B08_Attach 3 Exhibit 4 Dwg_Emergency Repair of Roof_2011.pdf
PDF 6 MB Posted
- Solicitation number
- 140P2020R0158
About this file
This document package includes construction drawings and specifications for emergency repair work on the roof and water damage at Building #2, the Steel Visitor Center, at Crater Lake National Park. The drawings show plans for foundation work, first and second floor renovations, roof repairs, and flashing and window details. Repairs are needed due to water damage at dormers and other areas. Work includes patching plaster, repairing water damage, and reinstalling removed elements like light fixtures and shelving. Shoring is required for column installation. The related federal contract opportunity is solicitation number 140P2020R0158 from the National Park Service for structural deficiency corrections and stabilization of the Steel Visitor Center under project number CRLA 198641. The opportunity involves construction services to repair the building's structural issues and water damage according to the provided drawings and specifications.
View the file
Other files
Show all 35
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
OF
PKG.
NO.
SHEET
DRAWING NO.
TITLE OF PROJECT
COUNTY STATEREGION
PACIFIC WEST OREGON
UNITED STATES
DEPARTMENT OF THE INTERIOR
NATIONAL PARK SERVICE
InitialDateREVISIONMark SheetQUALITY DESIGN CERTIFICATION
OR
OR
Project Manager Date
Prepared in Accordance with Design Development Title I _____________
Construction Drawing Not Preceded by Design Development (Title I)
Variance from Design Development (Title I) Approved by Superintendent on ___________ (Date)
C 8078 08-0177
SEPTEMBER 2011
171188
CRATER LAKE NATIONAL PARK
EMERGENCY REPAIR OF ROOF AND
WATER DAMAGE TO BUILDING #2
STEEL VISITOR CENTER
100% CONSTRUCTION
DOCUMENTS
PROJ. NO. CRLA 171188
TITLE OF SHEET SUB SHEET NO.DESIGNED:
DRAWN BY:
DATE:
KLAMATH
109418
T H I S P R O J E C T
T O B E N D N O R T H E N T R A N C E
C L O S E D D U R I N G W I N T E R
T O
M E
D F
O R
D W
E S
T E
N T
R A
N C
E
S O U T H E N T R A N C E T O K L A M A T H F A L L S
C R A T E R L A K E
P A R K H D Q T R .
C R A T E R L A K E N A T I O N A L P A R K
1A-1
DLL
MKD
08/24/11
COVER SHEET
SITE PLAN
SCOPE OVERVIEW
SHEET INDEX
SCALE OF FEET
800 1600
SCALE OF FEET
20 40
SCALE A
SCALE B
SHEET INDEX:
ID NAME
A-1 COVER SHEET
VICINITY MAP
GENERAL NOTES
SHEET INDEX
A-2 FOUNDATION PLAN
A-3 1ST FLOOR PLAN
A-4 2ND FLOOR PLAN
A-5 ROOF PLAN
A-6 WINDOW AND FLASHING DETAILS
S-1 STRUCTURAL NOTES
S-2 SHORING FOUNDATION PLAN
S-3 SECOND FLOOR SHORING PLAN
S-4 SHORING DETAILS
L
NFPA NAT’L FIRE
PROTECTION
ASSOC.
NIC NOT IN CONTRACT
NOM NOMINAL
NTS NOT TO SCALE
O/ OVER
OA OVERALL
OC ON CENTER
OCC OCCUPANTS
OD OUTSIDE DIAMETER
OPNG OPENING
OPP OPPOSITE
OSB ORIENTED STRAND
BOARD
PARA PARALLEL
PERP PERPENDICULAR
PL PLATE
PLAS PLASTER
PLYWD PLYWOOD
PR PAIR
PT PAINT
PTN PARTITION
(R) REMOVE
RAD RADIUS
RB RUBBER BASE
RD ROOF DRAIN
REC RECESSED
REF REFINISH
REINF REINFORCE
REP REPAIR
REQ REQUIRED
RESIL RESILIENT
RES RESTORE
RF REFERENCE
RGTR REGISTER
RL ROOF LEADER
