B08_Att1_26R0002_NIFC_100-ADM_Repairs_Drawings.pdf

PDF 27 MB Posted

Attached to
NIFC 100-ADM Repairs Federal contract opportunity
Solicitation number
140L0626R0002
Issued by
Department of the Interior Bureau of Land Management Idaho Region

About this file

This file is a set of architectural and construction drawings for repairs to the NIFC 100-ADM (National Interagency Fire Center, Building 100, Administrative) facility. The drawings provide detailed specifications and visual representations for the repair work required at this Department of the Interior Bureau of Land Management facility located in the Idaho Region.

The drawings include multiple sheets depicting structural modifications, mechanical and electrical systems, plumbing configurations, and finish details necessary to complete the facility repairs. These technical documents serve as the basis for contractors to understand the scope of work, material specifications, and construction standards required for the NIFC 100-ADM Repairs solicitation (140L0626R0002). The drawings establish the physical requirements and design standards that bidders must follow when preparing their proposals and cost estimates for this repair project.

View the file

Other files for this federal contract opportunity

Show all 22

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

STOPSTOP

BOLLARD

MCP

MCP

Vehicle Mail

DESIGNERS

ALWAYS THINK SAFETY

Project #

Sh ee t T itl e:

Date:

BLM Project #

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

D ra w n by

R ev is io ns

/1

5/

:2

AM

Q

:\L

BY

D Fe de ra l P ro je ct

F ile s\

-A ct ive P ro je ct s\

.0

NI

FC

A dm in A dd n'l

R ep ai rs

\0

Dr aw in gs

\C

AD

\0

7.

8G

-0

_N

IF

C.

dw g

Ap pr ov ed b y:

C he ck ed b y:

D es ig ne d by

Seal:

De sc rip tio n

Da te

Sheet of 67

12/02/2025

070117.028

140L0622D0002

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

NA

TI

O

NA

L

IN

TE

RA

G

EN

CY

F

IR

E

CE

NT

ER

D ev el op m en t A ve

, B oi se , I

D

8)

-5

IS

SU

ED

F

O R

CO

NS

TR

UC

TI

O

N

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

/02 /25

G-001

SJ

BD

A.

R

IC

O

SJ

BD

SJ

BD

C O

VE

R

S H

EE

T

VICINITY MAPREFERENCE MAP

PROJECT LOCATION

LATITUDE: 43.566850

LONGITUDE: -116.212120

100 ADMINISTRATION

3906 S. VISTA, BOISE, ID 83705

3833 DEVELOPMENT AVE, BOISE, ID 83705

NATIONAL INTERAGENCY FIRE CENTER

NIFC 100-ADMINISTRATION REPAIRS FY 2022 GAOA

BOISE, IDAHO

PROJECT

LOCATION

NN

NIFC

CAMPUS

DRAWING INDEX

SHEET

SUB

SHEET TITLE OF SHEET

GENERAL

1 G-001 COVER SHEET

2 G-002 INDEX SHEET

3 GI100 CODE SHEET BASEMENT

4 GI101 CODE SHEET FIRST FLOOR PLAN

5 GI102 CODE SHEET BASEMENT - BID ADDITIVE #1

6 GI103 DETAILS

HAZARDOUS MATERIALS

7 H-101 ABATEMENT PLAN - BASEMENT

8 H-102 ABATEMENT PLAN - FIRST FLOOR

ARCHITECTURAL

9 AD100 BASEMENT DEMOLITION PLAN

10 AD101 FIRST FLOOR DEMOLITION PLAN

11 AD102 BASEMENT DEMO REFLECTED CEILING PLAN

12 AD103 FIRST FLOOR DEMO REFLECTED CEILING PLAN

13 AE001 LEGEND, NOTES, AND WALL TYPES

14 AE100 BASEMENT FLOOR PLAN

15 AE101 FIRST FLOOR PLAN

16 AE103 BASEMENT REFLECTED CEILING PLAN

17 AE104 FIRST FLOOR REFLECTED CEILING PLAN

18 AE504 WINDOW & DOOR DETAILS

19 AE601 DOOR SCHEDULES AND ELEVATIONS

INTERIORS

20 INT-100 BASEMENT FINISH FLOOR PLAN

21 INT-101 FIRST FLOOR FINISH PLAN

22 INT-501 INTERIOR DETAILS

23 INT-601 MATERIALS LIST

FIRE PROTECTION

24 FA001 GENERAL FIRE ALARM SYSTEM INFORMATION

25 FA002 FIRE ALARM SYSTEM DETAILS

26 FAD100 BASEMENT FIRE ALARM DEMOLITION PLAN

27 FAD101 FIRST FLOOR FIRE ALARM DEMOLITION PLAN

28 FA100 BASEMENT FIRE ALARM REMODEL

29 FA101 FIRST FLOOR FIRE ALARM REMODEL PLAN

30 FD100 BASEMENT FIRE PROTECTION DEMOLITION PLAN

31 FD101 FIRST FLOOR FIRE PROTECTION DEMOLITION PLAN

32 FP001 FIRE PROTECTION SITE PLAN, NOTES & LEGEND

33 FP002 FIRE PROTECTION DETAILS

34 FP100 BASEMENT FIRE PROTECTION PLAN

35 FP101 FIRST FLOOR FIRE PROTECTION PLAN

36 FP200 FIRE PROTECTION SECTIONS AND EXISTING RISER DETAIL

MECHANICAL

37 M001 MECHANICAL GENERAL NOTES, ABBREVIATIONS

38 MD100 BASEMENT HVAC DEMOLITION PLAN

39 MD101 FIRST FLOOR HVAC DEMOLITION PLAN

40 MD121 FIRST FLOOR REFRIGERANT DEMOLITION PIPING PLAN

41 M100 BASEMENT MECHANICAL PLAN

42 M101 FIRST FLOOR MECHANICAL PLAN

43 M102 ROOF MECHANICAL PLAN

44 M121 FIRST FLOOR REFRIGERANT PIPING PLAN

45 M122 SECOND FLOOR REFRIGERANT PIPING PLAN

46 M500 HVAC DETAILS

47 M600 MECHANICAL SCHEDULES

48 M604 HVAC CONTROLS DIAGRAMS

49 M606 VRF SCHEMATIC

PLUMBING

50 PD101 FIRST FLOOR DEMOLITION DWV PLAN

51 P101 FIRST FLOOR DWV PLAN

ELECTRICAL

52 E-001 ELECTRICAL LEGENDS

53 ED100 BASEMENT ELECTRICAL DEMOLITION PLAN

54 ED101 FIRST FLOOR ELECTRICAL DEMOLITION PLAN

55 EL100 BASEMENT LIGHTING PLAN

56 EL101 FIRST FLOOR LIGHTING PLAN

57 EP100 BASEMENT POWER PLAN

58 EP101 FIRST FLOOR POWER PLAN

59 EP111 FIRST FLOOR MECHANICAL POWER PLAN

60 EP112 ROOF POWER PLAN

61 ET100 BASEMENT TELECOM PLAN

62 ET101 FIRST FLOOR TELECOM PLAN

63 EY101 FIRST FLOOR SECURITY PLAN

64 E-500 ELECTRICAL DETAILS

65 E-601 ONE-LINE DIAGRAM

66 E-602 PANEL SCHEDULES

67 E-603 LIGHTING SCHEDULES

ALWAYS THINK SAFETY

Project #

Sh ee t T itl e:

Date:

BLM Project #

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

D ra w n by

R ev is io ns

/1

5/

:2

AM

Q

:\L

BY

D Fe de ra l P ro je ct

F ile s\

-A ct ive P ro je ct s\

.0

NI

FC

A dm in A dd n'l

R ep ai rs

\0

Dr aw in gs

\C

AD

\0

7.

8G

-0

_N

IF

C.

dw g

Ap pr ov ed b y:

C he ck ed b y:

D es ig ne d by

Seal:

De sc rip tio n

Da te

Sheet of 67

12/02/2025

070117.028

140L0622D0002

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

NA

TI

O

NA

L

IN

TE

RA

G

EN

CY

F

IR

E

CE

NT

ER

D ev el op m en t A ve

, B oi se , I

D

8)

-5

IS

SU

ED

F

O R

CO

NS

TR

UC

TI

O

N

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

/02 /25

G-002

SJ

BD

A.

R

IC

O

SJ

BD

SJ

BD

SH

EE

T

IN

D

EX

88888 SF= ######

ROOM NAME SPACE AREA

OCCUPANCY TAG:

NUMBER OF OCCUPANTS

OCCUPANT LOAD FACTOR

FIRE EXTINGUISHER CABINET AND

EXTINGUISHER - SEE SPECIFICATIONS

M

UL RATED FIRE DOOR AND FRAME WITH

RATING AS INDICATED

- SEE SHEET AE601

ROOM / AREA NAME

ROOM / AREA NUMBER

EXIT PATH

SURFACE MOUNTED FIRE

EXINGUISHER - SEE SPECIFICATIONS

# CODE PLAN LEGEND

EGRESS LIGHTING (EXIT SIGNS) - SEE

ELECTRICAL DRAWINGS

B / BUSINESS OCCUPANCY

S2 / STORAGE OCCUPANCY

EXIT TAG:

REQUIRED WIDTH

OCCUPANT LOAD

PROVIDED WIDTH

FEC

FE

EXISTING 1 HOUR FIRE BARRIER - SEAL

PERIMETER AND PENETRATIONS PER

DETAILS ON GI103

CODE REVIEW INFORMATION

THIS ANALYSIS BASED ON BASE BID CONSTRUCTION. FOR BID ADDITIVE #1, SEE GI102.

