Attachment C - Cass Tech HS Drawings.pdf

PDF 3 MB Posted

Attached to
27-0052 FMP Series 6 Roof Replacement for Cass Tech, Emerson
Solicitation number
RFP DET 270000000151 2
Issued by
Wayne County, Detroit City, Michigan

About this file

This file consists of architectural drawings and technical specifications for a roof replacement project at Cass Technical High School in Detroit, Michigan, prepared for Detroit Public Schools. The project involves the complete replacement of existing roofing systems across multiple roof areas (A-W) totaling approximately 103,914 square feet. The scope of work includes removal of existing roof membranes down to the structural deck, inspection and repair of structural components, installation of a tapered polyisocyanurate insulation system with a base layer of 2.5 inches and tapered coverage providing 1/8-inch per foot slope, installation of a 1/2-inch high-density polyiso cover board, and application of a fully-adhered 60-mil EPDM roofing membrane with 6-inch seams. The project also requires replacement of roof drainage components, flashing materials, sealants, and coordination with existing rooftop equipment, mechanical systems, and lightning protection systems. The drawings are designated as 90% design review set documents dated August 19, 2026, prepared by Testing Engineers & Consultants of Troy, Michigan.

The specifications identify three acceptable EPDM membrane manufacturers: Carlisle, Johns Manville, and Elevate (Firestone). Contractors are required to provide an alternate price for a 20-year total system warranty on the roof system. The contract documents mandate that contractors verify existing site conditions prior to proposal submission, including building dimensions, roof area dimensions, drainage component locations, and existing roof system composition. Contractors must assume responsibility for final insulation system layout and provide a tapered insulation layout plan supplied by the insulation manufacturer. The project requires adherence to all applicable federal, state, and local building codes and regulations, with immediate notification to the owner of any conflicts between specified products and code requirements. Specific provisions address asbestos-containing material (ACM) abatement procedures, temporary displacement and reinstallation of rooftop equipment, raising of roof curbs to achieve minimum 8-inch flashing heights, and recertification of lightning protection systems following completion of work in accordance with NFPA 780 and UL 96A standards.

View the file

Other files

Show all 15

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

CLIENT

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 01 OF 06

TITLE SHEET

PROJECT LOCATION MAP

ROOF PLAN SYMBOL LEGEND:

ORD

INS

C

S SKYLIGHT CURB

CAPPED CURB

ROOF HATCH

ROOF CURB

SUPPORT CURBS

ROOF DRAIN

ROOF DRAIN WITH INSERT

OVERFLOW ROOF DRAIN

THROUGH-WALL SCUPPER

OVERFLOW ROOF SCUPPER

ORS

SANITARY VENT

TUBULAR PENETRATION

HOT STACK

PIPE CHASE BOX

PERIMETER OR CURBED EDGE

PARAPET WALL OR AREA DIVIDER

EXPANSION JOINT

GUTTER EDGE

PITCH PAN

ROOF-TO-WALL TRANSITION

AREA TRANSITION

SATELLITE DISH ON ROOF

WALKPADW

WALKWAY

SUPPLY OR CONDENSATE LINE

LADDER

SLOPE DIRECTION

RIDGE LINE

DUCT WORK

R RAISED EQUIPMENT

DOWNSPOUT SPLASHBLOCKS

SUMP AREA

DOWNSPOUTCHIMNEY

THROUGH-FASCIA SCUPPER

SCUPPER WITH CONDUCTOR BOX DETAIL NUMBER CALLOUT

SHEET NUMBER CALLOUT

SCOPE OF REPLACEMENT MAP

GENERAL NOTES:

1. DRAWINGS ARE PRODUCED AT ARCH D (24-INCH BY 36-INCH) SIZE.

PLEASE NOTE AND VERIFY THE SCALE INDICATED ON EACH DRAWING.

NOTE THAT ROOF PLANS AND OTHER PROJECT DRAWINGS PRODUCED

ON OTHER PAPER SIZES MAY NOT BE CORRECTLY SCALED.

2. ALL COMPONENTS SHOWN ON PROJECT DRAWINGS ARE NEW UNLESS

SPECIFICALLY INDICATED AS EXISTING.

3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING

PROJECT SITE CONDITIONS. THESE CONDITIONS INCLUDE, BUT ARE NOT

LIMITED TO: BUILDING DIMENSIONS AND PROPOSED PROJECT STAGING

LOCATIONS, ROOF REPLACEMENT AREA DIMENSIONS, ROOF DRAINAGE

COMPONENT LOCATIONS, ROOF PENETRATION LOCATIONS, EXISTING

ROOF SYSTEM COMPONENT MAKE-UP AND THICKNESS, AND PROJECT

REPAIR QUANTITIES (IF APPLICABLE). THE CONTRACTOR SHALL VISIT

AND BECOME FAMILIAR WITH THE SITE AND BUILDING PRIOR TO

PROPOSAL SUBMISSION. INCLUDE THE COST OF ALL WORK DESCRIBED

IN THE BIDDING DOCUMENTS AND THAT IS REQUIRED OR REASONABLY

IMPLIED TO ACHIEVE THE DESIGN INTENT OF THE BIDDING DOCUMENTS.

NOTIFY THE ROOF CONSULTANT OF ANY CONFLICTS BETWEEN EXISTING

CONDITIONS AND THE NEW WORK, OF ANY OMISSIONS OR CONFLICTS IN

THE DRAWINGS AND ANY RESTRICTIONS RELATED TO THE EXECUTION

OF THE WORK INCLUDING THE COORDINATION WITH OTHER TRADES.

4. PRODUCTS PROPOSED FOR USE AND PROJECT WORK SHALL BE IN

ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL

GOVERNING ORDINANCES, CODES AND REGULATIONS. NOTIFY THE

OWNER IMMEDIATELY OF CONFLICTS BETWEEN THE SPECIFIED

PRODUCTS AND/OR PROJECT WORK REQUIREMENTS AND CODES,

ORDINANCES AND/OR REGULATIONS.

5. IF DISCREPANCIES ARE DISCOVERED WITHIN THE PROJECT MANUAL OR

DRAWINGS; THE OWNER, NOT THE CONTRACTOR, SHALL DETERMINE

THE INTENT OF THE DESIGN AND PROVIDE CLARIFICATION. NO

ALLOWANCE SHALL BE MADE FOR CONTRACTOR MISINTERPRETATION

OR IMPLIED MISINTERPRETATION OF THE PROJECT MANUAL AND

DRAWINGS.

6. REFER TO THE PROJECT MANUAL AND ROOFING SYSTEM

MANUFACTURER WRITTEN INSTRUCTIONS FOR FURTHER CLARIFICATION

OF PROJECT REQUIREMENTS. NOTIFY THE OWNER IMMEDIATELY OF

CONFLICTS BETWEEN THE SPECIFIED DESIGN REQUIREMENTS AND THE

WRITTEN REQUIREMENTS AND RECOMMENDATIONS OF THE ROOFING

SYSTEM MANUFACTURER.

7. CLOSE AND SEAL ABANDONED OPENINGS TO MATCH EXISTING

ADJACENT SURFACES WHERE MECHANICAL, PLUMBING, AND/OR

ELECTRICAL ITEMS ARE REMOVED.

8. CONTRACTOR SHALL TAKE NORMAL PRECAUTIONS SO THAT DEBRIS,

ROOFING MATERIAL, ETC., DOES NOT FALL INTO THE BUILDING OR ON

EQUIPMENT PER SECTIONS 014000 AND 015000.

SUMMARY OF ROOF REPLACEMENT WORK - AREAS A-W

A. ASBESTOS LABORATORY ANALYSIS REPORT: REFER TO SECTION 022623 FOR INFORMATION

RELATING TO THE LOCATION OF ACM, IF APPLICABLE, WITHIN PROJECT AREAS. IF POSITIVE, REFER TO SECTIONS 013543 AND 028233 FOR PROCEDURES AND REQUIREMENTS RELATED TO

THE REMOVAL AND DISPOSAL OF NON-FRIABLE ASBESTOS RELATED TO THIS PROJECT.

B. ROOF REMOVAL AND SUBSTRATE PREPARATION: REMOVE EXISTING ROOF SYSTEM DOWN TO

THE STRUCTURAL DECK, INCLUDING ROOF MEMBRANE(S), AND UNDERLYING INSULATION,

UNDERLAYMENTS, AND ADDITIONAL ROOF MEMBRANES. INSPECT THE EXISTING STRUCTURAL

DECK, AND INFORM THE OWNER IMMEDIATELY OF OBSERVED DAMAGE AND OR

DETERIORATION. TEMPORARILY DISPLACE ROOFTOP EQUIPMENT AS NECESSARY TO

COMPLETE THE SPECIFIED WORK. REFER TO SECTION 024100.

C. AFTER ROOF REMOVAL AND INSPECTION OF THE EXISTING STRUCTURAL DECK AND PERIMETER

WOOD BLOCKING, PERFORM REPAIRS TO THE STRUCTURAL DECK, AS DETERMINED

NECESSARY BY THE OWNER. REFER TO SECTION 053123. REPLACE DAMAGED OR

DETERIORATED WOOD BLOCKING, AS DETERMINED NECESSARY BY THE OWNER. REFER TO

SECTION 061053.

