Attachment C - Cass Tech HS Drawings.pdf
PDF 3 MB Posted
- Solicitation number
- RFP DET 270000000151 2
- Issued by
- Wayne County, Detroit City, Michigan
About this file
This file consists of architectural drawings and technical specifications for a roof replacement project at Cass Technical High School in Detroit, Michigan, prepared for Detroit Public Schools. The project involves the complete replacement of existing roofing systems across multiple roof areas (A-W) totaling approximately 103,914 square feet. The scope of work includes removal of existing roof membranes down to the structural deck, inspection and repair of structural components, installation of a tapered polyisocyanurate insulation system with a base layer of 2.5 inches and tapered coverage providing 1/8-inch per foot slope, installation of a 1/2-inch high-density polyiso cover board, and application of a fully-adhered 60-mil EPDM roofing membrane with 6-inch seams. The project also requires replacement of roof drainage components, flashing materials, sealants, and coordination with existing rooftop equipment, mechanical systems, and lightning protection systems. The drawings are designated as 90% design review set documents dated August 19, 2026, prepared by Testing Engineers & Consultants of Troy, Michigan.
The specifications identify three acceptable EPDM membrane manufacturers: Carlisle, Johns Manville, and Elevate (Firestone). Contractors are required to provide an alternate price for a 20-year total system warranty on the roof system. The contract documents mandate that contractors verify existing site conditions prior to proposal submission, including building dimensions, roof area dimensions, drainage component locations, and existing roof system composition. Contractors must assume responsibility for final insulation system layout and provide a tapered insulation layout plan supplied by the insulation manufacturer. The project requires adherence to all applicable federal, state, and local building codes and regulations, with immediate notification to the owner of any conflicts between specified products and code requirements. Specific provisions address asbestos-containing material (ACM) abatement procedures, temporary displacement and reinstallation of rooftop equipment, raising of roof curbs to achieve minimum 8-inch flashing heights, and recertification of lightning protection systems following completion of work in accordance with NFPA 780 and UL 96A standards.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 01 OF 06
TITLE SHEET
PROJECT LOCATION MAP
ROOF PLAN SYMBOL LEGEND:
ORD
INS
C
S SKYLIGHT CURB
CAPPED CURB
ROOF HATCH
ROOF CURB
SUPPORT CURBS
ROOF DRAIN
ROOF DRAIN WITH INSERT
OVERFLOW ROOF DRAIN
THROUGH-WALL SCUPPER
OVERFLOW ROOF SCUPPER
ORS
SANITARY VENT
TUBULAR PENETRATION
HOT STACK
PIPE CHASE BOX
PERIMETER OR CURBED EDGE
PARAPET WALL OR AREA DIVIDER
EXPANSION JOINT
GUTTER EDGE
PITCH PAN
ROOF-TO-WALL TRANSITION
AREA TRANSITION
SATELLITE DISH ON ROOF
WALKPADW
WALKWAY
SUPPLY OR CONDENSATE LINE
LADDER
SLOPE DIRECTION
RIDGE LINE
DUCT WORK
R RAISED EQUIPMENT
DOWNSPOUT SPLASHBLOCKS
SUMP AREA
DOWNSPOUTCHIMNEY
THROUGH-FASCIA SCUPPER
SCUPPER WITH CONDUCTOR BOX DETAIL NUMBER CALLOUT
SHEET NUMBER CALLOUT
SCOPE OF REPLACEMENT MAP
GENERAL NOTES:
1. DRAWINGS ARE PRODUCED AT ARCH D (24-INCH BY 36-INCH) SIZE.
PLEASE NOTE AND VERIFY THE SCALE INDICATED ON EACH DRAWING.
NOTE THAT ROOF PLANS AND OTHER PROJECT DRAWINGS PRODUCED
ON OTHER PAPER SIZES MAY NOT BE CORRECTLY SCALED.
2. ALL COMPONENTS SHOWN ON PROJECT DRAWINGS ARE NEW UNLESS
SPECIFICALLY INDICATED AS EXISTING.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING
PROJECT SITE CONDITIONS. THESE CONDITIONS INCLUDE, BUT ARE NOT
LIMITED TO: BUILDING DIMENSIONS AND PROPOSED PROJECT STAGING
LOCATIONS, ROOF REPLACEMENT AREA DIMENSIONS, ROOF DRAINAGE
COMPONENT LOCATIONS, ROOF PENETRATION LOCATIONS, EXISTING
ROOF SYSTEM COMPONENT MAKE-UP AND THICKNESS, AND PROJECT
REPAIR QUANTITIES (IF APPLICABLE). THE CONTRACTOR SHALL VISIT
AND BECOME FAMILIAR WITH THE SITE AND BUILDING PRIOR TO
PROPOSAL SUBMISSION. INCLUDE THE COST OF ALL WORK DESCRIBED
IN THE BIDDING DOCUMENTS AND THAT IS REQUIRED OR REASONABLY
IMPLIED TO ACHIEVE THE DESIGN INTENT OF THE BIDDING DOCUMENTS.
NOTIFY THE ROOF CONSULTANT OF ANY CONFLICTS BETWEEN EXISTING
CONDITIONS AND THE NEW WORK, OF ANY OMISSIONS OR CONFLICTS IN
THE DRAWINGS AND ANY RESTRICTIONS RELATED TO THE EXECUTION
OF THE WORK INCLUDING THE COORDINATION WITH OTHER TRADES.
4. PRODUCTS PROPOSED FOR USE AND PROJECT WORK SHALL BE IN
ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL
GOVERNING ORDINANCES, CODES AND REGULATIONS. NOTIFY THE
OWNER IMMEDIATELY OF CONFLICTS BETWEEN THE SPECIFIED
PRODUCTS AND/OR PROJECT WORK REQUIREMENTS AND CODES,
ORDINANCES AND/OR REGULATIONS.
5. IF DISCREPANCIES ARE DISCOVERED WITHIN THE PROJECT MANUAL OR
DRAWINGS; THE OWNER, NOT THE CONTRACTOR, SHALL DETERMINE
THE INTENT OF THE DESIGN AND PROVIDE CLARIFICATION. NO
ALLOWANCE SHALL BE MADE FOR CONTRACTOR MISINTERPRETATION
OR IMPLIED MISINTERPRETATION OF THE PROJECT MANUAL AND
DRAWINGS.
6. REFER TO THE PROJECT MANUAL AND ROOFING SYSTEM
MANUFACTURER WRITTEN INSTRUCTIONS FOR FURTHER CLARIFICATION
OF PROJECT REQUIREMENTS. NOTIFY THE OWNER IMMEDIATELY OF
CONFLICTS BETWEEN THE SPECIFIED DESIGN REQUIREMENTS AND THE
WRITTEN REQUIREMENTS AND RECOMMENDATIONS OF THE ROOFING
SYSTEM MANUFACTURER.
7. CLOSE AND SEAL ABANDONED OPENINGS TO MATCH EXISTING
ADJACENT SURFACES WHERE MECHANICAL, PLUMBING, AND/OR
ELECTRICAL ITEMS ARE REMOVED.
8. CONTRACTOR SHALL TAKE NORMAL PRECAUTIONS SO THAT DEBRIS,
ROOFING MATERIAL, ETC., DOES NOT FALL INTO THE BUILDING OR ON
EQUIPMENT PER SECTIONS 014000 AND 015000.
SUMMARY OF ROOF REPLACEMENT WORK - AREAS A-W
A. ASBESTOS LABORATORY ANALYSIS REPORT: REFER TO SECTION 022623 FOR INFORMATION
RELATING TO THE LOCATION OF ACM, IF APPLICABLE, WITHIN PROJECT AREAS. IF POSITIVE, REFER TO SECTIONS 013543 AND 028233 FOR PROCEDURES AND REQUIREMENTS RELATED TO
THE REMOVAL AND DISPOSAL OF NON-FRIABLE ASBESTOS RELATED TO THIS PROJECT.
B. ROOF REMOVAL AND SUBSTRATE PREPARATION: REMOVE EXISTING ROOF SYSTEM DOWN TO
THE STRUCTURAL DECK, INCLUDING ROOF MEMBRANE(S), AND UNDERLYING INSULATION,
UNDERLAYMENTS, AND ADDITIONAL ROOF MEMBRANES. INSPECT THE EXISTING STRUCTURAL
DECK, AND INFORM THE OWNER IMMEDIATELY OF OBSERVED DAMAGE AND OR
DETERIORATION. TEMPORARILY DISPLACE ROOFTOP EQUIPMENT AS NECESSARY TO
COMPLETE THE SPECIFIED WORK. REFER TO SECTION 024100.
