B08_Att16_26R0002_Revised_Select_Drawings_0001.pdf
PDF 9 MB Posted
- Attached to
- NIFC 100-ADM Repairs Federal contract opportunity
- Solicitation number
- 140L0626R0002
About this file
This document is a set of architectural and engineering design plans for the National Interagency Fire Center (NIFC) 100-Administration Building Repairs project located at 3833 S Development Ave, Boise, Idaho 83705, funded through FY 2022 GAOA (General Services Administration). The project is administered by the United States Department of the Interior Bureau of Land Management.
The plans encompass basement, first floor, and second floor layouts with comprehensive code compliance analysis, demolition plans, abatement requirements, and fire alarm system design. The building is classified as Business Occupancy, Type II-000 Construction (sprinklered), with 294 occupants in the base bid and 364 occupants in Bid Additive #1. Plumbing fixture requirements per IBC Table 2902.1 are specified, including water closets, lavatories, drinking fountains, and service sinks. The project includes asbestos abatement work with identified materials containing chrysotile in drywall mud (approximately 3%), tile, and mastic. Wall assemblies feature 2.5-inch metal studs with gypsum board, mineral wool insulation, and thermally broken Z-girts for basement exterior walls. Fire alarm system design includes addressable smoke and heat detectors, manual pull stations, notification devices, and monitoring modules distributed throughout the facility with connection to a remote supervising station. The design incorporates code compliance with NFPA 101 (2021), NFPA 72, IBC, IFC, and NEC standards, with detailed specifications for exit corridors, fire partitions, and means of egress.
View the file
Other files for this federal contract opportunity
Show all 22
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
88888 SF= ######
ROOM NAME SPACE AREA
OCCUPANCY TAG:
NUMBER OF OCCUPANTS
OCCUPANT LOAD FACTOR
FIRE EXTINGUISHER CABINET AND
EXTINGUISHER - SEE SPECIFICATIONS
M
UL RATED FIRE DOOR AND FRAME WITH
RATING AS INDICATED
- SEE SHEET AE601
ROOM / AREA NAME
ROOM / AREA NUMBER
EXIT PATH
SURFACE MOUNTED FIRE
EXINGUISHER - SEE SPECIFICATIONS
# CODE PLAN LEGEND
EGRESS LIGHTING (EXIT SIGNS) - SEE
ELECTRICAL DRAWINGS
B / BUSINESS OCCUPANCY
S2 / STORAGE OCCUPANCY
EXIT TAG:
REQUIRED WIDTH
OCCUPANT LOAD
PROVIDED WIDTH
FEC
FE
EXISTING 1 HOUR FIRE BARRIER - SEAL
PERIMETER AND PENETRATIONS PER
DETAILS ON GI103
CODE REVIEW INFORMATION
THIS ANALYSIS BASED ON BASE BID CONSTRUCTION. FOR BID ADDITIVE #1, SEE GI102.
GOVERNING CODES:
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 NFPA 101 LIFE SAFETY CODE
ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS
*SHOULD A CONFLICT EXIST BETWEEN BLM ADOPTED CODES AND STATE OR LOCAL
CODES, BLM ADOPTED CODES SHALL PREVAIL
IEBC 2021 ANALYSIS:
CLASSIFICATION OF WORK: LEVEL 2 ALTERATION
603.1 LEVEL 2 ALTERATIONS INCLUDE THE ADDITION OR ELIMINATION OF ANY DOOR OR
WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE
INSTALLATION OF ANY ADDITIONAL EQUIPMENT, AND SHALL APPLY WHERE THE WORK
AREA IS EQUAL TO OR LESS THAN 50 PERCENT OF THE BUILDING AREA.
603.2 LEVEL 2 ALTERATIONS SHALL COMPLY WITH PROVISIONS OF CHAPTER 7 AND 8
701.2 AN EXISTING BUILDING OR PORTION THERE OF SHALL NOT BE ALTERED SUCH
THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION.
703.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE
PROTECTION PROVIDED.
801.4 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND SPACES SHALL
COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.
802.4 THE INTERIOR FINISH AND TRIM OF WALLS AND CEILINGS IN EXITS AND
CORRIDORS IN ANY WORK AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE
INTERNATIONAL BUILDING CODE.
809.1 LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS ARE PERMITTED WITHOUT
REQUIRING THE ENTIRE BUILDING TO COMPLY WITH THE ENERGY REQUIREMENTS OF
THE INTERNATIONAL ENERGY CONSERVATION CODE. ALTERATIONS SHALL CONFORM
TO THE ENERGY REQUIREMENTS OF TEH INTERNATIONAL ENERGY CONSERVATION
CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.
IBC 2021 ANALYSIS
OCCUPANCY CLASSIFICATION: B (BUSINESS), S-2 (STORAGE) PER SECTION 304.1
BUILDING OCCUPANCY HAS NOT BEEN ALTERED FROM EXISTING
FIRE SPRINKLER SYSTEM: PROVIDED
CONSTRUCTION TYPE: IIB PER SECTION 602.2
BUILDING HEIGHT, AREA, AND NUMBER OF STORIES: NOT ALTERED FROM EXISTING
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601
FOR TYPE IIB, ALL ELEMENTS EXCEPT EXTERIOR WALLS = 0 HOURS
SECTION 602.2 TYPES I AND II
TYPES I AND II CONSTRUCTION ARE THOSES TYPES OF CONSTRUCTION IN WHICH
THE BUILDING ELEMENTS SPECIFIED IN TBALE 601 ARE OF NONCOMBUSTIBLE
MATERIALS, EXCEPT AS PERMITTED IN SECTION 603 AND ELSEWHERE IN THIS CODE.
CHAPTER 7 RATED / PROTECTED ASSEMBLIES NOT ALTERED FROM EXISTING
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE
803.13
FOR GROUP B, SPRINKLERED (MOST STRINGENT):
EXIT ENCLOSURES AND EXIT PASSAGEWAYS = B
CORRIDORS & STIARWAYS = C
ROOMS AND ENCLOSED SPACES = C
OCCUPANT LOAD FACTOR FROM TABLE 1004.5 ASSIGNED TO EACH ROOM, TOTALS:
BASEMENT AREAS = 92 OCCUPANTS
FIRST FLOOR AREAS = 93 OCCUPANTS
SECOND FLOOR AREAS = 109 OCCUPANTS
TOTAL OCCUPANCY 294 OCCUPANTS
1.
2.
MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3
STAIRWAYS, SPRINKLERED, GROUP B/S = 0.2 INCHES PER OCCUPANT
OTHER EGRESS COMPONENTS, SPRINKLERED, GROUP B = 0.15 INCHES PER
OCCUPANT
SEE CODE PLANS FOR REQUIRED AND PROVIDED EXIT WIDTHS
EGRESS CONVERGANCE FROM SECTION 1005.6
WHERE THE MEANS OF EGRESS FROM STORIES ABOVE AND BELOW CONVERGE AT
AN INTERMEDIATE LEVEL, THE CAPACITY OF THE MEANS OF EGRESS FROM THE
POINT OF CONVERGENCE SHALL BE NOT LESS THAN THE LARGEST MINIMUM WIDTH
OR THE SUM OF THE REQUIRED CAPACITIES FOR THE STAIRWAYS SERVING THE TWO
ADJACENT STORIES, WHICHEVER IS LARGER.
COMMON PATH OF EGRESS TRAVEL PER TABLE 1006.2.1 =
FOR B OCCUPANCY ROOMS = SHALL NOT EXCEED 100 FEET
SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1
FOR B OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 49
FOR S OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 29
EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2
FOR B OCCUPANCY (MOST STRINGENT), WITH SPRINKLER SYSTEM = 300 FEET
CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.2
FOR B, S OCCUPANCY, WITH SPRINKLER SYSTEM = NO RATING IS REQUIRED
MINIMUM CORRIDOR WIDTH PER TABLE 1020.3 = 44 INCHES.
DEAD END CORRIDORS FROM SECTION 1020.5 EXCEPTION 2
FOR B, S OCCUPANCY, SPRINKLERRED = NO MORE THAN 50 FEET
IECC 2021 ASSEMBLY INFORMATION (A001 FOR ASSEMBLY TYPES)
BOISE, IDAHO | ADA COUNTY - ZONE 5B
SEE ELECTRICAL DRAWINGS FOR DAYLIGHT ZONE LIGHTING CONTROLS
PER TABLE C402.1.3. THE BUILDING ENVELOPE WILL MEET OR EXCEED THE BELOW:
MASS - R-11.4ci WALLS BELOW GRADE - R-7.5c.i. (CONTINUOUS INSULATION)
543 SF = 3715
LARGE MEETING
ROOM
62 SF = 1300
STORAGE
004A
339 SF = 3150
HALL
268 SF = 2150
HALL
108 SF = 1150
SOUND
STUDIO
017B
1250 SF = 9150
MEP
159 SF = 2150
UNASSIGNED
42 SF = 1150
UNASSIGNED
37 SF = 1150
UNASSIGNED
165 SF = 2150
UNASSIGNED
125 SF = 1300
STORAGE
003A
230 SF = 2150
WEST STAIR
111 SF = 1150
HALL
65 SF = 1150
LOCKERS &
SHOWER
89 SF = 1150
MEN'S
250 SF = 2150
IT
452 SF = 4150
PRODUCTION
017D
241 SF = 1300
MULTIMEDIA
STORAGE
232 SF = 2150
EAST STAIR
117 SF = 1150
WOMEN'S
25 SF = 1300
JAN
69 SF = 1150
HALL
49 SF = 1150
ELEVATOR
35 SF = 1150
SOUND BOOTH
017C
EXIT ACCESS TRAVEL DISTANCE
77' - 8"
EXIT SEPARATION
112' - 10"
FEC FEC
6.6"
60"
4.95"
36"
4.8"
36"626.
