This document is a set of drawings titled "Attachment F - USU Roof Garden" related to a U.S. Navy construction contract opportunity. The contract is an Indefinite-Delivery/Indefinite-Quantity (IDIQ) Small Business Multiple Award Construction Contract for roofing and renovation work on various facilities within the NAVFAC Washington Area of Responsibility. The contract has a total estimated construction value of up to $249 million over an 8-year period, with individual task orders ranging from $150,000 to $15 million. The contract covers a variety of construction activities including new construction, demolition, repair, and renovation of roofing systems and related building components. The drawings appear to provide specifications for a "Roof Garden" project at an unspecified location. No further details about the specific requirements or scope of this drawing set are provided.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
NAVAL FACILITIES ENGINEERING COMMAND
(NAVFAC)
UNIFORMED SERVICES UNIVERSITY OF THE
HEALTH SERVICES
BETHESDA, MD
1. ARCHITECT:
MTFA ARCHITECTURE INC.
3200 LANGSTON BOULEVARD
ARLINGTON, VA 22207
2. STRUCTURAL ENGINEER:
MCMULLAN CONSULTING ENGINEERS
11800 SUNRISE VALLEY DR., SUITE 430
RESTON, VA 20191
3. MECHANICAL, ELECTRICAL, PLUMBING AND FIRE PROTECTION
/ LIFE SAFETY:
SUMMER CONSULTANTS, INC.
7900 WESTPARK DRIVE, SUITE A405
MCLEAN, VA 22102
4. LANDSCAPE:
OEHME, VAN SWEDEN
800 G STREET SE,
WASHINGTON D.C. 20003
5. HAZARDOUS MATERIALS:
TIDEWATER, INC.
6625 SELNICK DRIVE, SUITE A
ELKRIDGE, MD 21075
6. COST ESTIMATOR:
RIB U.S. COST
241 GARRISONVILLE RD., SUITE 202
STAFFORD, VA 22554
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S
TE
M S
C O
M M
A N
D
W A
S H
IN
G
TO
N
N A
V A
L S
U P
P O
R T
A C
T
IV
IT
Y
B E
T H
E S
D A
M
A R
Y L
A N
D
AS NOTED
P U
B L
IC
W
O R
K S
D E
P A
R T
M E
N T
B
E T
H E
S D
A
3200 LANGSTON BOULEVARD, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 9635,
EXPIRATION DATE 8/15/23.
/2
/2
:1
:1
P
M
G-001
B u ild in g
E
R o o f G a rd e n
C O
V E
R S
H E
E T
BB
13148358
MJB CBM
FINAL DESIGN SUBMISSION
1698751
B E
T H
E S
D A
, M D
U N
IF
O
R M
E D
S E
R V
IC
E
S U
N
IV
E R
S
IT
Y O
F T
H E
H E
A
LT
H S
C
IE
N C
E S
G -0
F in a l D e s ig n S u b m is s io n
/2
/2
/2
8/
F in al
D es ig n
S ub m is si on
VICINITY MAP (NTS)
LOCATION MAP (NTS)
USU- BUILDING 76E ROOF GARDEN
FINAL DESIGN SUBMISSION - JUNE 28, 2023
UNIFORMED SERVICES UNIVERSITY OF THE HEALTH SCIENCES, BETHESDA, MD.
PLAN
NORTH
PLAN
NORTH
DRAWING INDEX
SHEET # SHEET_NO NAVFAC_NO SHEET NAME
01-General
G-001 1 13148358 COVER SHEET
G-002 2 13148359 GENERAL NOTES, ABBREVIATIONS AND SYMBOLS
G-003 3 13148360 PHASING PLANS
02-Life Safety
GI001 4 13148361 BUILDING CODE SUMMARY
GI101 5 13148362 FIRST FLOOR
GI102 6 13148363 SECOND FLOOR
03-Structural
S-001 7 13148364 DESIGN NOTES
S-101 8 13148365 PARTIAL LEVEL 2 (ROOF) FRAMING PLAN
S-501 9 13148366 SECTIONS AND DETAILS
S-502 10 13148367 SECTIONS AND DETAILS
S-503 11 13148368 EXISTING CONNECTION VERIFICATION DETAILS
04-Architectural
AD101 12 13148369 LEVEL 1 DEMOLITION REFLECTED CEILING PLAN
AD102 13 13148370 LEVEL 2 DEMOLITION PLANS
AD301 14 13148371 SECTIONS - DEMO
A-101 15 13148372 OVERALL FLOOR PLAN - NEW WORK
A-102 16 13148373 LEVEL 2 - NEW WORK
A-103 17 13148374 LEVEL 2 - TRELLIS PLAN
A-111 18 13148375 LEVELS 1 & 2 RCP
A-301 19 13148376 SECTIONS
A-302 20 13148377 SECTIONS
A-501 21 13148378 DETAILS
A-502 22 13148379 DETAILS
A-503 23 13148380 RAMP PLANS AND DETAILS
A-601 24 13148381 DOOR SCHEDULE
A-701 25 13148382 RENDERED VIEWS
05-Fire Protection
FX001 26 13148383 SYMBOLS AND ABBREVIATIONS
FD101 27 13148384 FIRST FLOOR - DEMOLITION
FD102 28 13148385 SECOND FLOOR
FX101 29 13148386 SECOND FLOOR
06-Mechanical
M-001 30 13148387 SYMBOLS AND ABBREVIATIONS
MD101 31 13148388 MECHANICAL DEMO
M-101 32 13148389 MECHANICAL
M-301 33 13148390 MECHANICAL SECTIONS
07-Electrical
E-001 34 13148391 SYMBOLS AND ABBREVIATIONS
ED101 35 13148392 ELECTRICAL DEMO
ED102 36 13148393 FLOOR PLANS - POWER - DEMOLITION
E-101 37 13148394 FLOOR PLANS - ELECTRICAL
E-102 38 13148395 FLOOR PLANS - POWER
08-Fire Alarm
FA001 39 13148396 SYMBOLS AND ABBREVIATIONS
FD111 40 13148397 FIRST FLOOR - DEMOLITION
FD112 41 13148398 SECOND FLOOR
FA101 42 13148399 FIRST FLOOR
FA102 43 13148400 SECOND FLOOR
09-Landscape
L-101 44 13148401 SOILS AND GRADING
L-102 45 13148402 PLANTING PLAN
L-201 46 13148403 PLANTING DETAILS
L-301 47 13148404 IRRIGATION PLAN
L-302 48 13148458 IRRIGATION DETAILS
L-303 49 13148459 IRRIGATION DETAILS
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P R
1. WORK MUST BE PERFORMED IN ACCORDANCE WITH RULES AND REGULATIONS OF GOVERNMENT AGENCIES HAVING JURISDICTION AND MUST CONFORM TO ALL ARCHITECTURAL BARRIERS ACT (ABA) AND THE AMERICANS WITH DISABILITIES AND ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS), NFPA, CITY, COUNTY, STATE, AND FEDERAL CONSTRUCTION, SAFETY, AND SANITARY LAW, CODES, STATUTES, AND ORDINANCES.
2. ALL CONTRACTORS MUST BE RESPONSIBLE FOR VISITING THE SITE AND EXAMINING EXISTING CONDITIONS PRIOR TO SUBMITTING A BID FOR THE
WORK.
