ATTACHMENT - RFI 73.pdf
PDF 8 MB Posted
- Solicitation number
- 36C24825R0025-0001
About this file
This file contains a set of architectural/engineering drawings showing ductwork, plumbing, lighting and power plans for Level 1 of a hospital/clinic facility. The drawings appear to be part of a bid alternate package and include detailed floor plans showing HVAC ductwork layouts with CFM specifications, plumbing system layouts with pipe sizes and drainage details, lighting fixture layouts with circuit designations, and power distribution plans showing electrical device and equipment locations.
The drawings cover multiple zones (2, 4 and 5) of Area D and E of the building and contain extensive technical specifications for mechanical, electrical and plumbing systems. Key features include supply/return air ductwork sizing, medical gas piping, electrical circuit designations, lighting controls, and power connections for medical equipment. The drawings include general notes, drawing notes, and key plans showing the overall building layout. They appear to be revision sets with multiple change orders (CPRs) dated between 2011-2013. The drawings were prepared by RLF architects/engineers for what appears to be a VA medical facility project in Orlando, Florida.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CD-A
500 CFM
CD-A
500 CFM
H-CRAC-2
ER-D
100 CFM
ER-D
80 CFM
ER-D
100 CFM
CD-A
90 CFM
CD-A
210 CFM
CD-A
210 CFM
CD-A
195 CFM
CD-A
195 CFM
CD-A
385 CFM
CD-A
385 CFM
CD-A
385 CFM
CD-A
385 CFM
CD-A
185 CFM
CD-A
180 CFM
H-CRAC-1
CD-A
125 CFM
CD-A
250 CFM
CD-A
50 CFM
ER-D
150 CFM
ER-D
100 CFM
RR-A
250 CFM
CD-A
330 CFM
CD-A
150 CFM
CD-A
85 CFM
CD-A
80 CFM
CD-A
150 CFM
CD-A
100 CFM
CD-A
300 CFM
CD-A
300 CFM
CD-A
400 CFM
CD-A
170 CFM
CD-A
80 CFM
CD-A
100 CFM
CD-A
170 CFM
CD-A
50 CFMCD-A
50 CFM
CD-A
150 CFM
CD-A
175 CFM
CD-A
175 CFM
CD-A
340 CFM
CD-A
330 CFM
CD-A
475 CFM
CD-A
475 CFM
CD-A
330 CFM
CD-A
340 CFM
CD-A
330 CFM
CD-A
80 CFM
CD-A
80 CFM
CD-A
80 CFM
CD-A
80 CFM
CD-A
80 CFM
CD-A
80 CFM
CD-A
80 CFM
CD-A
170 CFM
CD-A
170 CFM
CD-A
170 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
180 CFM
CD-A
190 CFM
CD-A
190 CFM
CD-A
180 CFM
CD-A
180 CFM
CD-A
210 CFM
CD-A
210 CFM
SSR-A
410 CFM SSR-A
630 CFM
SRR-A
410 CFM
SRR-A
630 CFM
CD-A
195 CFM
CD-A
195 CFM
CD-A
150 CFM
CD-A
150 CFM
CD-A
150 CFM
CD-A
150 CFM
CD-A
80 CFM
CD-A
50 CFM
CD-A
140 CFM
CD-A
70 CFM CD-A
80 CFM
CD-A
100 CFM
CD-A
160 CFM
CD-A
90 CFM
CD-A
240 CFM
CD-A
120 CFM
CD-A
275 CFM
CD-A
160 CFM
CD-A
160 CFM
CD-A
185 CFM
CD-A
150 CFM
CD-A
175 CFM
CD-A
90 CFM
CD-A
90 CFM
CD-A
90 CFM
CD-A
90 CFM
CD-A
100 CFM
CD-A
460 CFM
CD-A
150 CFM
CD-A
145 CFM
CD-A
245 CFM
CD-A
245 CFM
ER-A
390 CFM
ER-A
340 CFM
ER-D
100 CFM
CD-A
240 CFM
RR-A
460 CFM
ER-D
100 CFM
ER-D
100 CFM
RR-A
150 CFM
RR-A
100 CFM
RR-A
330 CFM
ER-A
700 CFM RR-A
550 CFM
RR-A
100 CFM
RR-A
625 CFM
RR-A
625 CFM
RR-A
80 CFM
RR-A
80 CFM
RR-A
80 CFM
RR-A
80 CFM
RR-A
80 CFM
RR-A
80 CFM
RR-A
80 CFM
RR-A
900 CFM
RR-A
170 CFM
RR-A
350 CFM
RR-A
250 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
380 CFM
RR-A
380 CFM
RR-A
160 CFM
RR-A
345 CFM
RR-A
390 CFM
ER-D
100 CFM
RR-A
770 CFM
RR-A
90 CFM
RR-A
90 CFM
RR-A
90 CFM
RR-A
90 CFM
ER-A
390 CFM
ER-A
390 CFM
ER-A
390 CFM
ER-D
120 CFM
ER-D
80 CFM
RR-A
150 CFM
RR-A
150 CFM
RR-A
150 CFM
RR-A
100 CFM
RR-A
140 CFM
RR-A
80 CFM
RR-A
50 CFM
RR-A
90 CFM
RR-A
120 CFM
CD-A
135 CFM
RR-A
135 CFM
RR-A
90 CFM
RR-A
340 CFM
RR-A
120 CFM
RR-A
150 CFM
14"x12"
12"x10"
10"x10" 12"x10"
10"x8"
CD-A
500 CFM
CD-A
500 CFM
18"x12"
CD-A
330 CFM
CD-A
330 CFM
CD-A
340 CFM
CD-A
330 CFM
18"x12"
CD-A
330 CFM
CD-A
340 CFM
CD-A
330 CFM
18"x12"
18"x12"
10"x10"
14"x14"
14"x12"
RR-A
340 CFM
8"x8"
8"x8"
CD-A
220 CFM
CD-A
220 CFM
CD-A
220 CFM
14"x14"
14"x14"14"x16"
RR-A
550 CFM
RR-A
340 CFM
16"x14"
RR-A
80 CFM
16"x14"
14"x12"
RR-A
250 CFM
12"x14"
14"x12"
ER-D
200 CFM
10"x10"
14"x12"
ER-A
700 CFM
ER-A
700 CFM
10"x10"
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
625 CFM
RR-A
625 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
CD-A
170 CFM
CD-A
170 CFM
RR-A
140 CFM
RR-A
340 CFM
RR-A
640 CFM
RR-A
85 CFM
10"x10" 12"x12"
RR-A
200 CFM
LFD-B
260 CFM
LFD-B
260 CFM
10"ø UP
16"x14"
16"x14"
10"ø
RR-A
50 CFM
10"x10"
10"x10"
RR-A
550 CFM
ER-A
300 CFM
12x12 UP
8"x10" 6"x6"
8"x12"
10"x12"
14x12 UP
12"x12"14"x14"
14x14 UP
10"x10"
10"x8"
"x
"x
10"x10"
10"x10" 10"x10"
8"x8"
6"x10"
"x
"x
12"x12"
12"x12"
16"x14"
10"x10"
10"x8"
6"x8"
10"x8"
14x14 UP
14"x14"
8"x10"
10"x10"
10"x10"
14"x14"8"x8"
10"x8"
8"x10"
12"x12"
8"x8" 8"x10"
8"x10"
8"x10" 8"x10"
8"x12"
RR-A
150 CFM
10"x10" 8"x8"
8"x8"
8"x10"
8"x8"
10"x10"
ER-A
240 CFM
RR-A
340 CFM
RR-A
340 CFM
10"x10"
10"x10"8"x10" 8"x10"
16"x14"
6"x8"
12"x12" 12"x12"
IMAGING RM
1K505c
C.T. (ED)
1E702
C.T. (ED)
1E702
RAD/FLOURO
1M710
RR-A
100 CFM
CD-A
150 CFM
H-MH-1.1FD4
H-MH-1.1FD1
H -M
H -1
.1 F
D
H -M
H -1
.1 F
D
H-MH-1.1FE1
H-MH-1.1FD4
10"x10"
EGG ROOM
1F106
CARDIAC NUC
1F309
8"x8"
12"x12"
8"x10"
6"x10"
12"x8"
16"x10"
16"x10"
12"x12"
10"x10"
8"x10"
8"x10"
8"x10"
8"x10"
10"x8"
8"x8"
6"x10"
12"x12"
6"x8"
10"x10"
8"x8"
363738394041
D.2 1.2
C
D
E
F
G
2.0
D.9
D.7
F.4
E.4
C.7
E.6
D.6
40.6 39.4 1.440.5
37.2
39.7
ER-A
390 CFM
RR-A
770 CFM
14"x16"
12"x12"
14"x16"
H-CRAC-12
H-CRAC-13
12"x12"
8"x12"
14"x12"
H-CRAC-14
RR-A
240 CFM
10"x10"
8"x8"
CD-A
120 CFM
14"x12"
10"x10"
10"x10"
12"x12"
12"x12"
10"x10"
14"x16"
14"x12"
14"x12"
CD-B
245 CFM
CD-B
245 CFM
CD-B
50 CFM
CD-A
140 CFM
RR-A
90 CFM
16"x14"
14"x14"
12"x12"
12"x12"
CD-A
260 CFM
CD-A
270 CFM
14"x12"
CD-A
185 CFM
CD-A
185 CFM
(TYP. OF 6)
(TYP. OF 6)
8"x6"
8"x6"
CD-A
150 CFM
RR-A
100 CFM
14"x14"
CD-A
150 CFMRR-A
100 CFM
14"x14"
14"x14"
10"x10"
CD-A
150 CFMRR-A
100 CFM
CD-A
185 CFM
12"x12"
STAIR
1ES04
NURSE
1F214
ECG CUBICLE
1F404
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
PHYSICIAN
1F503
STAFF PHYSICIAN
1K802
STAFF PHYSICIAN
1K804
C.T. (#2)
1E605
PHYSICIAN
1F301
VEST
1F201
CHIEF NUC MED OFFICE
1K807
PROFESS NON-PHYSICIAN
1K805
STAFF PHYSICIAN
1K803
STRETCHER HOLD
1E301
RECEPTION
1K508
NUC MED WAIT
1K510
COMMON VIEWING RM
1K801
EQUIP
1KC06a
PASSAGE
1KC08
MRI CONTROL
1E204
CORRIDOR
1EC02
PET UPTAKE
1K210
UPTAKE
1K208
CONFERENCE
1A610a
STAFF PHYSICIAN
1K806
NURSE
1F210
NURSE
1F212
NURSE
1F204
NURSE
1F206
NURSE
1F208
CORRIDOR
1FC02
NURSE PRACTIONER
1K705
CLEAN SUPPLY
1K203
READING/CONSULT
1K502
PATIENT DOSE
1K205
THYROID UPTAKE
1K503
ENTRY
1K505
TECH WORK AREA
1K505d
CORRIDOR
1EC05
CORRIDOR
1EC03
CLEAN SUPPLY
1E604
MRI WAIT
1E501
RECEPTION
1E305
IV PREP
1E304
STORAGE
1E402
PET SIM UPTAKE
1K212
TREADMILL
1K504
CONTROL RM
1E603
UPTAKE
1K206
CORRIDOR
1KC02
BIO MED OFFICE
1M204
WAIT
1M702
CORRIDOR
1KC07
ELEC
1E610
DRESS
1E403
DRESS
1E401
CRASH CART
1E306
WHEELCHAIR & STRETCHER
WAITING
1E608
NOURISH
1A413
STAFF LKRS/LOUNGE
1A610
HAC
1A609
PHYSICIAN
1F501
NURSE
1F202
CORRIDOR
1FC05
C.T.
1E601
CORRIDOR
1EC06
CORRIDOR
1EC07
CHEST RM
1M206
ON-CALL ROOM
1A607
TLT
1K513
EXAM RM
1K509
CORRIDOR
1KC05
CORRIDOR
1KC06
STAFF TLT
1F402
CORRIDOR
1EC04
TLT
1E404
SOILED UTILITY
1A412
TLT
1K511
IV PREP
1K214a
MRI ROOM
1E202
MRI EQUIP
1E206a
NUC WASTE STOR
1K202
MRI CONTROL
1E302
IMAGING RM
1K505c
IMAGING RM
1K505a
IMAGING RM
1K505b
CORRIDOR
1MC02
SOILED HOLD
1K201
CORRIDOR
1EC01
COMM
1E608a
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950Professional Seals:
EB / RLF of04 JUNE, 2010
BUILDING IS FULLY SPRINKLERED
01 AND 02
HOSPITAL/CLINIC LEVEL 1, AREA D,
H-MH1.1FD4-A
ZONE 4 DUCTWORK PLAN
BID ALTERNATE NO. 3
PG/JI 2248
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA D, ZONE 4
D2
D5 D6
E1 E3
D1
1 QUENCH VENT FROM MRI SYSTEM TO MRI
SHIELD PENETRATION TO BE PROVIDED BY MRI
VENDOR. CONTRACTOR TO PRIVIDE
INSULATION. FOR QUENCH VENT INSIDE RF
SHIELD, SEE SPECIFICATION SECTION 230711
FOR INSULATION REQUIREMENTS.
