BATT INSULATION
BRICK
CONCRETE
EARTH MATERIALS
GRAVEL
GYPSUM BOARD
PLYWOOD
STEEL RIGID INSULATION
WOOD
ALUMINUM
PRE-CAST CONCRETE
WOOD BLOCKING
CONCRETE MASONRY
UNIT
15 East Main, Suite 201 Vermillion SD 57069 Phone 605-624-1081
FAX: (402) 476-9722
1221 N Street, Suite 600 Lincoln NE 68508
Phone 402-476-9700 Fax 402-476-9722
LINCOLN: VERMILLION:
DAVIS DESIGN PROJECT NUMBER:
DATE:
MATERIAL SYMBOLS
INDEX OF DRAWINGS
VICINITY MAPREFERENCE SYMBOLS
GENERAL REFERENCE DETAIL
A-101
INDICATES DETAIL NUMBER
INDICATES SHEET UPON WHICH DETAIL
APPEARS
BUILDING SECTION REFERENCE
A-301
A-301
A-401
WALL SECTION REFERENCE
COLUMN LINE NUMBER
A
A-201
ELEVATION REFERENCES
A-201
OR
PLAN ELEVATION REFERENCE
FLOOR LEVEL
100'-0"
A-401
DETAIL REFERENCE
OR
A-401
PARTITION TYPE TAG
WINDOW TAG
DOOR NUMBER
a
101a
ROOF TITLE/ NUMBER
ROOM NAME
ROOM ##
PARTITION TYPE MARK
I, AM THE COORDINATING
PROFESSIONAL ON THE
Nebraska National Guard
Bellevue Readiness Center
18-0060
02/25/21
S. 25th and Capehart Rd., Bellevue, NE
S. 25th and Capehart Rd., Bellevue, NE
Brandon Sire
Bellevue Readiness Center
INDEX ARCHITECTURAL
A-101-1B Lower Level Floor Plan - Area B
A-101-1D Lower Level Floor Plan - Area D
A-101-2A Main Level Floor Plan - Area A
A-101-2B Main Level Floor Plan - Area B
A-101-2C Main Level Floor Plan - Area C
A-101-2D Main Level Floor Plan - Area D
A-101-2E Main Level Floor Plan - Area E
A-102 Clerestory Plan
A-103-1B Lower Level Reflected Ceiling Plan - Area B
A-103-1D Lower Level Reflected Ceiling Plan - Area D
A-103-2A Main Level Reflected Ceiling Plan - Area A
A-103-2B Main Level Reflected Ceiling Plan - Area B
A-103-2C Main Level Reflected Ceiling Plan - Area C
A-103-2D Main Level Reflected Ceiling Plan - Area D
A-103-2E Main Level Reflected Ceiling Plan - Area E
A-103-MH Main Hall and Assembly Ceiling Plans
A-104 Roof Plan
A-105 Enlarged Plans
A-106 Main Hall Jointing / Concrete Staining Plan
A-201 Exterior Elevations
A-202 Exterior Elevations
A-203 Exterior Elevations
A-204 Exterior Elevations
A-206 Interior Elevations
A-207 Interior Elevations
A-208 Interior Elevations
A-209 Interior Elevations
A-210 Interior Elevations
A-211 Interior Elevations
A-212 Interior Elevations
A-301 Building Cross Sections
A-302 Building Cross Sections
A-303 Building Cross Sections
A-304 Building Cross Sections
A-401 Wall Sections
A-402 Wall Sections
A-403 Wall Sections
A-404 Wall Sections
A-405 Wall Sections
A-406 Wall Sections
A-407 Stair Sections and Details
A-408 Elevator Sections and Details
A-501 Sections and Details
A-502 Sections and Details
A-503 Plan Details
A-504 Plaza Wall Signage & Refuse Enclosure
A-601 Door, Door Frame, Interior Window Frame and Partition Schedules
A-602 Window and Aluminum Frame Schedule
A-603 Precast Panel Elevations
A-604 Precast Panel Elevations
A-605 Precast Panel Elevations
A-606 Precast Panel Elevations
A-607 Precast Panel Elevations - Options 1 & 2
A-701 Casework Sections
A-702 Security Cage Enclosures
A-703 Miscellaneous Details
A-704 Loading Dock Roof and Roof Access Details
A-901 Option 1 - GPTB Addition
A-902 Option 1 - GPTB Addition
A-903 Option 1 - GPTB Addition
A-904 Option 2 - Standby Generator and Option 4 - Operable Wall
A-905 Option 5 - Monument Sign and Option 6 - Roof Terrace
INDEX GENERAL - VOLUME 1
G-100.1 Cover Page - Volume 1
G-101 Regulatory Plans - Main Level
G-102 Regulatory Plans - Lower Level
G-103 Abbreviations & 2010 ADA Accessibility Standards
G-104 Survey
INDEX CIVIL
C-001 GENERAL CIVIL NOTES
INDEX STRUCTURAL
S-001 General Notes, Schedules, & Details
S-101-1B Lower Level Foundation Plan - Area B
S-101-1D Lower Level Foundation Plan - Area D