RM ROOM
S SOUTH
SALV SALVAGE
SC SOLID CORE
SCHED SCHEDULE
SECT SECTION
SF SQUARE FEET
SHT SHEET
SHTHG SHEATHING
ABBREVIATIONS:
SIM SIMILAR
SL SEAL
SLR SEALER
SPEC SPECIFICATION
SQ SQUARE
SST STAINLESS STEEL
ST STAIN
STA STATION
STD STANDARD
STL STEEL
STOR STORAGE
STRUC STRUCTURAL
SUSP SUSPENDED
SYM SYMMETRICAL
T&G TONGUE & GROOVE
THK THICK
T.O. TOP OF
TOC TOP OF CURB
TOP TOP OF PAVEMENT
TR TRASH RECEPTACLE
TRD TREAD
TOW TOP OF WALL
TYP TYPICAL
UMC UNIFORM MECHANICAL
CODE
UNF UNFINISHED
UON UNLESS OTHERWISE
NOTED
UPC UNIFORM PLUMBING
CODE
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VTR VENT THRU ROOF
W WEST
W/ WITH
WCV WALL-COVERING
WD WOOD
WDW WINDOW
WO WHERE OCCURS
W/O WITHOUT
WP WATERPROOF
WT WEIGHT
GA GAUGE
GALV GALVANIZED
GL GLASS
GLB GLULAM BEAM
GND GROUND
GR GRADE
GSM GALVANIZED SHEET
METAL
GYP GYPSUM
GWB GYPSUM WALL
BOARD
HB HOSE BIBB
HC HOLLOW CORE
HDR HEADER
HDWD HARDWOOD
HDWR HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
HR HOUR
HT HEIGHT
IBC INTERNATIONAL BUILDING
CODE
ID INSIDE DIAMETER
INSUL INSULATION
INT INTERIOR
JCT JUNCTION
LB POUND
LT LIGHT
MAX MAXIMUM
MB MACHINE BOLT
MECH MECHANICAL
MEMB MEMBRANE
MTL METAL
MFR MANUFACTURER
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MTD MOUNTED
MTL METAL
MUL MULLION
N/A NOT APPLICABLE
N NORTH
(N) NEW
MATERIAL LEGEND:
BLOCKING
WOOD FRAMING
PLYWOOD
STEEL
GYPSUM WALL BOARD
& AND
L ANGLE
@ AT
C CENTERLINE
# POUND
AD AREA DRAIN
ADJ ADJACENT
AFF ABOVE FINISHED
FLOOR
AL ALUMINUM
APPROX APPROXIMATE
ARCH ARCHITECTURAL
ASPH ASPHALT
ATT ATTACH
BD BOARD
BITUM BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
B.O. BOTTOM OF
BOT BOTTOM
BUR BUILT UP ROOFING
CB CATCH BASIN
CEM CEMENT
CER CERAMIC
CVG CLEAR VERTICAL
GRAIN
CJ CONTROL JOINT
CL CENTERLINE
CLG CEILING
CLKG CAULKING
CLO CLOSET
CLR CLEAR
CO CLEANOUT
COL COLUMN
COMP COMPOSITION
CONC CONCRETE
COND CONDITION
CONN CONNECTION
CONSTR CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACTOR
CORR CORRUGATED
CPT CARPET
CTR CENTER
CTSK COUNTERSINK
DBL DOUBLE
DEMO DEMOLITION
DET DETAIL
DF DOUGLAS FIR
DFPT PRESSURE TREATED
DOUGLAS FIR
DIA DIAMETER
DIM DIMENSION
DN DOWN
DO DOOR OPENING
DR DOOR
DS DOWNSPOUT
DSP DRY STANDPIPE
DTL DETAIL
DWG DRAWING
E EAST
(E) EXISTING
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
EMER EMERGENCY
ENCL ENCLOSURE
EP ELECTRICAL
PANEL
EQ EQUAL
EQPT EQUIPMENT
EWC ELECTRIC WATER
COOLER
EXIST EXISTING
EXP EXPANSION
EXPO EXPOSED
EXT EXTERIOR
FA FIRE ALARM
FB FUSE BOX
FBRGL FIBERGLASS
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER
CABINET
FHC FIRE HOSE CABINET
FIN FINISH
FLR FLOOR
FLASH FLASHING
FLUOR FLUORESCENT
FO FACE OF
FOC FACE OF CONCRETE
FOF FACE OF FINISH
FOM FACE OF MASONRY
FOS FACE OF STUD
FPRF FIREPROOF
FRP FIBERGLAS REINF
PANEL
FS FULL SIZE
FT FOOT OR FEET
FTG FOOTING
FURR FURRING
FUT FUTURE
1. CONTRACTOR SHALL VERIFY THAT (E) CONDITIONS ARE AS
INDICATED ON THE DRAWINGS. NOTIFY THE CONTRACTING
OFFICER IMMEDIATELY OF VARIATIONS OR DISCREPANCIES.
DO NOT PROCEED WITH AFFECTED WORK UNTIL THE
CONTRACTING OFFICER RESOLVES THE VARIATIONS AND/
OR DISCREPANCIES.
