This document package includes plans and drawings for a temporary visitor center project at Crater Lake National Park. The project involves constructing modular buildings and associated site work to replace an existing steel visitor center. Drawings show the floor plans, elevations, sections and details of the proposed modular buildings, restroom building, and snow roof structure. Utilities, framing, foundation and other construction aspects are depicted. Specifications and notes provide additional information.
View the file
Other files for this federal contract opportunity
Show all 35
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
VERTICAL DATUM
HORIZONTAL DATUM
EXISTING 12'
ELECTRICAL POLE
EXISTING WATER LINE NETWORK
CONTRACTOR TO VERIFY
THE INTEGRITY OF THE P.O.C.
EXISTING PARKING LOT LANDSCAPE
ISLAND TO BE PROTECTED.
(TYPICAL FENCING SYMBOL)
ANNIE CREEK
RESTAURANT
CAMPER
STOREM
U N
SO
N
VALLEY R
O
AD
CRATER LAKE HW
Y
EXISTING 6" CLAY LINE
AC
CE
SS
R
OAD
PACIFIC POWER & LIGHT
PRIMARY 5" CONDUIT
EXISTING ELECTRICAL
POWER HOOKUP - MAY
CONNECT TO THE WEST
EXISTING
UNPAVED
TRAIL
SS2
SS2
EXISTING
TRANSFORMER
EXISTING PAD MOUNTED
UTILITY TRANSFORMER
SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
1/2 9/2
0 1
:55 :15
P M
\\a nc
-fs \A
NC
-P ro jec ts\
\62
1-
\65
CA
D\ La nd sc ap e\_
CD
\P
LA
NS
\T
VC
\C
-E
CO
N.
dw g
P Gaynor
B Doggett
P Gaynor
CRATER LAKE NATIONAL PARK
2020.11.20
198641 of 152
142813
TVC
C1.0GI
D
UOYEROFEB
LLAC
OREGON UTILITY
NOTIFICATION CENTER
1-800-332-2344
TEMP VISITOR CENTER
EXISTING CONDITIONS
PLAN
UNDERGROUND UTILITY LOCATIONS SHOWN
ARE BASED UPON VARIOUS RECORD UTILITY
MAPS IN CONJUNCTION WITH VISIBLE
EVIDENCE GATHERED DURING THE TIME THE
FIELD SURVEY WAS PERFORMED.
THEREFORE, ALL UNDERGROUND UTILITY
LOCATIONS SHOULD BE FIELD VERIFIED
PRIOR TO CONSTRUCTION.
VERTICAL DATUM: ELEVATIONS ARE NAVD88
EXPRESSED IN INTERNATIONAL FEET.
HORIZONTAL DATUM: NAD83(2011) LOCAL DATUM PLANE
BASED ON OREGON STATE PLANE SOUTH COORDINATES
EXPRESSED IN INTERNATIONAL FEET.
2 22
PLAN LEGEND:
PROJECT BOUNDARY (+/- 7,248 SF)
EXISTING ELECTRICAL SERVICE LINE
EXISTING WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING 6" STORM DRAIN PIPE
EXISTING ELECTRICAL VAULTS
EXISTING COMMUNICATIONS J-BOX
EXISTING 2" WATER VALVE
EXISTING SANITARY SEWER MANHOLE
EXISTING STORM CATCH BASIN
EXISTING CONIFER TREE TO REMAIN
(CANOPY DRIP-LINES ARE BASED ON AERIAL
IMAGERY)
E E
W W
SS
SD
SITE INFORMATION
LOCATED WITHIN THE BOUNDARY OF CRATER LAKE NATIONAL PARK, KLAMATH COUNTY, CRATER LAKE, OREGON.
DATUM
HORIZONTAL CONTROL:
NAD83(2011) LOCAL DATUM PLANE BASED ON OREGON STATE PLANE SOUTH COORDINATES EXPRESSED IN
INTERNATIONAL FEET.
VERTICAL CONTROL:
ELEVATIONS ARE NAVD88(GEOID18) EXPRESSED IN INTERNATIONAL FEET.
E
E
E
E E
SV
SV
SS2
SS2
SS2
SS2
ABA
ABA
DN
AUDITORIUM
LOBBY/ SALES
MAIL ROOM
STORAGE
MEN'S RESTROOM
WOMEN'S
RESTROOM
RAMP
PLATFORM
ANTICIPATED LIMITS OF GROUND
DISTURBANCE (+/- 1,969 SF)
SNOW CANOPY OVERHANG
EXISTING WATER LINE NETWORK
CONTRACTOR TO VERIFY
THE INTEGRITY OF THE P.O.C.
ANTICIPATED LIMITS OF UTILITY TRENCHING
FOR SANITARY CONNECTION. (+/- 797 SF)
ANTICIPATED AREA OF EXISTING
PARKING LOT FOR (18) VISITOR
AND (2) SERVICE VEHICLES.
CONTRACTOR TEMPORARY STAGING AREA
· TWO STALLS FOR EMPLOYEE PARKING
· CONTRACTOR TRAILER PARKING
· LAY DOWN SPACE
EXISTING PARKING LOT LANDSCAPE
ISLAND TO BE PROTECTED. NOT
PART OF PROJECT.
TEMPORARY VISITOR CENTER
& RESTROOMS
WATER LINE TAP
FOR RESTROOM AND
THE TEMPORARY
VISITOR CENTER
PACIFIC POWER & LIGHT
PRIMARY 5" CONDUIT
EXISTING UNPAVED TRAIL
AREA FOR
SNOW
STORAGE
SS2
ANNIE CREEK
RESTAURANT
CAMPER
STORE
CRATER LAKE HW
Y
AC
CE
SS
R
OAD
ANTICIPATED ONE-WAY
CIRCULATION ROUTE
TEMPORARY RE-STRIPING FOR (ADA)
AND (SV) PARKING STALLS
TEMPORARY STAGING AND MANEUVERING AREA
FOR TEMPORARY VISITOR CENTER SET-UP
ANTICIPATED LIMITS OF SNOW
REMOVAL REQUIRED FOR VISITOR AND
SERVICE VEHICLE ACCESS AND
MOVEMENT.
TEMPORARILY PAINT 'RESERVED -
STAFF ONLY' ON TWO STALLS FOR
STAFF VEHICLES
CONNECT TO EXISTING
TRANSFORMER FOR ELEC.
MEN'S RESTROOM
WOMEN'S
RESTROOM
RAMP
SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
1/2 9/2
0 1
:55 :15
P M
\\a nc
-fs \A
NC
-P ro jec ts\
\62
1-
\65
CA
D\ La nd sc ap e\_
CD
\P
LA
NS
\T
VC
\C
-P
RO
G.
dw g
P Gaynor
B Doggett
P Gaynor
CRATER LAKE NATIONAL PARK
2020.11.20
198641 of 152
142813
TVC
C2.0GI
D
UOYEROFEB
LLAC
OREGON UTILITY
NOTIFICATION CENTER
1-800-332-2344
TEMP VISITOR CENTER
PROGRAM AND PROJECT
LIMITS PLAN
VERTICAL DATUM: ELEVATIONS ARE NAVD88
EXPRESSED IN INTERNATIONAL FEET.
HORIZONTAL DATUM: NAD83(2011) LOCAL DATUM PLANE
BASED ON OREGON STATE PLANE SOUTH COORDINATES
EXPRESSED IN INTERNATIONAL FEET.
CRATER LAKE HW
Y
SIGNS FOR "PARK
VISITOR CONTACT
STATION" ROAD
GUIDE SIGN AND
RG-5 SIGN
SIGN FOR "PARK VISITOR
CONTACT STATION" ROAD
GUIDE SIGN AND RG-5
SIGN
M U
N
SO
N
VA
LLEY R
O
A D
ENTRANCE SIGN LOCATION MAP
PLAN LEGEND:
PROJECT BOUNDARY (+/- 7,248 SF)
LIMIT OF DISTURBANCE (+/- 2,571)
EXISTING ELECTRICAL SERVICE LINE
EXISTING WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING 6" STORM DRAIN PIPE
EXISTING ELECTRICAL VAULTS
EXISTING COMMUNICATIONS J-BOX
EXISTING 2" WATER VALVE
EXISTING SANITARY SEWER MANHOLE
EXISTING STORM CATCH BASIN
EXISTING CONIFER TREE TO REMAIN (CANOPY
DRIP-LINES ARE BASED ON AERIAL IMAGERY)
E E
W W
SS
SD
PROPOSED OVERHEAD ELECTRICAL (+/- 260 LF)
PROPOSED SANITARY SEWER (+/- 90 LF)
TEMPORARY SITE SECURITY FENCING
E E
SIGN NOTES:
REFER TO 'NPS UNIGUIDE STANDARDS:
VOLUME 2 ROADWAY SIGNS' FOR ROADWAY
SIGN DESIGN. MOUNT SIGNS BELOW
EXISTING SIGNS ON EXISTING POST. WINTER
SIGNS REQUIRE SEPARATE SIGN EXTENSION
POST TO ENSURE VISIBILITY ABOVE SNOW
PACK. POST TO BE OF SUITABLE MATERIAL
TO WITHSTAND THE REGIONAL SNOW LOAD
ANNIE SPRING
ENTRANCE STATION
UNDERGROUND UTILITY LOCATIONS SHOWN
ARE BASED UPON VARIOUS RECORD UTILITY
MAPS IN CONJUNCTION WITH VISIBLE
EVIDENCE GATHERED DURING THE TIME THE
FIELD SURVEY WAS PERFORMED.
THEREFORE, ALL UNDERGROUND UTILITY
LOCATIONS SHOULD BE FIELD VERIFIED
PRIOR TO CONSTRUCTION.
4" WIDE WHITE
STRIPES @ 2' O.C. AT
36 DEGREES
TYPICAL A.B.A.
PARKING SYMBOL. SEE
DETAIL ON THIS SHEET.24'-10"
9.0'
NOTE: CONSTRUCT / INSTALL FACILITIES
IN ACCORDANCE WITH OSSC CHAPTER 11
9.0'
PER PLAN 8' MIN FOR
WHEELCHAIR OR VAN ACCESSIBLE
A.B.A. PARKING STALL
NOT TO SCALE
28" MINIMUM
BACKGROUND
24" MINIMUM
3" MINIMUM
1.
2.
3.
PAVEMENT MARKING
BACKGROUND: OPTIONAL:
BLUE, RETRO-REFLECTIVE
PAVEMENT MARKING STENCIL:
WHITE, RETRO-REFLECTIVE
THE PAVEMENT MARKING
STENCIL SHALL BE USED TO
DESIGNATE AN ACCESSIBLE
PARKING AREA RESERVED FOR
VEHICLES WITH DMV PERMITS.
NOTES
TYPICAL A.B.A. PARKING SYMBOL
NOT TO SCALE
SNOW CLEARANCE AREA BY NPS STAFF
SNOW STORAGE BY NPS STAFF
TEMPORARY STAGING AREA
PARKING AREA
(STROKE WIDTH)
GENERAL NOTES
CONTRACTOR WILL REFER TO SPEC SECTION 01 40 00 FOR
'ACCESSIBILITY INSPECTION REPORT' REQUIREMENTS, TO
DOCUMENT COMPLIANCE WITH ABAAS AT VARIOUS STAGES OF
CONSTRUCTION.
