Attachment E - Clippert Academy Drawings.pdf
PDF 2 MB Posted
- Solicitation number
- RFP DET 270000000151 2
- Issued by
- Wayne County, Detroit City, Michigan
About this file
This document is a Design Review Set of architectural drawings for a roof replacement project at Clippert Academy, a Detroit Public Schools facility located at 1981 McKinstry Street, Detroit, Michigan. The project encompasses roof replacement work in multiple sections (A, B, C, E, F, and G) and includes detailed specifications for materials, installation requirements, and flashing details prepared by Testing Engineers & Consultants. The drawings are produced at ARCH D size (24-inch by 36-inch) and consist of six sheets, including a cover sheet, general information sheet, roof plans for different building sections, and comprehensive detail sheets addressing roof penetrations, flashing conditions, and drainage systems. The project requires contractor verification of existing site conditions, including building dimensions, roof area dimensions, drainage component locations, and existing roof system composition prior to proposal submission. Contractors must account for asbestos laboratory analysis and abatement procedures if asbestos-containing materials are identified, and coordinate with the owner regarding removal and disposal of non-friable asbestos.
The roof replacement system specifications include complete removal of existing roof membranes and insulation down to the structural deck, with deck inspection and necessary repairs to be determined by the owner. For Roof Areas B, C, E, F, and G, the project requires installation of self-adhering underlayment membrane, two layers of 2½-inch polyisocyanurate insulation (5 inches total), ½-inch high-density polyiso cover board, and a fully-adhered nominal 60-mil EPDM roofing membrane system with acceptable manufacturers including Carlisle, Johns Manville, and Elevate (Firestone). Roof Area A requires a complete asphalt shingle roof system with underlayment and flashing accessories. The contractor must provide an alternate price for refastening existing structural decks and unit pricing for areas requiring refastening, and must include removal and replacement of wood decking in the base bid with unit costs for final adjustments. An alternate price for a 20-year "total system warranty" for the roof system is required. All work must comply with applicable federal, state, and local codes and regulations, and conflicts between specified products and codes must be reported immediately to the owner.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTION
ISSUE
SHEET TITLE
STAMP
SHEET 01 OF 06
COVER
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Design Review Set
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
Clippert Academy
1981 McKinstry Street Detroit, MI 48201
ABBREVIATIONS
NORTH
p02
DRAWING INDEX
DRAWING
NUMBER
DRAWING
NAME
A-001 COVER
A-101 ROOF PLAN
A-501 DETAILS
SYMBOLS
ROOF-TO-WALL FLASHING
DETAIL
SCALE: N.T.S.
TITLE SYMBOLS
SECTION/DETAIL TITLE
LOCATION SYMBOLS
SECTION/DETAIL CUT
A-100
Detail Number
Sheet where detail is located
Cut line
NORTH ARROW
REFERENCE PHOTOGRAPH NUMBER
NOTE
NOTE
BREAK SYMBOL
A-502 DETAILS
A-102 ROOF PLAN
CLIPPERT ACADEMY
Roof Replacement Sections A, B, C, E, F, and G
1981 McKinstry St, Detroit, MI 48209
ISSUE
TYPE
95% ISSUE
REVISION
TYPE
REVISION
DATE
ISSUE
DATE
9/22/2026
REV
9/22/2026-
9/22/2026-
9/22/2026-
9/22/2026-
A-002 GENERAL INFORMATION SHEET 9/22/2026-95% ISSUE
95% ISSUE
95% ISSUE
95% ISSUE
95% ISSUE
AutoCAD SHX Text ADA AMERICANS WITH AMERICANS WITH DISABILITIES ACT ALT ALTERNATE, ALTERNATE, ALTERNATIVE ALUM ALUMINUM ALUMINUM ARCH ARCHITECT, ARCHITECT, ARCHITECTURAL CJ CONTROL JOINT CONTROL JOINT CL CENTERLINE CENTERLINE CMU CONCRETE CONCRETE MASONRY UNIT COMP COMPOSITE COMPOSITE CONC CONCRETE CONCRETE CONST CONSTRUCTION CONSTRUCTION COORD COORDINATE COORDINATE DEG DEGREES DEGREES DIA DIAMETER DIAMETER DIM DIMENSION DIMENSION DIST DISTANCE DISTANCE DIV DIVISION DIVISION DN DOWN DOWN DWG DRAWING DRAWING EA EACH EACH EJ EXPANSION JOINT EXPANSION JOINT EL ELEVATION ELEVATION ENG ENGINEER ENGINEER EQ EQUAL EQUAL EQUIP EQUIPMENT EQUIPMENT EXT EXTERIOR EXTERIOR EXIST EXISTING EXISTING FD FLOOR DRAIN FLOOR DRAIN FDN FOUNDATION FOUNDATION FT FOOT, FEET FOOT, FEET FTG FOOTING FOOTING FM FACTORY FACTORY MUTUAL GA GAGE, GAUGE GAGE, GAUGE GALV GALVANIZED GALVANIZED GC GENERAL GENERAL CONTRACTOR GWB GYPSUM WALL GYPSUM WALL BOARD GYP GYPSUM GYPSUM HD HEAVY DUTY HEAVY DUTY HDW HARDWARE HARDWARE HORIZ HORIZONTAL HORIZONTAL HT HEIGHT HEIGHT HVAC HEATING/ HEATING/ VENTILATION/ AIR CONDITIONING IN INCH, INCHES INCH, INCHES INT INTERIOR INTERIOR INSUL INSULATION INSULATION LG LONG LONG LH LEFT HAND LEFT HAND LT LIGHT LIGHT LVL LAMINATED LAMINATED VENEER LUMBER MAX MAXIMUM MAXIMUM MECH MECHANICAL, MECHANICAL, MECHANICAL CONTRACTOR MED MEDIUM MEDIUM MFR MANUFACTURER MANUFACTURER MIN MINIMUM MINIMUM MISC MISCELLANEOUS MISCELLANEOUS MO MASONRY MASONRY OPENING MTL METALMETAL
AutoCAD SHX Text NEC NATIONAL NATIONAL ELECTRICAL CODE NIC NOT IN NOT IN CONTRACT NTS NOT TO NOT TO SCALE OA OVERALL OVERALL OC ON CENTER ON CENTER OH OVERHEAD OVERHEAD OPP OPPOSITE, OPPOSITE, OPPOSITE HAND PCF POUNDS PER POUNDS PER CUBIC FOOT PERF PERFORATED PERFORATED PL PLATE PLATE PNL PANEL PANEL PNT PAINT PAINT PSF POUNDS PER POUNDS PER SQUARE FOOT QTY QUANTITY QUANTITY REQD REQUIRED REQUIRED REV REVISED REVISED RH RIGHT HAND RIGHT HAND RO ROUGH OPENING ROUGH OPENING RTU ROOF-TOP UNIT ROOF-TOP UNIT SF SQUARE FEET SQUARE FEET SIM SIMILAR SIMILAR SPEC SPECIFICATION SPECIFICATION STD STANDARD STANDARD STRUCT STRUCTURAL STRUCTURAL T&G TONGUE AND TONGUE AND GROOVE T/ TOP, TOP OF TOP, TOP OF TBD TO BE TO BE DETERMINED THK THICK, THICK, THICKNESS TYP TYPICAL TYPICAL UL UNDERWRITERS UNDERWRITERS LABORATORIES UNO UNLESS UNLESS NOTED OTHERWISE VERT VERTICAL VERTICAL W/ WITH WITH W/O WITHOUT WITHOUT WD WOOD WOOD WP WATERPROOF, WATERPROOF, WATERPROOFING, WEATHERPROOF, WOOD PANEL WT WEIGHTWEIGHT
AutoCAD SHX Text TYPOGRAPHIC SYMBOLS @ AT AT # POUND(S), POUND(S), NUMBER % PERCENT PERCENT & AND AND " INCH(ES) INCH(ES) ' FOOT, FEET FOOT, FEET ±PLUS OR MINUS MINUS DIAMETER °DEGREES ANGLE ANGLE CENTER LINECENTER LINE
PROJECT LOCATION MAP
ROOF PLAN SYMBOL LEGEND:
ORD
INS
C
S SKYLIGHT CURB
CAPPED CURB
ROOF HATCH
ROOF CURB
SUPPORT CURBS
ROOF DRAIN
ROOF DRAIN WITH INSERT
OVERFLOW ROOF DRAIN
THROUGH-WALL SCUPPER
OVERFLOW ROOF SCUPPER
ORS
SANITARY VENT
TUBULAR PENETRATION
HOT STACK
PIPE CHASE BOX
PERIMETER OR CURBED EDGE
PARAPET WALL OR AREA DIVIDER
EXPANSION JOINT
GUTTER EDGE
PITCH PAN
ROOF-TO-WALL TRANSITION
AREA TRANSITION
SATELLITE DISH ON ROOF
W WALKPAD
WALKWAY
SUPPLY OR CONDENSATE LINE
LADDER
SLOPE DIRECTION
RIDGE LINE
DUCT WORK
R RAISED EQUIPMENT
DOWNSPOUT SPLASHBLOCKS
SUMP AREA
CHIMNEY DOWNSPOUT
THROUGH-FASCIA SCUPPER
SCUPPER WITH CONDUCTOR BOX DETAIL NUMBER CALLOUT
SHEET NUMBER CALLOUT
SCOPE OF REPLACEMENT (HATCH)
GENERAL NOTES:
1. DRAWINGS ARE PRODUCED AT ARCH D (24-INCH BY 36-INCH) SIZE.
PLEASE NOTE AND VERIFY THE SCALE INDICATED ON EACH DRAWING.