C. AFTER ROOF REMOVAL AND INSPECTION OF THE EXISTING STRUCTURAL DECK AND PERIMETER
WOOD BLOCKING, PERFORM REPAIRS TO THE STRUCTURAL DECK, AS DETERMINED
NECESSARY BY THE OWNER. REFER TO SECTION 053123. REPLACE DAMAGED OR
DETERIORATED WOOD BLOCKING, AS DETERMINED NECESSARY BY THE OWNER. REFER TO
SECTION 061053.
D. PROVIDE REQUIRED WOOD BLOCKING WHERE INDICATED ON THE PROJECT DRAWINGS. REFER
TO SECTION 061053.
E. PROVIDE A TAPERED POLYISOCYANURATE INSULATION SYSTEM WITH AN INSULATION SYSTEM SLOPE OF 1/8-INCH PER FOOT, AND A STARTING THICKNESS OF 1/2-INCH OVER A BASE LAYER
OF 2-1/2 INCH POLYISOCYANURATE INSULATION. IF INDICATED ON THE PROJECT DRAWINGS,
PROVIDE INSULATION SADDLES AND CRICKETS WHERE SHOWN. REFER TO SECTION 072223
FOR ADDITIONAL INSULATION PRODUCT AND INSTALLATION REQUIREMENTS.
F. PROVIDE A 1/2-INCH HIGH DENSITY POLYISO COVER BOARD OVER THE UNDERLYING
INSULATION. REFER TO SECTIONS 072223 FOR ADDITIONAL PRODUCT AND INSTALLATION
REQUIREMENTS.
G. PROVIDE A FULLY-ADHERED, NOMINAL 60-MIL EPDM ROOF SYSTEM. AFTER INSTALLATION OF
SPECIFIED INSULATION AND COVER BOARD, INSTALL THE EPDM ROOFING MEMBRANE IN
BONDING ADHESIVE. PROVIDE EPDM AND SHEET METAL FLASHINGS AS SPECIFIED. PROVIDE
AN ALTERNATE PRICE FOR A 20-YEAR, “TOTAL SYSTEM WARRANTY” FOR THE ROOF SYSTEM.
REFER TO SECTIONS 075323 AND 076205 FOR PRODUCT AND INSTALLATION REQUIREMENTS.
1. ACCEPTABLE MANUFACTURERS:
a. CARLISLE
b. JOHNS MANVILLE
c. ELEVATE (FIRESTONE)
H. PROVIDE SEALANTS AT LOCATIONS INDICATED ON THE PROJECT DRAWINGS. REFER TO
SECTION 079201.
INDEX OF DRAWINGS:
SHEET 01 OF 05
SHEET 02 OF 05
SHEET 03 OF 05
SHEET 04 OF 05
SHEET 05 OF 05
SHEET 06 OF 05
TITLE SHEET
GENERAL INFORMATION SHEET 01 OF 01
ROOF PLAN - AREAS A-J, V & W
ROOF PLAN - AREAS K-U
ROOF PLAN DETAILS 01-09
ROOF PLAN DETAILS 10-18
XX
X
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
90% Design Review Set
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
08/19/2026
Cass Technical High School
2501 2nd Street Detroit, MI 48201
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 02 OF 06
GENERAL
INFORMATION
SHEET 01 OF 01
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
EXISTING CONDITIONS:
NOTE: THE INFORMATION BELOW IS BASED ON RANDOM, LIMITED TEST CORES
MADE INTO THE ROOFING SYSTEM. CONDITIONS AT THE TEST CORE
LOCATIONS MAY NOT BE REPRESENTATIVE OF THE ENTIRE ROOF AREA.
IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY
EXISTING ROOF SYSTEM COMPONENTS AND SLOPE.
ROOF AREAS A-S
· GRANULE SURFACE MOD-BIT WITH COATING
· 3/4-INCH WOOD FIBER
· TAPERED POLYISO
· 2-1/2 INCH POLYISO
· STEEL DECK - NO SLOPE IN DECK
PROPOSED ROOF SYSTEMS:
NOTE: REFER TO SECTION 011000 - SUMMARY OF WORK, AND RELATED PROJECT
MANUAL SECTIONS FOR ADDITIONAL PRODUCT AND INSTALLATION
REQUIREMENTS FOR THE PROJECT.
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
RECOMMENDED MAXIMUM L:W RATIOS FOR SADDLES AND CRICKETS
ROOF SLOPE SADDLE MATERIAL
SLOPE L:W RATIO
1/8 1/4 2:1
1/4 1/2 3:1
1/2 1 4:1
L
W
CRICKET DRAIN SUMP AREA
SADDLE
ROOF CURB
CRICKETS MUST BE USED ON THE UPHILL SLOPE OF
ANY CURB THAT IS GREATER THAN 24-INCHES
L
W
COVER BOARD & INSULATION ATTACHMENT REQUIREMENTS:
PROPOSED ROOF SYSTEM - ROOF AREAS A-W (APPROX. 103,914 SF.):
· FULLY-ADHERED 60-MIL EPDM WITH 6-INCH SEAMS
· 1/2-INCH HIGH DENSITY POLYISO COVERBOARD - ADHERED AS SPECIFIED
· 1/8-INCH PER FOOT TAPERED POLYISOCYANURATE INSULATION WITH A
1/2-INCH STARTIGN THICKNESS - ADHERED AS SPECIFIED
· 2-1/2 INCH POLYISOCYANURATE INSULATION - ADHERED AS SPECIFIED
· EXISTING CONCRETE DECK - NO SLOPE IN DECK
90% Design Review Set
PROJECT SPECIFIC KEY NOTES:
PROVIDE TAPERED DRAINAGE SUMPS AT ROOF DRAIN LOCATIONS INDICATED ON THE ROOF PLAN.
REFER TO DETAILS 04, 05, 06 AND SECTION 072223 FOR PRODUCT AND INSTALLATION REQUIREMENTS.
CONTRACTOR SHALL PROVIDE CONCRETE SPLASH BLOCK AT THE BASE OF DOWNSPOUT - SET
CONCRETE SPLASH BLOCK ON WALKPAD APPROVED BY THE ROOFING MEMBRANE MANUFACTURER.
INSTALL NEW INSULATION SADDLES BETWEEN ROOF DRAINS AND AT OTHER LOCATION INDICATED ON ROOF PLAN - REFER TO SECTION 072223 FOR PRODUCT AND INSTALLATION REQUIREMENTS - ADJUST
SADDLE CONFIGURATION BASED ON FIELD CONDITIONS OBSERVED.
CONTRACTOR SHALL SEAL TOP EDGE OF MEMBRANE AND TERM BAR WITH MANUFACTURERS LIQUID APPLIED FLASHING SYSTEM WHERE 8-INCH FLASHING CANNOT BE ACHIEVED - REFER TO SECTION
075323 FOR PRODUCT REQUIREMENTS.
EXISTING LIGHTNING PROTECTION SYSTEM - TEMPORARILY DISPLACE TO ALLOW FOR INSTALLATION
OF THE ROOF SYSTEM. AFTER COMPLETION OF WORK THE SYSTEM SHALL BE RECERTIFIED TO
ENSURE COMPLIANCE WITH LIGHTNING PROTECTION REQUIREMENTS.] THE COMPLETED
REINSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL FIRE PROTECTION
ASSOCIATION'S (NFPA) "STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION SYSTEMS - [LATEST EDITION], AND THE "INSTALLATION REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS, UL 96A" OF UNDERWRITERS LABORATORIES INC. THE LIGHTNING RISK ASSESSMENT CONTAINED IN APPENDIX L OF THE NFPA 780-2004 SHALL BE PERFORMED. COORDINATE DETAILS OF ATTACHMENT OF
ROOF MOUNTED LIGHTNING ARRESTERS AND CONDUCTORS WITH ROOF MEMBRANE SYSTEM
MAUFACTURER. REFER TO SECTION 0264113 FOR PRODUCT AND INSTALLATION REQUIREMENTS.
CONTRACTOR TO RAISE CURBS AS NEEDED TO ACHIEVE A MINIMUM FLASHING HEIGHT OF 8-INCHES - RAISE ALL ELECTRICAL, PLUMBING AND MECHANICAL AS NEEDED - ALL WORK IS TO BE PERFORMED
BY LICENSED PROFESSIONAL TO PERFORM SUCH WORK.