DRAWING NOTES
2 NOT USED.
FOR CONTINUATION UP, SEE H-MH-1.1ND4A.
GENERAL NOTES
3 PROVIDE RF WAVE FILTER AT DUCT
PENETRATION THROUGH RF SHIELD. PROVIDE
ALUMINUM DUCTWORK, DIFFUSERS AND
GRILLES INSIDE RF-SHIELD. COORDINATE RF
SHIELD PENETRATION LOCATION WITH RF
SHIELD MANUFACTURER.
No. Description Date
1 CPR 098 06/17/2011
2 CPR 122 09/16/2011
3 CPR 132 10/17/2011
4 CPR 236 03/09/2012
5 CPR 353 10/25/2012
6 CPR 382 03/15/2013
7 CPR 404 07/15/2013
2 2
2 2
2 2
4 OPEN END DUCT TO FLARE TO 24X14 WITH
NON METAL MESH SCREEN (1370 CFM).
5 42x12 EXHAUST GRILLE (1370 CFM).
6 CONNECT TO GRADIENT COIL EXHAUST
SYSTEM. COORDINATE WITH MRI EQUIPMENT
MANUFACTURER FOR EXACT LOCATION.
7 DUCT MOUNTED TEMPERATURE SENSOR.
8 NOT USED.
9 PROVIDE 12X12 ACCESS DOOR AT BOTTOM OF
DUCT FOR CLEANING ACCESS.
100 CFM
CD-A
340 CFM
CD-A
340 CFM
ER-A
950 CFM
RR-A
475 CFM
ER-A
135 CFM
ER-A
135 CFM
ER-A
135 CFM
ER-A
380 CFM
CD-A
200 CFM
CD-A
180 CFM
ER-C
310 CFM
CD-A
130 CFM
CD-A
185 CFM
CD-A
185 CFM
CD-A
80 CFM
CD-A
80 CFM
CD-A
125 CFM
CD-A
140 CFM
8"x10"
10"x10"
CD-A
240 CFM
CD-A
240 CFM
CD-A
70 CFM
CD-A
70 CFM
ER-A
850 CFM
CD-A
170 CFM
RR-A
170 CFM
CD-A
140 CFM
CD-A
155 CFM
CD-A
180 CFM
CD-A
190 CFM
CD-A
190 CFM
CD-A
175 CFM
CD-A
175 CFM
CD-A
180 CFM
CD-A
180 CFM
CD-A
210 CFM
CD-A
210 CFM
CD-A
140 CFM
CD-A
110 CFM
CD-A
170 CFM
CD-A
170 CFM CD-A
100 CFM
CD-A
340 CFM
CD-A
340 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
200 CFM
CD-A
200 CFM
CD-A
180 CFM
CD-A
210 CFM
CD-A
140 CFM
CD-A
140 CFM CD-A
140 CFM
CD-A
180 CFM
CD-A
180 CFM
CD-A
180 CFM
CD-A
90 CFM
CD-A
90 CFM
CD-A
80 CFM
CD-A
80 CFM
CD-A
125 CFM
CD-A
125 CFM
CD-A
120 CFM
CD-A
120 CFM
CD-A
100 CFM
CD-A
180 CFM CD-A
110 CFM
CD-A
110 CFM
CD-A
110 CFM
CD-A
110 CFM
CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM CD-A
225 CFM
CD-A
225 CFM
CD-A
225 CFM
SSR-A
385 CFM
SSR-A
410 CFM
SRR-A
385 CFM
SRR-A
410 CFM
CD-A
150 CFM
CD-A
215 CFM
SRR-A
580 CFM SRR-A
520 CFM
SSR-A
580 CFM
SSR-A
520 CFM
CD-A
260 CFM
CD-A
90 CFM
CD-A
80 CFM
CD-A
100 CFM
CD-A
245 CFM
CD-A
130 CFM
ER-C
310 CFM
CD-A
460 CFM
CD-A
130 CFM
CD-A
230 CFM
RR-A
230 CFM
CD-A
80 CFM
RR-A
80 CFM
SRR-A
280 CFM
SSR-A
280 CFM
CD-A
80 CFM
RR-A
80 CFM
RR-A
80 CFM
CD-A
80 CFM
CD-A
140 CFMCD-A
140 CFM
RR-A
280 CFM
CD-A
300 CFM
RR-A
300 CFM
CD-A
300 CFM
CD-A
460 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
700 CFM
RR-A
110 CFM
RR-A
80 CFM
RR-A
80 CFM
RR-A
100 CFM
RR-A
110 CFM
RR-A
100 CFM
RR-A
100 CFM
RR-A
80 CFM
RR-A
80 CFM
RR-A
210 CFM
RR-A
70 CFM
RR-A
90 CFM
RR-A
90 CFM
ER-A
100 CFM
ER-A
270 CFM
ER-A
270 CFM
ER-A
160 CFM
ER-A
160 CFM
ER-A
160 CFM
ER-D
100 CFM
RR-A
340 CFM
RR-A
590 CFM
RR-A
590 CFM
RR-A
200 CFM
RR-A
215 CFM
CD-A
100 CFMCD-A
110 CFM
CD-A
110 CFM
CD-A
100 CFM
CD-A
80 CFM
CD-A
375 CFM
CD-A
375 CFM
RR-A
740 CFM
ER-D
100 CFM
CD-A
50 CFM
CD-A
160 CFM
ER-D
100 CFM
ER-D
100 CFM
ER-D
250 CFM
ER-D
170 CFM
ER-A
390 CFM
ER-A
340 CFM
ER-D
100 CFM
RR-A
100 CFM
RR-A
80 CFM
RR-A
90 CFM
RR-A
350 CFM
RR-A
350 CFM
ER-D
100 CFM
ER-D
100 CFM
CD-A
100 CFM
RR-A
380 CFM
RR-A
380 CFM
CD-A
160 CFM
RR-A
160 CFM
RR-A
110 CFM
RR-A
480 CFM
RR-A
345 CFM
RR-A
210 CFM
RR-A
210 CFM
CD-A
135 CFM
RR-A
135 CFM
CD-A
80 CFM
CD-A
100 CFM
RR-A
140 CFM
CD-A
285 CFM
CD-A
285 CFM
CD-A
110 CFM
CD-A
90 CFM
CD-A
215 CFM
CD-A
215 CFM
CD-A
235 CFM
CD-A
235 CFM
CD-A
235 CFM
CD-A
150 CFM
RR-A
700 CFM
10"x10"
10"x10"
16"x14"
CD-A
100 CFM
CD-A
325 CFM
CD-A
475 CFM
14"x12"
CD-A
215 CFM
CD-A
215 CFM
10"x10"
12"x12"
ER-D
100 CFM
ER-D
100 CFM
ER-D
230 CFM
ER-A
475 CFM
ER-A
425 CFM
ER-D
100 CFM
14"x14" 14"x14"
14"x14"
12"x12"
10"x10"
14"x14"
RR-A
590 CFMRR-A
590 CFM
CD-A
190 CFM
CD-A
190 CFM
14"x12"
10"x10"
14"x16"
CD-A
180 CFM
RR-A
50 CFM
14"x14"
10"x10"
CD-A
220 CFM
CD-A
220 CFM
14"x14"
14"x14"
14"x14"
RR-A
160 CFM
RR-A
125 CFM
RR-A
140 CFM
14"x14"
10"x8"
CD-A
100 CFM
CD-A
50 CFM
CD-A
70 CFM
12"x12"
16"x14"
16"x14"
12"x12"
6"x6" 12"x12"
RR-A
1390 CFM
RR-A
1390 CFM
RR-A
100 CFM
ER-D
100 CFM
TG-A
1000 CFM
RR-A
590 CFM RR-A
70 CFM
8"x8"
16x14 UP 16x14 UP
14"x14" 14"x10"
12"x10"
12"x10"
10"x10"
14"x14"
CD-A
75 CFM
8"x8"
12"x12" 10"x10"
12"x10"
10"x10"10"x10"
14"x14"8"x8"
8"x10"
12"x12"
8"x8" 8"x10"
8"x10"
CD-A
150 CFM
CD-A
100 CFM
14"x16"
8"x8"
16"x14"
14"x12"
8"x10"
8"x8"
12"x10"
14"x12"
14"x14"
RR-A
340 CFM
RR-A
340 CFM
10"x10" 10"x10"
10"x10"8"x10" 8"x10"
10"x10"
6"x10" 12"x10"
10"x12"
10"x10"
6"x10"
8"x8"
8"x8"
14"x8"
10"x10" 10"x10"
6"x10"
6"x10"
6"x8"
14"x12"
14"x12" 10"x12"
10"x10"
12"x12"
12"x10"
10"x8"
8"x8"
4"x8" 10"x8"
6"x8"
10"x8"
12"x10"8"x10"
4"x10"
6"x10"
12"x12"
8"x10"8"x10"
16"x12"
12"x10"
8"x10"
6"x10"
10"x14"10"x12"
6"x12"
10"x14"
12"x12" 12"x12"
12"x10"
12"x12" 12"x12"
12"x12"
10"x10"
6"x8"
12"x12"
14"x14"
12"x10"
18"x16"
Unoccupied
Unoccupied
CONTROL
1M111a
RAD/FLOURO
1M710
CONTROL
1M710a
TRAINING ROOM
1C114
MAIL ROOM
1C112a
CLOSET
1C106
CLOSET
1C104
PASSAGE
1C112
TESTING RM
1C110
CORRIDOR
1CC01
HAC
1C108
F/D
H-MH-1.1FD5
H-MH-1.1FD2
H -M
H -1
.1
FD
H -M
H -1
.1
FD
1 H -M
H -1
.1
FD
H -M
H -1
.1
FD
H-MH-1.1FE2
H-MH-1.1FD5
H-MH-1.1FD5
H-MH-1.1FD2
WAITING/LOUNGE
1G101
EGG ROOM
1F106
STRESS LAB
1F607
ECHO ROOM
ECG/ECHO
1F601
CARDIOLOGY
1M715
CARDIAC NUC
1F309
ELEVATOR
LOBBY
1F716
STORAGE
1G410
SECRETARY
1G402
CHIEF
1G403
POLICE
TRAINING
1h206
LOCKERS
FEMALE
1G303a
RETAIL
STORAGE
1G304
OFFICE
1N204
OFFICE
N203
OFFICE
1N404
OFFICE
1N403
OFFICE
1N201
OFFICE
1N202
OFFICE
1N405
ADMIN
1N401
OFFICE
1N205
OFFICE
1N206
CANTEEN
RETAIL
1N601
CONFERENCE
1M708
EMPLOYEE
1M307
OFFICE
1M402
SECRETARY
1M717
COMM
1M403 ELEC
1M307A
ELEC
1N601A
COMM
1N601B
12"x12"
10"x10"
10"x10"
14"x14"
8"x10"
8"x10"
8"x10"
12"x12"
14"x14"
12"x12"
29303136
D.2 D.1
1.2 8.1
C
D
E
F
G
D.7
F.4
E.4
C.7
32333435 A7
7.7
33.6
12"x14"
RR-A
100 CFM
RR-A
100 CFM
8"x8"
CD-A
135 CFM
8"x8"
10"x10"
12"x12"
12"x12"
12"x10"12"x10"
12"x12"
6"x8"
F/D
6"x6"
6"x6"
14"x14"
12"x12"
12"x12"
CD-A
260 CFM
CD-A
270 CFM
14"x12"
CD-A
60 CFM
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne f oo t
B
A
C
D
E
F th re e in ch es o ne f oo t
6"
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950Professional Seals:
EB / RLF of04 JUNE, 2010
BUILDING IS FULLY SPRINKLERED
01 AND 02
HOSPITAL/CLINIC LEVEL 1, AREA D,
H-MH1.1FD5-A
ZONE 5 DUCTWORK PLAN
BID ALTERNATE NO. 3
PG/JI 2250
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
AREA D, ZONE 5
C1
D3
D4
E2
A2 A3
B1 B2
D2
D5 D6
E1 E3
D1
FOR CONTINUATION UP, SEE H-MH-1.1ND5A.