AC
CE
SS
R
OAD
E
E
E E
DN
AUDITORIUM
LOBBY/ SALES
MAIL ROOM
STORAGE
MEN'S RESTROOM
WOMEN'S
RESTROOM
RAMP
PLATFORM
SS
SS
SS
SNOW CANOPY
OVERHANG
ANTICIPATED AREA OF
EXISTING PARKING LOT FOR
(18) VISITOR AND (2) SERVICE
VEHICLES.
EXISTING PARKING LOT
LANDSCAPE ISLAND TO
BE PROTECTED. NOT
PART OF PROJECT.
TEMPORARY
VISITOR CENTER
& RESTROOMS
TEMPORARY
RE-STRIPING FOR
(ABA) AND (SV)
PARKING STALLS
ANNIE CREEK
RESTAURANT
CAMPER
STOREM
U N
SO
N
VALLEY R
O
AD
CRATER LAKE HW
Y
AC
CE
SS
R
OAD
SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
1/2 9/2
0 1
:55 :15
P M
\\a nc
-fs \A
NC
-P ro jec ts\
\62
1-
\65
CA
D\ La nd sc ap e\_
CD
\P
LA
NS
\T
VC
\C
-L
SP
R.
dw g
P Gaynor
B Doggett
P Gaynor
CRATER LAKE NATIONAL PARK
2020.11.20
198641 of 152
142813
TVC
C3.0GI
D
UOYEROFEB
LLAC
OREGON UTILITY
NOTIFICATION CENTER
1-800-332-2344
TEMP VISITOR CENTER
LANDSCAPE PROTECTION
PLAN
UNDERGROUND UTILITY LOCATIONS SHOWN ARE
BASED UPON VARIOUS RECORD UTILITY MAPS IN
CONJUNCTION WITH VISIBLE EVIDENCE GATHERED
DURING THE TIME THE FIELD SURVEY WAS
PERFORMED. THEREFORE, ALL UNDERGROUND
UTILITY LOCATIONS SHOULD BE FIELD VERIFIED
PRIOR TO CONSTRUCTION.
VERTICAL DATUM: ELEVATIONS ARE NAVD88
EXPRESSED IN INTERNATIONAL FEET.
HORIZONTAL DATUM: NAD83(2011) LOCAL DATUM PLANE
BASED ON OREGON STATE PLANE SOUTH COORDINATES
EXPRESSED IN INTERNATIONAL FEET.
FINISH GRADE
PLAN LEGEND
E E
TREE PROTECTION NOTES
INSTALL TREE PROTECTION FENCING AS INDICATED ON PLAN
AND DETAIL 1 ON THIS SHEET.
GALVANIZED CHAIN-LINK
FENCING AND POLES TO BE
SET AROUND TREE OR
GROUPS OF TREES.
TREE DRIPLINE
DIAMETER VARIES
6'-0" MIN
EXISTING CONIFER TREE TO
REMAIN. REFER TO PLAN
SHEET FOR LOCATIONS.
DETAIL: TREE PROTECTION FENCING
SCALE: N.T.S.1
PROJECT BOUNDARY (+/- 7,248 SF)
TEMPORARY STAGING AREA
EXISTING ELECTRICAL VAULTS
EXISTING COMMUNICATIONS J-BOX
EXISTING WATER VALVE
EXISTING SANITARY SEWER MANHOLE
EXISTING STORM CATCH BASIN - REPLACE IF
DAMAGED
EXISTING CONIFER TREE TO REMAIN
(CANOPY DRIP-LINES ARE BASED ON AERIAL
IMAGERY)
TREE PROTECTION FENCE
GENERAL NOTES
CONTRACTING OFFICER HAS THE AUTHORITY TO APPROVE
ADDITIONAL FENCING PROPOSED BY THE CONTRACTOR.
PROPOSED OVERHEAD ELECTRICAL (+/- 260 LF)
PROPOSED SANITARY SEWER (+/- 90 LF)
PROPSOED RE-VEGETATION SEED MIX
SS
4 22
E
E
E E
DN
AUDITORIUM
LOBBY/ SALES
MAIL ROOM
STORAGE
MEN'S RESTROOM
WOMEN'S
RESTROOM
RAMP
PLATFORM
SS
0+00
0+90 SNOW CANOPY
OVERHANG
EXISTING WATER LINE NETWORK
CONTRACTOR TO VERIFY
THE INTEGRITY OF THE P.O.C.
ANTICIPATED LIMITS OF
UTILITY TRENCHING
FOR SANITARY
CONNECTION.
(+/- 603 SF)
EXISTING 6" CLAY LINE
TEMPORARY
VISITOR CENTER
& RESTROOMS
WATER LINE TAP FOR
RESTROOM AND THE
TEMPORARY VISITOR
CENTER
TEMPORARY
RE-STRIPING FOR
(ADA) AND (SV)
PARKING STALLS
PACIFIC POWER & LIGHT
PRIMARY 5" CONDUIT
SS2
SS2
SS2
SS2
EXISTING
TRANSFORMER
ANNIE CREEK
RESTAURANT
CAMPER
STORE
CRATER LAKE HW
Y
AC
CE
SS
R
OAD
SV
SV
EXISTING PAD MOUNTED
UTILITY TRANSFORMER.
COORDINATE WITH UTILITY
FOR NEW POWER SERVICE.
NEW BURIED POWER SERVICE TO THE
BUILDING. SHARE COMMON TRENCH
WITH WATER SERVICE. CONDUIT BY
CONTRACTOR, CABLING BY UTILITY.
NEW METER/MAIN ON BUILDING
EXTERIOR OR PEDESTAL
MOUNTED. COORDINATE EXACT
LOCATION.
-1.83% -1.52% -0.75% -0.78%2.15% 1.27% 1.63%
2.65%
1.71%
1.73%
GRADE BREAK STA = 0+18.27
ELEV = 6022.631 GRADE BREAK STA = 0+89.85
ELEV = 6022.588
SHEET
PMIS/PKG NO.
DRAWING NO.SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
1/2 9/2
0 1
:55 :15
P M
\\a nc
-fs \A
NC
-P ro jec ts\
\62
1-
\65
CA
D\ La nd sc ap e\_
CD
\P
LA
NS
\T
VC
\C
-U
TI
L.d wg
P Gaynor
B Doggett
P Gaynor
CRATER LAKE NATIONAL PARK
2020.11.20
198641 of 152
142813
TVC
C4.0GID
UOYEROFEB
LLAC
OREGON UTILITY
NOTIFICATION CENTER
1-800-332-2344
TEMP VISITOR CENTER
UTILITY PLAN
UNDERGROUND UTILITY LOCATIONS SHOWN ARE
BASED UPON VARIOUS RECORD UTILITY MAPS IN
CONJUNCTION WITH VISIBLE EVIDENCE GATHERED
DURING THE TIME THE FIELD SURVEY WAS
PERFORMED. THEREFORE, ALL UNDERGROUND
UTILITY LOCATIONS SHOULD BE FIELD VERIFIED
PRIOR TO CONSTRUCTION.
VERTICAL DATUM: ELEVATIONS ARE NAVD88
EXPRESSED IN INTERNATIONAL FEET.
HORIZONTAL DATUM: NAD83(2011) LOCAL DATUM PLANE
BASED ON OREGON STATE PLANE SOUTH COORDINATES
EXPRESSED IN INTERNATIONAL FEET.
PLAN LEGEND
PROJECT BOUNDARY (+/- 7,010 SF)
LIMIT OF DISTURBANCE (+/- 2,571)
STAGING AREA
EXISTING ELECTRICAL SERVICE LINE
EXISTING 2" WATER LINE
EXISTING SANITARY SEWER LINE
EXISTING 6" STORM LINE
EXISTING ELECTRICAL VAULTS
EXISTING COMMUNICATIONS J-BOX
EXISTING WATER VALVE
EXISTING SANITARY SEWER MANHOLE
EXISTING STORM CATCH BASIN
EXISTING CONIFER TREE TO REMAIN
(CANOPY DRIP-LINES ARE BASED ON AERIAL
IMAGERY)
PROPOSED 4" WATER VALVE
E E
W W
SS
SD
E E PROPOSED OVERHEAD ELECTRICAL (+/- 260 LF)
PROPOSED SANITARY SEWER (+/- 90 LF)SS
UTILITY TRENCH SECTION - BACKFILL
NOT TO SCALE
PIPE ZONE
BEDDING
PIPE ZONE
BACKFILL
BACKFILL ABOVE
PIPE ZONE
18"MIN.
4"MIN.
PIPE O.D.
PLUS 18"MIN.
3/4"-0" CRUSHED ROCK
SEWER MAIN
3/4"-0" CRUSHED ROCK
EXISTING MATERIAL
3/4"-0" CRUSHED ROCK IN
PAVED AREA
GRANULAR BACKFILL OR
APPROVED NATIVE
MATERIAL IN AREAS
OUTSIDE OF PAVEMENT.
EXISTING SURFACE
GRADE
PROPOSED SANITARY SEWER PROFILE
CAST IRON FRAME
11 1/2"
10 1/2" 3/4"
1 1/8"
1/2" 6 3/
8"
4"
4"
9"
10 3/8"
MIN
MIN
4"
4"
4"
6"
MIN
MIN
NOTE:
3/4"-0 COMPACTED
AGGREGATE BASE ROCK
CLEANOUT
STANDARD CLEANOUT DETAIL
NOT TO SCALE
CAP
4" CONCRETE
ALL CLEANOUT MATERIAL TO
BE SAME AS CARRIER PIPE.
NOTE:
INSTALL 2'x2'x4" CONCRETE
PAD IN UNPAVED AREA.
CONCRETE PAD REQUIRED
IN PAVED AREAS ONLY
AS
SPECIFIED
17 1/8"
CLASS 3000
CONCRETE
MECHANICAL PLUG
3/4"
2 3/8" 1/2"
9 7/8"
5/8"
CAST IRON COVER
AC OR CONCRETE PAVING
OR OTHER SURFACING
Don Wilcox
1" PE SERVICE LINE (ALL SERVICES
LINES SHALL BE IRON PIPE SIZE [IPS])
PROPERTY PIN
P/L
P/L
KEY VALVE ASSEMBLY
CUSTOMER SERVICE VALVES
WATER METERS BY CITY AT TIME OF SERVICE APPLICATION.
PLAN
METER
6" MIN.
DRAIN
ROCK
3/4" COPPER TAIL PIECE WITH 3/4" BRASS
FEMALE ADAPTER AND PLUG BY CONTRACTOR
2"±
P/L
1" PE SERVICE LINE (ALL SERVICES
LINES SHALL BE IRON PIPE SIZE [IPS])
PROFILE
EXTENSION RISER REQ.'D
14 AWG
TRACER
WIRE
30" MIN.