EXISTING GAS, CONDUIT AND CONDENSATE LINES ON ROOF - TEMPORARILY DISPLACE TO ALLOW FOR
INSTALLATION OF NEW ROOF SYSTEM. PROVIDE NEW CONNECTIONS WHERE EXISTING IS
DETERIORATED - ADD NEW WHERE MISSING OR AS NEEDED FOR PROPER COMPLETE
REINSTALLATION. RE-INSTALL ON NEW PREFABRICATED SUPPORTS AND SET ON NEW WALKPADS.
ROUTE CONDENSATE LINES TO NEAREST ROOF DRAIN. NOTE THAT DISCONNECTION AND
RECONNECTION OF GAS AND CONDUIT LINES SHALL BE PERFORMED BY A CONTRACTOR LICENSED TO
PERFORM THE SPECIFIED WORK.
EXISTING OVERFLOW DRAINS - CONTRACTOR SHALL ADJUST HEIGHT OF DRAIN TO ACCOMMODATE
NEW ROOF SYSTEM THICKNESS.
A
B
C
ROOF AREAS T & U
· GRANULE SURFACE MOD-BIT
· 3/4-INCH WOOD FIBER
· TAPERED POLYISO
· 2-1/2 INCH POLYISO
· STEEL DECK - NO SLOPE IN DECK
FIELD OF ROOF PERIMETERS CORNERS
COVER BOARD
TOP AND INTERMEDIATE
INSULATION LAYER(S)
BOTTOM INSULATION
LAYER
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
12" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
6" O.C.
MECH. ATTACH WITH 12
FASTENERS PER 4' X 8'
BOARD (ONE FASTENER
PER 2.67 SF).
MECH. ATTACH WITH 24
FASTENERS PER 4' X 8'
BOARD (ONE FASTENER
PER 1.33 SF).
LOOSE-LAID
LOOSE-LAID
MECH. ATTACH WITH 32
FASTENERS PER 4' X 8'
BOARD (ONE FASTENER
PER 1.00 SF).
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
12" O.C.
ADHERED IN TWO-PART
URETHANE FOAM
ADHESIVE 3/4" BEADS
6" O.C.
ATTACHMENT FOR
STEEL DECKS
08/19/2026
Cass Technical High School
2501 2nd Street Detroit, MI 48201
D
E
F
G
H
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
R
272' 31' 31' 61'
15'
29'
212'
60'
30'
45'
14'
17'
15'
40'
360'
135'
211'
13'
40'
20'
15'
30'-6"
110' 61'
62'
20' 34'
60'
30'
27'
ORD
ORD
ROOF PLAN - AREAS A-J, V & W
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 03 OF 06
ROOF PLAN
AREAS A-J, V & W
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
90% Design Review Set
NOTE: TAPERED INSULATION LAYOUT
THE ROOFING CONTRACTOR IS RESPONSIBLE FOR THE FINAL INSULATION
SYSTEM LAYOUT. THE ROOFING CONTRACTOR SHALL PROVIDE A TAPERED
INSULATION LAYOUT PLAN, PROVIDED BY THE INSULATION MANUFACTURER,
PER SECTION 013300.
27'
05 TYP.
05 TYP.
05 TYP.
05 TYP.
05 TYP.
06 10
05 TYP.
05 TYP.
06 13
05 TYP.
05 TYP.
06TYP. 4
SIDES
05 TYP.
05 TYP.
05 TYP.05
05 TYP. 06
05TYP.
05 TYP.
05 TYP.
ROOF AREA A
11,007 SF.
ROOF AREA B
1,800 SF.
ROOF AREA D
915 SF.
ROOF AREA E
465 SF.
ROOF AREA F
465 SF.
ROOF AREA C
11,216 SF.
ROOF AREA W
1,240 SF.
ROOF AREA V
2,040 SF.
ROOF AREA G
435 SF.
ROOF AREA I
8,649 SF.
ROOF AREA H
2,399 SF.
ROOF AREA J
1,620 SF.
ROOF AREA C1
471 SF.
ROOF AREA X
NOT IN CONTRACT
08/19/2026
Cass Technical High School
2501 2nd Street Detroit, MI 48201
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT KEY PLAN
REPLACEMENT
AREAS
A TYP.A TYP.
A TYP.
A TYP.
A TYP.
BTYP.
C TYP.
C TYP.
C TYP.
C TYP.
CTYP.
CTYP.
F TYP.
F TYP.
F TYP.
D E
D E D E
D E
D E
D E
D ED E
H
H
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text 16'
AutoCAD SHX Text 32'
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"
AutoCAD SHX Text 8'
AutoCAD SHX Text 8'
AutoCAD SHX Text
NORTH
RRRR
ROOF PLAN - AREAS K-U
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 04 OF 06
ROOF PLAN
AREAS K-U
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
90% Design Review Set
NOTE: TAPERED INSULATION LAYOUT
THE ROOFING CONTRACTOR IS RESPONSIBLE FOR THE FINAL INSULATION
SYSTEM LAYOUT. THE ROOFING CONTRACTOR SHALL PROVIDE A TAPERED
INSULATION LAYOUT PLAN, PROVIDED BY THE INSULATION MANUFACTURER,
PER SECTION 013300.
111'
99'
135' 55' 14'
181'
152'
71'
12'
25'
29'
42' 17'
12'
105'
36'
44'
31'
15'
75'
115'
05 TYP. 04
05 TYP.05
05 TYP.
05 TYP.
05TYP.
05TYP.
05TYP.
05TYP.
05 TYP.07
05 TYP.
05TYP.
05TYP.
05TYP.05
05TYP.
05TYP.
05TYP.
05 TYP.
05TYP.
06 12
06 12
TYP. 4
SIDES
TYP. 4
SIDES
05TYP.04
05TYP.
05TYP.
05TYP.
05TYP. 07
05TYP.
05TYP.
63'
19'
63'
19'
ROOF AREA L1
10,989 SF.
ROOF AREA Y
NOT IN CONTRACT
ROOF AREA M
3,996 SF.
ROOF AREA N
4,758 SF.
ROOF AREA W
1,240 SF.
ROOF AREA L
21,462 SF.
ROOF AREA K
10,125 SF.
ROOF AREA O
182 SF.
ROOF AREA P
370 SF.
ROOF AREA T
1,185 SF.
ROOF AREA U
1,197 SF.
ROOF AREA S
2,534 SF.
ROOF AREA R
937 SF.
08/19/2026
Cass Technical High School
2501 2nd Street Detroit, MI 48201
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT
SKYLIG
HT KEY PLAN
REPLACEMENT
AREAS
D E
D E
D E
D E
D E
D E
D E
A TYP.
A TYP.
C TYP.
A TYP.
A TYP.
A TYP.
A TYP.
A TYP.
C TYP.
C TYP.
C TYP.
C TYP.
C TYP.C TYP.
SOLAR ARAY
F TYP.
F TYP.
F TYP.
G TYP.
G TYP.
AutoCAD SHX Text
NORTH
AutoCAD SHX Text
AutoCAD SHX Text 16'
AutoCAD SHX Text 32'
AutoCAD SHX Text
SCALE: 1/16" = 1'-0"
AutoCAD SHX Text 8'
AutoCAD SHX Text 8'
NORTH
WOOD BLOCKING - IF NECESSARY TO ACHIEVE
8-INCH MINIMUM FLASHING HEIGHT. SECURE TO
SUBSTRATE 18-INCHES O.C. AND WITHIN 2-INCHES
OF EACH END.
EXISTING ROOFTOP UNIT - TEMPORARILY DISPLACE
TO ALLOW FOR INSTALLATION OF NEW ROOF
SYSTEM AND RELATED FLASHING COMPONENTS.
REINSTALL TO ORIGINAL POSITION AFTER
COMPLETION OF WORK. RE-SECURE TO EXISTING
CURB WITH GASKETED FASTENERS 12-INCHES O.C.
MAX., AND WITHIN 2-INCHES OF EACH CORNER.
CURB INSULATION - IF EXISTING
CURB IS INSULATED, AND
EXISTING INSULATION CANNOT BE
SALVAGED, PROVIDE CURB
INSULATION TO MATCH EXISTING.
PREFINISHED 24 GA. GALV. STEEL
SURFACE-MOUNTED
COUNTERFLASHING. SECURE TO
EXISTING CURB COUNTERFLASHING
AS SHOWN USING GASKETED
FASTENERS 12-INCHES O.C. MAX.,
AND WITHIN 2-INCHES OF EACH END.
SELF-ADHERING MEMBRANE
COMPATIBLE WITH EXISTING
SUBSTRATE(S)
REFER TO DETAILS BELOW FOR
FLASHING REQUIREMENTS.
