'-0"

FIRE SUPPRESSION PLAN - LOWER LEVEL - OVERALL

SCALE IN FEET

0 8' 16' 32'

KEYED NOTES:

INSTALL SPINKLERS UNDER OVERHEAD DOORS PER

NFPA 13

PROVIDE SPRINKLERS IN ELEVATOR PIT PER DETAIL 3

ON SHEET FX601

PROVIDE SPRINKLER CONTROL VALVE PER DETAIL 4

ON SHEET FX601

SPRINKLER PIPE ROUTING IN CORRIDOR SHALL AVOID

ONE-FOOT CLEARANCE ABOVE CABLE TRAY.

2.

3.

4.

5.

Revisions

11/17/2020 02/25/2021

WC

SYSTEM 2

SYSTEM 1

SYSTEM 3

C

E

F

G

H

J

K

L

M

N

N.5

P

Q

R

K.5

J.9

H.9

G.5

F.3

D.9

C.5

2.6 3.6 4.8 5.4 7.6 8.6 9.8 10.6 10.8 11.6

1 2 3

3.5

4 5

5.1

5.9

6.7

7.7

8.7 9.7

10.5

11 12

ASSEMBLY

CLASSROOM/

LECTURE

FAMILY

READINESS

RECRUITING

LEARNING

CENTER

DISPLAY

101A

LACTATION

LOCKERS

CLASSROOM

BREAK /

VENDING

CLASSROOM

TRAINING

VEST

MECH / WATER

SERVICE

ANTE

105A

ANTE

105B

PHYSICAL

FITNESS

MEN

WOMEN

ISSUING

BEVERAGES

158B

MEDICAL

TABLE / CHAIR

STORAGE

104A

KITCHEN

160 SERVING

158A

LOBBY / MAIN

HALL

CORR

CORR

ELEC

IT

VAULT

153A

ARMORER

ISSUING

ISSUING

152.1

WOMEN

LOCKERS

108A

MEN LOCKERS

110A

MECH

ELEC

CUST

IT

PANTRY /

OFFICE

160D

CUST

160C

TOILET

160B

SCULLERY

160A

CORR

157B

CORR

157A

CORR

CORR

101CALCOVE

101B

ALCOVE

101D

LIFT EQUIP

105C

MEN SHOWERS

110B

WOMEN

SHOWERS

108B

TOILET

CONF

OFFICE

OFFICE

WORK RM

OPEN OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CONF

OFFICE

OFFICE

MECH

WORK RM

OPEN OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

PLUMBING

CHASE

109C

PLUMBING

CHASE

111C

PLUMBING

CHASE

30D

ISSUING

157E

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

CORR

101E

ELEV LOBBY /

STAIR

101F

HEATED

STORAGE

FX601

ELEV: 94' 2"

HEATED

STORAGE

HAZARD

CLASSIFICATION

HAZARD SCHEDULE

LIGHT HAZARD CEILING

HEIGHT

NO HATCH

MARK

ORDINARY HAZARD

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F''E'

'C' 'D'

'B' 'A'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FX101-2A

FIRE

SUPPRESSION

PLAN - MAIN

LEVEL - AREA A,

B, C & D

18-0060

02-25-2021

C. QUINN

C. CARRAS

1/16" = 1'-0"

FIRE SUPPRESSION PLAN - MAIN LEVEL - AREA A, B, C & D

KEYED NOTES:

FIRE PROTECTION RISER DOWN TO LOWER LEVEL

ROUTE FEED MAINS FOR STAIRWELL RISERS ABOVE

CEILING IN CORRIDOR.

PROVIDE SPRINKLER COVERAGE IN THE MAIN HALL

IN ACCORDANCE WITH NFPA 13 TABLE 9.2.7.1.

WET CHEMICAL SUPPRESSION SYSTEM FOR

COOKING APPLIANCES PROVIDED BY KITCHEN HOOD

SUBCONTRACTOR.

PROVIDE LOW POINT DRAIN. PROVIDE CAPPED

DRAIN CONNECTION LOCATED IN MECHANICAL ROOM

107.

PROVIDE LOW POINT DRAIN DISCHARGE TO MOP

SINK LOCATED IN CUSTODIAN CLOSET.

REDUCE PIPE SIZE TO 4" PRIOR TO ENTERING

COLUMN ENCLOSURE. ENLARGE PIPE SIZE AFTER

EXITING COLUMN ENCLOSURE AS REQUIRED TO

MEET HYDRAULIC REQUIREMENTS. COORDINATE

REQUIRED OPENING IN PRECAST WALL PANEL FOR

PIPE EXITING COLUMN ENCLOSURE FOR

INSTALLATION OF FITTINGS AND COUPLINGS.