COVER
INSTALL METER BOX
FLUSH WITH SIDEWALK
SERVICE
SADDLE
CORP. STOP
FINISHED GRADE
24"
MIN.
24"±
18"
45.0°
KEY VALVE BRANCH ASSEMBLY BY FORD, MODEL UV63-42W,
OR COMPATIBLE EQUAL, CONTRACTOR TO VERIFY EXACT
MODEL NO. W/ CITY PRIOR TO ORDERING. (REFER TO
CONSTRUCTION NOTE 3)
CUSTOMER SERVICE VALVES WITH INLET SIDE METER COUPLER BY
CONTRACTOR.
1" IPT IDLER (MXM) 7 1/2" LONG (A.Y. McDONALD PART #40MJ07, FORD PART #IDLER-2, MUELLER PART #H-10887 5/8x3/4 OR EQUAL)
CONSTRUCTION NOTES
AT FUTURE METER LOCATIONS BY CONTRACTOR. 1 1/2" OR 2"
CITY OF KLAMATH FALLS
RESIDENTIAL 1/2002
GDGWATER SERVICE CONNECTION
1 6/04 2nd EDITION
SPLICE
TRACER WIRE
W/ MAIN LINE
WIRE
METER SPACER PER MANUFACTURER REQUIREMENTS.
2 6/06 4th EDITION
3 3/10 5th EDITION
MAIN LINE
45°
45°
FLOW
A
A
45° WYE
45° ELBOW
R.O.W. LINE
SEE NOTE 1
PLAN VIEW
NTS
MAIN LINE
SERVICE LATERAL @ 2% SLOPE
45° ELBOW
45° WYE
SECTION A-A
NTS
R.O .W
. L
INE
45° ELBOW
45° WYE
CITY MAINTENANCE
CASTING
Min.
4 1/8"
8" Min.
6" Min.
POURED IN PLACE
COMPACTED FILL
CONC. COLLAR ON
24" Min.
12" Min.
24"
12"
12" 24"
OR AS DIRECTED BY CITY
LOCATOR WIRE
14 AWG SINGLE STRAND
CITY OF KLAMATH FALLS
LATERAL CONNECTION 1/2002
GDGSTANDARD WYE SERVICE
Don Wilcox1 6/04 2nd EDITION
NO HORIZONTAL
BENDS
WIRE (SPLICE TRACER
MAIN LINE LOCATOR
WIRE W/MAIN LINE WIRE)
2 3/10 5th EDITION
1. CONTRACTOR TO INSTALL 20' LENGTH OF PIPE WITH PLUG @ 2% SLOPE.
CONSTRUCTION NOTES:
NOTE:
1. BACKFILL IN 6" LIFTS.
2. THE BACKFILL IN
PAVEMENT AND BUILDING
AREAS SHOULD BE AT
LEAST 92% OF THE
MAXIMUM DRY DENSITY AS
DETERMINED BY THE
MODIFIED PROCTOR TEST
METHOD (ASTM D 1557)
BELOW 1 FT FROM THE
FINISHED SUBGRADE
SURFACE AND 95% IN THE
UPPER 1FT.
3. ON-SITE SPOILS MAY BE
USED FOR BACKFILL IN
LANDSCAPE AREAS
OUTSIDE THE PIPE
BEDDING ZONE.
4. USE OF NATIVE MATERIAL
FOR BACKFILL TO BE
DETERMINED BY
CONTRACTING OFFICER.
PICK HOLE
1. ALL POLYETHYLENE (PE) PIPE SHALL CONTAIN STAINLESS STEEL INSERT STIFFENERS INSIDE
BOTH ENDS OF PIPE.
2. METER BOXES SHALL BE SET IN THE SIDEWALK AT THE BACK OF SIDEWALK OR DIRECTLY BEHIND
THE BACK OF SIDEWALK.
3. REFER TO STANDARD DRAWINGS 7-100a - 7-100c FOR PARTS LIST.
4. 4. TRACER WIRE SHALL BE EXTENDED 24" ABOVE FINISHED SURFACE AND LEFT COILED UNDER
METER BOX LID.
THE CITY OF KLAMATH FALLS IS NOT THE GOVERNING JURISDICTION. THESE DETAILS
ARE FOR REFERENCE.
THE CITY OF KLAMATH FALLS IS NOT THE GOVERNING JURISDICTION. THESE DETAILS
ARE FOR REFERENCE.
GENERAL
DRAWINGS INDICATE GENERAL AND TYPICAL DETAILS OF CONSTRUCTION. TYPICAL DETAILS AND NOTES SHOWN ON THESE DRAWINGS ARE PART OF THE CONSTRUCTION CONTRACT AND SHALL BE PROVIDED BY THE CONTRACTOR. TYPICAL DETAILS MAY NOT NECESSARILY BE INDICATED ON THE PLANS BUT SHALL APPLY AS SHOWN OR DESCRIBED IN THE DETAILS AND NOTES. WHERE CONDITIONS ARE NOT SPECIFICALLY INDICATED BUT ARE OF SIMILAR CHARACTER TO DETAILS SHOWN, SIMILAR DETAILS OF CONSTRUCTION SHALL BE USED.
STRUCTURAL DRAWINGS SHALL BE USED IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS AND ALL OTHER CONTRACT DOCUMENTS FOR BIDDING AND CONSTRUCTION. CONTRACTOR SHALL VERIFY DIMENSIONS AND CONDITIONS FOR COMPATIBILITY AND SHALL NOTIFY THE CONTRACTING OFFICER OF ALL DISCREPANCIES PRIOR TO CONSTRUCTION.
DISCREPANCIES: IN CASE OF DISCREPANCIES BETWEEN DRAWINGS, SPECIFICATIONS, REFERENCE STANDARDS, OR GOVERNING CODE, THE MORE STRINGENT REQUIREMENTS SHALL GOVERN. CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER OF DISCREPANCIES AND OBTAIN DIRECTION PRIOR TO PROCEEDING. NOTES ON INDIVIDUAL STRUCTURAL DRAWINGS SHALL TAKE PRIORITY OVER GENERAL STRUCTURAL NOTES. DIMENSIONS
NOTED IN THE DRAWINGS SHALL BE FOLLOWED. DO NOT SCALE DRAWINGS.
SPECIFICATIONS: REFER TO SPECIFICATIONS FOR INFORMATION IN ADDITION TO THESE NOTES AND DRAWINGS.
ARCHITECTURAL: REFER TO ARCHITECTURAL DRAWINGS FOR ELEVATIONS, SLOPES, DEPRESSIONS, NON- BEARING WALLS, FASCIA, ELEVATORS, STAIRS, CURBS, DRAINS, RAILINGS, WATERPROOFING, FINISHES, ETC.
CONTRACTOR-INITIATED CHANGES: SHALL BE SUBMITTED IN WRITING TO THE CONTRACTING OFFICER FOR APPROVAL AS REQUIRED BY THE DIVISION 01 SPECIFICATIONS PRIOR TO FABRICATION AND CONSTRUCTION.
CHANGES SHOWN ON SHOP DRAWINGS OR SUBMITTALS ONLY WILL NOT SATISFY THIS REQUIREMENT.
CONTRACTOR RESPONSIBILITIES: DRAWINGS REPRESENT DESIGN OF STRUCTURE IN COMPLETED FORM.
CONTRACTOR SHALL BE RESPONSIBLE FOR METHODS, SEQUENCES, AND SAFETY PRECAUTIONS REQUIRED TO
PERFORM WORK.
CONTRACTOR SHALL DESIGN AND PROVIDE TEMPORARY SHORING AND BRACING OF ALL STRUCTURAL MEMBERS, EXISTING CONSTRUCTION, AND SOIL EXCAVATION AS REQUIRED. SHORING AND BRACING SHALL NOT BE REMOVED UNTIL ALL FINAL CONNECTIONS HAVE BEEN COMPLETED IN ACCORDANCE WITH THE DRAWINGS, AND MATERIALS
HAVE ACHIEVED DESIGN STRENGTH.
STRUCTURAL OBSERVATION SHALL BE PERFORMED PER IBC SECTION 1704.6
SPECIAL INSPECTION PER IBC SECTION 1704, SHALL BE PERFORMED BY AN AGENCY APPROVED BY THE CONTRACTING OFFICER AS REQUIRED BY THE DIVISION 01 SPECIFICATIONS AND AS OUTLINED IN THE STRUCTURAL SPECIAL
INSPECTION SCHEDULE ON SHEETS S0.3 AND S0.4.
CODES
BUILDING CODE: ALL MATERIALS, WORKMANSHIP, DESIGN, AND CONSTRUCTION SHALL CONFORM TO THE DRAWINGS, SPECIFICATIONS AND THE INTERNATIONAL BUILDING CODE (IBC), 2015 EDITION.
RISK CATEGORY: II (IBC TABLE 1604.5)
STANDARDS: REFERENCE TO ASTM AND OTHER STANDARDS SHALL MEAN THE LATEST EDITION REFERENCED IN THE 2015 IBC, UNLESS NOTED IN THESE DOCUMENTS OR DESIGNATED BY THE GOVERNING CODE.