D. PROVIDE REQUIRED WOOD BLOCKING WHERE INDICATED ON THE PROJECT DRAWINGS. REFER

TO SECTION 061053.

E. PROVIDE A TAPERED POLYISOCYANURATE INSULATION SYSTEM WITH AN INSULATION SYSTEM SLOPE OF 1/8-INCH PER FOOT, AND A STARTING THICKNESS OF 1/2-INCH OVER A BASE LAYER

OF 2-1/2 INCH POLYISOCYANURATE INSULATION. IF INDICATED ON THE PROJECT DRAWINGS,

PROVIDE INSULATION SADDLES AND CRICKETS WHERE SHOWN. REFER TO SECTION 072223

FOR ADDITIONAL INSULATION PRODUCT AND INSTALLATION REQUIREMENTS.

F. PROVIDE A 1/2-INCH HIGH DENSITY POLYISO COVER BOARD OVER THE UNDERLYING

INSULATION. REFER TO SECTIONS 072223 FOR ADDITIONAL PRODUCT AND INSTALLATION

REQUIREMENTS.

G. PROVIDE A FULLY-ADHERED, NOMINAL 60-MIL EPDM ROOF SYSTEM. AFTER INSTALLATION OF

SPECIFIED INSULATION AND COVER BOARD, INSTALL THE EPDM ROOFING MEMBRANE IN

BONDING ADHESIVE. PROVIDE EPDM AND SHEET METAL FLASHINGS AS SPECIFIED. PROVIDE

AN ALTERNATE PRICE FOR A 20-YEAR, “TOTAL SYSTEM WARRANTY” FOR THE ROOF SYSTEM.

REFER TO SECTIONS 075323 AND 076205 FOR PRODUCT AND INSTALLATION REQUIREMENTS.

1. ACCEPTABLE MANUFACTURERS:

a. CARLISLE

b. JOHNS MANVILLE

c. ELEVATE (FIRESTONE)

H. PROVIDE SEALANTS AT LOCATIONS INDICATED ON THE PROJECT DRAWINGS. REFER TO

SECTION 079201.

INDEX OF DRAWINGS:

SHEET 01 OF 05

SHEET 02 OF 05

SHEET 03 OF 05

SHEET 04 OF 05

SHEET 05 OF 05

SHEET 06 OF 05

TITLE SHEET

GENERAL INFORMATION SHEET 01 OF 01

ROOF PLAN - AREAS A-J, V & W

ROOF PLAN - AREAS K-U

ROOF PLAN DETAILS 01-09

ROOF PLAN DETAILS 10-18

XX

X

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

90% Design Review Set

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

08/19/2026

Cass Technical High School

2501 2nd Street Detroit, MI 48201

CLIENT

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 02 OF 06

GENERAL

INFORMATION

SHEET 01 OF 01

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

EXISTING CONDITIONS:

NOTE: THE INFORMATION BELOW IS BASED ON RANDOM, LIMITED TEST CORES

MADE INTO THE ROOFING SYSTEM. CONDITIONS AT THE TEST CORE

LOCATIONS MAY NOT BE REPRESENTATIVE OF THE ENTIRE ROOF AREA.

IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY

EXISTING ROOF SYSTEM COMPONENTS AND SLOPE.

ROOF AREAS A-S

· GRANULE SURFACE MOD-BIT WITH COATING

· 3/4-INCH WOOD FIBER

· TAPERED POLYISO

· 2-1/2 INCH POLYISO

· STEEL DECK - NO SLOPE IN DECK

PROPOSED ROOF SYSTEMS:

NOTE: REFER TO SECTION 011000 - SUMMARY OF WORK, AND RELATED PROJECT

MANUAL SECTIONS FOR ADDITIONAL PRODUCT AND INSTALLATION

REQUIREMENTS FOR THE PROJECT.

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

RECOMMENDED MAXIMUM L:W RATIOS FOR SADDLES AND CRICKETS

ROOF SLOPE SADDLE MATERIAL

SLOPE L:W RATIO

1/8 1/4 2:1

1/4 1/2 3:1

1/2 1 4:1

L

W

CRICKET DRAIN SUMP AREA

SADDLE

ROOF CURB

CRICKETS MUST BE USED ON THE UPHILL SLOPE OF

ANY CURB THAT IS GREATER THAN 24-INCHES

L

W

COVER BOARD & INSULATION ATTACHMENT REQUIREMENTS:

PROPOSED ROOF SYSTEM - ROOF AREAS A-W (APPROX. 103,914 SF.):

· FULLY-ADHERED 60-MIL EPDM WITH 6-INCH SEAMS

· 1/2-INCH HIGH DENSITY POLYISO COVERBOARD - ADHERED AS SPECIFIED

· 1/8-INCH PER FOOT TAPERED POLYISOCYANURATE INSULATION WITH A

1/2-INCH STARTIGN THICKNESS - ADHERED AS SPECIFIED

· 2-1/2 INCH POLYISOCYANURATE INSULATION - ADHERED AS SPECIFIED

· EXISTING CONCRETE DECK - NO SLOPE IN DECK

90% Design Review Set

PROJECT SPECIFIC KEY NOTES:

PROVIDE TAPERED DRAINAGE SUMPS AT ROOF DRAIN LOCATIONS INDICATED ON THE ROOF PLAN.

REFER TO DETAILS 04, 05, 06 AND SECTION 072223 FOR PRODUCT AND INSTALLATION REQUIREMENTS.

CONTRACTOR SHALL PROVIDE CONCRETE SPLASH BLOCK AT THE BASE OF DOWNSPOUT - SET

CONCRETE SPLASH BLOCK ON WALKPAD APPROVED BY THE ROOFING MEMBRANE MANUFACTURER.

INSTALL NEW INSULATION SADDLES BETWEEN ROOF DRAINS AND AT OTHER LOCATION INDICATED ON ROOF PLAN - REFER TO SECTION 072223 FOR PRODUCT AND INSTALLATION REQUIREMENTS - ADJUST

SADDLE CONFIGURATION BASED ON FIELD CONDITIONS OBSERVED.

CONTRACTOR SHALL SEAL TOP EDGE OF MEMBRANE AND TERM BAR WITH MANUFACTURERS LIQUID APPLIED FLASHING SYSTEM WHERE 8-INCH FLASHING CANNOT BE ACHIEVED - REFER TO SECTION

075323 FOR PRODUCT REQUIREMENTS.

EXISTING LIGHTNING PROTECTION SYSTEM - TEMPORARILY DISPLACE TO ALLOW FOR INSTALLATION

OF THE ROOF SYSTEM. AFTER COMPLETION OF WORK THE SYSTEM SHALL BE RECERTIFIED TO

ENSURE COMPLIANCE WITH LIGHTNING PROTECTION REQUIREMENTS.] THE COMPLETED

REINSTALLATION SHALL MEET THE REQUIREMENTS OF THE NATIONAL FIRE PROTECTION

ASSOCIATION'S (NFPA) "STANDARD FOR THE INSTALLATION OF LIGHTNING PROTECTION SYSTEMS - [LATEST EDITION], AND THE "INSTALLATION REQUIREMENTS FOR LIGHTNING PROTECTION SYSTEMS, UL 96A" OF UNDERWRITERS LABORATORIES INC. THE LIGHTNING RISK ASSESSMENT CONTAINED IN APPENDIX L OF THE NFPA 780-2004 SHALL BE PERFORMED. COORDINATE DETAILS OF ATTACHMENT OF

ROOF MOUNTED LIGHTNING ARRESTERS AND CONDUCTORS WITH ROOF MEMBRANE SYSTEM

MAUFACTURER. REFER TO SECTION 0264113 FOR PRODUCT AND INSTALLATION REQUIREMENTS.

CONTRACTOR TO RAISE CURBS AS NEEDED TO ACHIEVE A MINIMUM FLASHING HEIGHT OF 8-INCHES - RAISE ALL ELECTRICAL, PLUMBING AND MECHANICAL AS NEEDED - ALL WORK IS TO BE PERFORMED

BY LICENSED PROFESSIONAL TO PERFORM SUCH WORK.

EXISTING GAS, CONDUIT AND CONDENSATE LINES ON ROOF - TEMPORARILY DISPLACE TO ALLOW FOR

INSTALLATION OF NEW ROOF SYSTEM. PROVIDE NEW CONNECTIONS WHERE EXISTING IS

DETERIORATED - ADD NEW WHERE MISSING OR AS NEEDED FOR PROPER COMPLETE

REINSTALLATION. RE-INSTALL ON NEW PREFABRICATED SUPPORTS AND SET ON NEW WALKPADS.

ROUTE CONDENSATE LINES TO NEAREST ROOF DRAIN. NOTE THAT DISCONNECTION AND

RECONNECTION OF GAS AND CONDUIT LINES SHALL BE PERFORMED BY A CONTRACTOR LICENSED TO

PERFORM THE SPECIFIED WORK.

EXISTING OVERFLOW DRAINS - CONTRACTOR SHALL ADJUST HEIGHT OF DRAIN TO ACCOMMODATE

NEW ROOF SYSTEM THICKNESS.