GOVERNING CODES:

2024 INTERNATIONAL BUILDING CODE

2024 INTERNATIONAL EXISTING BUILDING CODE

2024 INTERNATIONAL FIRE CODE

2024 INTERNATIONAL FUEL GAS CODE

2024 INTERNATIONAL MECHANICAL CODE

2024 INTERNATIONAL PLUMBING CODE

2024 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE

2024 INTERNATIONAL ENERGY CONSERVATION CODE

2024 NFPA 101 LIFE SAFETY CODE

ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS

*SHOULD A CONFLICT EXIST BETWEEN BLM ADOPTED CODES AND STATE OR LOCAL

CODES, BLM ADOPTED CODES SHALL PREVAIL

IEBC 2024 ANALYSIS:

CLASSIFICATION OF WORK: LEVEL 2 ALTERATION

603.1 LEVEL 2 ALTERATIONS INCLUDE THE ADDITION OR ELIMINATION OF ANY DOOR OR

WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE

INSTALLATION OF ANY ADDITIONAL EQUIPMENT, AND SHALL APPLY WHERE THE WORK

AREA IS EQUAL TO OR LESS THAN 50 PERCENT OF THE BUILDING AREA.

603.2 LEVEL 2 ALTERATIONS SHALL COMPLY WITH PROVISIONS OF CHAPTER 7 AND 8

701.2 AN EXISTING BUILDING OR PORTION THERE OF SHALL NOT BE ALTERED SUCH

THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION.

703.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE

PROTECTION PROVIDED.

801.4 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND SPACES SHALL

COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.

802.4 THE INTERIOR FINISH AND TRIM OF WALLS AND CEILINGS IN EXITS AND

CORRIDORS IN ANY WORK AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE

INTERNATIONAL BUILDING CODE.

809.1 LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS ARE PERMITTED WITHOUT

REQUIRING THE ENTIRE BUILDING TO COMPLY WITH THE ENERGY REQUIREMENTS OF

THE INTERNATIONAL ENERGY CONSERVATION CODE. ALTERATIONS SHALL CONFORM

TO THE ENERGY REQUIREMENTS OF TEH INTERNATIONAL ENERGY CONSERVATION

CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.

IBC 2024 ANALYSIS

OCCUPANCY CLASSIFICATION: B (BUSINESS), S-2 (STORAGE) PER SECTION 304.1

BUILDING OCCUPANCY HAS NOT BEEN ALTERED FROM EXISTING

FIRE SPRINKLER SYSTEM: PROVIDED

CONSTRUCTION TYPE: IIB PER SECTION 602.2

BUILDING HEIGHT, AREA, AND NUMBER OF STORIES: NOT ALTERED FROM EXISTING

FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601

FOR TYPE IIB, ALL ELEMENTS EXCEPT EXTERIOR WALLS = 0 HOURS

SECTION 602.2 TYPES I AND II

TYPES I AND II CONSTRUCTION ARE THOSES TYPES OF CONSTRUCTION IN WHICH

THE BUILDING ELEMENTS SPECIFIED IN TBALE 601 ARE OF NONCOMBUSTIBLE

MATERIALS, EXCEPT AS PERMITTED IN SECTION 603 AND ELSEWHERE IN THIS CODE.

CHAPTER 7 RATED / PROTECTED ASSEMBLIES NOT ALTERED FROM EXISTING

INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE

803.13

FOR GROUP B, SPRINKLERED (MOST STRINGENT):

EXIT ENCLOSURES AND EXIT PASSAGEWAYS = B

CORRIDORS & STIARWAYS = C

ROOMS AND ENCLOSED SPACES = C

OCCUPANT LOAD FACTOR FROM TABLE 1004.5 ASSIGNED TO EACH ROOM, TOTALS:

BASEMENT AREAS = 92 OCCUPANTS

FIRST FLOOR AREAS = 93 OCCUPANTS

SECOND FLOOR AREAS = 109 OCCUPANTS

TOTAL OCCUPANCY 294 OCCUPANTS

1.

2.

MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3

STAIRWAYS, SPRINKLERED, GROUP B/S = 0.2 INCHES PER OCCUPANT

OTHER EGRESS COMPONENTS, SPRINKLERED, GROUP B = 0.15 INCHES PER

OCCUPANT

SEE CODE PLANS FOR REQUIRED AND PROVIDED EXIT WIDTHS

EGRESS CONVERGANCE FROM SECTION 1005.6

WHERE THE MEANS OF EGRESS FROM STORIES ABOVE AND BELOW CONVERGE AT

AN INTERMEDIATE LEVEL, THE CAPACITY OF THE MEANS OF EGRESS FROM THE

POINT OF CONVERGENCE SHALL BE NOT LESS THAN THE LARGEST MINIMUM WIDTH

OR THE SUM OF THE REQUIRED CAPACITIES FOR THE STAIRWAYS SERVING THE TWO

ADJACENT STORIES, WHICHEVER IS LARGER.

COMMON PATH OF EGRESS TRAVEL PER TABLE 1006.2.1 =

FOR B OCCUPANCY ROOMS = SHALL NOT EXCEED 100 FEET

SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1

FOR B OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 49

FOR S OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 29

EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2

FOR B OCCUPANCY (MOST STRINGENT), WITH SPRINKLER SYSTEM = 300 FEET

CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.2

FOR B, S OCCUPANCY, WITH SPRINKLER SYSTEM = NO RATING IS REQUIRED

MINIMUM CORRIDOR WIDTH PER TABLE 1020.3 = 44 INCHES.

DEAD END CORRIDORS FROM SECTION 1020.5 EXCEPTION 2

FOR B, S OCCUPANCY, SPRINKLERRED = NO MORE THAN 50 FEET

IECC 2024 ASSEMBLY INFORMATION (A001 FOR ASSEMBLY TYPES)

BOISE, IDAHO | ADA COUNTY - ZONE 5B

SEE ELECTRICAL DRAWINGS FOR DAYLIGHT ZONE LIGHTING CONTROLS

PER TABLE C402.1.3. THE BUILDING ENVELOPE WILL MEET OR EXCEED THE BELOW:

MASS - R-11.4ci WALLS BELOW GRADE - R-7.5c.i. (CONTINUOUS INSULATION)

543 SF = 3715

LARGE MEETING

ROOM

62 SF = 1300

STORAGE

004A

339 SF = 3150

HALL

268 SF = 2150

HALL

108 SF = 1150

SOUND

STUDIO

017B

1250 SF = 9150

MEP

159 SF = 2150

UNASSIGNED

42 SF = 1150

UNASSIGNED

37 SF = 1150

UNASSIGNED

165 SF = 2150

UNASSIGNED

125 SF = 1300

STORAGE

003A

230 SF = 2150

WEST STAIR

111 SF = 1150

HALL

65 SF = 1150

LOCKERS &

SHOWER

89 SF = 1150

MEN'S

250 SF = 2150

IT

452 SF = 4150

PRODUCTION

017D

241 SF = 1300

MULTIMEDIA

STORAGE

232 SF = 2150

EAST STAIR

117 SF = 1150

WOMEN'S

25 SF = 1300

JAN

69 SF = 1150

HALL

49 SF = 1150

ELEVATOR

35 SF = 1150

SOUND BOOTH

017C

EXIT ACCESS TRAVEL DISTANCE

77' - 8"

EXIT SEPARATION

112' - 10"

FEC FEC

6.6"

60"

4.95"

36"

4.8"

36"626.

4"

STORAGE

HALL

81 SF = 1150

CONTROL

DIAGONAL DISTANCE140' - 2"

FE

FINISH FLOOR

4'

- 6

TO

H

AN

DL

E 4'

- 0

MA

X

SEMI-RECESSED FIRE

EXTINGUISHER

CABINET

PORTABLE

FIRE

EXTINGUISHER

C4 EXTINGUISHER MOUNTING HEIGHTS

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:3

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

C O

D E

SH

EE

T

BA

SE

M

EN

T

M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

GI100

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

3 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

B1 BASEMENT CODE PLAN

0 4' 8' 16'

MINIMUM NUMBER OF PLUMBING FIXTURES PER IBC TABLE 2902.1

BASED ON BUSINESS OCCUPANCY (MOST STRINGENT)

294 OCCUPANTS = 147 MALE, 147 FEMALE

THIS ANALYSIS BASED ON BASE BID CONSTRUCTION. FOR BID ADDITIVE, SEE

GI102.

2901.1.2

THE TOTAL NUMBER OF FIXTURES SHALL BE PERMITTED TO BE BASED ON THE

REQUIRED NUMBER OF SEPARATE FACILITIES OR BASED ON THE AGGREGATE

OF ANY COMBINATION OF SINGLE-USER OR SEPARATE FACILITIES

WATER CLOSETS:

1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50

PER IPC 424.2, URINAL SHALL NOT BE SUBSTITUTED FOR MORE THAN 50

PERCENT OF REQUIRED WATER CLOSETS

REQUIRED: 4 MALE,4 FEMALE

PROVIDED: 4 MALE, 3 FEMALE, 4 UNISEX

LAVATORIES:

1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80

FOR BOTH MALE AND FEMALES

REQUIRED: 3 MALE, 3 FEMALE

PROVIDED: 2 MALE, 2 FEMALE, 4 UNISEX

DRINKING FOUNTAINS:

1 PER 100

REQUIRED: 3 TOTAL

PROVIDED: 5

SERVICE SINK:

REQUIRED: 1 TOTAL

PROVIDED: 3

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

.02

.25

N

DN

R

EF

88888 SF= ######

ROOM NAME SPACE AREA

OCCUPANCY TAG:

NUMBER OF OCCUPANTS

OCCUPANT LOAD FACTOR

FIRE EXTINGUISHER CABINET AND

EXTINGUISHER - SEE SPECIFICATIONS

M

UL RATED FIRE DOOR AND FRAME WITH

RATING AS INDICATED

- SEE SHEET AE601

ROOM / AREA NAME

ROOM / AREA NUMBER

EXIT PATH

SURFACE MOUNTED FIRE

EXINGUISHER - SEE SPECIFICATIONS

# CODE PLAN LEGEND

EGRESS LIGHTING (EXIT SIGNS) - SEE

ELECTRICAL DRAWINGS

B / BUSINESS OCCUPANCY

S2 / STORAGE OCCUPANCY

EXIT TAG:

REQUIRED WIDTH

OCCUPANT LOAD

PROVIDED WIDTH

FEC

FE

EXISTING 1 HOUR FIRE BARRIER - SEAL

PERIMETER AND PENETRATIONS PER

DETAILS ON GI103

CODE REVIEW INFORMATION

THIS ANALYSIS BASED ON BASE BID CONSTRUCTION. FOR BID ADDITIVE #1, SEE GI102.