2. THE DRAWINGS SHOW PRINCIPAL AREAS OF WORK.
INCIDENTAL REMOVALS, RELOCATIONS, PATCHING AND
REPAIRING MAY ALSO BE NECESSARY IN AREAS. THIS
INCIDENTAL WORK, ALTHOUGH NOT NECESSARILY SHOWN
ON THE DRAWINGS IS ALSO PART OF THE CONTRACT.
ASCERTAIN THE WORK NEEDED, AND DO THAT WORK IN
ACCORD WITH THE CONTRACT REQUIREMENTS, AND AS
PART OF THE CONTRACT AMOUNT.
3. ALL CONSTRUCTION AND INSTALLATION WORK SHOWN ON
DRAWINGS SHALL BE DONE IN ACCORDANCE WITH ALL
APPLICABLE CODES AND ORDINANCES. USE METHODS AS
REQUIRED TO COMPLETE WORK WITHIN LIMITATIONS OF
ALL PREVAILING LAWS AND CODES.
4. DO NOT SCALE DRAWINGS: USE DIMENSIONS SHOWN. ALL
DIMENSIONS SHALL BE VERIFIED IN THE FIELD.
DIMENSIONS SHOWN AT (E) CONDITIONS ARE TO FACE OF
(E) FINISH UON. DIMENSIONS AT NEW WORK ARE TO FACE
OF FINISH UON. DIMENSIONS OF (E) CONDITIONS ARE FOR
REFERENCE ONLY AND SHALL BE VERIFIED BY THE
CONTRACTOR IN THE FIELD. WHERE NO DIMENSION IS
PROVIDED CONSULT WITH THE ARCHITECT FOR
CLARIFICATION BEFORE PROCEEDING WITH AFFECTED
WORK. ALL NOTED ITEMS ASSUMED NEW UNLESS NOTED
EXISTING OR (E).
5. SAFETY MEASURES: AT ALL TIMES THE CONTRACTOR
SHALL BE SOLELY RESPONSIBLE FOR THE CONDITIONS AT
THE JOB SITE, INCLUDING SAFETY OF PEOPLE AND
PROPERTY. ARCHITECT SITE VISITS ARE NOT INTENDED TO
REVIEW THE ADEQUACY OF THE CONTRACTOR’S SAFETY
MEASURES.
6. INSTALL MANUFACTURED MATERIALS AND EQUIPMENT PER
MANUFACTURER’S RECOMMENDATIONS AND
INSTRUCTIONS, UNLESS OTHERWISE INSTRUCTED.
7. ALL WASTE AND REFUSE CAUSED IN CONNECTION WITH
THE WORK SHALL BE REMOVED FROM THE PREMISES AND
DISPOSED OF BY THE CONTRACTOR. THE PREMISES SHALL
BE LEFT CLEAR AND CLEAN TO THE SATISFACTION OF NPS.
8. APPLICATION OF FINISH: SURFACES PREVIOUSLY
PREPARED OR INSTALLED BY ANOTHER TRADE SHALL BE
INSPECTED CAREFULLY BY THE CONTRACTOR BEFORE
APPLYING SUBSEQUENT MATERIALS OR FINISHES. IF
SURFACES ARE NOT ACCEPTABLE, CONTRACTING
OFFICER SHALL BE NOTIFIED IMMEDIATELY IN ORDER
THAT CORRECTIONS MAY BE MADE. APPLICATIONS OF
FINISHES WILL BE CONSTRUED AS ACCEPTANCE OF
RESPONSIBILITY BY THE SUBCONTRACTOR FOR THE BASE
UPON WHICH IT IS APPLIED.
9. INSTALL ALL WORK PLUMB, LEVEL AND STRAIGHT, OR AS
REQUIRED TO ALIGN WITH (E) ADJACENT SURFACES.
10. CONTRACTOR SHALL DESIGN AND INSTALL SHORING AS
REQUIRED TO PERFORM WORK. RESPONSIBILITY FOR
ENGINEERING, CONSTRUCTION AND SAFETY OF THE
SHORING SHALL BE THE RESPONSIBILITY OF THE
CONTRACTOR.
11. REFER TO SPECIFICATIONS FOR ADDITIONAL
INFORMATION. THE DRAWINGS AND SPECIFICATIONS ARE
INTENDED TO BE COMPLIMENTARY. SEE NOTE 12.
12. CONFLICTS BETWEEN VARIOUS ELEMENTS OF THE
DRAWINGS, SPECIFICATIONS, NOTES AND DETAILS SHALL
BE BROUGHT TO THE ATTENTION OF THE NPS
REPRESENTATIVE AND RESOLVED BEFORE PROCEEDING
WITH WORK.
