Attachment L - Emerson EMS Inspection Report.pdf
PDF 5 MB Posted
- Solicitation number
- RFP DET 270000000151 2
- Issued by
- Wayne County, Detroit City, Michigan
About this file
This is an Emerson EMS Inspection Report prepared for Detroit Public Schools' Ralph W. Emerson Elementary/Middle School located at 18240 Huntington Road, Detroit, Michigan, dated June 10, 2026. The visual roof inspection conducted on May 12, 2026, assessed the remaining surface life of the existing roof system across 31 distinct roof areas (A through EE). The inspection identified multiple roof system types, including fully-adhered TPO membranes installed in 2017, 4-ply hot asphalt systems installed prior to 1999, a 45-mil EPDM membrane installed in 2019, and smooth surface 4-ply systems with aluminum coating from prior to 1999. The report documents significant structural deficiencies including ponding water caused by lack of slope, wet cores, membrane deterioration, flashing failures, fire damage, and drainage issues across multiple roof areas.
The inspection recommends full roof replacement for 24 roof areas (E, F, G, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Z, AA, BB, CC, DD, and EE) with removal of existing systems down to structural steel deck and installation of R-30 Insulation systems with fully-adhered 60-mil EPDM membranes eligible for a 20-year warranty at an estimated cost of $675,000. For the remaining six roof areas (A, B, C, D, H, and Y), aggressive preventative maintenance is recommended at an estimated cost of $10,000. The total estimated construction cost for all recommended work is $685,000. This inspection report supports the related state contract opportunity 27-0052 FMP Series 6 Roof Replacement for Cass Tech, Emerson in Michigan.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Detroit Public Schools – Ralph W. Emerson
Elementary/Middle School 18240 Huntington Road
Detroit, MI 48219
June 10, 2026
Detroit Public Schools – Ralph W. Emerson Elementary/Middle School
Table of Contents
Executive Summary Page 3
Roof Plan Page 4
Roof Area Descriptions Page 5
Roof Area Photos Page 16
EXECUTIVE SUMMARY
On May 12, 2026 a visual inspection of the existing roof system was performed. The purpose of this inspection was to determine the estimated surface life left of the existing roof system. Roof
Areas A, B, C, D, E, H, I, J, K, L, M, N, O & Z existing systems consisted of a fully-adhered TPO.
Roof Areas F, G, P, Q, S, T, W, X, Y, AA, BB, CC & EE existing systems consisted of a 4-ply in hot asphalt with an aggregate surface system installed prior to 1999. Roof Area R existing system consisted of a fully-adhered 45-mil EPDM roof membrane installed in 2019. Roof Areas U, V, & DD existing system consisted of the smooth surface 4-ply with a aluminum coating, installed prior to
1999.
Note: TPO areas are failing due to ponding water caused by lack of slope. Many of the cores taken were wet.
Recommendations:
Roof Areas E, F, G, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Z, AA, BB, CC, DD & EE: Remove existing roof systems system down to the structural steel deck. Install a R-30 Insulation system with a fully-adhered 60-mil EPDM membrane. This system is eligible for a 20 year warranty.
Roof Areas A, B, C, D, H & Y: Aggressive preventative maintenance
Estimated Construction Costs:
Roof Areas E, F, G, I, J, K, L, M, N, O, P, Q, R, S, T, U, V, W, X, Z, AA, BB, CC, DD & EE: Full replacement with a R-30 Insulation System with a fully-adhered 60-mil EPDM: $675,000.00
Roof Areas A, B, C, D, H & Y: Aggressive preventative maintenance $10,000.00
ROOF PLAN:
Note: Remaining life of existing roof systems is based on the estimated age of the roofs, visual inspection and assuming no maintenance being performed. Preforming repairs to roof areas that are red will not add any years to the roof life. It will only stop the current problem.
ROOF AREA DESCRIPTIONS:
Roof Area ID: A
Size: 3,100 sf.