A

B

C

ROOF AREAS T & U

· GRANULE SURFACE MOD-BIT

· 3/4-INCH WOOD FIBER

· TAPERED POLYISO

· 2-1/2 INCH POLYISO

· STEEL DECK - NO SLOPE IN DECK

FIELD OF ROOF PERIMETERS CORNERS

COVER BOARD

TOP AND INTERMEDIATE

INSULATION LAYER(S)

BOTTOM INSULATION

LAYER

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

12" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

6" O.C.

MECH. ATTACH WITH 12

FASTENERS PER 4' X 8'

BOARD (ONE FASTENER

PER 2.67 SF).

MECH. ATTACH WITH 24

FASTENERS PER 4' X 8'

BOARD (ONE FASTENER

PER 1.33 SF).

LOOSE-LAID

LOOSE-LAID

MECH. ATTACH WITH 32

FASTENERS PER 4' X 8'

BOARD (ONE FASTENER

PER 1.00 SF).

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

12" O.C.

ADHERED IN TWO-PART

URETHANE FOAM

ADHESIVE 3/4" BEADS

6" O.C.

ATTACHMENT FOR

STEEL DECKS

08/19/2026

Cass Technical High School

2501 2nd Street Detroit, MI 48201

D

E

F

G

H

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

R

272' 31' 31' 61'

15'

29'

212'

60'

30'

45'

14'

17'

15'

40'

360'

135'

211'

13'

40'

20'

15'

30'-6"

110' 61'

62'

20' 34'

60'

30'

27'

ORD

ORD

ROOF PLAN - AREAS A-J, V & W

CLIENT

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 03 OF 06

ROOF PLAN

AREAS A-J, V & W

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

90% Design Review Set

NOTE: TAPERED INSULATION LAYOUT

THE ROOFING CONTRACTOR IS RESPONSIBLE FOR THE FINAL INSULATION

SYSTEM LAYOUT. THE ROOFING CONTRACTOR SHALL PROVIDE A TAPERED

INSULATION LAYOUT PLAN, PROVIDED BY THE INSULATION MANUFACTURER,

PER SECTION 013300.

27'

05 TYP.

05 TYP.

05 TYP.

05 TYP.

05 TYP.

06 10

05 TYP.

05 TYP.

06 13

05 TYP.

05 TYP.

06TYP. 4

SIDES

05 TYP.

05 TYP.

05 TYP.05

05 TYP. 06

05TYP.

05 TYP.

05 TYP.

ROOF AREA A

11,007 SF.

ROOF AREA B

1,800 SF.

ROOF AREA D

915 SF.

ROOF AREA E

465 SF.

ROOF AREA F

465 SF.

ROOF AREA C

11,216 SF.

ROOF AREA W

1,240 SF.

ROOF AREA V

2,040 SF.

ROOF AREA G

435 SF.

ROOF AREA I

8,649 SF.

ROOF AREA H

2,399 SF.

ROOF AREA J

1,620 SF.

ROOF AREA C1

471 SF.

ROOF AREA X

NOT IN CONTRACT

08/19/2026

Cass Technical High School

2501 2nd Street Detroit, MI 48201

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT KEY PLAN

REPLACEMENT

AREAS

A TYP.A TYP.

A TYP.

A TYP.

A TYP.

BTYP.

C TYP.

C TYP.

C TYP.

C TYP.

CTYP.

CTYP.

F TYP.

F TYP.

F TYP.

D E

D E D E

D E

D E

D E

D ED E

H

H

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE: 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 8'

AutoCAD SHX Text

NORTH

RRRR

ROOF PLAN - AREAS K-U

CLIENT

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 04 OF 06

ROOF PLAN

AREAS K-U

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

90% Design Review Set

NOTE: TAPERED INSULATION LAYOUT

THE ROOFING CONTRACTOR IS RESPONSIBLE FOR THE FINAL INSULATION

SYSTEM LAYOUT. THE ROOFING CONTRACTOR SHALL PROVIDE A TAPERED

INSULATION LAYOUT PLAN, PROVIDED BY THE INSULATION MANUFACTURER,

PER SECTION 013300.

111'

99'

135' 55' 14'

181'

152'

71'

12'

25'

29'

42' 17'

12'

105'

36'

44'

31'

15'

75'

115'

05 TYP. 04

05 TYP.05

05 TYP.

05 TYP.

05TYP.

05TYP.

05TYP.

05TYP.

05 TYP.07

05 TYP.

05TYP.

05TYP.

05TYP.05

05TYP.

05TYP.

05TYP.

05 TYP.

05TYP.

06 12

06 12

TYP. 4

SIDES

TYP. 4

SIDES

05TYP.04

05TYP.

05TYP.

05TYP.

05TYP. 07

05TYP.

05TYP.

63'

19'

63'

19'

ROOF AREA L1

10,989 SF.

ROOF AREA Y

NOT IN CONTRACT

ROOF AREA M

3,996 SF.

ROOF AREA N

4,758 SF.

ROOF AREA W

1,240 SF.

ROOF AREA L

21,462 SF.

ROOF AREA K

10,125 SF.

ROOF AREA O

182 SF.

ROOF AREA P

370 SF.

ROOF AREA T

1,185 SF.

ROOF AREA U

1,197 SF.

ROOF AREA S

2,534 SF.

ROOF AREA R

937 SF.

08/19/2026

Cass Technical High School

2501 2nd Street Detroit, MI 48201

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT

SKYLIG

HT KEY PLAN

REPLACEMENT

AREAS

D E

D E

D E

D E

D E

D E

D E

A TYP.

A TYP.

C TYP.

A TYP.

A TYP.

A TYP.

A TYP.

A TYP.

C TYP.

C TYP.

C TYP.

C TYP.

C TYP.C TYP.

SOLAR ARAY

F TYP.

F TYP.

F TYP.

G TYP.

G TYP.

AutoCAD SHX Text

NORTH

AutoCAD SHX Text

AutoCAD SHX Text 16'

AutoCAD SHX Text 32'

AutoCAD SHX Text

SCALE: 1/16" = 1'-0"

AutoCAD SHX Text 8'

AutoCAD SHX Text 8'

NORTH

WOOD BLOCKING - IF NECESSARY TO ACHIEVE

8-INCH MINIMUM FLASHING HEIGHT. SECURE TO

SUBSTRATE 18-INCHES O.C. AND WITHIN 2-INCHES

OF EACH END.

EXISTING ROOFTOP UNIT - TEMPORARILY DISPLACE

TO ALLOW FOR INSTALLATION OF NEW ROOF

SYSTEM AND RELATED FLASHING COMPONENTS.

REINSTALL TO ORIGINAL POSITION AFTER

COMPLETION OF WORK. RE-SECURE TO EXISTING

CURB WITH GASKETED FASTENERS 12-INCHES O.C.

MAX., AND WITHIN 2-INCHES OF EACH CORNER.

CURB INSULATION - IF EXISTING

CURB IS INSULATED, AND

EXISTING INSULATION CANNOT BE

SALVAGED, PROVIDE CURB

INSULATION TO MATCH EXISTING.

PREFINISHED 24 GA. GALV. STEEL

SURFACE-MOUNTED

COUNTERFLASHING. SECURE TO

EXISTING CURB COUNTERFLASHING

AS SHOWN USING GASKETED

FASTENERS 12-INCHES O.C. MAX.,

AND WITHIN 2-INCHES OF EACH END.

SELF-ADHERING MEMBRANE

COMPATIBLE WITH EXISTING

SUBSTRATE(S)

REFER TO DETAILS BELOW FOR

FLASHING REQUIREMENTS.

ALT. COUNTERFLASHING NO. 2

FOR USE WHERE APPROVED AND WHERE

EXISTING CURB IS SEPARATED FROM THE

EXISTING ROOFTOP PENETRATION

BUTYL TAPE - INSTALL BEHIND

COUNTERFLASHING

SEALANT

NOTE: SECURE TOP EDGE OF FLASHING USING AN

ALUMINUM TERMINATION BAR SECURED

12-INCHES O.C., MAX., AND WITHIN

2-INCHES OF EACH END. PRIOR TO

TERMINATION BAR INSTALLATION, INSTALL

MANUFACTURERS RECOMMENDED

SEALANT BEHIND FLASHING WHERE

TERMINATION BAR WILL BE PLACED. SEAL

TOP EDGE OF FLASHING AND TERMINATION

BAR AFTER INSTALLATION.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING

CORNERS FOLLOWING THE

RECOMMENDATIONS AND REQUIREMENTS

OF THE ROOFING MEMBRANE

MANUFACTURER. PROVIDE "T-JOINT

COVERS" AT THE BASE OF THE CURB AT

FLASHING PIECE INTERSECTIONS.

ALT. VERTICAL MEMBRANE TERMINATION

FOR USE WHERE HORIZONTAL TERMINATION OF

EPDM MEMBRANE IS NOT POSSIBLE

4" M

IN

4" M

IN

8" M

IN

FL

AS

H

IN

G H

EI

G

H T

NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS

OF ELECTRICAL, PLUMBING OR

MECHANICAL CONNECTIONS RELATED TO

THE DISPLACEMENT AND RE-INSTALLATION

OF ROOFTOP UNITS SHALL BE PERFORMED

BY A CONTRACTOR LICENSED TO PERFORM

SUCH WORK. COORDINATE THIS WORK

WITH THE OWNER.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT

SHOWN FOR CLARITY.