3. CONSTRUCTION OF WORK INDICATED ON THE DRAWINGS AS (N.I.C.) IS NOT IN CONTRACT.
4. WHERE SPECIFIC DIMENSIONS, DETAILS OR DESIGN INTENT CANNOT BE DETERMINED, CONSULT GOVERNMENT BEFORE PROCEEDING WITH THE WORK. TYPICAL DETAILS APPLY AT ALL SIMILAR CONDITIONS WHETHER CROSS REFERENCED OR NOT.
5. REQUIRED WORK OF A TRADE MAY BE AFFECTED BY INFORMATION ON OTHER TRADE SHEETS. ALL BIDS ARE BASED ON EXAMINATION OF A FULL SET OF DOCUMENTS. THE CONTRACTOR MUST COORDINATE THE WORK OF ALL TRADES AND SUBCONTRACTORS.
6. DIMENSION UNITS ARE IMPERIAL UNITS UNLESS NOTED OTHERWISE.
7. DIMENSIONS SHOWN ARE TO THE FINISHED FACE, CENTER-LINE OF DOOR OPENING AND COLUMN GRID LINES UNLESS NOTED OTHERWISE.
8. "VIF" OR ± INDICATED DIMENSIONS MUST BE FIELD VERIFIED. WHEN ACTUAL FIELD DIMENSIONS VARY IN SUCH A WAY THAT IT AFFECTS ELEMENTS
WITHIN THE STRING, NOTIFY GOVERNMENT IMMEDIATELY.
9. DO NOT SCALE DRAWINGS. WHERE DIMENSIONS OR EXACT LOCATIONS ARE REQUIRED AND NOT INCLUDED ON THE DRAWINGS, REQUEST
INFORMATION FROM GOVERNMENT.
10. THE INFORMATION CONTAINED HEREIN MAY REQUIRE ADJUSTMENT OR MODIFICATION TO CONFORM TO EXISTING CONDITIONS. IN CASES WHERE CHANGES IN DETAILS ARE NECESSARY, THESE DRAWINGS ARE USED TO SHOW ONLY THE DESIGN INTENT.
11. INSTALL MATERIALS, EQUIPMENT, HARDWARE, AND OTHER ELEMENTS IN STRICT COMPLIANCE WITH THE MANUFACTURER'S WRITTEN INSTRUCTIONS AND RECOMMENDATIONS. COORDINATE LOCATION OF CONCEALED SUPPORTS OR BLOCKING TO ENSURE PROPER INSTALLATION PRIOR TO
CLOSING OF WALLS.
12. ALL DAMAGE TO EXISTING CONSTRUCTION AND PROPERTY BY THE CONTRACTOR MUST BE REPLACED AT THE CONTRACTOR'S EXPENSE WITH NEW
MATERIALS TO MATCH EXISTING.
13. ELECTROLYTIC PROTECTION MUST BE PROVIDED BETWEEN DISSIMILAR METALS WHENEVER THE TWO ARE IN CONTACT.
14. OPEN EXTERIOR JOINTS AROUND WINDOW AND DOOR FRAMES, BETWEEN WALL PANELS, AT PENETRATIONS OF UTILITIES THROUGH THE BUILDING ENVELOPE MUST BE SEALED, FLASHED OR WEATHER-STRIPPED AS REQUIRED FOR COMPATIBILITY WITH ADJACENT MATERIALS TO ELIMINATE AIR
LEAKAGE & WATER INFILTRATION.
15. A FULL AND COMPLETE JOB IS REQUIRED UNDER THIS CONTRACT. MATERIAL AND LABOR WHICH ARE RELATED TO THE WORK BUT NOT SPECIFICALLY INDICATED, AND WHICH ARE REQUIRED FOR A PROFESSIONALLY FINISHED JOB, MUST BE A PART OF THE WORK.
16. WORK IS TO BE PERFORMED IN A FULLY OCCUPIED BUILDING. PERIODS OF SYSTEM INTERRUPTIONS MUST BE APPROVED BY BUILDING MANAGEMENT AND MUST BE LIMITED TO OFF HOURS/DAYS. THE GOVERNMENT AND TENANT REQUIRE A 72 HOUR NOTIFICATION OF SYSTEM INTERRUPTIONS. SEE WORK RESTRICTION IN THE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS.
17. VERIFICATION & ADJUSTMENT OF LAYOUTS IS PART OF THE SCOPE OF WORK. PROVIDE CONFIRMATION OF ALL DIMENSIONS AND LAYOUT WITH THE GOVERNMENT PRIOR TO INSTALLATION OF SYSTEMS. THE CONTRACTOR IS RESPONSIBLE FOR ON-SITE VERIFICATION OF ALL FIELD CONDITIONS, QUANTITIES, AND DIMENSIONS PRIOR TO CONSTRUCTION.
18. THE CONTRACTOR IS RESPONSIBLE FOR PAYMENT OF ALL APPLICABLE PERMITS.
19. THE GENERAL NOTES AND TYPICAL DETAILS APPLY THROUGHOUT THE JOB UNLESS OTHERWISE NOTED OR SHOWN.
20. NO MATERIAL CUTTING OR FABRICATION OF ANY WORK WILL BEGIN UNTIL THE CONTRACTOR HAS RECEIVED WRITTEN AND/OR STAMPED APPROVAL (FROM THE GOVERNMENT) OF RELATED SHOP DRAWINGS AND MANUFACTURERS' SPECIFICATION DATA.
21. THE CONTRACTOR IS TO PROVIDE CLOSE OUT DOCUMENTATION UPON COMPLETION OF THE PROJECT TO THE TENANT. COORDINATE FINAL REQUIREMENTS WITH GOVERNMENT. GC TO PROVIDE ELECTRONIC AND HARD COPIES OF AS-BUILTS.
22. THE CONTRACTOR MUST MAINTAIN EMERGENCY EGRESS ACCESS AND ENSURE SECURITY OF THE SPACE AT ALL TIMES.
23. WORK MUST BE COMPLETED DURING TYPICAL OPERATION HOURS EXCEPT FOR SHUT DOWNS AND WORK INVOLVING NOISE OR ODORS AND WORK INVOLVING OTHER OCCUPIED FLOORS AND ADJACENT SPACES. WORK INVOLVING NOISE OR ODORS, AND WORK INVOLVING OTHER OCCUPIED FLOORS AND ADJACENT SPACES MUST BE DONE PRIOR TO 6:00AM AND/OR AFTER 6:00PM OR DURING WEEKENDS, UON. COORDINATION WITH THE
GOVERNMENT IS REQUIRED.
24. COMPLETE SPECIFICATIONS ARE TO BE A PART OF THIS CONSTRUCTION DOCUMENT SUBMITTAL.
25. EXISTING FIRE SEPARATION WALLS AND THEIR RATINGS MUST BE MAINTAINED BETWEEN THE CONSTRUCTION AREA AND OCCUPIED AREAS.
PROVIDE TEMPORARY FIRE BARRIERS AS REQUIRED.