ALT. COUNTERFLASHING NO. 2
FOR USE WHERE APPROVED AND WHERE
EXISTING CURB IS SEPARATED FROM THE
EXISTING ROOFTOP PENETRATION
BUTYL TAPE - INSTALL BEHIND
COUNTERFLASHING
SEALANT
NOTE: SECURE TOP EDGE OF FLASHING USING AN
ALUMINUM TERMINATION BAR SECURED
12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO
TERMINATION BAR INSTALLATION, INSTALL
MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL
TOP EDGE OF FLASHING AND TERMINATION
BAR AFTER INSTALLATION.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING
CORNERS FOLLOWING THE
RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE
MANUFACTURER. PROVIDE "T-JOINT
COVERS" AT THE BASE OF THE CURB AT
FLASHING PIECE INTERSECTIONS.
ALT. VERTICAL MEMBRANE TERMINATION
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
4" M
IN
4" M
IN
8" M
IN
FL
AS
H
IN
G H
EI
G
H T
NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS
OF ELECTRICAL, PLUMBING OR
MECHANICAL CONNECTIONS RELATED TO
THE DISPLACEMENT AND RE-INSTALLATION
OF ROOFTOP UNITS SHALL BE PERFORMED
BY A CONTRACTOR LICENSED TO PERFORM
SUCH WORK. COORDINATE THIS WORK
WITH THE OWNER.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT
SHOWN FOR CLARITY.
SPECIFIED POLYISO. INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 6-INCHES O.C. MAX.
EPDM MEMBRANE, 8" MIN. HEIGHT, FULLY
ADHERED TO CURB. REFER TO NOTE
REGARDING SECUREMENT OF MEMBRANE.
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
BATTEN STRIP OR FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
1-1/4" 1/2"
APPR
O
X.
2-3/4"
EPDM MEMBRANE, FULLY ADHERED TO CURB. 8" MIN.
HEIGHT, REFER TO NOTE REGARDING SECUREMENT
OF FLASHING.
APPROX.
1/2"
ALT. VERTICAL TERMINATION -
TWO PIECE FLASHING
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
APPROX.
1/2"
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER TO
UNDERLYING EPDM ROOF MEMBRANE AND OVERLYING
EPDM FLASHING MEMBRANE PRIOR TO APPLICATION.
1-1/4" 1/2"
APPR
O
X.
2"
PRESSURE-SENSITIVE OUTERSEAM FLASHING;
MINIMUM 5-INCH WIDTH. SEAL EDGES AS SHOWN.
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER
TO UNDERLYING EPDM ROOF MEMBRANE
AND OVERLYING EPDM FLASHING
MEMBRANE PRIOR TO APPLICATION.
BATTEN STRIP OR FASTENERS AND 2-INCH
PLATES, 12-INCHES O.C. MAX.
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; MIN. 5-INCH WIDTH. SEAL
EDGES AS SHOWN.
4" M
IN
WRAP EPDM MEMBRANE FLASHING OVER
THE TOP OF THE CURB AND SECURE TO
THE INSIDE OF THE CURB WITH 1" METAL
CAP NAILS AT 6" O.C. MAXIMUM.
MEMBRANE SECUREMENT
ALT. TWO-PIECE FLASHING
PREFINISHED 24 GA. GALV.
STEEL SLIP COUNTERFLASHING.
SECURE TO EXISTING CURB
COUNTERFLASHING AS SHOWN
USING GASKETED FASTENERS
12-INCHES O.C. MAX., AND
WITHIN 2-INCHES OF EACH END.
EXISTING ROOFTOP UNIT
COUNTERFLASIHNG
REFER TO DETAILS BELOW FOR
FLASHING REQUIREMENTS.
ALT. COUNTERFLASHING NO. 1
FOR USE WHERE APPROVED AND WHERE EXISTING
ROOFTOP UNIT CANNOT BE DISPLACED TO ALLOW FOR
FLASHING, OR WHERE GAP BETWEEN EXISTING
ROOFTOP UNIT COUNTERFLASHING AND CURB IS TOO
NARROW TO ACCOMMODATE FLASHING
4" M
IN
8" M
IN
FL
AS
H
IN
G H
EI
G
H T
EXIST. ROOFTOP PENETRATION
EPDM FLASHING, 8" MIN. HEIGHT, FULLY
ADHERED TO CURB. REFER TO NOTE
REGARDING SECUREMENT OF MEMBRANE.
ALT. NOTE:
ALT. SECUREMENT
2-3/4"
8" M
IN
IM
U M
H
EI
G H
T
NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF ELECTRICAL,
PLUMBING OR MECHANICAL COMPONENTS RELATED TO
THE DISPLACEMENT AND RE-INSTALLATION OF ROOFTOP
UNITS SHALL BE PERFORMED BY A CONTRACTOR LICENSED
TO PERFORM SUCH WORK. COORDINATE THIS WORK WITH
THE OWNER.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
NOTE: APPLY WATER CUT OFF MASTIC TO THE BACKSIDE OF
FLASHING PRIOR TO COUNTERFLASIHNG INSTALLATION.
USE COUNTERFLASHING AS SECUREMENT PIECE FOR
FLASHING AS SHOWN.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
APPROX.
1/2"
EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO
NOTE REGARDING SECUREMENT OF FLASHING.
REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED
SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
EXISTING ROOF HATCH ON CURB -
RAISE TO ACCOMMODATE NEW
ROOF SYSTEM ELEVATION, AND
RE-SECURE FLANGE TO WOOD
BLOCKING AS SHOWN. PROVIDE
INTERIOR FINISH REPAIRS AS
NEEDED TO ACCOMMODATE
RAISING OF CURB.
NOMINAL WOOD BLOCKING.
THICKNESS TO MATCH EXISTING
COVER BOARD AND INSULATION
THICKNESS; WIDTH GREATER
THAN ROOF HATCH CURB AND
CURB FLANGE. SECURE TO
SUBSTRATE 18-INCHES O.C.
WITH SPECIFIED FASTENERS
APPROPRIATE FOR THE
SUBSTRATE ENCOUNTERED.
PREFINISHED 24 GA. GALV.
STEEL SLIP COUNTERFLASHING.
SECURE TO EXISTING CURB
COUNTERFLASHING AS SHOWN
USING GASKETED FASTENERS
12-INCHES O.C. MAX., AND
WITHIN 2-INCHES OF EACH END.
APPLY SEALANT TO BACKSIDE
OF COUNTERFLASHING PRIOR
TO INSTALLATION.
NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF ELECTRICAL,
PLUMBING OR MECHANICAL COMPONENTS RELATED TO
THE DISPLACEMENT AND RE-INSTALLATION OF ROOFTOP
UNITS SHALL BE PERFORMED BY A CONTRACTOR LICENSED
TO PERFORM SUCH WORK. COORDINATE THIS WORK WITH
THE OWNER.
4" M
IN
8" M
IN
IM
U M
H
EI
G H
T
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
NOTE: SECURE TOP EDGE OF FLASHING WITH 1-INCH BY 1/8-INCH
ALUMINUM ANCHOR BAR SECURED 12-INCHES O.C. MAX.
AND WITHIN 2-INCHES OF EACH END. APPLY WATER CUT
OFF MASTIC TO THE BACKSIDE OF FLASHING PRIOR TO
ANCHOR BAR INSTALLATION. APPLY SEALANT TO TOP
EDGE OF FLASHING AND ANCHOR BAR AFTER COMPLETION
OF WORK. IF SUBSTRATE IS WOOD, NAILS AFFIXED WITH
1-INCH METAL CAPS, 6-INCHES O.C. MAX., MAY BE USED IN
LIEU OF TERMINATION BAR.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO
NOTE REGARDING SECUREMENT OF FLASHING.
REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED
SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
APPROX.
1/2"
APPROX.
1/2"
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER
TO UNDERLYING EPDM ROOF MEMBRANE
AND OVERLYING EPDM FLASHING
MEMBRANE PRIOR TO APPLICATION.
2"
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; MINIMUM 5-INCH WIDTH.
SEAL EDGES AS SHOWN.
ALT. TWO-PIECE FLASHING
EPDM FLASHING, 8" MIN. HEIGHT,
FULLY ADHERED TO CURB. REFER
TO NOTE REGARDING SECUREMENT
OF MEMBRANE.
ALT. VERTICAL MEMBRANE TERMINATION
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
BATTEN STRIP OR FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
1-1/4" 1/2"
APPR
O
X.
2-3/4"
EPDM MEMBRANE, FULLY ADHERED TO CURB. 8" MIN.
HEIGHT, REFER TO NOTE REGARDING SECUREMENT
OF FLASHING.