S-101-2A Main Level Foundation Plan - Area A
S-101-2C Main Level FoundationPlan - Area C
S-101-2E Main Level Foundation Plan - Area E
S-103-1B Main Level Framing Plan - Area B
S-103-1D Main Level Framing Plan - Area D
S-103-2A Roof Framing Plan - Area A
S-103-2B Roof Framing Plan - Area B
S-103-2C Roof Framing Plan - Area C
S-103-2D Roof Framing Plan - Area D
S-103-2E Roof Framing Plan - Area E
S-103-3A Main Hall Roof Framing Plan - Area A
S-103-3B Main Hall Roof Framing Plan - Area B
S-103-4C Assembly Hall Roof Framing Plan - Area C
S-501 Details
S-502 Details
S-503 Details
S-504 Details
S-505 Details
S-506 Details
S-507 Details
S-508 Retaining Wall Details
S-509 Retaining Wall Details
S-510 Special Joists Details
S-601 Schedule
S-901-1F Lower Level Foundation Plan - Area F (Option 1)
S-902-1F Lower Level Roof Framing Plan - Area F (Option 1)
S-903-1E Screen Wall / Generator Pad - Area E (Option 2)
INDEX INTERIOR
I-001 Lower Level Finish Floor Plan
I-002 Main Level Finish Floor Plan
I-101-1B Lower Level Finish Floor Plan - Area B
I-101-1D Lower Level Finish Floor Plan - Area D
I-101-2A Main Level Finish Floor Plan - Area A
I-101-2B Main Level Finish Floor Plan - Area B
I-101-2C Main Level Finish Floor Plan - Area C
I-101-2D Main Level Finish Floor Plan - Area D
I-101-2E Main Level Finish Floor Plan - Area E
I-105 Enlarged Kitchen Plan & Detail
I-601 Material List & Room Finish Schedule
SHEET NUMBER
SHEET TITLE
CLIENT INFORMATION
PROJECT INFORMATION
JOB #
ISSUE DATE
Checked by Drawn by
Davis Design All Rights Reserved
E a s t
M a in
S u it e
V e rm ill io n S
D
P h o n e
-6
-1
V e rm il li o n
N S tr e e t, S u it e
L in c o ln N
E
P h o n e
-4
-9
F a x
-4
-9
L in c o ln L in c o ln
N th
S tr e e t, S u it e
O m a h a
N E
-4
-3
W a rd
P a rk w a y
K a n s a s C it y
M O
-3
-9
D
R e v it
L o c a l2
\1
-0
-A
IS
V
R C d a n .w a rn e r6
R
A Q
.r v t
/2
/2
:4 : 5
A
M
Nebraska National Guard
Bellevue Readiness Center S. 25th and Capehart Rd., Bellevue, NE
G-100.1
Cover Page - Volume 1
18-0060
02/25/21
BS
DW
INDEX LANDSCAPE
L-101 SITE PLANTING PLAN
L-901 SITE PLANTING PLAN - OPTION 1 & 3
INDEX REFERENCE SHEETS
A-001 LOWER LEVEL REFERENCE FLOOR PLAN
INDICATING OPTIONS
A-002 MAIN LEVEL REFERENCE FLOOR PLAN
INDICATING OPTIONS
INDEX FURNITURE, FIXTURES & EQUIPMENT
FFE-101 Lower Level Furniture Plan
FFE-102 Main Level Furniture Plan
FFE-103 CST Equipment Plan
INDEX FOOD SERVICE
FS-101 Enlarged Kitchen Plan and Equipment Schedule
FS-301 HOOD DETAILS
FS-302 HOOD DETAILS
FS-303 HOOD DETAILS
FS-304 HOOD DETAILS
NEARNG PROJECT NUMBER: 310102
REFERENCE THE SHEETS IDENTIFIED BELOW FOR EACH OPTION. THIS
LIST IS PROVIDED FOR REFERENCE ONLY, CONTRACTOR SHALL VERIFY
ALL ASSOCIATED WORK WITH EACH OPTION
OPTION 1: CS902, CG902, CU902, L-901, S-901-1F, S-902-1F, A-205, A-607,
A-901, A-902, FA-901-1F, FX-901-1F, P-901-1D, P-902-1F, P-903-2D, P-904-1F,
P-906, P-907, P-908, M-901-1F, M-902-1F, M-903, M-904, M-905, E-901, E-902, E-903, E-906, ES-901, T-901, OPTION 2: CS901, CG901, S-903-1E, A-205, A-607, A-903, E-601, E-904, ES902
OPTION 3: CD905, CD906, CS903, CS905, CS906, CG903, CG905, CG906,
L-901, ES903, ES904
OPTION 4: A-903
OPTION 5: CS901, CG901, A-904
OPTION 6: A-904
OPTION 7: E-905, E-906
OPTION 8: CS901, CS903, CS904, CP901, CP904, CP911, CP914 , CG901,
CG904
OPTION 9: CS901, CS902, CS905, CP901, CP902, CP903, CP905, CP911,
CP913, CP915
References in the specificaitons to equipment, material, articles, or patented processes by trade name, make, or catalog number, shall be regarded as establishing a standard of quality and shall not be construed as limiting competition.
