ATTACHMENT - RFI 61.pdf
PDF 1 MB Posted
- Solicitation number
- 36C24825R0025-0001
About this file
These are architectural floor plan drawings showing the Level 1 layout for Areas D (Zones 4 and 5) and Area E (Zone 2) of a new VA Medical Center hospital facility in Orlando, Florida (Project #673-950). The drawings detail room layouts, dimensions, partition types, doors, windows and other architectural elements for clinical and hospital spaces including emergency department areas, imaging rooms (MRI, CT), exam rooms, offices, waiting areas, and support spaces. Key features shown include lead-shielded walls for imaging rooms, RF shielding for MRI rooms, expansion joints, and various partition wall types. The drawings contain extensive notes regarding architectural symbols, abbreviations, dimension standards, and references to other related drawings. Multiple revisions are indicated between 2011-2013 through various Change Request Proposals (CRPs). The drawings are marked as "Building is Fully Sprinklered" and include key plans showing the location of these areas within the overall building layout.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
A. SEE SHEET G-011 FOR GENERAL ABBREVIATIONS AND
ARCHITECTURAL SYMBOLS.
B. REFER TO SHEETS H-LS SERIES FOR LIFE SAFETY PLANS
C. ALL INTERIOR PARTITIONS ARE TYPE 27 U.O.N.
SEE SHEET H-AE5.600 SERIES FOR PARTITION TYPES
D.
SEE SHEETS H-AE4.301 FOR ENLARGED PLANS - TYPICAL
ROOMS.
E.
REFER TO EQUIPMENT PLAN SHEETS H-QH4.000 SERIES
FOR ADDITIONAL DIMENSIONS AND INFORMATION.
G.
REFER TO SHEET H-AE6.000 SERIES FOR DOOR, FRAME AND
BORROWED LITE SCHEDULES AND DETAILS
H.
DIMENSIONS ARE TO COLUMN GRID, FACE OF MASONRY
OR CONCERETE OR FACE OF METAL STUD U.O.N.
DIMENSIONS NOTED AS "CLEAR" ARE FINISH FACE TO
FINISH FACE INCLUDING ALL FINISHES SUCH AS TILE,
WALL PANELS, ETC.
F.
REFER TO SHEET H-QH6.101 FOR NON-MEDICAL
EQUIPMENT LIST. REFER TO H-QH6.102 FOR TYPICAL
MOUNTING HEIGHTS AND TOILET INFORMATION.
I.
SEE H-AE6.4 SERIES FOR WINDOW AND LOUVER TYPES.
J.
REFER TO PLUMBING PANS, H-MP1 SERIES, FOR FLOOR
DRAIN LOCATIONS
K.
REFER TO SHEET H-AE5.210 FOR TYPICAL EXPANSION
JOINT DETAILS.
L.
REFER TO SHEET H-AE5.201 THRU H-AE5.302 FOR TYPICAL
PLAN DETAILS.
REFER TO 1/16" AREA PLANS FOR INTERSTITIAL SPACE
PLANS AND LEVEL 6 OVERALL ROOF PLANS.
M.
KEY NOTE LEGEND
H-AE3.246
H-AE2.362 1
ABV
W5
ABV
W5
H-AE3.334
/2
2' - 6"
1EC01.1
1E204.1
H-AE5.107
/2
/2
/2
W103a
W103a
W103a
W103
W103aW103
W103
W103
W113
W113
1EC07.1
1A410.1
3738394041
3.2 2.2
D.2B.4
C
D
E
F
B
2.0
D.9
D.7
F.4
E.4
C.7
E.6
D.6
40.6 39.4 3.8 2.840.5
37.2
D.3
39.7
1A409
MEDS
1A413
NOURISH
1A408
CLEAN SUPPLY
1A412
SOILED UTILITY
1F505
PHYSICIAN
1F501
PHYSICIAN
1A609
HAC
1F208
NURSE
1E202
MRI ROOM
1E601 C.T.
1E603
CONTROL RM
1E201
COMPUTER
EQUIPMENT
1E204
MRI CONTROL
1E610
ELEC
1F206
NURSE
1F204
NURSE
1F202
NURSE
1F210
NURSE
1F212
NURSE
1F214
NURSE
1F C
.1
1FC03
1EC07
1A C
061A C
1K805
PROFESS
NON-PHYSICIAN1K804
STAFF PHYSICIAN
1K506
RSO/PHYSICIST OFFICE
1K502
READING/CONSULT
1K510
NUC MED WAIT
1K508
RECEPTION
1E203
SOILED UTILITY
1K201
SOILED HOLD
1E205
CLEAN SUPPLY
1E501
MRI WAIT
1E605 C.T. (#2)
1K803
STAFF PHYSICIAN
1E608
WHEELCHAIR &
STRETCHER WAITING
1K705
NURSE PRACTIONER
1K801
COMMON VIEWING RM
1K513
TLT
1K511
TLT
1E304
IV PREP
1E305
RECEPTION
1M206
CHEST RM
1K505a
IMAGING RM
1K503
THYROID UPTAKE
1K205
PATIENT DOSE
1K509
EXAM RM
1K203
CLEAN SUPPLY
1E401
DRESS
1E604
CLEAN SUPPLY
1M204
BIO MED OFFICE
1E306
CRASH CART
1E402
STORAGE
1E404
TLT
1E301
STRETCHER HOLD
1E403
DRESS
1A410
AMBULANCE
ENTRANCE VESTIBULE
1A610
STAFF LKRS/LOUNGE
1F503
PHYSICIAN
1A120
GYN EXAM/
TREAT
1A122
GYN EXAM/
TREAT
1A607
ON-CALL ROOM
1A608
STAFF TLT
1F203
CHIEF NON-INVASIVE
1F201
VEST
1F303
PHYSICIAN
1F301
PHYSICIAN
1A610a
CONFERENCE
1F408
ECG: CUBICLE
1F404
ECG CUBICLE
1F402
STAFF TLT
1F406
ECG CUBICLE
1A411
O2 STOR
1M702
WAIT
1AC06
CORRIDOR
1AC04
CORRIDOR
1EC07
CORRIDOR
1FC05
CORRIDOR
1K505b
IMAGING RM
1K802
STAFF PHYSICIAN
1KC06a
EQUIP
1EC06
CORRIDOR
1EC05
CORRIDOR
1EC04
CORRIDOR
1FC02
CORRIDOR
1MC02
CORRIDOR
1FC04
CORRIDOR
1KC07
CORRIDOR
1KC06
CORRIDOR
1EC02
CORRIDOR
1EC03
CORRIDOR
1KC02
CORRIDOR
1KC05
CORRIDOR
1E302
MRI CONTROL
1K505d
TECH WORK AREA
1E206
MRI ROOM
1E206a
MRI EQUIP
1A607a
BATHROOM
1K505
ENTRY
1EC01
CORRIDOR
1ES04
STAIR
1E608a
COMM
1M206a
CONTROL
1K214a
IV PREP
1K212
PET SIM UPTAKE
1K210
PET UPTAKE
1K208
UPTAKE
1K206
UPTAKE
1K202
NUC WASTE STOR
1E C
1M C
.1
1E603
1E
1.