GENERAL NOTES
No. Description Date
2 CPR 098 06/17/2011
3 CPR 068 07/08/2011
4 CPR 122 09/16/2011
5 CPR 160 10/14/2011
6 CPR 132 10/17/2011
7 CPR 236 03/09/2012
8 CPR 272 04/30/2012
9 CPR 353 10/25/2012
200 CFM
ER-A
950 CFM
ER-D
225 CFM
ER-D
225 CFM
ER-D
225 CFM
ER-D
225 CFM
CD-A
220 CFM
ER-C
310 CFM
CD-A
130 CFM
RR-A
190 CFM
CD-A
190 CFM
CD-A
145 CFM
ER-D
100 CFM
CD-A
200 CFM
CD-A
330 CFM
ER-D
100 CFM
CD-A
145 CFM
CD-A
145 CFM
SER-A
440 CFM
CD-A
100 CFM
ER-A
330 CFM
CD-A
230 CFM
RR-A
100 CFM
CD-A
100 CFM
RR-A
100 CFM
CD-A
220 CFM
ER-A
320 CFM
CD-A
145 CFM
CD-A
130 CFMCD-A
110 CFM
CD-A
100 CFM
CD-A
140 CFM
CD-A
60 CFM
CD-A
90 CFM
CD-A
110 CFM
CD-A
230 CFM
CD-A
90 CFM
CD-A
115 CFM
CD-A
120 CFM
RR-A
120 CFM
RR-A
110 CFM
CD-A
175 CFM
RR-A
175 CFM
CD-A
170 CFM
RR-A
170 CFM
CD-A
140 CFM
CD-A
175 CFM
RR-A
130 CFM
RR-A
120 CFM
RR-A
100 CFM
ER-D
100 CFM
SER-A
440 CFM
ER-D
100 CFM
CD-A
180 CFM CD-A
180 CFM
CD-A
180 CFM
ER-C
310 CFM
CD-A
460 CFM
CD-A
460 CFM
CD-A
460 CFM
CD-A
460 CFMCD-A
460 CFM
CD-A
130 CFM
RR-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
RR-A
100 CFM
RR-A
440 CFM
CD-A
470 CFM
RR-A
70 CFM
CD-A
70 CFM
CD-A
220 CFM
CD-A
100 CFM
CD-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
CD-A
50 CFM
RR-A
50 CFM
SRR-A
370 CFM
SSR-A
370 CFM
SRR-A
410 CFM
CD-A
100 CFM
RR-A
100 CFM
CD-A
100 CFM
RR-A
100 CFM
CD-A
50 CFM
ER-D
550 CFM
CD-A
50 CFM
CD-A
140 CFM
CD-A
300 CFM
CD-A
300 CFM
RR-A
540 CFM
CD-A
130 CFM
CD-A
180 CFM
CD-A
50 CFM
ER-D
100 CFM
CD-A
115 CFM
CD-A
115 CFM
RR-A
560 CFM
CD-A
280 CFM
CD-A
280 CFM
CD-A
80 CFM
RR-A
80 CFM
CD-A
150 CFM
RR-A
230 CFM
CD-A
120 CFM
CD-A
130 CFM
RR-A
350 CFM
CD-A
170 CFM
CD-A
200 CFM
CD-A
140 CFMCD-A
140 CFM
RR-A
280 CFM
CD-A
80 CFM
CD-A
200 CFM
CD-A
300 CFM
CD-A
300 CFM
CD-A
300 CFM
CD-A
300 CFM
RR-A
750 CFM
CD-A
460 CFM
CD-A
470 CFM
SSR-A
410 CFM
RR-A
130 CFM
RR-A
700 CFM
CD-A
375 CFM
CD-A
375 CFM
CD-A
375 CFM
CD-A
375 CFM
CD-A
180 CFM
SRR-A
325 CFM
SSR-A
325 CFM
RR-A
740 CFM
RR-A
740 CFM
CD-A
110 CFM
ER-D
100 CFM
CD-A
50 CFM
RR-A
140 CFM
RR-A
270 CFM
CD-A
210 CFM
RR-A
210 CFM
CD-A
140 CFM
RR-A
140 CFM
CD-A
90 CFM
RR-A
90 CFM
RR-A
100 CFM
CD-A
100 CFM
RR-A
280 CFM
RR-A
140 CFM
RR-A
90 CFM
CD-A
90 CFM
RR-A
90 CFM
CD-A
150 CFM
RR-A
210 CFM
RR-A
90 CFM
RR-A
110 CFM
CD-A
90 CFM
RR-A
90 CFM
RR-A
90 CFM
RR-A
80 CFM
CD-A
80 CFM
CD-A
115 CFM
CD-A
120 CFM
RR-A
135 CFM
CD-A
110 CFM
RR-A
115 CFM
RR-A
115 CFM
CD-A
115 CFM
CD-A
100 CFM
CD-A
100 CFM
CD-A
100 CFM
RR-A
1500 CFM
RR-A
1500 CFM
SSR-A
510 CFM
SSR-A
510 CFM SSR-A
510 CFM
H-FCU-1.17
12"x12"
16"x14"
10"x10"
10"x10"
10"x10"
12"x12"
10"x10"
12"x12"
16"x14"
16"x14"
10"x10"
10"x10"
12"x12"
10"x10"
10"x10"
12"x12"
10"x10"
14"x14" 16"x14"
10"x10"
14"x16"
14"x16"
14"x14"
14"x14"
14"x14"
12"x10"
12"x12"
12"x12"10"x10"
14"x14"
12"x14"
14"x14"
12"x12"
6"x6" 12"x12"
12"x12"
12"x12"
14"x16"
12"x12"
12"x10"
12"x12"
12"x12"
RR-A
100 CFM
RR-A
100 CFM
RR-A
100 CFM
14"x14"
12"x12"
8"x8"
12"x10"
12"x12"
10"x10"
10"x10"
RR-A
750 CFM
10"x10"
ER-A
950 CFM
ER-A
950 CFM
ER-A
950 CFM
12"x10"
12"x10"
12"x10"
14"x14"
14"x14"
14"x14"
14"x14"
14"x14"
CD-A
75 CFM
CD-A
60 CFM
14"x14" 16"x14" 16"x14"
10"x10"
14"x14"
8"x8"
12"x12"
12"x12"
14"x14"
12"x24"
10"x10"
10"x10"
10"x10"
12"x24"
14"x16"
16"x14"
12"x10"
12"x12"
8"x8"
12"x12"
10"x10" 10"x10"
SSR-A
100 CFM
SRR-A
100 CFM
8"x6"
8"x10"
12"x12"
12"x12"
10"x10"
14"x14"
14"x14" 8"x8"
12"x12"
12"x10"
14"x14"
10"x10"
14"x14"
10"x10"
10"x10"
12"x12"
12"x12"
14"x12"
12"x12"
10"x10" 10"x10"
10"x10"
10"x10"
16"x12"
10"x10"
14"x14"
12"x10"
8"x8"
12"x12"
Unoccupied
Unoccupied
MAIL ROOM
1C112a
ALCOVE
1CC09b
VRE OFFICE
1C909
VRE OFFICE
1C907
VRE OFFICE
1C905
VRE SUPERVISOR
1C901
VRE OFFICE
1C903
CORRIDOR
1CC09
VRE OFFICE
1C908
VRE OFFICE
1C603
STORAGE
1C605
CORRIDOR
1CC04
VRE OFFICE
1C904
INTERVIEW
1C201
INTERVIEW
1C203
VRE OFFICE
1C401
VRE OFFICE
1C604
CORRIDOR
1CC06
CUBICLES
1C602
VRE OFFICE
1C902
ALCOVE
1CC09c
JOB LAB
1C403 CUBICLES
1C606
CORRIDOR
1CC02
CLOSET
1C106
CLOSET
1C104
PASSAGE
1C112
TESTING RM
1C110
CORRIDOR
1CC01
HAC
1C108
WAITING
1C102
RECEPTION
1C101
HEARING RM
1C202
F/D F/D
F/D
F/D
F/D
F/D
F/D
H-MH-1.1FE2
H-MH-1.1FD5
H -M
H -1
.1 F
E
H -M
H -1
.1 F
E
H -M
H -1
.1 F
E
H -M
H -1
.1 F
E
10"x10"
12"x12"
12"ø
12"ø
12"ø
14"x14"
14"x14"
12"x12"
14"x14"
RR-A
130 CFM
RR-A
230 CFM
10"x10"
303136
6.1
3.2
C.2
A.2
D.2
B.2
C.1
A.1
B.1
1.2
8.1
2.0
7.3
A.05
32.2
2.8
1.4
32333435
6.7
7.7
B.3
34.4
35.4 31.7
A.02
32.8
A.03
32.5
33.8
12"x12" 16"x12"
CD-A
100 CFM
RR-A
100 CFM
RR-A
540 CFM
LD-A
215 CFM
LD-A
210 CFM
LD-A
215 CFM
10"x10"
8"x8"
20"x6"
8"x8"
16"x12"
8"x6"
LD-A
245 CFM
SERVING
H-TU-29.17
ANZ-C
1300 CFM
ANZ-C
1300 CFM
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950Professional Seals:
EB / RLF of04 JUNE, 2010
BUILDING IS FULLY SPRINKLERED
01 AND 02
HOSPITAL/CLINIC LEVEL 1, AREA E,
H-MH1.1FE2-A
ZONE 2 DUCTWORK PLAN
BID ALTERNATE NO. 2
PG/JI 2254
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA E, ZONE 2
D2
D5 D6
E1 E3
D1
FOR CONTINUATION UP, SEE
H-MH-1.1NE2-A.
GENERAL NOTES
No. Description Date
2 CPR 068 07/08/2011
3 CPR 105 10/06/2011
4 CPR 160 10/14/2011
5 CPR 132 10/17/2011
6 CPR 222 02/16/2012
7 CPR 361 12/07/2012
8 CPR 377 02/15/2013
9 CPR 399 06/28/2013
1 MOTORIZED BUBBLE TIGHT ISOLATION
DAMPER.
DRAWING NOTES2
88 8
PM
C
PM
C
15" SECONDARY
ROOF DRIANAGE.
24" ABOVE
FINISHED GRADE
(39170 S.F.)
15" RW UP &
DN (39170 S.F.)
8" RW UP &
DN (9705 S.F.)
15" SRW UP
(39170 S.F.)
P-528
P-528
P-528
P-401
P-528
P-401
P-401
P-701 P-401
P-401
P-528B P-505
P-528
P-528
P-528
P-560C
P-401
P-102
P-102
P-102
P-102
FLOOR
C.O.
FLOOR
C.O.
FLOOR
C.O.
FLOOR
C.O.
P-528
P-528
P-560C
P-803
P-803
6" CD UP & DN
FLOOR C.O.
FLOOR C.O.
2" W UP
& DN
1 1/2" V
UP & DN
1 1/2" V
UP & DN
H -P
L1 .1
FD
5-
A
H -P
L1 .1
FD
4-
A
H -P
L1 .1
FD
5-
A
H -P
L1 .1
FD
4-
A
C.T. (ED)
1E702
IMAGING RM-2
1K505c-2
MRI EQUIP
1E206a
HAC
1A609
WAIT
1M702
BIO MED OFFICE
1M204
NUC MED WAIT
1K510
VEST
1F201
CLEAN SUPPLY
1E604
NURSE
1F212
NURSE
1F214
IV PREP
1E304
STORAGE
1E402
ECG CUBICLE
1F404
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
STRETCHER
HOLD
1E301
RECEPTION
1E305
MRI WAIT
1E501
STAFF PHYSICIAN
1K802
STAFF PHYSICIAN
1K804
STAFF PHYSICIAN
1K806
C.T. (#2)
1E605
C.T.