4"
STORAGE
HALL
81 SF = 1150
CONTROL
DIAGONAL DISTANCE140' - 2"
FE
FINISH FLOOR
4'
- 6
TO
H
AN
DL
E 4'
- 0
MA
X
SEMI-RECESSED FIRE
EXTINGUISHER
CABINET
PORTABLE
FIRE
EXTINGUISHER
C4 EXTINGUISHER MOUNTING HEIGHTS
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
:1 7:
P
M \\y sv
9.
ct ag ro up .n et \u se rd at a\ be nj am in gr ab st ei n\ D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ be nj am in gr ab st ei n.
rv t
C O
D E
SH
EE
T
BA
SE
M
EN
T
M O
R
TE
N
SO
N
G R
AB
ST
EI
N
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
GI100
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
3 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
B1 BASEMENT CODE PLAN
0 4' 8' 16'
MINIMUM NUMBER OF PLUMBING FIXTURES PER IBC TABLE 2902.1
BASED ON BUSINESS OCCUPANCY (MOST STRINGENT)
294 OCCUPANTS = 147 MALE, 147 FEMALE
THIS ANALYSIS BASED ON BASE BID CONSTRUCTION. FOR BID ADDITIVE, SEE
GI102.
2901.1.2
THE TOTAL NUMBER OF FIXTURES SHALL BE PERMITTED TO BE BASED ON THE
REQUIRED NUMBER OF SEPARATE FACILITIES OR BASED ON THE AGGREGATE
OF ANY COMBINATION OF SINGLE-USER OR SEPARATE FACILITIES
WATER CLOSETS:
1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50
PER IPC 424.2, URINAL SHALL NOT BE SUBSTITUTED FOR MORE THAN 50
PERCENT OF REQUIRED WATER CLOSETS
REQUIRED: 4 MALE,4 FEMALE
PROVIDED: 4 MALE, 3 FEMALE, 4 UNISEX
LAVATORIES:
1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80
FOR BOTH MALE AND FEMALES
REQUIRED: 3 MALE, 3 FEMALE
PROVIDED: 2 MALE, 2 FEMALE, 4 UNISEX
DRINKING FOUNTAINS:
1 PER 100
REQUIRED: 3 TOTAL
PROVIDED: 5
SERVICE SINK:
REQUIRED: 1 TOTAL
PROVIDED: 3
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.02
.25
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
.14 .26
N scottr Text Box
BID CLARIFICATION
scottr Line
DN
R
EF
88888 SF= ######
ROOM NAME SPACE AREA
OCCUPANCY TAG:
NUMBER OF OCCUPANTS
OCCUPANT LOAD FACTOR
FIRE EXTINGUISHER CABINET AND
EXTINGUISHER - SEE SPECIFICATIONS
M
UL RATED FIRE DOOR AND FRAME WITH
RATING AS INDICATED
- SEE SHEET AE601
ROOM / AREA NAME
ROOM / AREA NUMBER
EXIT PATH
SURFACE MOUNTED FIRE
EXINGUISHER - SEE SPECIFICATIONS
# CODE PLAN LEGEND
EGRESS LIGHTING (EXIT SIGNS) - SEE
ELECTRICAL DRAWINGS
B / BUSINESS OCCUPANCY
S2 / STORAGE OCCUPANCY
EXIT TAG:
REQUIRED WIDTH
OCCUPANT LOAD
PROVIDED WIDTH
FEC
FE
EXISTING 1 HOUR FIRE BARRIER - SEAL
PERIMETER AND PENETRATIONS PER
DETAILS ON GI103
CODE REVIEW INFORMATION
THIS ANALYSIS BASED ON BASE BID CONSTRUCTION. FOR BID ADDITIVE #1, SEE GI102.
GOVERNING CODES:
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 NFPA 101 LIFE SAFETY CODE
ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS
*SHOULD A CONFLICT EXIST BETWEEN BLM ADOPTED CODES AND STATE OR LOCAL
CODES, BLM ADOPTED CODES SHALL PREVAIL
IEBC 2021 ANALYSIS:
CLASSIFICATION OF WORK: LEVEL 2 ALTERATION
603.1 LEVEL 2 ALTERATIONS INCLUDE THE ADDITION OR ELIMINATION OF ANY DOOR OR
WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE
INSTALLATION OF ANY ADDITIONAL EQUIPMENT, AND SHALL APPLY WHERE THE WORK
AREA IS EQUAL TO OR LESS THAN 50 PERCENT OF THE BUILDING AREA.
603.2 LEVEL 2 ALTERATIONS SHALL COMPLY WITH PROVISIONS OF CHAPTER 7 AND 8
701.2 AN EXISTING BUILDING OR PORTION THERE OF SHALL NOT BE ALTERED SUCH
THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION.
703.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE
PROTECTION PROVIDED.
801.4 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND SPACES SHALL
COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.
802.4 THE INTERIOR FINISH AND TRIM OF WALLS AND CEILINGS IN EXITS AND
CORRIDORS IN ANY WORK AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE
INTERNATIONAL BUILDING CODE.
809.1 LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS ARE PERMITTED WITHOUT
REQUIRING THE ENTIRE BUILDING TO COMPLY WITH THE ENERGY REQUIREMENTS OF
THE INTERNATIONAL ENERGY CONSERVATION CODE. ALTERATIONS SHALL CONFORM
TO THE ENERGY REQUIREMENTS OF TEH INTERNATIONAL ENERGY CONSERVATION
CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.
IBC 2021 ANALYSIS
OCCUPANCY CLASSIFICATION: B (BUSINESS), S-2 (STORAGE) PER SECTION 304.1
BUILDING OCCUPANCY HAS NOT BEEN ALTERED FROM EXISTING
FIRE SPRINKLER SYSTEM: PROVIDED
CONSTRUCTION TYPE: IIB PER SECTION 602.2
BUILDING HEIGHT, AREA, AND NUMBER OF STORIES: NOT ALTERED FROM EXISTING
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601
FOR TYPE IIB, ALL ELEMENTS EXCEPT EXTERIOR WALLS = 0 HOURS
SECTION 602.2 TYPES I AND II
TYPES I AND II CONSTRUCTION ARE THOSES TYPES OF CONSTRUCTION IN WHICH
THE BUILDING ELEMENTS SPECIFIED IN TBALE 601 ARE OF NONCOMBUSTIBLE
MATERIALS, EXCEPT AS PERMITTED IN SECTION 603 AND ELSEWHERE IN THIS CODE.
CHAPTER 7 RATED / PROTECTED ASSEMBLIES NOT ALTERED FROM EXISTING
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE
803.13
FOR GROUP B, SPRINKLERED (MOST STRINGENT):
EXIT ENCLOSURES AND EXIT PASSAGEWAYS = B
CORRIDORS & STIARWAYS = C
ROOMS AND ENCLOSED SPACES = C
OCCUPANT LOAD FACTOR FROM TABLE 1004.5 ASSIGNED TO EACH ROOM, TOTALS:
BASEMENT AREAS = 92 OCCUPANTS
FIRST FLOOR AREAS = 93 OCCUPANTS
SECOND FLOOR AREAS = 109 OCCUPANTS
TOTAL OCCUPANCY 294 OCCUPANTS
1.
2.
MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3
STAIRWAYS, SPRINKLERED, GROUP B/S = 0.2 INCHES PER OCCUPANT
OTHER EGRESS COMPONENTS, SPRINKLERED, GROUP B = 0.15 INCHES PER
OCCUPANT
SEE CODE PLANS FOR REQUIRED AND PROVIDED EXIT WIDTHS
EGRESS CONVERGANCE FROM SECTION 1005.6
WHERE THE MEANS OF EGRESS FROM STORIES ABOVE AND BELOW CONVERGE AT
AN INTERMEDIATE LEVEL, THE CAPACITY OF THE MEANS OF EGRESS FROM THE
POINT OF CONVERGENCE SHALL BE NOT LESS THAN THE LARGEST MINIMUM WIDTH
OR THE SUM OF THE REQUIRED CAPACITIES FOR THE STAIRWAYS SERVING THE TWO
ADJACENT STORIES, WHICHEVER IS LARGER.
COMMON PATH OF EGRESS TRAVEL PER TABLE 1006.2.1 =
FOR B OCCUPANCY ROOMS = SHALL NOT EXCEED 100 FEET
SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1
FOR B OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 49
FOR S OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 29
EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2
FOR B OCCUPANCY (MOST STRINGENT), WITH SPRINKLER SYSTEM = 300 FEET
CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.2
FOR B, S OCCUPANCY, WITH SPRINKLER SYSTEM = NO RATING IS REQUIRED
MINIMUM CORRIDOR WIDTH PER TABLE 1020.3 = 44 INCHES.
DEAD END CORRIDORS FROM SECTION 1020.5 EXCEPTION 2
FOR B, S OCCUPANCY, SPRINKLERRED = NO MORE THAN 50 FEET
IECC 2021 ASSEMBLY INFORMATION (A001 FOR ASSEMBLY TYPES)
BOISE, IDAHO | ADA COUNTY - ZONE 5B
SEE ELECTRICAL DRAWINGS FOR DAYLIGHT ZONE LIGHTING CONTROLS
PER TABLE C402.1.3. THE BUILDING ENVELOPE WILL MEET OR EXCEED THE BELOW:
MASS - R-11.4ci WALLS BELOW GRADE - R-7.5c.i. (CONTINUOUS INSULATION)
5'
1/
2"
11' - 2 3/4"
1402 SF = 10150
OPEN OFFICE
257 SF = 2150
HALL
532 SF = 4150
OPEN OFFICE
103 SF = 1150
OFFICE
134B
103 SF = 1150
OFFICE
134A
63 SF = 1150
FOCUS
82 SF = 1300
IDF
134 SF = 1150
OFFICE
107 SF = 1150
OFFICE
101 SF = 1150
OFFICE
100 SF = 1150
OFFICE
99 SF = 1150
OFFICE
122 SF = 1150
VESTIBULE
194 SF = 2150
LOBBY
209 SF = 2150
HALL
93 SF = 1150
OFFICE
104 SF = 1150
OFFICE
94 SF = 1150
OFFICE
359 SF = 3150
HALL
133 SF = 1150
OFFICE
281 SF = 1915
LEO-CONF
96 SF = 1150
RESTROOM
291 SF = 2015
BREAK ROOM
72 SF = 1150
WELLNESS
54 SF = 1300
STORAGE
49 SF = 1150
ELEVATOR
232 SF = 2150
EAST STAIR
152 SF = 1300
HD FILES
95 SF = 1300
DUCT-
CHASE
42 SF = 1300
STORAGE
58 SF = 1300
JANITOR
58 SF = 1300
UTILITY
230 SF = 2150
WEST STAIR
126 SF = 1150
HALL
141 SF = 1150
MEN'S
160 SF = 2150
WOMEN'S
146 SF = 1150
HALL
EX
IT
T R
AV
EL
D
IS
T.