REFER TO CIVIL PLANS FOR CONTINUATION.

SCALE IN FEET

0 8' 16' 32'

NOTES:

REFER TO FX001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

MINIMUM NUMBER OF LOW POINT DRAINS INDICATED

ON DRAWINGS. PROVIDE ADDITIONAL LOW POINT

DRAINS AS REQUIRED BY NFPA-13.

PROVIDE AIR VENTS AT HIGH POINT OF EACH

SPRINKLER SYSTEM. PROVIDE DRAINS TO DISCHARGE

TO EXTERIOR.

REFER TO ARCHITECTURE DRAWINGS FOR REFLECTED

CEILINGS. COORDINATE ALL SPRINKLER LOCATIONS

WITH CEILING AND OBSTRUCTIONS

COORDINATE SPRINKLER LOCATIONS WITH DUCTWORK

OBSTRUCTIONS IN ROOMS NOT PROVIDED WITH A

CEILING IN ACCORDANCE WITH NFPA-13

REQUIREMENTS. REFER TO MECHANICAL DRAWINGS

FOR DUCTWORK LOCATIONS.

VARIATION IN ROUTING OF FEED MAINS SHALL BE

APPROVED BY THE ARCHITECT.

1.

2.

3.

4.

5.

6.

1 / FX101 - 2E

Revisions

HAZARD

CLASSIFICATION

HAZARD SCHEDULE

LIGHT HAZARD CEILING

HEIGHT

NO HATCH

MARK

ORDINARY HAZARD

A

B

C

B.1

2.6 3.6 4.8 5.4 7.6 8.6 9.2 9.8 10.6 10.8 11.6

ELEC

157D

IT

157C

LOCKERS

CORR

MECH

OPEN OFFICE

HEATED

STORAGE

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F''E'

'C' 'D'

'B' 'A'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FX101-2E

FIRE

SUPPRESSION

PLAN - MAIN

LEVEL - AREA E &

F

18-0060

02-25-2021

C. QUINN

C. CARRAS

1/16" = 1'-0"

FIRE SUPPRESSION PLAN - MAIN LEVEL - AREA E & F

SCALE IN FEET

0 8' 16' 32'

NOTES:

REFER TO FX001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

COORDINATE SPRINKLER LOCATIONS WITH REFLECTED

CEILING PLANS. REFER TO ARCHITECTURAL DRAWINGS

FOR REFLECTED CEILING PLANS.

COORDINATE SPRINKLER LOCATIONS WITH DUCTWORK

OBSTRUCTIONS IN ROOMS NOT PROVIDED WITH A

CEILING IN ACCORDANCE WITH NFPA-13

REQUIREMENTS. REFER TO MECHANICAL DRAWINGS

FOR DUCTWORK LOCATIONS.

VARIATION IN ROUTING OF FEED MAINS SHALL BE

APPROVED BY THE ARCHITECT.

REFER TO ARCHITECTURE DRAWINGS FOR REFLECTED

CEILINGS. COORDINATE ALL SPRINKLER LOCATIONS

WITH CEILING AND OBSTRUCTIONS.

1.

KEYED NOTES:

PROVIDE DRY SIDEWALL SPRINKLERS TO PROTECT

AREA UNDER DOCK CANOPY.

1 / FX101 - 2A

2.

3.

4.

5.

Revisions

SYSTEM

2 LOWER

LEVEL

27,327 SQ FT

A

B

C

E

F

G

H

L

N

P

Q

K.5

J.9

H.9

G.5

F.3

D.9

C.5

B.1

7.6 8.6 9.2 9.8 10.6 10.8 11.6

6.7

7.7

8.7 9.7

10.5

11 12

(INCLUDING OPTION 1)

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F'

'D'

'B'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FX111-1A

SPRINKLER

BOUNDARIES -

LOWER LEVEL -

OVERALL

18-0060

02-25-2021

C. QUINN

C. CARRAS

1/16" = 1'-0"

LOWER LEVEL - OVERALL

SCALE IN FEET

0 8' 16' 32'

NOTES:

REFER TO FX001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

COORDINATE SPRINKLER LOCATIONS WITH REFLECTED

CEILING PLANS. REFER TO ARCHITECTURAL DRAWINGS

FOR REFLECTED CEILING PLANS.

COORDINATE SPRINKLER LOCATIONS WITH DUCTWORK

OBSTRUCTIONS IN ROOMS NOT PROVIDED WITH A

CEILING IN ACCORDANCE WITH NFPA-13

REQUIREMENTS. REFER TO MECHANICAL DRAWINGS

FOR DUCTWORK LOCATIONS.