CD100 OVERALL DEMOLITION PLAN
CD101 DEMOLITION PLAN 1
CD102 DEMOLITION PLAN 2
CD103 DEMOLITION PLAN 3
CD104 DEMOLITION PLAN 4
CD105 DEMOLITION PLAN 5
CD106 DEMOLITION PLAN 6
CD107 DEMOLITION PLAN 7
CD905 BID OPTION 3 DEMOLITION PLAN 1
CD906 BID OPTION 3 DEMOLITION PLAN 2
CS100 OVERALL SITE PLAN
CS101 SITE PLAN 1
CS102 SITE PLAN 2
CS103 SITE PLAN 3
CS104 SITE PLAN 4
CS105 SITE PLAN 5
CS106 SITE PLAN 6
CS107 SITE PLAN 7
CS108 COORDINATE POINT TABLES
CS501 SITE DETAILS 1
CS502 SITE DETAILS 2
CS503 SITE DETAILS 3
CS504 SITE DETAILS 4
CS505 SITE DETAILS 5
CS506 SITE DETAILS 6
CS507 SITE DETAILS 7
CS900 OVERALL BID OPTION SITE PLAN
CS901 BID OPTION 2, 5, 8 AND 9 SITE PLAN
CS902 BID OPTION 1 AND 9 SITE PLAN
CS903 BID OPTION 8 SITE PLAN
CS904 BID OPTION 8 SITE PLAN
CS905 BID OPTION 3 AND 9 SITE PLAN
CS906 BID OPTION 3 SITE PLAN
CP101 JOINTING PLAN 1
CP102 JOINTING PLAN 2
CP103 JOINTING PLANS 3 AND 4
CP111 JOINTING ELEVATION PLAN 1
CP112 JOINTING ELEVATION PLAN 2
CP113 JOINTING PLAN 3 AND 4
CP901 BID OPTION 8 AND 9 JOINTING PLAN
CP902 BID OPTION 9 JOINTING PLAN
CP903 BID OPTION 9 JOINTING PLAN
CP904 BID OPTION 8 JOINTING PLAN
CP905 BID OPTION 9 JOINTING PLAN
CP911 BID OPTION 8 AND 9 JOINTING ELEVATION PLAN
CP912 BID OPTION 9 JOINTING ELEVATION PLAN
CP913 BID OPTION 9 JOINTING ELEVATION PLAN
CP914 BID OPTION 8 JOINTING ELEVATION PLAN
CP915 BID OPTION 9 JOINTING ELEVATION PLAN
CG100 OVERALL GRADING PLAN
CG101 GRADING PLAN 1
CG102 GRADING PLAN 2
CG103 GRADING PLAN 3
CG104 GRADING PLAN 4
CG105 GRADING PLAN 5
CG106 GRADING PLAN 6
CG107 GRADING PLAN 7
CG501 GRADING DETAILS 1
CG502 GRADING DETAILS 2
CG901 BID OPTION 2, 5 AND 8 GRADING PLAN
CG902 BID OPTION 1 GRADING PLAN
CG903 BID OPTION 3 GRADING PLAN
CG904 BID OPTION 8 GRADING PLAN
CG905 BID OPTION 3 GRADING PLAN
CG906 BID OPTION 3 GRADING PLAN
INDEX CIVIL (Cont.)
CU100 OVERALL UTILITY PLAN
CU101 UTILITY PLAN 1
CU102 UTILITY PLAN 2
CU103 UTILITY PLAN 3
CU104 UTILITY PLAN 4
CU105 UTILITY PLAN 5
CU106 UTILITY PLAN 6
CU107 UTILITY PLAN 7
CU201 STORM PROFILES 1
CU202 STORM PROFILES 2
CU203 STORM PROFILES 3
CU204 STORM PROFILES 4
CU211 SANITARY PROFILES 1
CU212 SANITARY PROFILES 2
CU213 SANITARY PROFILES 3
CU221 WATER PROFILES 1
CU222 WATER PROFILES 2
CU223 WATER PROFILES 3
CU224 WATER PROFILES 4
CU231 GAS PROFILES
CU501 UTILITY DETAILS 1
CU502 UTILITY DETAILS 2
CU503 UTILITY DETAILS 3
CU504 UTILITY DETAILS 4
CU902 BID OPTION 1 UTILITY PLAN
CU903 BID OPTION 3 UTILITY PLAN
CU905 BID OPTION 3 UTILITY PLAN
CU906 BID OPTION 3 UTILITY PLAN
SITE LOCATION
Revisions
ID Date Description
02/25/2021
2/25/2021
XX
OCCUPANT LOAD:
INDICATES THE OCCUPANCY OF
ROOM OR SPACE BASED ON
TABULAR LOAD FACTOR
OCCUPANCY LOAD FOR ROOM OR
SPACE
AGGREGATE LOAD:
TOTAL LOAD OF SPACE INCLUDING ALL
LOADS FROM OTHER SPACES
EXIT:
INDICATES LOAD AT EXIT
AND EXIT WIDTH
REQUIREMENTS
EXIT DOOR WIDTH REQUIRED (IN
INCHES) PER TABLE 1005.1
OCCUPANT LOAD
EXIT WIDTH PROVIDED (IN INCHES)
XX
XX
XX
XX
REGULATORY INFORMATION
ROOM SQUARE FOOT AREAXXX SF
1-HOUR FIRE BARRIER (OCCUPANCY AND EGRESS SEPARATION)
2-HOUR SHAFT WALL
SMOKE PARTITION
WALL MOUNTED FIRE EXTENGUISHER ON WALL BRACKET, BY OTHERS
FIRE EXTENGUISHER CABINET (FIRE EXTINGUISHER BY OTHERS)FEC
FE
ACCUMULATED OCCUPANT LOAD
XXX ROOM NUMBER
ROOM NAME
ROOM NAME
APPLICABALE CODES - UFC 1-200-01
CODE TITLE EDITION
BUILDING INTERNATIONAL BUILDING CODE 2015
ACCESSIBILITY ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS
MECHANICAL INTERNATIONAL MECHANICAL CODE 2015
ELECTRICAL NFPA 70, NATIONAL ELECTRIC CODE
PLUMBING INTERNATIONAL PLUMBING CODE 2015
FIRE PREVENTION NFPA 1, FIRE CODE
FUEL GAS NFPA 54, NATIONAL FUEL CODE
LIFE SAFETY NFPA 101 LIFE SAFETY CODE 2015
ENERGY INTERNATIONAL ENERGY CONSERVATION CODE 2015
BUILDING DESIGN CRITERIA
OCCUPANCY: B - BUSINESS (PRIMARY)
S-1 - STORAGE, SEE PLANS FOR LOCATION
A-3 - ASSEMBLY, SEE PLANS FOR LOCATION
F-1 - FACTORY, SEE PLANS FOR LOCATION
OCCUPANCY SEPARATION: B/S-1 = NO SEPARATION REQUIREMENT
B/F-1 = NO SEPARATION REQUIREMENT
B/A = 1 HR.
