ATTACHMENT - VOLUME 11C_Lighting Plans Updated 07.08.13-2.pdf
PDF 1 MB Posted
- Solicitation number
- 36C24825R0025-0001
About this file
This is a lighting plan drawing for Level 1, Area D, Zone 5 of a VA hospital/clinic facility. The architectural floor plan shows the detailed lighting layout including fixture types and locations throughout various medical spaces including radiology rooms, offices, corridors, waiting areas, and utility rooms. The drawing includes numerous technical annotations and symbols indicating different lighting fixture types (marked as HA1, HA2, HA3, etc.), control systems, and electrical specifications. Key spaces shown include general purpose X-ray rooms, digital archive areas, staff offices, patient waiting areas, and support spaces. The drawing contains general notes about electrical installation requirements, safety lighting specifications, and coordination notes for contractors. It appears to be part of a larger set of construction documents, with references to related drawings and specifications. The drawing is professionally sealed and shows multiple revision dates through 2013.
View the file
Other files
Show all 21
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
UP
DN
DD
D
D
GENERAL
PURPOSE/X-RAY
ROOM/(RAD
ROOM)
1M103
DIGITAL
ARCHIVE
1M604
TLT
1M302
SOILED HOLD
1M306 CLEAN UTILITY
1M308
CONCESSIONS
1M811
EMPLOYEE
BIO-SAFETY
1M307
RADIOLOGY
LOCKERS AND
TOILETS
1M303
COMM
1M403
OFFICE
(FDVA/STATE)
1N206
OFFICE
(FDVA/STATE)
1N204
OFFICE (VFW)
1N202
OFFICE
(FAVA/STATE)
1N205
OFFICE
(FDVA/STATE)
1N203
RECEP(FDVA/STATE)
1N201
OFFICE (PVA)
1N406
OFFICE (PVA)
1N404
OFFICE/RECEP(PVA)
1N402
OFFICE/ADMIN(DAV)
1N401
OFFICE (DAV)
1N403
OFFICE
1N405
LOCKERS
MALE
1G302a
TLT & SHWR
MALE
1G302b
RETAIL
STORAGE
1G304
TLT & SHWR
FEMALE
1G303b
HAC
1G305
EVIDENCE
STOR
1H206a
OFFICE(COUNTY)
1G101b
OFFICE(COUNTY)
1G101a
POLICE
TRAINING
ROOM
1H206
TRAINING
ROOM
1G408
CO-ORDINATOR
1G406
WAITING
1G404
STORAGE
1G410
OFFICE
1H204
SERVICE
OFFICER
1G401
CHIEF
1G403
OFFICE
1H202
OFFICE
1H203
CLERICAL
1H201
ECG CUBICLE
1F104
STRESS
LAB/ECHO
1F604
STRESS
LAB/ECHO
1F602
STAFF TLT
1F402
TLT
1F403
HAC
1F401
STORAGE
1F101
ECG: CUBICLE
1F408
ECG CUBICLE
1F406
PHYSICIAN
1F303
PHYSICIAN
1F301
PACEMAKER/HOLTER
MONITOR
ROOM
1F307
CHIEF
NON-INVASIVE
1F203
UNASSIGNED
1F309
ECG/ECHO
READING
1F601
ECHO ROOM
1F605
ECG ROOM
1F106
STRESS LAB
1F607
PATIENT
STORAGE
1F716a
RAD/FLOURO
1M708
PACS OFFICE
1M406