13. DETAILS SHOWN SHALL BE INCORPORATED INTO THE
PROJECT AT ALL APPROPRIATE LOCATIONS WHETHER
SPECIFICALLY CALLED OUT OR NOT.
14. THE CONTRACTOR MUST SUBMIT IN WRITING ANY
REQUESTS FOR MODIFICATIONS TO THE PLANS AND THE
SPECIFICATIONS. SHOP DRAWINGS SUBMITTED TO THE
CONTRACTING OFFICER FOR REVIEW DO NOT
CONSTITUTE "IN WRITING" UNLESS IT IS CLEARLY NOTED
ON THE SUBMITTAL THAT SPECIFIC CHANGES ARE BEING
REQUESTED WITH THE PHRASE "REQUESTED CHANGE"
AND SUBMITTED WITH A COMPLETED SUBSTITUTION
REQUEST FORM.
15. FINAL AS-BUILT RECORD DOCUMENTS SHOWING ALL
REVISIONS INCORPORATED DURING CONSTRUCTION,
SHALL BE SUBMITTED TO THE CONTRACTING OFFICER
PRIOR TO PROJECT CLOSE-OUT.
DEMOLITION:
16. SAFETY OF THE PUBLIC, PERSONNEL AND PROPERTY
DURING THE DEMOLITION IS SOLELY THE RESPONSIBILITY
OF THE CONTRACTOR. BEFORE DEMOLITION BEGINS, THE
CONTRACTOR SHALL INSPECT THE (E) CONSTRUCTION TO
IDENTIFY DEFECTS AND STRUCTURAL WEAKNESSES
WHICH MAY AFFECT THE SAFETY OF HIS WORK.
CONTRACTOR SHALL TAKE APPROPRIATE MEASURES TO
ENSURE THAT THESE DEFECTS AND WEAKNESSES ARE
REMEDIED PRIOR TO PROCEEDING WITH DEMOLITION.
17. THE CONTRACTOR SHALL REVIEW THE NEED FOR
TEMPORARY BRACING PRIOR TO THE CUTTING AND
REMOVAL OF (E) CONSTRUCTION.
18. STRUCTURAL SHORING, WHERE REQUIRED, SHALL BE
REVIEWED FOR ADEQUACY TO MEET ITS INTENDED
PURPOSE BY THE CONTRACTOR’S OREGON STATE
LICENSED STRUCTURAL ENGINEER.
19. DURING DEMOLITION, PROTECT FROM DAMAGE ALL
MATERIALS NOT REQUIRED TO BE REMOVED OR
DEMOLISHED OR SPECIFICALLY NOTED TO BE
PROTECTED. CONTRACTOR TO SUBMIT DEMOLITION AND
PROTECTION PLAN FOR APPROVAL PRIOR TO
PROCEEDING WITH DEMOLITION.
20. REMOVE ALL MATERIALS ACCORDING TO OWNER’S
REQUIREMENTS.
21. RESTORE ADJACENT SURFACES DISTURBED BY
DEMOLITION TO ORIGINAL CONDITION. PATCH VISIBLE
SURFACES TO MATCH ADJACENT ORIGINAL FINISH
CONDITIONS.
22. REPAIR ALL FINISHES FOLLOWING REINSTALLATION OF
LIGHTING FIXTURES AND OTHER MISC EQUIPMENT, TYP.
23. PROTECT AND PREPARE FOR STORAGE BY THE PARK
BUILDING ELEMENTS REMOVED FOR PRESENT WORK TO
BE REINSTALLED DURING FINAL STABILIZATION.
SAND, GROUT, OR MORTAR
EARTH
GRAVEL
STRUCTURAL CONCRETE
BATT INSULATION
CONSTRUCTION TYPE: V A
SEISMIC ZONE: 2B
GROSS AREA SF SUMMARY:
BASEMENT/MECHANICAL ROOM 222 SF
FIRST FLOOR 2,765 SF
SECOND FLOOR 2,270 SF
GROSS AREA: 5,257 SF
PROJECT INFORMATION:
CODE INFORMATION:
ALL WORK SHALL COMPLY WITH APPLICABLE CODES
AND ORDINANCES INCLUDING BUT NOT LIMITED TO:
International Building Code, 2009 Edition International Existing Building Code, 2009 Edition Life Safety Code Occupational Safety and Health Act (OSHA, latest amended version).