TYPE OF CONSTRUCTION: II-B (TYPE 2, NON-RATED) (IBC)
II-000 (NFPA)
SPRINKLER SYSTEM: YES
SMOKE DETECTION SYSTEM: SPEAKER
FIRE ALARM SYSTEM: YES, WITH PULL STATIONS AND STROBES
VOICE/ALARM SYSTEM: YES
BUILDING AREA:
ACTUAL: LOWER LEVEL W/ OPTIONS: 19,383 + 8,348
MAIN LEVEL: 75,333 S.F.
ALLOWABLE: UNLIMITED.
BUILDING HEIGHT:
ACTUAL: 1 STORY (28')
ALLOWABLE: 3 STORIES (55')
MEANS OF EGRESS DESIGN CRITERIA
OCCUPANT LOAD FACTOR : BUSINESS AREAS = 100 GROSS
STORAGE AREAS AND MECHANICAL ROOMS = 300 GROSS
ASSEMBLY, STANDING SPACE = 15 GROSS
ASSEMBLY, WITH FIXED SEATS = # OF SEATS
KITCHENS, COMMERICAL = 200 GROSS
CLASSROOM/TRAINING AREA = 20 NET
INDUSTRIAL = 100 GROSS
EXERCISE AREAS = 50 GROSS
LOCKER ROOMS - 50 GROSS
OCCUPANT LOAD: BASEMENT: 152 W/ OPTIONS: 224
MAIN LEVEL: 1,121 W/ OPTIONS: 1,193
TOTAL: 1,273 W/ OPTIONS: 1,410
STAIRWAY EGRESS WIDTH: 0.2 INCHES/OCCUPANT
DOOR EGRESS WIDTH: 0.15 INCHES/OCCUPANT
EXIT ACCESS TRAVEL DISTANCE: 250'
COMMON PATH OF TRAVEL: SHALL NOT EXCEED 100'
CODE REVIEW SYMBOLS LEGEND
GENERAL INFORMATION
LOCATION OF PROJECT: 25TH AND CAPEHART ROAD, BELLEVUE, NE
REFER TO THIS SHEET FOR INDIVIDUAL ROOM OCCUPANT LOADS
TOILET FIXTURE CALCULATIONS
PLUMBING FIXTURES: MINIMUM NUMBER SHALL BE CALCULATED BASED ON FACILITY OCCUPANT
LOAD OF 1,410 MAX. OCCUPANTS AT 60% MALES AND 40% FEMALES OR 846 MALES AND 564
FEMALES.
REQUIRED/PROVIDED
WATER CLOSET: FEMALES = 11/11 (INCLUDES 2 SINGLE USER RESTROOMS)
MALES = 15/15 (INCLUDES 2 SINGLE USER RESTROOMS)
(INCLUDES 7 URINAL SUBSTITUTIONS)
URINALS: 7 PROVIDED, CAN SUBSTITUTE FOR W/C AS FOLLOWS:
ASSEMBLY - 67% OF REQ. (4.37 x 67% = 2.92 =2) ALL OTHER OCCUPANCIES - 50% OF REQ. (10 x 50% = 5)
TOTAL SUBSTITUTIONS ALLOWED = 7
DRINKING FOUNTAINS: 9/9
LAVATORIES: FEMALES = 7/10 (INCLUDES 2 SINGLE USER RESTROOMS)
MALES = 9/13 (INCLUDES 2 SINGLE USER RESTROOMS)
SERVICE SINKS: 1
FIRE RESISTANCE RATINGS OF BUILDING ELEMENTS
ELEMENT RATINGS
PRIMARY SRUCTURAL FRAME 0 HOURS
EXTERIOR BEARING WALLS 0 HOURS
INTERIOR BEARING WALLS 0 HOURS
EXTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOURS
INTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOURS
FLOOR CONSTR. AND ASSOC. SECONDARY MEMEBERS 0 HOURS
ROOF CONSTR. AND ASSOC. SECONDARY MEMBERS 0 HOURS
XXX
OCCUPANCY LOAD FACTOR
ASSEMBLY
CLASSROOM/
LECTURE
FAMILY
READINESS
RECRUITING
LEARNING
CENTER
DISPLAY
101A
LACTATION
LOCKERS
BREAK /
VENDING
TRAINING
ELEC
107A
VEST
MECH / WATER
SERVICE
ANTE
105A
ANTE
105B
ELEC
157D
PHYSICAL
FITNESS
MEN
110WOMEN
ISSUING
BEVERAGES
158B
MEDICAL
TABLE / CHAIR
STORAGE
104A
KITCHEN
160 SERVING
158A
LOBBY / MAIN
HALL
CORR
CORR
ELEC
IT
VAULT
153A
ARMORER
ISSUING
ISSUING
152.1
WOMEN
LOCKERS
108A
MEN LOCKERS
110A
MECH
IT
157C
ELEC
CUST
IT
PANTRY /
OFFICE
160D
CUST
160C
TOILET
160B
SCULLERY
160A
CORR
157B
CORR
157A
CORR
CORR
101CALCOVE
101B
ALCOVE
101D
LIFT EQUIP
105C
MEN SHOWERS
110B
WOMEN
SHOWERS
108B
TOILET
CONF
OFFICE
OFFICE
WORK RM
OPEN OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CONF
OFFICE
OFFICE
MECH
WORK RM
OPEN OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CLASSROOM
CLASSROOM
MECH
EXIT
# OF SEATS
100 4
6 3
138 SF
119 SF
ISSUING
157E
E X
IT
E X
IT
EXIT
E X
IT
EXIT