ADPAC OFFICE
1M404
BIO MED
OFFICE
1M204
CONFERENCE
1M718
RF TLT
1M712
RF TLT
1M706
CHIEF OF
CARDIOLOGY
1M715
SECRETARY
1M717
GENERAL
PURPOSE/X-RAY
ROOM/(RAD
ROOM)
1M105
TECH WORK
1M210
ELEC
1N601a
CORRIDOR
1MC07
WAIT
1M702
CHEST RM
1M206
CHIEF TECH
OFFICE
1M402
CANTEEN
RETAIL
1N601CORRIDOR
1MC03
PASSAGE
1MC04
CORRIDOR
1MC06
CONTROL
1M103a
COMM
1N601b
CORRIDOR
1NC04
PASSAGE
1NC02
CORRIDOR
1GC03
WAITING/LOUNGE
1G101
STAIR
1ES01
ELEV LOBBY
1GC02
COFFEE SHOP
1F808
WORK
1F808a
CORRIDOR
1FC06
PATIENT REP
1F806
ELEC
1F802
ELEVATOR
LOBBY
1F716
PASSAGE
1HC02
VESTIBULE
1G303
CORRIDOR
1FC04
DETECTIVE
OFFICE
1H410
DRESS
1M714
CORRIDOR
1MC08
SECRETARY
1G402VEST
1F201
PATIENT REP
1F804
PUBLIC TLT
1F808b
CORRIDOR
1MC02
TECH WORK
1M210
CORRIDOR
1FC03
CORRIDOR
1FC05
ELEVATOR
1EE02
ELEVATOR
1EE01
ELEVATOR
1FE03
ELEVATOR
1FE01
CORRIDOR
1FC07
LOCKERS
FEMALE
1G303a
VESTIBULE
1G302
CORRIDOR
1FC08
PHYSICIAN
1F505
PHYSICIAN
1F503
CONTROL
1M206a
HAC
1G304a
OFFICE
1H206b
OFFICE
1H206c
CORRIDOR
1FC02
303136
1.2 8.1
C
D
E
F
G
D.9
30.235.2
D.7
F.4
E.4
C.7
1.4
32333435 A7
7.7
32.532.7
33.6
K.8
K.9 a
D D
D
D
D
D
D
D
D
D
D
D
D
D D D D
D
D
D
D
D
HA2
HA11
HF10
HA1
HA3
HA1
HA3
HA11
HA3
HA3
HA3
HA2
HA2 HA3
HA1
HA2
HF1
HA1
HA3
HA3
HF1
HA3
HA3
HA1
HA3
HA3
HA2
HA3
HA3
HA3
HA3
HA3
HA1
HA3
HA2
HA1
HA3
HA3
HA3
HA3 HA3
HA3
HA11 HA11 HA11
HA11
HA2
HA2
HA2
HA3
HA3 HA3
HA3
HF10
HF10
HA3
HA3
HA3
HA3
HA3
HA3
HA11
HA11
HA1 HA1 HA3
HA3
HA11
HA3 HA3
HA11
HA11HA11 HA11HA11
HA11
HA11 HA11
HA3
HA1HA1
HA1
HB2 HB2 HB2
HB2HB2HB2HB2
HA1 HA1 HA1
HA3 HA3
HA3
HA3 HA3
HA11
HA11
HA3
HA3 HA3
HA11
HA3
HA3
HA3 HA3
HA11
HA3
HA3
HA3
HA11
HA3
HA3
HA3
HA3
HA1 HA1 HA1
HA2
HA2 HA2
HA2
HA2HA1
HB1
HB1
HB1
HA2
HA2
HA2
HA1HA1 HA1
HA2
HA3
HA3
HA3
HA3
HA3
HA3
HA3
HA3
HB2 HB2
HB2 HB2
HB2
HA2
HB2
HA9
HA9
HA1
HA1
HA1
HA1
HA3
HA3
HA3
HA3
HA3
HA3 HA3
HA3
HA3HA3 HA3
HA3
HA3
HA3
HA1 HA1 HA1 HA1 HA1 HA1
HB2
HB2 HB2 HB2
HB2 HB2
HB2
HB2 HB2
HB2 HB2
HB2
HA1 HA1
HA2
HA9 HA9 HA9
HA9
HA9 HA9
HA1
HA1
HA1HA1
HA9
HA9HA9
HA9
HA9
HA3
HA3
HA2
HA2
HA2
HA3HA3HA3
HA9HA9
HA9
HA9
HA9
HA3
HA3HA3HA3 HA3
HA3
HA1HA1HA1
HA9
HB2
HB2
HB2
HA3
HA9 HA9
HB2
HB2
HB2
HB2
HB2
HB2 HB2
HB2
HA9
HA9
HA9
HA9
HA9
HA3
HA3
HA3
HA3
HA3
HA1
HA1
HA3
HA11
HA1
HA3
HA1
HA11
HA3
HA3
HA3
HB1 HB1
HA1 HA1
HA3
HF10 HF10
HA3
HHC
HHC
HW2
HW2
HA2HA2
HA3
HA3
HA1
HA1
HB1
HB1
HW
HB1
HW
HA1
HA1
HA1
HA1
HB1
HW
HA14
HB1 HB1
HU
HU
HU
a a,b a,b a,b a,b a,b a,b a a a a,b a,b a a,b a,b a,ba,b a,b a
HU
HU
a
HF1
HWHW
HB1 HB1 HB1
HA11
HA1 HA1 HA1 HA1