ALT. VERTICAL TERMINATION -
TWO PIECE FLASHING
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
1-1/4" 1/2"
APPR
O
X.
2-3/4"
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER TO
UNDERLYING EPDM ROOF MEMBRANE AND
OVERLYING EPDM FLASHING MEMBRANE PRIOR
TO APPLICATION.
BATTEN STRIP OR FASTENERS AND 2-INCH
PLATES, 12-INCHES O.C. MAX.
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; MIN. 5-INCH WIDTH. SEAL
EDGES AS SHOWN.
TWO PIECE- PREFINISHED 24 GA. GALV. STEEL
CURB CAP. SECURE VERTICAL FACE OF CAP
WITH GASKETED FASTENERS, 12-INCHES O.C.
MAX., AND WITHIN 2-INCHES OF EACH END.
EXISTING UNIT ON CURB SUPPORTS.
TEMPORARILY DISPLACE TO ALLOW FOR
INSTALLATION OF NEW ROOF SYSTEM AND
RELATED FLASHING. REINSTALL ON NEW SHEET
METAL CAP AFTER COMPLETION OF WORK.
EXISTING SUPPORT CURB
EXISTING WOOD BLOCKING TO MATCH SUPPORT
CURB LENGTH AND WIDTH
LCC
TAPERED POLYISOCYANURATE INSULATION, AND/OR
TAPERED EDGE STRIP(S) AS NECESSARY TO RESULT IN A
8-FOOT BY 8-FOOT MINIMUM TAPERED ROOF DRAIN SUMP
AREA WITH A MINIMUM SLOPE OF 1/4-INCH PER FOOT.
EXISTING ROOF DRAIN ASSEMBLY. CLEAN BOWL FREE OF ALL
EXISTING FLASHING MATERIALS AND BITUMINOUS RESIDUE PRIOR
TO INSTALLATION OF EPDM ROOFING MEMBRANE AND
MANUFACTURER'S RECOMMENDED SEALANT. INSPECT DRAIN
BOWL, CLAMPING RING, AND OTHER ASSEMBLY COMPONENTS FOR
DAMAGE. REPLACE DAMAGED COMPONENTS AS NECESSARY PER
SECTION 024100.
EXISTING ROOF DRAIN STRAINER. REMOVE AND DISCARD
DAMAGED, BROKEN OR PLASTIC-TYPE STRAINER(S).
REPLACE DISCARDED STRAINERS WITH CAST IRON
STRAINERS. REFER TO SECTION 024100.
PLAN VIEW OF ROOF SUMP AREA
SCALE: NONE
TAPERED INSULATION/EDGE STRIPS AS NEEDED
TO RESULT IN 8'-0" X 8'-0" SUMP AREA
ROOF DRAIN
NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING
RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE
CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN
FLASHING COMPONENTS.
CUT DRAINAGE HOLE IN MEMBRANE MIN. 1/2" GREATER
THAN DRAIN PIPE DIAM. ON ALL SIDES
EXTEND MEMBRANE 1" MIN.
BEYOND CLAMPING RING
MANUFACTURER'S RECOMMENDED SEALANT. INSTALL ONE TUBE,
MINIMUM, UNDER EPDM ROOFING MEMBRANE AT CLAMPING RING,
CONTINUOUS BEAD - TO ROOF DRAIN ASSEMBLY INTERSECTION.
IN
ST
AL
L
TA
PE
R
ED
P O
LY
IS
O C
YA
N
U R
AT
E
IN
SU
LA
TI
O N
A N
D /O
R T
AP
ER
ED
E
D G
E
ST
R
IP
T O
R
ES
U
LT
IN
' x
' S U
M P
AR
EA
(T
YP
APPROX. 4'-0" - REFER TO NOTE ABOVE REGARDING ROOF SUMP AREA
CONSTRUCTION AND SLOPE REQUIREMENTS
IN
ST
AL
L
TA
PE
R
ED
P O
LY
IS
O C
YA
N
U R
AT
E
IN
SU
LA
TI
O N
A N
D /O
R T
AP
ER
ED
E
D G
E
ST
R
IP
T O
R
ES
U
LT
IN
' x
' S U
M P
AR
EA
(T
YP
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
NOTE: IF FIELD SEAM EDGE IS WITHIN 9" OF DRAIN COMPRESSION
RING, EPDM TARGET PATCH REQUIRED.
PLAN VIEW OF ROOF SUMP AREA
SCALE: NONE
ROOF DRAIN
NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING
RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE
CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN
FLASHING COMPONENTS.
IN
ST
AL
L
TA
PE
R
ED
P O
LY
IS
O C
YA
N
U R
AT
E
IN
SU
LA
TI
O N
A N
D /O
R T
AP
ER
ED
E
D G
E
ST
R
IP
T O
R
ES
U
LT
IN
' W
ID
E M
IN
. S
U M
P
AR
EA
(T
YP
. A
LL
S
ID
ES
NOTE: FIELD MEMBRANE SEAMS MUST NOT RUN THRU ROOF SUMP
AREA.
LCC
LCC
EXISTING ROOF DRAIN ASSEMBLY. CLEAN BOWL FREE OF
ALL EXISTING FLASHING MATERIALS AND BITUMINOUS
RESIDUE PRIOR TO INSTALLATION OF EPDM ROOFING
MEMBRANE AND MANUFACTURERS RECOMMENDED
SEALANT. INSPECT DRAIN BOWL, CLAMPING RING, AND
OTHER ASSEMBLY COMPONENTS FOR DAMAGE. REPLACE
DAMAGED COMPONENTS AS NECESSARY PER SECTION
024100.
EXISTING ROOF DRAIN STRAINER. REMOVE AND DISCARD
DAMAGED, BROKEN OR PLASTIC-TYPE STAINER(S).
REPLACE DISCARDED STRAINERS WITH CAST IRON
STRAINERS. REFER TO SECTION 024100.
MANUFACTURERS RECOMMENDED SEALANT. INSTALL ONE
TUBE, MINIMUM, CONTINUOUS BEAD, UNDER EPDM ROOFING
MEMBRANE AT CLAMPING RING - TO ROOF DRAIN ASSEMBLY
INTERSECTION.
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
MIN. 2'-0" - REFER TO NOTE ABOVE REGARDING ROOF SUMP AREA
CONSTRUCTION AND SLOPE REQUIREMENTS
EXISTING OVERFLOW ROOF DRAIN ASSEMBLY. CLEAN
BOWL FREE OF ALL EXISTING FLASHING MATERIALS AND
BITUMINOUS RESIDUE PRIOR TO INSTALLATION OF EPDM
ROOFING MEMBRANE AND MANUFACTURERS
RECOMMENDED SEALANT. INSPECT DRAIN BOWL,
CLAMPING RING, AND OTHER ASSEMBLY COMPONENTS FOR
DAMAGE. REPLACE DAMAGED COMPONENTS AS
NECESSARY PER SECTION 024100.
OVERFLOW ROOF DRAIN
EXISTING DRAIN SUMP PAN
INSTALL TAPERED POLYISOCYANURATE
INSULATION AND/OR TAPERED EDGE STRIP TO
RESULT IN 2' WIDE MIN. SUMP AREA (TYP. ALL SIDES)
EXISTING DRAIN SUMP PAN
LCC
EPDM ROOFING MEMBRANE
FIELD VERIFY SIZE OF
SCUPPER BOX. MINIMUM
SIZE OF SCUPPER BOX SHALL
MATCH EXISTING.
3" M
IN
1" M
IN
FI
EL
D V
ER
IF
Y
SI
ZE
O
F
SC
U
PP
ER
B
O X.
M
IN
IM
U
M S
IZ
E
O F
SC
U
PP
ER
B O
X
SH
AL
L
M
AT
C H
E
XI
ST
IN
G
. NOTE: ADJUST SCUPPER
OPENING ELEVATION AS
NECESSARY TO RESULT IN
A CONDITION THAT IS
FLUSH WITH THE TOP
ELEVATION OF THE
SPECIFIED COVER BOARD
AND INSULATION.
NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK
AREA USING SOLVENTS AND WIRE BRUSH; REMOVING DIRT,
OIL, GREASE, AND OTHER CONTAMINANTS FROM THE
WORK AREA. TIN THE WORK AREA BY APPLYING ACID
(FLUX). PERFORM SOLDERING WORK. AFTER COMPLETION
OF WORK, REMOVE EXCESS ACID (FLUX) FROM THE WORK
AREA.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT
SHOWN FOR CLARITY.
NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL
RECEIVE PRESSURE SENSITIVE OUTER SEAM
FLASHING PRIOR TO APPLICATION.