NOTE THAT ROOF PLANS AND OTHER PROJECT DRAWINGS PRODUCED
ON OTHER PAPER SIZES MAY NOT BE CORRECTLY SCALED.
2. ALL COMPONENTS SHOWN ON PROJECT DRAWINGS ARE NEW UNLESS
SPECIFICALLY INDICATED AS EXISTING.
3. IT IS THE RESPONSIBILITY OF THE CONTRACTOR TO VERIFY EXISTING
PROJECT SITE CONDITIONS. THESE CONDITIONS INCLUDE, BUT ARE NOT
LIMITED TO: BUILDING DIMENSIONS AND PROPOSED PROJECT STAGING
LOCATIONS, ROOF REPLACEMENT AREA DIMENSIONS, ROOF DRAINAGE
COMPONENT LOCATIONS, ROOF PENETRATION LOCATIONS, EXISTING
ROOF SYSTEM COMPONENT MAKE-UP AND THICKNESS, AND PROJECT
REPAIR QUANTITIES (IF APPLICABLE). THE CONTRACTOR SHALL VISIT
AND BECOME FAMILIAR WITH THE SITE AND BUILDING PRIOR TO
PROPOSAL SUBMISSION. INCLUDE THE COST OF ALL WORK DESCRIBED
IN THE BIDDING DOCUMENTS AND THAT IS REQUIRED OR REASONABLY
IMPLIED TO ACHIEVE THE DESIGN INTENT OF THE BIDDING DOCUMENTS.
NOTIFY THE ROOF CONSULTANT OF ANY CONFLICTS BETWEEN EXISTING
CONDITIONS AND THE NEW WORK, OF ANY OMISSIONS OR CONFLICTS IN
THE DRAWINGS AND ANY RESTRICTIONS RELATED TO THE EXECUTION
OF THE WORK INCLUDING THE COORDINATION WITH OTHER TRADES.
4. PRODUCTS PROPOSED FOR USE AND PROJECT WORK SHALL BE IN
ACCORDANCE WITH APPLICABLE FEDERAL, STATE AND LOCAL
GOVERNING ORDINANCES, CODES AND REGULATIONS. NOTIFY THE
OWNER IMMEDIATELY OF CONFLICTS BETWEEN THE SPECIFIED
PRODUCTS AND/OR PROJECT WORK REQUIREMENTS AND CODES,
ORDINANCES AND/OR REGULATIONS.
5. IF DISCREPANCIES ARE DISCOVERED WITHIN THE PROJECT MANUAL OR
DRAWINGS; THE OWNER, NOT THE CONTRACTOR, SHALL DETERMINE
THE INTENT OF THE DESIGN AND PROVIDE CLARIFICATION. NO
ALLOWANCE SHALL BE MADE FOR CONTRACTOR MISINTERPRETATION
OR IMPLIED MISINTERPRETATION OF THE PROJECT MANUAL AND
DRAWINGS.
6. REFER TO THE PROJECT MANUAL AND ROOFING SYSTEM
MANUFACTURER WRITTEN INSTRUCTIONS FOR FURTHER CLARIFICATION
OF PROJECT REQUIREMENTS. NOTIFY THE OWNER IMMEDIATELY OF
CONFLICTS BETWEEN THE SPECIFIED DESIGN REQUIREMENTS AND THE
WRITTEN REQUIREMENTS AND RECOMMENDATIONS OF THE ROOFING
SYSTEM MANUFACTURER.
7. CLOSE AND SEAL ABANDONED OPENINGS TO MATCH EXISTING
ADJACENT SURFACES WHERE MECHANICAL, PLUMBING, AND/OR
8. CONTRACTOR SHALL TAKE NORMAL PRECAUTIONS SO THAT DEBRIS,
ROOFING MATERIAL, ETC., DOES NOT FALL INTO THE BUILDING OR ON
EQUIPMENT PER SECTIONS 014000 AND 015000.
SUMMARY OF ROOF REPLACEMENT WORK - AREAS A, B & C
A. ASBESTOS LABORATORY ANALYSIS REPORT: REFER TO SECTION 022623 FOR
INFORMATION RELATING TO THE LOCATION OF ACM, IF APPLICABLE, WITHIN PROJECT
AREAS. IF POSITIVE, REFER TO SECTIONS 013543 AND 028233 FOR PROCEDURES AND
REQUIREMENTS RELATED TO THE REMOVAL AND DISPOSAL OF NON-FRIABLE
ASBESTOS RELATED TO THIS PROJECT.
B. ROOF REMOVAL AND SUBSTRATE PREPARATION: REMOVE EXISTING ROOF SYSTEM
DOWN TO THE STRUCTURAL DECK, INCLUDING ROOF MEMBRANE(S), AND UNDERLYING
INSULATION, UNDERLAYMENTS, AND ADDITIONAL ROOF MEMBRANES. INSPECT THE
EXISTING STRUCTURAL DECK, AND INFORM THE OWNER IMMEDIATELY OF OBSERVED
DAMAGE AND OR DETERIORATION. TEMPORARILY DISPLACE ROOFTOP EQUIPMENT AS
NECESSARY TO COMPLETE THE SPECIFIED WORK. REFER TO SECTION 024102.
C. PROVIDE AN ALTERNATE PRICE FOR COMPLETE REFASTENING OF EXISTING
STRUCTURAL DECKS; PROVIDE A UNIT PRICE FOR AREAS OF EXISTING STRUCTURAL
DECK THAT REQUIRE REFASTENING. NOTE THAT REFASTENING OF PERIMETER WOOD
BLOCKING IS REQUIRED. REFER TO SECTION 061516 FOR RE-FASTENING
REQUIREMENTS.
D. AFTER ROOF REMOVAL AND INSPECTION OF THE EXISTING STRUCTURAL DECK AND
PERIMETER WOOD BLOCKING, PERFORM REPAIRS TO THE STRUCTURAL DECK, AS
DETERMINED NECESSARY BY THE OWNER. REFER TO SECTION 061516. REPLACE
DAMAGED OR DETERIORATED WOOD BLOCKING, AS DETERMINED NECESSARY BY THE
OWNER. REFER TO SECTION 061053.
E. PROVIDE REQUIRED WOOD BLOCKING WHERE INDICATED ON THE PROJECT
DRAWINGS. REFER TO SECTION 061053.
F. ROOF AREAS B,C,E,F&G: PROVIDE AN UNDERLAYMENT CONSISTING OF A SELF-ADHERING
MEMBRANE. PRIOR TO APPLICATION, PREPARE AND PRIME THE DECK AS REQUIRED
BY THE ROOFING MEMBRANE MANUFACTURER. REFER TO SECTION 072215.
G. ROOF AREAS B,C,E,F&G: PROVIDE TWO LAYERS OF 2-1/2 INCH POLYISOCYANURATE INSUL
(5-INCHES TOTAL). IF INDICATED ON THE PROJECT DRAWINGS, PROVIDE INSULATION
SADDLES AND CRICKETS WHERE SHOWN. REFER TO SECTION 072221 FOR ADDITIONAL
INSULATION PRODUCT AND INSTALLATION REQUIREMENTS.
H. PROVIDE A 1/2-INCH HIGH DENSITY POLYISO COVER BOARD OVER THE UNDERLYING
INSULATION. REFER TO SECTIONS 072221 FOR ADDITIONAL PRODUCT AND
INSTALLATION REQUIREMENTS.
I. ROOF AREA A: PROVIDE A COMPLETE ASPHALT SHINGLE ROOF SYSTEM;
INCLUDING UNDERLAYMENT, SELF-ADHERING MEMBRANE (WHERE APPLICABLE),
ASPHALT SHINGLES, AND BITUMINOUS AND SHEET METAL FLASHING ACCESSORIES.
REFER TO SECTION 073113 FOR PRODUCT AND INSTALLATION REQUIREMENTS.
J. ROOF AREAS B,C,E,F&G: PROVIDE A FULLY-ADHERED, NOMINAL 60-MIL EPDM ROOF SYSTEM.
AFTER INSTALLATION OF SPECIFIED INSULATION AND COVER BOARD, INSTALL THE
EPDM ROOFING MEMBRANE IN BONDING ADHESIVE. PROVIDE EPDM AND SHEET METAL
FLASHINGS AS SPECIFIED. PROVIDE AN ALTERNATE PRICE FOR A 20-YEAR, “TOTAL
SYSTEM WARRANTY” FOR THE ROOF SYSTEM. REFER TO SECTIONS 075323 AND 076205
FOR PRODUCT AND INSTALLATION REQUIREMENTS.
1. ACCEPTABLE MANUFACTURERS:
a. CARLISLE
b. JOHNS MANVILLE
c. ELEVATE (FIRESTONE)
K. PROVIDE SEALANTS AT LOCATIONS INDICATED ON THE PROJECT DRAWINGS. REFER
TO SECTION 079201.
L. THE CONTRACTOR SHALL INCLUDE IN THEIR BASE BID REMOVAL AND REPLACEMENT
OF WOOD DECKING. UNIT COSTS WILL BE USED TO ADJUST
FINAL AMOUNT.