GOVERNING CODES:

2024 INTERNATIONAL BUILDING CODE

2024 INTERNATIONAL EXISTING BUILDING CODE

2024 INTERNATIONAL FIRE CODE

2024 INTERNATIONAL FUEL GAS CODE

2024 INTERNATIONAL MECHANICAL CODE

2024 INTERNATIONAL PLUMBING CODE

2024 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE

2024 INTERNATIONAL ENERGY CONSERVATION CODE

2024 NFPA 101 LIFE SAFETY CODE

ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS

*SHOULD A CONFLICT EXIST BETWEEN BLM ADOPTED CODES AND STATE OR LOCAL

CODES, BLM ADOPTED CODES SHALL PREVAIL

IEBC 2024 ANALYSIS:

CLASSIFICATION OF WORK: LEVEL 2 ALTERATION

603.1 LEVEL 2 ALTERATIONS INCLUDE THE ADDITION OR ELIMINATION OF ANY DOOR OR

WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE

INSTALLATION OF ANY ADDITIONAL EQUIPMENT, AND SHALL APPLY WHERE THE WORK

AREA IS EQUAL TO OR LESS THAN 50 PERCENT OF THE BUILDING AREA.

603.2 LEVEL 2 ALTERATIONS SHALL COMPLY WITH PROVISIONS OF CHAPTER 7 AND 8

701.2 AN EXISTING BUILDING OR PORTION THERE OF SHALL NOT BE ALTERED SUCH

THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION.

703.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE

PROTECTION PROVIDED.

801.4 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND SPACES SHALL

COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.

802.4 THE INTERIOR FINISH AND TRIM OF WALLS AND CEILINGS IN EXITS AND

CORRIDORS IN ANY WORK AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE

INTERNATIONAL BUILDING CODE.

809.1 LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS ARE PERMITTED WITHOUT

REQUIRING THE ENTIRE BUILDING TO COMPLY WITH THE ENERGY REQUIREMENTS OF

THE INTERNATIONAL ENERGY CONSERVATION CODE. ALTERATIONS SHALL CONFORM

TO THE ENERGY REQUIREMENTS OF TEH INTERNATIONAL ENERGY CONSERVATION

CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.

IBC 2024 ANALYSIS

OCCUPANCY CLASSIFICATION: B (BUSINESS), S-2 (STORAGE) PER SECTION 304.1

BUILDING OCCUPANCY HAS NOT BEEN ALTERED FROM EXISTING

FIRE SPRINKLER SYSTEM: PROVIDED

CONSTRUCTION TYPE: IIB PER SECTION 602.2

BUILDING HEIGHT, AREA, AND NUMBER OF STORIES: NOT ALTERED FROM EXISTING

FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601

FOR TYPE IIB, ALL ELEMENTS EXCEPT EXTERIOR WALLS = 0 HOURS

SECTION 602.2 TYPES I AND II

TYPES I AND II CONSTRUCTION ARE THOSES TYPES OF CONSTRUCTION IN WHICH

THE BUILDING ELEMENTS SPECIFIED IN TBALE 601 ARE OF NONCOMBUSTIBLE

MATERIALS, EXCEPT AS PERMITTED IN SECTION 603 AND ELSEWHERE IN THIS CODE.

CHAPTER 7 RATED / PROTECTED ASSEMBLIES NOT ALTERED FROM EXISTING

INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE

803.13

FOR GROUP B, SPRINKLERED (MOST STRINGENT):

EXIT ENCLOSURES AND EXIT PASSAGEWAYS = B

CORRIDORS & STIARWAYS = C

ROOMS AND ENCLOSED SPACES = C

OCCUPANT LOAD FACTOR FROM TABLE 1004.5 ASSIGNED TO EACH ROOM, TOTALS:

BASEMENT AREAS = 92 OCCUPANTS

FIRST FLOOR AREAS = 93 OCCUPANTS

SECOND FLOOR AREAS = 109 OCCUPANTS

TOTAL OCCUPANCY 294 OCCUPANTS

1.

2.

MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3

STAIRWAYS, SPRINKLERED, GROUP B/S = 0.2 INCHES PER OCCUPANT

OTHER EGRESS COMPONENTS, SPRINKLERED, GROUP B = 0.15 INCHES PER

OCCUPANT

SEE CODE PLANS FOR REQUIRED AND PROVIDED EXIT WIDTHS

EGRESS CONVERGANCE FROM SECTION 1005.6

WHERE THE MEANS OF EGRESS FROM STORIES ABOVE AND BELOW CONVERGE AT

AN INTERMEDIATE LEVEL, THE CAPACITY OF THE MEANS OF EGRESS FROM THE

POINT OF CONVERGENCE SHALL BE NOT LESS THAN THE LARGEST MINIMUM WIDTH

OR THE SUM OF THE REQUIRED CAPACITIES FOR THE STAIRWAYS SERVING THE TWO

ADJACENT STORIES, WHICHEVER IS LARGER.

COMMON PATH OF EGRESS TRAVEL PER TABLE 1006.2.1 =

FOR B OCCUPANCY ROOMS = SHALL NOT EXCEED 100 FEET

SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1

FOR B OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 49

FOR S OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 29

EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2

FOR B OCCUPANCY (MOST STRINGENT), WITH SPRINKLER SYSTEM = 300 FEET

CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.2

FOR B, S OCCUPANCY, WITH SPRINKLER SYSTEM = NO RATING IS REQUIRED

MINIMUM CORRIDOR WIDTH PER TABLE 1020.3 = 44 INCHES.

DEAD END CORRIDORS FROM SECTION 1020.5 EXCEPTION 2

FOR B, S OCCUPANCY, SPRINKLERRED = NO MORE THAN 50 FEET

IECC 2024 ASSEMBLY INFORMATION (A001 FOR ASSEMBLY TYPES)

BOISE, IDAHO | ADA COUNTY - ZONE 5B

SEE ELECTRICAL DRAWINGS FOR DAYLIGHT ZONE LIGHTING CONTROLS

PER TABLE C402.1.3. THE BUILDING ENVELOPE WILL MEET OR EXCEED THE BELOW:

MASS - R-11.4ci WALLS BELOW GRADE - R-7.5c.i. (CONTINUOUS INSULATION)

5'

1/

2"

11' - 2 3/4"

1402 SF = 10150

OPEN OFFICE

257 SF = 2150

HALL

532 SF = 4150

OPEN OFFICE

103 SF = 1150

OFFICE

134B

103 SF = 1150

OFFICE

134A

63 SF = 1150

FOCUS

82 SF = 1300

IDF

134 SF = 1150

OFFICE

107 SF = 1150

OFFICE

101 SF = 1150

OFFICE

100 SF = 1150

OFFICE

99 SF = 1150

OFFICE

122 SF = 1150

VESTIBULE

194 SF = 2150

LOBBY

209 SF = 2150

HALL

93 SF = 1150

OFFICE

104 SF = 1150

OFFICE

94 SF = 1150

OFFICE

359 SF = 3150

HALL

133 SF = 1150

OFFICE

281 SF = 1915

LEO-CONF

96 SF = 1150

RESTROOM

291 SF = 2015

BREAK ROOM

72 SF = 1150

WELLNESS

54 SF = 1300

STORAGE

49 SF = 1150

ELEVATOR

232 SF = 2150

EAST STAIR

152 SF = 1300

HD FILES

95 SF = 1300

DUCT-

CHASE

42 SF = 1300

STORAGE

58 SF = 1300

JANITOR

58 SF = 1300

UTILITY

230 SF = 2150

WEST STAIR

126 SF = 1150

HALL

141 SF = 1150

MEN'S

160 SF = 2150

WOMEN'S

146 SF = 1150

HALL

EX

IT

T R

AV

EL

D

IS

T.

EXIT TRAVEL DIST.

74' - 5"

EX

IT

T R

AV

EL

D

IS

T.

1"

FECFEC

13.05"

36"

4.2"

36"

4.35"

72"

4.2"

36"

13.05"

36"

154.

DIAGONAL DISTANCE140' - 2"

EXIT SEPARATION

112' - 10"

55 62 63 54

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:4

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

C O

D E

SH

EE

T

FI

R

ST

F

LO

O R

PL

AN

M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

GI101

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

4 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

B1 FIRST FLOOR CODE PLAN

NOTE: SEE OTHER CODE PLAN SHEETS FOR ADDITIONAL CODE REVIEW

INFORMATION

NFPA 101 2024 CODE ANALYSIS

OCCUPANCY: BUSINESS

STORIES: 3

CONSTRUCTION TYPE: II-000 SPRINKLERED

PER NFPA 220 TABLE 4.1.1 -

TYPE II-000 - BUILDING ELEMENTS REQUIRE NO RATING.