NOTE: TURN FLASHING INTO SCUPPER SLEEVE MIN.
1-1/2 INCHES ON ALL SIDES.
PLAN VIEW OF TAPERED AREA
AT SCUPPER
TAPERED INSULATION/EDGE
STRIPS AS NEEDED TO RESULT
IN 4'-0" X 8'-0" SUMP AREA WITH
MINIMUM 1/4-INCH PER FOOT
SLOPE
SCUPPER OPENING 8'-0" MINIMUM
FIELD VERIFY
SCUPPER
DIMENSION
WALL OR PERIMETER
EDGE
4' -0
" M
IN
IM
U
M
WOOD BLOCKING (IF NECESSARY) TO MATCH
COVER BOARD AND INSULATION THICKNESS.
SECURE TO SUBSTRATE 18-INCHES O.C. MAX.,
AND WITHIN 2-INCHES OF EACH END.
FIELD
VERIFY
SCUPPER
DIMENSIONS
SEALANT
1" M
IN
ENLARGED REGLET
DETAIL
SCALE: NONE
CUT REGLET INTO WALL
AS SHOWN
SEALANT
PREFINISHED 24 GA. GALV.
STEEL COUNTERFLASHING,
SPRING-LOCKED INTO REGLET
AND SECURED WITH GASKETED
FASTENERS APPROPRIATE FOR
THE SUBSTRATE 12-INCHES O.C.
MAX.
FU
LL W
ID
TH
O F M
ASO
N
R Y
G R
O U
T JO
IN
T
APPR
O
X.
1-1/4"
APPROX. 1"
DEEP
WALL FLASHING AND
CONFIGURATION WILL VARY.
REFER TO APPLICABLE
FLASHING DETAIL FOR
FLASHING REQUIREMENTS.
TIE-IN SCUPPER FLASHING TO
ADJACENT WALL FLASHING AS
NECESSARY.
PRESSURE-SENSITIVE OUTER SEAM
FLASHING - 5-INCH OR 6-INCH WIDTH.
PRESSURE-SENSITIVE OUTER SEAM
FLASHING - 9-INCH WIDTH. SEAL EDGES AS
SHOWN AFTER COMPLETION OF WORK.
22 GA. STAINLESS STEEL SCUPPER LINER. FABRICATE WITH
4-INCH FLANGES ON ALL SIDES. SOLDER ALL LAPS AND
SEAMS WATERTIGHT - REFER TO NOTE REGARDING
SOLDERING PROCEDURES. SECURE FLANGES TO
SUBSTRATE, 4" O.C. MAX FASTENER SPACING. APPLY
CONTINUOUS BEAD OF MFR. RECOMMENDED SEALANT
BETWEEN SCUPPER FLANGE AND EXISTING STRUCTURE.
PREFINISHED 24 GA. GALV. STEEL DOWNSPOUT RECEIVER
PIECE - SECURE AND SEAL TO BOTTOM OF SCUPPER BOX AS
SHOWN.
PREFINISHED 24 GA. GALV. STEEL RECTANGULAR DOWNSPOUT.
FABRICATE AND INSTALL DOWNSPOUTS IN ACCORDANCE WITH
“SMACNA ARCHITECTURAL SHEET METAL MANUAL, 7TH EDITION.
SECURE DOWNSPOUT TO WALL WITH BRACKETS AND
FASTENERS APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED.
TERMINATE BOTTOM OF DOWNSPOUT TO MATCH EXISTING.
PREFINISHED 24 GA. GALV. STEEL CONDUCTOR BOX.
SECURE TO SUBSTRATE AS SHOWN WITH FASTENERS
APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED.
SCUPPER
LINER DETAIL
SCALE: NONE
4" MIN.
SCUPPER LINER
SCUPPER OPENING
4" MIN.
4" MIN.
MANUFACTURER'S
ACCEPTED FASTENERS,
3" O.C. MAX.
4" MIN.
4" MIN. 1/2" MIN. TAPERED POLYISOCYANURATE INSULATION, AND/OR TAPERED EDGE STRIP(S)
AS NECESSARY TO RESULT IN A 4-FOOT BY 8-FOOT MINIMUM TAPERED AREA AT
SCUPPER WITH A MINIMUM SLOPE OF 1/4-INCH PER FOOT.
EPDM ROOFING MEMBRANE
EXISTING STRUCTURAL DECK
SPECIFIED POLYISO.
INSULATION
COVER BOARD - 1/2-INCH
THICK
CL
NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK AREA USING SOLVENTS
AND WIRE BRUSH; REMOVING DIRT, OIL, GREASE, AND OTHER CONTAMINANTS FROM
THE WORK AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX). PERFORM
SOLDERING WORK. AFTER COMPLETION OF WORK, REMOVE EXCESS ACID (FLUX)
FROM THE WORK AREA.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
CL
MIN. 1" AIR
GAP OR MATCH
EXIST. - WHICHEVER
IS GREATER
4" M
IN
8" M
IN
. F
LA
SH
IN
G
H
EI
G H
T
FIELD-FABRICATED
FLASHING
HOT STACK
NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL
RECEIVE PRESSURE SENSITIVE OUTER SEAM
FLASHING PRIOR TO APPLICATION.
3" MIN3" MIN
2 1/2"
NOTE: WHEN OUTSIDE DIAMETER OF THE PIPE
EXCEEDS 18", ADDITIONAL FIELD MEMBRANE
SECUREMENT REQUIRED. REFER TO
MANUFACTURER'S DETAILS.
PRESSURE-SENSITIVE
FLASHING - 12-INCH WIDTH.
PRESSURE-SENSITIVE
FLASHING - 9-INCH WIDTH.
PRESSURE-SENSITIVE
FLASHING - 5 OR 6-INCH
WIDTH.
PRESSURE-SENSITIVE
OUTERSEAM FLASHING;
6-INCH WIDTH. SEAL
EDGES AS SHOWN.
PRE-FABRICATED
BOOT FLASHING
EXISTING TUBULAR
PENETRATION
PIPE EXTENSION (IF NECESSARY) TO
ACHIEVE 8" MIN. FLASHING HEIGHT.
PROVIDE SEALANT AT INTERSECTION
BETWEEN EXISTING TUBULAR
PENETRATION AND EXTENSION.
24 GA. STAINLESS STEEL STORM COLLAR
SOLDER ALL LAPS AND SEAMS WATERTIGHT.
REFER TO NOTE REGARDING SOLDERING.
INSTALL BUTYL TAPE BEHIND COLLAR AS
SHOWN PRIOR TO INSTALLATION OF CLAMP.
SEAL TOP OF HOOD AS SHOWN.
SEALANT - TYP
STAINLESS STEEL CLAMPING
BAND
STAINLESS STEEL CLAMPING BAND.
PRIOR TO INSTALLATION, APPLY
MANUFACTURERS RECOMMENDED
SEALANT BEHIND EPDM FLASHING.
SEAL TOP OF FLASHING AND BAND
AFTER INSTALLATION.
EXISTING HIGH-TEMPERATURE
TUBULAR PENETRATION
PRESSURE-SENSITIVE FLASHING - 12-INCH
WIDTH.
PRESSURE-SENSITIVE FLASHING - 9-INCH
WIDTH.
PRESSURE-SENSITIVE FLASHING - 5 OR
6-INCH WIDTH.
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; 6-INCH WIDTH. SEAL EDGES
AS SHOWN.
SEALANT - TYP
STAINLESS STEEL
CLAMPING BAND
SPECIFIED POLYISOCYANURATE INSULATION - TYP.
EXISTING STRUCTURAL DECK - TYP.
COVER BOARD - 1/2-INCH THICK - TYP.
EPDM ROOFING MEMBRANE - TYP.
24 GA. STAINLESS STEEL STORM COLLAR
SOLDER ALL LAPS AND SEAMS
WATERTIGHT. REFER TO NOTE
REGARDING SOLDERING. INSTALL BUTYL
TAPE BEHIND COLLAR AS SHOWN PRIOR
TO INSTALLATION OF CLAMP. SEAL TOP
OF HOOD AS SHOWN.
24 GA. STAINLESS STEEL FLANGED
SLEEVE. SOLDER ALL LAPS AND
SEAMS WATERTIGHT. REFER TO
NOTE REGARDING SOLDERING.
SECURE TO STRUCTURAL DECK AS
SHOWN.
NOTE: EXISTING FLANGED SLEEVE
COMPONENTS DETERMINED TO BE
IN GOOD CONDITION AND FREE OF
BITUMINOUS CONTAMINATION MAY
BE CONSIDERED FOR RE-USE.