Year Installed: 2017
Height: 30 ft
Structural Slope: None
Drainage: Roof Drain
Roof Area ID: B
Size: 4,143 sf.
Year Installed: 2017
Height: 32 ft
Drainage: Eave Edge
Roof Area ID: C
Size: 5,024 sf.
Year Installed: 2017
Height: 30 ft
Roof Area ID: D
Size: 1,751 sf.
Year Installed: 2017
Height: 20 ft
Roof Area ID: E
Size: 1,625 sf.
Year Installed: 2017
Height: 27 ft
Roof Area ID: F
Size: 1,231 sf.
Year Installed: Pre 1999
Height: 155 ft
Structural Slope: 1/8-Inch
Roof Area ID: G
Size: 65 sf.
Year Installed: Pre 1999
Height: 16 ft
Roof Area ID: H
Size: 2,399 sf.
Year Installed: 2017
Height: 22 ft
Roof Area ID: I
Size: 3,672 sf.
Year Installed: 2017
Height: 30 ft
Roof Area ID: J
Size: 2,832 sf.
Year Installed: 2017
Height: 32 ft
Drainage: Eave
Roof Area ID: K
Size: 3,000 sf.
Year Installed: 2017
Height: 30 ft
Roof Area ID: L
Size: 3,176 sf.
Year Installed: 2017
Height: 32 ft
Roof Area ID: M
Size: 2,250 sf.
Year Installed: 2017
Height: 30 ft
Roof Area ID: N
Size: 2,488 sf.
Year Installed: 2017
Height: 30 ft
Roof Area ID: O
Size: 2,514 sf.
Year Installed: 2017
Height: 30 ft
Roof Area ID: P
Size: 1,251 sf.
Year Installed: Pre 1999
Height: 12 ft
Drainage: Roof Drains
Roof Area ID: Q
Size: 3,405 sf.
Year Installed: Pre 1999
Height: 20 ft
Drainage: Roof Drains
Roof Area ID: R
Size: 404 sf.
Year Installed: 2017
Height: 12 ft
Roof Area ID: S
Size: 418 sf.
Y Year Installed: Pre 1999
Height: 15 ft
Drainage: Gutter
Roof Area ID: T
Size: 102 sf.
Year Installed: Pre 1999
Height: 12 ft
Roof Area ID: U
Size: 288 sf.
Year Installed: Pre 1999
Height: 15 ft
Roof Area ID: V
Size: 288 sf.
Year Installed: Pre 1999
Height: 15 ft
Roof Area ID: W
Size: 165 sf.
Year Installed: Pre 1999
Height: 12 ft
Roof Area ID: X
Size: 555 sf.
Year Installed: Pre 1999
Height: 12 ft
Roof Area ID: Y
Size: 68 sf.
Year Installed: Pre 1999
Height: 37 ft
Roof Area ID: Z
Size: 112 sf.
Year Installed: 2017
Height: 37 ft
Roof Area ID: AA
Size: 304 sf.
Year Installed: Pre 1999
Height: 15 ft
Roof Area ID: BB
Size: 440 sf.
Year Installed: Pre 1999
Height: 15 ft
Roof Area ID: CC
Size: 102 sf.
Year Installed: Pre 1999
Height: 12 ft
Structural Slope: 1/8
Roof Area ID: DD
Size: 186 sf.
Year Installed: Pre 1999
Height: 15 ft
Roof Area ID: EE
Size: 418 sf.
Year Installed: Pre 1999
Height: 15 ft
ROOF AREA PHOTOS:
Ponding water due to lack of slope
Hole caused by fire on roof
Hole caused by fire on roof
Open flashing
Split in drain pan flashing
Severe membrane deterioration
Split in drain pan flashing Open flashing lap
Open flashing lap
Membrane deterioration
Water behind flashing Membrane holes
File details come from the government source that posted it. Updated .