HA1
HA3
HU
HU
HU
HU
HU
HA3
HU
HU HU
a a,b a,b a,b
HU
HU HU
g
HB1
HW
HU
b b b b b bbb a a a a a,b a,b a,b a,b a a a,b a,b a a a,b a,ba,ba,b
HU
a a,b a,b
HU
HU
a a a,b a,ba,ba,ba,b a,b
HB2HB2
HB2
HB2
a,b a,b a a a,b a,b a,b a,ba,b
D a a a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,b a,ba,b a,b a,b a a a a a a a a a a a a a a a,ba,b a,b a,b aa,b a,b a a,b a,b a,b a,b a a a a,ba,b a,b a,b a,b a,b a a a,b a,b a,b a,b a a,b a,b a,b a,b a a,ba,b a,b a,b a,b a,ba,b
HA3
HA3
b c c cc c a,b a,b c c
D
HB1
HB1
HB1
HW
HW
HF1
HF1
HF2
HF3
a
HB1
HW
DD
H1D5HN1- 2
H1D5HN1- 3
HB1
H1D6HN2- 4
a,b a,b a,b a a,ba,b a,b a,b a,b b b b b ee ff ff f ff a a aa a a a a c c c c
D Df aDc3e 3b
D b
HB2 b bb
HB1
b b b
HB1
b b b b bb b
HB1
b
HB1
b b b b b b b b b b a b b b b b b b bb b b b b b
HB1
b b b
HW
b
H1D5HN3
b a,b
HE
HB2
D
H1D5HN2- 3
HA1
HA1
H1D5HN2- 1
H1D5HN1- 4
H1D5HN1- 1
H1D5HN1- 6
H1D5HN2- 4 H1D5HN2- 9
HF9
HF9HF8
b
HA3
HUHW
HA9HA9HA9HA9
HA9
HA9HA9HA9HA9
HA9 HA9 HA9
HA9HA9 HA9 HA9
HA9 HA9
HA9 HA9
HA9 HA9
HA9
HA9
HA9 HA9
HA9
HA9HA9
HA9
HA9 HA9 HA9
HA9HA9
HA9 HA9
HA9HA9
HA9
HA9
HA9
HA9
HA9
HA9HA9
HA9
HA9
HA9
HA9HA9
HA9HA9
HA9
HA9
HA9
HA9 HA9
HA9 HA9
HA9HA9
HA9
HA9
HA9
HA9
HA9
HA9 HA9 HA9
HA9
HA9HA9
HA9HA9HA9
HA9
HA9
HA9
HA9 HA9 HA9 HA9
HA9
HA9
HA9
HA9
HA9HA9HA9HA9
D
D D
D
D
D
D
HU
HA9
HA9
H1D5HN3- 1
HA3
a,b
D
HE
D
D D
D
D
D
D
D
D
D
D D
D
D
D D
D D
D
D
HT1
HT2HT2
H1D5HC1- 3
D D
D
D
D D
D
D
D
D
D
D
D
HA2
H1D5HN2- 6
D
HB2
HB2
HA9
a
UP TO 3RD FLOOR CKT.
TYPICAL.
HA9
HT1 HT1 HT1
ZONE KZONE I
ZONE G,H
ZONE J
ZONE E,F
DOWN
UP
UP
UP
DOWN
DOWN
HW2
HP
HP
D b D a a a a a b b b b b b b b b b a a a a a
U
HT3
HT3
2 3
D
D
D a
D
D
D
H1D5HC1- 1
HB1 HB1
HB1
H1D5HC1- 2
D
H1D5HN2- 7
U
HU
HU
D D
HE
HA9HA9HA9
HA9 HA9
HA9
HA9
HA9 HA9
HE
HE
HA2
HA1
HA2
HF10
HF10
HF10 HF10
HA11
HA1
HE
HA1HA1
HA1
HA1
HE
HE
HA1
HA1HA1
HA1 HA1 HA1 HA1
HA1
HA1
HA1
HA1
HA1
HA1
HA1
HA11
HA11HA11
HA11
HA3
HA3
HE
HA3
HE
HA11
HE
HE
HE
H1E2HS1-2
HB16 HB16
HE
H1E2HS2-2
HB1
HB1
HA11
HA11
HE
HE
HE
HB1
HE
HB1
HA11
HA11
HE
HE
HE
HA1
H1E2HS2-7
HE
H1E2HS2-9
HE
HE
HE
HB5
HB5
HB1 HB1
HB1 HB1
HB1HB1
HB1 HB1
HB1 HB1
HE
HB19 HB19HB19
HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19 HB19
HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19HB19
HB1
HB1
H1E2HN1-10
HB6
HT2 HT2HT2HT2
HT1
HT2
HT2
HU HU
HU
HU g g
HP
HP
HUHU
HB2
HB2
HU
HU
HU
HF1 HF1
HB1
HU
HU
HU
HB2
HU
a,b b b b b b b
3 3 a a a bb b
D a bbb b
D
HU HUc c c c c c a a a a a a a a a a a a a 1 b b
HU