National Historic Preservation Act (NHPA) Oregon Specialty Mechanical Code (OMSC) 2010 Oregon Electrical Specialty Code (OESC) 2011 Oregon Plumbing Specialty Code (OPSC) 2011
GENERAL NOTES:
PIPING:
DRAIN
PROPANE
ELECTRICAL
(E) DOMESTIC WATER
SANITARY SEWER
TELE/COM
FIRE
NON POTABLE WATER
SCALE C
04 4 8
SCALE OF FEET
012 12
SCALE OF INCHES
SCALE D
SCALE E
01 1 2
SCALE OF FEET
VICINITY MAP
NO SCALE
CRATER LAKE NATIONAL PARK
STEEL VISITOR CENTER
171188
DATE:
DESIGNED: SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
TITLE OF SHEET
TECH. REVIEW:
109418
2 3 4 5
B
C
D
E
G
F
A
E
D
C
B
G
A
F
2 3 4 5 61
HH
B.1B.1
B.2B.2
D.1D.1
D.2D.2
C-13 C-14 C-15 C-16
C-01 C-02
C-04C-03
C-05 C-07C-06
C-09
C-08
C-12 C-11 C-10
C-24C-23
C-22C-20
C-19
C-18
C-17 C-21
(E) LOAD BEARING
PONY WALL ALIGNMENT
(E) LOAD BEARING PONY
WALL ALIGNMENT
1 FOUNDATION PLAN N
DLL
MKD
08/24/11
A-2DLL
FOUNDATION PLAN
CSCALE
SCALE C
04 4 8
SCALE OF FEET
GENERAL NOTES:
1. COVER AND PROTECT AREAS ADJACENT TO AREA OF WORK.
2. DUCTWORK SHOWN IS SCHEMATIC ONLY. CONTRACTOR TO VERIFY ALL (E)
DUCTWORK LOCATIONS, ADJUST LOCATION OF DUCTS AS REQUIRED TO
ACCOMODATE (N) COLUMN BEARING LOCATIONS. NOTIFY OWNER AND
ARCHITECT OF ANY NECESSARY MODIFICATIONS BEFORE EXECUTION.
DOCUMENT ANY MODIFICATIONS ON RECORD DWGS.
STEEL VISITOR CENTER
171188
DATE:
DESIGNED: SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
TITLE OF SHEET
TECH. REVIEW:
109418
2 3 4 5
B
C
D
E
G
F
A
E
D
C
B
G
A
F
2 3 4 5 61
HH
B.1B.1
B.2B.2
D.1D.1
D.2D.2
'-1
0"
103'-1" +-
(E) CABINET TO REMAIN.
COVER & PROTECT
FROM DAMAGE
REMOVE (E) FALSE BEAM ABOVE.
WRAP & PROTECT FOR STORAGE BY
THE PARK FOR LATER REINSTALLATION
(E) SHELVING TO REMAIN. PROTECT FROM
DAMAGE. REMOVE DOORS & DRAWERS
ADJACENT TO CLMN. LOCATIONS
SUFFICIENT TO ALLOW FOR ACCESS.
WRAP & PROTECT FOR STORAGE BY NPS.
(E) CABINETS TO REMAIN PROTECT
FROM DAMAGE. REMOVE DOORS
ADJACENT TO COLUMN AS RQR'D FOR
ACCESS. WRAP, AND PROTECT FOR
PARK TO STORE UNTIL REINSTALLATION.
(E) GLASS COUNTERTOP
COVER AND PROTECT
FROM DAMAGE
CANTILEVER SHORING
BEAM TO WITHIN 2" OF FACE
OF STONE. PROTECT STONE
FROM DAMAGE.
REMOVE (E) FALSE BEAM ABOVE.
WRAP & PROTECT FOR STORAGE BY
OWNER FOR LATER REINSTALLATION.
PATCH & REPAIR WALL ADJACENT O
FIREPLACE. PROTECT BENCH BELOW.
SEE NOTE 2.
SEE NOTE 2.
SEE NOTE 2.
C-13 C-14 C-15 C-16
C-01 C-02
C-04C-03
C-05 C-07C-06
C-09
C-08
C-12 C-11 C-10
C-24C-23
C-22C-20
C-19
C-18
C-17 C-21
CRAWLSPACE
ACCESS
CRAWLSPACE
ACCESS
RELOCATE (E) LAV. TO
WEST TO ALLOW COL.
CLEARANCE - FIELD
VERIFY LOCATION
HW
(E) LOAD BEARING
PONY WALL ALIGNMENT
(E) LOAD BEARING PONY
WALL ALIGNMENT
TRASH
TERRACE
VISITOR
LOBBY
ENTRY
ASSOC. SALESVISITOR
INFO.PROJ.
STOR.