EXIT TRAVEL DIST.
74' - 5"
EX
IT
T R
AV
EL
D
IS
T.
1"
FECFEC
13.05"
36"
4.2"
36"
4.35"
72"
4.2"
36"
13.05"
36"
154.
DIAGONAL DISTANCE140' - 2"
EXIT SEPARATION
112' - 10"
55 62 63 54
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
:2 6:
P
M \\y sv
9.
ct ag ro up .n et \u se rd at a\ be nj am in gr ab st ei n\ D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ be nj am in gr ab st ei n.
rv t
C O
D E
SH
EE
T
FI
R
ST
F
LO
O R
PL
AN
M O
R
TE
N
SO
N
G R
AB
ST
EI
N
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
GI101
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
4 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
B1 FIRST FLOOR CODE PLAN
NOTE: SEE OTHER CODE PLAN SHEETS FOR ADDITIONAL CODE REVIEW
INFORMATION
NFPA 101 2021 CODE ANALYSIS
OCCUPANCY: BUSINESS
STORIES: 3
CONSTRUCTION TYPE: II-000 SPRINKLERED
PER NFPA 220 TABLE 4.1.1 -
TYPE II-000 - BUILDING ELEMENTS REQUIRE NO RATING.
PER 39.1.1.1 - CLASSIFICATION OF HAZARD CONTENTS - ORDINARY
PER 39.2.2 - ARRANGEMENTS OF MEANS OF EGRESS IS AS FOLLOWS:
9.2.5.1 - DEAD-END CORRIDOR = 50' MAXIMUM
9.2.5.3.1 - COMMON PATH OF TRAVEL = 100' MAXIMUM
PER 39.2.6.3 - MAXIMUM TRAVEL DISTANCE TO EXITS = 300'
PER 39.3.6 - CORRIDORS - TO HAVE A MIN. 0-HOUR FIRE RESISTANCE RATING
PER TABLE 7.1.3.1 - EXIT ACCESS CORRIDORS TO BE 0 HOURS
FIRE PARTITIONS - DOORS IN THESE CORRIDORS TO HAVE A RATING OF 20 MIN.
ABA CODE ANALYSIS
F202.3 ALTERATIONS
WHERE EXISTING ELEMENTS OR SPACES ARE ALTERED, EACH ALTERED ELEMENT OR SPACE
SHALL COMPLY WITH THE APPLICABLE REQUIREMENTS OF CHAPTER 2.
F202.4 ALTERATIONS AFFECTING PRIMARY FUNCTION AREAS
PRIMARY FUNCTION AREAS ARE ALL LOCATED ON ACCESSIBLE ROUTES. RESTROOMS ON EACH
FLOOR WILL BE MADE ACCESSIBLE TO OCCUPANTS AND WILL BE INCLUDED ON ACCESSIBLE
ROUTES.
0 4' 8' 16'
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.02
.25
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
.14 .26
N scottr Text Box
BID CLARIFICATION
88888 SF= ######
ROOM NAME SPACE AREA
OCCUPANCY TAG:
NUMBER OF OCCUPANTS
OCCUPANT LOAD FACTOR
FIRE EXTINGUISHER CABINET AND
EXTINGUISHER - SEE SPECIFICATIONS
M
UL RATED FIRE DOOR AND FRAME WITH
RATING AS INDICATED
- SEE SHEET AE601
ROOM / AREA NAME
ROOM / AREA NUMBER
EXIT PATH
SURFACE MOUNTED FIRE
EXINGUISHER - SEE SPECIFICATIONS
# CODE PLAN LEGEND
EGRESS LIGHTING (EXIT SIGNS) - SEE
ELECTRICAL DRAWINGS
B / BUSINESS OCCUPANCY
S2 / STORAGE OCCUPANCY
EXIT TAG:
REQUIRED WIDTH
OCCUPANT LOAD
PROVIDED WIDTH
FEC
FE
EXISTING 1 HOUR FIRE BARRIER - SEAL
PERIMETER AND PENETRATIONS PER
DETAILS ON GI103
543 SF = 3715
LARGE MEETING
ROOM
62 SF = 1300
STORAGE
004A
173 SF = 1215
MEETING ROOM
340 SF = 2315
LARGE MEETING
ROOM
197 SF = 1415
MEETING ROOM
414 SF = 2815
LARGE MEETING
ROOM
183 SF = 1300
STORAGE
339 SF = 3150
HALL
268 SF = 2150
HALL
108 SF = 1150
SOUND
STUDIO
017B
1250 SF = 9150
MEP
159 SF = 2150
UNASSIGNED
42 SF = 1150
UNASSIGNED
37 SF = 1150
UNASSIGNED
165 SF = 2150
UNASSIGNED
125 SF = 1300
STORAGE
003A
230 SF = 2150
WEST STAIR
111 SF = 1150
HALL
65 SF = 1150
LOCKERS &
SHOWER
89 SF = 1150
MEN'S
250 SF = 2150
IT
452 SF = 4150
PRODUCTION
017D
241 SF = 1300
MULTIMEDIA
STORAGE
232 SF = 2150
EAST STAIR
117 SF = 1150
WOMEN'S
25 SF = 1300
JAN
69 SF = 1150
HALL
49 SF = 1150
ELEVATOR
35 SF = 1150
SOUND BOOTH
017C
EXIT ACCESS TRAVEL DISTANCE
77' - 8"
EXIT SEPARATION
112' - 10"
FEC FEC
6.6"
60"
4.95"
36"
4.8"
36"816.
4"
81 SF = 1150
CONTROL
DIAGONAL DISTANCE140' - 2"
FE
BID ADDITIVE #1
CODE REVIEW INFORMATION
THIS ANALYSIS BASED ON BID ADDITIVE #1 CONSTRUCTION.
GOVERNING CODES:
2021 INTERNATIONAL BUILDING CODE
2021 INTERNATIONAL EXISTING BUILDING CODE
2021 INTERNATIONAL FIRE CODE
2021 INTERNATIONAL FUEL GAS CODE
2021 INTERNATIONAL MECHANICAL CODE
2021 INTERNATIONAL PLUMBING CODE
2021 INTERNATIONAL WILDLAND-URBAN INTERFACE CODE
2021 INTERNATIONAL ENERGY CONSERVATION CODE
2021 NFPA 101 LIFE SAFETY CODE
ARCHITECTURAL BARRIERS ACT (ABA) ACCESSIBILITY STANDARDS
*SHOULD A CONFLICT EXIST BETWEEN BLM ADOPTED CODES AND STATE OR LOCAL
CODES, BLM ADOPTED CODES SHALL PREVAIL
IEBC 2021 ANALYSIS:
CLASSIFICATION OF WORK: LEVEL 2 ALTERATION
603.1 LEVEL 2 ALTERATIONS INCLUDE THE ADDITION OR ELIMINATION OF ANY DOOR OR
WINDOW, THE RECONFIGURATION OR EXTENSION OF ANY SYSTEM, OR THE
INSTALLATION OF ANY ADDITIONAL EQUIPMENT, AND SHALL APPLY WHERE THE WORK
AREA IS EQUAL TO OR LESS THAN 50 PERCENT OF THE BUILDING AREA.
603.2 LEVEL 2 ALTERATIONS SHALL COMPLY WITH PROVISIONS OF CHAPTER 7 AND 8
701.2 AN EXISTING BUILDING OR PORTION THERE OF SHALL NOT BE ALTERED SUCH
THAT THE BUILDING BECOMES LESS SAFE THAN ITS EXISTING CONDITION.
703.1 ALTERATIONS SHALL BE DONE IN A MANNER THAT MAINTAINS THE LEVEL OF FIRE
PROTECTION PROVIDED.
801.4 NEW CONSTRUCTION ELEMENTS, COMPONENTS, SYSTEMS AND SPACES SHALL
COMPLY WITH THE REQUIREMENTS OF THE INTERNATIONAL BUILDING CODE.
802.4 THE INTERIOR FINISH AND TRIM OF WALLS AND CEILINGS IN EXITS AND
CORRIDORS IN ANY WORK AREA SHALL COMPLY WITH THE REQUIREMENTS OF THE
INTERNATIONAL BUILDING CODE.
809.1 LEVEL 2 ALTERATIONS TO EXISTING BUILDINGS ARE PERMITTED WITHOUT
REQUIRING THE ENTIRE BUILDING TO COMPLY WITH THE ENERGY REQUIREMENTS OF
THE INTERNATIONAL ENERGY CONSERVATION CODE. ALTERATIONS SHALL CONFORM
TO THE ENERGY REQUIREMENTS OF TEH INTERNATIONAL ENERGY CONSERVATION
CODE AS THEY RELATE TO NEW CONSTRUCTION ONLY.
IBC 2021 ANALYSIS
OCCUPANCY CLASSIFICATION: B (BUSINESS), S-2 (STORAGE) PER SECTION 304.1
BUILDING OCCUPANCY HAS NOT BEEN ALTERED FROM EXISTING
FIRE SPRINKLER SYSTEM: PROVIDED
CONSTRUCTION TYPE: IIB PER SECTION 602.2
BUILDING HEIGHT, AREA, AND NUMBER OF STORIES: NOT ALTERED FROM EXISTING
FIRE-RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS FROM TABLE 601
FOR TYPE IIB, ALL ELEMENTS EXCEPT EXTERIOR WALLS = 0 HOURS
SECTION 602.2 TYPES I AND II
TYPES I AND II CONSTRUCTION ARE THOSES TYPES OF CONSTRUCTION IN WHICH
THE BUILDING ELEMENTS SPECIFIED IN TBALE 601 ARE OF NONCOMBUSTIBLE
MATERIALS, EXCEPT AS PERMITTED IN SECTION 603 AND ELSEWHERE IN THIS CODE.