1E601.1
1E C
.1
1E605.1
1E C
.2
1K C
1A410
1E
5.
1KC05
1K
1K506.2
1EC03
1K807.2
1K
1.
1K
1.
1M210.1
1M206
1EC05
1F C
.2
68c
68c
68cs 68c
48b
68cs
27b
27b
27b
27b
27b
27bs 27bs
27bs
27bs
27bs
34bs
36b
27b
27b
27b
48b
68c
48b27b
27b
108b
27b
27b
105b
C
LE
A R
8'
0"
CLEAR
8' - 0"
CLEAR
8' - 0"
C
LE
AR
8'
0"
CLEAR
8' - 0" 1' - 1 1/8"
CLEAR
8' - 0"
CLEAR
8' - 0"
9'
5/
8"
1'
0"
A
11' - 11 7/8"
2' - 2 3/8"
A
8' - 8 1/8" 13' - 5 1/2"
0'
1/
2"
A
14' - 2 5/8"
5' - 5 5/8" 5' - 8 1/2"
A A
CLEAR
8' - 0"
4'
3/
8"
A
7'
1/
2"
7'
/2
2'
3/
8" 6'
/4
0'
/8
3'
3/
4" 4'
3/ 8"
3'
7/
8"
A A
5'
3/
4" 0'
1/ 8"
/2
3'
1/
2"
2'
1/
2"
/8
2'
/8
A 6' - 10 1/4"
9' - 1 1/4"
H-AE1.1FD4
H-AE1.1FD1
H-AE1.1FE1
H-AE1.1FD4
1' - 3 1/8"
1' - 9 1/2" 12' - 11"
CLEAR
5' - 6"
CLEAR
8' - 0"
A
A A
CLEAR
8' - 0"
A
A
B3
3' - 6 3/4"
CLR
4' - 0"
27bs
27bs 27bs
27bs
1'
1/
8"
9' - 9 1/4"
H -A
E 1.
1F D
H -A
E 1.
1F D
C
LE
AR
8'
0"
36 36
CC
CC
8' - 3 3/4"
36bs
27bs
36bs
CLR
8' - 11 1/2"
H-AE4.311
H-AE4.311
H-AE4.311
H-AE4.312
7 15
14' - 0 3/4"
14' - 0 3/4"
3'
8"
C
LE
A R
8'
0" 9'
3/ 8"
8'
7/
8"
/8
36 36
A
A
3'
3"
3' - 7"
CLEAR
8' - 0" 1' - 3 1/8"
3'
8' - 11 1/2"
CLEAR
6' - 0" 5' - 5 3/8" 2' - 3 1/4"
8'
0"
1'
1/
8"
3' - 6 1/2"
1' - 2 1/2"
2' - 1 1/4"
2'
7/
8"
6'
/2
5'
1/
2"
C
LE
AR
8'
0"
1'
1/
8"
6'
3/
4" 9'
7/ 8"
8'
3/
4"
0'
/2
CLEAR
8' - 0" 9' - 11 1/8"
1' - 2 1/2"
A
9' - 5"
2' - 1 1/4"
3'
5/
8"
1' - 3 1/8"
1' - 3 1/8"
A 9
27b
6' - 1"
A
CLR
2' - 10 1/4"
105°
A
CLR
1' - 6"
CLR
1' - 6"
A
9' - 8 1/8"
CLR
4' - 10 1/4"
C
LR
3' - 0"
3'
7"
1' - 3 1/8"
3'
8"
A
5' -5
/8
C
LR
4' - 9"
19bs
27bs
B9B
C
LR
1'
1/
2"
B9B
B7D
B7D
B3
H-AE4.312
8'
3/
4"
FI
N
3'
FI
N
2'
0"
FIN
3' - 0 3/4"
FIN
2' - 0"
3' - 4 7/8"
1'
3"7'
/8
7'
5/
8" 7'
5/ 8"
1' - 0 1/8"
CLEAR
18' - 5 1/2"
1'
2'
3/
8"
1E
2a B7D
B3D
1E601a
1E605a
3 3
1K504
TREADMILL
3' - 9 7/8"
1K
6.