STAIR
AUDITORIUM
ROOM
OFFICE
WOMEN'S
ROOMMEN'S
ROOM
HALL
UTILITY
STOR.
ROOM
A
A
A
4'-6"
5'-4"
5'-5"
2x DOUBLE
HEADERS
(E) PLASTER CEILING
(E) 2x8 JOISTS
PROVIDE PTD 1x4 TRIM
SURROUND @ HATCH OPENING
ACCESS LADDER FRAME PER MFR
RO
FLOOR TO CEILING HT
APPROX 8'-0"
DETAILS BASED UPON
WERNER #WH2208 "WOOD
FOLDING HEAVY DUTY
ACCESS LADDER"
350# LOAD CAPACITY
REQUIRED CLR LANDING SPACE
TOTAL LADDER PROJECTION
REFER TO SHEET ___ FOR
LOCATION
2'-2 1/2"
ADD NEW FURRING
AS REQUIRED
REMOVE PORTION OF (E)JOIST
NEW HEADER BEYOND
STRINGER
BRACE
STRINGER
BRACE
ACCESS LADDER FRAME &
DOOR PANEL PER MFR
RO
1 1st FLOOR PLAN
SCALE: 1 1/2"= 1'-0"2 LONGITUDINAL HATCH SECTION
SCALE: 1 1/2"= 1'-0"3 WIDTHWISE HATCH SECTION
N
DLL
MKD
08/24/11
A-3DLL
1ST FLOOR PLAN
012 12
SCALE OF INCHES
SCALE E
SCALE C
04 4 8
SCALE OF FEET
CSCALE
GENERAL NOTES:
1. COVER AND PROTECT AREAS ADJACENT
TO AREA OF WORK.
2. REMOVE, WRAP, PROTECT AND STORE (AT
THE NPS DIRECTION) PENDANT FIXTURES
AT GIFT SHOP.
STEEL VISITOR CENTER
171188
DATE:
DESIGNED: SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
TITLE OF SHEET
TECH. REVIEW:
109418
2 3 4 5
B
C
D
E
G
F
A
E
D
C
B
G
A
F
2 3 4 5 61
HH
B.1B.1
B.2B.2
D.1D.1
D.2D.2
A-4
A-4
A-4
A-4
A-4
103'-1" +-
'-4
A-6
A-6
A-6
A-6
A-6
A-6
A-6
A-6
(N) ATTIC ACCESS HATCH ABOVE.
1 2 3 4 5 6
1110987
(E) LOAD BEARING
PONY WALL ALIGNMENT
(E) LOAD BEARING PONY
WALL ALIGNMENT
PARK
LIBRARY
STOR.LAV.
JANITOR
CORRIDOR
ASSOC.
OFFICE
WORKSHOP/
OFFICE
INTERP.
WORKSHOP
MUSEUM
COLLECTION
STORAGE
1 2nd FLOOR PLAN
NOT TO SCALE2 DORMER 6 DTL.
NOT TO SCALE3 DORMER 5 DTL.
(E) CONDITION REPAIR TO MATCH
ORIGINAL FINISHES @ DORMERS
(E) CONDITION REPAIR TO MATCH
ORIGINAL FINISHES @ DORMERS
N
DLL
MKD
08/24/11
A-4DLL
2ND FLOOR PLAN
SCALE C
04 4 8
SCALE OF FEET
CSCALE
GENERAL NOTES:
1. COVER AND PROTECT AREAS ADJACENT TO AREA OF WORK.
2. AT ALL DORMERS WHERE WATER DAMAGE IS PRESENT PATCH AND REPAIR
(E) 1/2" TYPE 'X' GWB AS REQUIRED. (TYPICAL EXISTING CONDITIONS
SHOWN IN DETAILS 2-6 BELOW). NOTIFY OWNER & ARCHITECT IF
EVIDENCE OF DRY ROT IS FOUND IN EXPOSED FRAMING MEMBERS.
STEEL VISITOR CENTER
171188
DATE:
DESIGNED: SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
TITLE OF SHEET
TECH. REVIEW:
109418
2 3 4 5
B
C
D
E
G
F
A
E
D
C
B
G
A
F
2 3 4 5 61
HH
B.1B.1
B.2B.2
D.1D.1
D.2D.2 1 A-6
A-6
A-6
A-6
A-6
A-6
A-6
A-6
(E) VALLEY FLASHING TO
REMAIN - PATCH ANY
OPENINGS WITH ASPHALTIC
ROOFING CEMENT AT ALL (3)
GABLE DORMERS PER 5/A6.