INDEX OF DRAWINGS:
SHEET 01 OF 06
SHEET 02 OF 06
SHEET 03 OF 06
SHEET 05 OF 06
SHEET 06 OF 06
TITLE SHEET
GENERAL INFORMATION SHEET 01 OF 01
ROOF PLAN - AREAS A, B, C & E
ROOF PLAN DETAILS 01-09
ROOF PLAN DETAILS 10-14
XX
X
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTION
ISSUE
SHEET TITLE
STAMP
SHEET 02 OF 06
GENERAL NOTES
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Design Review Set
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
Clippert Academy
1981 McKinstry Street Detroit, MI 48201
SHEET 04 OF 06 ROOF PLAN - AREAS F & G
A-501
A-501
A-501
A-501
A-502
A-502
A-501
A-502
A-501
A-501
A-502
A-502
A-502
A-501
A-502
A-502
A-502
A-502
A-502
A-502
A-502
A-502
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTION
ISSUE
SHEET TITLE
STAMP
SHEET 03 OF 06
ROOF PLAN
SECTIONS
A, B, C & E
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Design Review Set
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
Clippert Academy
1981 McKinstry Street Detroit, MI 48201
CLIPPERT MULTICULTURAL MAGNET HONORS ACADEMY
KEY ROOF PLAN
SCALE: N.T.S.
A A-101
NORTH
GENERAL NOTES
SECTIONS A, B, C, AND E
ROOF PLAN
SCALE: 1/16" = 1'-0"
A-101
1. ALL DIMENSIONS ARE APPROXIMATE.
2. MINIMUM 8" HIGH CURB FOR ALL ITEMS.
NIC
NIC
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
A
A-501
2 TYP.
A-501
2 TYP.
A-501
A-502
A-502
A-501
A-501
A-501
A-501
A-501
A-501
A-502 10A-502
A-501
A-501
A-501
A-501
A-501
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTION
ISSUE
SHEET TITLE
STAMP
SHEET 04 OF 06
ROOF PLAN
SECTIONS F & G
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Design Review Set
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
Clippert Academy
1981 McKinstry Street Detroit, MI 48201
CLIPPERT MULTICULTURAL MAGNET HONORS ACADEMY
KEY ROOF PLAN
SCALE: N.T.S.
A A-101
NORTH
GENERAL NOTES
1. ALL DIMENSIONS ARE APPROXIMATE.
2. MINIMUM 8" HIGH CURB FOR ALL ITEMS.
SECTIONS F, G, H AND I
ROOF PLAN
SCALE: 1/16" = 1'-0"
A-102
NIC
NIC
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text A
AutoCAD SHX Text H
AutoCAD SHX Text I
AutoCAD SHX Text F
AutoCAD SHX Text G
AutoCAD SHX Text B
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
A
4" MIN.
7" MIN.
4" MIN.
24" MINIMUM
8" M
IN
IM
U M
F
LA
SH
IN
G H
EI
G
H T
PREFINISHED 24 GA. GALV. STEEL SLIP COUNTERFLASHING.
SECURE TO EXISTING COUNTERFLASHING AS SHOWN USING
FASTENERS APPROPRIATE FOR THE SUBSTRATE
ENCOUNTERED. SECURE COUNTERFLASHING 12-INCHES
O.C. MAX., AND WITHIN 2-INCHES OF EACH END.
SELF-ADHEREING MEMBRANE. APPLY AS COUNTERFLASHING
FLANGE STRIPPING. EXTEND 4" MINIMUM UPSLOPE ABOVE
FLANGE AS SHOWN.
EXISTING UNDERLAYMENT. LAP OVER SELF-ADHERING
UNDERLAYMENT AS SHOWN. PROVIDE NEW
UNDERLAYMENT, IF NECESSARY, TO ACHIEVE CONDITION
SHOWN.
NOTE: SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND
WITHIN 2-INCHES OF EACH END. PRIOR TO TERMINATION
BAR INSTALLATION, INSTALL MANUFACTURERS
RECOMMENDED SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL TOP EDGE OF
FLASHING AND TERMINATION BAR AFTER INSTALLATION.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR
THE PRESENCE OF MASONRY WEEPS AND OTHER
WALL DRAINAGE MECHANISMS. DO NOT COVER
WEEPS, OR IMPEDE THE ABILITY OF MOISTURE TO
EXIT WALL SYSTEMS.
NEW ASPHALT SHINGLES. REMOVE ALL COURSES OF SHINGLES TO
ALLOW FOR INSTALLATION OF NEW ROOF SYSTEM FLASHING AND
COUNTERFLASHING O A WATERTIGHT CONDITION. INSTALL NEW
ASPHALT SHINGLES, TO REPLACE ASPHALT SHINGLES REMOVED
DURING WORK. REPLACEMENT ASPHALT SHINGLES TO MATCH
COLOR, TYPE AND SIZE OF EXISTING.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
EPDM FLASHING MEMBRANE, FULLY-ADHERED TO WALL.
REFER TO NOTE REGARDING SECUREMENT OF FLASHING.
COVER BOARD - 1/2-INCH THICK
MEMBRANE SECUREMENT ALTERNATE NO. 1
3/4"
5/8"
3/4-INCH PLYWOOD MECHANICALLY
ATTACHED TO EXISTING WALL WITH PROPER
SUBSTRATE FASTENERS - TWO ROWS
24-INCHES O.C., STAGGERED
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
APPROX.
1/2"
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE
REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM
ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
NOTE: SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO TERMINATION BAR
INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE
PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR
AFTER INSTALLATION.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
4"
1/2" HUG
3/ 4"
EQ
U
AL
; 7
-1 /2
" M
AX
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH.
SEAL EDGES AS SHOWN AFTER COMPLETION OF WORK.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.
NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT
PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE
MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND
RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.
APPROX.
1/2"
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
PREFINISHED 24 GA. GALV. STEEL FASCIA PIECE. FABRICATE AS SHOWN. SECURE FLANGE
WITH NAILS 3-INCHES O.C. MAX. IN TWO STAGGERED ROWS (REFER TO DIAGRAM ABOVE).
HOOK TO CONTINUOUS CLEAT AS SHOWN.
NOMINAL 6-INCH WOOD BLOCKING - THICKNESS AS NECESSARY TO MATCH MAXIMUM
ROOF AREA INSULATION AND COVER BOARD THICKNESS WITH A CONSISTENT FINAL
NAILER ELEVATION. SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.
22 GA. GALV. STEEL CONTINUOUS CLEAT. SECURE FLANGE AND VERTICAL FACE
WITH RING SHANK COATED NAILS 12-INCHES O.C. MAX. DECREASE FASTENER
SPACING TO 6-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.
2" M
IN
. O
R T
O M
AT
C
H
EX
IS
TI
N G
E
LE
VA
TI
O N
W H
IC
H
EV
ER
IS
G
R
EA
TE
R
3/4"
5/8"
7- 1/
2" M
AX
. F
AC
E
APPROX.
1/2"
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE
REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM
ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
NOTE: SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO TERMINATION BAR
INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE
PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR
AFTER INSTALLATION.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
22 GA. GALV. STEEL CONTINUOUS CLEAT.
FABRICATE WITH A 2-INCH FLANGE. SECURE
FLANGE AND VERTICAL FACE WITH RING SHANK
COATED NAILS 12-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 6-INCHES O.C. WITHIN
10-FEET OF A BUILDING CORNER.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - MIN. 1/2-INCH THICK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP
WITH FACTORY-LAMINATED SEAM TAPE.
PRIME MEMBRANE PRIOR TO APPLICATION
TO REINFORCED FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES
O.C. MAX.
EPDM FLASHING MEMBRANE, FULLY-ADHERED
TO WALL REFER TO NOTE REGARDING
SECUREMENT OF FLASHING.
PREFINISHED 24 GA. GALV. STEEL PERIMETER
EDGE FASCIA PIECE. FABRICATE WITH 1/2-INCH
HUG AT EDGE OF FLANGE AS SHOWN. SECURE
FLANGE WITH NAILS 3-INCHES O.C. MAX. IN TWO
STAGGERED ROWS. HOOK BOTTOM EDGE TO
CONTINUOUS CLEAT.
3/4-INCH PLYWOOD MECHANICALLY
ATTACHED TO EXISTING WALL WITH
PROPER SUBSTRATE FASTENERS - TWO
ROWS 24-INCHES O.C., STAGGERED
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES
AS SHOWN AFTER COMPLETION OF WORK.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.
NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT
PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE
MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND
RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.
TAPERED POLYISOCYANURATE INSULATION. CUT TO MATCH
CONDITION SHOWN.
CREATE A 3-FOOT ENHANCED DRAINAGE AREA WITH A MINIMUM
FINISH SLOPE OF 1/2-INCH PER FOOT AT GUTTER EDGES. CONSTRUCT
THE AREA USING TAPERED POLYISOCYANURATE INSULATION CUT TO
CREATE A FLUSH CONDITION AT THE EDGE NAILER(S) AND INSULATION.
4" FLANGE
1/2" HUG
UNDERLAYMENT
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
SPECIFIED UNDERLAYMENT
4" M
IN
8" M
IN
3"
APPROX.
1/2"
SHEET METAL WALL
SIDING WIDTH PLUS 1/2"
1- 1/
2"
3"
5/8" 3/4"
PREFINISHED 24 GA. GALV. STEEL SLIP
COUNTERFLASHING. SECURE TO
SUBSTRATE USING GASKETED FASTENERS
12-INCHES O.C. MAX., AND WITHIN 2-INCHES
OF EACH END.