1K
1K505c
IMAGING RM
2' - 3" 48
2'
6"
2' - 3"
48b
48b
106cs
48b
H-AE4.312
H-AE5.424
H-AE5.424
A
26a
1a
66 26a
26a
1a
10a
10a
10a
26a
H-AE5.423
10a
10a
1910a
10a66
10a
1a
1a
FI
N
1'
1"
1'
0"
FI
N
1'
1"
1' - 6"
4 4
1a
68cs
MAX
1" 8
H-AE1.1FD4
H-AE1.1FD1
H-AE1.1FE1
H-AE1.1FD4
H -A
E 1.
1F D
H -A
E 1.
1F D
1E602
CONTROL RM
1E702
C.T. (ED)
1E602
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne f oo t
B
A
C
D
E
F th re e in ch es o ne f oo t
6"
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
HOSPITAL / CLINIC
01 AND 02
4322Checker
H-AE1.1FD4-A
LEVEL 1, AREA D, ZONE 4
BID ALTERNATE NO. 3
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA D, ZONE 4
D2
D5 D6
E1 E3
D1
D7
CLINIC
HOSPITAL
P-W P-E
A4
E4
W
19 FLUSH FLOOR CABLE DUCT. SEE VENDOR DOCUMENTS AND
ELEC. EP9 SERIES DWGS.
18 CONCRETE INFILL; SEE STRUCTURAL DRAWINGS FOR
LOCATION AND DEPTH. SLAB DEPRESSION SHALL BE FILLED
WITH CONCRETE TO MATCH ADJACENT FINISH AND
SECURED WITH 18" LONG #4 DOWELS @ 24" O.C., EPOXYED
TO ADJACENT CONCRETE FACE. EMBED LENGTH OF DOWEL
IS 2", LOCATED 2 1/2" BELOW TOP OF ADJACENT CONCRETE.
PROVIDE TWO (2) LAYERS OF 6 X 6 - W2.0 X W2.0 WELDED
WIRE FABRIC AS REINFORCEMENT. SEE SIMILAR DETAIL
8/H-AE5.423.
1 PNEUMATIC TUBE STATION, SEE VERTICAL CIRCULATION
SERIES DRAWINGS
2 RF SHIELDED ENCLOSURE, SEE ENLARGED PLANS &
DETAILS
3 1.58 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
4 2.38 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
5 1.98 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
6 3.00 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
7 6.00 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
8 10.00 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
9 INTERIOR WINDOW REPLACED WITH A KNOCK-OUT PANEL IN
RF WALL
10 PROVIDE LEADED GLASS IN SECOND FRAME AT THE
EXTERIOR GLAZING AND WALL SYSTEM. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
11 SLAB DEPRESSION FOR RF FLOOR SHIELDING SYSTEM. SEE
STRUCTURAL
12 MRI TRENCH SHALL BE FILLED WITH CONCRETE TO THE
LEVEL OF DEPRESSED SLAB AND SECURED NEW
CONCRETE JOINT WITH 18” LONG #4 DOWELS @24”,
EPOXYED TO BOTH TRENCH FACE. THE EMBED LENGTH OF
DOWEL IS 2” LOCATED 2.5” BELOW DEPRESSED SLAB.
PROVIDE TWO (2) LAYERS OF 6x6-W2.0x2.0 WELDED WIRE
FABRIC AS REINFORCEMENT.
13 CT TRENCH AND COVER. SEE STRUCTURAL FOR TRENCH
DIMENSIONS & 4/H-AE5.402 FOR COVER ASSEMBLY. FINAL
CONFIGURATION OF THE TRENCH AND COVER TO BE
COORDINATED WITH THE SELECTED MANUFACTURER
14 INTERIOR FLOOR DRAIN, TYPICAL. SEE PLUMBING
DRAWINGS.
15 9.00 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
16 EXISTING TRENCH TO BE CONCRETE FILLED
17 EXTEND LEAD SHIELDING TO BACK OF PRECAST
No. Description Date
1 CPR 122 09/16/2011
2 CPR 151 09/23/2011
3 CPR 180 11/17/2011
4 CPR 236 03/09/2012
5 CPR 312 07/27/2012
6 CPR 329 08/30/2012
7 CPR 382 03/15/2013
8 CPR 381 03/29/2013
UP
DN
A. SEE SHEET G-011 FOR GENERAL ABBREVIATIONS AND
ARCHITECTURAL SYMBOLS.
B. REFER TO SHEETS H-LS SERIES FOR LIFE SAFETY PLANS
C. ALL INTERIOR PARTITIONS ARE TYPE 27 U.O.N.
SEE SHEET H-AE5.600 SERIES FOR PARTITION TYPES
D.
SEE SHEETS H-AE4.301 FOR ENLARGED PLANS - TYPICAL
ROOMS.
E.
REFER TO EQUIPMENT PLAN SHEETS H-QH4.000 SERIES
FOR ADDITIONAL DIMENSIONS AND INFORMATION.
G.
REFER TO SHEET H-AE6.000 SERIES FOR DOOR, FRAME AND
BORROWED LITE SCHEDULES AND DETAILS
H.
DIMENSIONS ARE TO COLUMN GRID, FACE OF MASONRY
OR CONCERETE OR FACE OF METAL STUD U.O.N.
DIMENSIONS NOTED AS "CLEAR" ARE FINISH FACE TO
FINISH FACE INCLUDING ALL FINISHES SUCH AS TILE,
WALL PANELS, ETC.
F.