PER 39.1.1.1 - CLASSIFICATION OF HAZARD CONTENTS - ORDINARY

PER 39.2.2 - ARRANGEMENTS OF MEANS OF EGRESS IS AS FOLLOWS:

9.2.5.1 - DEAD-END CORRIDOR = 50' MAXIMUM

9.2.5.3.1 - COMMON PATH OF TRAVEL = 100' MAXIMUM

PER 39.2.6.3 - MAXIMUM TRAVEL DISTANCE TO EXITS = 300'

PER 39.3.6 - CORRIDORS - TO HAVE A MIN. 0-HOUR FIRE RESISTANCE RATING

PER TABLE 7.1.3.1 - EXIT ACCESS CORRIDORS TO BE 0 HOURS

FIRE PARTITIONS - DOORS IN THESE CORRIDORS TO HAVE A RATING OF 20 MIN.

ABA CODE ANALYSIS

F202.3 ALTERATIONS

WHERE EXISTING ELEMENTS OR SPACES ARE ALTERED, EACH ALTERED ELEMENT OR SPACE

SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF CHAPTER 2.

F202.4 ALTERATIONS AFFECTING PRIMARY FUNCTION AREAS

PRIMARY FUNCTION AREAS ARE ALL LOCATED ON ACCESSIBLE ROUTES. RESTROOMS ON EACH

FLOOR WILL BE MADE ACCESSIBLE TO OCCUPANTS AND WILL BE INCLUDED ON ACCESSIBLE

ROUTES.

0 4' 8' 16'

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

.02

88888 SF= ######

ROOM NAME SPACE AREA

OCCUPANCY TAG:

NUMBER OF OCCUPANTS

OCCUPANT LOAD FACTOR

FIRE EXTINGUISHER CABINET AND

EXTINGUISHER - SEE SPECIFICATIONS

M

UL RATED FIRE DOOR AND FRAME WITH

RATING AS INDICATED

- SEE SHEET AE601

ROOM / AREA NAME

ROOM / AREA NUMBER

EXIT PATH

SURFACE MOUNTED FIRE

EXINGUISHER - SEE SPECIFICATIONS

# CODE PLAN LEGEND

EGRESS LIGHTING (EXIT SIGNS) - SEE

ELECTRICAL DRAWINGS

B / BUSINESS OCCUPANCY

S2 / STORAGE OCCUPANCY

EXIT TAG:

REQUIRED WIDTH

OCCUPANT LOAD

PROVIDED WIDTH

FEC

FE

EXISTING 1 HOUR FIRE BARRIER - SEAL

PERIMETER AND PENETRATIONS PER

DETAILS ON GI103

543 SF = 3715

LARGE MEETING

ROOM

62 SF = 1300

STORAGE

004A

173 SF = 1215

MEETING ROOM

340 SF = 2315

LARGE MEETING

ROOM

197 SF = 1415

MEETING ROOM

414 SF = 2815

LARGE MEETING

ROOM

183 SF = 1300

STORAGE

339 SF = 3150

HALL

268 SF = 2150

HALL

108 SF = 1150

SOUND

STUDIO

017B

1250 SF = 9150

MEP

159 SF = 2150

UNASSIGNED

42 SF = 1150

UNASSIGNED

37 SF = 1150

UNASSIGNED

165 SF = 2150

UNASSIGNED

125 SF = 1300

STORAGE

003A

230 SF = 2150

WEST STAIR

111 SF = 1150

HALL

65 SF = 1150

LOCKERS &

SHOWER

89 SF = 1150

MEN'S

250 SF = 2150

IT

452 SF = 4150

PRODUCTION

017D

241 SF = 1300

MULTIMEDIA

STORAGE

232 SF = 2150

EAST STAIR

117 SF = 1150

WOMEN'S

25 SF = 1300

JAN

69 SF = 1150

HALL

49 SF = 1150

ELEVATOR

35 SF = 1150

SOUND BOOTH

017C

EXIT ACCESS TRAVEL DISTANCE

77' - 8"

EXIT SEPARATION

112' - 10"

FEC FEC

6.6"

60"

4.95"

36"

4.8"

36"816.

4"

81 SF = 1150

CONTROL

DIAGONAL DISTANCE140' - 2"

FE

CODE REVIEW INFORMATION

THIS ANALYSIS BASED ON BID ADDITIVE #1 CONSTRUCTION.

GOVERNING CODES:

2024 INTERNATIONAL BUILDING CODE

2024 INTERNATIONAL EXISTING BUILDING CODE

2024 INTERNATIONAL FIRE CODE

2024 INTERNATIONAL FUEL GAS CODE

2024 INTERNATIONAL MECHANICAL CODE

2024 INTERNATIONAL PLUMBING CODE

2024 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE

2024 INTERNATIONAL ENERGY CONSERVATION CODE

2024 NFPA 101 LIFE SAFETY CODE

ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS

*SHOULD A CONFLICT EXIST BETWEEN BLM ADOPTED CODES AND STATE OR LOCAL

CODES, BLM ADOPTED CODES SHALL PREVAIL

IEBC 2024 ANALYSIS:

CLASSIFICATION OF WORK: LEVEL 2 ALTERATION

603.1 LEVEL 2 ALTERATIONS INCLUDE THE ADDITION OR ELIMINATION OF ANY DOOR OR

WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE

INSTALLATION OF ANY ADDITIONAL EQUIPMENT, AND SHALL APPLY WHERE THE WORK

AREA IS EQUAL TO OR LESS THAN 50 PERCENT OF THE BUILDING AREA.

603.2 LEVEL 2 ALTERATIONS SHALL COMPLY WITH PROVISIONS OF CHAPTER 7 AND 8

701.2 AN EXISTING BUILDING OR PORTION THERE OF SHALL NOT BE ALTERED SUCH

THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION.

703.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE

PROTECTION PROVIDED.

801.4 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND SPACES SHALL

COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.

802.4 THE INTERIOR FINISH AND TRIM OF WALLS AND CEILINGS IN EXITS AND

CORRIDORS IN ANY WORK AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE

INTERNATIONAL BUILDING CODE.

809.1 LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS ARE PERMITTED WITHOUT

REQUIRING THE ENTIRE BUILDING TO COMPLY WITH THE ENERGY REQUIREMENTS OF

THE INTERNATIONAL ENERGY CONSERVATION CODE. ALTERATIONS SHALL CONFORM

TO THE ENERGY REQUIREMENTS OF TEH INTERNATIONAL ENERGY CONSERVATION

CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.

IBC 2024 ANALYSIS

OCCUPANCY CLASSIFICATION: B (BUSINESS), S-2 (STORAGE) PER SECTION 304.1

BUILDING OCCUPANCY HAS NOT BEEN ALTERED FROM EXISTING

FIRE SPRINKLER SYSTEM: PROVIDED

CONSTRUCTION TYPE: IIB PER SECTION 602.2

BUILDING HEIGHT, AREA, AND NUMBER OF STORIES: NOT ALTERED FROM EXISTING

FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601

FOR TYPE IIB, ALL ELEMENTS EXCEPT EXTERIOR WALLS = 0 HOURS

SECTION 602.2 TYPES I AND II

TYPES I AND II CONSTRUCTION ARE THOSES TYPES OF CONSTRUCTION IN WHICH

THE BUILDING ELEMENTS SPECIFIED IN TBALE 601 ARE OF NONCOMBUSTIBLE

MATERIALS, EXCEPT AS PERMITTED IN SECTION 603 AND ELSEWHERE IN THIS CODE.

CHAPTER 7 RATED / PROTECTED ASSEMBLIES NOT ALTERED FROM EXISTING

INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE

803.13

FOR GROUP B, SPRINKLERED (MOST STRINGENT):

EXIT ENCLOSURES AND EXIT PASSAGEWAYS = B

CORRIDORS & STIARWAYS = C

ROOMS AND ENCLOSED SPACES = C

OCCUPANT LOAD FACTOR FROM TABLE 1004.5 ASSIGNED TO EACH ROOM, TOTALS:

BASEMENT AREAS = 162 OCCUPANTS

FIRST FLOOR AREAS = 93 OCCUPANTS

SECOND FLOOR AREAS = 109 OCCUPANTS

TOTAL OCCUPANCY 364 OCCUPANTS

1.

2.

MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3

STAIRWAYS, SPRINKLERED, GROUP B/S = 0.2 INCHES PER OCCUPANT

OTHER EGRESS COMPONENTS, SPRINKLERED, GROUP B = 0.15 INCHES PER

OCCUPANT

SEE CODE PLANS FOR REQUIRED AND PROVIDED EXIT WIDTHS

EGRESS CONVERGANCE FROM SECTION 1005.6

WHERE THE MEANS OF EGRESS FROM STORIES ABOVE AND BELOW CONVERGE AT

AN INTERMEDIATE LEVEL, THE CAPACITY OF THE MEANS OF EGRESS FROM THE

POINT OF CONVERGENCE SHALL BE NOT LESS THAN THE LARGEST MINIMUM WIDTH

OR THE SUM OF THE REQUIRED CAPACITIES FOR THE STAIRWAYS SERVING THE TWO

ADJACENT STORIES, WHICHEVER IS LARGER.

COMMON PATH OF EGRESS TRAVEL PER TABLE 1006.2.1 =

FOR B OCCUPANCY ROOMS = SHALL NOT EXCEED 100 FEET

SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1

FOR B OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 49

FOR S OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 29

EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2

FOR B OCCUPANCY (MOST STRINGENT), WITH SPRINKLER SYSTEM = 300 FEET

CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.2

FOR B, S OCCUPANCY, WITH SPRINKLER SYSTEM = NO RATING IS REQUIRED

MINIMUM CORRIDOR WIDTH PER TABLE 1020.3 = 44 INCHES.