PREFINISHED 24 GA. GALV. STEEL
COUNTERFLASHING RECEIVER. SECURE
TO SUBSTRATE 12-INCHES O.C.
EXISTING SHEET METAL WALL SIDING
EXISTING WALL
ENLARGED RECEIVER
DETAIL
SCALE: NONE
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO WALL
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
UNDERLAYMENT
PREFINISHED 24 GA. GALV. STEEL SLIP
COUNTERFLASHING. SECURE TO SUBSTRATE
USING GASKETED FASTENERS 12-INCHES O.C. MAX.,
AND WITHIN 2-INCHES OF EACH END.
PREFINISHED 24 GA. GALV. STEEL COUNTERFLASHING
RECEIVER. SECURE TO SUBSTRATE 12-INCHES O.C. REFER
TO ENLARGED DETAIL FOR FURTHER CLARIFICATION.
EXISTING SHEET METAL WALL SIDING
EXISTING WALL
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER THE
REQUIREMENTS AND RECOMMENDATIONS OF THE EPDM
ROOFING MEMBRANE MANUFACTURER.
SECURE TOP EDGE OF FLASHING USING AN ALUMINUM
TERMINATION BAR SECURED 12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO TERMINATION BAR
INSTALLATION, INSTALL MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE TERMINATION BAR WILL BE
PLACED. SEAL TOP EDGE OF FLASHING AND TERMINATION BAR
AFTER INSTALLATION.
6"
3/4
5/8
APPROX.
1/2"
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
COPING CAP TERMINATION
AT END WALLS
FOR USE WHERE PARAPET WALLS AND
RELATED COPING CAPS TERMINATE
INTO VERTICAL WALLS.
PREFINISHED 24 GA. GALV. STEEL REGLETED
COUNTERFLASHING. SECURE TO SUBSTRATE WITH
GASKETED FASTENERS 12-INCHES O.C., MIN. 2
FASTENERS.
SEALANT
CUT SIDING TO WALL
2" M
IN
1" M
IN
PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.
TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE
BEHIND TURN-UP, AND SECURE.
FULLY-ADHERED EPDM FLASHING MEMBRANE
COPING CAP TERMINATION
AT END WALLS
FOR USE WHERE PARAPET WALLS AND
RELATED COPING CAPS TERMINATE
INTO VERTICAL WALLS.
PREFINISHED 24 GA. GALV. STEEL REGLETED
COUNTERFLASHING. SECURE TO SUBSTRATE WITH
GASKETED FASTENERS 12-INCHES O.C., MIN. 2
FASTENERS.
SEALANT
CUT REGLET INTO WALL
2" M
IN
1" M
IN
PREFINISHED 24 GA. GALV. STEEL PARAPET CAP.
TURN UP WALL 2-INCHES, MIN., INSTALL BUTYL TAPE
BEHIND TURN-UP, AND SECURE.
FULLY-ADHERED EPDM FLASHING MEMBRANE
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
PREFINISHED 24 GA. GALV. STEEL COPING CAP.
HOOK OUTSIDE FACE TO CONTINUOUS CLEAT,
AND SECURE INNER FACE WITH GASKETED
FASTENERS APPROPRIATE FOR THE SUBSTRATE
ENCOUNTERED 18-INCHES O.C. MAX., AND WITHIN
2-INCHES OF EACH END. JOIN ADJACENT CAP
SECTIONS USING 1-INCH HIGH STANDING SEAMS.
22 GA. GALV. STEEL CONTINUOUS CLEAT.
FABRICATE AS SHOWN TO CREATE 1/2-INCH PER
FOOT SLOPE TOWARD INNER FACE. SECURE
HORIZONTAL FLANGE AND VERTICAL FACE WITH
RING SHANK COATED NAILS 6-INCHES O.C. MAX.
NOTE: EXTEND EPDM ROOFING MEMBRANE OVER AND DOWN
PERIMETER EDGE AS SHOWN. APPLY SEALANT TO BACK
SIDE OF MEMBRANE AND SECURE WITH ROOFING NAILS
AFFIXED WITH 1" DIAMETER METAL CAPS 12" O.C. MAX.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
NOMINAL 2-INCH THICK WOOD BLOCKING - WIDTH AS NECESSARY
TO MATCH EXISTING PARAPET WALL WIDTH. THICKNESS AS
NECESSARY TO ACHIEVE 4-INCH MINIMUM FLASHING HEIGHT.
SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A
BUILDING CORNER.
H
EI
G H
T
VA
R
IE
S;
-IN
C
H M
IN
IM
U M
3" M
IN
CL
1/2"@
NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK
AREA USING SOLVENTS AND WIRE BRUSH; REMOVING DIRT,
OIL, GREASE, AND OTHER CONTAMINANTS FROM THE
WORK AREA. TIN THE WORK AREA BY APPLYING ACID
(FLUX). PERFORM SOLDERING WORK. AFTER COMPLETION
OF WORK, REMOVE EXCESS ACID (FLUX) FROM THE WORK
AREA.
NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL
RECEIVE PRESSURE SENSITIVE OUTER SEAM
FLASHING PRIOR TO APPLICATION..
4" MIN.
4" M
IN
2" MIN. ALL SIDES
SEALANT - TYP
STAINLESS STEEL
CLAMPING BAND
POURABLE SEALER - SLOPE TO ALLOW FOR PROPER DRAINAGE.
NON-SHRINK GROUT - FILL TO 2" BELOW RIM OF PITCH PAN.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
PRESSURE-SENSITIVE FLASHING - WIDTH AS NECESSARY TO RESULT
IN CONDITION SHOWN.
NOMINAL 6-INCH WOOD BLOCKING AS NECESSARY TO MATCH COVER
BOARD AND INSULATION THICKNESS. SECURE TO SUBSTRATE
18-INCHES O.C. MAX., AND WITHIN 2-INCHES OF EACH END.
24 GA. STAINLESS STEEL PITCH PAN WITH 6-INCH FLANGE AND ROUNDED
CORNERS. SOLDER ALL SEAMS AND LAPS WATERTIGHT - REFER TO NOTE
REGARDING SOLDERING.
EXISTING PENETRATION
24 GA. STAINLESS STEEL STORM COLLAR. SOLDER ALL LAPS AND SEAMS
WATERTIGHT. REFER TO NOTE REGARDING SOLDERING. INSTALL BUTYL
TAPE BEHIND COLLAR AS SHOWN PRIOR TO INSTALLATION OF CLAMP.
SEAL TOP OF HOOD AS SHOWN.
UNDERLAYMENT
FIELD VERIFY WALL WIDTH
3" M
IN
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS FOLLOWING
THE RECOMMENDATIONS AND REQUIREMENTS OF THE ROOFING
MEMBRANE MANUFACTURER. PROVIDE "T-JOINT COVERS" AT THE
BASE OF THE CURB AT FLASHING PIECE INTERSECTIONS.
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR THE
PRESENCE OF MASONRY WEEPS AND OTHER WALL DRAINAGE
MECHANISMS. DO NOT COVER WEEPS, OR IMPEDE THE ABILITY
OF MOISTURE TO EXIT WALL SYSTEMS.
" M
AX
NOTE: PROVIDE PREFINISHED 24 GA. GALV. STEEL FASCIA
EXTENSION AND 22 GA. CONTINUOUS CLEAT AS SHOWN TO
MATCH EXISTING SHEET METAL CONFIGURATION AND
ELEVATION.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING
STRIP WITH FACTORY-LAMINATED SEAM
TAPE. PRIME EPDM MEMBRANE PRIOR TO
APPLICATION TO REINFORCED FASTENING
STRIP.
EPDM FLASHING MEMBRANE, FULLY
ADHERED TO CURB
FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
COVER BOARD - 1/2-INCH THICK
APPROX.
1/2"
3/4-INCH PLYWOOD MECHANICALLY ATTACHED TO EXISTING
WALL WITH PROPER SUBSTRATE FASTENERS - TWO ROWS
24-INCHES O.C., STAGGERED
PREFINISHED 24 GA. GALV. STEEL COPING CAP. HOOK OUTER
AND INNER FACES TO CONTINUOUS CLEATS AS SHOWN. JOIN
ADJACENT CAP SECTIONS USING 1-INCH HIGH STANDING
SEAMS.
22 GA. GALV. STEEL CONTINUOUS CLEAT. FABRICATE AS SHOWN TO
CREATE 1/2-INCH PER FOOT SLOPE TOWARD INNER FACE. SECURE
HORIZONTAL FLANGE AND VERTICAL FACE WITH RING SHANK COATED
NAILS 6-INCHES O.C. MAX.
EXTEND FULLY-ADHERED EPDM FLASHING MEMBRANE UP AND
OVER PARAPET WALL, AND DOWN OUTSIDE FASCIA. APPLY
SEALANT TO BACK SIDE OF FLASHING MEMBRANE, AND SECURE
12" O.C. MAX.
H
EI
G H
T
VA
R
IE
S;
-IN
C
H M
IN
IM
U M
NOMINAL 2-INCH THICK WOOD BLOCKING - WIDTH AS NECESSARY
TO MATCH EXISTING PARAPET WALL WIDTH. THICKNESS AS
NECESSARY TO ACHIEVE 4-INCH MINIMUM FLASHING HEIGHT.
SECURE TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 9-INCHES O.C. WITHIN 10-FEET OF A
BUILDING CORNER.
EXISTING ASPHALT SHINGLES. REMOVE COURSES OF SHINGLES AS
NECESSARY TO ALLOW FOR INSTALLATION OF NEW ROOF SYSTEM
FLASHING AND COUNTERFLASHING WATERTIGHT CONDITION.
INSTALL NEW ASPHALT SHINGLES, TO REPLACE ASPHALT SHINGLES
REMOVED DURING WORK. REPLACEMENT ASPHALT SHINGLES TO
MATCH COLOR, TYPE AND SIZE OF EXISTING.
LCC
PLAN VIEW OF ROOF SUMP AREA
SCALE: NONE
TAPERED INSULATION/EDGE STRIPS AS NEEDED
TO RESULT IN 8'-0" X 8'-0" SUMP AREA
ROOF DRAIN
NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING
RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE
CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN
FLASHING COMPONENTS.
CUT DRAINAGE HOLE IN MEMBRANE MIN. 1/2" GREATER
THAN DRAIN PIPE DIAM. ON ALL SIDES
EXTEND MEMBRANE 1" MIN.
BEYOND CLAMPING RING
IN
ST
AL
L
TA
PE
R
ED
P O
LY
IS
O C
YA
N
U R
AT
E
IN
SU
LA
TI
O N
A N
D /O
R T
AP
ER
ED
E
D G
E
ST
R
IP
T O
R
ES
U
LT
IN
' x
' S U
M P
AR
EA
(T
YP
APPROX. 4'-0" - REFER TO NOTE ABOVE REGARDING ROOF SUMP AREA
CONSTRUCTION AND SLOPE REQUIREMENTS
IN
ST
AL
L
TA
PE
R
ED
P O
LY
IS
O C
YA
N
U R
AT
E
IN
SU
LA
TI
O N
A N
D /O
R T
AP
ER
ED
E
D G
E
ST
R
IP
T O
R
ES
U
LT
IN
' x
' S U
M P
AR
EA
(T
YP
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
TAPERED POLYISOCYANURATE INSULATION, AND/OR
TAPERED EDGE STRIP(S) AS NECESSARY TO RESULT IN A
8-FOOT BY 8-FOOT MINIMUM TAPERED ROOF DRAIN SUMP
AREA WITH A MINIMUM SLOPE OF 1/4-INCH PER FOOT.
EXISTING ROOF DRAIN ASSEMBLY. CLEAN BOWL FREE OF ALL
EXISTING FLASHING MATERIALS AND BITUMINOUS RESIDUE PRIOR
TO INSTALLATION OF EPDM ROOFING MEMBRANE AND
MANUFACTURER'S RECOMMENDED SEALANT. INSPECT DRAIN
BOWL, CLAMPING RING, AND OTHER ASSEMBLY COMPONENTS FOR
DAMAGE. REPLACE DAMAGED COMPONENTS AS NECESSARY PER
SECTION 024100.
EXISTING ROOF DRAIN STRAINER. REMOVE AND DISCARD
DAMAGED, BROKEN OR PLASTIC-TYPE STRAINER(S).
REPLACE DISCARDED STRAINERS WITH CAST IRON
STRAINERS. REFER TO SECTION 024100.
NOTE: EXTEND EPDM ROOFING MEMBRANE UNDER CLAMPING
RING AND INTO THE ROOF DRAIN. TIGHTLY SECURE
CLAMPING RING AFTER INSTALLATION OF ROOF DRAIN
FLASHING COMPONENTS.
MANUFACTURER'S RECOMMENDED SEALANT. INSTALL ONE TUBE,
MINIMUM, UNDER EPDM ROOFING MEMBRANE AT CLAMPING RING,
CONTINUOUS BEAD - TO ROOF DRAIN ASSEMBLY INTERSECTION.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
NOTE: IF FIELD SEAM EDGE IS WITHIN 9" OF DRAIN COMPRESSION
RING, EPDM TARGET PATCH REQUIRED.
UNDERLAYMENT
7-1/2" MAX. FACE
4" FLANGE
1/2" HUG
NOTE: PRIOR TO INSTALLATION OF NEW FLASHING AND
COUNTERFLASHING, INSPECT EXISTING WALLS FOR
THE PRESENCE OF MASONRY WEEPS AND OTHER
WALL DRAINAGE MECHANISMS. DO NOT COVER
WEEPS, OR IMPEDE THE ABILITY OF MOISTURE TO
EXIT WALL SYSTEMS.
22 GA. GALV. STEEL CONTINUOUS CLEAT.
FABRICATE WITH A 2-INCH FLANGE. SECURE
FLANGE AND VERTICAL FACE WITH RING SHANK
COATED NAILS 12-INCHES O.C. MAX. DECREASE
FASTENER SPACING TO 6-INCHES O.C. WITHIN
10-FEET OF A BUILDING CORNER.
PREFINISHED 24 GA. GALV. STEEL PERIMETER
EDGE FASCIA PIECE. FABRICATE WITH 1/2-INCH
HUG AT EDGE OF FLANGE AS SHOWN. SECURE
FLANGE WITH NAILS 3-INCHES O.C. MAX. IN TWO
STAGGERED ROWS. HOOK BOTTOM EDGE TO
CONTINUOUS CLEAT.
3/4"
5/8"
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 9-INCH WIDTH. SEAL EDGES
AS SHOWN AFTER COMPLETION OF WORK.
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR 6-INCH WIDTH.
NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE REINFORCEMENT
PIECE AT SHEET METAL FASCIA JOINTS. REFER TO ROOFING MEMBRANE
MANUFACTURER REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND
RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.
TAPERED POLYISOCYANURATE INSULATION. CUT TO MATCH
CONDITION SHOWN.
CREATE A 3-FOOT ENHANCED DRAINAGE AREA WITH A MINIMUM
FINISH SLOPE OF 1/2-INCH PER FOOT AT GUTTER EDGES. CONSTRUCT
THE AREA USING TAPERED POLYISOCYANURATE INSULATION CUT TO
CREATE A FLUSH CONDITION AT THE EDGE NAILER(S) AND INSULATION. EXISTING UNDERLAYMENT. LAP OVER SELF-ADHERING
UNDERLAYMENT AS SHOWN. PROVIDE NEW UNDERLAYMENT
TO ACHIEVE CONDITION SHOWN.
NEW ASPHALT SHINGLES. REMOVE ALL COURSES OF SHINGLES TO
ALLOW FOR INSTALLATION OF NEW ROOF SYSTEM FLASHING AND
COUNTERFLASHING WATERTIGHT CONDITION. INSTALL NEW
ASPHALT SHINGLES, TO REPLACE ASPHALT SHINGLES REMOVED
DURING WORK. REPLACEMENT ASPHALT SHINGLES TO MATCH
COLOR, TYPE AND SIZE OF EXISTING.
CLIENT
PROFESSIONAL
PROJECT
DESCRIPTION
ISSUE
SHEET TITLE
STAMP
SHEET 05 OF 06
ROOF PLAN
DETAILS 1-9
Testing Engineers & Consultants
1343 Rochester Road Troy, MI 48083
Design Review Set
Detroit Public Schools
3011 W. Grand Blvd Detroit, MI 48202
Clippert Academy
1981 McKinstry Street Detroit, MI 48201
DETAIL 1 -
SCALE: NONE
PITCH PAN FLASHING DETAIL 2 -
SCALE: NONE
ROOF DRAIN FLASHING DETAIL 3 -
SCALE: NONE
PARAPET WALL FLASHING
DETAIL 4 -
SCALE: NONE
FLASHING AT METAL WALL PANELS DETAIL 5 -
SCALE: NONE
ROOF TRANSITION FLASHING DETAIL 6 -
SCALE: NONE
ROOF TRANSITION FLASHING
DETAIL 7 -
SCALE: NONE
ROOF TRANSITION FLASHING DETAIL 8 -
SCALE: NONE
ROOF TRANSITION FLASHING DETAIL 9 -
SCALE: NONE
PARAPET WALL FLASHING
AutoCAD SHX Text
AutoCAD SHX Text Copyright 1997,1998,1999 United States Postal Service c
8" M
IN
IM
U M
H
EI
G H
T
NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS OF ELECTRICAL,
PLUMBING OR MECHANICAL COMPONENTS RELATED TO
THE DISPLACEMENT AND RE-INSTALLATION OF ROOFTOP
UNITS SHALL BE PERFORMED BY A CONTRACTOR LICENSED
TO PERFORM SUCH WORK. COORDINATE THIS WORK WITH
THE OWNER.
NOTE: AT ROOF CURB/WALL FLASHING HEIGHTS GREATER THAN
24-INCHES: PROVIDE INTERMEDIATE SECUREMENT PER
THE REQUIREMENTS AND RECOMMENDATIONS OF THE
EPDM ROOFING MEMBRANE MANUFACTURER.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING CORNERS
FOLLOWING THE RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE MANUFACTURER. PROVIDE
"T-JOINT COVERS" AT THE BASE OF THE CURB AT FLASHING
PIECE INTERSECTIONS.
NOTE: APPLY WATER CUT OFF MASTIC TO THE BACKSIDE OF
FLASHING PRIOR TO COUNTERFLASIHNG INSTALLATION.
USE COUNTERFLASHING AS SECUREMENT PIECE FOR
FLASHING AS SHOWN.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
SPECIFIED POLYISOCYANURATE INSULATION
EXISTING STRUCTURAL DECK
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
APPROX.
1/2"
EPDM FLASHING MEMBRANE, FULLY ADHERED TO CURB. REFER TO
NOTE REGARDING SECUREMENT OF FLASHING.
REINFORCED PERIMETER FASTENING STRIP WITH FACTORY-LAMINATED
SEAM TAPE. PRIME EPDM MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 12-INCHES O.C. MAX.
UNDERLAYMENT
EXISTING OR NEW ROOF HATCH
ON CURB - RAISE TO
ACCOMMODATE NEW ROOF
SYSTEM ELEVATION, AND
RE-SECURE FLANGE TO WOOD
BLOCKING AS SHOWN. PROVIDE
INTERIOR FINISH REPAIRS AS
NEEDED TO ACCOMMODATE
RAISING OF CURB.
NOMINAL WOOD BLOCKING.
THICKNESS TO MATCH EXISTING
COVER BOARD AND INSULATION
THICKNESS; WIDTH GREATER
THAN ROOF HATCH CURB AND
CURB FLANGE. SECURE TO
SUBSTRATE 18-INCHES O.C.
WITH SPECIFIED FASTENERS
APPROPRIATE FOR THE
SUBSTRATE ENCOUNTERED.
PREFINISHED 24 GA. GALV.
STEEL SLIP COUNTERFLASHING.
SECURE TO EXISTING CURB
COUNTERFLASHING AS SHOWN
USING GASKETED FASTENERS
12-INCHES O.C. MAX., AND
WITHIN 2-INCHES OF EACH END.
APPLY SEALANT TO BACKSIDE
OF COUNTERFLASHING PRIOR
TO INSTALLATION.
NEW SAFETY POST.
CL
NOTE: PRIOR TO SOLDERING OF STAINLESS STEEL, CLEAN WORK AREA USING SOLVENTS
AND WIRE BRUSH; REMOVING DIRT, OIL, GREASE, AND OTHER CONTAMINANTS FROM
THE WORK AREA. TIN THE WORK AREA BY APPLYING ACID (FLUX). PERFORM
SOLDERING WORK. AFTER COMPLETION OF WORK, REMOVE EXCESS ACID (FLUX)
FROM THE WORK AREA.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
CL
MIN. 1" AIR
GAP OR MATCH
EXIST. - WHICHEVER
IS GREATER
4" M
IN
8" M
IN
. F
LA
SH
IN
G
H
EI
G H
T
FIELD-FABRICATED
FLASHING
HOT STACK
NOTE: APPLY PRIMER TO ALL SURFACES WHICH WILL
RECEIVE PRESSURE SENSITIVE OUTER SEAM
FLASHING PRIOR TO APPLICATION.
3" MIN3" MIN
2 1/2"
NOTE: WHEN OUTSIDE DIAMETER OF THE PIPE
EXCEEDS 18", ADDITIONAL FIELD MEMBRANE
SECUREMENT REQUIRED. REFER TO
MANUFACTURER'S DETAILS.
PRESSURE-SENSITIVE
FLASHING - 12-INCH WIDTH.
PRESSURE-SENSITIVE
FLASHING - 9-INCH WIDTH.
PRESSURE-SENSITIVE
FLASHING - 5 OR 6-INCH
WIDTH.
PRESSURE-SENSITIVE
OUTERSEAM FLASHING;
6-INCH WIDTH. SEAL
EDGES AS SHOWN.
PRE-FABRICATED
BOOT FLASHING
EXISTING TUBULAR
PENETRATION
PIPE EXTENSION (IF NECESSARY) TO
ACHIEVE 8" MIN. FLASHING HEIGHT.
PROVIDE SEALANT AT INTERSECTION
BETWEEN EXISTING TUBULAR
PENETRATION AND EXTENSION.
24 GA. STAINLESS STEEL STORM COLLAR
SOLDER ALL LAPS AND SEAMS WATERTIGHT.
REFER TO NOTE REGARDING SOLDERING.
INSTALL BUTYL TAPE BEHIND COLLAR AS
SHOWN PRIOR TO INSTALLATION OF CLAMP.
SEAL TOP OF HOOD AS SHOWN.
SEALANT - TYP
STAINLESS STEEL CLAMPING
BAND
STAINLESS STEEL CLAMPING BAND.
PRIOR TO INSTALLATION, APPLY
MANUFACTURERS RECOMMENDED
SEALANT BEHIND EPDM FLASHING.
SEAL TOP OF FLASHING AND BAND
AFTER INSTALLATION.
EXISTING HIGH-TEMPERATURE
TUBULAR PENETRATION
PRESSURE-SENSITIVE FLASHING - 12-INCH
WIDTH.
PRESSURE-SENSITIVE FLASHING - 9-INCH
WIDTH.
PRESSURE-SENSITIVE FLASHING - 5 OR
6-INCH WIDTH.
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; 6-INCH WIDTH. SEAL EDGES
AS SHOWN.
SEALANT - TYP
STAINLESS STEEL
CLAMPING BAND
SPECIFIED POLYISOCYANURATE INSULATION - TYP.
EXISTING STRUCTURAL DECK - TYP.
COVER BOARD - 1/2-INCH THICK - TYP.
EPDM ROOFING MEMBRANE - TYP.
UNDERLAYMENT - TYP.
24 GA. STAINLESS STEEL STORM COLLAR
SOLDER ALL LAPS AND SEAMS
WATERTIGHT. REFER TO NOTE
REGARDING SOLDERING. INSTALL BUTYL
TAPE BEHIND COLLAR AS SHOWN PRIOR
TO INSTALLATION OF CLAMP. SEAL TOP
OF HOOD AS SHOWN.
24 GA. STAINLESS STEEL FLANGED
SLEEVE. SOLDER ALL LAPS AND SEAMS
WATERTIGHT. REFER TO NOTE
REGARDING SOLDERING. SECURE TO
STRUCTURAL DECK AS SHOWN.
NOTE: EXISTING FLANGED SLEEVE
COMPONENTS DETERMINED TO BE IN
GOOD CONDITION AND FREE OF
BITUMINOUS CONTAMINATION MAY BE
CONSIDERED FOR RE-USE.
PREFINISHED 24 GA. GALV. STEEL
SURFACE-MOUNTED
COUNTERFLASHING. SECURE TO
EXISTING CURB COUNTERFLASHING
AS SHOWN USING GASKETED
FASTENERS 12-INCHES O.C. MAX.,
AND WITHIN 2-INCHES OF EACH END.
SELF-ADHERING MEMBRANE
COMPATIBLE WITH EXISTING
SUBSTRATE(S)
REFER TO DETAILS BELOW FOR
FLASHING REQUIREMENTS.
ALT. COUNTERFLASHING NO. 2
FOR USE WHERE APPROVED AND WHERE
EXISTING CURB IS SEPARATED FROM THE
EXISTING ROOFTOP PENETRATION
BUTYL TAPE - INSTALL BEHIND
COUNTERFLASHING
SEALANT
NOTE: SECURE TOP EDGE OF FLASHING USING AN
ALUMINUM TERMINATION BAR SECURED
12-INCHES O.C., MAX., AND WITHIN
2-INCHES OF EACH END. PRIOR TO
TERMINATION BAR INSTALLATION, INSTALL
MANUFACTURERS RECOMMENDED
SEALANT BEHIND FLASHING WHERE
TERMINATION BAR WILL BE PLACED. SEAL
TOP EDGE OF FLASHING AND TERMINATION
BAR AFTER INSTALLATION.
NOTE: INSTALL INSIDE AND OUTSIDE FLASHING
CORNERS FOLLOWING THE
RECOMMENDATIONS AND REQUIREMENTS
OF THE ROOFING MEMBRANE
MANUFACTURER. PROVIDE "T-JOINT
COVERS" AT THE BASE OF THE CURB AT
FLASHING PIECE INTERSECTIONS.
ALT. VERTICAL MEMBRANE TERMINATION
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
4" M
IN
8" M
IN
FL
AS
H
IN
G H
EI
G
H T
NOTE: DIS-CONNECTIONS AND RE-CONNECTIONS
OF ELECTRICAL, PLUMBING OR
MECHANICAL CONNECTIONS RELATED TO
THE DISPLACEMENT AND RE-INSTALLATION
OF ROOFTOP UNITS SHALL BE PERFORMED
BY A CONTRACTOR LICENSED TO PERFORM
SUCH WORK. COORDINATE THIS WORK
WITH THE OWNER.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT
SHOWN FOR CLARITY.
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
BATTEN STRIP OR FASTENERS AND 2-INCH PLATES,
12-INCHES O.C. MAX.
1-1/4" 1/2"
APPR
O
X.
2-3/4"
EPDM MEMBRANE, FULLY ADHERED TO CURB. 8" MIN.
HEIGHT, REFER TO NOTE REGARDING SECUREMENT
OF FLASHING.
ALT. VERTICAL TERMINATION -
TWO PIECE FLASHING
FOR USE WHERE HORIZONTAL TERMINATION OF
EPDM MEMBRANE IS NOT POSSIBLE
1-1/4" 1/2"
2-3/4"
EPDM ROOFING MEMBRANE
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER
TO UNDERLYING EPDM ROOF MEMBRANE
AND OVERLYING EPDM FLASHING
MEMBRANE PRIOR TO APPLICATION.
BATTEN STRIP OR FASTENERS AND 2-INCH
PLATES, 12-INCHES O.C. MAX.
PRESSURE-SENSITIVE OUTERSEAM
FLASHING; MIN. 5-INCH WIDTH. SEAL
EDGES AS SHOWN.
4" M
IN
WRAP EPDM MEMBRANE FLASHING OVER
THE TOP OF THE CURB AND SECURE TO
THE INSIDE OF THE CURB WITH 1" METAL
CAP NAILS AT 6" O.C. MAXIMUM.
MEMBRANE SECUREMENT
PREFINISHED 24 GA. GALV.
STEEL SLIP COUNTERFLASHING.
SECURE TO EXISTING CURB
COUNTERFLASHING AS SHOWN
USING GASKETED FASTENERS
12-INCHES O.C. MAX., AND
WITHIN 2-INCHES OF EACH END.
EXISTING ROOFTOP UNIT
COUNTERFLASIHNG
REFER TO DETAILS BELOW FOR
FLASHING REQUIREMENTS.
ALT. COUNTERFLASHING NO. 1
FOR USE WHERE APPROVED AND WHERE EXISTING
ROOFTOP UNIT CANNOT BE DISPLACED TO ALLOW FOR
FLASHING, OR WHERE GAP BETWEEN EXISTING
ROOFTOP UNIT COUNTERFLASHING AND CURB IS TOO
NARROW TO ACCOMMODATE FLASHING
4" M
IN
8" M
IN
FL
AS
H
IN
G H
EI
G
H T
EXIST. ROOFTOP PENETRATION
ALT. NOTE:
ALT. SECUREMENT
APPROX.
1/2"
SEAM TAPE - 6-INCH WIDTH. APPLY PRIMER TO
UNDERLYING EPDM ROOF MEMBRANE AND OVERLYING
EPDM FLASHING MEMBRANE PRIOR TO APPLICATION.
2"
PRESSURE-SENSITIVE OUTERSEAM FLASHING;
MINIMUM 5-INCH WIDTH. SEAL EDGES AS SHOWN.
ALT. TWO-PIECE FLASHING
EPDM FLASHING, 8" MIN. HEIGHT, FULLY
ADHERED TO CURB. REFER TO NOTE
REGARDING SECUREMENT OF MEMBRANE.
EXISTING STRUCTURAL DECK
WOOD BLOCKING - IF NECESSARY TO ACHIEVE
8-INCH MINIMUM FLASHING HEIGHT. SECURE TO
SUBSTRATE 18-INCHES O.C. AND WITHIN 2-INCHES
OF EACH END.
EXISTING ROOFTOP UNIT - TEMPORARILY DISPLACE
TO ALLOW FOR INSTALLATION OF NEW ROOF
SYSTEM AND RELATED FLASHING COMPONENTS.
REINSTALL TO ORIGINAL POSITION AFTER
COMPLETION OF WORK. RE-SECURE TO EXISTING
CURB WITH GASKETED FASTENERS 12-INCHES O.C.
MAX., AND WITHIN 2-INCHES OF EACH CORNER.
CURB INSULATION - IF EXISTING
CURB IS INSULATED, AND
EXISTING INSULATION CANNOT BE
SALVAGED, PROVIDE CURB
INSULATION TO MATCH EXISTING.
4" M
IN
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
REINFORCED PERIMETER FASTENING STRIP WITH
FACTORY-LAMINATED SEAM TAPE. PRIME EPDM
MEMBRANE PRIOR TO APPLICATION TO REINFORCED
FASTENING STRIP.
FASTENERS AND 2-INCH PLATES, 6-INCHES O.C. MAX.
EPDM MEMBRANE, 8" MIN. HEIGHT, FULLY
ADHERED TO CURB. REFER TO NOTE
REGARDING SECUREMENT OF MEMBRANE.
APPROX.
1/2"
SPECIFIED POLYISO. INSULATION
EXISTING STRUCTURAL DECK
EPDM RFG.
MEMBRANE
APPR
O
X.
2-3/4"
STARTER COARSE OF
ASPHALT SHINGLES
SELF-ADHERING MEMBRANE
DRIP EDGE METAL - NAIL
8-INCHES O.C.; 4-INCHES
O.C. IN HIGH-WIND ZONES
(DESIGN WIND SPEED
GREATER THAN 90 MPH).
SELF-ADHERING MEMBRANE
STRIPPING PLY
UNDERLAYMENT
SEALING STRIP
GUTTER - REFER TO ADJACENT
DETAIL FOR FURTHER
CLARIFICATION.
DOWNSPOUT RECEIVER PIECE - FABRICATE USING PREFINISHED 24
GA. GALV. STEEL. FASTEN AND SEAL TO GUTTER AS SHOWN.
PREFINISHED 24 GA. GALV. STEEL GUTTER.
FABRICATE GUTTER IN ACCORDANCE WITH
"SMACNA" STYLE "D". JOINTS IN GUTTERS
MUST BE LAPPED 1-1/2 INCH, RIVETED
1-INCH O.C. SEALED WITH SEALANT.
GUTTER SPACERS - 1-INCH WIDE X
1/8-INCH THICK, SPACED 24-INCHES O.C.
MAX. SEAL AND SECURE TO GUTTER AS
SHOWN.
6" MIN.
6" M
IN
3" M
IN
PREFINISHED 24 GA. GALV. STEEL 4-INCH X 5-INCH RECTANGULAR
DOWNSPOUT. FABRICATE AND INSTALL DOWNSPOUTS IN
ACCORDANCE WITH THE REQUIREMENTS AND RECOMMENDATIONS OF
THE SPECIFICATIONS AND SMACNA. SECURE DOWNSPOUT TO WALL
WITH BRACKETS AND FASTENERS APPROPRIATE FOR THE SUBSTRATE
ENCOUNTERED. TERMINATE BOTTOM OF DOWNSPOUT TO MATCH
EXISTING.
1" M
IN
EXTEND SELF-ADHERING MEMBRANE
24-INCHES MIN. BEYOND INTERIOR WALL OF
BUILDING ENVELOPE. LAP UPSLOPE
UNDERLAYMENT OVER SELF-ADHERING
MEMBRANE 4-INCHES MIN., SHINGLE-STYLE
AS SHOWN.
3"
2"
DRIP EDGE METAL: PREFINISHED 24 GA.
GALV. STEEL WITH A MINIMUM 3-INCH
FLANGE. SECURE 8-INCHES O.C.; 4-INCHES
O.C. IN HIGH-WIND ZONES (DESIGN WIND
SPEED GREATER THAN 90 MPH).
PREFINISHED 24 GA. GALV. STEEL FASCIA EXTENSION. SECURE VERTICAL
FACE WITH FASTENERS APPROPRIATE FOR THE SUBSTRATE
ENCOUNTERED 12-INCHES O.C. MAX.; DECREASE FASTENER SPACING TO
6-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.
NOTE: CONFIGURATION OF FASCIA MAY VARY. FIELD-VERIFY
CONFIGURATION AND DIMENSIONS.
AXONOMETRIC VIEW
SCALE: NONE
SECTION VIEW
SCALE: NONE
SL
OPE
SELF-ADHERING MEMBRANE
ASPHALT SHINGLES. SECURE EACH FULL-LENGTH
SHINGLE WITH SIX ROOFING NAILS.
EXISTING STRUCTURAL DECK
PREFINISHED 24 GA. GALV. STEEL DRIP EDGE METAL. FABRICATE WITH A MINIMUM
3-INCH HORIZONTAL FLANGE. FABRICATE FASCIA TO MATCH EXISTING; WITH A
MINIMUM FASCIA DIMENSION OF 2-INCHES. SECURE 8-INCHES O.C.; 4-INCHES O.C. IN
HIGH-WIND ZONES (DESIGN WIND SPEED GREATER THAN 90 MPH).
SPECIFIED UNDERLAYMENT; LAP 4-INCHES
OVER SELF-ADHERING UNDERLAYMENT
TO
M
AT
C
H
EX
IS
TI
N G
; 2
M
IN
IM
U
M
RAKE EDGE FLANGE - NAIL
8-INCHES O.C.; 4-INCHES O.C. IN
HIGH-WIND ZONES (DESIGN WIND
SPEED GREATER THAN 90 MPH).
ASPHALT SHINGLES
SELF-ADHERING
MEMBRANE
SEALING STRIP
3"
2"
EXTEND SELF-ADHERING MEMBRANE 24-INCHES MIN.
BEYOND INTERIOR WALL OF BUILDING ENVELOPE. LAP
UPSLOPE UNDERLAYMENT OVER SELF-ADHERING
MEMBRANE 4-INCHES MIN., SHINGLE-STYLE AS
SHOWN.
AXONOMETRIC VIEW
SCALE: NONE
SECTION VIEW
SCALE: NONE
SELF-ADHERING MEMBRANE - LAP 4-INCHES OVER
UNDERLAYMENT
ASPHALT SHINGLES. SECURE EACH FULL-LENGTH
SHINGLE WITH SIX ROOFING NAILS.
EXISTING STRUCTURAL DECK
ASPHALT HIP SHINGLES. SECURE WITH ROOFING
NAILS. SEAL EXPOSED NAILS.
RIDGE/HIP FLASHING DETAIL
NOTE: DO NOT INSTALL ASPHALT SHINGLES CONFIGURED WITH RIDGE VENTS AT
HIPS. EXTEND SELF-ADHERING MEMBRANE OVER HIP (18-INCHES ON EACH SIDE
OF HIP, AND OVERLAP OVER UNDERLAYMENT 4-INCHES, MIN.).
18" MIN.
BOTH SIDES OF HIP 4"
LAP
UNDERLAYMENT
ASPHALT SHINGLES - SECURE EACH FULL-LENGTH
SHINGLE WITH SIX ROOFING NAILS. NOTCH
SHINGLES AS SHOWN TO ACCOMMODATE TUBULAR
PENETRATION FLASHING.
NOTE: FIELD UNDERLAYMENT AND ROOFING DECK NOT SHOWN FOR CLARITY
FASTEN FLANGE OR PREFABRICATED METAL
FLASHING AS RECOMMENDED BY MANUFACTURER.
SEAL FASTENER HEADS AFTER INSTALLATION.
APPLY NEW
SEALANT UNDER
SHINGLES
LAP UNDERLAYMENT
OVER FLASHING
SOFT-METAL FLASHING SLEEVE
ROLL INTO VENT PIPE 1" MIN.
SEALING STRIP
EXISTING PLYWOOD
DECK
SPECIFIED UNDERLAYMENT
SEALANT
SPECIFIED UNDERLAYMENT
OVER FLASHING
PIPE PENETRATION METAL
SLEEVE FLASHING
SEALANT
1" M
IN
TOP VIEW
DETAIL
SCALE: NONE
4" M
IN
4" M
IN
6" MIN. 6" MIN.
6" M
IN
6" M
IN
36" SELF ADHERING MEMBRANE
2"
24 GA. GALV. STEEL FLASHING - SOLDER ALL
JOINTS WATERTIGHT - SET IN A SOLDER BED
OF MASTIC SECURED 4" O.C. MAX. - EXPOSED
FASTENERS SHALL BE SCREWS WITH EPDM
WASHERS
SELF-ADHERING MEMBRANE.
EXTEND UPSLOPE 24-INCHES MIN.,
BEYOND INTERIOR WALL OF THE
BUILDING ENVELOPE AS SHOWN.
EXTEND SELF-ADHERING MEMBRANE
OVER FLANGE OF PERIMETER EDGE
FASCIA METAL AS SHOWN.
ASPHALT SHINGLES. SECURE EACH
FULL-LENGTH SHINGLE WITH SIX
ROOFING NAILS.
EXISTING STRUCTURAL DECK
AT LOCATIONS WHERE FASCIA DIMENSION EXCEEDS 5-INCHES: 22 GA.
GALV. STEEL CONTINUOUS CLEAT. SECURE WITH FASTENERS
APPROPRIATE FOR THE SUBSTRATE ENCOUNTERED 12-INCHES O.C.
MAX.; DECREASE FASTENER SPACING TO 6-INCHES O.C. WITHIN
10-FEET OF A BUILDING CORNER.
PERIMETER FASCIA METAL: PREFINISHED 24
GA. GALV. STEEL WITH A MINIMUM 3-INCH
FLANGE. HOOK TO CONTINUOUS CLEAT (IF
APPLICABLE) AND SECURE 8-INCHES O.C.;
4-INCHES O.C. IN HIGH-WIND ZONES (DESIGN
WIND SPEED GREATER THAN 90 MPH).
EXTEND SELF-ADHERING MEMBRANE 24-INCHES MIN.
BEYOND INTERIOR WALL OF BUILDING ENVELOPE. LAP
UPSLOPE UNDERLAYMENT OVER SELF-ADHERING
MEMBRANE 4-INCHES MIN., SHINGLE-STYLE AS
SHOWN.
TO
M
AT
C
H E
XI
ST
IN
G
; 2 " M
IN
IM
U M
N O
TE
PR
O
VI
D
E
G A.
G
AL
V.
S
TE
EL
C O
N
TI
N U
O U
S C
LE
AT
A S
SH
O
W N
W H
ER
E
FA
SC
IA
D
IM
EN
SI
O
N
IS
G R
EA
TE
R T
H
AN
3"
2"
SELF-ADHERING MEMBRANE STRIPPING PLY
OVER FLANGE. EXTEND 4-INCHES, MIN.
BEYOND BACK EDGE OF FLANGE.
STARTER COARSE OF
ASPHALT SHINGLES
SELF-ADHERING MEMBRANE
DRIP EDGE FASCIA - NAIL
8-INCHES O.C.; 4-INCHES
O.C. IN HIGH-WIND ZONES
(DESIGN WIND SPEED
GREATER THAN 90 MPH).
SELF-ADHERING MEMBRANE
STRIPPING PLY
UNDERLAYMENT
SEALING STRIP AXONOMETRIC VIEW
SCALE: NONE
SECTION VIEW
SCALE: NONE
PRIOR TO THE INSTALLATION OF FASCIA & UNDERLAYMENT CONTRACTOR TO
INSTALL LIQUID APPLIED FLASHING SYSTEM - EMBED MANUFACTURES
RECOMMENDED FABRIC INTO FIRST COAT
6" MIN.
6"
1" M
IN
6"
3" M
IN
2" M
IN
. O
R T
O M
AT
C
H E
XI
ST
IN
G
E
LE
VA
TI
O N
W H
IC
H
EV
ER
IS
G
R
EA
TE
R
4"
1/2" HUG
GUTTER EDGE FLANGE CONFIGURATION
AND NAILING PATTERN DIAGRAM
SCALE: NONE
NOTE: THE PURPOSE OF THIS DIAGRAM IS
TO SHOW GUTTER EDGE FASCIA FLANGE
FASTENING PATTERNS AND NAILER
CONFIGURATION. THE ACTUAL FASCIA
CONFIGURATION, SIZE OF NAILERS, AND
NUMBER OF NAILERS REQUIRED TO
ACHIEVE THE REQUIREMENTS SHOWN IN
THE DETAIL BELOW WILL VARY.
3" MIN.
4" FLANGE
1/2" HUG
6" MIN.
1/2" MIN.
NOTE: EXTEND EPDM ROOFING MEMBRANE OVER AND DOWN
PERIMETER EDGE AS SHOWN. SECURE WITH ROOFING
NAILS AFFIXED WITH 1" DIAMETER METAL CAPS 12" O.C.
MAX.
NOTE: TAPERED INSULATION, IF SPECIFIED, IS NOT SHOWN FOR
CLARITY.
DOWNSPOUT RECEIVER PIECE - FABRICATE USING PREFINISHED 24 GA.
GALV. STEEL. FASTEN AND SEAL TO GUTTER AS SHOWN.
PREFINISHED 24 GA. GALV. STEEL FASCIA EXTENSION PIECE. SECURE
TO SUBSTRATE WITH SPECIFIED FASTENER APPROPRIATE FOR THE
SUBSTRATE ENCOUNTERED 12" O.C. MAX.
PROVIDE GUTTER HANGERS 30-INCHES O.C. - FABRICATE FROM 1-INCH X
1/8-INCH GALV. STEEL, PAINTED TO MATCH GUTTER. SECURE TO
SUBSTRATE WITH FASTENERS APPROPRIATE FOR THE SUBSTRATE
ENCOUNTERED. SECURE WITH TWO FASTENERS, MINIMUM, PER HANGER.
UNDERLAYMENT
PRESSURE-SENSITIVE OUTER SEAM FLASHING - 5-INCH OR
6-INCH WIDTH.
NOTE: AT A MINIMUM, PROVIDE AN ADDITIONAL 6" WIDE
REINFORCEMENT PIECE AT SHEET METAL FASCIA JOINTS.
REFER TO ROOFING MEMBRANE MANUFACTURER
REQUIREMENTS FOR ADDITIONAL REQUIREMENTS AND
RECOMMENDATIONS AT SHEET METAL FASCIA JOINTS.
NOMINAL 6-INCH WOOD BLOCKING - THICKNESS AS NECESSARY TO
MATCH MAXIMUM ROOF AREA INSULATION AND COVER BOARD
THICKNESS WITH A CONSISTENT FINAL NAILER ELEVATION. SECURE
TO SUBSTRATE 18-INCHES O.C. MAX. DECREASE FASTENER SPACING
TO 9-INCHES O.C. WITHIN 10-FEET OF A BUILDING CORNER.
TAPERED POLYISOCYANURATE INSULATION
MINIMUM STARTING THICKNESS OF 1-INCH
EXISTING STRUCTURAL DECK
SPECIFIED POLYISOCYANURATE INSULATION
COVER BOARD - 1/2-INCH THICK
EPDM ROOFING MEMBRANE
GUTTER FABRICATED FROM 24 GA.
PREFINISHED GALV. STEEL. OVERLAP
GUTTER SECTIONS 1-1/2 INCH, SEAL, AND
POP RIVET SECTIONS WITH TWO ROWS OF
POP RIVETS, SPACED 1/2"-3/4" O.C. IN EACH
ROW. SECURE BACK VERTICAL FLANGE
TO SUBSTRATE 18" O.C. MAX.
PRESSURE-SENSITIVE OUTER SEAM
FLASHING - 9-INCH WIDTH. SEAL EDGES
AS SHOWN AFTER COMPLETION OF
WORK.
GUTTER SPACERS - 1/8-INCH THICK BY
1-INCH WIDE, 30-INCHES O.C. MAX.
FABRICATE FROM GALVANIZED STEEL.
PAINT SPACERS TO MATCH GUTTER COLOR.
SEAL AND SECURE TO GUTTER.
PREFINISHED 24 GA. GALV. STEEL RECTANGULAR…
This is the start of the file's text. The full file is on GovTribe.