REFER TO SHEET H-QH6.101 FOR NON-MEDICAL
EQUIPMENT LIST. REFER TO H-QH6.102 FOR TYPICAL
MOUNTING HEIGHTS AND TOILET INFORMATION.
I.
SEE H-AE6.4 SERIES FOR WINDOW AND LOUVER TYPES.
J.
REFER TO PLUMBING PANS, H-MP1 SERIES, FOR FLOOR
DRAIN LOCATIONS
K.
REFER TO SHEET H-AE5.210 FOR TYPICAL EXPANSION
JOINT DETAILS.
L.
REFER TO SHEET H-AE5.201 THRU H-AE5.302 FOR TYPICAL
PLAN DETAILS.
REFER TO 1/16" AREA PLANS FOR INTERSTITIAL SPACE
PLANS AND LEVEL 6 OVERALL ROOF PLANS.
M.
KEY NOTE LEGEND
H-AE3.342
2.2
D.2 D.1
1.2 8.1
C
D
E
F
2.0 7.3
D.9
35.2
D.7
1.4
32333435
7.7
D.3
C.81
C.91
32.532.7
H-AE3.440
H-AE3.441
33.6
1A504
ED TLT FEMALE1F505
PHYSICIAN
1A124
CONSULT
1F507
PHYSICIAN
1F602
STRESS LAB/ECHO
1F604
STRESS LAB/ECHO
1F309
UNASSIGNED
1F307
PACEMAKER/HOLTER
MONITOR ROOM
1F607
STRESS LAB
1F106
ECG ROOM
1G304
RETAIL STORAGE
1N601b
COMM
1N601a
ELEC
1H203
OFFICE
1H201
CLERICAL
1H204
OFFICE
1H410
DETECTIVE OFFICE
1G101a
OFFICE(COUNTY)
1G101b
OFFICE(COUNTY)
1G403
CHIEF
1G401
SERVICE OFFICER
1G402
SECRETARY
1GC04
ENTRY
1G410
STORAGE
1G408
TRAINING ROOM
1N401
OFFICE/ADMIN(DAV)
1N403
OFFICE (DAV)
1N405
OFFICE
1N402
OFFICE/RECEP(PVA)
1N406
OFFICE (PVA)
1N201
RECEP(FDVA/STATE)
1N203
OFFICE (FDVA/STATE)
1N202
OFFICE (VFW)
1N204
OFFICE (FDVA/STATE)
1N206
OFFICE (FDVA/STATE)
1G302b
TLT & SHWR MALE
1F808
COFFEE SHOP
1G404
WAITING
1N404
OFFICE (PVA)
1G406
CO-ORDINATOR
1H202
OFFICE
1M715
CHIEF OF CARDIOLOGY
1M717
SECRETARY
1G304a
HAC
1F716a
PATIENT STORAGE
1F403
TLT
1F401
HAC
1F101
STORAGE
1F104
ECG CUBICLE
1F C
.1
1FC03
1HC09
1G303b
TLT & SHWR FEMALE
1G305
HAC
1H206a
EVIDENCE STOR1F605
ECHO ROOM
1F601
ECG/ECHO READING
1M210
TECH WORK
1M206
CHEST RM
1M204
BIO MED OFFICE
1M406
PACS OFFICE
1M404
ADPAC OFFICE
1M706
RF TLT
1M708
RAD/FLOURO
1M307
EMPLOYEE
BIO-SAFETY
1M403
COMM
1M303
RADIOLOGY LOCKERS
AND TOILETS
1M307a
ELEC
1M718
CONFERENCE
1A501
PHONE
1H206
POLICE TRAINING
ROOM
1A502
ED TLT MALE
1F503
PHYSICIAN
1A122
GYN EXAM/
TREAT
1A607
ON-CALL ROOM
1F203
CHIEF NON-INVASIVE
1F201
VEST
1N601
CANTEEN RETAIL
1F303
PHYSICIAN
1F301
PHYSICIAN
1F408
ECG: CUBICLE
1F404
ECG CUBICLE
1F402
STAFF TLT
1F406
ECG CUBICLE
1M704
DRESS
1M714
DRESS
1F802
ELEC
1M702
WAIT
1AC05
CORRIDOR
1FC05
CORRIDOR
1M402
CHIEF TECH OFFICE
1HC09
CORRIDOR
1G303a
LOCKERS FEMALE
1G303
VESTIBULE
1F806
PATIENT REP
1F804
PATIENT REP
1F808a
WORK
1G302
VESTIBULE
1G302a
LOCKERS MALE
1FC02
CORRIDOR
1MC02
CORRIDOR
1BC04
CORRIDOR
1G101
WAITING/LOUNGE
1FC07
CORRIDOR
1F716
ELEVATOR LOBBY
1FC03
CORRIDOR
1FC04
CORRIDOR
1FC01
CORRIDOR
1FC06
CORRIDOR
1M712
RF TLT
1MC07
CORRIDOR
1F808b
PUBLIC TLT
1N205
OFFICE (FAVA/STATE)
1M206a
CONTROL
1MC03
CORRIDOR
1MC04
PASSAGE 1MC08
CORRIDOR
1FC08
CORRIDOR
1NC02
PASSAGE
1NC04
CORRIDOR
1GC01
CORRIDOR
1GC03
CORRIDOR
1HC02
PASSAGE
1GC02
ELEV LOBBY
1ES01
STAIR
1FE01
ELEVATOR
1FE02
ELEVATOR
1FE03
ELEVATOR
1FC04a
STRETCHER ALCOVE
1FC05
1MC07
1M
8.
1M
8.
1H C
1G
4.
1G
4.
1GC01
1N C
.1
1N C
1H
6.
1M
5.