POURABLE SEALER - SLOPE TO ALLOW FOR PROPER DRAINAGE.
NON-SHRINK GROUT - FILL TO 2" BELOW RIM OF PITCH PAN.
EXISTING IRREGULAR PENETRATION - SIZE AND SHAPE VARIES.
NOTE: DO NOT USE PITCH PANS AT TUBULAR PENETRATIONS
WITHOUT PRIOR OWNER APPROVAL.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
4" M
IN
NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK
AREA USING SOLVENTS AND WIRE BRUSH; REMOVING DIRT,
OIL, GREASE, AND OTHER CONTAMINANTS FROM THE WORK
AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX).
PERFORM SOLDERING WORK. AFTER COMPLETION OF
WORK, REMOVE EXCESS ACID (FLUX) FROM THE WORK
AREA.
AT LOCATIONS WHERE POSSIBLE, PROVIDE A 24 GA. STAINLESS
STEEL JUNCTION/FLASHING BOX. FABRICATE BOX WITH A SLOPED
TOP TO SHED WATER. SOLDER ALL LAPS AND SEAMS WATERTIGHT.
SEAL PENETRATION EXIT OPENINGS WATERTIGHT.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
PRESSURE-SENSITIVE FLASHING - WIDTH AS NECESSARY TO RESULT
IN CONDITION SHOWN.
PRESSURE-SENSITIVE OUTERSEAM FLASHING; WIDTH AS NECESSARY TO
RESULT IN CONDITION SHOWN. SEAL EDGES AS SHOWN.
NOMINAL 6-INCH WOOD BLOCKING AS NECESSARY TO MATCH COVER
BOARD AND INSULATION THICKNESS. SECURE TO SUBSTRATE
18-INCHES O.C. MAX., AND WITHIN 2-INCHES OF EACH END.
4" MIN.
24 GA. STAINLESS STEEL PITCH PAN WITH 6-INCH FLANGE AND ROUNDED
CORNERS. SOLDER ALL SEAMS AND LAPS WATERTIGHT - REFER TO NOTE
REGARDING SOLDERING.
2" MIN. ALL SIDES
NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL
RECEIVE PRESSURE SENSITIVE OUTER SEAM
FLASHING PRIOR TO APPLICATION..
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER
TO NOTE ABOVE REGARDING SECUREMENT OF FLASHING.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
PLAN VIEW OF THROUGH ROOF PIPE CURB
SCALE: NONE
4" M
IN
8" M
IN
NOMINAL WOOD BLOCKING - THICKNESS AS NECESSARY TO
MATCH MAXIMUM ROOF AREA INSULATION AND COVER
BOARD THICKNESS WITH A CONSISTENT FINAL NAILER
ELEVATION.
COMPRESSIBLE/BATT INSULATION AS SPECIFIED
REMOVABLE SHEET METAL COUNTERFLASHING
FLEXIBLE INSULATION RETAINER ATTACHED TO TOP OF CURB
SHEET METAL FLASHING RECIEVER
SLOPE PIPES DOWN AND AWAY FROM HOOD
SHEET METAL OR FLEX-TUBE COLLAR
SEALANT AS SPECIFIED
SHEET METAL ENCLOSURE- CROSS BREAK OR SLOPE FOR
DRAINAGE
REINFORCED PERIMETER FASTENING STRIP
WITH FACTORY-LAMINATED SEAM TAPE.
PRIME MEMBRANE PRIOR TO APPLICATION
TO REINFORCED FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES
O.C. MAX.
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTIONDATE
ISSUE
Drawn By: PD
Checked By: SH
SHEET TITLE
File Name:
STAMP
SHEET 05 OF 06
ROOF PLAN
DETAILS 01-09
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
DETAIL 01 -
SCALE: NONE
ROOF CURB FLASHING DETAIL 02 -
SCALE: NONE
ROOF HATCH CURB FLASHING DETAIL 03 -
SCALE: NONE
SUPPORT CURB FLASHING
DETAIL 04 -
SCALE: NONE
DETAIL 05 -
SCALE: NONE
DETAIL 06 -
SCALE: NONE
THROUGH-WALL SCUPPER FLASHING
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
ROOF DRAIN FLASHING ROOF DRAIN FLASHING
90% Design Review Set08/19/2026
Cass Technical High School
2501 2nd Street Detroit, MI 48201
DETAIL 07 -
SCALE: NONE
DETAIL 08 -
SCALE: NONE
DETAIL 09 -
SCALE: NONE
PIPE CHASE FLASHING PITCH PAN LASHING TUBULAR PENETRATION FLASHING
AutoCAD SHX Text Copyright 1997,1998,1999 United States Postal Service
AutoCAD SHX Text Copyright 1997,1998,1999 United States Postal Service
Copyright 1997,1998,1999 United States Postal Service
2" M
IN
. O
R T
O M
AT
C
H
EX
IS
TI
N G
E
LE
VA
TI
O N
W H
IC
H
EV
ER
IS
G
R
EA
TE
R
3/4"
5/8"
7- 1/
2" M
AX
. F
AC
E
APPROX.
1/2"
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE
REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM
ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
NOTE: SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO TERMINATION BAR
INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE
PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR
AFTER INSTALLATION.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
22 GA. GALV. STEEL CONTINUOUS CLEAT.
FABRICATE WITH A 2-INCH FLANGE. SECURE
FLANGE AND VERTICAL FACE WITH RING SHANK
COATED NAILS 12-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 6-INCHES O.C. WITHIN
10-FEET OF A BUILDING CORNER.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - MIN. 1/2-INCH THICK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP
WITH FACTORY-LAMINATED SEAM TAPE.
PRIME MEMBRANE PRIOR TO APPLICATION
TO REINFORCED FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES
O.C. MAX.
EPDM FLASHING MEMBRANE, FULLY-ADHERED
TO WALL REFER TO NOTE REGARDING
SECUREMENT OF FLASHING.
PREFINISHED 24 GA. GALV. STEEL PERIMETER
EDGE FASCIA PIECE. FABRICATE WITH 1/2-INCH
HUG AT EDGE OF FLANGE AS SHOWN. SECURE
FLANGE WITH NAILS 3-INCHES O.C. MAX. IN TWO
STAGGERED ROWS. HOOK BOTTOM EDGE TO
CONTINUOUS CLEAT.
3/4-INCH PLYWOOD MECHANICALLY
ATTACHED TO EXISTING WALL WITH
PROPER SUBSTRATE FASTENERS - TWO
ROWS 24-INCHES O.C., STAGGERED
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES
AS SHOWN AFTER COMPLETION OF WORK.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.
NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT
PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE
MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND
RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.
TAPERED POLYISOCYANURATE INSULATION. CUT TO MATCH
CONDITION SHOWN.
CREATE A 3-FOOT ENHANCED DRAINAGE AREA WITH A MINIMUM
FINISH SLOPE OF 1/2-INCH PER FOOT AT GUTTER EDGES. CONSTRUCT
THE AREA USING TAPERED POLYISOCYANURATE INSULATION CUT TO
CREATE A FLUSH CONDITION AT THE EDGE NAILER(S) AND INSULATION.
4" FLANGE
1/2" HUG
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE WALL AT FLASHING PIECE INTERSECTIONS.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
PREFINISHED 24 GA. GALV. STEEL REGLETED
COUNTERFLASHING. SECURE TO SUBSTRATE WITH
GASKETED FASTENERS 12-INCHES O.C., MIN. 2
FASTENERS.
SEALANT
CUT SIDING TO WALL
2" M
IN
1" M
IN
PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.
TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE
BEHIND TURN-UP, AND SECURE.
FULLY-ADHERED EPDM FLASHING MEMBRANE
COPING CAP TERMINATION
AT END WALLS
FOR USE WHERE PARAPET WALLS AND
RELATED COPING CAPS TERMINATE
INTO VERTICAL WALLS.
PREFINISHED 24 GA. GALV. STEEL REGLETED
COUNTERFLASHING. SECURE TO SUBSTRATE WITH
GASKETED FASTENERS 12-INCHES O.C., MIN. 2
FASTENERS.
SEALANT
CUT REGLET INTO WALL
2" M
IN
1" M
IN
PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.
TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE
BEHIND TURN-UP, AND SECURE.
FULLY-ADHERED EPDM FLASHING MEMBRANE
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
NOTE: MEMBRANE MUST BE EXTENDED TO CORNERS TO PROVIDE
COMPLETE COVERAGE OF THE WALL SURFACE.