PARTITION TYPE
COLUMN REFERENCE
DETAILS
INTERIOR
ELEVATION
REFERENCE
BUILDING / WALL SECTION
EXTERIOR ELEVATION
REFERENCE
DRAWING TITLE
KEY NOTE
(First number indicates specification division)
WINDOW / LOUVER / GLASS TYPE
ROOM NAME & NUMBER
REVISION
SPOT ELEVATION
DOOR NUMBER
A101
A101
A101
A101
VEW #
SHT #
DRAWING TITLE
SCALE
DRAWING TITLE
BACK REFERENCED
VEW #
SHT
DRAWING TITLE
SCALEREF
A101
ROOM
NAME
9'-0" CEILING HEIGHT A.F.F.
ACT-1 CEILING MATERIAL
1a
W1a
CONCRETE MASONRY
CUT BLOCKING / SHIM
WOOD BLOCKING
RIGID INSULATION
BATT INSULATION
CONCRETE
BRICK
FINISH WOOD / HARD WOOD
SEALANT / CAULKING
ENGINEERED FILL
STEEL
GYPSUM
1. A HAZARDOUS MATERIALS SURVEY ASSESSMENT HAS BEEN CONDUCTED FOR ASBESTOS-CONTAINING MATERIALS (ACM), LEAD-BASED PAINT (LBP) AND OTHER POTENTIALLY REGULATED MATERIALS. REFER TO THE USU-76 REVIEW ROOF DESIGN HAZARDOUS MATERIALS ASSESSMENT REPORT
DATED NOVEMBER 1, 2022.
2. SUSPECT ASBESTOS-CONTAINING MATERIALS (ACM) ARE PRESENT IN THE DESIGNATED RENOVATION AREA. REFER TO THE USU-76 REVIEW ROOF
DESIGN HAZARDOUS MATERIALS ASSESSMENT REPORT DATED NOVEMBER 1, 2022.
3. LEAD-BASED PAINT COATED COMPONENTS ARE NOT PRESENT IN THE DESIGNATED AREA. REFER TO THE USU-76 REVIEW ROOF DESIGN HAZARDOUS
MATERIALS ASSESSMENT REPORT DATED NOVEMBER 1, 2022.
4. IF ASBESTOS ABATEMENT IS REQUIRED, ABATEMENT SHALL BE PERFORMED WITHIN A NEGATIVE PRESSURE ENCLOSURE (NPE) WITH AFFIXED DECONTAMINATION UNIT, USING PROPER ENGINEERING CONTROLS AND WORK PRACTICES IN COMPLIANCE WITH FEDERAL, STATE AND LOCAL REGULATIONS DETAILED IN THE SPECIFICATION SECTION 020850– ASBESTOS ABTEMENT PROCEDURES.
5. LEAD REMEDIATION IS NOT ANTICIPATED DURING THIS RENOVATION. REFER TO THE SPECIFICATION SECTION 020900 – CONTROL OF LEAD-BASED
PAINT FOR LEAD SAFE WORK PRACTICES TO BE FOLLOWED DURING DEMOLTION.
6. IF ADDITIONAL SUSPECT MATERIALS ARE UNCOVERED DURING RENOVATIONS, IN AREAS PREVIOUSLY NOT IDENTIFIED, ALL CONSTRUCTION ACTIVITIES SHALL CEASE AND BULK SAMPLING AND/OR XRF TESTING FOR LBP SHALL BE PERFORMED TO CONFIRM OR REFUTE THE PRESENCE OF
ACM OR LBP.
7. FOR FLOURESCENT LAMP LIGHT FIXTURES AND OTHER REGULATED COMPONENTS THAT CONTAIN PCBs and MERCURY, REFER TO THE
SPECIFICATION SECTION 020890 FOR SMALL PCB ITEMS AND MERCURY LAMPS.
8. HAZARDOUS MATERIAL NOTES ABOVE AND COORDINATING SPECIFICATIONS PROVIDED BY TIDEWATER, INC.
THE GENERAL SCOPE OF WORK INCLUDES, BUT IS NOT LIMITED TO, DEMOLITION OF EXISTING ROOFING, INTERIOR / EXTERIOR RENOVATIONS FOR A ROOF GARDEN ON THE 2ND FLOOR. THE RENOVATION INCLUDES A RAMP, ROOF ACCESS, VEGETATIVE ROOFING SYSTEM WITH WOOD PAVERS, STRUCTURAL
STRENGTHENING, MECHANICAL PLUMBING, FIRE PROTECTION AND ELECTRICAL RELOCATION /
UPGRADES TO SUPPORT THE ROOF GARDEN DESIGN.
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S
TE
M S
C O
M M
A N
D
W A
S H
IN
G
TO
N
N A
V A
L S
U P
P O
R T
A C
T
IV
IT
Y
B E
T H
E S
D A
M
A R
Y L
A N
D
AS NOTED
P U
B L
IC
W
O R
K S
D E
P A
R T
M E
N T
B
E T
H E
S D
A
3200 LANGSTON BOULEVARD, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 9635,
EXPIRATION DATE 8/15/23.
/2
/2
:1
:2
P
M
G-002
B u ild in g
E
R o o f G a rd e n
G E
N E
R A
L N
O
TE
S , A
B B
R E
V
IA
TI
O
N S
A N
D S
YM
B
O
LS
BB
13148359
MJB CBM
FINAL DESIGN SUBMISSION
1698751
B E
T H
E S
D A
, M D
U N
IF
O
R M
E D
S E
R V
IC
E
S U
N
IV
E R
S
IT
Y O
F T
H E
H E
A
LT
H S
C
IE
N C
E S
G -0
F in a l D e s ig n S u b m is s io n
/2
/2
/2
8/
F in al
D es ig n
S ub m is si on
GENERAL NOTES: MATERIAL SYMBOLS: DRAWING SYMBOLS:
ABBREVIATIONS:
SCOPE OF WORK:
HAZARDOUS MATERIALS:
AB ANCHOR BOLT
ABV ABOVE
ACC ACCESS
ACOUS ACOUSTICAL
ACP ACOUSTICAL PANEL CEILING
AD AREA DRAIN
ADJ ADJUSTABLE
AFF ABOVE FINISH FLOOR
AHU AIR HANDLING UNIT
ALT ALTERNATE
ALUM ALUMINUM
ANC ANCHORS
APPROX APPROXIMATE
ARCH ARCHITECT
AUTO AUTOMATIC
AVG AVERAGE
B BATHROOM
BD BEAD
BIT BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BO BY OWNER
BOT BOTTOM
BRD BOARD
BRKT BRACKET
BSL BUILDING SETBACK LINE
BSMT BASEMENT
BU BUILT UP
CAB CABINET
CEM CEMENT
CF CUBIC FOOT (FEET)
CI CAST IRON
CJ CONTROL JOINT
CL, CLO CLOSET
CLG CEILING
CLL CONTRACT LIMIT LINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
CNR CORNER
CO CLEAN OUT
COL COLUMN
CONC CONCRETE
CONST CONSTRUCTION
CONT CONTINUOUS
CPT CARPET
CS COURSES
CT CERAMIC TILE
CTR CENTER
CTSK COUNTER SUNK
DBL DOUBLE
DEPT DEPARTMENT
DET DETAIL
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DIA DIAMETER
DIFF DIFFUSER