1N601
1M715.2
1A
1A
1F C
1M C
1M
8.
1M
0.
1M
0.
1M
8.
1M210.1 1MC03
1M210.2
1F C
.2
1M206a
1N C
.2
1C
1FC08
1FC07
48 48
48bs
28bs
28bs 68cs
68cs
68cs
27b
36bs
68c
3959 39
68c
28cs
68c
27b
27b
68cs 68cs
68cs
68cs68cs
36b
27b
27b
36b
1EE02
ELEVATOR
1EE01
ELEVATOR
1FC01a
EQ. ALCOVE
36b
70 CC70
39bs
39bs
4bs
74 48
68c 68c 68c
68cs28bs
18 18
68cs
36b9
77c
77c
77c
77c
4bs
27bs
27bs
27bs
68c
68c
68cs
27b 27b
68cs
27b
27b
1E S
1A504.11A502.1
1G C
C
LE
AR
6'
0"
C
LE
AR
8'
0"
C
LE
A R
8'
0"
C
LE
AR
8'
0"
C
LE
AR
8'
0"
CLEAR
5' - 7"10
A
8' - 2 1/4" 2' - 2 7/8"
1'
1/
2"
7'
1/
8"
8' - 0 1/8" 1' - 0 3/4"
2'
1/
2"
5'
3/
4"
8' - 1 1/4" 4' - 10 3/8"
4'
/8
A
2'
0"
C
LE
AR
8'
0"
CLEAR
8' - 0"
6'
/8
5'
/4
2'
/4
CLEAR
8' - 0"
2'
1/
2"
19' - 2 1/8" 9'
5/
8"
10' - 6 3/4" 4' - 4"
1'
7/
8"
9' - 2 1/2" 4' - 0 3/4"
14' - 3 5/8"
A A
8' - 5"
3' - 2 1/4"
9' - 2 1/4"
6'
3/
8"
0' - 10 7/8"
5' - 11 7/8"
11' - 5 1/2"
A
0'
5/
8" 8'
/8
A
A
A
CLEAR
5' - 0"
7'
3/
8"
8' - 5 5/8"
A
3'
1/
2"
9' - 0 3/4"
1' - 2 1/2"
1' - 5 1/8"
1' - 8"
2' - 3 1/4"
1'
7" 1'
7"
13' - 10 3/8" 4' - 0 3/4"
19' - 10 3/8"
6' - 1 1/4"
11' - 5"
12' - 7 3/4"
A
H-AE1.1FD5
H-AE1.1FD2
H -A
E 1.
1F D
H -A
E 1.
1F D
135°
1'
1/
8"
8' - 9 7/8"
5' - 5" 5' - 5 5/8"
4' - 11"
/4
/4
/4
59b
1' - 6 3/4"
5'
/8
68c
41 4141
39bs
28bs
5 27b
5°
3/ 4"
A
12' - 5 1/8"
1'
H -A
E 1.
1F D
H -A
E 1.
1F D
H-AE1.1FE2
H-AE1.1FD5
CC
36bs
36bs 36bs
36b
36b
/8
7'
1/
2"
C
LE
AR
8'
0"
0'
1/
8" 5'
5/ 8"
/8
2'
7/
8"
H-AE4.305
H-AE4.305
H-AE4.305
H-AE4.312
H-AE4.321
6' - 6"
0'
/8
1'
1/
2"
1' - 1 7/8"
10' - 0 3/8" 9' - 2 1/4"
/4
2' - 6 7/8"
2'
1/
2"
27b
27b
12' - 4 3/8"
6' - 3 3/8" 12' - 1 7/8"
1' - 2 1/2"
7'
7/
8"
0'
/8
14' - 6 3/4" 6' - 8 1/2"
C
LR
4'
1/
2"
68cs
/8
/8
10' - 3 1/4"
/8
0'
/4
3/ 8"
0' - 8 1/4" 3' - 4 3/4"
7'
5/
8"
0'
/4
5'
1/
4"
1'
6"2' - 7 5/8"
2' - 2"
2'
3"
1' - 6 7/8"
3 3
4 FI
N
IS
H
1'
1/
2"
0'
/4
3/ 8"
CLEAR
13' - 2 1/4" 8' - 6 1/4" 3' - 11"
CLEAR
5' - 7" 11' - 10 7/8"
1'
1/
8" C
LE
A
R
8'
0"
3' - 11 1/8"
C
LE
A R
8'
0"
A
7' - 1 3/4" 6' - 8"
CLEAR
6' - 0"10' - 11 5/8" 3' - 4 5/8"
1'
1/
8" 1'
1/ 2"
4'
1"
C
LE
A R
8'
0" 3' - 2"
6' - 8 1/4"
/8
0'
3' - 1 1/2"
6' - 5 3/8"
C
LE
A R
8'
0"
3' - 8 3/4"
8'
3/
4"
1' - 3 1/8"
10' - 6 3/4"
3'
1/
8" 12' - 9 5/8"
0' - 10 3/4" 0' - 7 5/8"
48bs
48 48
5 5
0' - 11 1/2"
15°
6' - 4 1/4"
1' - 9 1/2"
2'
5/
8"
0' - 11 3/8"
68cs.
84cs
84cs 84
67bs.