CHAPTER 7 RATED / PROTECTED ASSEMBLIES NOT ALTERED FROM EXISTING
INTERIOR WALL AND CEILING FINISH REQUIREMENTS BY OCCUPANCY FROM TABLE
803.13
FOR GROUP B, SPRINKLERED (MOST STRINGENT):
EXIT ENCLOSURES AND EXIT PASSAGEWAYS = B
CORRIDORS & STIARWAYS = C
ROOMS AND ENCLOSED SPACES = C
OCCUPANT LOAD FACTOR FROM TABLE 1004.5 ASSIGNED TO EACH ROOM, TOTALS:
BASEMENT AREAS = 162 OCCUPANTS
FIRST FLOOR AREAS = 93 OCCUPANTS
SECOND FLOOR AREAS = 109 OCCUPANTS
TOTAL OCCUPANCY 364 OCCUPANTS
1.
2.
MINIMUM REQUIRED EGRESS WIDTH FROM SECTION 1005.3
STAIRWAYS, SPRINKLERED, GROUP B/S = 0.2 INCHES PER OCCUPANT
OTHER EGRESS COMPONENTS, SPRINKLERED, GROUP B = 0.15 INCHES PER
OCCUPANT
SEE CODE PLANS FOR REQUIRED AND PROVIDED EXIT WIDTHS
EGRESS CONVERGANCE FROM SECTION 1005.6
WHERE THE MEANS OF EGRESS FROM STORIES ABOVE AND BELOW CONVERGE AT
AN INTERMEDIATE LEVEL, THE CAPACITY OF THE MEANS OF EGRESS FROM THE
POINT OF CONVERGENCE SHALL BE NOT LESS THAN THE LARGEST MINIMUM WIDTH
OR THE SUM OF THE REQUIRED CAPACITIES FOR THE STAIRWAYS SERVING THE TWO
ADJACENT STORIES, WHICHEVER IS LARGER.
COMMON PATH OF EGRESS TRAVEL PER TABLE 1006.2.1 =
FOR B OCCUPANCY ROOMS = SHALL NOT EXCEED 100 FEET
SPACES WITH ONE EXIT OR EXIT ACCESS DOORWAY FROM TABLE 1006.2.1
FOR B OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 49
FOR S OCCUPANCY ROOM, MAXIMUM OCCUPANT LOAD = 29
EXIT ACCESS TRAVEL DISTANCE FROM TABLE 1017.2
FOR B OCCUPANCY (MOST STRINGENT), WITH SPRINKLER SYSTEM = 300 FEET
CORRIDOR FIRE-RESISTANCE RATING FROM TABLE 1020.2
FOR B, S OCCUPANCY, WITH SPRINKLER SYSTEM = NO RATING IS REQUIRED
MINIMUM CORRIDOR WIDTH PER TABLE 1020.3 = 44 INCHES.
DEAD END CORRIDORS FROM SECTION 1020.5 EXCEPTION 2
FOR B, S OCCUPANCY, SPRINKLERRED = NO MORE THAN 50 FEET
IECC 2021 ASSEMBLY INFORMATION (A001 FOR ASSEMBLY TYPES)
BOISE, IDAHO | ADA COUNTY - ZONE 5B
SEE ELECTRICAL DRAWINGS FOR DAYLIGHT ZONE LIGHTING CONTROLS
PER TABLE C402.1.3. THE BUILDING ENVELOPE WILL MEET OR EXCEED THE BELOW:
MASS - R-11.4ci WALLS BELOW GRADE - R-7.5c.i. (CONTINUOUS INSULATION)
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
:1 7:
P
M \\y sv
9.
ct ag ro up .n et \u se rd at a\ be nj am in gr ab st ei n\ D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ be nj am in gr ab st ei n.
rv t
C O
D E
SH
EE
T
BA
SE
M
EN
T
BI
D A
D D
IT
IV
E #1
M O
R
TE
N
SO
N
G R
AB
ST
EI
N
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
GI102
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
5 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
B1 BASEMENT CODE PLAN - BID ADDITIVE #1
MINIMUM NUMBER OF PLUMBING FIXTURES PER IBC TABLE 2902.1
BASED ON BUSINESS OCCUPANCY (MOST STRINGENT)
364 OCCUPANTS = 182 MALE, 182 FEMALE
THIS ANALYSIS BASED ON BID ADDITIVE #1 CONSTRUCTION
2901.1.2
THE TOTAL NUMBER OF FIXTURES SHALL BE PERMITTED TO BE BASED ON THE
REQUIRED NUMBER OF SEPARATE FACILITIES OR BASED ON THE AGGREGATE
OF ANY COMBINATION OF SINGLE-USER OR SEPARATE FACILITIES
WATER CLOSETS:
1 PER 25 FOR THE FIRST 50 AND 1 PER 50 FOR THE REMAINDER EXCEEDING 50
PER IPC 424.2, URINAL SHALL NOT BE SUBSTITUTED FOR MORE THAN 50
PERCENT OF REQUIRED WATER CLOSETS
REQUIRED: 5 MALE,5 FEMALE
PROVIDED: 4 MALE, 3 FEMALE, 4 UNISEX
LAVATORIES:
1 PER 40 FOR THE FIRST 80 AND 1 PER 80 FOR THE REMAINDER EXCEEDING 80
FOR BOTH MALE AND FEMALES
REQUIRED: 4 MALE, 4 FEMALE
PROVIDED: 2 MALE, 2 FEMALE, 4 UNISEX
DRINKING FOUNTAINS:
1 PER 100
REQUIRED: 4 TOTAL
PROVIDED: 5
SERVICE SINK:
REQUIRED: 1 TOTAL
PROVIDED: 3
0 4' 8' 16'
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.02
.25
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
.14 .26
N
BID ADDITIVE #1: INCLUDES UPDATES TO BASEMENT ROOMS INCLUDED
WITHIN INDICATED REGION. PROVIDE NEW FINSHES IN FIRST FLOOR OFFICE 129.
SEE SHEET 1NT.101.
scottr Text Box
BID CLARIFICATION
R
EF
0.19 12345678
D
C
B
A
B.1
C.1
C.2
FOCUS
IDF
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
VESTIBULE
LOBBY
HALL
110OFFICE
OFFICE
OFFICE
WEST STAIR
HALL
OFFICE
122 LEO-CONF
RESTROOM
BREAK ROOM
WELLNESS
STORAGE
WOMEN'S
MEN'S
HALL
UTILITY
JANITOR
HD FILES
DUCT-
CHASE
STORAGE
EAST STAIR
ELEVATOR
HALL
WORK/MAIL 131
MEDIUM
CONFERENCE
HUDDLE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
OFFICE
ALWAYS THINK SAFETY
Project #
Sh ee t T itl e:
Date:
BLM Project #
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
D ra w n by
R ev is io ns
/1
5/
:2
AM
Q
:\L
BY
D Fe de ra l P ro je ct
F ile s\
-A ct ive P ro je ct s\
.0
NI
FC
A dm in A dd n'l
R ep ai rs
\0
Dr aw in gs
\C
AD
\0
7.
8H
-1
.d wg
A
B
C
D
2 3 4 5
Ap pr ov ed b y:
C he ck ed b y:
D es ig ne d by
Seal:
De sc rip tio n
Da te
Sheet of 67
07/14/26
070117.028
140L0622D0002
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
NA
TI
O
NA
L
IN
TE
RA
G
EN
CY
F
IR
E
CE
NT
ER
D ev el op m en t A ve
, B oi se , I
D
8)
-5
IS
SU
ED
F
O R
CO
NS
TR
UC
TI
O
N
070117.028Project No.
LBYD FEDERAL, LLC
1425 Higham Street Idaho Falls, Idaho 83402 Phone (208) 528-8718
C copyright 2022
These drawings and design intent are the sole property of LBYD FEDERAL, LLC which may not be reproduced without written permission.
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
/02 /25
BI
D
CL
AR
IF
IC
AT
IO
N
0 8'4' 16'
FIRST FLOOR ABATEMENT PLANB2
H-102
S.
B
AL
LO
CK
-D
IX
ON
A.
R
IC
O
G . T
H O
R
SO
N
S.
B
AL
LO
CK
-D
IX
ON
AB
AT
EM
EN
T
PL
AN
FI
R
ST
F
LO
O
R
GENERAL SHEET NOTES
1. BUILDING REQUIRES ASBESTOS ABATEMENT.
2. REMOVE AND DISPOSE IDENTIFIED MATERIALS PER
SPECIFICATION 28214.
3. INFORMATION IS BASED ON ACM EVALUATION TEST
RESULTS DATED 11/29/18 AND 11/12/18.
4. MATERIALS TO BE REMOVED ARE SHOWN IN THE
DEMOLITION PLANS PROVIDED FOR ARCHITECTURE,
PLUMBING, CIVIL, STRUCTURAL, MECHANICAL AND FIRE
PROTECTION MODIFICATIONS.
5. CONTRACTOR IS REQUIRED TO DEVELOP PROJECT
SPECIFIC ABATEMENT PLAN PRIOR TO THE START OF ANY
DEMOLITION ACTIVITIES. NOTE 7 IDENTIFIES KNOWN ACM
MATERIALS IN BUILDING. ADDITIONAL ACM MAY BE
PRESENT IN ALL DEMOLITION AREAS AND SHOULD BE
CONFIRMED BY CONTRACTOR.
6. IN GENERAL, ALL DRYWALL MUD HAS BEEN IDENTIFIED AS
HAVING ~3% CHRYSOTILE MATERIAL.