SPECIFIED POLYISO. INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING STRIP WITH

FACTORY-LAMINATED SEAM TAPE. PRIME EPDM

MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 6-INCHES O.C. MAX.

EPDM MEMBRANE, 8" MIN. HEIGHT, FULLY

ADHERED TO CURB. REFER TO NOTE

REGARDING SECUREMENT OF MEMBRANE.

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING STRIP WITH

FACTORY-LAMINATED SEAM TAPE. PRIME EPDM

MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

BATTEN STRIP OR FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

1-1/4" 1/2"

APPR

O

X.

2-3/4"

EPDM MEMBRANE, FULLY ADHERED TO CURB. 8" MIN.

HEIGHT, REFER TO NOTE REGARDING SECUREMENT

OF FLASHING.

APPROX.

1/2"

ALT. VERTICAL TERMINATION -

TWO PIECE FLASHING

FOR USE WHERE HORIZONTAL TERMINATION OF

EPDM MEMBRANE IS NOT POSSIBLE

APPROX.

1/2"

EPDM ROOFING MEMBRANE

SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER TO

UNDERLYING EPDM ROOF MEMBRANE AND OVERLYING

EPDM FLASHING MEMBRANE PRIOR TO APPLICATION.

1-1/4" 1/2"

APPR

O

X.

2"

PRESSURE-SENSITIVE OUTERSEAM FLASHING;

MINIMUM 5-INCH WIDTH. SEAL EDGES AS SHOWN.

EPDM ROOFING MEMBRANE

SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER

TO UNDERLYING EPDM ROOF MEMBRANE

AND OVERLYING EPDM FLASHING

MEMBRANE PRIOR TO APPLICATION.

BATTEN STRIP OR FASTENERS AND 2-INCH

PLATES, 12-INCHES O.C. MAX.

PRESSURE-SENSITIVE OUTERSEAM

FLASHING; MIN. 5-INCH WIDTH. SEAL

EDGES AS SHOWN.

4" M

IN

WRAP EPDM MEMBRANE FLASHING OVER

THE TOP OF THE CURB AND SECURE TO

THE INSIDE OF THE CURB WITH 1" METAL

CAP NAILS AT 6" O.C. MAXIMUM.

MEMBRANE SECUREMENT

ALT. TWO-PIECE FLASHING

PREFINISHED 24 GA. GALV.

STEEL SLIP COUNTERFLASHING.

SECURE TO EXISTING CURB

COUNTERFLASHING AS SHOWN

USING GASKETED FASTENERS

12-INCHES O.C. MAX., AND

WITHIN 2-INCHES OF EACH END.

EXISTING ROOFTOP UNIT

COUNTERFLASIHNG

REFER TO DETAILS BELOW FOR

FLASHING REQUIREMENTS.

ALT. COUNTERFLASHING NO. 1

FOR USE WHERE APPROVED AND WHERE EXISTING

ROOFTOP UNIT CANNOT BE DISPLACED TO ALLOW FOR

FLASHING, OR WHERE GAP BETWEEN EXISTING

ROOFTOP UNIT COUNTERFLASHING AND CURB IS TOO

NARROW TO ACCOMMODATE FLASHING

4" M

IN

8" M

IN

FL

AS

H

IN

G H

EI

G

H T

EXIST. ROOFTOP PENETRATION

EPDM FLASHING, 8" MIN. HEIGHT, FULLY

ADHERED TO CURB. REFER TO NOTE

REGARDING SECUREMENT OF MEMBRANE.

ALT. NOTE:

ALT. SECUREMENT

2-3/4"

8" M

IN

IM

U M

H

EI

G H

T

NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF ELECTRICAL,

PLUMBING OR MECHANICAL COMPONENTS RELATED TO

THE DISPLACEMENT AND RE-INSTALLATION OF ROOFTOP

UNITS SHALL BE PERFORMED BY A CONTRACTOR LICENSED

TO PERFORM SUCH WORK. COORDINATE THIS WORK WITH

THE OWNER.

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS

FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS

OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE

"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING

PIECE INTERSECTIONS.

NOTE: APPLY WATER CUT OFF MASTIC TO THE BACKSIDE OF

FLASHING PRIOR TO COUNTERFLASIHNG INSTALLATION.

USE COUNTERFLASHING AS SECUREMENT PIECE FOR

FLASHING AS SHOWN.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

APPROX.

1/2"

EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO

NOTE REGARDING SECUREMENT OF FLASHING.

REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED

SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.

EXISTING ROOF HATCH ON CURB -

RAISE TO ACCOMMODATE NEW

ROOF SYSTEM ELEVATION, AND

RE-SECURE FLANGE TO WOOD

BLOCKING AS SHOWN. PROVIDE

INTERIOR FINISH REPAIRS AS

NEEDED TO ACCOMMODATE

RAISING OF CURB.

NOMINAL WOOD BLOCKING.

THICKNESS TO MATCH EXISTING

COVER BOARD AND INSULATION

THICKNESS; WIDTH GREATER

THAN ROOF HATCH CURB AND

CURB FLANGE. SECURE TO

SUBSTRATE 18-INCHES O.C.

WITH SPECIFIED FASTENERS

APPROPRIATE FOR THE

SUBSTRATE ENCOUNTERED.

PREFINISHED 24 GA. GALV.

STEEL SLIP COUNTERFLASHING.

SECURE TO EXISTING CURB

COUNTERFLASHING AS SHOWN

USING GASKETED FASTENERS

12-INCHES O.C. MAX., AND

WITHIN 2-INCHES OF EACH END.

APPLY SEALANT TO BACKSIDE

OF COUNTERFLASHING PRIOR

TO INSTALLATION.

NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF ELECTRICAL,

PLUMBING OR MECHANICAL COMPONENTS RELATED TO

THE DISPLACEMENT AND RE-INSTALLATION OF ROOFTOP

UNITS SHALL BE PERFORMED BY A CONTRACTOR LICENSED

TO PERFORM SUCH WORK. COORDINATE THIS WORK WITH

THE OWNER.

4" M

IN

8" M

IN

IM

U M

H

EI

G H

T

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS

FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS

OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE

"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING

PIECE INTERSECTIONS.

NOTE: SECURE TOP EDGE OF FLASHING WITH 1-INCH BY 1/8-INCH

ALUMINUM ANCHOR BAR SECURED 12-INCHES O.C. MAX.

AND WITHIN 2-INCHES OF EACH END. APPLY WATER CUT

OFF MASTIC TO THE BACKSIDE OF FLASHING PRIOR TO

ANCHOR BAR INSTALLATION. APPLY SEALANT TO TOP

EDGE OF FLASHING AND ANCHOR BAR AFTER COMPLETION

OF WORK. IF SUBSTRATE IS WOOD, NAILS AFFIXED WITH

1-INCH METAL CAPS, 6-INCHES O.C. MAX., MAY BE USED IN

LIEU OF TERMINATION BAR.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO

NOTE REGARDING SECUREMENT OF FLASHING.

REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED

SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.

APPROX.

1/2"

APPROX.

1/2"

EPDM ROOFING MEMBRANE

SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER

TO UNDERLYING EPDM ROOF MEMBRANE

AND OVERLYING EPDM FLASHING

MEMBRANE PRIOR TO APPLICATION.

2"

PRESSURE-SENSITIVE OUTERSEAM

FLASHING; MINIMUM 5-INCH WIDTH.

SEAL EDGES AS SHOWN.

ALT. TWO-PIECE FLASHING

EPDM FLASHING, 8" MIN. HEIGHT,

FULLY ADHERED TO CURB. REFER

TO NOTE REGARDING SECUREMENT

OF MEMBRANE.

ALT. VERTICAL MEMBRANE TERMINATION

FOR USE WHERE HORIZONTAL TERMINATION OF

EPDM MEMBRANE IS NOT POSSIBLE

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING STRIP WITH

FACTORY-LAMINATED SEAM TAPE. PRIME EPDM

MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

BATTEN STRIP OR FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

1-1/4" 1/2"

APPR

O

X.

2-3/4"

EPDM MEMBRANE, FULLY ADHERED TO CURB. 8" MIN.

HEIGHT, REFER TO NOTE REGARDING SECUREMENT

OF FLASHING.

ALT. VERTICAL TERMINATION -

TWO PIECE FLASHING

FOR USE WHERE HORIZONTAL TERMINATION OF

EPDM MEMBRANE IS NOT POSSIBLE

1-1/4" 1/2"

APPR

O

X.

2-3/4"

EPDM ROOFING MEMBRANE

SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER TO

UNDERLYING EPDM ROOF MEMBRANE AND

OVERLYING EPDM FLASHING MEMBRANE PRIOR

TO APPLICATION.

BATTEN STRIP OR FASTENERS AND 2-INCH

PLATES, 12-INCHES O.C. MAX.

PRESSURE-SENSITIVE OUTERSEAM

FLASHING; MIN. 5-INCH WIDTH. SEAL

EDGES AS SHOWN.