DEAD END CORRIDORS FROM SECTION 1020.5 EXCEPTION 2

FOR B, S OCCUPANCY, SPRINKLERRED = NO MORE THAN 50 FEET

IECC 2024 ASSEMBLY INFORMATION (A001 FOR ASSEMBLY TYPES)

BOISE, IDAHO | ADA COUNTY - ZONE 5B

SEE ELECTRICAL DRAWINGS FOR DAYLIGHT ZONE LIGHTING CONTROLS

PER TABLE C402.1.3. THE BUILDING ENVELOPE WILL MEET OR EXCEED THE BELOW:

MASS - R-11.4ci WALLS BELOW GRADE - R-7.5c.i. (CONTINUOUS INSULATION)

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:4

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

C O

D E

SH

EE

T

BA

SE

M

EN

T

BI

D A

D D

IT

IV

E #1

M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

GI102

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

5 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

B1 BASEMENT CODE PLAN - BID ADDITIVE #1

MINIMUM NUMBER OF PLUMBING FIXTURES PER IBC TABLE 2902.1

BASED ON BUSINESS OCCUPANCY (MOST STRINGENT)

364 OCCUPANTS = 182 MALE, 182 FEMALE

THIS ANALYSIS BASED ON BID ADDITIVE #1 CONSTRUCTION

2901.1.2

THE TOTAL NUMBER OF FIXTURES SHALL BE PERMITTED TO BE BASED ON THE

REQUIRED NUMBER OF SEPARATE FACILITIES OR BASED ON THE AGGREGATE

OF ANY COMBINATION OF SINGLE-USER OR SEPARATE FACILITIES

WATER CLOSETS:

1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50

PER IPC 424.2, URINAL SHALL NOT BE SUBSTITUTED FOR MORE THAN 50

PERCENT OF REQUIRED WATER CLOSETS

REQUIRED: 5 MALE,5 FEMALE

PROVIDED: 4 MALE, 3 FEMALE, 4 UNISEX

LAVATORIES:

1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80

FOR BOTH MALE AND FEMALES

REQUIRED: 4 MALE, 4 FEMALE

PROVIDED: 2 MALE, 2 FEMALE, 4 UNISEX

DRINKING FOUNTAINS:

1 PER 100

REQUIRED: 4 TOTAL

PROVIDED: 5

SERVICE SINK:

REQUIRED: 1 TOTAL

PROVIDED: 3

0 4' 8' 16'

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

.02

SYSTEM NO. C-AJ-3069

F RATING - 1 HR

T RATING - 1/2 HR

A

A

1A

1.

A.

2.

A.

3.

4.

FLOOR OR WALL ASSEMBLY

CONCRETE OR CMU

THROUGH PENETRANTS

CABLES

PACKING MATERIAL

FIRESTOP SEALANT

SECTION A-A

5/8 MIN

SYSTEM NO. WL 3065

F RATING - 1 HR & 2 HR (SEE ITEM 1)

T RATING - 0 HR & 3/4 HR (SEE ITEM 2)

L RATING AT AMBIENT - 15 CFM/SQ FT

L RATING AT 400 F - 8 CFM/SQ FT

A

A

1C

1A 1B

1. WALL ASSEMBLY

A. STUDS

B. BATTS AND BLANKETS

C. GYPSUM BOARD

2. THROUGH PENETRANTS

A. CABLES

3. METALLIC SLEEVE (OPTIONAL)

4. FIRESTOP SEALANT

SECTION A-A

ONE

HOUR

TWO

HOUR

1/2"

BEAD

5/

M

IN

SYSTEM NO. WL 5029

F RATING - 1, 2 & 3 HR (SEE ITEMS 1, 3 & 4)

T RATING - 0, 1/2, 1 & 1-1/4 HR. (SEE ITEM 3)

L RATING AT AMBIENT - 4CFM/SQ FT

L RATING AT 400 F - LESS THAN 1 CFM/SQ FT

A

A

1B

1A

SECTION A-A

1. WALL ASSEMBLY

A. STUDS

B. (2)GYPSUM BOARD

2. THROUGH PENETRANTS

A. STEEL PIPE

B. CONDUIT

C. COPPER TUBING

3. PIPE COVERING

4. FILL WITH FIRESTOP SEALANT

ONE

HOUR

TWO

HOUR

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:4

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

D

ET

AI

LS M

O R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

GI103

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

6 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

D1 CABLE BUNDLE THROUGH CMU WALL ASSEMBLY D2 CABLE BUNDLE THROUGH GYP WALL ASSEMBLY D4

INSULATED METALLIC PIPE WALL PENETRATION FIRE

STOP

SCALE IN FEET

SCALE IN FEET

SCALE IN FEET

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

.02

0.19 12345678

D

C

B

A

B.1

C.1

C.2

STORAGE

004A

STORAGE

SOUND

STUDIO

017B

MEP

STORAGE

003A

UNASSIGNED

UNASSIGNED

WEST STAIR

EAST STAIR

HALL

HALL

JAN

WOMEN'S

MEN'S

LOCKERS &

SHOWER

HALL

IT

PRODUCTION

017D

HALL

HALL

SOUND BOOTH

017C MULTIMEDIA

STORAGE

UNASSIGNED

UNASSIGNED

OFFICE

OFFICE

CONFERENCE

OFFICE

OFFICE

CONFERENCE

TELECOM

BID ADDITIVE #1

ALWAYS THINK SAFETY

Project #

Sh ee t T itl e:

Date:

BLM Project #

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

D ra w n by

R ev is io ns

/1

5/

:2

AM

Q

:\L

BY

D Fe de ra l P ro je ct

F ile s\

-A ct ive P ro je ct s\

.0

NI

FC

A dm in A dd n'l

R ep ai rs

\0

Dr aw in gs

\C

AD

\0

7.

8H

-1

.d wg

A

B

C

D

2 3 4 5

Ap pr ov ed b y:

C he ck ed b y:

D es ig ne d by

Seal:

De sc rip tio n

Da te

Sheet of 67

12/02/2025

070117.028

140L0622D0002

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

NA

TI

O

NA

L

IN

TE

RA

G

EN

CY

F

IR

E

CE

NT

ER

D ev el op m en t A ve

, B oi se , I

D

8)

-5

IS

SU

ED

F

O R

CO

NS

TR

UC

TI

O

N

070117.028Project No.

LBYD FEDERAL, LLC

1425 Higham Street Idaho Falls, Idaho 83402 Phone (208) 528-8718

C copyright 2022 These drawings and design intent are the sole property of LBYD FEDERAL, LLC which may not be reproduced without written permission.

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

/02 /25

0 8'4' 16'

BASEMENT ABATEMENT PLANB2

H-101

S.

B

AL

LO

CK

-D

IX

ON

A.

R

IC

O

G . T

H O

R

SO

N

S.

B

AL

LO

CK

-D

IX

ON

AB

AT

EM

EN

T

PL

AN

BA

SE

M

EN

T

GENERAL SHEET NOTES

1. BUILDING REQUIRES ASBESTOS ABATEMENT.

2. REMOVE AND DISPOSE IDENTIFIED MATERIALS PER

SPECIFICATION 28214.

3. INFORMATION IS BASED ON ACM EVALUATION TEST

RESULTS DATED 11/29/18 AND 11/12/18.

4. MATERIALS TO BE REMOVED ARE SHOWN IN THE

DEMOLITION PLANS PROVIDED FOR ARCHITECTURE,

PLUMBING, CIVIL, STRUCTURAL, MECHANICAL AND FIRE

PROTECTION MODIFICATIONS.

5. CONTRACTOR TO REVIEW ALL DEMOLITION AREAS AND

DETERMINE IF MATERIAL CONTAIN SIMILAR ASBESTOS

IDENTIFIED MATERIALS. NOTE 7 IDENTIFIES KNOWN ACM

MATERIALS IN BUILDING. ADDITIONAL ACM MAY BE

PRESENT IN ALL DEMOLITION AREAS AND SHOULD BE

CONFIRMED BY CONTRACTOR.

6. CONTRACTOR IS REQUIRED TO DEVELOP PROJECT

SPECIFIC ABATEMENT PLAN PRIOR TO THE START OF ANY

DEMOLITION ACTIVITIES.

7. OTHER ACM CONTAINING MATERIALS HAVE BEEN

IDENTIFIED. THESE ITEMS INCLUDE:

A. BEIGE TILE W/BLACK MASTIC & YELLOW MASTIC

· 3% CHRYSOTILE IN TILE

· 5% CHRYSOTILE IN MASTIC

B. WHITE TILE W/BLACK MASTIC & TAN MASTIC

· 3% CHRYSOTILE IN TILE

· 5% CHRYSOTILE IN MASTIC

C. WHITE TILE W/BLACK & YELLOW MASTIC

· 3% CHRYSOTILE IN TILE

· 5% CHRYSOTILE IN MASTIC

GENERAL DEMOLITION AREA TO BE ABATED

LEGENDN

ABATE IF TILES FOUND UNDER CARPET

EF

0.19 12345678

D

C

B

A

B.1

C.1

C.2

FOCUS

IDF

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

LOBBY

HALL

110OFFICE

OFFICE

OFFICE

WEST STAIR

HALL

OFFICE

122 LEO-CONF

RESTROOM

BREAK ROOM

WELLNESS

STORAGE

WOMEN'S

MEN'S

HALL

UTILITY

JANITOR

HD FILES

DUCT-

CHASE

STORAGE

EAST STAIR

ELEVATOR

HALL

WORK/MAIL 131

MEDIUM

CONFERENCE

HUDDLE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

ALWAYS THINK SAFETY

Project #

Sh ee t T itl e:

Date:

BLM Project #

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

D ra w n by

R ev is io ns

/1

5/

:2

AM

Q

:\L

BY

D Fe de ra l P ro je ct

F ile s\

-A ct ive P ro je ct s\

.0

NI

FC

A dm in A dd n'l

R ep ai rs

\0

Dr aw in gs

\C

AD

\0

7.