7. OTHER ACM CONTAINING MATERIALS HAVE BEEN
IDENTIFIED. THESE ITEMS INCLUDE:
A. BEIGE TILE W/BLACK MASTIC & YELLOW MASTIC
· 3% CHRYSOTILE IN TILE
· 5% CHRYSOTILE IN MASTIC
B. WHITE TILE W/BLACK MASTIC & TAN MASTIC
· 3% CHRYSOTILE IN TILE
· 5% CHRYSOTILE IN MASTIC
C. WHITE TILE W/BLACK & YELLOW MASTIC
· 3% CHRYSOTILE IN TILE
· 5% CHRYSOTILE IN MASTIC
LEGEND
GENERAL DEMOLITION AREA TO BE ABATED
N
ABATE ALL DRYWALL AND
JOINT COMPOUND
GENERAL SIDE OF WALL TO BE ABATED
ABATE INSIDE OF WALL IN
DEMOLITION AREA ONLY
DO NOT ABATE
CMU WALLS
ABATE ALL INTERNAL WALLS
WITHIN DEMOLITION AREA
ABATE BOTH
SIDES OF WALL
ABATE BOTH
SIDES OF WALL
BOTH SIDES OF NEW WALL DOES
NOT REQUIRE ABATEMENT
0.19 12345678
D
C
B
A
B.1
C.1
C.2
BID ADDITIVE #1
STORAGE
004A
STORAGE
SOUND
STUDIO
017B
66666666
MEP
STORAGE
003A
UNASSIGNED
UNASSIGNED
WEST STAIR
EAST STAIR
HALL
HALL
JAN
WOMEN'S
MEN'S
LOCKERS &
SHOWER
HALL
IT
PRODUCTION
017D
HALL
HALL
SOUND BOOTH
017C MULTIMEDIA
STORAGE
UNASSIGNED
UNASSIGNED
9 888 8 8 8 8
OFFICE
OFFICE
CONFERENCE
OFFICE
OFFICE
CONFERENCE
TELECOM
9 9 9
9 9 9
A.
B.
C.
D.
E.
THESE DRAWINGS ARE BASED UPON EXISTING
DRAWINGS AND SITE OBSERVATIONS. THE
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED
DURING CONSTRUCTION, INCLUDING VOIDS AND
FINISHES RESULTING FROM DEMOLITION REMOVALS.
MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL
NEW CONSTRUCTION.
SEE ABATEMENT, FIRE ALARM, FIRE PROTECTION,
PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS
AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
WHERE EXISTING FLOOR FINISHES ARE REMOVED, PREP
SLAB AND/OR UNDERLAYMENT AS REQUIRED TO
RECEIVE NEW FLOOR FINISHES NOTED.
GENERAL SHEET NOTES
EXISTING ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
XXX000
SIM
NAME
X
DEMO PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
ITEMS TO BE DEMOLISHED
ITEMS TO REMAIN
SURFACE TO BE DEMOLISHED. SEE
KEYNOTES FOR DETAILS.
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
:2 4:
P
M \\y sv
9.
ct ag ro up .n et \u se rd at a\ be nj am in gr ab st ei n\ D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ be nj am in gr ab st ei n.
rv t
BA
SE
M
EN
T D
EM
O
LI
TI
O N
PL
AN
M O
R
TE
N
SO
N
G R
AB
ST
EI
N
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
AD100
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
9 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
A1 BASEMENT DEMOLITION PLAN
0 4' 8' 16'
N
# SHEET KEYNOTES
1 DEMOLISH EXISTING STAIR AND RAILINGS IN THEIR
ENTIRETY. PATCH, REPAIR AND PREP AREA FOR NEW
FINISHES.
2 DEMOLISH EXISTING INTERIOR WALL FURRING AND ALL
ASSOCIATED ITEMS TO EXTENTS SHOWN DOWN TO
EXISTING COLUMN OR CMU WALL. PATCH AND REPAIR
EXISTING COLUMN OR CMU WALL TO REMAIN WHERE
DAMAGE OCCURS. PREPARE SURFACE FOR NEW
CONSTRUCTION. COORDINATE WITH OTHER DEMOLITION
DRAWINGS.
3 DEMOLISH EXISTING WALL AND ASSOCIATED ITEMS TO
EXTENTS SHOWN. PATCH AND REPAIR ADJACENT
EXISTING WALLS TO REMAIN WHERE DAMAGE OCCURS.
COORDINATE WITH OTHER DEMOLITION DRAWINGS
4 DEMOLISH EXISTING DOOR, FRAME AND ALL HARDWARE.
5 DEMOLISH RAISED FLOOR IN ENTIRETY DOWN TO
CONCRETE TO BE FLUSH WITH ADJACENT FLOOR IN
HALL 026. PREPARE FLOOR SURFACE FOR NEW
CONSTRUCTION.
6 DEMOLISH EXISTING CARPET FLOORING WITHIN ROOM
NOTED. REMOVE EXISTING FLOORING DOWN TO
EXISTING CONCRETE SLAB. PREP FOR NEW FLOORING.
DEMOLISHED CARPET TO PALLETIZED TO BE PICKED UP
FOR RECYCLING. SEE SPECS FOR DETAILS.
7 DEMOLISH STAIR, RAMP, AND RAILINGS IN THEIR
ENTIRETY. PATCH, REPAIR AND PREP AREA FOR NEW
FINISHES.
8 DEMOLISH EXISTING EXTERIOR WALL FURRING DOWN
TO CONCRETE FOUNDATION WALL. PATCH AND REPAIR
ANY DAMAGE. PREPARE SURFACE FOR NEW
CONSTRUCTION. COORDINATE WITH OTHER DEMOLITION
DRAWINGS.
9 REMOVE WALL PANELING, FURRING, AND ALL
ASSOCIATED ITEMS DOWN TO CMU WALL. PREPARE
WALL FOR NEW CONSTRUCTION.
10 REMOVE EXISTING DOOR FRAME, AND PREP OPENING
FOR NEW DOOR AND FRAME.
11 REMOVE EXISTING CONCRETE AS REQUIRED FOR
ELECTRICAL FLOOR BOX INSTALL. PREP FOR NEW
CONCRETE.
12 EXISTING F.E.C. TO REMAIN, PROTECT FROM DAMAGE.
13 EXISTING F.E. TO REMAIN, PROTECT FROM DAMAGE.
14 EXISTING FLOORING TO REMAIN. PROTECT FROM
DAMAGE.
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.02
.25
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
.14 .26 scottr Text Box
BID CLARIFICATION
D
C
B
A
B.1
C.1
C.2
STORAGE
004A
STORAGE
SOUND
STUDIO
017B
BID ADDITIVE #1
11111111
MEP
UNASSIGNED
UNASSIGNED
STORAGE
003A
LOCKERS &
SHOWER
HALL
HALL
IT
PRODUCTION
017D
MEN'S
WOMEN'S
JAN
HALL
HALL
EAST STAIR
WEST STAIR
UNASSIGNED
UNASSIGNED
SOUND BOOTH
017C MULTIMEDIA
STORAGE
HALL
ELEVATOR
CONTROL
OFFICE
OFFICE
CONFERENCE
OFFICE
OFFICE
CONFERENCE
TELECOM
A.
B.
C.
D.
E.
THESE DRAWINGS ARE BASED UPON EXISTING
DRAWINGS AND SITE OBSERVATIONS. THE
CONTRACTOR IS RESPONSIBLE TO FIELD VERIFY ALL
CONDITIONS AND DIMENSIONS PRIOR TO COMMENCING
WORK.
PROTECT ALL EXISTING ITEMS TO REMAIN FROM
DAMAGE. PATCH AND REPAIR ALL ITEMS DAMAGED
DURING CONSTRUCTION, INCLUDING VOIDS AND
FINISHES RESULTING FROM DEMOLITION REMOVALS.
MATCH ADJACENT EXISTING CONSTRUCTION FOR ALL
NEW CONSTRUCTION.
SEE ABATEMENT, FIRE ALARM, FIRE PROTECTION,
PLUMBING, MECHANICAL, AND ELECTRICAL DRAWINGS
AND SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
EXISTING CEILINGS AND ASSOCIATED MECHANICAL AND
ELECTRICAL ELEMENTS ARE SHOWN FOR
COORDINATION PURPOSES FOR THE NECESSARY
DISCIPLINES. VERIFY ALL ITEMS IN FIELD.
GENERAL SHEET NOTES
EXISTING ROOM NAME AND NUMBER
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
XXX000
SIM
NAME
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
ITEMS TO BE DEMOLISHED
ITEMS TO REMAIN
SURFACE TO BE DEMOLISHED. SEE
KEYNOTES FOR DETAILS.
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
:1 7:
P
M \\y sv
9.
ct ag ro up .n et \u se rd at a\ be nj am in gr ab st ei n\ D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ be nj am in gr ab st ei n.
rv t
BA
SE
M
EN
T D
EM
O
R
EF
LE
C
TE
D
C
EI
LI
N
G P
LA
N
M O
R
TE
N
SO
N
G R
AB
ST
EI
N
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
AD102
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
11 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
A1 BASEMENT DEMO REFLECTED CEILING PLAN
1 DEMOLISH EXISTING CEILING, GRIDS, SUSPENSION
SYSTEMS, AND LIGHT FIXTURES IN THEIR ENTIRETY.
SEE FIRE, PLUMBING, MECHANICAL, AND ELECTRICAL
DRAWINGS FOR OTHER WORK TO OCCUR WITHIN
ROOM.
2 EXISTING CEILING TO REMAIN. REMOVE GRID AND
TILES AS NEEDED FOR ADJACENT WALL DEMOLITION
AND CONSTRUCTION. REINSTALL GRID AND TILES
AFTER WALL CONSTRUCTION IS COMPLETED.
# SHEET KEYNOTES
0 4' 8' 16'
N # De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.02
.25
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
.14 .26 scottr Text Box
BID CLARIFICATION
WALL ASSEMBLIES
A
EXISTING EXTERIOR
CONCRETE WALL
3" MINERAL WOOL BOARD
INSULATION. R-11.4 MINIMUM
2 1/2" METAL STUDS AT
24" O.C.