TWO PIECE- PREFINISHED 24 GA. GALV. STEEL

CURB CAP. SECURE VERTICAL FACE OF CAP

WITH GASKETED FASTENERS, 12-INCHES O.C.

MAX., AND WITHIN 2-INCHES OF EACH END.

EXISTING UNIT ON CURB SUPPORTS.

TEMPORARILY DISPLACE TO ALLOW FOR

INSTALLATION OF NEW ROOF SYSTEM AND

RELATED FLASHING. REINSTALL ON NEW SHEET

METAL CAP AFTER COMPLETION OF WORK.

EXISTING SUPPORT CURB

EXISTING WOOD BLOCKING TO MATCH SUPPORT

CURB LENGTH AND WIDTH

LCC

TAPERED POLYISOCYANURATE INSULATION, AND/OR

TAPERED EDGE STRIP(S) AS NECESSARY TO RESULT IN A

8-FOOT BY 8-FOOT MINIMUM TAPERED ROOF DRAIN SUMP

AREA WITH A MINIMUM SLOPE OF 1/4-INCH PER FOOT.

EXISTING ROOF DRAIN ASSEMBLY. CLEAN BOWL FREE OF ALL

EXISTING FLASHING MATERIALS AND BITUMINOUS RESIDUE PRIOR

TO INSTALLATION OF EPDM ROOFING MEMBRANE AND

MANUFACTURER'S RECOMMENDED SEALANT. INSPECT DRAIN

BOWL, CLAMPING RING, AND OTHER ASSEMBLY COMPONENTS FOR

DAMAGE. REPLACE DAMAGED COMPONENTS AS NECESSARY PER

SECTION 024100.

EXISTING ROOF DRAIN STRAINER. REMOVE AND DISCARD

DAMAGED, BROKEN OR PLASTIC-TYPE STRAINER(S).

REPLACE DISCARDED STRAINERS WITH CAST IRON

STRAINERS. REFER TO SECTION 024100.

PLAN VIEW OF ROOF SUMP AREA

SCALE: NONE

TAPERED INSULATION/EDGE STRIPS AS NEEDED

TO RESULT IN 8'-0" X 8'-0" SUMP AREA

ROOF DRAIN

NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING

RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE

CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN

FLASHING COMPONENTS.

CUT DRAINAGE HOLE IN MEMBRANE MIN. 1/2" GREATER

THAN DRAIN PIPE DIAM. ON ALL SIDES

EXTEND MEMBRANE 1" MIN.

BEYOND CLAMPING RING

MANUFACTURER'S RECOMMENDED SEALANT. INSTALL ONE TUBE,

MINIMUM, UNDER EPDM ROOFING MEMBRANE AT CLAMPING RING,

CONTINUOUS BEAD - TO ROOF DRAIN ASSEMBLY INTERSECTION.

IN

ST

AL

L

TA

PE

R

ED

P O

LY

IS

O C

YA

N

U R

AT

E

IN

SU

LA

TI

O N

A N

D /O

R T

AP

ER

ED

E

D G

E

ST

R

IP

T O

R

ES

U

LT

IN

' x

' S U

M P

AR

EA

(T

YP

APPROX. 4'-0" - REFER TO NOTE ABOVE REGARDING ROOF SUMP AREA

CONSTRUCTION AND SLOPE REQUIREMENTS

IN

ST

AL

L

TA

PE

R

ED

P O

LY

IS

O C

YA

N

U R

AT

E

IN

SU

LA

TI

O N

A N

D /O

R T

AP

ER

ED

E

D G

E

ST

R

IP

T O

R

ES

U

LT

IN

' x

' S U

M P

AR

EA

(T

YP

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

EXISTING STRUCTURAL DECK

SPECIFIED POLYISOCYANURATE INSULATION

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

NOTE: IF FIELD SEAM EDGE IS WITHIN 9" OF DRAIN COMPRESSION

RING, EPDM TARGET PATCH REQUIRED.

PLAN VIEW OF ROOF SUMP AREA

SCALE: NONE

ROOF DRAIN

NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING

RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE

CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN

FLASHING COMPONENTS.

IN

ST

AL

L

TA

PE

R

ED

P O

LY

IS

O C

YA

N

U R

AT

E

IN

SU

LA

TI

O N

A N

D /O

R T

AP

ER

ED

E

D G

E

ST

R

IP

T O

R

ES

U

LT

IN

' W

ID

E M

IN

. S

U M

P

AR

EA

(T

YP

. A

LL

S

ID

ES

NOTE: FIELD MEMBRANE SEAMS MUST NOT RUN THRU ROOF SUMP

AREA.

LCC

LCC

EXISTING ROOF DRAIN ASSEMBLY. CLEAN BOWL FREE OF

ALL EXISTING FLASHING MATERIALS AND BITUMINOUS

RESIDUE PRIOR TO INSTALLATION OF EPDM ROOFING

MEMBRANE AND MANUFACTURERS RECOMMENDED

SEALANT. INSPECT DRAIN BOWL, CLAMPING RING, AND

OTHER ASSEMBLY COMPONENTS FOR DAMAGE. REPLACE

DAMAGED COMPONENTS AS NECESSARY PER SECTION

024100.

EXISTING ROOF DRAIN STRAINER. REMOVE AND DISCARD

DAMAGED, BROKEN OR PLASTIC-TYPE STAINER(S).

REPLACE DISCARDED STRAINERS WITH CAST IRON

STRAINERS. REFER TO SECTION 024100.

MANUFACTURERS RECOMMENDED SEALANT. INSTALL ONE

TUBE, MINIMUM, CONTINUOUS BEAD, UNDER EPDM ROOFING

MEMBRANE AT CLAMPING RING - TO ROOF DRAIN ASSEMBLY

INTERSECTION.

EXISTING STRUCTURAL DECK

SPECIFIED POLYISOCYANURATE INSULATION

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

MIN. 2'-0" - REFER TO NOTE ABOVE REGARDING ROOF SUMP AREA

CONSTRUCTION AND SLOPE REQUIREMENTS

EXISTING OVERFLOW ROOF DRAIN ASSEMBLY. CLEAN

BOWL FREE OF ALL EXISTING FLASHING MATERIALS AND

BITUMINOUS RESIDUE PRIOR TO INSTALLATION OF EPDM

ROOFING MEMBRANE AND MANUFACTURERS

RECOMMENDED SEALANT. INSPECT DRAIN BOWL,

CLAMPING RING, AND OTHER ASSEMBLY COMPONENTS FOR

DAMAGE. REPLACE DAMAGED COMPONENTS AS

NECESSARY PER SECTION 024100.

OVERFLOW ROOF DRAIN

EXISTING DRAIN SUMP PAN

INSTALL TAPERED POLYISOCYANURATE

INSULATION AND/OR TAPERED EDGE STRIP TO

RESULT IN 2' WIDE MIN. SUMP AREA (TYP. ALL SIDES)

EXISTING DRAIN SUMP PAN

LCC

EPDM ROOFING MEMBRANE

FIELD VERIFY SIZE OF

SCUPPER BOX. MINIMUM

SIZE OF SCUPPER BOX SHALL

MATCH EXISTING.

3" M

IN

1" M

IN

FI

EL

D V

ER

IF

Y

SI

ZE

O

F

SC

U

PP

ER

B

O X.

M

IN

IM

U

M S

IZ

E

O F

SC

U

PP

ER

B O

X

SH

AL

L

M

AT

C H

E

XI

ST

IN

G

. NOTE: ADJUST SCUPPER

OPENING ELEVATION AS

NECESSARY TO RESULT IN

A CONDITION THAT IS

FLUSH WITH THE TOP

ELEVATION OF THE

SPECIFIED COVER BOARD

AND INSULATION.

NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK

AREA USING SOLVENTS AND WIRE BRUSH; REMOVING DIRT,

OIL, GREASE, AND OTHER CONTAMINANTS FROM THE

WORK AREA. TIN THE WORK AREA BY APPLYING ACID

(FLUX). PERFORM SOLDERING WORK. AFTER COMPLETION

OF WORK, REMOVE EXCESS ACID (FLUX) FROM THE WORK

AREA.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT

SHOWN FOR CLARITY.

NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL

RECEIVE PRESSURE SENSITIVE OUTER SEAM

FLASHING PRIOR TO APPLICATION.

NOTE: TURN FLASHING INTO SCUPPER SLEEVE MIN.

1-1/2 INCHES ON ALL SIDES.

PLAN VIEW OF TAPERED AREA

AT SCUPPER

TAPERED INSULATION/EDGE

STRIPS AS NEEDED TO RESULT

IN 4'-0" X 8'-0" SUMP AREA WITH

MINIMUM 1/4-INCH PER FOOT

SLOPE

SCUPPER OPENING 8'-0" MINIMUM

FIELD VERIFY

SCUPPER

DIMENSION

WALL OR PERIMETER

EDGE

4' -0

" M

IN

IM

U

M

WOOD BLOCKING (IF NECESSARY) TO MATCH

COVER BOARD AND INSULATION THICKNESS.

SECURE TO SUBSTRATE 18-INCHES O.C. MAX.,

AND WITHIN 2-INCHES OF EACH END.