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
CORR
101E
ELEV LOBBY /
STAIR
101F
HEATED
STORAGE
E X
IT
5'
10.5'
59'
25.5'
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FEC
FECFEC
FEC
FEC
FE
FEC
A-704
SHEET NUMBER
SHEET TITLE
CLIENT INFORMATION
PROJECT INFORMATION
JOB #
ISSUE DATE
Checked by Drawn by
Davis Design All Rights Reserved
E a s t
M a in
S u it e
V e rm ill io n S
D
P h o n e
-6
-1
V e rm il li o n
N S tr e e t, S u it e
L in c o ln N
E
P h o
-4
-9
F a x
-4
-9
L in c o ln L in c o ln
N th
S tr e e t, S u it e
O m a h a
N E
-4
-3
W a rd
P a rk w a y
K a n s a s C it y
M O
-3
-9
D
R e v it
L o c a l2
\1
-0
-A
IS
V
R C d a n .w a rn e r6
R
A Q
.r v t
/2
/2
:4 : 5
P
M
Nebraska National Guard
Bellevue Readiness Center S. 25th and Capehart Rd., Bellevue, NE
G-101
Regulatory Plans - Main Level
18-0060
02/25/21
BS
DW
1/16" = 1'-0"
MAIN LEVEL FLOOR PLAN
Revisions
ID Date Description
CORR
CST STORAGE
STAIR
CONF
CST LOG / ADMIN
08A
MECH
CORR
ELEC
FLAMMABLE
STORAGE
RECEIVING
CORR
IT
CST READY
BAYS
CUST
TOILET
TOILET
OFFICE
36A
CST SURVEY
CST COMMO
OFFICE
29A
CST MED
SUPPORT
OFFICE
28A
CST MED STOR
36B
IT
ELEC
CST
OPERATIONS
OFFICE
29B
OFFICE
28B
CST COMMAND
OFFICE
28C MECH
ELEV EQUIP
GROUNDS &
MAINTENANCE
TRAINING AID
STORAGE
29C
100 2
PLUMBING
CHASE
30E
CORRIDOR
624 SF
CORRIDOR
7B
164 SF
HALL
276 SF
STAIR
BASE=RMB-1
CLNG=ACP-1
FLOOR=CONC-1
194 SF
CORRIDOR
7A
BASE=VB-1
CLNG=ACP-1 / GWB, P-1
FLOOR=CONC-1
FEC
FEC
FEC
FE
A-407 9
XX
OCCUPANT LOAD:
INDICATES THE OCCUPANCY OF
ROOM OR SPACE BASED ON
TABULAR LOAD FACTOR
OCCUPANCY LOAD FOR ROOM OR
SPACE
AGGREGATE LOAD:
TOTAL LOAD OF SPACE INCLUDING ALL
LOADS FROM OTHER SPACES
EXIT:
INDICATES LOAD AT EXIT
AND EXIT WIDTH
REQUIREMENTS
EXIT DOOR WIDTH REQUIRED (IN
INCHES) PER TABLE 1005.1
OCCUPANT LOAD
EXIT WIDTH PROVIDED (IN INCHES)
XX
XX
XX
XX
REGULATORY INFORMATION
ROOM SQUARE FOOT AREAXXX SF
1-HOUR FIRE BARRIER (OCCUPANCY AND EGRESS SEPARATION)
2-HOUR SHAFT WALL
SMOKE PARTITION
WALL MOUNTED FIRE EXTENGUISHER ON WALL BRACKET, BY OTHERS
FIRE EXTENGUISHER CABINET (FIRE EXTINGUISHER BY OTHERS)FEC
FE
ACCUMULATED OCCUPANT LOAD
XXX ROOM NUMBER
ROOM NAME
ROOM NAME
APPLICABALE CODES - UFC 1-200-01
CODE TITLE EDITION
BUILDING INTERNATIONAL BUILDING CODE 2015
ACCESSIBILITY ARCHITECTURAL BARRIERS ACT (ABA) STANDARDS
MECHANICAL INTERNATIONAL MECHANICAL CODE 2015
ELECTRICAL NFPA 70, NATIONAL ELECTRIC CODE
PLUMBING INTERNATIONAL PLUMBING CODE 2015
FIRE PREVENTION NFPA 1, FIRE CODE
FUEL GAS NFPA 54, NATIONAL FUEL CODE
LIFE SAFETY NFPA 101 LIFE SAFETY CODE 2015
ENERGY INTERNATIONAL ENERGY CONSERVATION CODE 2015
BUILDING DESIGN CRITERIA
OCCUPANCY: B - BUSINESS (PRIMARY)
S-1 - STORAGE, SEE PLANS FOR LOCATION
A-3 - ASSEMBLY, SEE PLANS FOR LOCATION
F-1 - FACTORY, SEE PLANS FOR LOCATION
OCCUPANCY SEPARATION: B/S-1 = NO SEPARATION REQUIREMENT
B/F-1 = NO SEPARATION REQUIREMENT
B/A = 1 HR.
TYPE OF CONSTRUCTION: II-B (TYPE 2, NON-RATED) (IBC)
II-000 (NFPA)
SPRINKLER SYSTEM: YES
SMOKE DETECTION SYSTEM: SPEAKER
FIRE ALARM SYSTEM: YES, WITH PULL STATIONS AND STROBES
VOICE/ALARM SYSTEM: YES
BUILDING AREA:
ACTUAL: LOWER LEVEL W/ OPTIONS: 19,383 + 8,348
MAIN LEVEL: 75,333 S.F.
ALLOWABLE: UNLIMITED.