8H

-1

.d wg

A

B

C

D

2 3 4 5

Ap pr ov ed b y:

C he ck ed b y:

D es ig ne d by

Seal:

De sc rip tio n

Da te

Sheet of 67

12/02/2025

070117.028

140L0622D0002

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

NA

TI

O

NA

L

IN

TE

RA

G

EN

CY

F

IR

E

CE

NT

ER

D ev el op m en t A ve

, B oi se , I

D

8)

-5

IS

SU

ED

F

O R

CO

NS

TR

UC

TI

O

N

070117.028Project No.

LBYD FEDERAL, LLC

1425 Higham Street Idaho Falls, Idaho 83402 Phone (208) 528-8718

C copyright 2022 These drawings and design intent are the sole property of LBYD FEDERAL, LLC which may not be reproduced without written permission.

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

/02 /25

0 8'4' 16'

FIRST FLOOR ABATEMENT PLANB2

H-102

S.

B

AL

LO

CK

-D

IX

ON

A.

R

IC

O

G . T

H O

R

SO

N

S.

B

AL

LO

CK

-D

IX

ON

AB

AT

EM

EN

T

PL

AN

FI

R

ST

F

LO

O

R

GENERAL SHEET NOTES

1. BUILDING REQUIRES ASBESTOS ABATEMENT.

2. REMOVE AND DISPOSE IDENTIFIED MATERIALS PER

SPECIFICATION 28214.

3. INFORMATION IS BASED ON ACM EVALUATION TEST

RESULTS DATED 11/29/18 AND 11/12/18.

4. MATERIALS TO BE REMOVED ARE SHOWN IN THE

DEMOLITION PLANS PROVIDED FOR ARCHITECTURE,

PLUMBING, CIVIL, STRUCTURAL, MECHANICAL AND FIRE

PROTECTION MODIFICATIONS.

5. CONTRACTOR IS REQUIRED TO DEVELOP PROJECT

SPECIFIC ABATEMENT PLAN PRIOR TO THE START OF ANY

DEMOLITION ACTIVITIES. NOTE 7 IDENTIFIES KNOWN ACM

MATERIALS IN BUILDING. ADDITIONAL ACM MAY BE

PRESENT IN ALL DEMOLITION AREAS AND SHOULD BE

CONFIRMED BY CONTRACTOR.

6. IN GENERAL, ALL DRYWALL MUD HAS BEEN IDENTIFIED AS

HAVING ~3% CHRYSOTILE MATERIAL.

7. OTHER ACM CONTAINING MATERIALS HAVE BEEN

IDENTIFIED. THESE ITEMS INCLUDE:

A. BEIGE TILE W/BLACK MASTIC & YELLOW MASTIC

· 3% CHRYSOTILE IN TILE

· 5% CHRYSOTILE IN MASTIC

B. WHITE TILE W/BLACK MASTIC & TAN MASTIC

· 3% CHRYSOTILE IN TILE

· 5% CHRYSOTILE IN MASTIC

C. WHITE TILE W/BLACK & YELLOW MASTIC

· 3% CHRYSOTILE IN TILE

· 5% CHRYSOTILE IN MASTIC

8. CONTRACTOR SHALL REMOVE AND PROPERLY DISPOSE

EXISTING ROOF SYSTEMS AND FLASHING SYSTEMS

DOWN TO METAL ROOF AND PERIMETER SUBSTRATES AS

ASSOCIATED WITH THE DEMOLITION OF THE CUPOLA

ROOFTOP. 47% CHRYSOTILE ASBESTOS HAS BEEN

FOUND IN THE ROOF FELTS. REMOVAL OF MATERIALS

SHALL BE DONE IN ACCORDANCE WITH THE ABATEMENT

SPECIFICATION AND AS IDENTIFIED ON DRAWING A004.

LEGEND

GENERAL DEMOLITION AREA TO BE ABATED

N

ABATE ALL DRYWALL AND

JOINT COMPOUND

GENERAL SIDE OF WALL TO BE ABATED

ABATE INSIDE OF WALL IN

DEMOLITION AREA ONLY

DO NOT ABATE

CMU WALLS

ABATE ALL INTERNAL WALLS

WITHIN DEMOLITION AREA

ABATE BOTH

SIDES OF WALL

ABATE BOTH

SIDES OF WALL

BOTH SIDES OF NEW WALL DOES

NOT REQUIRE ABATEMENT

D

C

B

A

B.1

C.1

C.2

BID ADDITIVE #1

STORAGE

004A

STORAGE

SOUND

STUDIO

017B

66666666

MEP

STORAGE

003A

UNASSIGNED

UNASSIGNED

WEST STAIR

EAST STAIR

HALL

HALL

JAN

WOMEN'S

MEN'S

LOCKERS &

SHOWER

HALL

IT

PRODUCTION

017D

HALL

HALL

SOUND BOOTH

017C MULTIMEDIA

STORAGE

UNASSIGNED

UNASSIGNED

9 888 8 8 8 8

OFFICE

OFFICE

CONFERENCE

OFFICE

OFFICE

CONFERENCE

TELECOM

9 9 9

9 9 9

A.

B.

C.

D.

E.

THESE DRAWINGS ARE BASED UPON EXISTING

DRAWINGS AND SITE OBSERVATIONS. THE

CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL

CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING

WORK.

PROTECT ALL EXISTING ITEMS TO REMAIN FROM

DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED

DURING CONSTRUCTION, INCLUDING VOIDS AND

FINISHES RESULTING FROM DEMOLITION REMOVALS.

MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL

NEW CONSTRUCTION.

SEE ABATEMENT, FIRE ALARM, FIRE PROTECTION,

PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS

AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

WHERE EXISTING FLOOR FINISHES ARE REMOVED, PREP

SLAB AND/OR UNDERLAYMENT AS REQUIRED TO

RECEIVE NEW FLOOR FINISHES NOTED.

GENERAL SHEET NOTES

EXISTING ROOM NAME AND NUMBER

KEYNOTE

DRAWING NUMBER

SHEET WHERE DRAWN

DIMENSION TO FACE OF FRAMING

DIMENSION TO GRID LINE

XXX000

SIM

NAME

X

DEMO PLAN LEGEND

DIRECTION OF VIEW, IF APPLICABLE

DIMENSION TO CENTER LINE

CL

ITEMS TO BE DEMOLISHED

ITEMS TO REMAIN

SURFACE TO BE DEMOLISHED. SEE

KEYNOTES FOR DETAILS.

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:5

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

BA

SE

M

EN

T D

EM

O

LI

TI

O N

PL

AN

M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

AD100

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

9 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

A1 BASEMENT DEMOLITION PLAN

0 4' 8' 16'

N

# SHEET KEYNOTES

1 DEMOLISH EXISTING STAIR AND RAILINGS IN THEIR

ENTIRETY. PATCH, REPAIR AND PREP AREA FOR NEW

FINISHES.

2 DEMOLISH EXISTING INTERIOR WALL FURRING AND ALL

ASSOCIATED ITEMS TO EXTENTS SHOWN DOWN TO

EXISTING COLUMN OR CMU WALL. PATCH AND REPAIR

EXISTING COLUMN OR CMU WALL TO REMAIN WHERE

DAMAGE OCCURS. PREPARE SURFACE FOR NEW

CONSTRUCTION. COORDINATE WITH OTHER DEMOLITION

DRAWINGS.

3 DEMOLISH EXISTING WALL AND ASSOCIATED ITEMS TO

EXTENTS SHOWN. PATCH AND REPAIR ADJACENT

EXISTING WALLS TO REMAIN WHERE DAMAGE OCCURS.

COORDINATE WITH OTHER DEMOLITION DRAWINGS

4 DEMOLISH EXISTING DOOR, FRAME AND ALL HARDWARE.

5 DEMOLISH RAISED FLOOR IN ENTIRETY DOWN TO

CONCRETE TO BE FLUSH WITH ADJACENT FLOOR IN

HALL 026. PREPARE FLOOR SURFACE FOR NEW

CONSTRUCTION.

6 DEMOLISH EXISTING CARPET FLOORING WITHIN ROOM

NOTED. REMOVE EXISTING FLOORING DOWN TO

EXISTING CONCRETE SLAB. PREP FOR NEW FLOORING.

DEMOLISHED CARPET TO PALLETIZED TO BE PICKED UP

FOR RECYCLING. SEE SPECS FOR DETAILS.

7 DEMOLISH STAIR, RAMP, AND RAILINGS IN THEIR

ENTIRETY. PATCH, REPAIR AND PREP AREA FOR NEW

FINISHES.

8 DEMOLISH EXISTING EXTERIOR WALL FURRING DOWN

TO CONCRETE FOUNDATION WALL. PATCH AND REPAIR

ANY DAMAGE. PREPARE SURFACE FOR NEW

CONSTRUCTION. COORDINATE WITH OTHER DEMOLITION

DRAWINGS.

9 REMOVE WALL PANELING, FURRING, AND ALL

ASSOCIATED ITEMS DOWN TO CMU WALL. PREPARE

WALL FOR NEW CONSTRUCTION.