d d d d d d e e e a,b ccc b b bb a a a a a a aa a a a a aa b b a,b c c c b a a c c c cc a,b a,b a a a a e e e e e d d d d d b b b b b b b b a a a a a,b D f d d f f f f gHU HU HU a b c c a,b b b b b a a
HA9
HA9
HA9
d
HA2
HA2
U a a a
U
U
U
U
U
U b
U
U
U
U
U
U
U
UU
HB6
HU
d
H B
HB2
HB2
HB2
H B
HB2
HB2
HB2
HB2
HA9
HA9
HA9
HA9
HB2
HB2
b b b b a a a c a a a a aaa a3b cDD
D
D c c c c c
HE
RAD/FLOURO
1M710
CONTROL
1M710a
MAIL ROOM
1C112a
HA3
a,b
HA3
a,b
HA3
a,b
D
D a b a b
HA3
a,b
HB1 HB1
HA1
a
HF10
16D
16D
HB2
HB2
a
3e
3b 3b d
HU
d
HB2 a
HB2
a
D
Drawing Title
Approved: Project Director
Project Title
Date
Location
Checked
Building Number
Project Number
Drawing Number
Drawn
Dwg.
CONSULTANTS: ARCHITECT/ENGINEERS:
OFFICE OF
FACILITIES
MANAGEMENT
on e ei gh th in ch o ne fo ot
B
A
C
D
E
F th re e in ch es o ne fo ot
6"
6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot
6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r in ch o ne fo ot
VA FORM 08-6231, OCT 1978
1 2 3 4 5 6 87 9
F
E
D
C
B
A
97 8654321
A NEW HOSPITAL FOR
VAMC ORLANDO, FLORIDA
Orlando, Florida
673-950Professional Seals:
EB / RLF of04 JUNE, 2010
BUILDING IS FULLY SPRINKLERED
01 AND 02
HOSPITAL/CLINIC
H-EL1.1FD5-A
LEVEL 1, AREA D, ZONE 5
LIGHTING PLAN BID ALTERNATE NO. 1
EB/RLF 3662
N
1/8" = 1'-0" GRAPHIC SCALE
4' 8' 24'16'
A1
C2
KEY PLAN
AREA D, ZONE 5
C1
D3
D4
E2
A2 A3
B1 B2
D2
D5 D6
E1 E3
D1
D7
CLINIC
HOSPITAL
P-W P-E
A4
E4
W
KEY NOTES:
H -E
L1 .1
FD
5-
A
H -E
L1 .1
FD
H-EL1.1FE2-A
H-EL1.1FD5-A
No. Description Date
4 CPR 122 09/16/2011
5 CPR 178 11/07/2011
6 CPR 219 01/16/2012
7 CPR 236 03/09/2012
8 CPR 272 04/30/2012
9 CPR 319 08/02/2012
10 CPR 323 08/16/2012
11 CPR 373 01/24/2013
GENERAL NOTES:
1. ELECTRICAL CONTRACTOR SHALL COORDINATE CEILING TYPE WITH FIXTURE FLANGE OR GRID TYPE
MOUNTING PRIOR TO INSTALLATION.
2. ALL UNDER COUNTER LIGHTING FIXTURES SHALL BE CIRCUITED TO NEAREST RECEPTACLE. A WALL SWITCH SHALL BE INSTALLED TO CONTROL UNDER CABINET LIGHTING FIXTURES. WHERE TWO OR MORE UNDER CABINET LIGHTING FIXTURES, TYPE "HU", SHALL BE CIRCUITED TO THE SAME CIRCUIT AND CONTROLLED BY THE SAME WALL SWITCH. MOUNTING LOCATION OF FIXTURES SHALL BE AT CENTER OF
CABINETS.
3. LIFE SAFETY LIGHTING SHALL BE CONTROLLED BY CIRCUIT BREAKER IN LIFE SAFETY PANEL EXCEPT
WHERE INDICATED ON THE DRAWING.
4. OCCUPANCY SENSOR IN OFFICE SHALL BE THE DUAL TECHNOLOGY TYPE WITH THE 20'x20' PATTERN (OR DESCRIPTION 3), UNLESS OFFICE IS LARGER THAN 20'x20'.