VARIATION IN ROUTING OF FEED MAINS SHALL BE

APPROVED BY THE ARCHITECT.

REFER TO ARCHITECTURE DRAWINGS FOR REFLECTED

CEILINGS. COORDINATE ALL SPRINKLER LOCATIONS

WITH CEILING AND OBSTRUCTIONS

SPRINKLER SYSTEM BOUNDARY INCLUDES FLOOR

AREA OF ALL ABI'S.

1.

2.

3.

4.

5.

6.

KEYED NOTES

1 PROVIDED AS PART OF OPTION 1. REFER TO

FX901-1F.

Revisions

ID Date Description

SYSTEM

1 MAIN

LEVEL

SYSTEM 3

MAIN LEVEL,

SOUTH

WING

43,000 SQ FT

32,000 SQ FT

A

B

C

E

F

G

H

J

K

L

M

N

N.5

P

Q

R

K.5

J.9

H.9

G.5

F.3

D.9

C.5

B.1

2.6 3.6 4.8 5.4 7.6 8.6 9.2 9.8 10.610.8 11.6

1 2 3

3.5

4 5

5.1

5.9

6.7

7.7

8.7 9.7

10.5

11 12

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F''E'

'C' 'D'

'B' 'A'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FX111-2A

SPRINKLER

BOUNDARIES -

MAIN LEVEL -

OVERALL

18-0060

02-25-2021

C. QUINN

C. CARRAS

1" = 20'-0"

MAIN LEVEL - OVERALL

SCALE IN FEET

0 20' 40'10'

NOTES:

REFER TO FX001 FOR GENERAL NOTES, DESIGN

CRITERIA, ABBREVIATIONS AND SYMBOLS.

COORDINATE SPRINKLER LOCATIONS WITH REFLECTED

CEILING PLANS. REFER TO ARCHITECTURAL DRAWINGS

FOR REFLECTED CEILING PLANS.

COORDINATE SPRINKLER LOCATIONS WITH DUCTWORK

OBSTRUCTIONS IN ROOMS NOT PROVIDED WITH A

CEILING IN ACCORDANCE WITH NFPA-13

REQUIREMENTS. REFER TO MECHANICAL DRAWINGS

FOR DUCTWORK LOCATIONS.

VARIATION IN ROUTING OF FEED MAINS SHALL BE

APPROVED BY THE ARCHITECT.

REFER TO ARCHITECTURE DRAWINGS FOR REFLECTED

CEILINGS. COORDINATE ALL SPRINKLER LOCATIONS

WITH CEILING AND OBSTRUCTIONS.

SPRINKLER SYSTEM BOUNDARY INCLUDES FLOOR

AREA OF ALL ABI'S.

1.

2.

3.

4.

5.

6.

Revisions

FROM HEADER

DRAIN TO

EXTERIOR

TO WET

SYSTEM

AUTOMATIC AIR

VENT LOCATED AT

HIGH POINT IN

SYSTEM.

INSPECTOR'S

TEST

MAIN DRAIN

PRESSURE

RELIEF

VALVE

(SET AT

175 PSI)

FROM SPRINKLER SYSTEM (S)

ELEV. MACHINE ROOM

TO RISER MAIN DRAIN

OR OTHER EXTERIOR

LOCATION

INSPECTORS TEST VALVE

TO SPRINKLER

LOWER LEVEL

FROM LOWER LEVEL

SPRINKLER LINE

M

A X

SIDEWALL SPRINKLER

S

(S)

T O

W E

T S

Y S

T E

M

(S)

(S)

AUXILIARY DRAIN VALVESPLASH BLOCK FLANGED CONNECTION

MAIN DRAIN

EXTERIOR WALL 1

FX601

BY DIVISION 21

T O

W E

T S

Y S

T E

M

(S)

T O

W E

T S

Y S

T E

M

(S)

(S

N C

FX601

FX601

BY DIVISION 33

2.6

Exterior Wall

FDC

TEST

HEADER

DOUBLE CHECK BACKFLOW

PREVENTER

BUTTERFLY

VALVE

TO WET SYSTEM 3 TO WET SYSTEM 2

TO WET SYSTEM 1

BUTTERFLY VALVE INSTALLED

IN VERTICAL (TYP.)