10 REMOVE EXISTING DOOR FRAME, AND PREP OPENING

FOR NEW DOOR AND FRAME.

11 REMOVE EXISTING CONCRETE AS REQUIRED FOR

ELECTRICAL FLOOR BOX INSTALL. PREP FOR NEW

CONCRETE.

12 EXISTING F.E.C. TO REMAIN, PROTECT FROM DAMAGE.

13 EXISTING F.E. TO REMAIN, PROTECT FROM DAMAGE.

14 EXISTING FLOORING TO REMAIN. PROTECT FROM

DAMAGE.

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

EF

0.19 12345678

D

C

B

A

B.1

C.1

C.2

FOCUS

IDF

4 4

3 33

5 5

1 1 1

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

LOBBY

HALL

110OFFICE

OFFICE

OFFICE

WEST STAIR

HALL

OFFICE

122 LEO-CONF

RESTROOM

BREAK ROOM

WELLNESS

STORAGE

WOMEN'S

MEN'S

HALL

UTILITY

JANITOR

HD FILES

DUCT-

CHASE

STORAGE

EAST STAIR

ELEVATOR

HALL

WORK/MAIL 131

MEDIUM

CONFERENCE

HUDDLE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

3 3

A.

B.

C.

D.

E.

THESE DRAWINGS ARE BASED UPON EXISTING

DRAWINGS AND SITE OBSERVATIONS. THE

CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL

CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING

WORK.

PROTECT ALL EXISTING ITEMS TO REMAIN FROM

DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED

DURING CONSTRUCTION, INCLUDING VOIDS AND

FINISHES RESULTING FROM DEMOLITION REMOVALS.

MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL

NEW CONSTRUCTION.

SEE ABATEMENT, FIRE ALARM, FIRE PROTECTION,

PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS

AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

WHERE EXISTING FLOOR FINISHES ARE REMOVED, PREP

SLAB AND/OR UNDERLAYMENT AS REQUIRED TO

RECEIVE NEW FLOOR FINISHES NOTED.

GENERAL SHEET NOTES

EXISTING ROOM NAME AND NUMBER

KEYNOTE

DRAWING NUMBER

SHEET WHERE DRAWN

DIMENSION TO FACE OF FRAMING

DIMENSION TO GRID LINE

XXX000

SIM

NAME

X

DEMO PLAN LEGEND

DIRECTION OF VIEW, IF APPLICABLE

DIMENSION TO CENTER LINE

CL

ITEMS TO BE DEMOLISHED

ITEMS TO REMAIN

SURFACE TO BE DEMOLISHED. SEE

KEYNOTES FOR DETAILS.

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:5

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

FI

R

ST

F

LO

O

R D

EM

O

LI

TI

O N

PL

AN

M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

AD101

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

10 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

A1 FIRST FLOOR DEMOLITION PLAN

0 4' 8' 16'

N

# SHEET KEYNOTES

1 DEMOLISH EXISTING EXTERIOR WALL FURRING DOWN

TO CONCRETE WALL. PATCH AND REPAIR ANY DAMAGE.

PREPARE SURFACE FOR NEW CONSTRUCTION.

COORDINATE WITH OTHER DEMOLITION DRAWINGS.

2 DEMOLISH EXISTING INTERIOR WALL FURRING AND ALL

ASSOCIATED ITEMS TO EXTENTS SHOWN DOWN TO

EXISTING COLUMN. PATCH AND REPAIR EXISTING

COLUMN TO REMAIN WHERE DAMAGE OCCURS.

PREPARE SURFACE FOR NEW CONSTRUCTION.

COORDINATE WITH OTHER DEMOLITION DRAWINGS.

3 DEMOLISH EXISTING WALL AND ASSOCIATED ITEMS TO

EXTENTS SHOWN. PATCH AND REPAIR ADJACENT

EXISTING WALLSTO REMAIN WHERE DAMAGE OCCURS.

COORDINATE WITH OTHER DEMOLITION DRAWINGS

4 DEMOLISH EXISTING DOOR, FRAME AND ALL HARDWARE.

5 DEMOLISH EXISTING CARPET FLOORING WITHIN ROOM

NOTED. REMOVE EXISTING FLOORING DOWN TO

EXISTING CONCRETE SLAB AND PREP FOR NEW

FLOORING. REMOVED CARPET TO BE PALLETIZED FOR

RECYCLING. SEE SPECS FOR DETAILS.

6 EXISTING EXTERIOR WINDOW ASSEMBLY TO REMAIN.

PROTECT FROM DAMAGE.

7 REMOVE EXISTING WALL BOARD OFF OF EXISTING

STUDS FOR FULL LENGH AND HEIGHT OF WALL

INDICATED FOR ASBESTOS ABATEMENT. SEE

ABATEMENT DRAWINGS AND SPECIFICATIONS ALSO.

REMOVE WOOD PANELING BEHIND GYPSUM

WALLBOARD WHERE OCCURS.

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

C

B

A

B.1

C.1

C.2

STORAGE

004A

STORAGE

SOUND

STUDIO

017B

BID ADDITIVE #1

11111111

MEP

UNASSIGNED

UNASSIGNED

STORAGE

003A

LOCKERS &

SHOWER

HALL

HALL

IT

PRODUCTION

017D

MEN'S

WOMEN'S

JAN

HALL

HALL

EAST STAIR

WEST STAIR

UNASSIGNED

UNASSIGNED

SOUND BOOTH

017C MULTIMEDIA

STORAGE

HALL

ELEVATOR

CONTROL

OFFICE

OFFICE

CONFERENCE

OFFICE

OFFICE

CONFERENCE

TELECOM

A.

B.

C.

D.

E.

THESE DRAWINGS ARE BASED UPON EXISTING

DRAWINGS AND SITE OBSERVATIONS. THE

CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL

CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING

WORK.

PROTECT ALL EXISTING ITEMS TO REMAIN FROM

DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED

DURING CONSTRUCTION, INCLUDING VOIDS AND

FINISHES RESULTING FROM DEMOLITION REMOVALS.

MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL

NEW CONSTRUCTION.

SEE ABATEMENT, FIRE ALARM, FIRE PROTECTION,

PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS

AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

EXISTING CEILINGS AND ASSOCIATED MECHANICAL AND

ELECTRICAL ELEMENTS ARE SHOWN FOR

COORDINATION PURPOSES FOR THE NECESSARY

DISCIPLINES. VERIFY ALL ITEMS IN FIELD.

GENERAL SHEET NOTES

EXISTING ROOM NAME AND NUMBER

KEYNOTE

DRAWING NUMBER

SHEET WHERE DRAWN

DIMENSION TO FACE OF FRAMING

DIMENSION TO GRID LINE

XXX000

SIM

NAME

X

PLAN LEGEND

DIRECTION OF VIEW, IF APPLICABLE

DIMENSION TO CENTER LINE

CL

ITEMS TO BE DEMOLISHED

ITEMS TO REMAIN

SURFACE TO BE DEMOLISHED. SEE

KEYNOTES FOR DETAILS.

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:5

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

BA

SE

M

EN

T D

EM

O

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

AD102

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

11 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

A1 BASEMENT DEMO REFLECTED CEILING PLAN

1 DEMOLISH EXISTING CEILING, GRIDS, SUSPENSION

SYSTEMS, AND LIGHT FIXTURES IN THEIR ENTIRETY.

SEE FIRE, PLUMBING, MECHANICAL, AND ELECTRICAL

DRAWINGS FOR OTHER WORK TO OCCUR WITHIN

ROOM.

2 EXISTING CEILING TO REMAIN. REMOVE GRID AND

TILES AS NEEDED FOR ADJACENT WALL DEMOLITION

AND CONSTRUCTION. REINSTALL GRID AND TILES

AFTER WALL CONSTRUCTION IS COMPLETED.

# SHEET KEYNOTES

0 4' 8' 16'

N # De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

C

B

A

B.1

C.1

C.2

OFFICE

134A

OFFICE

134B

OPEN OFFICE

OPEN OFFICE

IDF

FOCUS

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

VESTIBULE

LOBBY

HALL

MEN'S

WOMEN'S

JANITOR

UTILITY

DUCT-

CHASE

STORAGE

HD FILES

HALL

OFFICE

OFFICE

OFFICE

WEST STAIR

HALL

OFFICE

LEO-CONF

RESTROOM

107 BREAK ROOM

WELLNESS

STORAGE

HALL

ELEVATOR

EAST STAIR

1 1

A.

B.

C.

D.

E.

THESE DRAWINGS ARE BASED UPON EXISTING

DRAWINGS AND SITE OBSERVATIONS. THE

CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL

CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING

WORK.

PROTECT ALL EXISTING ITEMS TO REMAIN FROM

DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED

DURING CONSTRUCTION, INCLUDING VOIDS AND

FINISHES RESULTING FROM DEMOLITION REMOVALS.

MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL

NEW CONSTRUCTION.

SEE ABATEMENT, FIRE ALARM, FIRE PROTECTION,

PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS

AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.

EXISTING CEILINGS AND ASSOCIATED MECHANICAL AND

ELECTRICAL ELEMENTS ARE SHOWN FOR

COORDINATION PURPOSES FOR THE NECESSARY

DISCIPLINES. VERIFY ALL ITEMS IN FIELD.

GENERAL SHEET NOTES

EXISTING ROOM NAME AND NUMBER

KEYNOTE

DRAWING NUMBER

SHEET WHERE DRAWN

DIMENSION TO FACE OF FRAMING

DIMENSION TO GRID LINE

XXX000

SIM

NAME

X

PLAN LEGEND

DIRECTION OF VIEW, IF APPLICABLE

DIMENSION TO CENTER LINE

CL

ITEMS TO BE DEMOLISHED

ITEMS TO REMAIN

SURFACE TO BE DEMOLISHED. SEE

KEYNOTES FOR DETAILS.