BUILDING HEIGHT:
ACTUAL: 1 STORY (28')
ALLOWABLE: 3 STORIES (55')
MEANS OF EGRESS DESIGN CRITERIA
OCCUPANT LOAD FACTOR : BUSINESS AREAS = 100 GROSS
STORAGE AREAS AND MECHANICAL ROOMS = 300 GROSS
ASSEMBLY, STANDING SPACE = 15 GROSS
ASSEMBLY, WITH FIXED SEATS = # OF SEATS
KITCHENS, COMMERICAL = 200 GROSS
CLASSROOM/TRAINING AREA = 20 NET
INDUSTRIAL = 100 GROSS
EXERCISE AREAS = 50 GROSS
LOCKER ROOMS - 50 GROSS
OCCUPANT LOAD: BASEMENT: 152 W/ OPTIONS: 224
MAIN LEVEL: 1,121 W/ OPTIONS: 1,193
TOTAL: 1,273 W/ OPTIONS: 1,410
STAIRWAY EGRESS WIDTH: 0.2 INCHES/OCCUPANT
DOOR EGRESS WIDTH: 0.15 INCHES/OCCUPANT
EXIT ACCESS TRAVEL DISTANCE: 250'
COMMON PATH OF TRAVEL: SHALL NOT EXCEED 100'
CODE REVIEW SYMBOLS LEGEND
GENERAL INFORMATION
LOCATION OF PROJECT: 25TH AND CAPEHART ROAD, BELLEVUE, NE
REFER TO THIS SHEET FOR INDIVIDUAL ROOM OCCUPANT LOADS
TOILET FIXTURE CALCULATIONS
PLUMBING FIXTURES: MINIMUM NUMBER SHALL BE CALCULATED BASED ON FACILITY OCCUPANT
LOAD OF 1,410 MAX. OCCUPANTS AT 60% MALES AND 40% FEMALES OR 846 MALES AND 564
FEMALES.
REQUIRED/PROVIDED
WATER CLOSET: FEMALES = 11/11 (INCLUDES 2 SINGLE USER RESTROOMS)
MALES = 15/15 (INCLUDES 2 SINGLE USER RESTROOMS)
(INCLUDES 7 URINAL SUBSTITUTIONS)
URINALS: 7 PROVIDED, CAN SUBSTITUTE FOR W/C AS FOLLOWS:
ASSEMBLY - 67% OF REQ. (4.37 x 67% = 2.92 =2) ALL OTHER OCCUPANCIES - 50% OF REQ. (10 x 50% = 5)
TOTAL SUBSTITUTIONS ALLOWED = 7
DRINKING FOUNTAINS: 9/9
LAVATORIES: FEMALES = 7/10 (INCLUDES 2 SINGLE USER RESTROOMS)
MALES = 9/13 (INCLUDES 2 SINGLE USER RESTROOMS)
SERVICE SINKS: 1
FIRE RESISTANCE RATINGS OF BUILDING ELEMENTS
ELEMENT RATINGS
PRIMARY SRUCTURAL FRAME 0 HOURS
EXTERIOR BEARING WALLS 0 HOURS
INTERIOR BEARING WALLS 0 HOURS
EXTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOURS
INTERIOR NON-BEARING WALLS AND PARTITIONS 0 HOURS
FLOOR CONSTR. AND ASSOC. SECONDARY MEMEBERS 0 HOURS
ROOF CONSTR. AND ASSOC. SECONDARY MEMBERS 0 HOURS
XXX
OCCUPANCY LOAD FACTOR
100 2
467 SF
OFFICE
640 SF
OFFICE
CORRIDOR
7C
6410 SF
GPTB BAY
99 SF
HALL
FE
A-903
A-903
A-903
A-903
A-9035
SHEET NUMBER
SHEET TITLE
CLIENT INFORMATION
PROJECT INFORMATION
JOB #
ISSUE DATE
Checked by Drawn by
Davis Design All Rights Reserved
E a s t
M a in
S u it e
V e rm ill io n S
D
P h o n e
-6
-1
V e rm il li o n
N S tr e e t, S u it e
L in c o ln N
E
P h o
-4
-9
F a x
-4
-9
L in c o ln L in c o ln
N th
S tr e e t, S u it e
O m a h a
N E
-4
-3
W a rd
P a rk w a y
K a n s a s C it y
M O
-3
-9
D
R e v it
L o c a l2
\1
-0
-A
IS
V
R C d a n .w a rn e r6
R
A Q
.r v t
/2
/2
:4 : 0
P
M
Nebraska National Guard
Bellevue Readiness Center S. 25th and Capehart Rd., Bellevue, NE
G-102
Regulatory Plans - Lower Level
18-0060
02/25/21
BS
DW
1/16" = 1'-0"
LOWER LEVEL FLOOR PLAN
1/16" = 1'-0"
LOWER LEVEL CODE FLOOR PLAN WITH ABI
Revisions
FORWARD APPROACH SIDE APPROACH
CLEAR FLOOR SPACE LEVEL CHANGE
BEVELED CHANGE IN LEVEL
VERTICAL CHANGE IN LEVEL
PASSAGE WIDTHS
TWO WHEELCHAIRS ONE WHEELCHAIR
AND ONE
AMBULATORY
PERSON
SINGLE
WHEELCHAIR T-SHAPED TURNING SPACE
TURNING SPACE
CIRCULAR TURNING SPACE
FORWARD APPROACH
SIDE APPROACH
ALCOVE CLEARANCE
PLAN SECTION
CLEAR
FLOOR
SPACE
SINK, LAVATORY
OR OTHER
OBJECT TO ROLL
UNDER
SINK, LAVATORY
OR OTHER
OBJECT TO ROLL
UNDER
CIRCULATION PATH
MOUNTED ON
POST OR PYLON
MOUNTED ON
POSTS OR PYLONS
GUARDRAIL OR
OTHER BARRIER
LEG CLEARANCES
PROTRUDING OBJECTS
VERTICAL CLEARANCE
FORWARD REACH SIDE REACH
FORWARD REACH
OVER OBSTRUCTION
SIDE REACH
OVER OBSTRUCTION
REACH LIMITS
APPROACH
APPROACH
12" IF DOOR HAS
CLOSER & LATCH
NOTE: ENTRY DOORS TO ACUTE
CARE HOSPITAL BEDROOMS FOR
INPATIENTS SHALL BE EXEMPTED
FROM SPACE REQUIRED AT
LATCH SIDE OF DOOR IF THE
DOOR IS AT LEAST 44" WIDE
DOOR CLEARANCE
PULL SIDE
PUSH
SIDE
PULL SIDE
PUSH
SIDE
PULL SIDE
PUSH
SIDE
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
A P
P R
O A
C H
NOTE: ENTRY DOORS TO ACUTE
CARE HOSPITAL BEDROOMS FOR
INPATIENTS SHALL BE EXEMPTED
FROM SPACE REQUIRED AT
LATCH SIDE OF DOOR IF THE
DOOR IS AT LEAST 44" WIDE
DOOR CLEARANCE
X = 36" MIN. IF Y = 60"
X = 42" MIN. IF Y = 54"
NOTE: ENTRY DOORS TO ACUTE
CARE HOSPITAL BEDROOMS FOR
INPATIENTS SHALL BE EXEMPTED
FROM SPACE REQUIRED AT
LATCH SIDE OF DOOR IF THE
DOOR IS AT LEAST 44" WIDE
DOOR CLEARANCE
A P
P R
O A
C H
APPROACH
NOTE: FRONT APPROACH
CLEARANCES ARE THE
SAME FOR POCKET,
ACCORDION, SLIDING AND
OTHER NON-SWINGING
DOORS.