FIELD

VERIFY

SCUPPER

DIMENSIONS

SEALANT

1" M

IN

ENLARGED REGLET

DETAIL

SCALE: NONE

CUT REGLET INTO WALL

AS SHOWN

SEALANT

PREFINISHED 24 GA. GALV.

STEEL COUNTERFLASHING,

SPRING-LOCKED INTO REGLET

AND SECURED WITH GASKETED

FASTENERS APPROPRIATE FOR

THE SUBSTRATE 12-INCHES O.C.

MAX.

FU

LL W

ID

TH

O F M

ASO

N

R Y

G R

O U

T JO

IN

T

APPR

O

X.

1-1/4"

APPROX. 1"

DEEP

WALL FLASHING AND

CONFIGURATION WILL VARY.

REFER TO APPLICABLE

FLASHING DETAIL FOR

FLASHING REQUIREMENTS.

TIE-IN SCUPPER FLASHING TO

ADJACENT WALL FLASHING AS

NECESSARY.

PRESSURE-SENSITIVE OUTER SEAM

FLASHING - 5-INCH OR 6-INCH WIDTH.

PRESSURE-SENSITIVE OUTER SEAM

FLASHING - 9-INCH WIDTH. SEAL EDGES AS

SHOWN AFTER COMPLETION OF WORK.

22 GA. STAINLESS STEEL SCUPPER LINER. FABRICATE WITH

4-INCH FLANGES ON ALL SIDES. SOLDER ALL LAPS AND

SEAMS WATERTIGHT - REFER TO NOTE REGARDING

SOLDERING PROCEDURES. SECURE FLANGES TO

SUBSTRATE, 4" O.C. MAX FASTENER SPACING. APPLY

CONTINUOUS BEAD OF MFR. RECOMMENDED SEALANT

BETWEEN SCUPPER FLANGE AND EXISTING STRUCTURE.

PREFINISHED 24 GA. GALV. STEEL DOWNSPOUT RECEIVER

PIECE - SECURE AND SEAL TO BOTTOM OF SCUPPER BOX AS

SHOWN.

PREFINISHED 24 GA. GALV. STEEL RECTANGULAR DOWNSPOUT.

FABRICATE AND INSTALL DOWNSPOUTS IN ACCORDANCE WITH

“SMACNA ARCHITECTURAL SHEET METAL MANUAL, 7TH EDITION.

SECURE DOWNSPOUT TO WALL WITH BRACKETS AND

FASTENERS APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED.

TERMINATE BOTTOM OF DOWNSPOUT TO MATCH EXISTING.

PREFINISHED 24 GA. GALV. STEEL CONDUCTOR BOX.

SECURE TO SUBSTRATE AS SHOWN WITH FASTENERS

APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED.

SCUPPER

LINER DETAIL

SCALE: NONE

4" MIN.

SCUPPER LINER

SCUPPER OPENING

4" MIN.

4" MIN.

MANUFACTURER'S

ACCEPTED FASTENERS,

3" O.C. MAX.

4" MIN.

4" MIN. 1/2" MIN. TAPERED POLYISOCYANURATE INSULATION, AND/OR TAPERED EDGE STRIP(S)

AS NECESSARY TO RESULT IN A 4-FOOT BY 8-FOOT MINIMUM TAPERED AREA AT

SCUPPER WITH A MINIMUM SLOPE OF 1/4-INCH PER FOOT.

EPDM ROOFING MEMBRANE

EXISTING STRUCTURAL DECK

SPECIFIED POLYISO.

INSULATION

COVER BOARD - 1/2-INCH

THICK

CL

NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK AREA USING SOLVENTS

AND WIRE BRUSH; REMOVING DIRT, OIL, GREASE, AND OTHER CONTAMINANTS FROM

THE WORK AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX). PERFORM

SOLDERING WORK. AFTER COMPLETION OF WORK, REMOVE EXCESS ACID (FLUX)

FROM THE WORK AREA.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

CL

MIN. 1" AIR

GAP OR MATCH

EXIST. - WHICHEVER

IS GREATER

4" M

IN

8" M

IN

. F

LA

SH

IN

G

H

EI

G H

T

FIELD-FABRICATED

FLASHING

HOT STACK

NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL

RECEIVE PRESSURE SENSITIVE OUTER SEAM

FLASHING PRIOR TO APPLICATION.

3" MIN3" MIN

2 1/2"

NOTE: WHEN OUTSIDE DIAMETER OF THE PIPE

EXCEEDS 18", ADDITIONAL FIELD MEMBRANE

SECUREMENT REQUIRED. REFER TO

MANUFACTURER'S DETAILS.

PRESSURE-SENSITIVE

FLASHING - 12-INCH WIDTH.

PRESSURE-SENSITIVE

FLASHING - 9-INCH WIDTH.

PRESSURE-SENSITIVE

FLASHING - 5 OR 6-INCH

WIDTH.

PRESSURE-SENSITIVE

OUTERSEAM FLASHING;

6-INCH WIDTH. SEAL

EDGES AS SHOWN.

PRE-FABRICATED

BOOT FLASHING

EXISTING TUBULAR

PENETRATION

PIPE EXTENSION (IF NECESSARY) TO

ACHIEVE 8" MIN. FLASHING HEIGHT.

PROVIDE SEALANT AT INTERSECTION

BETWEEN EXISTING TUBULAR

PENETRATION AND EXTENSION.

24 GA. STAINLESS STEEL STORM COLLAR

SOLDER ALL LAPS AND SEAMS WATERTIGHT.

REFER TO NOTE REGARDING SOLDERING.

INSTALL BUTYL TAPE BEHIND COLLAR AS

SHOWN PRIOR TO INSTALLATION OF CLAMP.

SEAL TOP OF HOOD AS SHOWN.

SEALANT - TYP

STAINLESS STEEL CLAMPING

BAND

STAINLESS STEEL CLAMPING BAND.

PRIOR TO INSTALLATION, APPLY

MANUFACTURERS RECOMMENDED

SEALANT BEHIND EPDM FLASHING.

SEAL TOP OF FLASHING AND BAND

AFTER INSTALLATION.

EXISTING HIGH-TEMPERATURE

TUBULAR PENETRATION

PRESSURE-SENSITIVE FLASHING - 12-INCH

WIDTH.

PRESSURE-SENSITIVE FLASHING - 9-INCH

WIDTH.

PRESSURE-SENSITIVE FLASHING - 5 OR

6-INCH WIDTH.

PRESSURE-SENSITIVE OUTERSEAM

FLASHING; 6-INCH WIDTH. SEAL EDGES

AS SHOWN.

SEALANT - TYP

STAINLESS STEEL

CLAMPING BAND

SPECIFIED POLYISOCYANURATE INSULATION - TYP.

EXISTING STRUCTURAL DECK - TYP.

COVER BOARD - 1/2-INCH THICK - TYP.

EPDM ROOFING MEMBRANE - TYP.

24 GA. STAINLESS STEEL STORM COLLAR

SOLDER ALL LAPS AND SEAMS

WATERTIGHT. REFER TO NOTE

REGARDING SOLDERING. INSTALL BUTYL

TAPE BEHIND COLLAR AS SHOWN PRIOR

TO INSTALLATION OF CLAMP. SEAL TOP

OF HOOD AS SHOWN.

24 GA. STAINLESS STEEL FLANGED

SLEEVE. SOLDER ALL LAPS AND

SEAMS WATERTIGHT. REFER TO

NOTE REGARDING SOLDERING.

SECURE TO STRUCTURAL DECK AS

SHOWN.

NOTE: EXISTING FLANGED SLEEVE

COMPONENTS DETERMINED TO BE

IN GOOD CONDITION AND FREE OF

BITUMINOUS CONTAMINATION MAY

BE CONSIDERED FOR RE-USE.

POURABLE SEALER - SLOPE TO ALLOW FOR PROPER DRAINAGE.

NON-SHRINK GROUT - FILL TO 2" BELOW RIM OF PITCH PAN.

EXISTING IRREGULAR PENETRATION - SIZE AND SHAPE VARIES.

NOTE: DO NOT USE PITCH PANS AT TUBULAR PENETRATIONS

WITHOUT PRIOR OWNER APPROVAL.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

4" M

IN

NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK

AREA USING SOLVENTS AND WIRE BRUSH; REMOVING DIRT,

OIL, GREASE, AND OTHER CONTAMINANTS FROM THE WORK

AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX).

PERFORM SOLDERING WORK. AFTER COMPLETION OF

WORK, REMOVE EXCESS ACID (FLUX) FROM THE WORK

AREA.

AT LOCATIONS WHERE POSSIBLE, PROVIDE A 24 GA. STAINLESS

STEEL JUNCTION/FLASHING BOX. FABRICATE BOX WITH A SLOPED

TOP TO SHED WATER. SOLDER ALL LAPS AND SEAMS WATERTIGHT.

SEAL PENETRATION EXIT OPENINGS WATERTIGHT.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

PRESSURE-SENSITIVE FLASHING - WIDTH AS NECESSARY TO RESULT

IN CONDITION SHOWN.