3/8"
B3D B3D
4'
3/
8"
1'
3/
8"
1'
3/
8"
10' - 3 1/4"
3/
4"A
H-AE5.448
SIM
9' - 4 1/4"
5'
5/
8" 9'
1/ 8"
1H206b
OFFICE
1H206c
OFFICE
/4
/8
7'
1/
2"
7'
/8
3' - 8 1/4"
11' - 1 1/8" 9' - 4 3/8"
1' - 6" 1' - 6" 1' - 6"
5 5
H-AE5.434
27bs
27b
27b
H-AE5.432
27bs
H-AE4.312
1G304b
VESTIBULE
8' - 9 3/4"
27bs
27bs
A
27bs 19bs
68cs
A
1'
0"
MIN 5' - 0" CLR
1M710a
H-AE1.1FD5
H-AE1.1FD2
H -A
E 1.
1F D
H -A
E 1.
1F D
H -A
E 1.
1F D
H -A
E 1.
1F D
1M710
RAD/FLOURO
1M710a
CONTROL
1CC01
19 19
A
68bs
1C102
WAITING
1C104
CLOSET 1C106
CLOSET
1C108
HAC
1C110
TESTING RM
1C112
PASSAGE
1C112a
MAIL ROOM
1C101
RECEPTION 1CC02
CORRIDOR
1CC01
CORRIDOR
1C203
INTERVIEW
1C102.1 1CC01a
1C203.1 1C403
JOB LAB
1CC01a
CORRIDOR
8' - 4" 6' - 2"
C
LE
AR
6'
0"
CLEAR
6' - 0"
A A
C
LE
AR
6'
0"
1'
7"
6'
7"
27bs
27bs
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne f oo t
B
A
C
D
E
F th re e in ch es o ne f oo t
6"
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
HOSPITAL / CLINIC
01 AND 02
4322Checker
H-AE1.1FD5-A
LEVEL 1, AREA D, ZONE 5
BID ALTERNATES NO. 2 AND NO. 3
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
AREA D, ZONE 5
C1
D3
D4
E2
A2 A3
B1 B2
D2
D5 D6
E1 E3
D1
D7
CLINIC
HOSPITAL
P-W P-E
A4
E4
W
1 SEE ENLARGED PLAN 1/H-AE4.311 FOR TYPICAL
DIMENSIONS @ CONTROL ROOM
2 WOOD PANEL CLAD PARTITION, SEE SECTIONS
AND DETAILS FOR CONSTRUCTION
3 ACOUSTIC PANEL CLAD PARTITION, SEE
SECTIONS AND DETAILS FOR CONSTRUCTION
4 REVEAL TRIM; SIM PARTITION TYPE 9 WITH
SECOND LAYER 5/8" GYP BD FOR REVEAL
5 1.58 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
6 INTERIOR FLOOR SINK, TYPICAL. SEE PLUMBING
DRAWINGS.
7 INTERIOR FLOOR DRAIN, TYPICAL. SEE
PLUMBING DRAWINGS.
8 DEMOUNTABLE PARTITION, SEE SPEC SECTION
102219
9 2.38 mm LEAD THICKNESS. SEE SHIELDING
RECOMMENDATIONS REPORT, DIVISION 13 49 00
10 ADD 2 1/2" STUDS TO CAVITY TO ACCOMMODATE
MISSPLACEMENT OF INTERSTITIAL DECK EDGE.
SEE DETAIL 2/H-AE5.433.
18 PIN TYPE STONE ANCHOR SIZING AND
ATTACHMENT BY INSTALLER
No. Description Date
2 CPR 068 07/08/2011
3 CPR 139 09/08/2011
4 CPR 122 09/16/2011
5 CPR 191 12/08/2011
6 CPR 236 03/09/2012
7 CPR 272 04/30/2012
8 CPR 335 09/13/2012
9 CPR 374 01/31/2013
A. SEE SHEET G-011 FOR GENERAL ABBREVIATIONS AND
ARCHITECTURAL SYMBOLS.
B. REFER TO SHEETS H-LS SERIES FOR LIFE SAFETY PLANS
C. ALL INTERIOR PARTITIONS ARE TYPE 27 U.O.N.
SEE SHEET H-AE5.600 SERIES FOR PARTITION TYPES
D.
SEE SHEETS H-AE4.301 FOR ENLARGED PLANS - TYPICAL
ROOMS.
E.
REFER TO EQUIPMENT PLAN SHEETS H-QH4.000 SERIES
FOR ADDITIONAL DIMENSIONS AND INFORMATION.
G.
REFER TO SHEET H-AE6.000 SERIES FOR DOOR, FRAME AND
BORROWED LITE SCHEDULES AND DETAILS
H.
DIMENSIONS ARE TO COLUMN GRID, FACE OF MASONRY
OR CONCERETE OR FACE OF METAL STUD U.O.N.
DIMENSIONS NOTED AS "CLEAR" ARE FINISH FACE TO
FINISH FACE INCLUDING ALL FINISHES SUCH AS TILE,
WALL PANELS, ETC.
F.
REFER TO SHEET H-QH6.101 FOR NON-MEDICAL
EQUIPMENT LIST. REFER TO H-QH6.102 FOR TYPICAL
MOUNTING HEIGHTS AND TOILET INFORMATION.
I.
SEE H-AE6.4 SERIES FOR WINDOW AND LOUVER TYPES.
J.
REFER TO PLUMBING PANS, H-MP1 SERIES, FOR FLOOR
DRAIN LOCATIONS
K.
REFER TO SHEET H-AE5.210 FOR TYPICAL EXPANSION
JOINT DETAILS.
L.
REFER TO SHEET H-AE5.201 THRU H-AE5.302 FOR TYPICAL
PLAN DETAILS.
REFER TO 1/16" AREA PLANS FOR INTERSTITIAL SPACE
PLANS AND LEVEL 6 OVERALL ROOF PLANS.
M.