DESIGN CRITERIA
SNOW DESIGN DATA:
GROUND SNOW LOAD Pg = 490 PSF (ASCE 7 FIGURE 7-1)
FLAT-ROOF SNOW LOAD Pf = 412 PSF (ASCE 7 SECTION 7.3)
SNOW EXPOSURE FACTOR Ce = 1.0 (ASCE 7 TABLE 7-2)
SNOW LOAD IMPORTANCE FACTOR I S = 1.0 (ASCE 7 SECTION 7.3.3)
THERMAL FACTOR Ct = 1.2 (ASCE 7 TABLE 7-3)
ROOF EXPOSURE PARTIALLY EXPOSED (ASCE 7 TABLE 7-2)
TERRAIN CATEGORY C (ASCE 7 SECTION 26.7)
DESIGN ROOF SLOPE 11/2" VERT TO 12" HORIZ
ROOF SLOPE FACTOR Cs = 1.0 (ASCE 7 SECTION 7.4)
SLOPED ROOF SNOW LOAD Ps = 412 PSF (ASCE SECTION 7.4)
WIND DESIGN DATA:
WIND BASE SHEAR VW (N-S) = 50.5 KIPS
VW (E-W) = 14.3 KIPS
ANALYTICAL PROCEDURE DIRECTIONAL PROCEDURE, ASCE 7 CHAPTER 27
TYPE OF STRUCTURE RIGID (ASCE 7 SECTION 26.9.2)
BASIC WIND SPEED V = 115 MPH, ULTIMATE 3 SECOND GUST (ASCE 7 FIG 26.5-1A - 26.5-1C)
VASD = 89 MPH, NOMINAL 3 SECOND GUST (IBC EQUATION 16-33)
EXPOSURE CATEGORY C (ASCE 7 SECTION 26.7.3)
INTERNAL PRESSURE COEFFICIENT 0.0 (ASCE 7 FIGURE 26.11-1)
ENCLOSURE CLASSIFICATION OPEN (ASCE 7 SECTION 26.10.1)
DIRECTIONALITY FACTOR Kd = 0.85 : MWFRS
(ASCE 7 TABLE 26.6-1)
TOPOGRAPHIC FACTOR Kzt = 1 (ASCE 7 SECTION 26.8)
GUST EFFECT FACTOR G = 0.85 (ASCE 7 SECTION 26.9.1)
EARTHQUAKE DESIGN DATA:
SEISMIC-FORCE-RESISTING SYSTEM: STEEL ORDINARY
MOMENT FRAMES
ANALYTICAL PROCEDURE: EQUIVALENT LATERAL
FORCE PROCEDURE
SEISMIC BASE SHEAR: VE (N-S) = 63.6 KIPS
(ASCE 7 SECTION 12.8.1) VE (E-W) = 63.6 KIPS
SEISMIC RESPONSE COEFFICIENT: CS (N-S) = 0.145
(ASCE 7 SECTION 12.8.1.1) CS (E-W) = 0.145
SEISMIC IMPORTANCE FACTOR Ie 1.0 (ASCE 7 TABLE 1.5-2)
SITE CLASS D (ASCE 7 SECTION 11.4.2)
SS = 0.56 (ASCE 7 SECTION 11.4.1)
S1 = 0.27 (ASCE 7 SECTION 11.4.1)
SDS = 0.51 (ASCE 7 SECTION 11.4.4)
SD1 = 0.34 (ASCE 7 SECTION 11.4.4)
SEISMIC DESIGN CATEGORY D (ASCE 7 SECTION 11.6)
RESPONSE MODIFICATION COEFFICIENT R = 3.5 (ASCE 7 TABLE 12.2-1)
SYSTEM OVERSTRENGTH FACTOR Ω0 = 3.0 (ASCE 7 TABLE 12.2-1)
DEFLECTION AMPLIFICATION FACTOR Cd = 3.0 (ASCE 7 TABLE 12.2-1)
GEOTECHNICAL
ALLOWABLE SOIL PRESSURE, LATERAL EARTH PRESSURE, AND SOIL PROFILE TYPE ARE ASSUMED AND THEREFORE MUST BE VERIFIED BY THE CONTRACTOR'S GEOTECHNICAL ENGINEER OR INSPECTOR. IF SOILS ARE FOUND TO BE OTHER THAN ASSUMED OR FOUND TO BE EXPANSIVE, NOTIFY THE CONTRACTING OFFICER FOR
POSSIBLE FOUNDATION REDESIGN.
FOOTINGS SHALL BEAR ON FIRM, UNDISTURBED EARTH OR CONTROLLED, COMPACTED STRUCTURAL FILL AT LEAST 18" BELOW LOWEST ADJACENT EXTERIOR FINISHED GRADE. FOOTING DEPTHS AND ELEVATIONS SHOWN ON DRAWINGS ARE MINIMUM AND FOR GUIDANCE ONLY; CONTRACTOR SHALL ESTABLISH ACTUAL ELEVATIONS IN FIELD. BACKFILL BEHIND ALL WALLS WITH FREE DRAINING, GRANULAR FILL AND PROVIDE FOR SUBSURFACE
DRAINAGE IN AN APPROVED MANNER.
SOIL PROFILE TYPE SITE CLASS "D"
ALLOWABLE VERTICAL DESIGN PRESSURE 2,500 PSF
ALLOWABLE PASSIVE PRESSURE 150 PCF
ALLOWABLE FRICTION COEFFICIENT 0.25
CONCRETE:
REFERENCE STANDARDS: CONCRETE SHALL CONFORM TO ALL REQUIREMENTS OF THE FOLLOWING DOCUMENTS, EXCEPT AS MODIFIED BELOW:
ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE"
ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE"
ACI 304 "GUIDE FOR MEASURING, MIXING, TRANSPORTING, AND PLACING CONCRETE"
ACI 311 "GUIDE FOR CONCRETE INSPECTION"
ACI SP-15* "FIELD REFERENCE MANUAL"
* A COPY SHALL BE KEPT IN THE CONTRACTOR'S FIELD OFFICE AT ALL TIMES.
MATERIALS:
CEMENT ASTM C150, C595
*AGGREGATES ASTM C33
ADMIXTURES ASTM C260, C494, C1017
* *FLY ASH ASTM C618, CLASS F OR C
* AGGREGATES THAT EXHIBIT DELETERIOUS ACTIVITY WHEN EVALUATED IN ACCORDANCE WITH ASTM C33 APPENDIX XI SHALL NOT BE USED. THE 'SAND EQUIVALENT' FOR FINE AGGREGATE SHALL NOT BE LESS THAN 75.
* * MAXIMUM LOSS ON IGNITION SHALL BE 1%.
CONCRETE MIXES SHALL BE PROPORTIONED TO ACHIEVE A WORKABLE MIX THAT CAN BE PLACED WITHOUT SEGREGATION OR EXCESS FREE SURFACE WATER. MIX DESIGNS SHALL BE SUBMITTED TO THE CONTRACTING OFFICER FOR REVIEW BY ENGINEER PRIOR TO USE. COMPLY WITH IBC SECTION 1904. MIXES SHALL MEET OR
EXCEED THE FOLLOWING CRITERIA:
TYPE OF CONSTRUCTION
SPECIFIED COMPRESSIVE MAXIMUM EXPOSURE CLASS
STRENGTH (f 'c) WATER/CEMENT (ACI 318-14 TABLES
AT 28 DAYS, UNO RATIO 19.3.1.1 AND 19.3.2.1)
BELOW-GRADE CONCRETE 4,500 PSI 0.45 F2, S0, W0, C1
(FOOTINGS)
MISCELLANEOUS EXTERIOR CONCRETE 4,500 PSI 0.45 F2, S0, W0, C1
(EXTERIOR SLABS AND SITE WALLS)
CONCRETE MIXES SHALL MEET OR EXCEED THE REQUIREMENTS SPECIFIED ABOVE. MIXES SHALL BE SUBMITTED TO THE CONTRACTING OFFICER FOR APPROVAL TWO WEEKS PRIOR TO PLACING ANY CONCRETE AND SHALL INCLUDE THE AMOUNTS OF CEMENT, CEMENTITIOUS MATERIAL, FINE AND COARSE AGGREGATE, WATER AND ADMIXTURES, AS WELL AS THE WATER-CEMENT RATIO, SLUMP, CONCRETE YIELD AND SUBSTANTIATING STRENGTH DATA IN ACCORDANCE WITH ACI 318, CHAPTER 26. REVIEW OF MIX SUBMITTALS BY THE ENGINEER OF RECORD INDICATES ONLY THAT INFORMATION PRESENTED CONFORMS GENERALLY WITH CONTRACT DOCUMENTS. CONTRACTOR OR SUPPLIER MAINTAINS FULL
RESPONSIBILITY FOR SPECIFIED PERFORMANCE.
ADMIXTURES: ALL CONCRETE, INCLUDING SLABS ON GRADE, SHALL HAVE A WATER-REDUCING ADMIXTURE COMPLYING WITH ASTM C494 ADDED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS. CALCIUM CHLORIDE OR OTHER
CHLORIDE ADMIXTURES SHALL NOT BE USED.
ALL HORIZONTAL SURFACES EXPOSED TO WEATHER SHALL CONTAIN AN AIR-ENTRAINING AGENT COMPLYING WITH ASTM C260. THE AMOUNT OF ENTRAINED AIR SHALL BE IN ACCORDANCE WITH ACI 318-14 TABLE 19.3.3.1. TESTS FOR AIR CONTENT SHALL BE MADE AT THE DISCHARGE END OF THE TRUCK'S PLACING HOSE IN ACCORDANCE WITH ASTM C173.
RE
GI
ST
ERE
D PROFESSIONA
L
PAUL N. CROCK
ER
ENGI
NEER
JAN. 14,2003
OREGON
72398PE
STR
UCTURAL
EXPIRES 12/31/21
SHEET
PMIS/PKG NO.
DRAWING NO.
142813
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
KAO, HM
RLC
PNC
TVC
SNOW ROOF
CRATER LAKE NATIONAL PARK OF 2211
/1
7/
:2 7:
P
M C
:\M Y
C ra p\ R ev it
Lo ca l F ile s\
\6
N P
S C ra te r La ke T
V C
\2
4_
-0
_C
R
LA
_T V
C _S
T R
U _R
LC
.r vt
S0.1
2020.11.20
CRLA 198641GENERAL STRUCTURAL NOTES
AND SHEET INDEX
WATER/CEMENT RATIO SHALL BE MEASURED BY WEIGHT AND BE BASED ON TOTAL CEMENTITIOUS MATERIAL, INCLUDING CEMENT AND POZZOLANS SUCH AS FLY ASH AND SILICA FUME.
MAXIMUM AGGREGATE SIZE SHALL BE 1", BUT NOT MORE THAN 3/4 TIMES THE CLEAR DISTANCE BETWEEN REINFORCING BARS NOR 1/5 TIMES THE NARROWEST DIMENSION BETWEEN SIDES OF FORMS. MAXIMUM
AGGREGATE SIZE FOR SLABS ON GRADE SHALL BE 1/3 TIMES THE SLAB THICKNESS.
SLUMP REQUIRED FOR PROPER PLACEMENT SHALL BE DETERMINED BY CONTRACTOR AND SUPPLIER, AND INCLUDED IN MIX DESIGN SUBMITTALS. FIELD MEASURED SLUMP SHALL CONFORM TO SUBMITTED CONCRETE
MIX DESIGN. SLUMP SHALL CONFORM TO ASTM C94.
MASS CONCRETE:
CONCRETE PLACED IN MONOLITHIC PLACEMENTS WHERE THE MINIMUM OF ALL THREE DIMENSIONS EXCEEDS 2'-6" SHALL BE CONSIDERED "MASS CONCRETE" AND SHALL BE SUBJECT TO THE APPLICABLE REQUIREMENTS
OF ACI 301, CHAPTER 8.
ASTM C150 TYPE III CEMENT IS PROHIBITED. UNLESS OTHERWISE SPECIFIED, USE MODERATE OR LOW HEAT OF HYDRATION CEMENT, BLENDED HYDRAULIC CEMENT WITH MODERATE OR LOW HEAT OF HYDRATION PROPERTIES, OR PORTLAND CEMENT WITH FLY ASH, POZZOLAN, OR GROUND-GRANULATED BLAST-FURNACE SLAG. ADDITIVES CONTAINING CALCIUM CHLORIDE ARE PROHIBITED. APPROVED RETARDING, RETARDING HIGH-RANGE WATER
REDUCING, OR RETARDING PLASTICIZING ADMIXTURE SHALL BE USED.