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:0

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

FI

R

ST

F

LO

O

R D

EM

O

R

EF

LE

C

TE

D

C

EI

LI

N

G P

LA

N

M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

AD103

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

12 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

A1 FIRST FLOOR DEMO REFLECTED CEILING PLAN

# SHEET KEYNOTES

0 4' 8' 16'

N

1 DEMOLISH EXISTING CEILING, GRIDS, SUSPENSION

SYSTEMS, AND LIGHT FIXTURES IN THEIR ENTIRETY.

SEE FIRE, PLUMBING, MECHANICAL, AND ELECTRICAL

DRAWINGS FOR OTHER WORK TO OCCUR WITHIN

ROOM.

2 DEMOLISH EXISTING CEILING GRID AND TILES TO

EXTENT SHOWN. PREPARE EXISTING ADJACENT GRID

FOR INSTALLATION OF NEW CEILING IN THIS AREA. SEE

CONSTRUCTION PLANS ALSO.

3 EXISTING CEILING TO REMAIN. REMOVE GRID AND

TILES AS NEEDED FOR ADJACENT WALL DEMOLITION

AND CONSTRUCTION. REINSTALL GRID AND TILES

AFTER WALL CONSTRUCTION IS COMPLETED.

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

WALL ASSEMBLIES

A

EXISTING EXTERIOR

CONCRETE WALL

3" MINERAL WOOL BOARD

INSULATION. R-11.4 MINIMUM

2 1/2" METAL STUDS AT

24" O.C.

5/8" TYPE 'X' GYPSUM

BOARD

EXISTING EXT WALL FURRING

B

EXISTING EXTERIOR

CONCRETE COLUMN3" MINERAL WOOL BOARD

INSULATION. R-11.4 MINIMUM

5/8" TYPE 'X' GYPSUM BOARD

EXISTING EXT COLUMN FURRING

J

SOUND BATT INSULATION

3 5/8" METAL STUDS AT 16" O.C.

5/8" TYPE 'X' GYPSUM BOARD

INTERIOR SOUND PARTITION - STC 49

L

EXISTING CONCRETE COLUMN

OR CMU WALL (SEE PLANS)

1 1/2" METAL HAT CHANNELS AT

24" O.C.

5/8" TYPE 'X' GYPSUM BOARD

INTERIOR COLUMN FURRING

5/8" TYPE 'X' GYPSUM BOARD

K

SOUND BATT INSULATION

3 5/8" METAL STUDS AT 16" O.C.

INTERIOR FURRING

5/8" TYPE 'X' GYPSUM BOARD

C

EXISTING EXTERIOR

CONCRETE WALL

2" MINERAL WOOL BOARD

INSULATION. R-7.6

MINIMUM

2 1/2" METAL STUDS AT

24" O.C.

5/8" TYPE 'X' GYPSUM

BOARD

EXISTING EXT BASEMENT WALL FURRING

3" THERMALLY

BROKEN Z-GIRT AT 24"

O.C.

3" THERMALLY BROKEN

Z-GIRT AT 24" O.C.

2" THERMALLY BROKEN

Z-GIRT AT 24" O.C.

F

INTERIOR WALL FURRING

3 5/8" METAL STUDS AT 16" O.C.

5/8" TYPE 'X' GYPSUM BOARD

EXISTING CONCRETE WALL

(SEE PLANS)

SCALE: 1" = 1'-0"

A.

B.

C.

1.

GENERAL WALL TYPE NOTES:

SEE INTERIOR ELEVATIONS (SHEET A801) AND

FINISH SCHEDULE (SHEET A501) FOR WALL

FINISHES.

PROVIDE BLOCKING AS REQUIRED TO SECURE

WALL HUNG COMPONENTS.

EXTEND ALL COMPONENTS TO UNDERSIDE OF

DECK, UNLESS NOTED OTHERWISE.

WALL TYPE MODIFIERS:

NOT USED.

WALL TYPE LEGEND

WALL TYPE DESCRIPTION

W1

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:0

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

LE

G

EN

D

, N O

TE

S, A N

D W

AL

L

TY

PE

S M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

AE001

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

13 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

C

B

A

B.1

C.1

C.2

021-1

1-

LARGE MEETING

ROOM

4-

4-

STORAGE

004A MEETING ROOM

LARGE MEETING

ROOM

MEETING ROOM

LARGE MEETING

ROOM

STORAGE

HALL

HALL

BID ADDITIVE #1

SOUND

STUDIO

017B

MEP

UNASSIGNED

UNASSIGNED

UNASSIGNED

UNASSIGNED

STORAGE

003A

WEST STAIR

HALL

LOCKERS &

SHOWER

MEN'S

IT

PRODUCTION

017D

MULTIMEDIA

STORAGE

EAST STAIR

WOMEN'S

JAN

L

J

J J

L

L L

C

CCCCCC

C

004A

L

L

L

L

L

L

L

L

LL

L

L L

C

L

L L

L L

C CC

L

L L

C CC

AE504

B2

ASSEMBLY TYPE (SEE ASSEMBLIES SHEET)

ASSEMBLY MODIFIER, PER TYPE

ROOM NAME AND NUMBER

WINDOW TYPE (SEE A600s)

KEYNOTE

DRAWING NUMBER

SHEET WHERE DRAWN

DOOR NUMBER (SEE SHEET A601)

DIMENSION TO FACE OF FRAMING

DIMENSION TO GRID LINE

1-

XXX000

SIM

X

XX

NAME

X

X

PLAN LEGEND

DIRECTION OF VIEW, IF APPLICABLE

DIMENSION TO CENTER LINE

CL

NEW CONCRETE PATCH

A.

B.

C.

D.

E.

F.

G.

CONTRACTOR TO FIELD VERIFY ALL EXISTING

CONDITIONS

REFER TO CODE PLANS FOR LOCATIONS OF ANY

RATED DOORS AND ASSEMBLIES

FOR ANY WALLS NOT LABELLED, USE TYPE MOST

CONSISTENT WITH SIMILAR

APPLICATIONS/LOCATIONS.

ALL STUD WALLS TO HAVE 5" STUD RETURN AT

DOORS BETWEEN STUD OPENINGS TO

PERPENDICULAR WALL AT HINGE SIDE OF DOOR.

SEE ENLARGED PLANS FOR WALL TYPES, TAGS

DIMENSIONS, AND ADDITIONAL INFORMATION FOR

AREAS SHOWN IN CALLOUTS.

ELECTRICAL REQUIREMENTS TO BE COORDINATED

WITH FURNITURE VENDOR.

SEE ABATEMENT, FIRE ALARM, FIRE PROTECTION,

PLUMBING, MECHANICAL, AND ELECTRICAL

DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL

REQUIREMENTS.

GENERAL SHEET NOTES

1 2 3 4 5

D

C

B

A

Sh ee t T itl e:

D es ig ne d by

D ra w n by

C he ck ed b y:

Ap pr ov ed b y:

R ev is io ns

U ni te d

St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d

M an ag em en t

BLM Project #

Project #

Date:

ALWAYS THINK SAFETY Sheet of

/2

/2

2:

:0

PM

U :\t yl er m or te ns on \D oc um en ts

R ev itL oc al

Te m p\

LB

YD

BL

M

_T O

_a rc h2

4_ ty le rm or te ns on

.rv t

BA

SE

M

EN

T

FL

O O

R P

LA

N

M O

R

TE

N

SO

N

G R

AB

ST

EI

N

M O

R

TE

N

SO

N

SJ

BD

N

IF

C

-A

D M

IN

IS

TR

AT

IO

N

R

EP

AI

R

S

FY

G

AO

A

S D ev el op m en t A ve , B oi se

, I D

140L0622D002

070117.028

12.2.2025

AE100

N

AT

IO

N

AL

IN

TE

R

AG

EN

C Y

FI

R

E C

EN

TE

R

14 67

IS

SU

ED

F

O R

C O

N

ST

R U

C

TI

O N

A1 BASEMENT FLOOR PLAN

0 4' 8' 16'

N

# SHEET KEYNOTES

1 EXISTING F.E.C. TO REMAIN, PROTECT FROM

DAMAGE.

2 EXISTING F.E. TO REMAIN. PROTECT FROM

DAMAGE.

3 PATCH AND REPAIR EXISTING CMU WALL WHERE

STAIR & RAILING WERE REMOVED. PAINT TO

MATCH ADJACENT WALL SURFACE

4 EXISTING OPENING IN EXTERIOR WALL FROM

PRIOR CONSTRUCTION PROJECT. INFILL OPENING

WITH MINIMUM R-12 MINERAL WOOL INSULATION.

5 PATCH CONCRETE SLAB ON GRADE AFTER

ELECTRICAL FLOOR BOX INSTALLATION. MATCH

EXISTING SLAB THICKNESS.

De sc rip tio n

Da te

IS

SU

ED

F

OR

C

ON

ST

RU

CT

IO

N

EF

0.19 12345678

D

C

B

A

B.1

C.1

C.2

5'

1/

2"

2' - 6"

9'

1/

2"

11' - 2 3/4"

2'

134-1

4-

4A

4B

1' - 6" 9' - 8"

OPEN OFFICE

HALL

OPEN OFFICE

OFFICE

134B

OFFICE

134A

FOCUS

IDF

OFFICE

OFFICE

OFFICE

OFFICE

OFFICE

111 VESTIBULE

LOBBY

HALL

OFFICE

OFFICE

OFFICE

HALL

OFFICE

LEO-CONF

RESTROOM

BREAK ROOM

WELLNESS