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:0

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FX601

FIRE

SUPPRESSION

RISER, DETAILS,

AND ENLARGED

PLANS

18-0060

02-25-2021

C. QUINN

C. CARRAS

NTS

WET RISER DETAIL

NTS

ELEVATOR MACHINE ROOM SECTION DETAIL

NTS

ELEVATOR PIT SPRINKLER DETAIL

NTS

WET RISER ROOM DETAIL

1/2" = 1'-0"

MECH/WATER SERVICE - ROOM 156 PLAN

0 1' 2' 4'

Revisions

A

B

C

E

F

F.3

D.9

C.5

B.1

11.6

GPTB BAY

Office

Office

Corridor 7C

Hall

HAZARD

CLASSIFICATION

HAZARD SCHEDULE

LIGHT HAZARD CEILING

HEIGHT

NO HATCH

MARK

ORDINARY HAZARD

SHEET NUMBER

SHEET TITLE

CLIENT INFORMATION

PROJECT INFORMATION

JOB #

ISSUE DATE

Checked by Drawn by

Davis Design All Rights Reserved

E a s t

M a in

S u it e

V e rm ill io n S

D

P h o n e

-6

-1

V e rm il li o n

N S tr e e t, S u it e

L in c o ln N

E

P h o

-4

-9

F a x

-4

-9

L in c o ln L in c o ln

N th

S tr e e t, S u it e

O m a h a

N E

-4

-3

W a rd

P a rk w a y

K a n s a s C it y

M O

-3

-9

'F'

'D'

'B'

C

R e v it

P ro je c t s \1

F

C e n tr a l_ c ca rr a s b u rn s m c d

.c o m .r v t

/2

/2

:2

:1

A

M

Nebraska Army National Guard

BELLEVUE

READINESS

CENTER

S. 25th and Capehart Rd., Bellevue, NE

FX901-1F

FIRE

SUPPRESSION

PLAN - LOWER

LEVEL - AREA F -

OPTION 1

18-0060

02-25-2021

C. QUINN

C. CARRAS

NOTES:

REFER TO FX001 FOR GENERAL NOTES, DESIGN CRITERIA,

ABBREVIATIONS AND SYMBOLS.

MINIMUM NUMBER OF LOW POINT DRAINS INDICATED ON DRAWINGS.

PROVIDE ADDITIONAL LOW POINT DRAINS AS REQUIRED BY NFPA-13.

PROVIDE AIR VENTS AT HIGH POINT OF EACH SPRINKLER SYSTEM.

PROVIDE DRAINS TO DISCHARGE TO EXTERIOR.

COORDINATE SPRINKLER LOCATIONS WITH REFLECTED CEILING PLANS.

REFER TO ARCHITECTURAL DRAWINGS FOR REFLECTED CEILING

PLANS.

COORDINATE SPRINKLER LOCATIONS WITH DUCTWORK OBSTRUCTIONS

IN ROOMS NOT PROVIDED WITH A CEILING IN ACCORDANCE WITH

NFPA-13 REQUIREMENTS. REFER TO MECHANICAL DRAWINGS FOR

DUCTWORK LOCATIONS.

KEYED NOTES:

INSTALL SPRINKLERS UNDER OVERHEAD DOORS PER NFPA 13.1

1.

2.

3.

4.

5.

1/8" = 1'-0"

FIRE SUPPRESSION PLAN - LOWER LEVEL - OPTION 1

0 4' 8' 16'

Revisions

FIRE PROTECTION
FA001 - FIRE ALARM NOTES, LEGEND AND ABBREVIATIONS
FA101-1A - FIRE ALARM AND MNS PLAN - LOWER LEVEL - OVERALL
FA101-2A - FIRE ALARM AND MNS PLAN - MAIN LEVEL - AREA A, B, C & D
FA101-2E - FIRE ALARM AND MNS PLAN - MAIN LEVEL - AREA E & F
FA501 - FIRE ALARM DETAILS
FA601 - FIRE ALARM ONE-LINE DIAGRAM
FA602 - FIRE ALARM MATRIX
FA901-1F - FIRE ALARM AND MNS PLAN - LOWER LEVEL - AREA F - OPTION 1
FX001 - FIRE SUPPRESSION NOTES, LEGEND AND ABBREVIATIONS
FX101-1A - FIRE SUPPRESSION PLAN - LOWER LEVEL - OVERALL
FX101-2A - FIRE SUPPRESSION PLAN - MAIN LEVEL - AREA A, B, C & D
FX101-2E - FIRE SUPPRESSION PLAN - MAIN LEVEL - AREA E & F
FX111-1A - SPRINKLER BOUNDARIES - LOWER LEVEL - OVERALL
FX111-2A - SPRINKLER BOUNDARIES - MAIN LEVEL - OVERALL
FX601 - FIRE SUPPRESSION RISER, DETAILS, AND ENLARGED PLANS
FX901-1F - FIRE SUPPRESSION PLAN - LOWER LEVEL - AREA F - OPTION 1

File details come from the government source that posted it. Updated .