KEY NOTE LEGEND
1' - 10"
1' - 10"
H-AE2.383 7
H-AE3.252
H-AE3.255
W102
W102a
W136
W102a
W102
H-AE5.142
H-AE5.142
OPH
H-AE5.142
H-AE5.142
OPH
H-AE5.142
OPH
H-AE5.142
OPH
H-AE5.142
3' - 8"
3' - 11"
1' - 10" 1' - 10"
3' - 8" 5' - 10"
1' - 10"
1' - 10"
H-AE2.3837
OPH
SIM
3' - 0"
3' - 8"
1' - 10"
8'
5"
1B301.1 1BC07.3
1B403d.1
H-AE5.142
H-AE5.112
W100W100a
W14
W14
H-AE3.252
SIM
H-AE5.111
W13c
W13c
SIM
H-AE5.109
W136
1B403b.1
7.1
2.2
C.2
A.2
D.2
B.2
C.1
A.1
D.1
B.1
1.2
8.1
A
B
2.0
7.3
A.05
34.5 34.2 32.4 32.22.8
1.4
32333435
A7 6.7
7.7
B.3
34.4
A.01
35.4 31.7
A.071B303c
ARMORY WORKRM
1A721
ISOLATION
1A718
TRIAGE
1A801
OFFICE
1A803
OFFICE
1A504
ED TLT FEMALE
1A121
WAITING
1B604
HAC
1A119
TRIAGE
1A719
ANTE RM
1C102a
ELEC
1B201a
ELEC
1B201b
COMM
1B203
PROCEDURE CHECK IN
1B205
PROCEDURE CHECK IN
1B202
ADMISSIONS CHECK IN
1B204
ADMISSIONS CHECK IN
1A718.1
1A715
EXAM/TREAT
1A717
ISOLATION
1F505
PHYSICIAN
1A119.1
1A124
CONSULT
1F507
PHYSICIAN
1A115
PATIENT TLT
1BC04a
KIOSK CHECK-IN1B201
MAS WORKRM
1B403c
SECURITY SCREENING
1A501
PHONE
1A714
PATIENT TLT
1A121a
VENDING
1B603
PUBLIC TLT MALE
1B601
PUBLIC TLT FEMALE
1B505
FIRE COMMAND
1F503
PHYSICIAN
1A122
GYN EXAM/
TREAT
1AC05
CORRIDOR
1B303
VESTIBULE
1AC08
CORRIDOR
1B303a
OPERATIONS
1B303b
HOLDING
1B403
LOBBY 1B703
OFFICE OF DECEDENT
AFFAIRS
1B701
ESCORT SERVICES
1BC07
CORRIDOR1BC03
CORRIDOR
1B602
PHONE
1BC02
CORRIDOR
1B403a
RECEPTION
1BC06
CORRIDOR1B405
ELEVATOR LOBBY
1B301
VESTIBULE
1BC04
CORRIDOR
5' - 10"
C
LEAR
8' - 0"
1B403d
WAITING
1BE02
ELEVATOR
1BE04
ELEVATOR
1BE03
ELEVATOR
1BE01
ELEVATOR
1A
9.
1AC01
1A
8.
1AC07
1A
1A721.1
1A721.2
1A717.2
1B201.1
1B C
1B204.2
1B202.2
1B203.2
1B205.2
1BC03
1BC07.1
1B201a
1B
1b
1B
1BC07.2
1B201.2
1B403c.2
59bs
59bs
59bs
59bs
59bs
68c
59bs
36b
1AC08a
EQ. ALCOVE
1AC08b
EQ. ALCOVE
1BC05
CORRIDOR
36b
CC
27bs
68c 19bs19bs
68c
19 9 19bs
59bs
9 9
17 39
36bs
34bs
39bs
68c
68c 68c
28c
67bs
B9CE
101b
9 41
45c
28c
1A121A
1A717.1
1B603.1
1B603
1B601
1B601.1
1A504.11A502.1
C
LEAR
8' - 0"
C
LEAR
8' - 3 1/4"
CLEAR
5' - 6" 3' - 8 1/8"
C
LE
AR
6'
0"
A
/8
/8
6'
1/
2"
0'
5/
8"
6' - 6 3/8"
0'
3/
8"
6' - 3 7/8" 5' - 0 7/8"
7'
1/
4"
2' - 6 1/2"
1' - 10 1/4"
5'
3/
8"
0'
1/
4"
1' - 11"
1' - 7 1/8"
14' - 0 1/4"
8' - 4 7/8"
1' - 9 1/8"
5' - 5 1/8"
9' - 6 5/8"
13' - 5 1/8"
7' - 2"
CLEAR
5' - 10 5/8"
101b
24 9
54c
39bs
0' - 10 7/8"
0' - 9 1/4"
12' - 2 1/4"
0' - 1 1/4"
2' - 0"
CLEAR
8' - 1 1/2"
6' - 4 7/8"
4' - 11 3/8"
5' - 5"
1' - 1 1/2"
4' - 0"
27bs
36bs
/8
36bs
36bs
36 17 18
27b
101b101b
1B202.1
1B204.1
1B205.1
1B203.1
H-AE4.302
H-AE4.306
3'
6"
1A502
ED TLT MALE
1AC07
CORRIDOR
1AC01
CORRIDOR
H-AE5.448
H-AE5.707
H-AE4.323
H-AE5.708
1B
3c .1
9 9
101b
101c 101c
45c
101b
C
LEAR
1' - 8"
CLEAR1' - 2 1/2"
6' - 4 3/4"
10' - 6"
5' - 5" C
LEAR
1' - 8"
CLEAR1' - 2 1/2"
A
C
LR
3' - 6"
0' - 8 1/4" 7' - 8 5/8"
6' - 1 3/8" 165°
C
LEAR
2' - 5 1/2"
9A
68c
6' - 5 3/4"
A
CLR
0' - 4"
0'
7/
8"
/4
CLR
3' - 2"
A
A
E Q
E Q
E Q
C
LE
AR
5'
