Attachment K - Clippert Academy Inspection Report.pdf

PDF 3 MB Posted

Attached to
27-0052 FMP Series 6 Roof Replacement for Cass Tech, Emerson
Solicitation number
RFP DET 270000000151 2
Issued by
Wayne County, Detroit City, Michigan

About this file

This is a roof inspection report for Detroit Public Schools' Clippert Multicultural Magnet Honors Academy located at 1981 McKinstry Street in Detroit, Michigan, conducted on May 20, 2026. The inspection assessed nine roof areas (A through I) totaling approximately 27,652 square feet to determine remaining surface life and establish replacement recommendations. The existing roof systems vary in age and composition, with some areas installed prior to 1999, others in 2004, and one area newly installed in 2024. Full roof replacement is recommended for Area A, while Areas B, C, D, E, F, and G require complete removal and installation of R-30 insulation systems with fully-adhered 60-mil EPDM membranes eligible for 20-year warranties. Areas D, H, and I require preventative maintenance only.

Total estimated construction costs are $458,000.00, comprised of $115,000.00 for Area A roof replacement with asphalt shingles, $340,000.00 for replacement of Areas B through G with R-30 insulation and EPDM systems, and $3,000.00 for preventative maintenance on Areas D, H, and I. The inspection identifies severe deterioration across multiple roof areas including deteriorated shingles, membrane blisters, failed flashing, and open flashing conditions. The report notes that remaining life estimates are based on roof age, visual inspection findings, and the assumption that no ongoing maintenance will be performed.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Detroit Public Schools – Clippert Multicultural Magnet Honors

1981 McKinstry Street Detroit, MI 48209

June 10, 2026

Detroit Public Schools – Clippert Multicultural Magnet Honors

Table of Contents

Executive Summary Page 3

Roof Plan Page 4

Roof Area Descriptions Page 5

Roof Area Photos Page 8

EXECUTIVE SUMMARY

On May 20, 2026 a visual inspection of the existing roof system was performed. The purpose of this inspection was to determine the estimated surface life left of the existing roof system. Roof

Area A existing system consisted of an asphalt granular surface architectural style shingle installed prior to 1999. Roof Areas B, C & E existing systems consisted of a modified bitumen granular surface system installed prior to 1999. Roof Area D existing system consisted of a fully-adhered

EPDM membrane installed in 2024. Roof Areas F & G existing systems consisted of a 4-ply aggregate surface BUR membrane installed in 2004. Roof Areas H & I existing systems consisted of an asphalt granular surface architectural style shingle installed in 2004.

Recommendations:

Roof Areas A: Full-replacement.

Roof Areas B, C, D, E, F & G: Remove existing roof systems system down to the structural steel deck. Install a R-30 Insulation system with a fully-adhered 60-mil EPDM membrane. This system is eligible for a 20 year warranty.

Roof Areas D, H & I: Preventative maintenance

Estimated Construction Costs:

Roof Area A: Full-replacement with new asphalt shingles: $115,000.00

Roof Areas B, C, D, E, F & G: Full replacement with a R-30 Insulation System with a fully-adhered 60-mil EPDM: $340,000.00

Roof Areas D, H & I: Preventative maintenance: $3,000.00

ROOF PLAN:

Note: Remaining life of existing roof systems is based on the estimated age of the roofs, visual inspection and assuming no maintenance being performed. Preforming repairs to roof areas that are red will not add any years to the roof life. It will only stop the current problem.

ROOF AREA DESCRIPTIONS:

Roof Area ID: A

Size: 9,000 sf.

Year Installed: Pre 1999

Height: 40 ft

Structural Slope: 10:12

Drainage: Roof Drains

Roof Area ID: B

Size: 3,268 sf.

Year Installed: Pre 1999

Height: 50 ft

Structural Slope: 1/8-Inch

Drainage: Eave

Roof Area ID: C

Size: 144 sf.

Year Installed: Pre 1999

Height: 51 ft

Roof Area ID: D

Size: 1,432 sf.

Year Installed: 2024

Height: 25 ft

Structural Slope: Min. 1/8”

Drainage: Gutter

Roof Area ID: E

Size: 192 sf.

Year Installed: Pre 1999

Height: 35 ft

Structural Slope: 1/4-inch

Roof Area ID: F

Size: 7,327 sf.

Year Installed: 2004

Height: 15 ft

Structural Slope: Min. 1/8”

Drainage: Roof Drains

Roof Area ID: G

Size: 4,389 sf.

Year Installed: 2004

Height: 25 ft

Roof Area ID: H

Size: 1,000 sf.

Year Installed: 2004

Height: 10 ft

Structural Slope: 5:12

Roof Area ID: I

Size: 900 sf.

Year Installed: 2004

Height: 10 ft

Structural Slope: 5:12

ROOF AREA PHOTOS:

Severe deterioration

Deteriorated shingles

Severely deteriorated shingles

Membrane blister

Severely deteriorated membrane

Open flashing

Failed flashing

Improperly flashed

File details come from the government source that posted it. Updated .