DOOR CLEARANCE
PULL SIDE
PUSH
SIDE
APPROACH
APPROACH
12" IF DOOR HAS
CLOSER & LATCH
NOTE: ENTRY DOORS TO ACUTE
CARE HOSPITAL BEDROOMS FOR
INPATIENTS SHALL BE EXEMPTED
FROM SPACE REQUIRED AT
LATCH SIDE OF DOOR IF THE
DOOR IS AT LEAST 44" WIDE
IF
IF
DOOR CLEARANCE
M
IN
M
IN
M
IN
.NOTE:
DIMENSIONS
ARE TO THE
FACE OR EDGE
OF DOOR
DOORS IN SERIES
<4"
RAMP & LANDING
TRANSITION
EDGE OF RAMP OR
LANDING
SLOPE ≤ 1:48
RAMPS
STAIR SECTION
CURVED
NOSING
BEVELED
NOSING
TREAD EDGE
(TYP. FOR
ALL
PROFILES)
ANGLED
RISER
1/2"
RADIUS
MAX.
30° MAX.
1 1/2" MAX. 1 1/2" MAX.
1 1/2" MIN.
/2
M
IN
HANDRAIL
SECTION
STAIR & HANDRAILS
NOTE:
SHALL COMPLY W/
REQUIRED KNEE & TOE
CLEARANCES
DRINKING FOUNTAIN
16"-18" WHEELCHAIR
ACCESSIBLE
17"-19" AMBULATORY
ACCESSIBLE
NOTE:
THE WATER CLOSET, GRAB BARS,
DISPENSERS, SANITARY NAPKIN
DISPOSAL UNITS, COAT HOOKS,
SHELVES MAY OVERLAP THE
REQUIRED CLEARANCE AROUND THE
WATER CLOSET. NO OTHER
FIXTURES OR OBSTRUCTIONS SHALL
BE LOCATED WITHIN THE REQUIRED
WATER CLOSET CLEARANCE.
NOTE:
EXCEPTIONS APPLY TO RESIDENTIAL
DWELLING UNITS, SEE GUIDELINES
FOR DETAILS.
TOILET CLEARANCES
NO PROTRUDING
OBJECTS
1 1/2" 1 1/2"
/2
GRAB BARS
T O
T O
P
F
S
E A
T
TOILET CLEARANCES
ALTERNATE
DOOR
LOCATION
A P
P R
O A
C H
A P
P R
O A
C H
F O
R W
A L L -H
U N
G
T
IL
E
T
F
R
L O
O R
M O
U N
T
D
IL
E
T
C
H
IL
D R
E N
'S T
O
IL
E T
WHEELCHAIR ACCESIBLE AMBULATORY ACCESIBLE TOE CLEARANCES
35"-37"
T O
E C
L E
A R
A N
C E
R E
Q 'D
U
N L E
S S
C O
M P
A R
T M
E N
T
IS
M
IN
D
E E
P W
IT
H
W A
L L H
U N
G T
O
IL
E T
O R
M
IN
D
E E
P W
IT
H
F L O
O R
M O
U N
T E
D T
O
IL
E T
O
R C
H
IL
D R
E N
'S T
O
IL
E T
6" TOE CLEARANCE
REQUIRED UNLESS
COMPARTMENT IS
66" MIN. WIDE
TOILET COMPARTMENTS
NOTE:
SHALL COMPLY W/ DRAWINGS CLEAR FLOOR
SPACE AND LEG CLEARANCES ON THIS SHEET.
13 1/2"
MIN.
WALL HUNG
TYPE
T O
C O
N T
R O
L S
M A
X
IF
U
R
IN
A L I S
L E
S S
T H
A N
D E
E P
M A
X I
U
IN
A L I S
B E
T W
E E
N
A N
D
D E
E P
M A
X
URINAL CLEARANCES
/2
M A
X
S E
TRANSFER SHOWER
M A
X
1/2"
MAX.
CONT
-ROLS
SHOWER CLEARANCES
NOTE:
THIS DRAWING IS INCLUDED TO PROVIDE GENERAL
INFORMATION TO THE CONTRACTOR IN REGARD TO
THE AMERICANS WITH DISABILITIES ACT OF 2010.
THE DRAWINGS CONTAINED ON THIS SHEET ARE
NOT SPECIFIC LAYOUTS OR DETAILS OF THE
ACTUAL ROOMS SHOWN ON SUBSEQUENT
DRAWINGS IN THIS SET BUT ARE TO BE USED FOR
REFERENCE WHERE APPLICABLE.
CONTRACTOR TO COMPLY WITH ALL SECTIONS OF
THE NEBRASKA ACCESSIBILITY GUIDELINES (NAG).
ALL DOORS, HARDWARE AND CLOSERS SHALL BE
ADJUSTED BEFORE OCCUPANCY TO MEET NAG
4.13.10, 4.13.11, 4.13.12.