7/
8"
C
LE
AR
/8
A
CLEAR
5' - 0 3/8"A
59bs
A
1' - 7 5/8"
C
LEAR
4' - 9 1/2"
1' - 0 3/8"
10' - 2 3/8"
2' - 2 3/8" 8' - 5 1/8"
2' - 3 1/8" 9' - 8 5/8"
1' - 5 5/8" 0' - 9 1/2"
9' - 8 5/8" 2' - 3 1/8"
8' - 9 7/8" 2' - 3 1/8"
A
3' - 7 3/4"
9' - 1 7/8"
AC
LR
2'
7"
9' - 7 3/4"
8'
1/
4" 7'
3/ 4"
2' - 3 1/4" 7' - 10 1/4"
1/ 2"
105°
4' - 10 7/8" 10' - 3 3/4" 5' - 9 7/8"
30 59
A C
LR
0'
9"
30 A
61bs
20' - 1 1/4"
41 15
CLR
2' - 4"
C
LR
1'
6"
CLR
2' - 1"
2' - 2 3/8"
18' - 0 3/8"
1'
1/
2"
C
LE
AR
9'
1/
4"
105°
9'
3/
4"
5'
3/
8"
CLR
3' - 4"
CLR
3' - 7"
C
LR
1'
3/
4"
CLR
1' - 6"
CLR
1' - 4 1/4"
7' CLEAR MIN
A
2' - 11 7/8"
4' - 4 7/8"
CLR
1' - 1"
CLR
1' - 6"
GRID
& PTN
GRID
& PTN
H-AE1.1FE4
H-AE1.1FE3
H-AE1.1FE4
H-AE1.1FE3
H -A
E 1.
1F E
H -A
E 1.
1F E
H -A
E 1.
1F E
H -A
E 1.
1F E
101c
101b
3' - 0 1/8"
H-AE5.411
TYP
87.50'
87.50'
87.43'
87.36'
87.30'
87.43'
87.50'
87.50'
87.43'
87.36'
87.30'
87.43'
4 4
EQEQ A
1BC04
27bs
1C101
RECEPTION
1C102
WAITING
1CC02
CORRIDOR
1C202
HEARING RM
1C901
VRE SUPERVISOR
1C903
VRE OFFICE 1C905
VRE OFFICE
1C907
VRE OFFICE
1CC09b
ALCOVE 1CC09
CORRIDOR
1C902
VRE OFFICE
1C904
VRE OFFICE
1C401
VRE OFFICE
1C201
INTERVIEW
1C203
INTERVIEW
1CC01
CORRIDOR
1CC01a
CORRIDOR
1C112
PASSAGE
1C112a
MAIL ROOM
1C110
TESTING RM
1CC04
CORRIDOR
1C403
JOB LAB
1C606
CUBICLES
1C604
VRE OFFICE
1C602
CUBICLES
1CC09c
ALCOVE
1CC06
CORRIDOR
1C908
VRE OFFICE
1C102.1
99 9
GRID
& PTN
1C202.2 1C202.1
CLEAR
6' - 0"
CLEAR
6' - 0"
6'
0"
17 16
A
A
CLEAR
6' - 0"
A
A
1C203.1
1C201.1 1C203.2
1C201.2
1C
2.
1' - 8 1/2"
CLR
3' - 0 1/2"
1' - 6 7/8"
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg. of
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne f oo t
B
A
C
D
E
F th re e in ch es o ne f oo t
6"
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
HOSPITAL / CLINIC
01 AND 02
4322Checker
H-AE1.1FE2-A
LEVEL 1, AREA E, ZONE 2
BID ALTERNATE NO. 2
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA E, ZONE 2
D2
D5 D6
E1 E3
D1
D7
CLINIC
HOSPITAL
P-W P-E
A4
E4
W
1 UL LEVEL 3 BALLISTIC CONSTRUCTION @
ENCLOSING WALLS, SEE ENLARGED PLAN & DETAILS
2 CONCRETE INFILL; SEE STRUCTURAL DRAWINGS
FOR LOCATION AND DEPTH. SLAB DEPRESSION
SHALL BE FILLED WITH CONCRETE TO MATCH
ADJACENT FINISH AND SECURED WITH 18" LONG #4
DOWELS @ 24" O.C., EPOXYED TO ADJACENT
CONCRETE FACE. EMBED LENGTH OF DOWEL IS 2",
LOCATED 2 1/2" BELOW TOP OF ADJACENT
CONCRETE. PROVIDE TWO (2) LAYERS OF 6 X 6 -
W2.0 X W2.0 WELDED WIRE FABRIC AS
REINFORCEMENT. SEE SIMILAR DETAIL 8/H-AE5.423.
3 REVEAL TRIM; SIM PARTITION TYPE 9, OR AS NOTED,
WITH SECOND LAYER 5/8" GYP BD FOR REVEAL
No. Description Date
1 CPR 139 09/08/2011
2 CPR 191 12/08/2011
3 CPR 230 02/23/2012
4 CPR 285 05/21/2012
5 CPR 323 08/16/2012
6 CPR 374 01/31/2013
7 CPR 377 02/15/2013
8 CPR 380 03/01/2013
| 675-23-100 RFI RFI 61 |
| Pages from VOLUME 2C_Arch Construction Plans Updated 05.30.13-2 |
File details come from the government source that posted it. Updated .