5/8" TYPE 'X' GYPSUM
BOARD
EXISTING EXT WALL FURRING
B
EXISTING EXTERIOR
CONCRETE COLUMN3" MINERAL WOOL BOARD
INSULATION. R-11.4 MINIMUM
5/8" TYPE 'X' GYPSUM BOARD
EXISTING EXT COLUMN FURRING
J
SOUND BATT INSULATION
3 5/8" METAL STUDS AT 16" O.C.
5/8" TYPE 'X' GYPSUM BOARD
INTERIOR SOUND PARTITION - STC 49
L
EXISTING CONCRETE COLUMN
OR CMU WALL (SEE PLANS)
1 1/2" METAL HAT CHANNELS AT
24" O.C.
5/8" TYPE 'X' GYPSUM BOARD
INTERIOR COLUMN FURRING
5/8" TYPE 'X' GYPSUM BOARD
K
SOUND BATT INSULATION
3 5/8" METAL STUDS AT 16" O.C.
INTERIOR FURRING
5/8" TYPE 'X' GYPSUM BOARD
C
EXISTING EXTERIOR
CONCRETE WALL
2" MINERAL WOOL BOARD
INSULATION. R-7.6
MINIMUM
2 1/2" METAL STUDS AT
24" O.C.
5/8" TYPE 'X' GYPSUM
BOARD
EXISTING EXT BASEMENT WALL FURRING
3" THERMALLY
BROKEN Z-GIRT AT 24"
O.C.
3" THERMALLY BROKEN
Z-GIRT AT 24" O.C.
2" THERMALLY BROKEN
Z-GIRT AT 24" O.C.
F
INTERIOR WALL FURRING
3 5/8" METAL STUDS AT 16" O.C.
5/8" TYPE 'X' GYPSUM BOARD
EXISTING CONCRETE WALL
(SEE PLANS)
SCALE: 1" = 1'-0"
A.
B.
C.
1.
GENERAL WALL TYPE NOTES:
SEE FIRST FLOOR FINISH PLAN (SHEET INT-101)
AND MATERIALS LIST (SHEET INT-601) FOR WALL
FINISHES.
PROVIDE BLOCKING AS REQUIRED TO SECURE
WALL HUNG COMPONENTS.
EXTEND ALL COMPONENTS TO UNDERSIDE OF
DECK, UNLESS NOTED OTHERWISE.
WALL TYPE MODIFIERS:
NOT USED.
WALL TYPE LEGEND
WALL TYPE DESCRIPTION
W1
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
:0 1:
A
M \\y sv
9.
ct ag ro up .n et \u se rd at a\ be nj am in gr ab st ei n\ D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ be nj am in gr ab st ei n.
rv t
LE
G
EN
D
, N O
TE
S, A N
D W
AL
L
TY
PE
S M O
R
TE
N
SO
N
G R
AB
ST
EI
N
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
AE001
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
13 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.02
.25
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
.14 .26 scottr Text Box
BID CLARIFICATION
C
B
A
B.1
C.1
C.2
021-1
1-
LARGE MEETING
ROOM
4-
4-
STORAGE
004A MEETING ROOM
LARGE MEETING
ROOM
MEETING ROOM
LARGE MEETING
ROOM
STORAGE
HALL
HALL
BID ADDITIVE #1
SOUND
STUDIO
017B
MEP
UNASSIGNED
UNASSIGNED
UNASSIGNED
UNASSIGNED
STORAGE
003A
WEST STAIR
HALL
LOCKERS &
SHOWER
MEN'S
IT
PRODUCTION
017D
MULTIMEDIA
STORAGE
EAST STAIR
WOMEN'S
JAN
L
J
J J
L
L L
C
CCCCCC
C
004A
L
L
L
L
L
L
L
L
LL
L
L L
C
L
L L
L L
C CC
L
L L
C CC
AE504
B2
ASSEMBLY TYPE (SEE ASSEMBLIES SHEET)
ASSEMBLY MODIFIER, PER TYPE
ROOM NAME AND NUMBER
WINDOW TYPE (SEE A600s)
KEYNOTE
DRAWING NUMBER
SHEET WHERE DRAWN
DOOR NUMBER (SEE SHEET A601)
DIMENSION TO FACE OF FRAMING
DIMENSION TO GRID LINE
1-
XXX000
SIM
X
XX
NAME
X
X
PLAN LEGEND
DIRECTION OF VIEW, IF APPLICABLE
DIMENSION TO CENTER LINE
CL
NEW CONCRETE PATCH
A.
B.
C.
D.
E.
F.
G.
CONTRACTOR TO FIELD VERIFY ALL EXISTING
CONDITIONS
REFER TO CODE PLANS FOR LOCATIONS OF ANY
RATED DOORS AND ASSEMBLIES
FOR ANY WALLS NOT LABELLED, USE TYPE MOST
CONSISTENT WITH SIMILAR
APPLICATIONS/LOCATIONS.
ALL STUD WALLS TO HAVE 5" STUD RETURN AT
DOORS BETWEEN STUD OPENINGS TO
PERPENDICULAR WALL AT HINGE SIDE OF DOOR.
SEE ENLARGED PLANS FOR WALL TYPES, TAGS
DIMENSIONS, AND ADDITIONAL INFORMATION FOR
AREAS SHOWN IN CALLOUTS.
ELECTRICAL REQUIREMENTS TO BE COORDINATED
WITH FURNITURE VENDOR.
SEE ABATEMENT, FIRE ALARM, FIRE PROTECTION,
PLUMBING, MECHANICAL, AND ELECTRICAL
DRAWINGS AND SPECIFICATIONS FOR ADDITIONAL
REQUIREMENTS.
GENERAL SHEET NOTES
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
:1 7:
P
M \\y sv
9.
ct ag ro up .n et \u se rd at a\ be nj am in gr ab st ei n\ D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ be nj am in gr ab st ei n.
rv t
BA
SE
M
EN
T
FL
O O
R P
LA
N
M O
R
TE
N
SO
N
G R
AB
ST
EI
N
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
AE100
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
14 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
A1 BASEMENT FLOOR PLAN
0 4' 8' 16'
N
# SHEET KEYNOTES
1 EXISTING F.E.C. TO REMAIN, PROTECT FROM
DAMAGE.
2 EXISTING F.E. TO REMAIN. PROTECT FROM
DAMAGE.
3 PATCH AND REPAIR EXISTING CMU WALL WHERE
STAIR & RAILING WERE REMOVED. PAINT TO
MATCH ADJACENT WALL SURFACE
4 EXISTING OPENING IN EXTERIOR WALL FROM
PRIOR CONSTRUCTION PROJECT. INFILL OPENING
WITH MINIMUM R-12 MINERAL WOOL INSULATION.
5 PATCH CONCRETE SLAB ON GRADE AFTER
ELECTRICAL FLOOR BOX INSTALLATION. MATCH
EXISTING SLAB THICKNESS.
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.02
.25
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
.14 .26 scottr Text Box
BID CLARIFICATION
C
B
A
B.1
C.1
C.2
LARGE MEETING
ROOM
STORAGE
LARGE MEETING
ROOM
MEETING ROOM
LARGE MEETING
ROOM
MEETING ROOM
STORAGE
004A
SOUND
STUDIO
017B
BID ADDITIVE #1
WEST STAIR
UNASSIGNED
STORAGE
003A
MEP
UNASSIGNED
UNASSIGNED
UNASSIGNED
HALL
JAN
WOMEN'S
MEN'S
LOCKERS &
SHOWER
HALL
HALL
IT
PRODUCTION
017D
MULTIMEDIA
STORAGE
EAST STAIR
HALL
HALL
ACT
8' - 6"
ACT
7' - 6"
ACT
7' - 6"
ACT
7' - 6"
ACT
7' - 6"
ACT
7' - 6"
ACT
7' - 6"
ACT
7' - 6"
CEILING MATERIAL
CEILING HEIGHT
ADDITIONAL NOTES
EXISTING CEILING
EXISTING 2X4 CEILING
GYP
GYPSUM BOARD
CEILING - PAINT
EXP
EXPOSED STRUCTURE
AND DECK - PAINT
NOTES
ACT
0'-0 0/0"
REFLECTED CEILING LEGEND
LIGHTING -
SEE ELECTRICAL
HVAC
REGISTERS -
SEE
MECHANICAL
CEILING HEIGHT
VAR VARIES
CEILING GENERAL NOTES
A. SPACE ABOVE CEILINGS WILL BE USED FOR PLENUM
AIR RETURN. ALL MATERIALS IN THIS SPACE SHALL
BE NONCOMBUSTIBLE.
EX
EXISTING
ADDITIONAL NOTES
1. PROVIDE NEW CEILING GRID AND TILE IN THIS AREA,
CONTINUOUS WITH EXISTING CEILING.
MATCH EXISTING CEILING HEIGHT.
2. EXISTING CEILING TO REMAIN. REINSTALL ALL
CEILING GRID AND TILES REMOVED FOR DEMOLITION
OR CONSTRUCTION. REPLACE ANY CEILING GRID OR
TILES DAMAGED BY CONSTRUCTION ACTIVITIES.
