ATTACHMENT J-13 Fire and Flood.docx

DOCX document 649 KB Posted

Attached to
Operation and Maintenance of Philadelphia Inactive Vessels and CG/LSD Modernization Detachment Norfolk
Solicitation number
N00024-21-R-4203
Issued by

About this file

This document contains inspection guidelines for fire and flood systems on ships. The guidelines include procedures for testing alarm circuits and sensors for heat, smoke, and flooding. Inspectors are directed to check continuity of alarm circuits, activate flooding sensors by tipping floats or shorting probes, manually operate sensors to check remote monitoring, and activate heat sensors using a hot air gun. Inspectors must record results and report any discrepancies. The periodic inspections are conducted according to Naval Sea Systems Command specifications.

View the file

Other files

File Type Posted
QA Master List 2 Nov 2021.xlsx XLSX spreadsheet
Attachment J-2 Cost Element Summary Spreadsheets Amendment 0001_Rev1.xlsx XLSX spreadsheet
N00024-21-R-4203 Conformed through Amendment 0006.pdf PDF
N00024-21-R-4203 Amendment 0006.pdf PDF
N00024-21-R-4203 Amendment 0005.pdf PDF
QA Master List 12 Oct 2021.xlsx XLSX spreadsheet
N00024-21-R-4203 Amendment 0004.pdf PDF
N00024-21-R-4203 Amendment 0003.pdf PDF
N00024-21-R-4203 Amendment 0002.pdf PDF
QA Master List 06 Oct 2021.xlsx XLSX spreadsheet
ATTACHMENT J-22 INACTSHIPMAINTO Philadelphia Organizational Chart .pdf PDF
N00024-21-R-4203 Amendment 0001_rev1.pdf PDF
Attachment J-2 Cost Element Summary Spreadsheets Amendment 0001.xlsx XLSX spreadsheet
N00024-21-R-4203 Amendment 0001.pdf PDF
QA Master List 05 Oct 2021.xlsx XLSX spreadsheet
ATTACHMENT J-12 Dehumidification.docx DOCX document
Attachment J-1 Pre-Proposal Information Form.xlsx XLSX spreadsheet
ATTACHMENT J-7 Janitorial Task and Frequency Chart.xlsx XLSX spreadsheet
Attachment J-20 Quality Assurance Surveillance Plan.doc DOC document
ATTACHMENT J-17 Fire Extinguisher Log.docx DOCX document
ATTACHMENT J-3 VESSELS.xls XLS spreadsheet
ATTACHMENT J-19 PCB Inventory.doc DOC document
ATTACHMENT J-10 Tools and Material.xls XLS spreadsheet
CDRL33_36.pdf PDF
CDRL41_44.pdf PDF
ATTACHMENT J-6 History Folder Index.docx DOCX document
CDRL17-20.pdf PDF
ATTACHMENT J-15 Arrival Inspection.docx DOCX document
ATTACHMENT J-8 GFE from NAVY ERP.xls XLS spreadsheet
ATTACHMENT J-9 Vehicles.xlsx XLSX spreadsheet
CDRL13-16.pdf PDF
CDRL45-48.pdf PDF
CDRL29-32.pdf PDF
CDRL53-54.pdf PDF
N00024-21-R-4203 RFP.pdf PDF
ATTACHMENT J-4 - Tank Soundings Template.xls XLS spreadsheet
Exhbt B - Past Performance Data.docx DOCX document
CDRL05_08.pdf PDF
Attachment J-21 DD 254 for N00024-21-R-4203.pdf PDF
Attachment J-2 Cost Element Summary Spreadsheets.xlsx XLSX spreadsheet
CDRL49-52.pdf PDF
CDRL37_40.pdf PDF
ATTACHMENT J-16 Security Report.doc DOC document
CDRL21-24.pdf PDF
ATTACHMENT J-5 RRWO.docx DOCX document
CDRL09_12.pdf PDF
Exhbt C - Past Performance Questionnaire.docx DOCX document
ATTACHMENT J-14 Integrity Inspection.docx DOCX document
ATTACHMENT J-18 Mooring.xlsx XLSX spreadsheet
CDRL01_04.pdf PDF
Show 40 more

Latest 50 of 52 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Periodicity:

Spec Code:

Berthed At:

Quarter:

NSTM 50 INSPECTION GUIDELINES

FF1

Insp Date:

TDL

Remarks N/A

NO

YES

Description Item Check continuity of each heat, smoke and flood alarm circuit at the control panel. Record results below. Are all readings satisfactory?

Have all other discrepancies been reported? If not report them here.

F/F Continuity FWD Draft:

AFT Draft:

List:

Comments:

Inspector Inspector Inspection Manager Circuit Continuity Test Results SW No.

Cir Type K Ohm Test Location Sat Unsat SW No.

Cir Type K Ohm Test Location Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat Sat Unsat

Attachment 12 NSTM 50 INSPECTION GUIDELINES - Discrepancy Listing Spec Code:

Line Item # Location Discrepancy Discovery Dt Correction Dt

Berthed At:

Quarter:

NSTM 50 INSPECTION GUIDELINES

FF2

Insp Date:

TDL

Remarks N/A

NO

YES

Description Item Audible alarm and alarm light are activated by the test switch?

Is the power available light energized at all times except during continuity testing ?

Does test switch indicate proper vessel and alarm on remote monitoring computer; can alarm be silenced from remote monitoring computer?

Have all other discrepancies been reported? If not report them here.

Fire Panel FWD Draft:

AFT Draft:

List:

Comments:

Inspector Inspector Inspection Manager

Line Item # Location Discrepancy

Berthed At:

Quarter:

NSTM 50 INSPECTION GUIDELINES

FF3

Insp Date:

TDL

Remarks N/A

NO

YES

Description Item Activate all flooding sensors by tipping floats or shorting probes to check for proper operation.

Are sensor cutout switches numbered and chart present? Do cutouts isolate alarms circuit as indicated on chart?

All sensors operated mannually indicate proper vessel and location on remote monitoring systems.

Are Fire/Flood sensors correctly located in respect to electrical power and water tight sub-division of a ship?

Visual and audible alarms activate when the sensor is actuated.

Each fire wire heat sensor is activated.

Each smoke detector is activated using canned smoke to ensure its proper operation.

Have all other discrepancies been reported? If not report them here.

Flood Tip Float (MOB B) FWD Draft:

AFT Draft:

List:

Comments:

Inspector

Line Item # Location Discrepancy

Berthed At:

Quarter:

NSTM 50 INSPECTION GUIDELINES

FF4

Insp Date:

TDL

Remarks N/A

NO

YES

Description Item Visual and audible alarms activate when the sensor is actuated.

Activate all flooding sensors by tipping floats or shorting probes to check for proper operation.

Are sensor cutout switches numbered and chart present? Do cutouts isolate alarms circuit as indicated on chart?

All sensors operated mannually indicate proper vessel and location on remote monitoring systems.

Are Fire/Flood sensors correctly located in respect to electrical power and water tight sub-division of a ship?

Each heat sensor is activated using a hot air gun to ensure its proper operation. (exercise extreme caution to prevent damage to heat dectecting element due to overheating) Each smoke detector is activated using canned smoke to ensure its proper operation.

Have all other discrepancies been reported? If not report them here.

Flood Tip Float (Non MOB B) FWD Draft:

AFT Draft:

List:

Comments:

Inspector

Line Item # Location Discrepancy

File details come from the government source that posted it. Updated .