APPROX. 6:12
(E) ROOF SLOPE
APPROX. 6.5:12
(E) ROOF SLOPE
APPROX. 14:12
(E) ROOF SLOPE
APPROX. 14:12
(E) ROOF SLOPE
APPROX. 14:12
(E) ROOF SLOPE
APPROX. 6:12
(E) ROOF SLOPE
APPROX. 14:12
(E) ROOF SLOPE
AREA OF WORK AREA OF WORK AREA OF WORK AREA OF WORK AREA OF WORK AREA OF WORK
AREA OF WORKAREA OF WORK
AREA OF WORK
AREA OF WORK
(E) LOAD BEARING
PONY WALL ALIGNMENT
(E) LOAD BEARING PONY
WALL ALIGNMENT
A-6
A-6
A-6
PROTECT (E) CHIMNEY
STONEWORK
NEW COPPER CAP W/
HEMMED 1" DRIP EDGE
(E) FLUE TERMINATION
CAPS, NOT IN USE
REMOVE (E) CHIMNEY CAP,
PROTECT STONE FOR
STORAGE FOR LATER
REINSTALLATION. PROTECT
(E) CHIMNEY STONEWORK
WHICH IS TO REMAIN
VIF, TO COVER (E) FLUE
TERMINATION CAPS
PROVIDE BLOCKING
SUPPORT @ 12" O.C.
FOR METAL CAP
LINE OF MASONRY
REMOVAL
NOT TO SCALE5 W. CHMNY CRICKET DTL.
1 ROOF PLAN
2 EAST CHIMNEY SECTION DTL.
NOT TO SCALE3 S. GABLE DORMER DTL.
NOT TO SCALE4 W. CHMNY CRICKET DTL.
CONTRACTOR TO PROVIDE FOR ASPHALTIC
WATERPROOFING PATCHING @ ALL EXPOSED
FLASHING
CONTRACTOR TO PROVIDE FOR ASPHALTIC
WATERPROOFING PATCHING @ ALL EXPOSED
FLASHING
CONTRACTOR TO PROVIDE FOR ASPHALTIC
WATERPROOFING PATCHING @ ALL EXPOSED
FLASHING
N
DLL
MKD
08/24/11
A-5DLL
ROOF PLAN
CSCALE
SCALE C
04 4 8
SCALE OF FEET
SCALE D
01 1 2
SCALE OF FEET
DSCALE
GENERAL NOTES:
1. COVER AND PROTECT AREAS ADJACENT TO AREA OF WORK.
2. CONTRACTOR TO PROVIDE FOR ASPHALTIC WATERPROOFING @ ALL
EXPOSED FLASHING (TYP. CONDITIONS SHOWN IN DTLS 3/A-5 - 5/A-5.)
STEEL VISITOR CENTER
171188
DATE:
DESIGNED: SUB SHEET NO.
PMIS/PKG NO.
DRAWING NO.
SHEET
OF
TITLE OF SHEET
TECH. REVIEW:
109418
A-6
A-6
REMOVE & PROTECT (E)
WINDOW & CASING, FOR
REINSTALLATION. TYP @
ALL SHED & GABLE
DORMERS. INSTALL (N) 1X
TRIM TO MATCH (E) AT
DORMERS 5 & 6.
EXIST. PLYWD
SHEATHING, TYP
(E) SHAKES, TYP
(E) INSULATION
COVER ALL DORMER WALLS WITH (N)
ICE & WATER SHIELD PER DTL. 6/A-6
SIM
GEN. NOTE: AT ALL DORMERS
WHERE WATER DAMAGE IS
PRESENT PATCH AND REPAIR
(E) 1/2" TYPE 'X' GWB AS
REQUIRED. NOTIFY ARCHITECT
IF EVIDENCE OF DRY ROT IS
FOUND IN EXPOSED FRAMING
MEMBERS.
A-6
A-4
A-6
A-6
A-6
(E)
INSULATION
INSTALL (N) BASE
@ DORMERS 5 & 6
PATCH & PAINT TO
MATCH EXISTING
BASE.
AT DORMERS 5 & 6
INSTALL (N) 1/2"
TYPE 'X' GWB.
PAINT TO MATCH
(E) INT. FINISHES
SEE 1/A-4 FOR TYP
NOTES
GEN. NOTE: AT ALL DORMERS
WHERE WATER DAMAGE IS
PRESENT PATCH AND REPAIR
(E) 1/2" TYPE 'X' GWB AS
REQUIRED. NOTIFY ARCHITECT
IF EVIDENCE OF DRY ROT IS
FOUND IN EXPOSED FRAMING
MEMBERS.
A-6
A-6
REMOVE & REPLACE 2 COURSES OF SHINGLES
9"
8"
8"
REMOVE, PROTECT &
STORE WINDOW DURING
CONSTRUCTION.