ACT
2X4 ACOUSTICAL
LAY-IN CEILING
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
:1 7:
P
M \\y sv
9.
ct ag ro up .n et \u se rd at a\ be nj am in gr ab st ei n\ D oc um en ts
R ev itL oc al
Te m p\
LB
YD
BL
M
_T O
_a rc h2
4_ be nj am in gr ab st ei n.
rv t
BA
SE
M
EN
T R
EF
LE
C
TE
D C
EI
LI
N G
P
LA
N
M O
R
TE
N
SO
N
G R
AB
ST
EI
N
M O
R
TE
N
SO
N
SJ
BD
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
AE103
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
16 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
A1 BASEMENT REFLECTED CEILING PLAN
0 4' 8' 16'
N # De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.02
.25
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
.14 .26 scottr Text Box
BID CLARIFICATION
SMOKE DETECTOR - GENERAL (SYSTEM DETECTOR)
SMOKE DETECTOR - 1ST FLOOR ELEVATOR LOBBY
SMOKE DETECTOR - OTHER THAN 1ST FLR ELEV. LOBBY
HEAT DETECTOR - GENERAL
HEAT DETECTOR - ELEVATOR HOISTWAY *
HEAT DETECTOR - ELEVATOR CONTROLLER SPACE **
SYSTEM DUCT SMOKE DETECTOR
FIRE SPRINKLER VALVE SUPERVISORY TAMPER SWITCH*
FIRE SPRINKLER FLOW DETECTOR SWITCH*
NOTIFICATION APPLIANCE CIRCUIT FAULT
INITIATING DEVICE CIRCUIT FAULT
SIGNALING LINE CIRCUIT FAULT
SMOKE DETECTOR - ELEVATOR CONTROLLER SPACE
MANUAL PULL STATION
FACP AC POWER FAIL
FACP BATTERY CHARGER FAIL
FACP COMMUNICATION FAIL
SYSTEM INPUT
X
ZONE ALA
RM SIG
NAL I
NDIC
ATIO
N
AUDIBLE
ALA
RM SIG
NAL A
CTIVATIO
N
ZONE SUPERVISORY SIG
NAL I
NDIC
ATIO
N
AUDIBLE
SUPERVISORY SIG
NAL A
CTIVATIO
N
ZONE TROUBLE
SIG
NAL I
NDIC
ATIO
N
AUDIBLE
TROUBLE
SIG
NAL A
CTIVATIO
N
ACTIVATE ALL
AUDIBLE
D
EVIC
ES
ACTIVATE ALL
VISIBLE
D
EVIC
ES
TRANSMIT ALA
RM SIG
NAL T
O SUPERVISIN
G STATIO
N
ACTIVATE EXTERIO
R N
OTIFIC
ATIO
N D
EVIC
E AT FDC
CHANGE STATE O
F ASSOCIATED FAN U
NIT C
ONTROL R
ELA
Y
ACTIVATE PRIM
ARY ELE
VATOR R
ECALL
R
ELA
Y
ACTIVATE ALT
ERNATE ELE
VATOR R
ECALL
R
ELA
Y
TRANSMIT SUPERVISORY SIG
NAL T
O SUPERVISIN
G STATIO
N
TRANSMIT TROUBLE
SIG
NAL T
O SUPERVISIN
G STATIO
N
ACTIVATE ELE
VATOR SHUNT-TRIP C
ONTROL R
ELA
Y
ELEVATOR SHUNT-TRIP BREAKER POWER FAIL
FACP ANNUNCIATION NOTIFICATION CONTROL
SYSTEM OUTPUT
X
ACTIVATE ELE
VATOR C
AB ALA
RM LI
GHT
SMOKE DETECTOR - ELEVATOR HOISTWAY
* COORDINATE REQUIREMENTS WITH FIRE SPRINKLER CONTRACTOR
** COORDINATE TEMPERATURE RATINGS/SETTINGS WITH FIRE SPRINKLER CONTRACTOR
*** COORDINATE REQUIREMENTS WITH MECHANICAL/PLUMBING CONTRACTOR
NOTE: OPERATIONAL FUNCTIONS ARE ASSUMED EXISTING. FIRE ALARM CONTRACTOR SHALL FIELD VERIFY EXISTING PROGRAMMING AND MAKE MODIFICATIONS AS REQUIRED TO FACILITATE TENANT IMPROVEMENTS.
X X X X X X X X X X X X X X X X
X X X X X X X X X
X X X X X X X X X
X X X X X X X X X
X X
X X X X X X X X X X
X X
X X
X X X X X X X X X
X
X X X X X X X X X X X X X X X X X X
ELEVATOR SUMP PUMP MONITOR MODULE*** X X X
FIRE ALARM CODE SUMMARY
1.
2.
3.
4.
EXISTING GROUP B OCCUPANCY
EXISTING MULTI-STORY BUILDING - 1 STORY BELOW
GROUND, 2 STORIES ABOVE GROUND (SECOND STORY NOT
IN SCOPE).
NO GAS-FIRED EQUIPMENT CONTAINED WITHIN BUILDING
ENVELOPE.
CONSTRUCTION:
TYPE II-B (TABLE 601 OF THE IBC)
REFERENCED CODES (INCLUDES ALL LOCAL ADOPTED
AMENDMENTS):
INTERNATIONAL BUILDING CODE (IBC) 2021 EDITION
INTERNATIONAL FIRE CODE (IFC) 2021 EDITION
NFPA 101 LIFE SAFETY CODE 2021 EDITION
STANDARD FOR THE INSTALLATION OF SPRINKLER
SYSTEMS - (NFPA 13) 2022 EDITION
NATIONAL ELECTRICAL CODE (NFPA 70) 2020 EDITION
NATIONAL FIRE ALARM AND SIGNALING CODE (NFPA 72) 2022
EDITION
INTERNATIONAL MECHANICAL CODE (IMC) 2021EDITION
SAFETY CODE FOR ELEVATORS AND ESCALATORS (ASME
A17.1) 2019 EDITION
SYSTEM SCOPE:
EXISTING ADDRESSABLE FIRE ALARM SYSTEM WITH
AUTOMATIC NON-REQUIRED DETECTION COVERAGE IN ALL
EGRESS CORRIDORS AND COMMON AREAS.
EXISTING STANDARD AUDIBLE/VISIBLE NOTIFICATION
THROUGHOUT ALL COMMON AREAS.
EXISTING MONITORING OF AUTOMATIC SPRINKLER SYSTEM.
EXISTING PHASE I EMERGENCY RECALL OF ELEVATOR.
EXISTING HVAC SUPPLY AND RETURN DUCT SMOKE
DETECTION MONITORING FOR FAN UNITS OVER 2,000 CFM.
MODIFICATIONS TO SYSTEM AS REQUIRED TO FACILITATE
BASEMENT AND FIRST FLOOR TENANT IMPROVEMENTS.
GENERAL NOTES - FIRE ALARM
A.
B.
C.
D.
E.
F.
G.
COMPLY WITH LATEST ADOPTED EDITION OF THE
INTERNATIONAL BUILDING CODE (IBC), INTERNATIONAL FIRE
CODE (IFC), FIRE ALARM AND SIGNALING CODE (NFPA 72)
AND NATIONAL ELECTRICAL CODE (NFPA 70) INCLUDING ANY
LOCAL AMENDMENTS. ALL REFERENCES TO CODES AND
STANDARDS SHALL BE AS NOTED IN THE FIRE ALARM CODE
SUMMARY.
ALL FIRE ALARM CABLE SHALL BE INSTALLED IN MINIMUM
3/4" CONDUIT PAINTED RED IN COLOR AND CONCEALED
WITHIN NON-ACCESSIBLE WALLS OR ABOVE HARD-LID
CEILINGS. FIRE ALARM CABLE SHALL BE PERMITTED TO BE
FREE RUN VIA A DEDICATED J-HOOK SYSTEM WHEN
LOCATED IN ACCESSIBLE SPACES OR ABOVE ACCESSIBLE
CEILINGS SUCH AS LAY-IN ACT. SURFACE MOUNTED
CONDUIT SHALL BE ALLOWED IN UNFINISHED MECHANICAL
AREAS.
ALL FIRE ALARM DEVICES SHALL BE MOUNTED TO A STEEL
BACKBOX OR ELECTRICAL BOX. SURFACE MOUNT
LOCATIONS SHALL INCLUDE A FACTORY MATCHED BOX
SPECIFIC TO THE DEVICE.
REMOTE POWER SUPPLIES (NAC PANELS) SHALL BE
PROVIDED IN SUFFICIENT QUANTITIES AND SHALL BE
DETERMINED BY THE CONTRACTOR'S FINAL SHOP DRAWING
DESIGN. PANEL LOCATIONS NOTED ON THESE DRAWINGS
MERELY INDICATE ACCEPTABLE LOCATIONS.
CONTRACTOR SHALL COORDINATE WITH GOVERNMENT
UPON SUBSTANTIAL COMPLETION TO PROVIDE CONNECTION
TO REMOTE SUPERVISING STATION AS APPROVED BY THE
GOVERNMENT.
CONTRACTOR SHALL COORDINATE WITH THE CONTRACTING
OFFICER BEFORE PROGRAMMING FINAL DEVICE
DESCRIPTIONS IN SYSTEM MEMORY. OBTAIN APPROVAL
PRIOR TO FINAL COMPLETION.
DEVICES SHOWN HALF-TONE ARE EXISTING TO REMAIN.
NEW DEVICES SHALL MATCH EXISTING MAKE AND
MANUFACTURER.
FIRE ALARM LEGEND SYMBOLS APPLY ONLY
WHEN USED ON DRAWINGS
VISUAL NOTIFICATION DEVICE
(# INDICATES CANDELA RATING)
COMBINATION AUDIO & VISUAL NOTIFICATION DEVICE
(# INDICATES CANDELA RATING)
ADDRESSABLE MANUAL PULL STATION
ADDRESSABLE SYSTEM SMOKE DETECTOR
ADDRESSABLE SYSTEM HEAT DETECTOR
CONNECTION TO TAMPER SWITCH, SWITCH BY OTHERS
CONNECTION TO FLOW SWITCH, SWITCH BY OTHERS
CONNECTION TO PRESSURE SWITCH, SWITCH BY
OTHERS
DUCT SMOKE DETECTOR WITH RELAY CONTROL/OUTPUT
AND FAN UNIT SHUTDOWN INTERFACE
RA: RETURN AIR
SA: SUPPLY AIR
FIRE ALARM REMOTE ANNUNICATOR
FIRE ALARM CONTROL PANEL
SD
HD
TS
FS
PS
SD
FARA
FACP
FIRE ALARM CIRCUIT EXTENDER PANELNAC
SYMBOL DESCRIPTION
ADDRESSABLE MODULE - CONTROL
FIRE ALARM COMMUNICATOR - LTE (CELLULAR)DACT
FIRE ALARM CONNECTION AS NOTED
FIRE ALARM RECORD DOCUMENTS STORAGE BOXDOC
F
CM
AREA OF RESCUE ASSISTANCE CALL BOXCALL
VISUAL NOTIFICATION DEVICE
(# INDICATES CANDELA RATING); CEILING MOUNTED
COMBINATION AUDIO & VISUAL NOTIFICATION DEVICE
(# INDICATES CANDELA RATING); CEILING MOUNTED
R
AREA OF RESCUE ASSISTANCE MASTER STATION
FA FIRE ALARM RELAY
BASE
ADDRESSABLE MODULE - MONITORMM
RA/SA
FIRE ALARM DEVICE LINE TYPE LEGEND
EXISTING DEVICE TO REMAIN#
SYMBOL DESCRIPTION
DEVICE TO BE REMOVED#
NEW DEVICE#
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
2:
:0
PM
\\y sv
9.
ct ag ro up
.n et
\u se rd at a\ sa w ye ra rn es on
\D oc um en ts
R ev itL oc al Te m p\
LB
YD
BL
M
_T
O
_e le c2 4_ sa w ye ra rn es on .rv t
G
EN
ER
AL
F
IR
E
AL
AR
M
SY
ST
EM
IN
FO
R
M
AT
IO
N
AR
N
ES
O
N
AR
N
ES
O
N
BI
N
G H
AM
BI
N
G H
AM
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
FA001
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
24 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
B1 FIRE ALARM OPERATIONAL MATRIX
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.2.