THE TEMPERATURE OF CONCRETE AT TIME OF PLACEMENT SHALL NOT EXCEED 90 DEGREES FAHRENHEIT PER ASTM C94. THE AMBIENT TEMPERATURE AT TIME OF PLACEMENT SHALL NOT EXCEED 90 DEGREES FAHRENHEIT OR BE LESS THAT 35 DEGREES FAHRENHEIT. THE MAXIMUM INTERNAL TEMPERATURE DURING CURING SHALL NOT EXCEED 160 DEGREES FAHRENHEIT. CONFORM TO THE REQUIREMENTS OF ACI 305.1 AND ACI 306.1 FOR HOT- WEATHER AND COLD-WEATHER CONCRETING, RESPECTIVELY. IF COOLING METHODS ARE EMPLOYED, THEY SHALL NOT INCREASE THE WATER-CEMENT RATIO OR SLUMP BEYOND ALLOWABLE LIMITS. THE CONCRETE SHALL BE COOLED GRADUALLY SO THAT THE SURFACE TEMPERATURE DROP DOES NOT EXCEED 20 DEGREES FAHRENHEIT
IN ANY 24-HOUR PERIOD AFTER PLACEMENT.
SUBMIT DETAILED PROCEDURES, MATERIALS, MIX DESIGNS, AND THE TEST RESULTS INCLUDING HEAT OF HYDRATION TEST DATA PER ASTM C186 TO THE CONTRACT OFFICER BEFORE CONSTRUCTION OF MASS CONCRETE.
EMBEDDED ITEMS: CONDUIT AND SLEEVES SHALL NOT BE EMBEDDED IN OR PASS THROUGH CONCRETE WITHOUT APPROVAL. ALUMINUM ITEMS SHALL NOT BE EMBEDDED IN CONCRETE. SUBMIT CONDUIT LAYOUT AND EMBEDDED ITEM PLANS TO THE CONTRACTING OFFICER FOR REVIEW BY ENGINEER PRIOR TO PLACING CONCRETE.
NON-SHRINK GROUT SHALL HAVE A MINIMUM COMPRESSIVE STRENGTH OF 6,000 PSI AT 28 DAYS, BUT NOT LESS
THAN THE MATERIAL ON WHICH IT IS PLACED UPON.
CONSTRUCTION JOINTS IN WALLS SHALL BE KEYED IN ACCORDANCE WITH TYPICAL CONSTRUCTION JOINT DETAILS SHOWN ON DRAWINGS OR, AT CONTRACTOR'S OPTION, SHALL BE AN INTENTIONALLY ROUGHENED
CONSTRUCTION JOINT DEFINED BY THE FOLLOWING:
1. SURFACE OF JOINT SHALL BE SAND BLASTED OR ROUGHENED WITH A CHIPPING HAMMER TO EXPOSE
AGGREGATEEMBEDDED IN PREVIOUS POUR.
2. EXPOSED AGGREGATE SHALL PROTRUDE 1/4" MINIMUM.
3. JOINT SURFACE SHALL BE CLEANED AND LAITANCE REMOVED.
4. JOINT SHALL BE WETTED AND STANDING WATER REMOVED IMMEDIATELY BEFORE NEW CONCRETE IS
PLACED.
5. SUBMIT CONSTRUCTION JOINT LAYOUT PLAN TO THE CONTRACTING OFFICER FOR REVIEW BY ENGINEER
PRIOR TO PLACING CONCRETE.
COORDINATION: SEE ARCHITECTURAL DRAWINGS FOR LOCATIONS AND DIMENSIONS OF DOOR AND WINDOW OPENINGS IN CONCRETE WALLS. SEE MECHANICAL DRAWINGS FOR SIZE AND LOCATION OF MISCELLANEOUS MECHANICAL OPENINGS THROUGH CONCRETE CONSTRUCTION. SEE ARCHITECTURAL DRAWINGS FOR ALL GROOVES, NOTCHES, CHAMFERS, FEATURE STRIPS, COLOR, TEXTURE, AND OTHER FINISH DETAILS AT EXPOSED
CONCRETE SURFACES.
CONCRETE REINFORCEMENT
REFERENCE STANDARDS: CONCRETE REINFORCEMENT SHALL CONFORM TO ALL REQUIREMENTS OF THE
FOLLOWING CODES, SPECIFICATIONS, AND STANDARDS, EXCEPT AS MODIFIED BELOW:
ACI 301 "SPECIFICATIONS FOR STRUCTURAL CONCRETE"
ACI SP-66 "ACI DETAILING MANUAL"
ACI 318 "BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE"
CRSI "PLACING REINFORCING BARS"
CRSI "MANUAL OF STANDARD PRACTICE" MSP-1
WRI "WELDED WIRE FABRIC MANUAL OF STANDARD PRACTICE"
MATERIALS:
DEFORMED BARS ASTM A615, GRADE 60
REINFORCEMENT SHALL BE PLACED AND SUPPORTED IN ACCORDANCE WITH CRSI MSP-1. REINFORCEMENT SHALL BE DETAILED IN ACCORDANCE WITH ACI SP-66. NO BENDING OR STRAIGHTENING OF REINFORCEMENT WILL BE
PERMITTED AFTER PARTIAL EMBEDMENT IN CONCRETE.
LAP SPLICE ALL CONTINUOUS REINFORCEMENT IN ACCORDANCE WITH REINFORCEMENT SPLICE AND DEVELOPMENT LENGTH SCHEDULE. PROVIDE CORNER BARS AT ALL WALL AND FOOTING INTERSECTIONS. LAP ADJACENT MATS OF WELDED WIRE FABRIC A MINIMUM OF 1 CROSS WIRE SPACING + 2" OR 8" WHICHEVER IS GREATER.
NO BARS PARTIALLY EMBEDDED IN HARDENED CONCRETE SHALL BE FIELD BENT UNLESS OTHERWISE NOTED ON
THE DRAWINGS OR APPROVED BY THE ENGINEER OF RECORD.
WELDING OR TACK WELDING OF REINFORCING BARS TO OTHER BARS OR TO PLATES, ANGLES, ETC IS PROHIBITED, EXCEPT WHERE SPECIFICALLY NOTED IN DETAILS. WHERE WELDING IS NOTED, IT SHALL BE DONE BY AWS CERTIFIED WELDERS USING E9018 ELECTRODES. WELDING PROCEDURES SHALL COMPLY WITH AWS-D1.4.
CONCRETE COVER: UNLESS NOTED OTHERWISE, MINIMUM CONCRETE COVER FOR REINFORCEMENT SHALL BE:
FOOTINGS 3" (EXCEPT 2" TOP AND FORMED SIDES)
CONCRETE ANCHORAGE
EXPANSION BOLTS INTO CONCRETE SHALL BE ONE OF THE FOLLOWING. INSTALL PER MANUFACTURER'S INSTRUCTIONS AND APPLICABLE IAPMO OR ICC-ES REPORTS. NOMINAL EMBEDMENT DEPTH SHALL BE AS NOTED
BELOW, UNLESS NOTED OTHERWISE.
HILTI KWIK BOLT TZ (ESR-1917)
3/8" EXPANSION BOLTS 2 5/16"
1/2" EXPANSION BOLTS 3 5/8"
5/8" EXPANSION BOLTS 4 7/16"
3/4" EXPANSION BOLTS 5 9/16"
SIMPSON STRONG-BOLT 2 (ESR 3037)
3/8" EXPANSION BOLTS 2 7/8"
1/2" EXPANSION BOLTS 3 7/8"
5/8" EXPANSION BOLTS 5 1/8"
3/4" EXPANSION BOLTS 5 3/4"
DEWALT POWER STUD+ SD2 (ESR 2502)
3/8" EXPANSION BOLTS 2 3/8"
1/2" EXPANSION BOLTS 3 3/4"
5/8" EXPANSION BOLTS 4 7/8"
3/4" EXPANSION BOLTS 5 3/4"
EPOXY-GROUTED RODS OR REBAR TO CONCRETE SHALL BE GROUTED WITH ONE OF THE FOLLOWING:
HILTI HIT-RE 500-V3 (ESR 3814), HILTI HIT-HY200 (ESR-3187), SIMPSON SET-XP (ESR 2508), OR DEWALT PURE110+ (ESR-3298). INSTALL PER MANUFACTURER'S INSTRUCTIONS AND APPLICABLE IAPMO OR ICC-ES REPORTS. EMBEDMENT DEPTHS SHALL BE AS NOTED BELOW, UNLESS NOTED OTHERWISE.
3/8" ROD OR #3 BAR 4"
1/2" ROD OR #4 BAR 5"
5/8" ROD OR #5 BAR 7"
3/4" ROD OR #6 BAR 9"
7/8" ROD OR #7 BAR 12"
1" ROD OR #8 BAR 15"
HEAVY DUTY SCREW ANCHORS INTO CONCRETE SHALL BE SIMPSON TITEN HD (ESR-2713)
DEWALT SCREW-BOLT+ (ESR-3889) OR HILTI KWIK HUS EZ (ESR-3027).
DRIVE PINS AND OTHER POWDER-ACTUATED FASTENERS SHALL BE ITW RAMSET/RED HEAD (ESR-1799), HILTI XU LOW VELOCITY (ESR-2269), OR DEWALT POWER ACTUATED FASTENERS (ESR-2024)
UNDERCUT ANCHORS SHALL BE USP DUC (ESR-1970), HILTI HDA (ESR-1546) OR
POWERS ATOMIC+ UNDERCUT ANCHOR (ESR-3067).
POST-INSTALLED ANCHORS SHALL NOT BE USED AS SUBSTITUTES FOR CAST-IN-PLACE ANCHOR BOLTS OR REINFORCING STEEL UNLESS SPECIFICALLY APPROVED BY THE STRUCTURAL ENGINEER OF RECORD.
PRODUCT SUBSTITUTES PROPOSED BY THE CONTRACTOR SHALL BE SUBMITTED FOR REVIEW WITH IAPMO OR
ICC-ES REPORTS INDICATING EQUIVALENT OR GREATER LOAD CAPACITIES.
NO REINFORCING BARS SHALL BE CUT TO PLACE POST-INSTALLED ANCHORS. ALL DEFECTIVE ANCHOR HOLES SHALL BE GROUTED WITH EPOXY ADHESIVE AND A NEW HOLE DRILLED A MINIMUM OF 3 BOLT DIAMETERS AWAY.
STEEL
REFERENCE STANDARDS: STRUCTURAL STEEL SHALL CONFORM TO ALL REQUIREMENTS OF THE FOLLOWING
DOCUMENTS:
AISC 360 "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS"
AISC 341 "SEISMIC PROVISIONS FOR STRUCTURAL STEEL BUILDINGS"
AISC 303 "CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES"
AWS D1.1 "STRUCTURAL WELDING CODE - STEEL"
AISC 348 "SPECIFICATION FOR STRUCTURAL JOINTS USING ASTM A325 OR A490 BOLTS"
AISC 358 "PREQUALIFIED CONNECTIONS FOR SPECIAL AND INTERMEDIATE STEEL
MOMENT FRAMES FOR SEISMIC APPLICATIONS"
MATERIALS:
TYPE OF MEMBER ASTM SPECIFICATION YIELD
WIDE FLANGES (W), STRUCTURAL TEES (WT) A992 50 KSI
PLATES, ANGLES, CHANNELS A36 36 KSI
THREADED RODS (TR) AND BARS
SPECIAL SHAPES (NOTED A572 50 KSI
GRADE 50 ON DRAWINGS)
MACHINE BOLTS (MB) A307
CONNECTION BOLTS (HSB) A325: F3125, GRADE A325
ANCHOR RODS (AR) F1554 GRADE 55, WELDABLE
TENSION CONTROL BOLTS F1852
LOAD-INDICATING WASHERS F959, TYPE A325
CAMBER: ALL MEMBERS SHALL BE ERECTED WITH NATURAL OR INDUCED CAMBER UPWARDS, UNLESS NOTED OTHERWISE. CAMBER INDICATED ON DRAWINGS SHALL BE AS DELIVERED TO THE JOB SITE. CONTRACTOR SHALL CONSIDER CAMBER LOSS DUE TO SHIPPING AND HANDLING. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL
ERECTION AIDS INCLUDING ERECTION ANGLES AND LIFT HOLES.