PRESSURE-SENSITIVE OUTERSEAM FLASHING; WIDTH AS NECESSARY TO

RESULT IN CONDITION SHOWN. SEAL EDGES AS SHOWN.

NOMINAL 6-INCH WOOD BLOCKING AS NECESSARY TO MATCH COVER

BOARD AND INSULATION THICKNESS. SECURE TO SUBSTRATE

18-INCHES O.C. MAX., AND WITHIN 2-INCHES OF EACH END.

4" MIN.

24 GA. STAINLESS STEEL PITCH PAN WITH 6-INCH FLANGE AND ROUNDED

CORNERS. SOLDER ALL SEAMS AND LAPS WATERTIGHT - REFER TO NOTE

REGARDING SOLDERING.

2" MIN. ALL SIDES

NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL

RECEIVE PRESSURE SENSITIVE OUTER SEAM

FLASHING PRIOR TO APPLICATION..

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS

FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS

OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE

"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING

PIECE INTERSECTIONS.

EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER

TO NOTE ABOVE REGARDING SECUREMENT OF FLASHING.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

PLAN VIEW OF THROUGH ROOF PIPE CURB

SCALE: NONE

4" M

IN

8" M

IN

NOMINAL WOOD BLOCKING - THICKNESS AS NECESSARY TO

MATCH MAXIMUM ROOF AREA INSULATION AND COVER

BOARD THICKNESS WITH A CONSISTENT FINAL NAILER

ELEVATION.

COMPRESSIBLE/BATT INSULATION AS SPECIFIED

REMOVABLE SHEET METAL COUNTERFLASHING

FLEXIBLE INSULATION RETAINER ATTACHED TO TOP OF CURB

SHEET METAL FLASHING RECIEVER

SLOPE PIPES DOWN AND AWAY FROM HOOD

SHEET METAL OR FLEX-TUBE COLLAR

SEALANT AS SPECIFIED

SHEET METAL ENCLOSURE- CROSS BREAK OR SLOPE FOR

DRAINAGE

REINFORCED PERIMETER FASTENING STRIP

WITH FACTORY-LAMINATED SEAM TAPE.

PRIME MEMBRANE PRIOR TO APPLICATION

TO REINFORCED FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 12-INCHES

O.C. MAX.

CLIENT

PROFESSIONAL

PROJECT

DESCRIPTIONDATE

ISSUE

Drawn By: PD

Checked By: SH

SHEET TITLE

File Name:

STAMP

SHEET 05 OF 06

ROOF PLAN

DETAILS 01-09

Testing Engineers & Consultants

1343 Rochester Road Troy, MI 48083

DETAIL 01 -

SCALE: NONE

ROOF CURB FLASHING DETAIL 02 -

SCALE: NONE

ROOF HATCH CURB FLASHING DETAIL 03 -

SCALE: NONE

SUPPORT CURB FLASHING

DETAIL 04 -

SCALE: NONE

DETAIL 05 -

SCALE: NONE

DETAIL 06 -

SCALE: NONE

THROUGH-WALL SCUPPER FLASHING

Detroit Public Schools

3011 W. Grand Blvd Detroit, MI 48202

ROOF DRAIN FLASHING ROOF DRAIN FLASHING

90% Design Review Set08/19/2026

Cass Technical High School

2501 2nd Street Detroit, MI 48201

DETAIL 07 -

SCALE: NONE

DETAIL 08 -

SCALE: NONE

DETAIL 09 -

SCALE: NONE

PIPE CHASE FLASHING PITCH PAN LASHING TUBULAR PENETRATION FLASHING

AutoCAD SHX Text Copyright 1997,1998,1999 United States Postal Service

AutoCAD SHX Text Copyright 1997,1998,1999 United States Postal Service

Copyright 1997,1998,1999 United States Postal Service

2" M

IN

. O

R T

O M

AT

C

H

EX

IS

TI

N G

E

LE

VA

TI

O N

W H

IC

H

EV

ER

IS

G

R

EA

TE

R

3/4"

5/8"

7- 1/

2" M

AX

. F

AC

E

APPROX.

1/2"

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE

REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM

ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.

NOTE: SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN

2-INCHES OF EACH END. PRIOR TO TERMINATION BAR

INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED

SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE

PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR

AFTER INSTALLATION.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE

PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE

MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY

OF MOISTURE TO EXIT WALL SYSTEMS.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

22 GA. GALV. STEEL CONTINUOUS CLEAT.

FABRICATE WITH A 2-INCH FLANGE. SECURE

FLANGE AND VERTICAL FACE WITH RING SHANK

COATED NAILS 12-INCHES O.C. MAX. DECREASE

FASTENER SPACING TO 6-INCHES O.C. WITHIN

10-FEET OF A BUILDING CORNER.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

COVER BOARD - MIN. 1/2-INCH THICK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING STRIP

WITH FACTORY-LAMINATED SEAM TAPE.

PRIME MEMBRANE PRIOR TO APPLICATION

TO REINFORCED FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 12-INCHES

O.C. MAX.

EPDM FLASHING MEMBRANE, FULLY-ADHERED

TO WALL REFER TO NOTE REGARDING

SECUREMENT OF FLASHING.

PREFINISHED 24 GA. GALV. STEEL PERIMETER

EDGE FASCIA PIECE. FABRICATE WITH 1/2-INCH

HUG AT EDGE OF FLANGE AS SHOWN. SECURE

FLANGE WITH NAILS 3-INCHES O.C. MAX. IN TWO

STAGGERED ROWS. HOOK BOTTOM EDGE TO

CONTINUOUS CLEAT.

3/4-INCH PLYWOOD MECHANICALLY

ATTACHED TO EXISTING WALL WITH

PROPER SUBSTRATE FASTENERS - TWO

ROWS 24-INCHES O.C., STAGGERED

EXISTING STRUCTURAL DECK

SPECIFIED POLYISOCYANURATE INSULATION

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES

AS SHOWN AFTER COMPLETION OF WORK.

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.

NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT

PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE

MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND

RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.

TAPERED POLYISOCYANURATE INSULATION. CUT TO MATCH

CONDITION SHOWN.

CREATE A 3-FOOT ENHANCED DRAINAGE AREA WITH A MINIMUM

FINISH SLOPE OF 1/2-INCH PER FOOT AT GUTTER EDGES. CONSTRUCT

THE AREA USING TAPERED POLYISOCYANURATE INSULATION CUT TO

CREATE A FLUSH CONDITION AT THE EDGE NAILER(S) AND INSULATION.

4" FLANGE

1/2" HUG

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE WALL AT FLASHING PIECE INTERSECTIONS.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE

PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE

MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY

OF MOISTURE TO EXIT WALL SYSTEMS.

PREFINISHED 24 GA. GALV. STEEL REGLETED

COUNTERFLASHING. SECURE TO SUBSTRATE WITH

GASKETED FASTENERS 12-INCHES O.C., MIN. 2

FASTENERS.

SEALANT

CUT SIDING TO WALL

2" M

IN

1" M

IN

PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.

TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE

BEHIND TURN-UP, AND SECURE.

FULLY-ADHERED EPDM FLASHING MEMBRANE

COPING CAP TERMINATION

AT END WALLS

FOR USE WHERE PARAPET WALLS AND

RELATED COPING CAPS TERMINATE

INTO VERTICAL WALLS.

PREFINISHED 24 GA. GALV. STEEL REGLETED

COUNTERFLASHING. SECURE TO SUBSTRATE WITH

GASKETED FASTENERS 12-INCHES O.C., MIN. 2

FASTENERS.

SEALANT

CUT REGLET INTO WALL

2" M

IN

1" M

IN

PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.

TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE

BEHIND TURN-UP, AND SECURE.

FULLY-ADHERED EPDM FLASHING MEMBRANE

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

NOTE: MEMBRANE MUST BE EXTENDED TO CORNERS TO PROVIDE

COMPLETE COVERAGE OF THE WALL SURFACE.

COPING CAP JOINT PROFILE

SINGLE-LOCK STANDING SEAM; FOR USE WHERE

ADJACENT COPING CAPS ARE TO BE JOINED, BUTTON PUNCH.

22 GA. GALV. STEEL CONTINUOUS CLEAT. FABRICATE AS SHOWN TO

CREATE 1/2-INCH PER FOOT SLOPE TOWARD INNER FACE. SECURE

HORIZONTAL FLANGE AND VERTICAL FACE WITH RING SHANK COATED

NAILS 6-INCHES O.C. MAX.

EXTEND FULLY-ADHERED EPDM FLASHING MEMBRANE UP AND

OVER PARAPET WALL, AND DOWN OUTSIDE FASCIA. APPLY

SEALANT TO BACK SIDE OF FLASHING MEMBRANE, AND SECURE

12" O.C. MAX.

1"

SEALANT - SEAL BOTH ENDS OF

STANDING SEAM

PARAPET WALL STEEL COPING CAP

BUTTON PUNCH

3" M

IN

PREFINISHED 24 GA. GALV. STEEL COPING CAP.

HOOK OUTSIDE FACE TO CONTINUOUS CLEAT,

AND SECURE INNER FACE WITH GASKETED

FASTENERS APPROPRIATE FOR THE

SUBSTRATE ENCOUNTERED 18-INCHES O.C.