DIM DIMENSION
DISP DISPENSER
DIV DIVISION (DIVIDED)
DN DOWN
DR DOOR
DS DOWN SPOUT
DW DISHWASHER
DWGS DRAWINGS
DWR DRAWER
E EAST
EA EACH
EJ EXPANSION JOINT
EL ELEVATION
ELEC ELECTRICAL
ELEV ELEVATION
ENCL ENCLOSURE
ENT ENTRANCE
EQ EQUAL
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EX EXISTING
EXP EXPANSION
FD FLOOR DRAIN
FE(C) FIRE EXTINGUISHER
FF FINISHED FLOOR
FF&E FIXTURE FURNITURE & EQUIPMENT
FG FINISHED GRADE
FIN FINISH
FL FLOORING
FLEX FLEXIBLE
FLSG FLASHING
FLUOR FLUORESCENT
FR FRAME
FRPF FIRE PROOFING
FRT FIRE RETARDANT TREATED
FT FOOT (FEET)
FTG FOOTING
FUR FURRING
FVC FIVE VALVE CABINET
GA GAUGE
GALV GALVANIZED
GB GYPSUM BOARD
GC GENERAL CONTRACTOR
GL GLASS
GR GRADE
GWB GYPSUM WALLBOARD
HB HOSE BIB
HC HOLLOW CORE
HD HEAVY DUTY
HDWD HARDWOOD
HDWR HARDWARE
HM HOLLOW METAL
HORIZ HORIZONTAL
HP HIGH POINT
HT HEIGHT
HVAC HEATING, VENT, AIR
CONDITIONING
ID INSIDE DIAMETER
IGU INSULATED GLASS UNIT
INST INSTALLATION
INSUL INSULATION
INT INTERIOR
JAN JANITOR
JBE JOIST BEARING ELEVATION
JST JOIST
JT JOINT
KD KNOCK DOWN
KIT KITCHEN
KO KNOCK OUT
LAM LAMINATED
LAV LAVATORY
LIN LINEAR
LP LOWPOINT
LT LIGHT
LW LIGHTWEIGHT
MACH MACHINE
MAINT MAINTENANCE
MATL MATERIAL
MAX MAXIMUM
MB MARKER BOARD
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MEMB MEMBRANE
MEP MECHANICAL, ELECTRICAL,
PLUMBING
MET, MTL METAL
MEZZ MEZZANINE
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MLDG MOLDING
MO MASONRY OPENING
MOD MODIFIED
MTD MOUNTED
N, NO NORTH
NIC NOT IN CONTRACT
NRC NOISE REDUCTION COEFFICIENT
NTS NOT TO SCALE
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFCI OWNER FURNISHED /
CONTRACTOR INSTALLED
OFF OFFICE
OH OVERHEAD
OP HD OPPOSITE HAND
OPG OPENING
OPP OPPOSITE
P-LAM PLASTIC LAMINATE
PAR PARTIAL
PART PARTITION
PED PEDESTRIAN
PLX PLEXIGLASS
PLYWD PLYWOOD
PNL PANEL
POL POLISH (POLISHED)
PR PAIR
PREFAB PREFABRICATED
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PAINT
PTD PAINTED
QT QUARRY TILE
QTY QUANTITY
RAD RADIUS
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REF REFERENCE
REF'G REFRIGERATOR
REINF REINFORCED (ING)
REQ REQUIRED
RES RESILIENT
REV REVISE (REVISION)
RO ROUGH OPENING
RTU ROOF TOP UNIT
SC SOLID CORE
SCHED SCHEDULE
SCHWD SOLID CORE WOOD DOOR
SECT SECTION
SF SQUARE FOOT (FEET)
SFPS STRETCHED FABRIC PNL. SYS
SHR SHOWER
SHT SHEET
SIM SIMILAR
SL SLIDING
SQ SQUARE
SS, S.STL. STAINLESS STEEL
SSK SERVICE SINK
STA STATION
STC SOUND TRANSMISSION CLASS
STD STANDARD
STL STEEL
STN STAIN
STOR STORAGE
STRUCT STRUCTURAL
SUSP SUSPENDED
SW SWITCH
SYS SYSTEM
T&G TONGUE & GROOVE
T.O.STL TOP OF STEEL
TB TACK BOARD
TBR TO BE REMOVED
TEL TELEPHONE
TEMP TEMPERED
THK THICK
THR THRESHOLD
TLT TOILET
TO TOP OF
TOS TOP OF SLAB
TV TELEVISION
TYP TYPICAL
UL UNDERWRITER'S LABORATORIES
UNF UNFINISHED
UNO UNLESS NOTIFIED (NOTED)
OTHERWISE
UR URINAL
UTL UTILITY
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VIF VERIFY IN FIELD
W WEST
W/ WITH
W/O WITH OUT
WD WOOD
WH WATER HEATER
WP WATERPROOFING
WR WATER RESISTANT
WT WEIGHT
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
F
E
E
G
G
OFFICE
E1061
OFFICE
E1060
OFFICE
E1059
CORRIDOR
E1907
OFFICE
E1049
OFFICE
E1048
OFFICE
E1047
OFFICE
E1046
OFFICE
E1045
OFFICE
E1044
CORRIDOR
E1908
ELEC
E1006
OFFICE
E1040
STORAGE
E1042
F
F
E
E
OFFICE
E2041
OFFICE
E2040
CORRIDOR
E2908
OFFICE
E2043
OFFICE
E2044
OFFICE
E2051
OFFICE
E2050
OFFICE
E2045
LEGEND (PHASING)
PHASE 1 - CONSTRUCTION
PHASE 2 - CONSTRUCTION
PHASE 3 - CONSTRUCTION
GENERAL NOTES (PHASING)
1. MAINTAIN CLEAR AND SAFE EGRESS FOR ALL OCCUPIED
SPACES AND ADJACENT AREAS DURING PHASED
CONSTRUCTION.
2. WORK IN GROUND FLOOR DETAIL 2/M-101 AND WORK ON
FIRST FLOOR NORTH OF COLUMN LINE 2 SHALL OCCUR
DURING PHASE 1. WORK ON FIRST FLOOR SOUTH OF
COLUMN LINE 2 SHALL OCCUR DURING PHASE 2. WORK ON
ROOF AND ON SECOND FLOOR SHALL OCCUR DURING
PHASE 3.
3. WORK ON THE GROUND FLOOR COORIDOR BETWEEN
COLUMNS A - E AND 3 - 4 SHALL BE COMPLETED DURING
WEEKEND HOURS. EXISTING CEILING SYSTEM, GRID,
LIGHTS AND ALL DEVICES TO REMAIN.
F
F
E
E
D
D
C
C
B
B
A
A
G
G
G-003
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S
TE
M S
C O
M M
A N
D
W A
S H
IN
G
TO
N
N A
V A
L S
U P
P O
R T
A C
T
IV
IT
Y
B E
T H
E S
D A
M
A R
Y L
A N
D
AS NOTED
P U
B L
IC
W
O R
K S
D E
P A
R T
M E
N T
B
E T
H E
S D
A
3200 LANGSTON BOULEVARD, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ARCHITECT
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 9635,
EXPIRATION DATE 8/15/23.
/2
/2
:1
:2
P
M
G-003
B u ild in g
E
R o o f G a rd e n
P H
A S
IN
G
P
LA
N S
BB
13148360
MJB CBM
FINAL DESIGN SUBMISSION
1698751
B E
T H
E S
D A
, M D
U N
IF
O
R M
E D
S E
R V
IC
E
S U
N
IV
E R
S
IT
Y O
F T
H E
H E
A
LT
H S
C
IE
N C
E S
G -0
F in a l D e s ig n S u b m is s io n
/2
/2
/2
8/
F in al
D es ig n
S ub m is si on
SCALE: 1/8" = 1'-0"G-003
1 LEVEL 1 - ENLARGED PHASING PLAN
SCALE: 1/8" = 1'-0"G-003
2 LEVEL 2 - PHASING PLAN
TRUE
NORTH
PLAN
NORTH
0 4' 8' 16' 24'
1/8" = 1'-0"
SCALE: 1/16" = 1'-0"G-003
3 LEVEL 1 - OVERALL PHASING
0 8' 16' 32' 48'
1/16" = 1'-0"
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
FI
LE
N
AM
E:
OU
RE
F:
PL
OT
D
AT
E:
6/2
0/2
3 1 1:1
0:0 9 A
M
1.4
1.4
3 G I00
1.D W
G 1 2 3 4 5
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
W
AS
HI
NG
TO
N N
AV
AL
S U
PP
O
R T
AC
TI
VI
TY
B
ET
H
ES
D A, M
AR
YL
AN
D
B ui ld in g
E R oo f G ar de n
FINAL DESIGN
SUBMISSION
1698751
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
BE
TH
ES
DA
, M D
UN
IF
OR
ME
D
SE
RV
IC
ES
U
NI
VE
RS
IT
Y
OF
T
HE
H
EA
LT
H
SC
IE
NC
ES
PU
BL
IC
W
O R
KS
D
EP
AR
TM
EN
T, B
ET
H
ES
D
A
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
/28
/20
FI
NA
L D
ES
IG
N
SU
BM
IS
SI
ON
7900 Westpark Dr. | Suite A405 | McLean, VA 22102
(703) 556-8820 | www.summerconsultants.com
SUMMER
CONSULTANTS
I N C O R P O R A T E D
BU
ILD
IN
G
CO
DE
S
UM
MA
RY
EA JL AP
AS NOTED
13148361
GI001
1. UNIFIED FACILITIES CRITERIA (UFC)
2022 UFC 1-200-01 DOD BUILDING CODE
2. INTERNATIONAL CODE COUNCIL (ICC)
2021 INTERNATIONAL BUILDING CODE (IBC)
3. NATIONAL FIRE PROTECTION ASSOCIATION (NFPA)
2022 NFPA 13 STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS
2023 NFPA 70 NATIONAL ELECTRICAL CODE
2022 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE
2021 NFPA 101 LIFE SAFETY CODE
APPLICABLE CODES
CONSTRUCTION TYPE
REQUIRED - PER IBC SECTION 601, ALL BUILDINGS MUST BE ASSIGNED A TYPE OF CONSTRUCTION.
PROVIDED - THE FACILITY MOST CLOSELY RESEMBLES CONSTRUCTION TYPE IB IN ACCORDANCE WITH IBC
CHAPTER 6.
OCCUPANCY USE
REQUIRED - NFPA 101 SECTION 6.1.14 ALLOWS MULTIPLE OCCUPANCIES TO BE TREATED AS MIXED USE
NON-SEPARATED WHERE INCIDENTAL TO ANOTHER OCCUPANCY.
PROVIDED - THE FACILITY WILL BE TREATED AS A MIXED USE NON-SEPARATED OCCUPANCY TYPE.
OCCUPANCY CLASSIFICATIONS
EGRESS CAPACITY
THE FACILITY EGRESS CAPACITY FACTORS ARE:
- 0.2 INCHES/PERSON FOR LEVEL COMPONENTS.
- 0.3 INCHES/PERSON FOR STAIR COMPONENTS.
EXISTING FACILITY
IN ACCORDANCE WITH IBC CHAPTER 3 AND NFPA 101 CHAPTER 6.
BUILDING AREA
OCCUPANT LOAD
FIRE PROTECTION SYSTEMS
REQUIRED - UFC REQUIRES FACILITIES TO BE PROTECTED WITH AN AUTOMATIC WET-PIPE SPRINKLER
SYSTEM IN COMPLIANCE WITH NFPA 13 AND UFC 3-600-01.
PROVIDED - THE BUILDING IS PROTECTED WITH AN AUTOMATIC WET-PIPE SPRINKLER SYSTEM IN
COMPLIANCE WITH NFPA 13 AND UFC 3-600-01.
REQUIRED - UFC REQUIRES A FIRE ALARM SYSTEM IN COMPLIANCE WITH NFPA 72 AND UFC 3-600-01 AND A
MASS NOTIFICATION SYSTEM IN COMPLIANCE WITH UFC 4-021-01.
PROVIDED - THE BUILDING HAS A COMBINED ADDRESSABLE FIRE ALARM AND MASS NOTIFICATION SYSTEM
INSTALLED IN COMPLIANCE WITH NFPA 72, UFC 3-600-01, AND UFC 4-021-01.
STORIES AND HEIGHT
THE ALLOWABLE AREA PER FLOOR IS BASED ON IBC SECTION 506.
ALLOWABLE AREA PER FLOOR - 144,000 SQUARE FEET
FIRST FLOOR AREA - 13,144 SQUARE FEET
SECOND FLOOR AREA - 13,144 SQUARE FEET
THE ALLOWABLE BUILDING STORIES AND HEIGHT ARE BASED ON IBC CHAPTER 504.
ALLOWABLE BUILDING STORIES AND HEIGHT ABOVE GRADE - 12 STORIES | 180 FEET
ACTUAL BUILDING STORIES AND HEIGHT ABOVE GRADE - 2 STORIES | 43 FEET
OCCUPANCY
CLASSIFICATION OCCUPANCY USE GROUP
OCCUPANT LOAD
FACTOR COMMENTS
COMPONENT REQUIRED FIRE RESISTANCE
PRIMARY STRUCTURAL FRAME 2 HOUR
BEARING WALLS 2 HOUR
NONBEARING WALLS AND BY OTHER CRITERIA
FLOOR CONSTRUCTION AND SECONDARY MEMBERS 2 HOUR
ROOF CONSTRUCTION AND SECONDARY MEMBERS 1 HOUR
INTERIOR FINISH
OCCUPANCY
MAX ALLOWABLE TRAVEL
DISTANCE
MAX ALLOWABLE COMMON
PATH OF TRAVEL
MAX ALLOWABLE DEAD
END
STRUCTURAL FIRE RESISTANCE RATING
OCCUPANCY MULTIPLE FLOOR SPRINKLERED, ALLOWABLE AREA
STORAGE (S-1) 144,000
MEANS OF EGRESS
REQUIRED INTERIOR FINISH - NFPA 101 CHAPTER 10
WALLS AND CEILINGS
1. BUSINESS - CLASS C MINIMUM
FLOORS
1. BUSINESS - CLASS II
EXTERIOR WALL FIRE RESISTANCE RATING
REQUIRED - PER IBC TABLE 705.5, EXTERIOR WALLS ARE REQUIRED TO HAVE A 1-HOUR FIRE RATING WHEN LESS THAN 30 FEET
FROM ADJACENT BUILDINGS.
PROVIDED - THE SOUTH EXTERIOR WALL IS LESS THAN 30 FEET FROM BUILDING 73 D AND HAS A 1-HOUR FIRE RATING. ALL OTHER EXTERIOR WALLS ARE MORE THAN 30 FEET FROM THE CLOSEST BUILDING AND HAVE NO FIRE RATING.
STORAGE 400 FEET 100 FEET 100 FEET
BUSINESS 300 FEET 100 FEET 50 FEET
BUSINESS LESS CONCENTRATED 150 SF/PERSON
GROSS
REQUIRED - THE BUILDING WILL MEET THE CRITERIA FOR NFPA 101 CHAPTER 43 FOR MODIFICATION WORK.
PROVIDED - ALL NEW WORK AND MATERIALS WILL MEET NEW CONSTRUCTION CRITERIA INCLUDING BUT NOT
LIMITED TO IBC AND NFPA 101 CRITERIA. THE BUILDING WILL REMAIN OCCUPIED OUTSIDE AREA
OF WORK. LIFE SAFETY SYSTEMS WILL REMAIN ACTIVE THROUGHOUT CONSTRUCTION.
1. BUSINESS / B
2. STORAGE / S-1
3. STORAGE / S-2
4. ASSEMBLY / A-3 - ONLY PRESENT ON GROUND FLOOR
REQUIRED OCCUPANCY SEPARATION - 0 HOUR
PROVIDED OCCUPANCY SEPARATION - 0 HOUR
BUILDING CODE AND LIFE SAFETY NARRATIVE
PER IBC TABLE 601, REQUIRED AND PROVIDED FIRE RESISTANCE TABLE.
REQUIRED - EGRESS CAPACITY MUST BE ABLE TO SUPPORT OCCUPANT LOAD.
PROVIDED - EGRESS CAPACITY IS ADEQUATE TO SUPPORT OCCUPANT LOAD.
SEE LIFE SAFETY PLANS FOR EGRESS CAPACITY PER EXIT.
REQUIRED ARRANGEMENT OF EGRESS
REQUIRED - TRAVEL DISTANCES MUST BE LESS THAN MOST STRICT REQUIREMENT (BUSINESS - ON 1ST
AND 2ND FLOOR).
PROVIDED - TRAVEL DISTANCES ARE LESS THAN MOST STRICT REQUIREMENT (BUSINESS - ON 1ST AND
2ND FLOOR).
SEE LIFE SAFETY PLANS FOR LOCATIONS OF ACTUAL ARRANGEMENT OF EGRESS.
REQUIRED: EXIT REMOTENESS SHALL AT MINIMUM BE ONE THIRD OF THE LENGTH OF BUILDING DIAGONAL.
PROVIDED: EXITS ARE LOCATED MORE THAN 13 OF THE BUILDINGS DIAGONAL APART.
REQUIRED # OF EXITS PER FLOOR - 2
PROVIDED # OF EXITS PER FLOOR - 2
PROVIDED INTERIOR FINISH
WALLS AND CEILINGS - CLASS C
FLOORS - CLASS II
THE PROJECT ENTAILS THE ADDITION OF A ROOF GARDEN ON THE SECOND FLOOR OF USUHU BUILDING 76E. THE STRUCTURE UNDERNEATH THE PLANNED ROOF GARDEN WILL BE MODIFIED TO SUPPORT THE ADDITIONAL LOAD.
PART OF THE PROJECT SCOPE OF WORK INCLUDES ALTERING ROOM E2042 ON THE SECOND FLOOR TO CREATE A
RAMP OUT TO THE ROOF GARDEN.
AREA
OCCUPANT
LOAD
11,720 SF 79
• 2021 INTERNATIONAL EXISTING BUILDING CODE (IEBC)
PROVIDED FIRE RESISTANCE
2 HOUR
2 HOUR
BY OTHER CRITERIA
2 HOUR
1 HOUR
FIRST FLOOR
EXTERIOR
INTERIOR 0 HOUR 0 HOURPARTITIONS
TOTAL
EXTERIOR
INTERIOR 2 HOUR 2 HOUR
STORAGE IN NON STORAGE 500 SF/PERSON 964 SF 2
2021 NFPA 1 FIRE CODE
2022 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS
• 2021 UFC 3-600-01 CHANGE 6 FIRE PROTECTION ENGINEERING FOR FACILITIES
MAJOR PROJECT
REQUIRED - PER UFC 3-600-01 SECTION 2-1.20, THE WORK FALLS UNDER MAJOR PROJECT REQUIREMENTS.
PROVIDED - THE MODIFICATION WILL MEET MAJOR PROJECT REQUIREMENTS.
13,144 SF 112
BUSINESS TABLES AND CHAIRS 15 SF/PERSON 460 SF 31
SECOND FLOOR
709 SF 48
BUSINESS LESS CONCENTRATED 150 SF/PERSON 11,811 SF 79
13,144 SF 156TOTAL
BUSINESS TABLES AND CHAIRS 15 SF/PERSON
624 SF 2STORAGE IN NON-STORAGE 500 SF/PERSON
GROSS
ASSEMBLY 250 FEET 75 FEET 20 FEET
BUSINESS COLLABORATION < 450 SF 30 SF/PERSON 785 SF 27
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 41681,
EXPIRATION DATE 2/28/2024.
06/28/2023
FE
N
8'0 16' 1/8"=1'-0"
FIRST FLOOR1
DCBA
SPACE DIAGONAL = 172 FT
REQUIRED EXIT REMOTENESS = 58 FT
EXIT REMOTENESS = 132 FT
56 0.3
OFFICES
OFFICES
OFFICES
OPEN OFFICES
MECH. ROOM
ELEC. ROOM
STORAGE
BOOK
ROOM
S
500 SF/P
S
500 SF/P B
150 SF/P
S
500 SF/P
S
500 SF/P
S
500 SF/P
S
500 SF/P
S
500 SF/P
TRAVEL DISTANCE = 118 FT
COMMON PATH OF TRAVEL = 28 FT
56 0.2
B
15 SF/P
STORAGE
CONFERENCE
ROOM
S
500 SF/P
FILES
FE
FE
FE
FI
LE
N
RE
F:
PL
OT
D
AT
E:
6/2
0/2
3 1 1:1
0:1 7 A
M
1.4
1.4
3 G I10
1.D W
G 1 2 3 4 5
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
W
AS
HI
NG
TO
N N
AV
AL
S U
PP
O
R T
AC
TI
VI
TY
B
ET
H
ES
D A, M
AR
YL
AN
D
B ui ld in g
E R oo f G ar de n
FINAL DESIGN
SUBMISSION
1698751
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
BE
TH
ES
DA
, M D
UN
IF
OR
ME
D
SE
RV
IC
ES
U
NI
VE
RS
IT
Y
OF
T
HE
H
EA
LT
H
SC
IE
NC
ES
PU
BL
IC
W
O R
KS
D
EP
AR
TM
EN
T, B
ET
H
ES
D
A
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
/28
/20
FI
NA
L D
ES
IG
N
SU
BM
IS
SI
ON
7900 Westpark Dr. | Suite A405 | McLean, VA 22102
(703) 556-8820 | www.summerconsultants.com
SUMMER
CONSULTANTS
I N C O R P O R A T E D
FI
RS
T
FL
OO
R
EA JL AP
AS NOTED
13148362
GI101
LIFE SAFETY LEGEND
A
OCCUPANCY USE
OCCUPANT LOAD
FACTOR (OLF)
SQUARE FEET/
PERSON15 SF/P
EGRESS WIDTH
CAPACITY FACTOR
MAXIMUM NUMBER
OF OCCUPANTS
EGRESS WIDTH
CAN SUPPORT
DEAD END
COMMON PATH OF
TRAVEL
MAXIMUM TRAVEL
DISTANCE
NUMBER OF OCCUPANTS
USING EXIT STAIR
2 HOUR FIRE BARRIER
200 0.3
1 HOUR FIRE BARRIER
OCCUPANT LOAD - 1ST FLOOR
OCCUPANCY
CLASSIFICATION OCCUPANCY USE GROUP
OCCUPANT LOAD
FACTOR AREA
OCCUPANT
LOAD
460 SF 31
BUSINESS LESS CONCENTRATED 150 SF/PERSON 11,720 SF 79
964 SF 2STORAGE IN NON-STORAGE 500 SF/PERSON
13,144 SF 112TOTAL
BUSINESS TABLES AND CHAIRS 15 SF/PERSON
EGRESS WIDTH
CAPACITY FACTOR
MAXIMUM NUMBER
OF OCCUPANTS
EGRESS WIDTH
CAN SUPPORT
NUMBER OF OCCUPANTS
USING EXIT DOOR
200 0.3
USE AND OCCUPANT LOAD FACTORS
BUSINESS USE - TABLES AND CHAIRS
STORAGE USE - IN NON-STORAGE
BUSINESS USE - LESS CONCENTRATED
PORTABLE FIRE
EXTINGUISHERFE
EXIT SIGN
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 41681,
FE
N
8'0 16' 1/8"=1'-0"
SECOND FLOOR1
DCBA
SPACE DIAGONAL = 172 FT
REQUIRED EXIT REMOTENESS = 58 FT
EXIT REMOTENESS = 132 FT
MECH. ROOM
ELEC. ROOM
STORAGE
CONFERENCE
ROOM
STORAGE
STORAGE STORAGE
ELEC. ROOM
OPEN OFFICE
OFFICES
OFFICES
OFFICES 160
78 0.3
78 0.3
B
15 SF/P
B
150 SF/P
TRAVEL DISTANCE = 100 FT
B
30 SF/P
S
500 SF/P
S
500 SF/P
S
500 SF/P
S
500 SF/P
S
500 SF/P
TR
AV
EL
D
IS
TA
NC
E
7 F T
CO
MM
ON
P
AT
H
OF
T
RA
VE
L =
F
TCONFERENCE
ROOM
CONFERENCE
ROOM
FE
FE
FE
FI
LE
N
RE
F:
PL
OT
D
AT
E:
6/2
0/2
3 1 1:1
0:2 4 A
M
1.4
1.4
3 G I10
2.D W
G 1 2 3 4 5
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D
EP
AR
TM
EN
T
O F
TH
E
N
AV
Y N
AV
AL
F
AC
IL
IT
IE
S
EN
G
IN
EE
R
IN
G S
YS
TE
M S
C O
M M
AN
D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
NA
VA
L
FA
CI
LI
TI
ES
E
NG
IN
EE
RI
NG
S
YS
TE
M
S
CO
M M
AN
D
W
AS
HI
NG
TO
N N
AV
AL
S U
PP
O
R T
AC
TI
VI
TY
B
ET
H
ES
D A, M
AR
YL
AN
D
B ui ld in g
E R oo f G ar de n
FINAL DESIGN
SUBMISSION
1698751
SY
M
DE
SC
RI
PT
IO
N
DA
TE
AP
PR
BE
TH
ES
DA
, M D
UN
IF
OR
ME
D
SE
RV
IC
ES
U
NI
VE
RS
IT
Y
OF
T
HE
H
EA
LT
H
SC
IE
NC
ES
PU
BL
IC
W
O R
KS
D
EP
AR
TM
EN
T, B
ET
H
ES
D
A
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
/28
/20
FI
NA
L D
ES
IG
N
SU
BM
IS
SI
ON
7900 Westpark Dr. | Suite A405 | McLean, VA 22102
(703) 556-8820 | www.summerconsultants.com
SUMMER
CONSULTANTS
I N C O R P O R A T E D
SE
CO
ND
F
LO
OR
EA JL AP
AS NOTED
13148363
GI102
LIFE SAFETY LEGEND
A
OCCUPANCY USE
OCCUPANT LOAD
FACTOR (OLF)
SQUARE FEET/
PERSON15 SF/P
EGRESS WIDTH
CAPACITY FACTOR
MAXIMUM NUMBER
OF OCCUPANTS
EGRESS WIDTH
CAN SUPPORT
DEAD END
COMMON PATH OF
TRAVEL
MAXIMUM TRAVEL
DISTANCE
NUMBER OF OCCUPANTS
USING EXIT STAIR
2 HOUR FIRE BARRIER
NOTES
1. PROVIDE POSTED SIGNAGE OF 49 MAXIMUM ALLOWABLE OCCUPANTS.
200 0.3
1 HOUR FIRE BARRIER
USE AND OCCUPANT LOAD FACTORS
BUSINESS USE - LESS CONCENTRATED
OCCUPANT LOAD - 2ND FLOOR
OCCUPANCY
CLASSIFICATION OCCUPANCY USE GROUP
OCCUPANT LOAD
FACTOR AREA
OCCUPANT
LOAD
709 SF 48
BUSINESS LESS CONCENTRATED 150 SF/PERSON 11,811 SF 79
13,144 SF 156TOTAL
BUSINESS TABLES AND CHAIRS 15 SF/PERSON
BUSINESS USE - TABLES AND CHAIRS
624 SF 2STORAGE IN NON-STORAGE 500 SF/PERSON
785 SF 27BUSINESS COLLABORATION < 450 SF 30 SF/PERSON
STORAGE USE - IN NON-STORAGE
BUSINESS USE - LESS CONCENTRATED
PORTABLE FIRE
EXTINGUISHERFE
EXIT SIGN
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 41681,
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 41681,
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 41681,
DESIGN NOTES
I. CODES AND STANDARDS
A. WORK IN ACCORDANCE WITH REQUIREMENTS OF THE UFC 1-200-01 DOD BUILDING CODE,
UFC 3-301-01 STRUCTURAL ENGINEERING, AND THE INTERNATIONAL BUILDING CODE, 2018.
B. USE THE CURRENT VERSTION OF ALL CODES, REFERENCES AND STANDARDS REFERRED
UNLESS A DIFFERENT VERSION IS LISTED IN THE BUILDING CODE.