COPING CAP JOINT PROFILE
SINGLE-LOCK STANDING SEAM; FOR USE WHERE
ADJACENT COPING CAPS ARE TO BE JOINED, BUTTON PUNCH.
22 GA. GALV. STEEL CONTINUOUS CLEAT. FABRICATE AS SHOWN TO
CREATE 1/2-INCH PER FOOT SLOPE TOWARD INNER FACE. SECURE
HORIZONTAL FLANGE AND VERTICAL FACE WITH RING SHANK COATED
NAILS 6-INCHES O.C. MAX.
EXTEND FULLY-ADHERED EPDM FLASHING MEMBRANE UP AND
OVER PARAPET WALL, AND DOWN OUTSIDE FASCIA. APPLY
SEALANT TO BACK SIDE OF FLASHING MEMBRANE, AND SECURE
12" O.C. MAX.
1"
SEALANT - SEAL BOTH ENDS OF
STANDING SEAM
PARAPET WALL STEEL COPING CAP
BUTTON PUNCH
3" M
IN
PREFINISHED 24 GA. GALV. STEEL COPING CAP.
HOOK OUTSIDE FACE TO CONTINUOUS CLEAT,
AND SECURE INNER FACE WITH GASKETED
FASTENERS APPROPRIATE FOR THE
SUBSTRATE ENCOUNTERED 18-INCHES O.C.
MAX., AND WITHIN 2-INCHES OF EACH END.
JOIN ADJACENT CAP SECTIONS USING 1-INCH
HIGH, SINGLE-LOCK STANDING SEAMS.
BUTTON PUNCH BOTH ENDS.
EXISTING STRUCTURAL DECK
SPECIFIED POLYISO. INSULATION
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO
EXISTING WALL WITH PROPER SUBSTRATE FASTENERS;
TWO ROWS 24-INCHES O.C., STAGGERED
H
EI
G H
T
VA
R
IE
S;
-IN
C
H M
IN
IM
U M
NOMINAL 2-INCH THICK WOOD BLOCKING - WIDTH AS NECESSARY
TO MATCH EXISTING PARAPET WALL WIDTH. THICKNESS AS
NECESSARY TO ACHIEVE 4-INCH MINIMUM FLASHING HEIGHT.
SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A
BUILDING CORNER.
4" M
IN
8" M
IN
2" M
IN
4" M
IN
M
AX
. H
EI
G H
T
PO
SS
IB
LE
1" M
IN
PREFINISHED 24 GA. GALV. STEEL SLIP
COUNTERFLASHING. SECURE TO EXISTING
COUNTERFLASHING AS SHOWN USING GASKETED
FASTENERS 12-INCHES O.C. MAX., AND WITHIN
2-INCHES OF EACH END.
EXISTING COUNTERFLASHING
EXISTING METAL WALL SIDING - DO NOT DISTURB.
ALTERNATE COUNTERFLASHING NO. 1
FOR USE BELOW EXISTING METAL WALL SIDING WHERE 8-INCH
MINIMUM FLASHING HEIGHT CAN BE ACHIEVED.
ALTERNATE COUNTERFLASHING NO. 2
FOR USE BELOW EXISTING METAL WALL SIDING WHERE 8-INCH
MINIMUM FLASHING HEIGHT CANNOT BE ACHIEVED.
PREFINISHED 24 GA. GALV. STEEL SLIP
COUNTERFLASHING. SECURE TO EXISTING
COUNTERFLASHING AS SHOWN USING GASKETED
FASTENERS 12-INCHES O.C. MAX., AND WITHIN
2-INCHES OF EACH END.
EXISTING COUNTERFLASHING - CUT AS SHOWN.
EXISTING METAL WALL SIDING - DO NOT DISTURB.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND
WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION
BAR INSTALLATION, INSTALL MANUFACTURERS
RECOMMENDED SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF
FLASHING AND TERMINATION BAR AFTER INSTALLATION.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS
FOR THE PRESENCE OF MASONRY WEEPS AND
OTHER WALL DRAINAGE MECHANISMS. DO NOT
COVER WEEPS, OR IMPEDE THE ABILITY OF
MOISTURE TO EXIT WALL SYSTEMS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
APPROX.
1/2"
3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING
WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS
24-INCHES O.C., STAGGERED
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
APPROX.
1/2"
3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING
WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS
24-INCHES O.C., STAGGERED
SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND
WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION
BAR INSTALLATION, INSTALL MANUFACTURERS
RECOMMENDED SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF
FLASHING AND TERMINATION BAR AFTER INSTALLATION.
22 GA. GALV. STEEL CONTINUOUS CLEAT.
FABRICATE WITH A 2-INCH FLANGE. SECURE
FLANGE AND VERTICAL FACE WITH RING SHANK
COATED NAILS 12-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 6-INCHES O.C. WITHIN
10-FEET OF A BUILDING CORNER.
2" M
IN
. O
R T
O M
AT
C
H
EX
IS
TI
N G
E
LE
VA
TI
O N
W H
IC
H
EV
ER
IS
G
R
EA
TE
R
3/4"
5/8"
7- 1/
2" M
AX
. F
AC
E
3/4-INCH PLYWOOD MECHANICALLY
ATTACHED TO EXISTING WALL WITH PROPER
SUBSTRATE FASTENERS - TWO ROWS
24-INCHES O.C., STAGGERED
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
APPROX.
1/2"
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE
REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM
ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
NOTE: SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO TERMINATION BAR
INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE
PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR
AFTER INSTALLATION.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
4" FLANGE
1/2" HUG
PREFINISHED 24 GA. GALV. STEEL PERIMETER
EDGE FASCIA PIECE. FABRICATE WITH 1/2-INCH
HUG AT EDGE OF FLANGE AS SHOWN. SECURE
FLANGE WITH NAILS 3-INCHES O.C. MAX. IN TWO
STAGGERED ROWS. HOOK BOTTOM EDGE TO
CONTINUOUS CLEAT.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES
AS SHOWN AFTER COMPLETION OF WORK.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.
NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT
PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE
MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND
RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.
PERIMETER EDGE FLANGE CONFIGURATION
AND NAILING PATTERN DIAGRAM
SCALE: NONE
NOTE: THE PURPOSE OF THIS
DIAGRAM IS TO SHOW PERIMETER
EDGE FASCIA FLANGE FASTENING
PATTERNS AND NAILER
CONFIGURATION. THE ACTUAL
FASCIA CONFIGURATION, SIZE OF
NAILERS, AND NUMBER OF NAILERS
REQUIRED TO ACHIEVE THE
REQUIREMENTS SHOWN IN THE
DETAIL BELOW WILL VARY.
4"
1/2" HUG
3/
4" APPROX.
1/2"
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
EQ
U
AL
; 7
-1 /2
" M
AX
NOTE: EXTEND EPDM ROOFING MEMBRANE OVER AND DOWN
PERIMETER EDGE AS SHOWN. SECURE WITH ROOFING
NAILS AFFIXED WITH 1" DIAMETER METAL CAPS 12" O.C.
MAX.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
3" MIN.
6" MIN.
4" FLANGE
1/2" HUG1/2" MIN.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES
AS SHOWN AFTER COMPLETION OF WORK.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.
NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT
PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE
MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND
RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
PREFINISHED 24 GA. GALV. STEEL FASCIA EXTENSION PIECE. SECURE TO SUBSTRATE 12-INCHES
O.C. MAX. WITH SPECIFIED FASTENER APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED.
DECREASE FASTENER SPACING TO 6-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.
HOOK TO CONTINUOUS CLEAT AS SHOWN.
22 GA. GALV. STEEL CONTINUOUS CLEAT. SECURE WITH SPECIFIED FASTENER APPROPRIATE FOR
THE SUBSTRATE ENCOUNTERED 6-INCHES O.C. MAX.
NOMINAL 6-INCH WOOD BLOCKING - THICKNESS AS NECESSARY TO MATCH MAXIMUM
ROOF AREA INSULATION AND COVER BOARD THICKNESS WITH A CONSISTENT FINAL
NAILER ELEVATION. SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.
22 GA. GALV. STEEL CONTINUOUS CLEAT. SECURE FLANGE AND VERTICAL FACE
WITH SPECIFIED FASTENER APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED
6-INCHES O.C. MAX.
PREFINISHED 24 GA. GALV. STEEL FASCIA PIECE. FABRICATE AS SHOWN. SECURE FLANGE
WITH NAILS 3-INCHES O.C. MAX. IN TWO STAGGERED ROWS (REFER TO DIAGRAM ABOVE).
HOOK TO…
This is the start of the file's text. The full file is on GovTribe.