MAX., AND WITHIN 2-INCHES OF EACH END.

JOIN ADJACENT CAP SECTIONS USING 1-INCH

HIGH, SINGLE-LOCK STANDING SEAMS.

BUTTON PUNCH BOTH ENDS.

EXISTING STRUCTURAL DECK

SPECIFIED POLYISO. INSULATION

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO

EXISTING WALL WITH PROPER SUBSTRATE FASTENERS;

TWO ROWS 24-INCHES O.C., STAGGERED

H

EI

G H

T

VA

R

IE

S;

-IN

C

H M

IN

IM

U M

NOMINAL 2-INCH THICK WOOD BLOCKING - WIDTH AS NECESSARY

TO MATCH EXISTING PARAPET WALL WIDTH. THICKNESS AS

NECESSARY TO ACHIEVE 4-INCH MINIMUM FLASHING HEIGHT.

SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE

FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A

BUILDING CORNER.

4" M

IN

8" M

IN

2" M

IN

4" M

IN

M

AX

. H

EI

G H

T

PO

SS

IB

LE

1" M

IN

PREFINISHED 24 GA. GALV. STEEL SLIP

COUNTERFLASHING. SECURE TO EXISTING

COUNTERFLASHING AS SHOWN USING GASKETED

FASTENERS 12-INCHES O.C. MAX., AND WITHIN

2-INCHES OF EACH END.

EXISTING COUNTERFLASHING

EXISTING METAL WALL SIDING - DO NOT DISTURB.

ALTERNATE COUNTERFLASHING NO. 1

FOR USE BELOW EXISTING METAL WALL SIDING WHERE 8-INCH

MINIMUM FLASHING HEIGHT CAN BE ACHIEVED.

ALTERNATE COUNTERFLASHING NO. 2

FOR USE BELOW EXISTING METAL WALL SIDING WHERE 8-INCH

MINIMUM FLASHING HEIGHT CANNOT BE ACHIEVED.

PREFINISHED 24 GA. GALV. STEEL SLIP

COUNTERFLASHING. SECURE TO EXISTING

COUNTERFLASHING AS SHOWN USING GASKETED

FASTENERS 12-INCHES O.C. MAX., AND WITHIN

2-INCHES OF EACH END.

EXISTING COUNTERFLASHING - CUT AS SHOWN.

EXISTING METAL WALL SIDING - DO NOT DISTURB.

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER

THE REQUIREMENTS AND RECOMMENDATIONS OF THE

EPDM ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.

SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND

WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION

BAR INSTALLATION, INSTALL MANUFACTURERS

RECOMMENDED SEALANT BEHIND FLASHING WHERE

TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF

FLASHING AND TERMINATION BAR AFTER INSTALLATION.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS

FOR THE PRESENCE OF MASONRY WEEPS AND

OTHER WALL DRAINAGE MECHANISMS. DO NOT

COVER WEEPS, OR IMPEDE THE ABILITY OF

MOISTURE TO EXIT WALL SYSTEMS.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

APPROX.

1/2"

3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING

WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS

24-INCHES O.C., STAGGERED

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

APPROX.

1/2"

3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING

WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS

24-INCHES O.C., STAGGERED

SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND

WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION

BAR INSTALLATION, INSTALL MANUFACTURERS

RECOMMENDED SEALANT BEHIND FLASHING WHERE

TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF

FLASHING AND TERMINATION BAR AFTER INSTALLATION.

22 GA. GALV. STEEL CONTINUOUS CLEAT.

FABRICATE WITH A 2-INCH FLANGE. SECURE

FLANGE AND VERTICAL FACE WITH RING SHANK

COATED NAILS 12-INCHES O.C. MAX. DECREASE

FASTENER SPACING TO 6-INCHES O.C. WITHIN

10-FEET OF A BUILDING CORNER.

2" M

IN

. O

R T

O M

AT

C

H

EX

IS

TI

N G

E

LE

VA

TI

O N

W H

IC

H

EV

ER

IS

G

R

EA

TE

R

3/4"

5/8"

7- 1/

2" M

AX

. F

AC

E

3/4-INCH PLYWOOD MECHANICALLY

ATTACHED TO EXISTING WALL WITH PROPER

SUBSTRATE FASTENERS - TWO ROWS

24-INCHES O.C., STAGGERED

SPECIFIED POLYISOCYANURATE INSULATION

EXISTING STRUCTURAL DECK

EPDM ROOFING MEMBRANE

REINFORCED PERIMETER FASTENING

STRIP WITH FACTORY-LAMINATED SEAM

TAPE. PRIME EPDM MEMBRANE PRIOR TO

APPLICATION TO REINFORCED FASTENING

STRIP.

EPDM FLASHING MEMBRANE, FULLY

ADHERED TO CURB

FASTENERS AND 2-INCH PLATES,

12-INCHES O.C. MAX.

COVER BOARD - 1/2-INCH THICK

APPROX.

1/2"

NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN

24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE

REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM

ROOFING MEMBRANE MANUFACTURER.

NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING

THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING

MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE

BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.

NOTE: SECURE TOP EDGE OF FLASHING USING AN ALUMINUM

TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN

2-INCHES OF EACH END. PRIOR TO TERMINATION BAR

INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED

SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE

PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR

AFTER INSTALLATION.

NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND

COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE

PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE

MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY

OF MOISTURE TO EXIT WALL SYSTEMS.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

EXISTING STRUCTURAL DECK

SPECIFIED POLYISOCYANURATE INSULATION

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

4" FLANGE

1/2" HUG

PREFINISHED 24 GA. GALV. STEEL PERIMETER

EDGE FASCIA PIECE. FABRICATE WITH 1/2-INCH

HUG AT EDGE OF FLANGE AS SHOWN. SECURE

FLANGE WITH NAILS 3-INCHES O.C. MAX. IN TWO

STAGGERED ROWS. HOOK BOTTOM EDGE TO

CONTINUOUS CLEAT.

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES

AS SHOWN AFTER COMPLETION OF WORK.

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.

NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT

PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE

MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND

RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.

PERIMETER EDGE FLANGE CONFIGURATION

AND NAILING PATTERN DIAGRAM

SCALE: NONE

NOTE: THE PURPOSE OF THIS

DIAGRAM IS TO SHOW PERIMETER

EDGE FASCIA FLANGE FASTENING

PATTERNS AND NAILER

CONFIGURATION. THE ACTUAL

FASCIA CONFIGURATION, SIZE OF

NAILERS, AND NUMBER OF NAILERS

REQUIRED TO ACHIEVE THE

REQUIREMENTS SHOWN IN THE

DETAIL BELOW WILL VARY.

4"

1/2" HUG

3/

4" APPROX.

1/2"

EXISTING STRUCTURAL DECK

SPECIFIED POLYISOCYANURATE INSULATION

COVER BOARD - 1/2-INCH THICK

EPDM ROOFING MEMBRANE

EQ

U

AL

; 7

-1 /2

" M

AX

NOTE: EXTEND EPDM ROOFING MEMBRANE OVER AND DOWN

PERIMETER EDGE AS SHOWN. SECURE WITH ROOFING

NAILS AFFIXED WITH 1" DIAMETER METAL CAPS 12" O.C.

MAX.

NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR

CLARITY.

3" MIN.

6" MIN.

4" FLANGE

1/2" HUG1/2" MIN.

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES

AS SHOWN AFTER COMPLETION OF WORK.

PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.

NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT

PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE

MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND

RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.

REINFORCED PERIMETER FASTENING STRIP WITH

FACTORY-LAMINATED SEAM TAPE. PRIME EPDM

MEMBRANE PRIOR TO APPLICATION TO REINFORCED

FASTENING STRIP.

FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.

PREFINISHED 24 GA. GALV. STEEL FASCIA EXTENSION PIECE. SECURE TO SUBSTRATE 12-INCHES

O.C. MAX. WITH SPECIFIED FASTENER APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED.

DECREASE FASTENER SPACING TO 6-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.

HOOK TO CONTINUOUS CLEAT AS SHOWN.

22 GA. GALV. STEEL CONTINUOUS CLEAT. SECURE WITH SPECIFIED FASTENER APPROPRIATE FOR

THE SUBSTRATE ENCOUNTERED 6-INCHES O.C. MAX.

NOMINAL 6-INCH WOOD BLOCKING - THICKNESS AS NECESSARY TO MATCH MAXIMUM

ROOF AREA INSULATION AND COVER BOARD THICKNESS WITH A CONSISTENT FINAL

NAILER ELEVATION. SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE

FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.

22 GA. GALV. STEEL CONTINUOUS CLEAT. SECURE FLANGE AND VERTICAL FACE

WITH SPECIFIED FASTENER APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED

6-INCHES O.C. MAX.

PREFINISHED 24 GA. GALV. STEEL FASCIA PIECE. FABRICATE AS SHOWN. SECURE FLANGE

WITH NAILS 3-INCHES O.C. MAX. IN TWO STAGGERED ROWS (REFER TO DIAGRAM ABOVE).

HOOK TO…

This is the start of the file's text. The full file is on GovTribe.