REINSTALL WINDOW &
CAULK SURROUND.
WET FLASH ROUGH
OPENING
(E) PLYWD
(E) I&W SHIELD
(N) I&W SHIELD
REPLACE (E)
SHINGLES AFTER
INSTALLATION OF
(N) FLASHING
COPPER FLASHING
COPPER
COUNTERFLASHING
(N) GWB AT DORMERS
5 & 6 AND OTHERS AS
REQUIRED. PATCH TO
MATCH (E) CONDITION
WET-FLASH, TYP
16 GA. COPPER HEADER
FLASHING W/ DRIP
(N) I&W SHIELD OVER
HEADER FLASHING
WET-FLASH
JOINT SEALANT
I&W SHIELD TO LAP
3RD COURSE OF
SHAKES BY 4"
PROVIDE
CONTINUOUS
CAULKING @ (N)
COUNTERFLASHING
TY
P
H
E A
D
J A
M B
SILL
HEADER
(JAMB SIM)
APPLY (N) 30# ROOFING
FELT @ REINSTALLATION
OF (N) SHAKES
STAGGERED EXPOSURE TO MATCH EXISTING PATTERN
6"
REMOVE SHINGLES AS
6"
I & W SHIELD TO LAP 12" OVER FIELD
(N) ICYNENE INSULATION @
EXPOSED DORMER WALLS, TYP
NEW STEPPED FLASHING @ DORMERS; WRAP 12" UP
DORMER WALL & EXTEND 6" BEYOND DORMER UNDER
ROOFING. REMOVE & REPLACE SHINGLES AS REQUIRED.
TYP @ ALL SHED & GABLE DORMERS.
(E) FELT @ ROOF TO BE DRAWN BACK
AFTER REMOVAL OF SHAKES & TO BE
RELAID OVER (N) ICE & WATER SHIELD AND
WOVEN INTO STEP SHINGLES
(N) I&W SHIELD @ DORMER WALLS, LAP
OVER (E) @ ROOF, EXTEND PAST
REMOVED SHINGLE ROOFING; EXTEND TO
UNDERSIDE OF EAVE @ WALL, TYP
MIN 6" EXPOSURE OF FLASHING
LAP 2ND LAYER OF MEMBRANE OVER
FLASHING 4" LAP MINIMUM. I&W SHIELD
SHOULD NOT BE EXPOSED @ STEP FLASHING.
(E) ICE & WATER
SHIELD AT ROOF
REQUIRED FOR ACCESS
(±18")
APPLY ASPHALTIC
MASTIC @ ALL VALLEY
LOCATIONS WHERE
METAL LAPS METAL
FIT LEAD SHEET FLASHING
UNDER SECOND SHAKE COURSE,
FORMING OVER VALLEY & RIDGE.
REMOVE FIRST COURSE OF (E)
SHAKESTO APPLY (N) LEAD SHEET
FLASHING AND (N) ICE & WATER
SHIELD @ LEAD AND COPPER
FLASHING.
REMOVE CEDAR RIDGE CAP &
FIRST COURSE OF (E) SHAKES TO
APPLY (N) LEAD SHEET FLASHING
AND (N) ICE & WATER SHIELD @
LEAD AND COPPER FLASHING.
2"
8"
A-6
(E) SHAKES
(E) 3/4" SHEATHING
(N) COPPER FLASHING
W/ HEMMED EDGE @
(E) 4x8 OUTRIGGER(S)
TO EXTEND UP WALL 8"
UNDER SIDING.
(N) ICE & WATER SHIELD
(E) PTD FASCIA
INSTALL (N) CEDAR SHAKE SIDING
OVER (N) ICE & WATER SHIELD
PROVIDE (3) BORATE
RODS PER OUTRIGGER
UNDER FLASHING CAP
SCALE: 1/2" = 1'-0"1 GABLED DORMER
SCALE: 1/2" = 1'-0"2 GABLE DORMER (KEY)
SCALE: 1/2" = 1'-0"3 SHED DORMER
SCALE: 1/2" = 1'-0"4 SHED DORMER (KEY)
SCALE: 3" = 1'-0"8 WINDOW DETAIL
SCALE: 3" = 1'-0"6 DORMER WALL
NOT TO SCALE5 DTL. AT DORMER GABLE AND VALLEY (TYP.)
SCALE: 1 1/2"= 1'-0"7 GABLE OUTRIGGER DETAIL
DLL
MKD
08/24/11
A-6DLL
WINDOW AND FLASHING
DETAILS
File details come from the government source that posted it. Updated .