TYPICAL SHOWER
ELEVATION WITH A
SEAT
GRAB BARS AS
INDICATED ON
PLAN
CONTROLS, WHERE
INDICATED ON PLAN
CL
TOILET PARTITION
AS INDICATED
59" FLOOR MTD. TLT.
56" WALL MTD. TLT.
PAPER
TOWEL (&
TRASH)
RECEPTACLE
ELECTRIC
HAND
DRYER
SOAP
DISPENSER
MIRROR COAT
HOOK
BABY
CHANGIN
G
STATION
SHELF SANITARY
NAPKIN
DISPOSAL
SANITARY
NAPKIN
DISPENSER
ADA
RESTROOM
SIGNAGE
SHOWER
CURTAIN
ROD
M A
X
M A
X
M A
X
S U
R F
A C
E
M A
X
B .O
R
E F
L E
C T
IN
G
O P
E N
P O
S
IT
IO
N
M A
X
IN
C O
N T
R O
L S
M A
X
M A
X
CL
ACCESSORY MOUNTING HEIGHTS
TOILET
TISSUE
DISPENSER
7"-9"
M
IN
30" MIN.
M
IN
48" MIN.
/4
/4
/4
/2
M
A X
60" MIN. 48" MIN.
32" MIN.
36" MIN.
M A
X
12" 36" 12"
60"
60" DIA.
36" MIN.
60" MIN.
X
X
4" MAX.
IF
H
E
IG
H T
H E
IG
H
T
12" 12"
IF
H
E
IG
H T
H
E
IG
H T
IF > 12"
M A
X
IF > 12"
M
IN
M A
X
IF
H
E
IG
H T
T O
12" MIN.
12" MIN.
IS
R
E Q
'D
IF
H A
N D
R A
IL
12" MIN.
T O
TR.
TR.
5" MAX. 15" MIN.
M
IN
.4
M A
X
10" MAX.
M
IN
M A
X
X
H E
IG
H
T
M A
X
IF
X
H E
IG
H
T
M A
X
IF
X
M A
X
MAX.
10" TO 24"
18" 18"
24"
24"
W
C L O
S E
R
W /O
C L O
S E
R
W /O
C L O
S E
R
W
C L O
S E
R
Y
X
22"
L
A T
C H
W /O
C L O
S
L
A T
C H
W
C L O
S E
R
M
IN
32" MIN.
M
IN
60" MIN.
M A
X
4" MAX.
M
IN
M
IN
M
IN
12" 24" MIN. 5
M
IN
60" MIN.
M
IN
M A
X
M
IN
30" MIN.
M A
X
M
IN
8" MIN.
11" MIN.
17"-25" MAX.
6" MAX.
M
IN
MAX.
15"
M
IN
M A
X
18"
36"
M
IN
22"-23"
15"-16"
12" MIN.
48" MIN.
SHEET NUMBER
SHEET TITLE
CLIENT INFORMATION
PROJECT INFORMATION
JOB #
ISSUE DATE
Checked by Drawn by
Davis Design All Rights Reserved
E a s t
M a in
S u it e
V e rm ill io n S
D
P h o n e
-6
-1
V e rm il li o n
N S tr e e t, S u it e
L in c o ln N
E
P h o
-4
-9
F a x
-4
-9
L in c o ln L in c o ln
N th
S tr e e t, S u it e
O m a h a
N E
-4
-3
W a rd
P a rk w a y
K a n s a s C it y
M O
-3
-9
D
R e v it
L o c a l2
\1
-0
-A
IS
V
R C d a n .w a rn e r6
R
A Q
.r v t
/2
/2
:4 : 0
P
M
Nebraska National Guard
Bellevue Readiness Center S. 25th and Capehart Rd., Bellevue, NE
G-103
Abbreviations &
2010 ADA
Accessibility Standards
18-0060
02/25/21
BS
DW
ABBREVIATIONS:
1/4" = 1'-0"
ACCESSIBILITY STANDARD 2010 ADA
Revisions
SHEET NUMBER
SHEET TITLE
CLIENT INFORMATION
PROJECT INFORMATION
JOB #
ISSUE DATE
Checked by Drawn by
Davis Design All Rights Reserved
E a s t
M a in
S u it e
V e rm ill io n S
D
P h o n e
-6
-1
V e rm il li o n
N S tr e e t, S u it e
L in c o ln N
E
P h o
-4
-9
F a x
-4
-9
L in c o ln L in c o ln
N th
S tr e e t, S u it e
O m a h a
N E
-4
-3
W a rd
P a rk w a y
K a n s a s C it y
M O
-3
-9
D
R e v it
L o c a l2
\1
-0
-A
IS
V
R C d a n .w a rn e r6
R
A Q
.r v t
/2
/2
:4 : 0
P
M
Nebraska National Guard
Bellevue Readiness Center S. 25th and Capehart Rd., Bellevue, NE
G-104
Survey
18-0060
02/25/21
Others Others
Revisions
ID Date Description
A l f r e d
B e n e s c h o m p a n y
M t r e e t
S u i t
L i n c o l n
N e b r a s k a
PROJECT
DATE
SHEET
N O
R E V
IS
IO
N S
D A T E
January 12, 2021
S
T
H
S
T R
E E
P
E H
A R
T
R
O
D
B
L
L E
V U
E
N
E
111797.00
J o b
N o
T O
P O
G R
A P
H I
U R
V E
Y
NOTE: This survey was prepared by others and is included to show conditions prior to the contractor entering the site. Field verify existing conditions.
| G-100.1 - Cover Page -Volume 1 |
| G-101 - Regulatory Plans -Main Level |
| G-102 - Regulatory Plans -Lower Level |
| G-103 - Abbreviations & 2010 ADA Accessibility Standards |
| G-104 - Survey |