BI
D
AN
D
CO
DE
C
LA
RI
FI
CA
TI
ON
7.1
4.2 scottr Text Box
BID CLARIFICATION
FACP FARA
SD
SD
F
R
F F
F F
F F
F
TO OTHER ADDRESSABLE
INITIATING DEVICES
(E)120VAC/20A CIRCUIT
DEDICATED TO FIRE
ALARM SERVICE
DACT
(E) CELLULAR DIALER
W/REMOTE ANTENNA
AS REQ'D5
(E) HVAC FAN UNIT
INTERFACE
(E) SAMPLING TUBE
RTS
F
F
F
F
F
F
F
F
# FIRE ALARM RISER NOTES
1.
A.
2.
3.
4.
5.
6.
TYPICAL EXISTING SIGNALING LINE CIRCUIT
(SLC).
PROVIDE SEPERATE OR ISOLATED
CIRCUITS FOR EACH FLOOR.
TYPICAL EXISTING NOTIFICATION APPLIANCE
CIRCUIT (NAC).
EXISTING FIRE ALARM AUXILLIARY 24VDC
CIRCUIT.
EXISTING FIRE ALARM ANNUNCIATOR POWER
AND COMMUNICATIONS CIRCUIT.
EXISTING QTY (2)- TWISTED PAIR CU. POTS
LINES.
TYPICAL EXISTING REMOTE TEST/INDICATOR
CIRCUIT.
**ALL CIRCUITS AND CONDUCTORS SHALL BE IN
ACCORDANCE WITH EQUIPMENT MANUFACTURER
RECOMMENDATIONS.
NAC
(E) PHASE I ELEVATOR
RECALL CONTROLS
(E) FIRE SPRINKLER
SYSTEM MMMM
MMCM
F
SD
(E) SILENT KNIGHT
(E) SILENT KNIGHT
110 110 110
TO NEXT NOTIFICATION APPLIANCE,
END-OF-LINE DEVICE, OR CLASS A
RETURN TO FACU
FROM FACU OR PREVIOUS
NOTIFICATION APPLIANCE
CIRCUIT PERFORMANCE REQUIREMENTS IN
ACCORDANCE WITH THE APPLICABLE SECTION FOR
PATHWAY CLASS DESIGNATION (NFPA 72, CHAPTER 12)
TO NEXT INITIATING DEVICE,
OR CLASS A RETURN TO FACU
FROM FACU OR PREVIOUS
INITIATING DEVICE
CIRCUIT PERFORMANCE REQUIREMENTS IN
ACCORDANCE WITH THE APPLICABLE SECTION FOR
PATHWAY CLASS DESIGNATION (NFPA 72, CHAPTER 12)
AMFSD SD
LEVEL/ZONE 3
IMSD FHDAM
LEVEL/ZONE 2
IMSD FHDAM
LEVEL/ZONE 1
IMSD FHDAM
FACU
SLC CONFIGURATION SHALL BE IN ACCORDANCE
WITH NFPA 72 (23.6.1) AND FIGURE A.23.6.1(C)
C1 FIRE ALARM RISER DIAGRAM (TYPICAL)
D3
FIRE ALARM NFPA 72
NAC PATHWAY DESIGNATION DETAIL
C3
FIRE ALARM NFPA 72
SLC PATHWAY DESIGNATION DETAIL
B3
FIRE ALARM NFPA 72
SLC PERFORMANCE DETAIL
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
2:
:0
PM
\\y sv
9.
ct ag ro up
.n et
\u se rd at a\ sa w ye ra rn es on
\D oc um en ts
R ev itL oc al Te m p\
LB
YD
BL
M
_T
O
_e le c2 4_ sa w ye ra rn es on .rv t
FI
R
E
AL
AR
M
S
YS
TE
M
D
ET
AI
LS AR
N
ES
O N
AR
N
ES
O
N
BI
N
G H
AM
BI
N
G H
AM
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
FA002
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
25 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.2.
MM
TS
TS
TS
FS
MM
F
F
F FACPNAC
SD
F
F
F
F
F
F
F
SD
SD
SD
SD SD
SDSD
SD
SD
F
F
F F F F
F
F
F
SD
SD
SDSD
SD
SDSD
CALL
MM
MM
1.
2.
3.
4.
DEVICES WITHIN SCOPE OF WORK AREA INDICATED TO BE
REMOVED SHALL BE RETAINED FOR RELOCATION TO
ACCOMMODATE TENANT IMPROVEMENT CONSTRUCTION.
FIRE ALARM CONTRACTOR SHALL FIELD VERIFY CIRCUIT
ROUTING AND TEMPORARILY RE-ROUTE CIRCUIT(S) TO
NEAREST EXISTING DEVICE NOT WITHIN SCOPE OF WORK AREA
TO MAINTAIN OPERATIONAL STATUS OF EXISTING DEVICES TO
REMAIN ON THE ASSOCIATED CIRCUIT.
COORDINATE REMOVAL OF EXISTING CLEAN AGENT SYSTEM
CABINETS, WIRING, NITROGEN CYLINDER, AND OTHER
ASSOCIATED ABANDONED DEVICES WITH FIRE SPRINKLER
CONTRACTOR. EXISTING FIRE ALARM DEVICES SHALL BE
REMOVED COMPLETELY AND PROPERLY DISPOSED OF.
COORDINATE REMOVAL OF EXISTING CLEAN AGENT SYSTEM
CABINETS, WIRING, NITROGEN CYLINDER, AND OTHER
ASSOCIATED ABANDONED DEVICES WITH FIRE SPRINKLER
CONTRACTOR.
KEYNOTES#
0.19 12345678
D
C
B
A
B.1
C.1
C.2
1 2
1 2
1 2
(E) SEWAGE
PUMP STATION
MONITOR
MODULE
(E) FIRE
SPRINKLER
SUPERVISORY
DEVICES
(E) SK
(E) SK
BID ADDITIVE #1
(E) ELEVATOR
SUMP PUMP
MONITOR
MODULE1 21 21 21 2
1 2
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
2:
:1
PM
\\y sv
9.
ct ag ro up
.n et
\u se rd at a\ sa w ye ra rn es on
\D oc um en ts
R ev itL oc al Te m p\
LB
YD
BL
M
_T
O
_e le c2 4_ sa w ye ra rn es on .rv t
BA
SE
M
EN
T
FI
R E
AL
AR
M D
EM
O
LI
TI
O N
P
LA
N
AR
N
ES
O
N
AR
N
ES
O
N
BI
N
G H
AM
BI
N
G H
AM
N
IF
C
-A
D M
IN
IS
TR
AT
IO
N
R
EP
AI
R
S
FY
G
AO
A
S D ev el op m en t A ve , B oi se
, I D
140L0622D002
070117.028
12.2.2025
FAD100
N
AT
IO
N
AL
IN
TE
R
AG
EN
C Y
FI
R
E C
EN
TE
R
26 67
IS
SU
ED
F
O R
C O
N
ST
R U
C
TI
O N
0 4' 8' 16'
B1 BASEMENT FIRE ALARM DEMOLITION PLAN
De sc rip tio n
Da te
IS
SU
ED
F
OR
C
ON
ST
RU
CT
IO
N
.2.
N
F
F
F
F
SD
SD
F
FA
R
A
F F F
F
FF
F F
F
SD
SD
SD
SDSD
SD
SD SD SD SD SD
F15
F
F
SD
SD
F
F
BA
SE
AM
AM
AM
AM
SD
SD
SD
SD
RTS
RTS
RTS
RTS
SD
SD
SD
1.
2.
DEVICES WITHIN SCOPE OF WORK AREA INDICATED TO BE
REMOVED SHALL BE RETAINED FOR RELOCATION TO
ACCOMMODATE TENANT IMPROVEMENT CONSTRUCTION.
FIRE ALARM CONTRACTOR SHALL FIELD VERIFY CIRCUIT
ROUTING AND TEMPORARILY RE-ROUTE CIRCUIT(S) TO
NEAREST EXISTING DEVICE NOT WITHIN SCOPE OF WORK AREA
TO MAINTAIN OPERATIONAL STATUS OF EXISTING DEVICES TO
REMAIN ON THE ASSOCIATED CIRCUIT.
KEYNOTES#
0.19 12345678
D
C
B
A
B.1
C.1
C.2
1 2 1 2
1 2 3 4 5
D
C
B
A
Sh ee t T itl e:
D es ig ne d by
D ra w n by
C he ck ed b y:
Ap pr ov ed b y:
R ev is io ns
U ni te d
St at es D ep ar tm en t o f t he In te rio r B ur ea u of L an d
M an ag em en t
BLM Project #
Project #
Date:
ALWAYS THINK SAFETY Sheet of
7/
/2
2:
:1
PM
\\y sv
9.
ct…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .