ATTACHMENT - VOLUME 9A_Plumbing Updated 07.11.13-2.pdf
PDF 732 KB Posted
- Solicitation number
- 36C24825R0025-0001
About this file
This is a plumbing plan drawing for Zone 5 of a VA hospital/clinic facility showing the layout and specifications of plumbing fixtures, pipes, and related infrastructure on Level 1, Area D. The drawing includes detailed annotations for pipe sizes, water lines (hot, cold, and filtered water), floor cleanouts, drains, vents, and sanitary lines. Various room types are labeled including medical spaces (ECG rooms, stress labs), offices, waiting areas, corridors, and toilets.
The drawing is dated 2011-2012 with multiple CPR revisions noted. It contains professional seals and was prepared by architecture/engineering consultants for the Department of Veterans Affairs. The plan uses standard architectural scales (1/8" = 1'-0" etc.) and includes a key plan showing this section's location within the overall building layout. Several technical notes are provided regarding drain connections, vent pipes, and other plumbing specifications. The building is noted as being fully sprinklered.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FLOOR
C.O.
FLOOR C.O.
FLOOR C.O.
3" AW UP &
DN (28 FU)
3" AV UP & DN
4" VENT UP & DN
6" SAN UP & DN
6" SAN UP &
DN (141 FU)
4" VENT
UP & DN
P-528
P-528AP-528A
P-528
P-528
P-401
P-502
P-528A
P-528A
P-528A
P-528A
P-528A
P-401
P-401 P-401
P-528
P-528
P-401
P-401
P-202P-404
P-201
P-701
P-702
P-404
P-702
P-404
P-502
P-528
P-102
P-101 P-101
P-102
P-102 P-102
P-102
P-101
P-102
P-102
P-102
FLOOR C.O.
FLOOR
C.O.
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
3" SIDE OUTLET
AD TYPE A
P-102 P-528A
P-701
P-609
P-404
P-404
P-404
FLOOR
C.O.
2" W UP & DN
1 1/2" V UP
2" W UP & DN
FD-D
(TYP OF 3)
P-702
FLOOR C.O.
H-PL1.1FD5-A
H-PL1.1FD2-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H-PL1.1FD5-A
H-PL1.1FD2-A
CLOSET
1C106
CLOSET
1C104
RAD/FLOURO
1M710
CONTROL
1M710a
1 1/2" V UP & DN
STAIR
1ES01
ELEVATOR
1EE02
ELEVATOR
1EE01
ELEVATOR
1FE02
ELEVATOR
1FE01
WAIT
1M702
BIO MED OFFICE
1M204
WAITING
1G404
OFFICE (PVA)
1N404
OFFICE
(FDVA/STATE)
1N203
RECEP(FDVA/STATE)
1N201
OFFICE
1H202
OFFICE
1H204
PASSAGE
1HC02
CHIEF
NON-INVASIVE
1F203
VEST
1F201
OFFICE
(FDVA/STATE)
1N204
OFFICE (DAV)
1N403
OFFICE
1N405
PHYSICIAN
1F303
CHIEF OF
CARDIOLOGY
1M715
ECG CUBICLE
1F404
STRESS
LAB/ECHO
1F602
STRESS
LAB/ECHO
1F604
STORAGE
1F101
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
TLT
1F403
ELEC
1N601a
CORRIDOR
1FC04
CHIEF
1G403
PACEMAKER/HOLTER
MONITOR ROOM
1F307
CORRIDOR
1FC05
HAC
1F401
CORRIDOR
1FC03
Space
2C558
ECG/ECHO
READING
1F601
ECHO ROOM
1F605
CORRIDOR
1FC06
STRESS LAB
1F607
STRETCHER
ALCOVE
1FC04a
ECG CUBICLE
1F104
CORRIDOR
1FC01
OFFICE
(FDVA/STATE)
1N206
PASSAGE
1NC02
OFFICE
(FAVA/STATE)
1N205
CORRIDOR
1NC04
OFFICE (PVA)
1N406
LOCKERS MALE
1G302a
COMM
1N601b
CANTEEN RETAIL
1N601
POLICE TRAINING
ROOM
1H206
HAC
1G305
EVIDENCE STOR
1H206a
TLT & SHWR
FEMALE
1G303b
VESTIBULE
1G303
TRAINING ROOM
1G408
LOCKERS
FEMALE
1G303a
STORAGE
1G410
OFFICE(COUNTY)
1G101b
OFFICE(COUNTY)
1G101a
CO-ORDINATOR
1G406
OFFICE/ADMIN(DAV)
1N401
TLT & SHWR
MALE
1G302b
VESTIBULE
1G302
ENTRY
1GC04
SECRETARY
1G402
SERVICE OFFICER
1G401
PHYSICIAN
1F301 CARDIAC NUC
IMAGING
1F309
DRESS
1M704
PACS OFFICE
1M406
ADPAC OFFICE
1M404
DRESS
1M714
RAD/FLOURO
1M148
CHEST RM
1M206
CONTROL
1M206a
TLT
1M304
TLT
1M302
CORRIDOR
1MC03
WORK
1F808a
STAFF TLT
1F402
ECG ROOM
1F106
RADIOLOGY
LOCKERS AND
TOILETS
1M303
PASSAGE
1MC04
CONFERENCE
1M718
COMM
1M403
EMPLOYEE
BIO-SAFETY
1M307
ELEC
1M307a
ELEVATOR
LOBBY
1F716
CORRIDOR
1FC07
Space
2C933
TECH WORK
1M210
SOILED HOLD
1M306
RF TLT
1M706
RF TLT
1M712
PATIENT REP
1F804
ELEC
1F802
SECRETARY
1M717
OFFICE (VFW)
1N202
OFFICE/RECEP(PVA)
1N402
CORRIDOR
1GC01
PATIENT REP
1F806
PATIENT
STORAGE
1F716a
ELEV LOBBY
1GC02
WAITING/LOUNGE
1G101
COFFEE SHOP
1F808
CORRIDOR
1HC09
CORRIDOR
1MC08
ELEVATOR
1FE03
CHIEF TECH
OFFICE
1M402
PUBLIC TLT
1F808b
3/4" FW
1/2" CW
1/2" HW
3/4" 3/4"
3/4" 1/2" HW
1/2" FW
1/2"
1/2"
1"
HW & CW UP
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
CW UP
CW & HW UP
FLOOR C.O.
WALL C.O.
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
P-528A
H-PL4.001
H-PL4.001
H-PL1.1FE2-A
H-PL1.1FD5-A
H-PL1.1FE2-A
H-PL1.1FD5-A
H -P
L
.1 F
D
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
H -P
L
.1 F
D
-A
H -P
L
.1 F
E
-A
H -P
L
.1 F
E
P-811
1.2
C
D
E
F
G
D.9
35.2
D.7
F.4
E.4
C.7
32333435 A7
C.81
C.91
32.532.7
33.6
P-811
P-811
P-811 P-811
P-811
FD-C
FD-C
P-528
1 1/2"
2"FD-C WITH
FUNNEL
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
AREA D, ZONE 5
C1
D3
D4
E2
A2 A3
B1 B2
D2
D5 D6
E1 E3
D1
1. 1/2" SAN UP.
2. 1/2" HW FROM SINK TO DISHWASHER. 1 1/2" DRAIN
FROM DISHWASHER TO SINK TAILPIECE.
3. NOTE NOT USED.
4. REFER TO KITCHEN CONSULTANT HQ-F SERIES
DRAWINGS FOR DRAIN LOCATIONS.
5. 1/2" CW FROM TRAP PRIMER TO FD-C.
6. 1 1/2" VENT FROM BELOW CONNECTION TO VENT
FROM URINAL P-201.
7. 1 1/2" VENT FROM BELOW CONNECTION TO VENT
FROM WATER CLOSET P-101.
8. EXTEND 1 1/2" SANITARY DRAIN FROM RELOCATED
P-528 SINK AND CONNECT TO EXISTING 2" VERTICAL
SANITARY DRAIN THAT CONTINUES DOWN THRU FLOOR.
9. PROVIDE CW, HW, VENT AND DRAIN STUB OUT FOR
FUTURE P-528A IN-COUNTER SINK INSTALLATION.
10. 1-1/2" VENT UP IN WALL TO INTERSTITIAL SPACE.
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
01 AND 02
4322Dwg. ofGO/PPG
ZONE 5 PLUMBING PLAN
BID ALTERNATE NO. 3
HOSPITAL/CLINIC LEVEL 1, AREA D,
H-PL1.1FD5-A
No. Description Date
1 CPR 078 05-12-11
2 CPR 128 08/04/11
3 CPR 160 10/14/11
4 CPR 236 03/09/12
5 CPR 272 04/30/12
File details come from the government source that posted it. Updated .