1E601
NURSE
1F206
NURSE
1F204
NURSE
1F202
NURSE
1F208
NURSE
1F210
CORRIDOR
1MC02
COMPUTER
EQUIPMENT
1E201
CLEAN SUPPLY
1E205
SOILED UTILITY
1E203
PHYSICIAN
1F301
CORRIDOR
1EC07
CONTROL RM
1E603
NURSE
PRACTIONER
1K705
TLT
1E404
DRESS
1E403
DRESS
1E401
CORRIDOR
1EC03
CLEAN SUPPLY
1K203
PATIENT DOSE
1K205
READING/CONSULT
1K502
RECEPTION
1K508
RSO/PHYSICIST
OFFICE
1K504
EXAM RM
1K509
TLT
1K511
PASSAGE
1KC08
CHIEF NUC MED
OFFICE
1K807
PROFESS
NON-PHYSICIAN
1K805
STAFF PHYSICIAN
1K803
CORRIDOR
1EC05
CHEST RM
1M206
COMMON
VIEWING RM
1K801
STAFF TLT
1F402
ENTRY
1K505
THYROID UPTAKE
1K503
TECH WORK
AREA
1K505d
CORRIDOR
1KC05
TLT
1K513
CORRIDOR
1KC06
ELEC
1E610
CORRIDOR
1EC06
CORRIDOR
1KC07
EQUIP
1KC06a
CORRIDOR
1FC02
IMAGING RM
1K505a
IMAGING RM
1K505b
CORRIDOR
1EC04
CRASH CART
1E306
WHEELCHAIR &
STRETCHER
WAITING
1E608
MRI ROOM
1E202
MRI CONTROL
1E302
MRI CONTROL
1E204
CORRIDOR
1EC02
MRI ROOM
1E206
NUC WASTE STOR
1K202
IV PREP
1K214a
PET SIM UPTAKE
1K212
PET UPTAKE
1K210
UPTAKE
1K208
UPTAKE
1K206
CORRIDOR
1KC02
CORRIDOR
1EC01
10" SECONDARY ROOF DRIANAGE. 24"
ABOVE FINISHED GRADE (18616 SF)
3" RW UP & DN (1297 S.F.)
3" V UP & DN
P-806
MOUNT 1'-6" O.C. ABOVE
ASSOCIATED LEVEL.
1" CW DN
1" CW DN
FLOOR C.O.
FLOOR C.O.
FOR EXACT LOCATION
OF 3/4" CW UP TO
YARD HYDRANT FOR
MOBILE MRI VECHICLE
SEE CIVIL DRAWING
WALL C.O.
FD-V
H-PL1.1FE1
H-PL1.1FD4-A
H-PL1.1FE1
H-PL1.1FD4-A
H-PL1.1FD4-A
H-PL1.1FD1
H-PL1.1FD4-A
H-PL1.1FD1
H -P
L1 .1
FE
2-
A
H -P
L1 .1
FE
3738394041
C
D
E
F
G
D.9
D.7
F.4
E.4
C.7
E.6
D.6
40.6 39.440.5
37.2
39.7
H-CRAC-12
H-CRAC-13
H-CRAC-14
FOR EXACT LOCATION
OF 3/4" CW UP TO
YARD HYDRANT FOR
MOBILE MRI VECHICLE
SEE CIVIL DRAWING
FD-C
FD-C
FLOOR
C.O.
ROUTE CONDENSATE
TO FLOOR DRAIN
MAINTAIN 2" AIR GAP
ROUTE
CONDENSATE TO
FLOOR DRAIN
MAINTAIN 2" AIR GAP
FLOOR
CO
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA D, ZONE 4
D2
D5 D6
E1 E3
D1
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne f oo t
B
A
C
D
E
F th re e in ch es o ne f oo t
6"
6" on e an d on e ha lf in ch es o ne f oo t on e in ch o ne f oo t
6" 6" th re e qu ar te rs in ch o ne f oo t on e ha lf in ch o ne f oo t th re e ei gh th s in ch o ne f oo t on e qu ar te r in ch o ne f oo t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
01 AND 02
4322Dwg. ofGO/PPG
ZONE 4 PLUMBING PLAN
BID ALTERNATE NO. 3
HOSPITAL/CLINIC LEVEL 1, AREA D,
H-PL1.1FD4-A
1. 1" PUMPED CONDENSATE TO PLUMBING DRAIN
LOCATED IN INTERSTITIAL SPACE BY
MECHANICAL.
2. 3/4" COLD WATER SUPPLY TO FLOOR MOUNTED
AIR CONDITIONING UNIT FOR HUMIDIFIERS.
No. Description Date
1 CPR 122 09/16/11
2 CPR 234 02/16/12
3 CPR 236 03/09/12
4 CPR 382 03/15/13
FLOOR
C.O.
FLOOR C.O.
FLOOR C.O.
3" AW UP &
DN (28 FU)
3" AV UP & DN
4" VENT UP & DN
6" SAN UP & DN
6" SAN UP &
DN (141 FU)
4" VENT
UP & DN
P-528
P-528AP-528A
P-528
P-528
P-401
P-502
P-528A
P-528A
P-528A
P-528A
P-528A
P-401
P-401 P-401
P-528
P-528
P-401
P-401
P-202P-404
P-201
P-701
P-702
P-404
P-702
P-404
P-502
P-528
P-102
P-101 P-101
P-102
P-102 P-102
P-102
P-101
P-102
P-102
P-102
FLOOR C.O.
FLOOR
C.O.
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
3" SIDE OUTLET
AD TYPE A
P-102 P-528A
P-701
P-609
P-404
P-404
P-404
FLOOR
C.O.
2" W UP & DN
1 1/2" V UP
2" W UP & DN
FD-D
(TYP OF 3)
P-702
FLOOR C.O.
H-PL1.1FD5-A
H-PL1.1FD2-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
-A
H-PL1.1FD5-A
H-PL1.1FD2-A
CLOSET
1C106
CLOSET
1C104
RAD/FLOURO
1M710
CONTROL
1M710a
1 1/2" V UP & DN
STAIR
1ES01
ELEVATOR
1EE02
ELEVATOR
1EE01
ELEVATOR
1FE02
ELEVATOR
1FE01
WAIT
1M702
BIO MED OFFICE
1M204
WAITING
1G404
OFFICE (PVA)
1N404
OFFICE
(FDVA/STATE)
1N203
RECEP(FDVA/STATE)
1N201
OFFICE
1H202
OFFICE
1H204
PASSAGE
1HC02
CHIEF
NON-INVASIVE
1F203
VEST
1F201
OFFICE
(FDVA/STATE)
1N204
OFFICE (DAV)
1N403
OFFICE
1N405
PHYSICIAN
1F303
CHIEF OF
CARDIOLOGY
1M715
ECG CUBICLE
1F404
STRESS
LAB/ECHO
1F602
STRESS
LAB/ECHO
1F604
STORAGE
1F101
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
TLT
1F403
ELEC
1N601a
CORRIDOR
1FC04
CHIEF
1G403
PACEMAKER/HOLTER
MONITOR ROOM
1F307
CORRIDOR
1FC05
HAC
1F401
CORRIDOR
1FC03
Space
2C558
ECG/ECHO
READING
1F601
ECHO ROOM
1F605
CORRIDOR
1FC06
STRESS LAB
1F607
STRETCHER
ALCOVE
1FC04a
ECG CUBICLE
1F104
CORRIDOR
1FC01
OFFICE
(FDVA/STATE)
1N206
PASSAGE
1NC02
OFFICE
(FAVA/STATE)
1N205
CORRIDOR
1NC04
OFFICE (PVA)
1N406
LOCKERS MALE
1G302a
COMM
1N601b
CANTEEN RETAIL
1N601
POLICE TRAINING
ROOM
1H206
HAC
1G305
EVIDENCE STOR
1H206a
TLT & SHWR
FEMALE
1G303b
VESTIBULE
1G303
TRAINING ROOM
1G408
LOCKERS
FEMALE
1G303a
STORAGE
1G410
OFFICE(COUNTY)
1G101b
OFFICE(COUNTY)
1G101a
CO-ORDINATOR
1G406
OFFICE/ADMIN(DAV)
1N401
TLT & SHWR
MALE
1G302b
VESTIBULE
1G302
ENTRY
1GC04
SECRETARY
1G402
SERVICE OFFICER
1G401
PHYSICIAN
1F301 CARDIAC NUC
IMAGING
1F309
DRESS
1M704
PACS OFFICE
1M406
ADPAC OFFICE
1M404
DRESS
1M714
RAD/FLOURO
1M148
CHEST RM
1M206
CONTROL
1M206a
TLT
1M304
TLT
1M302
CORRIDOR
1MC03
WORK
1F808a
STAFF TLT
1F402
ECG ROOM
1F106
RADIOLOGY
LOCKERS AND
TOILETS
1M303
PASSAGE
1MC04
CONFERENCE
1M718
COMM
1M403
EMPLOYEE
BIO-SAFETY
1M307
ELEC
1M307a
ELEVATOR
LOBBY
1F716
CORRIDOR
1FC07
Space
2C933
TECH WORK
1M210
SOILED HOLD
1M306
RF TLT
1M706
RF TLT
1M712
PATIENT REP
1F804
ELEC
1F802
SECRETARY
1M717
OFFICE (VFW)
1N202
OFFICE/RECEP(PVA)
1N402
CORRIDOR
1GC01
PATIENT REP
1F806
PATIENT
STORAGE
1F716a
ELEV LOBBY
1GC02
WAITING/LOUNGE
1G101
COFFEE SHOP
1F808
CORRIDOR
1HC09
CORRIDOR
1MC08
ELEVATOR
1FE03
CHIEF TECH
OFFICE
1M402
PUBLIC TLT
1F808b
3/4" FW
1/2" CW
1/2" HW
3/4" 3/4"
3/4" 1/2" HW
1/2" FW
1/2"
1/2"
1"
HW & CW UP
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
CW UP
CW & HW UP
FLOOR C.O.
WALL C.O.
FLOOR C.O.
FLOOR C.O.
FLOOR C.O.
P-528A
H-PL4.001
H-PL4.001
H-PL1.1FE2-A
H-PL1.1FD5-A
H-PL1.1FE2-A
H-PL1.1FD5-A
H -P
L
.1 F
D
H -P
L
.1 F
D
-A
H -P
L
.1 F
D
H -P
L
.1 F
D
-A
H -P
L
.1 F
E
-A
H -P
L
.1 F
E
P-811
1.2
C
D
E
F
G
D.9
35.2
D.7
F.4
E.4
C.7
32333435 A7
C.81
C.91
32.532.7
33.6
P-811
P-811
P-811 P-811
P-811
FD-C
FD-C
P-528
1 1/2"
2"FD-C WITH
FUNNEL
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
AREA D, ZONE 5
C1
D3
D4
E2
A2 A3
B1 B2
D2
D5 D6
E1 E3
D1
1. 1/2" SAN UP.
2. 1/2" HW FROM SINK TO DISHWASHER. 1 1/2" DRAIN
FROM DISHWASHER TO SINK TAILPIECE.
3. NOTE NOT USED.
4. REFER TO KITCHEN CONSULTANT HQ-F SERIES
DRAWINGS FOR DRAIN LOCATIONS.
5. 1/2" CW FROM TRAP PRIMER TO FD-C.
6. 1 1/2" VENT FROM BELOW CONNECTION TO VENT
FROM URINAL P-201.
7. 1 1/2" VENT FROM BELOW CONNECTION TO VENT
FROM WATER CLOSET P-101.
8. EXTEND 1 1/2" SANITARY DRAIN FROM RELOCATED
P-528 SINK AND CONNECT TO EXISTING 2" VERTICAL
SANITARY DRAIN THAT CONTINUES DOWN THRU FLOOR.
9. PROVIDE CW, HW, VENT AND DRAIN STUB OUT FOR
FUTURE P-528A IN-COUNTER SINK INSTALLATION.
10. 1-1/2" VENT UP IN WALL TO INTERSTITIAL SPACE.
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
01 AND 02
4322Dwg. ofGO/PPG
ZONE 5 PLUMBING PLAN
BID ALTERNATE NO. 3
HOSPITAL/CLINIC LEVEL 1, AREA D,
H-PL1.1FD5-A
No. Description Date
1 CPR 078 05-12-11
2 CPR 128 08/04/11
3 CPR 160 10/14/11
4 CPR 236 03/09/12
5 CPR 272 04/30/12
15" SECONDARY
ROOF DRIANAGE.
24" ABOVE
FINISHED GRADE
(44751 SF)
15" SECONDARY
ROOF DRIANAGE.
24" ABOVE
FINISHED GRADE
(38320 SF)
P-101
4" VENT UP
6" SAN UP &
DN (182 FU)
8" SAN UP &
DN (624 FU)
4" VENT
UP & DN
4" VENT UP & DN
8" SAN UP &
DN (632 FU)
15" SRW UP (38320 SF)
15" RW UP &
DN (44751 SF)
P-560B
P-117
TYP
P-401
P-560B
P-401
P-401
P-401
P-528E
P-528E
P-120
P-404
P-201
P-404
P-404
P-404
P-502
P-609
FLOOR C.O.
P-101
P-102
P-102 P-102
P-101
P-102
P-102
FLOOR C.O.
P-201
P-102
P-202P-609
P-502
2" W UP & DN
2" W UP
& DN
H -P
L
.1 F
E
-A
H -P
L
.1 F
E
-A
H -P
L
.1 F
E
-A
H -P
L
.1 F
E
-A
VRE OFFICE
1C903
VRE SUPERVISOR
1C901
VRE OFFICE
1C902 VRE OFFICE
1C904
JOB LAB
1C403
VRE OFFICE
1C401
CORRIDOR
1CC01
TESTING RM
1C110
HAC
1C108
CLOSET
1C106
CLOSET
1C104
RECEPTION
1C101
CORRIDOR
1CC04
INTERVIEW
1C203
CORRIDOR
1CC02
INTERVIEW
1C201
HEARING RM
1C202
WAITING
1C102
1 1/2" V UP & DN
LOBBY
1B403
WAITING
1B403d
EQ. ALCOVE
1AC07b
VESTIBULE
1B301
OFFICE
1A803
OFFICE
1A801
EXAM/TREAT
1A715
GYN EXAM/
TREAT
1A122
PATIENT TLT
1A115
PATIENT TLT
1A714
EXAM/TREAT
1A109d
PHYSICIAN
1F505
PHYSICIAN
1F507
ANTE RM
1A719
ISOLATION
1A721
ISOLATION
1A717
ADMISSIONS
CHECK IN
1B204
ADMISSIONS
CHECK IN
1B202
PROCEDURE
CHECK IN
1B203
ED TLT MALE
1A502
ED TLT FEMALE
1A504
HAC
1B604
PUBLIC TLT
FEMALE
1B601
CORRIDOR
1BC02
PHONE
1A501
CORRIDOR
1AC05
PROCEDURE
CHECK IN
1B205
CORRIDOR
1AC08
TRIAGE
1A119
TRIAGE
1A718
PHYSICIAN
1F503
GYN EXAM/
TREAT
1A120
CONSULT
1A124
CORRIDOR-1
1BC04-1
CORRIDOR
1FC05
Space
2C558
SECURITY
SCREENING
1B403c
FIRE COMMAND
1B505
OPERATIONS
1B303a
CORRIDOR
1BC03
VESTIBULE
1B303
HOLDING
1B303b
CORRIDOR
1FC07
MAS WORKRM
1B201
COMM
1B201b
KIOSK CHECK-IN
1BC04aELEC
1B201a
VENDING
1A121a
ARMORY
WORKRM
1B303c
WAITING
1A121
ESCORT
SERVICES
1B701
CORRIDOR
1BC07
CORRIDOR
1BC06
ELEVATOR
LOBBY
1B405
OFFICE OF
DECEDENT
AFFAIRS
1B703
WAITING
1B403b
15" RW UP &
DN. (38320 SF)
FLOOR C.O.
P-806
MOUNT 1'-6" O.C. ABOVE
ASSOCIATED LEVEL.
P-806
MOUNT 1'-6" O.C. ABOVE
ASSOCIATED LEVEL.
3/4" CW UP
3/4" CW
UP
FLOOR C.O.
CW UP HW & CW UP
PUBLIC TLT MALE
1B600
H-PL1.1FE2-A
H-PL1.1FD5-A
H-PL1.1FE2-A
H-PL1.1FD5-A
H -P
L
.1 F
E
-A
H -P
L
.1 F
E
H -P
L
.1 F
E
-A
H -P
L
.1 F
E
'-6
'-6
7.1
2.2
C.2
A.2
D.2
B.2
C.1
A.1
D.1
B.1
1.2
8.1
A
C
B
2.0
7.3
A.05
34.5
34.2 32.4
32.2
A.04 2.8
1.4
32333435 A7
7.7
34.4
A.01
35.4 31.7
D.3
32.8
A.03
32.5
33.8
A.07
FD-C FD-C
FD-C
FD-C
6" RW UP
TO RD-16" SRW UP
TO RD-2
(2,112 SQ. FT.)
P-560B
8" SECONDARY
ROOF
DRIANAGE. 24"
ABOVE FINISHED
GRADE
(10203 SF)
8" RW UP & DN
8" SRW UP
(10203 SF)
WALL
C.O.
6" RW & SRW UP
(3,917 SQ. FT.))
R W
LOBBY
1B403
WAITING
1B403d
WAITING
1B403b
34.5 34.2 32.4 32.2
A.04
A734.4
A.02
32.8
A.03
33.8
S R
W 6" SECONDARY
ROOF
DRIANAGE. 24"
ABOVE FINISHED
GRADE
(4,112 SQ. FT.)
6" RW DN
(4,112 SQ. FT.)
6" RW UP
TO RD-1
(2,164 SQ. FT.)
6" SRW UP
TO RD-2
(2,112 SQ. FT.)
6" RW UP
TO RD-1
6" SRW UP
TO RD-2
6"
6"
6" 6"
6"
6"
WALL
C.O.
6" SRW UP
TO RD-2
(1,958 SQ. FT.)
6" RW UP
UP TO RD-1
(1,958 SQ. FT.)
6"
CO
6"
8"
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA E, ZONE 2
D2
D5 D6
E1 E3
D1
1/8" = 1'-0"
Level 1 Area E2 - Plumbing - Alternate #2
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
o n e e ig h th i n c h o n e f o o t
B
A
C
D
E
F th re e i n c h e s o n e f o o t o n e a n d o n e h a lf i n c h e s o n e f o o t o n e i n c h o n e f o o t th re e q u a rt e rs i n c h o n e f o o t o n e h a lf i n c h o n e f o o t th re e e ig h th s i n c h o n e f o o t o n e q u a rt e r in c h o n e f o o t
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
BUILDING IS FULLY SPRINKLERED
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950
04 JUNE, 2010
Professional Seals:
EB / RLF
NOTES:
SHEET NOTES:
01 AND 02
4322Dwg. ofGO/PPG
ZONE 2 PLUMBING PLAN
BID ALTERNATE NO. 2
HOSPITAL/CLINIC LEVEL 1, AREA E,
H-PL1.1FE2-A
1/8" = 1'-0"
Partial Plan - Level 1 - Plumbing
1 1/2" CW FROM TRAP PRIMER DN TO FD-C.
2. 2" VENT FROM BELOW.
3. CONNECT 2" VENT TO 4" VENT IN PIPE CHASE.
No. Description Date
1 CPR 078 05-12-11
2 CPR 130 08/25/11
3 CPR 160 10/14/11
4 CPR 222 02/27/12
5 CPR 323 08/16/12
UP
DN
DD
D
D
GENERAL
PURPOSE/X-RAY
ROOM/(RAD
ROOM)
1M103
DIGITAL
ARCHIVE
1M604
TLT
1M302
SOILED HOLD
1M306 CLEAN UTILITY
1M308
CONCESSIONS
1M811
EMPLOYEE
BIO-SAFETY
1M307
RADIOLOGY
LOCKERS AND
TOILETS
1M303
COMM
1M403
OFFICE
(FDVA/STATE)
1N206
OFFICE
(FDVA/STATE)
1N204
OFFICE (VFW)
1N202
OFFICE
(FAVA/STATE)
1N205
OFFICE
(FDVA/STATE)
1N203
RECEP(FDVA/STATE)
1N201
OFFICE (PVA)
1N406
OFFICE (PVA)
1N404
OFFICE/RECEP(PVA)
1N402
OFFICE/ADMIN(DAV)
1N401
OFFICE (DAV)
1N403
OFFICE
1N405
LOCKERS
MALE
1G302a
TLT & SHWR
MALE
1G302b
RETAIL
STORAGE
1G304
TLT & SHWR
FEMALE
1G303b
HAC
1G305
EVIDENCE
STOR
1H206a
OFFICE(COUNTY)
1G101b
OFFICE(COUNTY)
1G101a
POLICE
TRAINING
ROOM
1H206
TRAINING
ROOM
1G408
CO-ORDINATOR
1G406
WAITING
1G404
STORAGE
1G410
OFFICE
1H204
SERVICE
OFFICER
1G401
CHIEF
1G403
OFFICE
1H202
OFFICE
1H203
CLERICAL
1H201
ECG CUBICLE
1F104
STRESS
LAB/ECHO
1F604
STRESS
LAB/ECHO
1F602
STAFF TLT
1F402
TLT
1F403
HAC
1F401
STORAGE
1F101
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
PHYSICIAN
1F303
PHYSICIAN
1F301
PACEMAKER/HOLTER
MONITOR
ROOM
1F307
CHIEF
NON-INVASIVE
1F203
UNASSIGNED
1F309
ECG/ECHO
READING
1F601
ECHO ROOM
1F605
ECG ROOM
1F106
STRESS LAB
1F607
PATIENT
STORAGE
1F716a
RAD/FLOURO
1M708
PACS OFFICE
1M406
ADPAC OFFICE
1M404
BIO MED
OFFICE
1M204
CONFERENCE
1M718
RF TLT
1M712
RF TLT
1M706
CHIEF OF
CARDIOLOGY
1M715
SECRETARY
1M717
GENERAL
PURPOSE/X-RAY
ROOM/(RAD
ROOM)
1M105
TECH WORK
1M210
ELEC
1N601a
CORRIDOR
1MC07
WAIT
1M702
CHEST RM
1M206
CHIEF TECH
OFFICE
1M402
CANTEEN
RETAIL
1N601CORRIDOR
1MC03
PASSAGE
1MC04
CORRIDOR
1MC06
CONTROL
1M103a
COMM
1N601b
CORRIDOR
1NC04
PASSAGE
1NC02
CORRIDOR
1GC03
WAITING/LOUNGE
1G101
STAIR
1ES01
ELEV LOBBY
1GC02
COFFEE SHOP
1F808
WORK
1F808a
CORRIDOR
1FC06
PATIENT REP
1F806
ELEC
1F802
ELEVATOR
LOBBY
1F716
PASSAGE
1HC02
VESTIBULE
1G303
CORRIDOR
1FC04
DETECTIVE
OFFICE
1H410
DRESS
1M714
CORRIDOR
1MC08
SECRETARY
1G402VEST
1F201
PATIENT REP
1F804
PUBLIC TLT
1F808b
CORRIDOR
1MC02
TECH WORK
1M210
CORRIDOR
1FC03
CORRIDOR
1FC05
ELEVATOR
1EE02
ELEVATOR
1EE01
ELEVATOR
1FE03
ELEVATOR
1FE01
CORRIDOR
1FC07
LOCKERS
FEMALE
1G303a
VESTIBULE
1G302
CORRIDOR
1FC08
PHYSICIAN
1F505
PHYSICIAN
1F503
CONTROL
1M206a
HAC
1G304a
OFFICE
1H206b
OFFICE
1H206c
CORRIDOR
1FC02
303136
1.2 8.1
C
D
E
F
G
D.9
30.235.2
D.7
F.4
E.4
C.7
1.4
32333435 A7
7.7
32.532.7
33.6
K.8
K.9 a
D D
D
D
D
D
D
D
D
D
D
D
D
D D D D
D
D
D
D
D
HA2
HA11
HF10
HA1
HA3
HA1
HA3
HA11
HA3
HA3
HA3
HA2
HA2 HA3
HA1
HA2
HF1
HA1
HA3
HA3
HF1
HA3
HA3
HA1
HA3
HA3
HA2
HA3
HA3
HA3
HA3
HA3
HA1
HA3
HA2
HA1
HA3
HA3
HA3
HA3 HA3
HA3
HA11 HA11 HA11
HA11
HA2
HA2
HA2
HA3
HA3 HA3
HA3
HF10
HF10
HA3
HA3
HA3
HA3
HA3
HA3
HA11
HA11
HA1 HA1 HA3
HA3
HA11
HA3 HA3
HA11
HA11HA11 HA11HA11
HA11
HA11 HA11
HA3
HA1HA1
HA1
HB2 HB2 HB2
HB2HB2HB2HB2
HA1 HA1 HA1
HA3 HA3
HA3
HA3 HA3
HA11
HA11
HA3
HA3 HA3
HA11
HA3
HA3
HA3 HA3
HA11
HA3
HA3
HA3
HA11
HA3
HA3
HA3
HA3
HA1 HA1 HA1
HA2
HA2 HA2
HA2
HA2HA1
HB1
HB1
HB1
HA2
HA2
HA2
HA1HA1 HA1
HA2
HA3
HA3
HA3
HA3
HA3
HA3
HA3
HA3
HB2 HB2
HB2 HB2
HB2
HA2
HB2
HA9
HA9
HA1
HA1
HA1
HA1
HA3
HA3
HA3
HA3
HA3
HA3 HA3
HA3
HA3HA3 HA3
HA3
HA3
HA3
HA1 HA1 HA1 HA1 HA1 HA1
HB2
HB2 HB2 HB2
HB2 HB2
HB2
HB2 HB2
HB2 HB2
HB2
HA1 HA1
HA2
HA9 HA9 HA9
HA9
HA9 HA9
HA1
HA1
HA1HA1
HA9
HA9HA9
HA9
HA9
HA3
HA3
HA2
HA2
HA2
HA3HA3HA3
HA9HA9
HA9
HA9
HA9
HA3
HA3HA3HA3 HA3
HA3
HA1HA1HA1
HA9
HB2
HB2
HB2
HA3
HA9 HA9
HB2
HB2
HB2
HB2
HB2
HB2 HB2
HB2
HA9
HA9
HA9
HA9
HA9
HA3
HA3
HA3
HA3
HA3
HA1
HA1
HA3
HA11
HA1
HA3
HA1
HA11
HA3
HA3
HA3
HB1 HB1
HA1 HA1
HA3
HF10 HF10
HA3
HHC
HHC
HW2
HW2
HA2HA2
HA3
HA3
HA1
HA1
HB1
HB1
HW
HB1
HW
HA1
HA1
HA1
HA1
HB1
HW
HA14
HB1 HB1
HU
HU
HU
a a,b a,b a,b a,b a,b a,b a a a a,b a,b a a,b a,b a,ba,b a,b a
HU
HU
a
HF1
HWHW
HB1 HB1 HB1
HA11
HA1 HA1 HA1 HA1
HA1
HA3
HU
HU
HU
HU
HU
HA3
HU
HU HU
a a,b a,b a,b
HU
HU HU
g
HB1
HW
HU
b b b b b bbb a a a a a,b a,b a,b a,b a a a,b a,b a a a,b a,ba,ba,b
HU
a a,b a,b
HU
HU
a a a,b a,ba,ba,ba,b a,b
HB2HB2
HB2
HB2
a,b a,b a a a,b a,b a,b a,ba,b
D a a a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,ba,b a,b a,b a a a a a a a a a a a a a a a,ba,b a,b a,b aa,b a,b a a,b a,b a,b a,b a a a a,ba,b a,b a,b a,b a,b a a a,b a,b a,b a,b a a,b a,b a,b a,b a a,ba,b a,b a,b a,b a,ba,b
HA3
HA3
b c c cc c a,b a,b c c
D
HB1
HB1
HB1
HW
HW
HF1
HF1
HF2
HF3
a
HB1
HW
DD
H1D5HN1- 2
H1D5HN1- 3
HB1
H1D6HN2- 4
a,b a,b a,b a a,ba,b a,b a,b a,b b b b b ee ff ff f ff a a aa a a a a c c c c
D Df aDc3e 3b
D b
HB2 b bb
HB1
b b b
HB1
b b b b bb b
HB1
b
HB1
b b b b b b b b b b a b b b b b b b bb b b b b b
HB1
b b b
HW
b
H1D5HN3
b a,b
HE
HB2
D
H1D5HN2- 3
HA1
HA1
H1D5HN2- 1
H1D5HN1- 4
H1D5HN1- 1
H1D5HN1- 6
H1D5HN2- 4 H1D5HN2- 9
HF9
HF9HF8
b
HA3
HUHW
HA9HA9HA9HA9
HA9
HA9HA9HA9HA9
HA9 HA9 HA9
HA9HA9 HA9 HA9
HA9 HA9
HA9 HA9
HA9 HA9
HA9
HA9
HA9 HA9
HA9
HA9HA9
HA9
HA9 HA9 HA9
HA9HA9
HA9 HA9
HA9HA9
HA9
HA9
HA9
HA9
HA9
HA9HA9
HA9
HA9
HA9
HA9HA9
HA9HA9
HA9
HA9
HA9
HA9 HA9
HA9 HA9
HA9HA9
HA9
HA9
HA9
HA9
HA9
HA9 HA9 HA9
HA9
HA9HA9
HA9HA9HA9
HA9
HA9
HA9
HA9 HA9 HA9 HA9
HA9
HA9
HA9
HA9
HA9HA9HA9HA9
D
D D
D
D
D
D
HU
HA9
HA9
H1D5HN3- 1
HA3
a,b
D
HE
D
D D
D
D
D
D
D
D
D
D D
D
D
D D
D D
D
D
HT1
HT2HT2
H1D5HC1- 3
D D
D
D
D D
D
D
D
D
D
D
D
HA2
H1D5HN2- 6
D
HB2
HB2
HA9
a
UP TO 3RD FLOOR CKT.
TYPICAL.
HA9
HT1 HT1 HT1
ZONE KZONE I
ZONE G,H
ZONE J
ZONE E,F
DOWN
UP
UP
UP
DOWN
DOWN
HW2
HP
HP
D b D a a a a a b b b b b b b b b b a a a a a
U
HT3
HT3
2 3
D
D
D a
D
D
D
H1D5HC1- 1
HB1 HB1
HB1
H1D5HC1- 2
D
H1D5HN2- 7
U
HU
HU
D D
HE
HA9HA9HA9
HA9 HA9
HA9
HA9
HA9 HA9
HE
HE
HA2
HA1
HA2
HF10
HF10
HF10 HF10
HA11
HA1
HE
HA1HA1
HA1
HA1
HE
HE
HA1
HA1HA1
HA1 HA1 HA1 HA1
HA1
HA1
HA1
HA1
HA1
HA1
HA1
HA11
HA11HA11
HA11
HA3
HA3
HE
HA3
HE
HA11
HE
HE
HE
H1E2HS1-2
HB16 HB16
HE
H1E2HS2-2
HB1
HB1
HA11
HA11
HE
HE
HE
HB1
HE
HB1
HA11
HA11
HE
HE
HE
HA1
H1E2HS2-7
HE
H1E2HS2-9
HE
HE
HE
HB5
HB5
HB1 HB1
HB1 HB1
HB1HB1
HB1 HB1
HB1 HB1
HE
HB19 HB19HB19
HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19
HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19
HB1
HB1
H1E2HN1-10
HB6
HT2 HT2HT2HT2
HT1
HT2
HT2
HU HU
HU
HU g g
HP
HP
HUHU
HB2
HB2
HU
HU
HU
HF1 HF1
HB1
HU
HU
HU
HB2
HU
a,b b b b b b b
3 3 a a a bb b
D a bbb b
D
HU HUc c c c c c a a a a a a a a a a a a a 1 b b
HU
d d d d d d e e e a,b ccc b b bb a a a a a a aa a a a a aa b b a,b c c c b a a c c c cc a,b a,b a a a a e e e e e d d d d d b b b b b b b b a a a a a,b D f d d f f f f gHU HU HU a b c c a,b b b b b a a
HA9
HA9
HA9
d
HA2
HA2
U a a a
U
U
U
U
U
U b
U
U
U
U
U
U
U
UU
HB6
HU
d
H B
HB2
HB2
HB2
H B
HB2
HB2
HB2
HB2
HA9
HA9
HA9
HA9
HB2
HB2
b b b b a a a c a a a a aaa a3b cDD
D
D c c c c c
HE
RAD/FLOURO
1M710
CONTROL
1M710a
MAIL ROOM
1C112a
HA3
a,b
HA3
a,b
HA3
a,b
D
D a b a b
HA3
a,b
HB1 HB1
HA1
a
HF10
16D
16D
HB2
HB2
a
3e
3b 3b d
HU
d
HB2 a
HB2
a
D
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot
6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950Professional Seals:
EB / RLF of04 JUNE, 2010
BUILDING IS FULLY SPRINKLERED
01 AND 02
HOSPITAL/CLINIC
H-EL1.1FD5-A
LEVEL 1, AREA D, ZONE 5
LIGHTING PLAN BID ALTERNATE NO. 1
EB/RLF 3662
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
AREA D, ZONE 5
C1
D3
D4
E2
A2 A3
B1 B2
D2
D5 D6
E1 E3
D1
D7
CLINIC
HOSPITAL
P-W P-E
A4
E4
W
KEY NOTES:
H -E
L1 .1
FD
5-
A
H -E
L1 .1
FD
H-EL1.1FE2-A
H-EL1.1FD5-A
No. Description Date
4 CPR 122 09/16/2011
5 CPR 178 11/07/2011
6 CPR 219 01/16/2012
7 CPR 236 03/09/2012
8 CPR 272 04/30/2012
9 CPR 319 08/02/2012
10 CPR 323 08/16/2012
11 CPR 373 01/24/2013
GENERAL NOTES:
1. ELECTRICAL CONTRACTOR SHALL COORDINATE CEILING TYPE WITH FIXTURE FLANGE OR GRID TYPE
MOUNTING PRIOR TO INSTALLATION.
2. ALL UNDER COUNTER LIGHTING FIXTURES SHALL BE CIRCUITED TO NEAREST RECEPTACLE. A WALL SWITCH SHALL BE INSTALLED TO CONTROL UNDER CABINET LIGHTING FIXTURES. WHERE TWO OR MORE UNDER CABINET LIGHTING FIXTURES, TYPE "HU", SHALL BE CIRCUITED TO THE SAME CIRCUIT AND CONTROLLED BY THE SAME WALL SWITCH. MOUNTING LOCATION OF FIXTURES SHALL BE AT CENTER OF
CABINETS.
3. LIFE SAFETY LIGHTING SHALL BE CONTROLLED BY CIRCUIT BREAKER IN LIFE SAFETY PANEL EXCEPT
WHERE INDICATED ON THE DRAWING.
4. OCCUPANCY SENSOR IN OFFICE SHALL BE THE DUAL TECHNOLOGY TYPE WITH THE 20'x20' PATTERN (OR DESCRIPTION 3), UNLESS OFFICE IS LARGER THAN 20'x20'.
5. ALL HOME RUNS SHALL BE ROUTED FROM THE DEVICE/FIXTURE INDICATED TO THE APPROPRIATE WIREWAY WITHIN THE INTERSTITIAL SPACE ABOVE. SEE 1/H-EP5.510 FOR INTERSTITIAL FLOOR
PENETRATION DETAIL.
6. CORRIDOR OCCUPANCY SENSORS SHALL BE THE ' ULTRASONIC ' TYPE WHEN SPACE MORE THAN 40' APART. ALL CORRIDOR FIXTURES OF NORMAL CIRCUITRY SHALL BE CONTROLLED BY OCCUPANCY
SENSOR LOCATED IN SAME CORRIDOR, UNLESS OTHERWISE INDICATED BY SWITCH LEGS.
7. CIRCUIT ALL IN-USE LIGHT "HN2" TO 120V CIRCUIT SERVING THE RESPECTIVE IMAGING SUITE AND CIRCUIT PER IMAGING EQUIPMENT MANUFACTURERS RECOMMENDATIONS. (CIRCUIT FROM RADIOLOGY EQUIPMENT)
1 1
H -E
L1 .1
FD
H -E
L1 .1
FD
5-
A1
8. THIS BID ALTERNATE DRAWING SHALL REPLACED THE BASE BID DRAWING H-EL1.1FD5. REMOVE
DRAWING H-EL1.1FD5 FROM THE DRAWING SET.
1 NOT USED.
2 COORDINATE MOUNTING HEIGHT OF THE "HHC" FIXTURE WITH ARCHITECT.
3 DIMMER CONTROL FOR DIMMING SYSTEM CONTROLLING LIGHTING IN THIS
ROOM.
4 SEE POWER DRAWING H-EP1.1FD5 FOR THE CONNECTION OF PIT LIGHT.
5 INVERTER FOR WALL MOUNTED HID FIXTURES. INVERTER SHALL BE 3.0 KVA,
277V, SINGLE PHASE UNIT. TRANSFER TIME SUFFICIENT FOR HID LAMPS
REMAIN ILLUMINATED THROUGH THE TRANSFER. BATTERY TIME SHALL BE FOR
A MINIMUM OF 10 MINUTES.
6 NORMAL LIGHTING CIRCUIT SHALL BE CONTROLLED BY THE LIGHTING
CONTROL SYSTEM LOCATED IN ROOM 1B201a. SEE DRAWING H-EL6.001 DETAIL
# 7 FOR LIGHTING CONTROL DETAIL.
7 NOT USED.
8 CIRCUIT TO 120/208V PANEL H2D2LN2 CIRCUIT #19,21 LOCATED IN ELECTRICAL
ROOM 2N506.
9 20A, 3P CIRCUIT (5250W) TO 120/208V PANEL H1D5LN1 CIRCUIT #44,46,48.
10 DIMMER PANEL TO SERVE CANTEEN RETAIL ROOM 1N601. SEE LIGHTING
MATRIX ON DRAWING.
11 20A, 1P CIRCUIT (4437W) TO PANEL H1D5HN2 CIRCUIT # 7.
12 NOT USED.
13 SEE SHEET H-EL1.1FE2-A FOR CONTINUATION.
14 (2) 20A, 120/277V SINGLE POLE SWITCHES MOUNTED IN DEMOUNTABLE
PARTITION. MOUNT AT 48" AFF TO CENTER. COORDINATE WITH
MANUFACTURERS REQUIREMENTS FOR BACKBOX AND RACEWAY.
15 SEE TYPICAL CONFERENCE ROOM AUDIO/VISUAL RISER DIAGRAM DETAIL
2/H-ET5.505 FOR LIGHTING CONTROLS IN THIS AREA.
16 PROVIDE TWO WALL MOUNTED DIMMING SWITCHES FOR CONTROL OF THE
LIGHTING FIXTURES IN THIS ROOM IN THE EVENT THAT THE AUDIO/VISUAL
CONTROL SYSTEM IS NOT PROVIDED. COORDINATE WITH THE RESIDENT
ENGINEER. THE SWITCHES SHALL BE MOUNTED IN THE BOX ADJACENT TO THE
DOOR DESIGNATED FOR THE THE LOW VOLTAGE DIMMING CONTROLS.
17 SEE TYPICAL CONFERENCE ROOM AUDIO/VISUAL RISER DIAGRAM DETAIL
1/H-ET5.505 FOR LIGHTING CONTROLS IN THIS AREA.
D
D
D a a
D
D
D
D
D
HA3 HA3
HA3
HA3 HA3
HA3
HA3
HA11
HA3
HA3
HA3
HA3
HA11
HA3
HA3
HA3
HA3 HA3
HA3
HA3
HA3
HA3
HA3
HA3
HA3
HA3
HA3
HA3
HA1
HA1
HA1
HA1
HA11
HA11
HA3HA3
HA3
HA3
HA1
HA1
HA1
HA1
HA1
HA11
HA11
HA3HA3
HB1
HF4
HF4
HF4
HB5
HB1
HB5
HB1
HB5
HB5
HAC
HAC HAC
HAC
HP2
HP2
HP2 HP2
HP2 HP2
HP2
HP2
HP2
HP2
HP2
HP2
HP2
HP2
HB5
HF1
HF1
HA3
HA3
HA3
HA11
HA3
HW1
HW1
HW1
HW1
HW1 HW1
HB5
HB5HB5
HB5
HB5
HB5 HB5
HB5
HB5
HB5HB5
HB1
HW
HA3
HA11
HA3
HA3
HA3
HA3
HB1
HA3
HA11
HA3
HA11
HA3
HA11 HA11 HA11 HA11
HF1HF1
HB1
HB1
HB1 HB1 HB1 HB1
HB1
HB1 HW1
HW1
HW1
HW1
HA1
HA1
HA1
HA11
HF1
HA1
HB1
HB1
HB1
HB1
HA1
HA1
HA1
HA11HA1
HA1
HA3
HA3
HA3
HA3HA3
HA11
HA3
HA3
HA11
HA3
HA3
HA3
HA3
HA11
HA11
HA11
HA11
HA9HA9
HA3 HA3
HA3
HA3
HA3
HA9
HB5 HB5 HB5
HB5
HB1
HB1
HB1
HB1
HB1
HB1
HB1
HA3 HA11
HA11 HA3
HA3
HA3
HA11
HB1
HB1
HB1
HA1
HA3
HA3
HA11
HA11
HA11
HA11
HA2 HA3 HA3 HA3
HA11
HA11
HA11
HA11
HA11
HA11
HA11
HA11HE
HA11
HA3
HA3
HU
a a a,b a,b a,b a,b
HA11
HA11
HA11
HE
HU
HU
HB1
HB1
HU
HB5
HB5
HB5
HB5
HB1
HB1
HB1
HB1
HB1
HB1
HA1
HB1
HA11HA11
HB1
HA1
HB1
HB1
HB5
HA11
HA3
HA3
HA3
HA3
HA3HA3
HA3 HA3
HB5
HA3
HA9
HA3
HA3
HA11
HA11
HB1
HB1
HB1
HB5
HB1
HB5
HF2
HF3
HA1
HA1
HB1
HB1
HB1
HB1
HB1
HA3
a,b a,b a a,b a,b
HA3
HA3
HB5
HB5
a a a,b a a,b a,b a,b a,b a,b a a,b a,b a,b a,b a a a,b a,b a,b a,b a a a,b a,b a,b a,b a a a a,b a,b a,b a,b a,b a,b a a,b a,b a,b a,b a a,b a,b a a a,b a,b a,ba,b
D a a a,b a,b a,b a,ba a,b a,b a,b a,b a
HF1
HF1
HF1
HF1
HF1
HF1
HF1HU
a,b a,b a,b a,ba a,b a,b a a a,b a,ba,ba,b a a a,ba,b a,b a,b
H1E2HN1- 3
H1E2HN2- 1
H1E2HN2- 2
a,b
HB1
HW
a b a,b a,b a,b a,b a,b a,b a a b b
HB1
b b
HA9
b b b b b b b b b b b b b b b b b b b b b b b b b a,b a,b
HF1
a,b a,b a b
H1E2HN1- 2
H1E2HN1- 6
HA1
b
HE
HB1
HB1
HB1
HB1
HE
HE
HE
HE
HB1
HB1
HB1
HB1
HB1
HB1
HB1
HB1
HB1
HB1
HB1
HF1 HF1 HF1HF1 HF1 HF1
H1E2HN1- 4
H1E2HN1- 5
HE
HE
HB1
HB1
HB1HB1
HB1
HB1
H1E2HN2- 6
HU
HU
HU
HE
HE
HF2
HE HE
H1E2HS1- 6
H1E2HN1- 1
D
D
D
D
D
DD
D
D
D
D
D D
DD
D
D
D
D
D
DD
HP
HP
3 3
HA11
HP2 HP2 HP2 HP2 HP2 HP2
HB3
CORRIDOR
1CC09
INTERVIEW
1C201
INTERVIEW
1C203
H -E
L1 .1
FE
3-
A
H -E
L1 .1
FE
2-
A
H -E
L1 .1
FE
2-
A
H -E
L1 .1
FE
HAC
HAC
HAC
HB18
D
HA2
HA11 HA11 HA11 HA11
HA11HA11HA11HA11
HB1
HE
HB1
HB1
HB1
H1E2HN2- 7
c c c b b b a b
H1E2HS1- 7
b a
HB5
HF5 HF5
HE
HB18
HAC
HAC
HP1
HC9
HP1
D
D
D
D
D
D
D
D
U
HP1
HP1
HC9
HP1HP1HP1
HP1
HP1
HA1
HA1
HA1
b a a,b a,b a,b b a,b a,b a,b a,b
D
D a b a,b a,b a,b a b
DD
D
D
D
H1E2HN1- 9H1E2HS1- 8
H1E2HN1- 8
HU
HC9
c
D
HE
HF10
H1E2HC1- 1
HB5
HB5
D
HF10
HF10
HF10 HF10
HF10 HF10
HB6
HB1
HB1HB1
HB1HB1
HB1 HB1
HB6
D a,b,c
HB2
HB2
HB2
HU
HA11
H 1E
2H N
2-c D
D
JOB LAB
1C403
CORRIDOR
1CC04
VRE OFFICE
1C401
VRE OFFICE
1C604
CUBICLES
1C606
CORRIDOR
1CC06
VRE OFFICE
1C603
TESTING RM
1C110
PASSAGE
1C112
MAIL ROOM
1C112a
VRE OFFICE
1C908
CUBICLES
1C602
VRE OFFICE
1C904
VRE OFFICE
1C902
VRE
SUPERVISOR
1C901
VRE OFFICE
1C903
VRE OFFICE
1C905
VRE OFFICE
1C907
WAITING
1C102
RECEPTION
1C101 CORRIDOR
1CC02
HEARING RM
1C202
CORRIDOR
1CC01
CLOSET
1C106 HAC
1C108
CLOSET
1C104 c
H1E2HS1-5
HE2
HE
7.1
2.2
C.2
A.2
D.2
B.2
C.1
A.1
D.1
B.1
1.2
8.1
A
2.0
7.3
30.2
A.05
32.4
A.042.8
1.4
32333435 A7
6.7
7.7
B.3
A.01
35.4 31.7
A.02
32.8
A.03
33.8
A.07
U
3 3
HP HP
HF4
HP
HP
HP HP
c cc c cc c
HA1
D
HF10
HF10
HF10
HB1
U
U
HB1
HE
D
U
D
U
U
U
D c c
D
U
HB1
HB1
HB1
HB1
HB1
HB1
c c
D c c c c c c c
U
36 35 34 33 A7 32 31 30.2
B.3
B
A
D.1
C.1
A.1
6.7
7.17.3
7.7
8.1
A.04 A.03
A.02
31.7
32.4
32.833.8
34.2
34.4
34.5
35.4
1.2
1.4
2.02.2
2.8
A.2
B.2
C.2
D.2
D
U
U a,b a,b
HF1
HF1
HF1
HF1
3a,b a,b
D
D
D
D
HF1
HF1
HF1
a,b
HB3
HF4
HF4
HF4
a,b a,b
HF1
D
2 2
HF1
HF1
HF1
HF1 HF1
a,b
D a,b
HA9
D
D
H1E2HN2- 4
H1E2HS2- 11
HB1
c
HB1
c
HB1
c
HB1
c
HB1
c
HB1
c
HB1
c
HB1
c
HB1
c
HB1
c
HB1
c
HB1
HB1
HB1
c
HB1
c
HA11
b b b b
HA11 HA11 HA11
b b
HT1 HT1
H1E2LN2-30
a a
H1E2HS1- 3
HB1
HB1
HB1
H1E2HS1- 4
HB10
PUBLIC TLT
MALE
1B603
PUBLIC TLT
FEMALE
1B601
HAC
1B604
ELEC
1C102a
ADMISSIONS
CHECK IN
1B204
PROCEDURE
CHECK IN
1B205
ADMISSIONS
CHECK IN
1B202
PROCEDURE
CHECK IN
1B203
PHONE
1A501
ED TLT
FEMALE
1A504
ED TLT MALE
1A502
COMM
1B201b
ELEC
1B201a
MAS WORKRM
1B201
VENDING
1A121a
TRIAGE
1A718
TRIAGE
1A119
ISOLATION
1A721
ANTE RM
1A719
ISOLATION
1A717
OFFICE
1A801
OFFICE
1A803
PATIENT TLT
1A115
PHYSICIAN
1F507
CONSULT
1A124
PHYSICIAN
1F505
PHYSICIAN
1F503
FIRE
COMMAND
1B505
GYN EXAM/
TREAT
1A120
EXAM/TREAT
1A109c
GYN EXAM/
TREAT
1A122
EXAM/TREAT
1A109d
PATIENT TLT
1A714
EXAM/TREAT
1A715
SECURITY
SCREENING
1B403c
CORRIDOR
1BC06
PHONE
1B602
KIOSK
CHECK-IN
1BC04a
CORRIDOR
1BC02
CORRIDOR
1AC05
CORRIDOR
1BC03
CORRIDOR
1AC08
CORRIDOR
1BC07
ELEVATOR
LOBBY
1B405
ESCORT
SERVICES
1B701
OFFICE OF
DECEDENT
AFFAIRS
1B703
WAITING
1A121
OPERATIONS
1B303a
VESTIBULE
1B303
HOLDING
1B303b
CORRIDOR
1BC04
MECH
1B401b
VESTIBULE
1B401
WHEEL CHAIR
STOR
1B401a
RECEPTION
1B403a
LOBBY
1B403
VESTIBULE
1BCO1a
CORRIDOR
1BC05
ELEVATOR
1BE01
ELEVATOR
1BE03
ELEVATOR
1BE04
ELEVATOR
1BE02
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot
6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950Professional Seals:
EB / RLF of04 JUNE, 2010
BUILDING IS FULLY SPRINKLERED
01 AND 02
HOSPITAL/CLINIC
H-EL1.1FE2-A
LEVEL 1, AREA E, ZONE 2
LIGHTING PLAN BID ALTERNATE NO. 1
EB/RLF 3668
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
C1
D3
D4
E2
A2 A3
B1 B2
AREA E, ZONE 2
D2
D5 D6
E1 E3
D1
D7
CLINIC
HOSPITAL
P-W P-E
A4
E4
W
KEY NOTES:
GENERAL NOTES:
1. ELECTRICAL CONTRACTOR SHALL COORDINATE CEILING TYPE WITH FIXTURE FLANGE OR GRID TYPE
MOUNTING PRIOR TO INSTALLATION.
2. ALL UNDER COUNTER LIGHTING FIXTURES SHALL BE CIRCUIT TO NEAREST RECEPTACLE. A WALL SWITCH SHALL BE INSTALLED TO CONTROL UNDER CABINET LIGHTING FIXTURE. WHERE TWO OR MORE UNDER CABINET LIGHTING FIXTURES, TYPE "HU", SHALL BE CIRCUITED TO THE SAME CIRCUIT AND CONTROLLED BY THE SAME WALL SWITCH. MOUNTING LOCATION OF FIXTURES SHALL BE AT CENTER OF CABINETS.
3. LIFE SAFETY LIGHTING SHALL BE CONTROLLED BY CIRCUIT BREAKER IN LIFE SAFETY PANEL EXCEPT
WHERE INDICATED ON THE DRAWING.
5. ALL HOME RUNS SHALL BE ROUTED FROM THE DEVICE/FIXTURE INDICATED TO THE APPROPRIATE WIREWAY WITHIN THE INTERSTITIAL SPACE ABOVE. SEE 1/H-EP5.510 FOR INTERSTITIAL FLOOR
PENETRATION DETAIL.
7. THIS DRAWING IS FOR BID ALTERNATE AREA INFORMATION ONLY. REFER TO BASE BID DRAWINGS FOR SHELL
SPACES FOR THESE BID ALTERNATE AREAS AND BASE BID INFORMATION AND CIRCUITING.
H-EL1.1FE2-A
H-EL1.1FD5
1 NOT USED.
2 NOT USED.
3 SEE POWER DRAWING H-EP1.1FE2 FOR THE CONNECTION OF
ELEVATOR PIT LIGHT.
4 INVERTER FOR POLE MOUNTED LIGHTING FIXTURE IN LOBBY.
INVERTER SHALL BE 3.0 KVA, 277V SINGLE PHASE. TRANSFER
TIME SUFFICIENT FOR HID LAMPS TO REMAIN ILLUMINATED
THRU THE TRANSFER. BATTERY TIME SHALL BE FOR A MINIMUM
OF 10 MINUTES.
5 NOT USED.
6 NOT USED.
7 NORMAL LIGHTING CIRCUIT SHALL BE CONTROLLED BY THE
LIGHTING CONTROL SYSTEM LOCATED IN ROOM 1B201a. SEE
DRAWING H-EL6.001 DETAIL #7 FOR TYPICAL LIGHTING
CONTROL DETAILS.
8 NOT USED.
9 LIFE SAFETY LIGHTING CIRCUIT SHALL BE CONTROLLED BY THE
LIGHTING CONTROL SYSTEM LOCATED IN ROOM 1B201a. SEE
DRAWING H-EL6.001 DETAIL #7 FOR LIGHTING CONTROL DETAIL.
HOME RUN SHALL BE CIRCUITED THROUGHT THE INVERTER TO
ALLOW HID LAMPS TO REMAIN ON WHEN THE POWER TO THE
BUILDING GOES DOWN AND LIFE SAFETY CIRCUIT TRANSFERS
TO GENERATOR BACKED UP POWER.
10 CIRCUIT FOR IN GRADE LIGHTING FIXTURES "HP2" SHALL BE
CIRCUITED TO PANEL H1E2LN3 CIRCUIT #1 VIA LIGHTING
CONTROL PANEL IN ROOM -1B505 (FIRE COMMAND).
11 PROVIDE WALL PLATE WITH TAMPERPROOF SCREWS AND
BEVELED EDGES.
No. Description Date
3 CPR 112 07/15/2011
4 CPR 160 10/14/2011
5 CPR 319 08/02/2012
6 CPR 320 08/09/2012
7 CPR 333 09/06/2012
8 CPR 354 11/01/2012
9 CPR 366 11/20/2012
10 CPR 381 03/29/2013
4. OCCUPANCY SENSOR IN OFFICE SHALL BE THE DUAL TECHNALOGY TYPE WITH THE 20'x20' PATTERN (OR DESCRIPTION 3), UNLESS OFFICE IS LARGER THAN 20'x20'.
6. COORIDOR OCCUPANCY SENSOR SHALL BE THE ' ULTRASONIC ' TYPE WHEN SPACE MORE THAN 40' APART.
ALL CORRIDOR FIXTURES OF NORMAL CIRCUITRY SHALL BE CONTROLLED BY OCCUPANCY SENSOR LOCATED
IN SAME CORRIDOR, UNLESS OTHERWISE INDICATED BY SWITCH LEGS.
8. LOBBY - ACTIVATION OF THE FIRE ALARM SYSTEM SHALL BRING ALL LIGHTING ZONES TO FULL BRIGHT/ON.
9. THIS BID ALTERNATE DRAWING SHALL REPLACE THE BASE BID DRAWING H-EL1.1FE2.
THE DRAWING H-EL1.1FE2 SHALL BE REMOVED FROM THE DRAWING SET.
45 5
J
J
J
J
J
J
J
J J
J
M
J
J
J
J
J J
J
J J J
J
J
J
PP
PP
PP
PP
PP
PP
EE
J J
JJ
JJ
JJ
JJ
JJ
JJ
J
G
G
G
G
G
G
GG
G
G
G
G
G
G
G
G
H1E2LS1- 1,3
H1E2LC1- 2,4
H1E2LN1-
7,9,11
H1E2LN1- 4,6
H1E2LC1-
20,22
H1E2LC1- 15
H1E2LN1- 12
H1E2LN1-
15,17
H1E2LN1-
18,20
H1E2LN1-
21,23
H1E2LN1- 28
H1E2LN1-
24,26
H1E2LN2- 1,3
H1E2LN2- 2
H1E2LN2- 4
H1E2LN2- 5
H1E2LC1- 17
H1E2LN2- 6
H1E2LC3- 4
H1E2LN3- 2,4
H1E2LN3- 5,7
G
H1E2LN3- 12
H1E2LN3-
14,16
H1E2LN3-
13,15
G
H1E2LN3-
18,20
H1E2LN3-
17,19,21
H1E2LN3- 22
H1E2LN3-
24,26
H1E2LN3-
23,25
H1E2LN3-
28,30
H1E2LN4- 2,4
H1E2LN4- 5,7
H1E2LN4- 1,3
H1E2LN4- 6
H1E2LN4-
10,12
H1E2LC3- 1
H1E2LN4- 8
H1E3LN1- 1,3
H1E2LN4- 9
H1E2LN4- 14
H1E2LN4-
11,16
H1E2LN4- 13
H1E1LC2- 25
H1E1LN2-
16,14
H1E1LN2- 13
H1E2LC1- 5
H1E2LN2-
14,16
VRE OFFICE
1C908
H -E
P 1.
1F E
3- A
H -E
P 1.
1F E
2- A
H -E
P 1.
1F E
2- A
H -E
P 1.
1F E
H1E2LN1- 13
TV
TV
12H1E2LN2- 8
H1E2LN2- 10
H1E2LN3- 32
EX
EX
EX
H1E3LN1- 35
EX
EX
EX
G
G
8 8
G G
WAITING
1C102
CORRIDOR
1CC01
RECEPTION
1C101
HEARING RM
1C202
CLOSET
1C104
CLOSET
1C106
HAC
1C108
TESTING RM
1C110
INTERVIEW
1C203
JOB LAB
1C403
CUBICLES
1C606
CORRIDOR
1CC04
MAIL ROOM
1C112a
CORRIDOR
1CC02
INTERVIEW
1C201
VRE OFFICE
1C401
CORRIDOR
1CC06
VRE OFFICE
1C904
VRE OFFICE
1C902
VRE
SUPERVISOR
1C901
CORRIDOR
1CC09
ALCOVE
1CC09c
VRE OFFICE
1C903
VRE OFFICE
1C907
H1E2LN4- 18
H1E2LN1- 10
H1E2LN1- 14
H1D5LE3- 10
H1D5LE3- 9
EWC
H1E2LN1- 25
H1E2LS1- 11
H1E2LS1- 12
H1E2LS1- 13
7.1
2.2
C.2
A.2
D.2
B.2
C.1
A.1
D.1
B.1
1.2
8.1
A
B
2.0
7.3
30.2
A.05
32.2
A.04
2.8
1.4
32333435
A7
A7
6.7
7.7
B.3
A.01
35.4 31.7
D.3
A.02
32.8
A.03
33.8
A.07
0' - 4 1/2"
3' - 0"
H1E2LC3-
3,10
H1E2LN2- 22
H1E2LN2- 23
H1E2LN2- 24
7' - 9 1/2"
5' - 1"
14' - 3"
7' - 4"
17' - 6"
8' - 2 1/2"
3' - 11 1/2"
12' - 1"
9' - 7"
10' - 0"
3' - 8"
0' - 6 1/2"
+66"
OC OC
OC
OC
+66"
+48"
+48"
+48"
+48"
OC
OC
+66"
TV
OC
OC
OC
OC
H1E2LN4- 20
H1E2LN3-
8,10
H1E2LN3-
11,9
B
B
H1E2LS1- 10
H1E2LS1- 9
H-DVC
H-H-FACU
B
B
B
B
B
B B
17 19,21
H1E2LN1- 8
EWC
H1E2LN1- 16
H1E2LN1- 1
H1E2LS1- 8
H-FAAP
H-FCU-1.17
ST-H-FCU-1.17
+48"
+48"
H1E2LN1- 22
H1E2LN3- 31
G
G G
OC
H1E2LN2- 20
H1E2LN2-
13,11
H1E1LC2- 40
H1E1LN1-
19,21
H1E2LN4- 17
H1E2LC1- 26
H1E2LC1- 24
H1E2LC3- 6
H1E2LN1- 29
G +48"
OC
11 8
AUTOMATIC
DOOR
AUTOMATIC
DOOR
H1E2LN1- 19
H1E2LC1- 6,8
H1E2LC1-
12,14
H1E2LS1- 6
H1E2LC1- 1,3
H1E2LN2-26
H1E2LN2-27,29
P
H1E2LS1-14
H-EP4.007
25 27
H1E2LS2-1
H1E2LS2-3
H1E2LC1-
30,32
30 30
H1E2LC1- 7,9
TV
H1E2LN2-
18,15
33 H1E2LS1-17
N2 N1 E2 E1
N2 N1 E2 E1
N1N2
E2 E1
H1E2LC1- 29
H1E1LN2- 50
H 1E
3L N
1-
TR
PUBLIC TLT
MALE
1B603
PUBLIC TLT
FEMALE
1B601
HAC
1B604
ELEC
1C102aADMISSIONS
CHECK IN
1B204
PROCEDURE
CHECK IN
1B205
ADMISSIONS
CHECK IN
1B202
PROCEDURE
CHECK IN
1B203
PHONE
1A501
ED TLT
FEMALE
1A504
ED TLT MALE
1A502
ELEC
1B201aVENDING
1A121a
WAITING
1A121
TRIAGE
1A718
TRIAGE
1A119
ISOLATION
1A721ANTE RM
1A719
ISOLATION
1A717
OFFICE
1A801
OFFICE
1A803
PATIENT TLT
1A115
PHYSICIAN
1F507
CONSULT
1A124
PHYSICIAN
1F505
PHYSICIAN
1F503
FIRE
COMMAND
1B505
EQ. ALCOVE
1AC08a
GYN EXAM/
TREAT
1A122
PATIENT TLT
1A714
EXAM/TREAT
1A715
COMM
1B201b
MAS WORKRM
1B201
SECURITY
SCREENING
1B403c
CORRIDOR
1BC06
PHONE
1B602
KIOSK
CHECK-IN
1BC04a
CORRIDOR
1BC02
VESTIBULE
1B303
CORRIDOR
1BC03
CORRIDOR
1AC08
CORRIDOR
1AC05
LOBBY
1B403
ELEVATOR
1BE04
ELEVATOR
1BE02
EQ. ALCOVE
1AC08b
ELEC
1C102a
ELEC
1C102a
ELEC
1C102a
ELEC
1C102a
ELEVATOR
1BE03
HOLDING
1B303b
WAITING
1B403d
ESC…