5. ALL HOME RUNS SHALL BE ROUTED FROM THE DEVICE/FIXTURE INDICATED TO THE APPROPRIATE WIREWAY WITHIN THE INTERSTITIAL SPACE ABOVE. SEE 1/H-EP5.510 FOR INTERSTITIAL FLOOR
PENETRATION DETAIL.
6. CORRIDOR OCCUPANCY SENSORS SHALL BE THE ' ULTRASONIC ' TYPE WHEN SPACE MORE THAN 40' APART. ALL CORRIDOR FIXTURES OF NORMAL CIRCUITRY SHALL BE CONTROLLED BY OCCUPANCY
SENSOR LOCATED IN SAME CORRIDOR, UNLESS OTHERWISE INDICATED BY SWITCH LEGS.
7. CIRCUIT ALL IN-USE LIGHT "HN2" TO 120V CIRCUIT SERVING THE RESPECTIVE IMAGING SUITE AND CIRCUIT PER IMAGING EQUIPMENT MANUFACTURERS RECOMMENDATIONS. (CIRCUIT FROM RADIOLOGY EQUIPMENT)
1 1
H -E
L1 .1
FD
H -E
L1 .1
FD
5-
A1
8. THIS BID ALTERNATE DRAWING SHALL REPLACED THE BASE BID DRAWING H-EL1.1FD5. REMOVE
DRAWING H-EL1.1FD5 FROM THE DRAWING SET.
1 NOT USED.
2 COORDINATE MOUNTING HEIGHT OF THE "HHC" FIXTURE WITH ARCHITECT.
3 DIMMER CONTROL FOR DIMMING SYSTEM CONTROLLING LIGHTING IN THIS
ROOM.
4 SEE POWER DRAWING H-EP1.1FD5 FOR THE CONNECTION OF PIT LIGHT.
5 INVERTER FOR WALL MOUNTED HID FIXTURES. INVERTER SHALL BE 3.0 KVA,
277V, SINGLE PHASE UNIT. TRANSFER TIME SUFFICIENT FOR HID LAMPS
REMAIN ILLUMINATED THROUGH THE TRANSFER. BATTERY TIME SHALL BE FOR
A MINIMUM OF 10 MINUTES.
6 NORMAL LIGHTING CIRCUIT SHALL BE CONTROLLED BY THE LIGHTING
CONTROL SYSTEM LOCATED IN ROOM 1B201a. SEE DRAWING H-EL6.001 DETAIL
# 7 FOR LIGHTING CONTROL DETAIL.
7 NOT USED.
8 CIRCUIT TO 120/208V PANEL H2D2LN2 CIRCUIT #19,21 LOCATED IN ELECTRICAL
ROOM 2N506.
9 20A, 3P CIRCUIT (5250W) TO 120/208V PANEL H1D5LN1 CIRCUIT #44,46,48.
10 DIMMER PANEL TO SERVE CANTEEN RETAIL ROOM 1N601. SEE LIGHTING
MATRIX ON DRAWING.
11 20A, 1P CIRCUIT (4437W) TO PANEL H1D5HN2 CIRCUIT # 7.
12 NOT USED.
13 SEE SHEET H-EL1.1FE2-A FOR CONTINUATION.
14 (2) 20A, 120/277V SINGLE POLE SWITCHES MOUNTED IN DEMOUNTABLE
PARTITION. MOUNT AT 48" AFF TO CENTER. COORDINATE WITH
MANUFACTURERS REQUIREMENTS FOR BACKBOX AND RACEWAY.
15 SEE TYPICAL CONFERENCE ROOM AUDIO/VISUAL RISER DIAGRAM DETAIL
2/H-ET5.505 FOR LIGHTING CONTROLS IN THIS AREA.
16 PROVIDE TWO WALL MOUNTED DIMMING SWITCHES FOR CONTROL OF THE
LIGHTING FIXTURES IN THIS ROOM IN THE EVENT THAT THE AUDIO/VISUAL
CONTROL SYSTEM IS NOT PROVIDED. COORDINATE WITH THE RESIDENT
ENGINEER. THE SWITCHES SHALL BE MOUNTED IN THE BOX ADJACENT TO THE
DOOR DESIGNATED FOR THE THE LOW VOLTAGE DIMMING CONTROLS.
17 SEE TYPICAL CONFERENCE ROOM AUDIO/VISUAL RISER DIAGRAM DETAIL
1/H-ET5.505 FOR LIGHTING CONTROLS IN THIS AREA.
File details come from the government source that posted it. Updated .