STRUCTURAL STEEL EXPOSED TO WEATHER SHALL BE ZINC-COATED HOT-DIPPED GALVANIZED PER ASTM A123.
ALL FIELD WELDS EXPOSED TO WEATHER SHALL BE COATED WITH BRUSH APPLIED PAINT CONTAINING ZINC DUST COMPLYING WITH ASTM A780. ALL BOLTS AND ANCHOR RODS EXPOSED TO WEATHER SHALL BE ZINC-COATED
HOT-DIPPED GALVANIZED PER ASTM A153.
BOLTED CONNECTIONS NOT SPECIFIED AS SLIP-CRITICAL NEED ONLY BE TIGHTENED TO AISC SNUG-TIGHT CRITERIA, UNLESS NOTED OTHERWISE. CONNECTION PLATES SHALL HAVE AISC STANDARD ROUND HOLES UNLESS NOTED OTHERWISE. ALL OVERSIZED OR SLOTTED HOLES SHALL HAVE WASHERS PROVIDED IN
ACCORDANCE WITH AISC 360, UNLESS NOTED OTHERWISE.
PRETENSIONED OR SLIP-CRITICAL CONNECTIONS SHALL USE LOAD-INDICATING WASHERS OR TENSION CONTROL BOLTS SUCH AS BETHLEHEM INDICATOR BOLTS, LeJEUNE TENSION CONTROL BOLTS, ETC.
CONNECTED PLIES SHALL BE PREPARED TO MEET THE REQUIREMENTS FOR CLASS A FAYING SURFACES.
WELDING: ALL WELDS SHALL COMPLY WITH AWS D1.1. WELDS SHALL BE MADE USING LOW HYDROGEN E70XX ELECTRODES.
ONLY AWS PREQUALIFIED WELDED JOINTS SHALL BE USED. SHOP DRAWINGS SHALL SHOW ALL WELDING WITH AWS A2.4 STANDARD SYMBOLS. WELDS SHOWN ON DRAWINGS ARE MINIMUM SIZES. INCREASE WELD SIZE TO AWS MINIMUM SIZES
BASED ON PLATE THICKNESS.
ALL WELDS SHALL BE MADE WITH A FILLER WELD METAL THAT HAS A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 20 FT.-LBS.
AT 0 DEGREES F. IN ADDITION TO MEETING THE ABOVE REQUIREMENTS, ALL WELDS INDICATED AS "DEMAND CRITICAL" SHALL BE MADE WITH MATERIAL WITH A MINIMUM CHARPY V-NOTCH TOUGHNESS OF 40 FT-LBS AT 70 DEGREES F. SEE AISC 341-10 CHAPTER A AND AWS D1.8 SECTION 6.3 FOR ADDITIONAL REQUIREMENTS. PROPOSED FILLER MATERIAL FOR BOTH SHOP
AND FIELD WELDS SHALL BE SUBMITTED FOR REVIEW PRIOR TO CONSTRUCTION.
WELDS SHOWN ON DRAWINGS ARE FOR FINAL CONNECTIONS. UNLESS FIELD WELD SYMBOLS ARE SHOWN, CONTRACTOR SHALL BE RESPONSIBLE FOR DETERMINING IF A WELD SHOULD BE SHOP OR FIELD WELDED IN ORDER TO FACILITATE
STEEL ERECTION.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL JOINT PREPARATIONS AND WELDING PROCEDURES, INCLUDING ROOT OPENINGS AND FACE DIMENSIONS, GROOVE ANGLES, BACKING BARS, COPES, WELD ACCESS HOLES, TAPERS, AND
SURFACE ROUGHNESS.
WELDER CERTIFICATION: AWS
FIREPROOFING: REFER TO SPECIFICATIONS FOR REQUIRED FIREPROOFING AND TO ARCHITECTURAL DRAWINGS FOR REQUIRED FIRE RESISTANCE RATINGS. STRUCTURAL FRAME CONSISTS OF THE COLUMNS; THE GIRDERS, BEAMS, TRUSSES, AND SPANDRELS HAVING DIRECT CONNECTIONS TO THE COLUMNS; AND BRACING MEMBERS DESIGNED TO
CARRY GRAVITY LOADS.
ANCHOR RODS SHALL BE INSTALLED TO AISC SNUG-TIGHT CRITERIA WITH HEX NUTS AND LOCK WASHERS OR JAM NUTS AT THE TOP. AT THE BOTTOM, PROVIDE A STANDARD SIZE HEAD, TACK-WELDED NUT OR DOUBLE NUT. NO HEATING OR BENDING OF ANCHOR RODS IS PERMITTED. ENLARGEMENT OF ANCHOR ROD HOLES BY BURNING IS NOT PERMITTED.
BASE PLATE HOLES FOR ANCHOR RODS SHALL BE AS SHOWN BELOW:
AR MAXIMUM HOLE MINIMUM WASHER MINIMUM WASHER
DIAMETER DIAMETER DIAMETER THICKNESS
5/8" 1 1/16" 1 1/2" 3/16"
3/4" 1 5/16" 2" 1/4"
7/8" 1 9/16" 2 1/2" 5/16"
1" 1 13/16" 3" 3/8"
STEEL DECK SIZE, TYPE, GAGE, AND ATTACHMENTS SHALL BE PROVIDED AS INDICATED IN THE DRAWINGS. STEEL DECK SHALL CONFORM TO THE REQUIREMENTS OF THE STEEL DECK INSTITUTE. CEILINGS, LIGHT FIXTURES, DUCTS, AND OTHER ITEMS SHALL NOT BE SUSPENDED FROM NON-COMPOSITE DECKS. STEEL DECK GAGES SHOWN ON THE DRAWINGS ARE BASED ON UNSHORED CONDITIONS. HEAVIER DECK GAGES MAY BE REQUIRED FOR SOME SPECIAL CONDITIONS. DECK SUPPLIER SHALL VERIFY DECK CAPACITY BASED ON ACTUAL DECK LAYOUT AND SPAN CONDITIONS. CONTRACTOR SHALL PROVIDE CLOSURE PLATES, FLASHING, AND ALL MISCELLANEOUS LIGHT GAGE METAL NECESSARY TO COMPLETE THE WORK.
DIMENSIONAL TOLERANCE FOR STRUCTURAL STEEL MEMBERS SHALL BE PER THE AISC CODE OF STANDARD PRACTICE FOR STEEL BUILDINGS AND BRIDGES, SECTION 6.4 AND ASTM SPECIFICATION A6. UNLESS SPECIFICALLY ALLOWED BY THE ENGINEER OF RECORD, COLUMN MEMBERS SHALL NOT BE MODIFIED BY THE ROTARY STRAIGHTENING PROCESS.
CONCRETE (CONTINUED):
RE
GI
ST
ERE
D PROFESSIONA
L
PAUL N. CROCK
ER
ENGI
NEER
JAN. 14,2003
OREGON
72398PE
STR
UCTURAL
EXPIRES 12/31/21
SHEET
PMIS/PKG NO.
DRAWING NO.
142813
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
KAO, HM
RLC
PNC
TVC
SNOW ROOF
CRATER LAKE NATIONAL PARK OF 2211
/1
7/
:2 7:
P
M C
:\M Y
C ra p\ R ev it
Lo ca l F ile s\
\6
N P
S C ra te r La ke T
V C
\2
4_
-0
_C
R
LA
_T V
C _S
T R
U _R
LC
.r vt
S0.2
2020.11.20
CRLA 198641
GENERAL STRUCTURAL NOTES
RE
GI
ST
ERE
D PROFESSIONA
L
PAUL N. CROCK
ER
ENGI
NEER
JAN. 14,2003
OREGON
72398PE
STR
UCTURAL
EXPIRES 12/31/21
SHEET
PMIS/PKG NO.
DRAWING NO.
142813
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
KAO, HM
RLC
PNC
TVC
SNOW ROOF
CRATER LAKE NATIONAL PARK OF 2211
/1
7/
:2 7:
P
M C
:\M Y
C ra p\ R ev it
Lo ca l F ile s\
\6
N P
S C ra te r La ke T
V C
\2
4_
-0
_C
R
LA
_T V
C _S
T R
U _R
LC
.r vt
S0.3
2020.11.20
CRLA 198641
SPECIAL INSPECTION SCHEDULES
SEISMIC WELDING
WELDING
BOLTING
REQUIRED VERIFICATION AND INSPECTION OF SOILS
STRUCTURAL STEEL SPECIAL INSPECTION
WELDER IDENTIFICATION SYSTEM 1
SEE EARTHQUAKE DESIGN DATA SECTION OF THE GENERAL STRUCTURAL NOTES FOR SEISMIC-FORCE RESISTING-SYSTEMS.
SEISMIC-FORCE-RESISTING SYSTEMS (INCLUDING DRAG STRUTS AND CHORDS) ARE SUBJECT TO SPECIAL INSPECTION IN ACCORDANCE WITH THE FOLLOWING SEISMIC AND NON-SEISMIC TABLES. STRUCTURAL SYSTEMS NOT PART OF THE SEISMIC-FORCE-RESISTING SYSTEM NEED ONLY BE INSPECTED IN ACCORDANCE WITH NON-SEISMIC TABLES.
AISC 360 CH. N
AND AWS D1.1
1705.2.1
DOCUMENT ACCEPTANCE OR REJECTION OF WELDED JOINT OR MEMBER
REPAIR ACTIVITIES
BACKING REMOVED AND WELD TABS REMOVED (IF REQUIRED)
k-AREA 2
PARC STRIKES
P P
WELDS MEET VISUAL ACCEPTANCE CRITERIA, CRACK PROHIBITION, WELD / BASE-METAL
FUSION, CRATER CROSS SECTION, WELD PROFILES, WELD SIZE, UNDERCUT, POROSITY
P PSIZE, LENGTH AND LOCATION OF WELDS
O OWELDS CLEANED
INSPECTION TASKS AFTER WELDING
INSPECTION TASKS AFTER WELDING
AISC 341 CH. J ,
AWS D1.1 , AND
AWS D1.8
1705.12.1
AISC 341 CH. J ,
AWS D1.1 , AND
AWS D1.8
1705.12.1
DP-PREPAIR ACTIVITIES
DPDP
BACKING REMOVED, WELD TABS REMOVED AND FINISHED,
AND FILLET WELDS ADDED (IF REQUIRED)
DPDP
DPDP
-P-P
-O-O
PLACEMENT OF REINFORCING OR CONTOURING
FILLET WELDS (IF REQUIRED)
- CRACK PROHIBITION
- WELDS MEET VISUAL ACCEPTANCE CRITERIA
- CRATER CROSS SECTION
- WELD PROFILES AND SIZE
- UNDERCUT
- POROSITY
WELDS MEET VISUAL ACCEPTANCE CRITERIA
SIZE, LENGTH, AND LOCATION OF WELDS
DOCTASKDOCTASK
QAQC
WELDS CLEANED
VISUAL INSPECTION TASK AFTER TO WELDING
-O-ONO WELDING OVER CRACKED TACKS
-O-O
- INTERPASS AND FINAL CLEANING
- EACH PASS WITHIN PROFILE LIMITATIONS
- EACH PASS MEET QUALITY REQUIREMENTS
WELDING TECHNIQUES
-O-O- WIND SPEED WITHIN LIMITS
- PRECIPITATION AND TEMPERATURE
ENVIRONMENTAL CONDITIONS
-O-O- PACKAGING
- EXPOSURE CONTROL
CONTROL AND HANDLING OF WELDING CONSUMABLES
-O-O
* * FOLLOWING PERFORMANCE OF THIS INSPECTION TASK FOR TEN WELDS TO BE MADE BY A GIVEN WELDER, WITH THE WELDER DEMONSTRATING UNDERSTANDING OF REQUIREMENTS AND POSSESSION OF SKILLS AND TOOLS TO VERIFY THESE ITEMS, THE PERFORM DESIGNATION OF THIS TASK SHALL BE REDUCED TO OBSERVE, AND THE WELDER SHALL PERFORM THIS TASK. SHOULD THE INSPECTOR DETERMINE THAT THE WELDER HAS DISCONTINUED PERFORMANCE OF THIS TASK, THE TASK SHALL BE RETURNED TO PERFORM UNTIL SUCH TIME AS THE INSPECTOR HAS RE-ESTABLISHED ADEQUATE ASSURANCE THAT THE WELDER WILL
PERFORM THE INSPECTION TASKS LISTED.
-O-OCONFIGURATION AND FINISH TO ACCESS HOLES
- SETTINGS ON WELDING EQUIPMENT
- TRAVEL SPEED
- SELECTED WELDING MATERIALS
- SHIELDING GAS TYPE / FLOW RATE
- PREHEAT APPLIED
- INTERPASS TEMPERATURE MAINTAINED (MINIMUM / MAXIMUM)
- PROPER POSITION (F , V , H , OH)
- INTERMIX OF FILTER METALS AVOIDED UNLESS APPROVED
WPS FOLLOWED
DOCTASKDOCTASK
QAQC
VISUAL INSPECTION TASK DURING TO WELDING
-O-O
-O-P / O * *
-O-P / O * *
-O-O
-O-O
- DIMENSION (ALIGNMENT, GAPS OF ROOT)
- CLEANLINESS (CONDITION OF STEEL SURFACES)
- TACKING (TACK WELD QUALITY AND LOCATION)
FIT-UP OF GROOVE (INCLUDING JOINT GEOMETRY)
CONFIGURATION AND FINISH TO ACCESS HOLES
- JOINT PREPARATION
- DIMENSION (ALIGNMENT, ROOF OPENING, ROOT FACE, BEVEL)
- CLEANLINESS (CONDITION OF STEEL SURFACES)
- TACKING (TACK WELD QUALITY AND LOCATION)
- BACKING TYPE AND FIT (IF APPLICABLE)
FIT-UP OF GROOVE (INCLUDING JOINT GEOMETRY)
WELDER IDENTIFICATION SYSTEM
DOCTASKDOCTASK
QAQC
MATERIAL IDENTIFICATION (TYPE / GRADE)
VISUAL INSPECTION TASK PRIOR TO WELDING
CONTINUOUS PERIODIC
AISC 360 CH. N
AND AWS D1.1
1705.2.1
AISC 360 CH. N
AND AWS D1.1
1705.2.1
AISC 360 CH. N 1705.2.1
AISC 360 CH. N 1705.2.1
AISC 360 CH. N 1705.2.1
P PDOCUMENT ACCEPTANCE OR REJECTION OF BOLTED CONNECTIONS
QC QAINSPECTION TASKS AFTER BOLTING
INSPECTION TASKS AFTER BOLTING
1705.6
1705.6
1705.6
1705.6
1705.6
IBC
REFERENCE
REFERENCE
STANDARD
X-
5. PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT SUBGRADE
AND VERIFY THAT SITE HAS BEEN PREPARED PROPERLY
-X
4. VERIFY USE OF PROPER MATERIALS, DENSITIES AND LIFT
THICKNESSES DURING PLACEMENT AND COMPACTION OF
COMPACTED FILL
3. PERFORM CLASSIFICATION AND TESTING OF COMPACTED FILL
MATERIALS
2. VERIFY EXCAVATIONS ARE EXTENDED TO PROPER DEPTH AND
HAVE REACHED PROPER MATERIAL
X-
1. VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE
ADEQUATE TO ACHIEVE THE DESIGN BEARING CAPACITY
VERIFICATION AND INSPECTION TASK
O O
FASTENERS ARE PRETENSIONED IN ACCORDANCE WITH THE RCSC SPECIFICATION,
PROGRESSING SYSTEMATICALLY FROM THE MOST RIGID POINT TOWARD THE FREE EDGES
O OFASTENER COMPONENT NOT TURNED BY THE WRENCH PREVENTED FROM ROTATING
O OJOINT BROUGHT TO THE SNUG-TIGHT CONDITION PRIOR TO THE PRETENSIONING OPERATION
O O
FASTENER ASSEMBLIES, OF SUITABLE CONDITION, PLACED IN ALL HOLES AND WASHERS
(IF REQUIRED) ARE POSITIONED AS REQUIRED
QC QAINSPECTION TASKS DURING BOLTING
INSPECTION TASKS DURING BOLTING
O O
PROPER STORAGE PROVIDED FOR BOLTS, NUTS, WASHERS AND OTHER FASTENER
COMPONENTS
PRE-INSTALLATION VERIFICATION TESTING BY INSTALLATION PERSONNEL OBSERVED
AND DOCUMENTED FOR FASTENER ASSEMBLIES AND METHODS USED
CONNECTING ELEMENTS, INCLUDING THE APPROPRIATE FAYING SURFACE CONDITION
AND HOLE PREPARATION, IF SPECIFIED, MEET APPLICABLE REQUIREMENTS
PROPER BOLTING PROCEDURE SELECTED FOR JOINT DETAIL
O O
PROPER FASTENERS SELECTED FOR THE JOINT DETAIL (GRADE, TYPE, BOLT LENGTH IF
THREADS ARE TO BE EXCLUDED FROM SHEAR PLANE)
O OFASTENERS MARKED IN ACCORDANCE WITH ASTM REQUIREMENTS
O PMANUFACTURER'S CERTIFICATIONS AVAILABLE FOR FASTENER MATERIALS
QC QAINSPECTION TASKS PRIOR TO BOLTING
INSPECTION TASKS PRIOR TO BOLTING
WELDING TECHNIQUES, INTERPASS AND FINAL CLEANING, EACH PASS WITHIN PROFILE
LIMITATIONS, EACH PASS MEETS QUALITY REQUIREMENTS
WPS FOLLOWED, SETTINGS ON WELDING EQUIPMENT, TRAVEL SPEED, SELECTED
WELDING MATERIALS, SHIELDING GAS TYPE / FLOW RATE, PREHEAT APPLIED, INTERPASS
TEMPERATURE MAINTAINED (MINIMUM / MAXIMUM), PROPER POSITION (F , V , H , OH)
O O
ENVIRONMENTAL CONDITIONS, WIND SPEED WITHIN LIMITS, PRECIPITATION AND
TEMPERATURE
NO WELDING OVER CRACKED TACK WELDS
CONTROL AND HANDLING OF WELDING CONSUMABLES, PACKAGING, EXPOSURE CONTROL
O OUSE OF QUALIFIED WELDERS
QC QAINSPECTION TASKS DURING WELDING
INSPECTION TASKS DURING WELDING
1 THE FABRICATOR OR ERECTOR, AS APPLICABLE, SHALL MAINTAIN A SYSTEM BY WHICH A WELDER WHO HAS WELDED A JOINT OR
MEMBER CAN BE IDENTIFIED. STAMPS, IF USED, SHALL BE THE LOW-STRESS TYPE.
O -CHECK WELDING EQUIPMENT
O OFIT-UP OF FILLET WELDS, DIMENSIONS (ALIGNMENT, GAPS AT ROOT), CLEANLINESS
(CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION)
O OCONFIGURATION AND FINISH OF ACCESS HOLES
O O
FIT-UP OF GROOVE WELDS (INCLUDING JOINT GEOMETRY), JOINT PREPARATION,
DIMENSIONS (ALIGNMENT, ROOT OPENING, ROOT FACE, BEVEL), CLEANLINESS
(CONDITION OF STEEL SURFACES), TACKING (TACK WELD QUALITY AND LOCATION),
BACKING TYPE AND FIT (IF APPLICABLE)
O OMATERIAL IDENTIFICATION (TYPE / GRADE)
MANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
P PWELDING PROCEDURE SPECIFICATIONS (WPSS) AVAILABLE
QC QAINSPECTION TASKS PRIOR TO WELDING
INSPECTION TASKS PRIOR TO WELDING
2 WHEN WELDING OF DOUBLER PLATES, CONTINUITY PLATES OR STIFFENERS HAS BEEN PERFORMED IN THE k-AREA, VISUALLY INSPECT THE WEB k-AREA FOR CRACKS WITHIN 3 INCHES OF WELD.
SPECIAL INSPECTION FOR STRUCTURAL STEEL SHALL BE ACCORDANCE WITH AISC 341, AISC 360, AND THE FOLLOWING INFORMATION.
TASK - INDICATES WHETHER TO OBSERVE OR PERFORM (OR BOTH) THE INSPECTION TASK.
DOC - THE INSPECTOR SHALL PREPARE REPORTS INDICATING THAT THE WORK HAS BEEN PERFORMED IN ACCORDANCE WITH
THE CONTRACT DOCUMENTS.
O - THESE FUNCTIONS ON A RANDOM, DAILY BASIS, OPERATIONS NEED NOT BE DELAYED PENDING INSPECTIONS. FREQUENCY
OF OBSERVATIONS SHALL BE ADEQUATE TO CONFIRM THAT THE WORK HAS BEEN PERFORMED INACCORDANCE WITH THE
APPLICABLE DOCUMENTS.
P - PERFORM, FOR EACH JOINT OR MEMBER PRIOR TO THE FINAL ACCEPTANCE OF THE ITEM.
QC - TASKS INDICATED AS "QC" SHALL BE EXECUTED BY THE FABRICATOR AND ERECTOR IN ACCORDANCE WITH AISC 360 CHAPTER N.
QA - TASKS INDICATED AS "QA" SHALL BE EXECUTED BY THE SPECIAL INSPECTOR IN ACCORDANCE WITH AISC 360 CHAPTER N.
STEEL DETAILS
REFERENCED
STANDARD
QC QA
INSPECT THE FABRICATED STEEL AND ERECTED STEEL FRAME TO VERIFY COMPLIANCE WITH
THE DETAILS SHOWN ON THE CONSTRUCTION DOCUMENTS, SUCH AS BRACES, STIFFENERS,
MEMBER LOCATIONS AND PROPER APPLICATION OF JOINT DETAILS AT EACH CONNECTION
INSPECTION TASKS
QC QA AISC 360 CH. N
IBC
REFERENCE
REFERENCED
STANDARD
IBC
REFERENCE
REFERENCED
STANDARD
IBC
REFERENCE
REFERENCED
STANDARD
O O
O O
P O
IBC
REFERENCE
REFERENCED
STANDARD
QC QA
P
P P
P P
P P
P P
IBC
REFERENCE
REFERENCED
STANDARD
IBC
REFERENCE
REFERENCED
STANDARD
O O
O O
O O
O O
P P
O O
IBC
REFERENCE
REFERENCED
STANDARD
IBC
REFERENCE
REFERENCED
STANDARD
IBC
REFERENCE
REFERENCED
STANDARD
AISC 341 CH. J ,
AWS D1.1 , AND
AWS D1.8
1705.12.1
-X-
-X-
SEISMIC REQUIREMENTS FOR NONSTRUCTURAL COMPONENTS
1 SPECIAL INSPECTION IS NOT REQUIRED FOR EXTERIOR CLADDING, INTERIOR AND EXTERIOR NONBEARING WALLS AND INTERIOR AND
EXTERIOR VENEER 30 FEET OR LESS IN HEIGHT ABOVE GRADE [ OR A WALKING SURFACE ].
2 SPECIAL INSPECTION IS NOT REQUIRED FOR EXTERIOR CLADDING AND INTERIOR AND EXTERIOR VENEER WEIGHING 5 PSF OR LESS.
SPECIAL INSPECTION IS NOT REQUIRED FOR INTERIOR NON-BEARING WALLS WEIGHING 15 PSF OR LESS.
d. INSTALLATION AND ANCHORAGE OF DUCTWORK
DESIGNED TO CARRY HAZARDOUS MATERIALS
a. ANCHORAGE OF STORAGE RACKS 8 FEET OR GREATER
IN HEIGHT
4. STORAGE RACK
e. INSTALLATION AND ANCHORAGE OF VIBRATION
ISOLATION SYSTEM WHERE THE NOMINAL CLEARANCE
BETWEEN THE EQUIPMENT SUPPORT FRAME AND
RESTRAIN IS 1/4 INCH OR LESS
X
c. INSTALLATION AND ANCHORAGE OF PIPING SYSTEM
DESIGNED TO CARRY HAZARDOUS MATERIALS AND
THERE ASSOCIATED MECHANICAL UNITS
1705.12.6-
b. ANCHORAGE OF OTHER ELECTRICAL EQUIPMENT
X 1705.12.4
ASCE 7
SECTION 13.2
X 1705.12.5-
X 1705.12.5-
X 1705.12.5.1-
X
a. ANCHORAGE OF ELECTRICAL EQUIPMENT FOR
EMERGENCY AND STANDBY POWER SYSTEMS
3. PLUMBING, MECHANICAL AND ELECTRICAL COMPONENTS
d. ANCHORAGE OF ACCESS FLOORS
c. ERECTION AND FASTENING OF INTERIOR AND
EXTERIOR VENEER 1 , 2
b. ERECTION AND FASTENING OF INTERIOR 3 AND
EXTERIOR NON-BEARING WALLS 1 , 2
a. ERECTION AND FASTENING OF
b. EXTERIOR CLADDING 1 , 2
2. ARCHITECTURAL COMPONENTS
1705.12.6
a. VERIFY THE LABEL, ANCHORAGE AND MOUNTING
CONFORMS TO THE CERTIFICATE OF COMPLIANCE
PERIODICCONTINUOUSVERIFICATION AND INSPECTION TASK
1. DESIGNATED SEISMIC SYSTEM
X 1705.12.5-
X 1705.12.6-
X 1705.12.6-
X 1705.12.6-
X 1705.12.7-
REFERENCED
STANDARD
IBC
REFERENCED
1. ALL SPECIAL INSPECTIONS TO BE PERFORMED BY THE CONTRACTOR'S THIRD PARTY SPECIAL INSPECTOR. SEE NATIONAL PARK SERVICE STATEMENT OF STRUCTURAL TESTS AND SPECIAL INSPECTIONS FOR ADDITIONAL INFORMATION AND REQUIRED FREQUENCY.
2. ITEMS MARKED WITH A "X" INDICATED WHETHER THE INSPECTION IS CONTINUOUS OR PERIODIC AS DEFINED IN IBC SECTION 1702.1.
FOR ITEMS NOT MARKED WITH A "X", COMPLY WITH IBC CHAPTER 17.
3. TESTING AND INSPECTION REPORTS SHALL BE SUBMITTED TO THE CONTRACTING OFFICER, AND CONTRACTOR.
4. SEE STATEMENT OF STRUCTURAL SPECIAL INSPECTIONS AND TEST IN PROJECT SPECIFICATIONS. THE MORE STRICT REQUIREMENT OF THE SPECIFICATIONS OR THIS SPECIAL INSPECTION SCHEDULE SHALL APPLY AND BE CONDUCTED BY THE CONTRACTOR.
INSPECTION SCHEDULE NOTES:
ST
ERE
D PROFESSIONA
L
PAUL N. CROCK
ER
ENGI
NEER
JAN. 14,2003
OREGON
72398PE
STR
UCTURAL
EXPIRES 12/31/21
SHEET
PMIS/PKG NO.
DRAWING NO.
142813
SUB SHEET NO.DESIGNED:
CADD:
TECH REVIEW:
DATE:
TITLE OF SHEET
KAO, HM
RLC
PNC
TVC
SNOW ROOF
CRATER LAKE NATIONAL PARK OF 2211
/1
7/
:2 7:
P
M C
:\M Y
C ra p\ R ev it
Lo ca l F ile s\
\6
N P
S C ra te r La ke T
V C
\2
4_
-0
_C
R
LA
_T V
C _S
T R
U _R
LC
.r vt
S0.4
2020.11.20
CRLA 198641
SPECIAL INSPECTION SCHEDULES
COLD-FORMED STEEL DECKS
GEOTECHNICAL
TESTS
CONCRETE
SEISMIC STEEL INSPECTION TASKSEISMIC BOLTING
SPECIAL INSPECTION OF CONCRETE CONSTRUCTION
AISC 341 CH. J 1705.12.1
PROTECTED ZONE, NO HOLES AND UNAPPROVED ATTACHMENTS MADE
BY BY FABRICATOR OR ERECTOR, AS APPLICABLE
DPDP
- CONTOUR AND FINISH
- DIMENSION TOLERANCES
DPDP
RBS REQUIREMENTS, IF APPLICABLE
DOCTASKDOCTASK
QAQC
OTHER INSPECTION TASKS
b. MECHANICAL ANCHORS AND ADHESIVE ANCHORS NOT DEFINED IN 4a
a. ADHESIVE ANCHORS INSTALLED IN HORIZONTALLY OR
UPWARDLY INCLINED ORIENTATIONS TO RESIST SUSTAINED
TENSION LOADS
c. INSPECT ALL OTHER WELDS
b. INSPECT SINGLE-PASS FILLET WELDS, MAXIMUM 5/16"
a. VERIFY WELDABILITY OF REINFORCING BARS OTHER THAN
ASTM A706
SDI-QA / QC-2011 1705.2.2
SDI-QA / QC-2011 1705.2.2
SDI-QA / QC-2011 1705.2.2
P PDOCUMENT ACCEPTANCE OR REJECTION OF MECHANICAL FASTENERS
VERIFY REPAIR ACTIVITIES
CHECK SPACING, TYPE, AND INSTALLATION OF PERIMETER FASTENERS
CHECK SPACING, TYPE, AND INSTALLATION OF SIDELAP FASTENERS
CHECK SPACING, TYPE, AND INSTALLATION OF SUPPORT FASTENERS
INSPECTION OR EXECUTION TASKS DURING MECHANICAL FASTENING
O OFASTENERS ARE INSTALLED IN ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS
O OFASTENERS ARE POSITIONED AS REQUIRED
INSPECTION OR EXECUTION TASKS DURING MECHANICAL FASTENING
O OPROPER STORAGE FOR MECHANICAL FASTENERS
O OPROPER TOOLS AVAILABLE FOR FASTENER INSTALLATION
O OMANUFACTURER INSTALLATION INSTRUCTIONS AVAILABLE FOR MECHANICAL FASTENERS
INSPECTION OR EXECUTION TASKS PRIOR TO MECHANICAL FASTENING
DOCUMENT ACCEPTANCE OR REJECTION OF WELDS
VERIFY REPAIR ACTIVITIES
WELDS MEET VISUAL ACCEPTANCE CRITERIA
P PVERIFY SIZE AND LOCATION OF WELDS, INCLUDING SUPPORT, SIDELAP, AND PERIMETER WELDS
INSPECTION OR EXECUTION TASKS AFTER WELDING
OWPS FOLLOWED
OENVIRONMENTAL CONDITIONS (WIND SPEED, MOISTURE, TEMPERATURE)
OCONTROL AND HANDLING OF WELDING CONSUMABLES
OUSE OF QUALIFIED WELDERS
INSPECTION OR EXECUTION TASKS DURING WELDING
OCHECK WELDING EQUIPMENT
OMATERIAL IDENTIFICATION (TYPE / GRADE)
OMANUFACTURER CERTIFICATIONS FOR WELDING CONSUMABLES AVAILABLE
OWELDING PROCEDURE SPECIFICATIONS (WPS) AVAILABLE
INSPECTION OR EXECUTION TASKS PRIOR TO WELDING
PDOCUMENT ACCEPTANCE OR REJECTION OF INSTALLATION OF DECK AND DECK ACCESSORIES
N/A VERIFY DECK MATERIALS ARE REPRESENTED BY THE MILL CERTIFICATIONS THAT COMPLY WITH
THE CONSTRUCTION DOCUMENTS
P VERIFY COMPLIANCE OF DECK AND ALL DECK ACCESSORIES INSTALLATION WITH CONSTRUCTION
DOCUMENTS
INSPECTION OR EXECUTION TASKS AFTER DECK PLACEMENT
INSPECTION OR EXECUTION TASKS PRIOR TO DECK PLACEMENT
PDOCUMENT ACCEPTANCE OR REJECTION OF DECK AND DECK ACCESSORIES
SDI-QA / QC-2011 1705.2.2
P
VERIFY COMPLIANCE OF MATERIALS (DECK AND DECK ACCESSORIES) WITH CONSTRUCTION
DOCUMENTS, INCLUDING PROFILES, MATERIAL PROPERTIES, AND BASE METAL THICKNESS
-ACI 318: 17.8.2
1 WHERE…