II. DESIGN AND LOADING CRITERIA
A. SNOW LOAD
1. GROUND SNOW LOAD: (PG) = 25.0 PSF
2. SNOW EXPOSURE FACTOR (CE): = 1.0
3. IMPORTANCE FACTOR (I): = 1.0
4. THERMAL FACTOR (CT): = 1.0
5. FLAT ROOF SNOW LOAD (PF): = 20 PSF
B. SEISMIC LOAD
1. RISK CATEGORY: = II
2. SEISMIC IMPORTANCE FACTOR (I): = 1.0
3. MAPPED SPECTRAL RESPONSE: SS = 0.134, S1= 0.043
4. SPECTRAL RESPONSE COEFF SDS = 0.116, SD1= 0.043
5. SITE CLASSIFICATION: = C
6. SEISMIC DESIGN CATEGORY = A
C. WIND LOAD
1. ULTIMATE WIND SPEED: = 112 MPH
2. RISK CATEGORY: = II
3. EXPOSURE: = B
4. INTERNAL PRESSURE COEFF: = +/- 0.18
5. COMPONENT AND CLADDING:
FOR PARAPET (GURADRAIL) = 89 PSF MAX [ULTIMATE]
ROOFTOP:
TRELLIS = 40.5 PSF [ULTIMATE]
UPLIFT ON ROOF:
ZONE 1: = 40.1 PSF MAX [ULTIMATE]
ZONE 2: = 52.9 PSF MAX [ULTIMATE]
ZONE 3: = 72.1 PSF MAX [ULTIMATE]
OTHER DESIGN PRESSURES MAYBE USED IF SIGNED & SEALED CALCULATIONS ARE
SUBMITTED FOR REVIEW
D. DESIGN MINIMUM LIVE LOADS:
1. ROOF PAVER AREAS: = 50 PSF
2. GREEN ROOF AREAS: = 30 PSF [LIVE LOAD REDUCTION]
3. REFER TO UNIFORM LOADING DIAGRAM ON SHEET S101
E. EXISTING LIVE LOAD CAPACITIES
1. THE EXISTING ALLOWABLE LIVE LOAD CAPACITIES PER EXISTING DRAWINGS ARE AS
FOLLOWS:
i. 1ST & 2ND FLOOR OFFICES = 100 PSF [INCLUDES 20 PSF FOR PARTITIONS]
ii. 1ST FLOOR ROOF & MAIN ROOF = 30 PSF
2. PROVIDE TEMPORARY SHORING AND/OR BRACING WHEREVER THE LOADING FROM THE
CONTRACTOR’S WORK EXCEEDS THE ALLOWABLE LOAD CAPACITIES OF THE EXISTING
STRUCTURE.
III. WOOD AND TIMBER FRAMING MATERIALS
A. PROVIDE LUMBER AND TIMBER DESIGN, FABRICATION AND ERECTION IN ACCORDANCE
WITH:
1. "NATIONAL DESIGN SPECIFICATIONS FOR WOOD CONSTRUCTION."
2. "AMERICAN SOFTWOOD LUMBER STANDARDS."
3. GRADES FOR JOISTS: REDWOOD #1, WITH MAXIMUM MOISTURE CONTENT 19%.
SAWN LUMBER MINIMUM MEMBER PROPERTIES:
1. JOISTS
a) FLEXURE: FB = 750 PSI
b) SHEAR: FV = 160 PSI
c) MODULUS OF ELASTICITY E = 1,100,000 PSI
B. FOR TREATED LUMBER COMPLY WITH REQUIREMENTS OF THE "WOOD-PRESERVERS'
ASSOCIATION."
1. TIMBER & LUMBER: AWPA C1
IV. STRUCTURAL STEEL
A. PROVIDE STRUCTURAL STEEL THAT IS DESIGNED, FABRICATED AND ERECTED IN
ACCORDANCE WITH "SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS AND THE
"MANUAL OF STEEL CONSTRUCTION" FIFTEENTH EDITION.
B. STRUCTURAL STEEL:
1. STRUCTURAL "W" & "T" SHAPES: ASTM A-992 FY = 50,000 PSI
2. BALANCE OF STEEL SHAPES & PLATES: ASTM A-36 FY = 36,000 PSI
3. HOLLOW SECTIONS (HSS) SQUARE & RECTANGULAR ASTM A-500B FY = 46,000 PSI
4. HIGH STRENGTH BOLTS: ASTM F3125, GR A-325 CONN
TYPE-N
5. GALVANIZING (HOT-DIP): ASTM A-123
C. PROVIDE CONNECTIONS IN ACCORDANCE WITH "BEAM CONNECTIONS" AS DESCRIBED IN
THE AISC MANUAL. CONNECTIONS SHALL BE MADE USING HIGH STRENGTH BOLTS IN
ACCORDANCE WITH ASTM A-325. SHOP CONNECTIONS MAY BE WELDED IN LIEU OF
BOLTING. WHERE REACTION NOT GIVEN ON PLANS AND SECTIONS, PROVIDE CONNECTIONS
DESIGNED FOR A MINIMUM OF 60% FOR FILLER BEAMS AND 70 % FOR GIRDERS OF MAXIMUM
BEAM CARRYING CAPACITY UNDER UNIFORM LOAD FOR SPAN SHOWN. SEE PLANS AND
SECTIONS FOR OTHER THAN STANDARD CONNECTIONS. PROVIDE MINIMUM NUMBER OF
BOLTS IN EACH OF BEAM WEB CONNECTION AND TO SUPPORTING MEMBER AS FOLLOWS:
(SECTIONS; MC, C, S, M & WF)
D = 4" - 6": 2 BOLTS HORIZONTAL
D = 8" - 10": 2 BOLTS VERTICAL
BOLT SPACING SHALL BE 3" O/C.
D. ALTERNATE CONNECTIONS TO THOSE SHOWN ON PLANS AND DETAILS WILL BE ALLOWED
ONLY WITH THE APPROVAL OF THE CONTRACTING OFFICER. IF SUCH APPROVAL IS
GRANTED FOR ANY CONNECTIONS NOT IN ACCORDANCE WITH CONTRACT DOCUMENTS
(FABRICATOR'S REDESIGN), THEN SUBMIT SHOP DRAWING FOR ALTERNATE CONNECTIONS
UNDER THE SEAL OF LICENSURE OF THE FABRICATOR'S ENGINEER FOR THE LOCAL
JURISDICTION.
E. PROVIDE A-325 BOLTS TIGHTENED TO THE "SNUG TIGHT" CONDITION DEFINED AS THE
TIGHTNESS ATTAINED BY A FEW IMPACTS OF AN IMPACT WRENCH OR THE FULL EFFORT OF
A MAN USING AN ORDINARY SPUD WRENCH UNLESS OTHERWISE NOTED. ALL THE PLIES OF
THE CONNECTED MATERIAL MUST BE INTO FIRM CONTACT TO CONFIRM THE SNUG TIGHT
CONDITION.
F. PROVIDE WELDING ACCORDING TO THE REQUIREMENTS OF THE "STRUCTURAL WELDING
CODE" AWS D1.1-08. USE 70 KSI LOW-HYDROGEN ELECTRODES.
G. UNLESS GALVANIZED OR TO RECEIVE SPRAY-APPLIED FIREPROOFING, PROVIDE A
MINIMUMN OF ONE SHOP COAT AND ONE FIELD TOUCH-UP COAT OF RUST-INHIBITING PAINT
AFTER ERECTION FOR STRUCTURAL STEEL.
H. DO NOT FABRICATE STRUCTURAL STEEL PRIOR TO APROVAL OF SHOP DRAWINGS.
I. PROVIDE STRUCTURAL STEEL THAT IS HOT DIPPED GALVANIZED TO ASTM A123 GRADE Z350
WITH TOUCH UP ON ALL DAMAGED AREAS, INCLUDING FIELD WELDS AT ALL EXTERIOR
EXPOSED (INCLUDING IN EXTERIOR WALL WYTHE’S) SHAPES, PLATES AND BOLTS.
J. PROVIDE STRUCTURAL STEEL SHOP DRAWINGS THAT HAVE BEEN PREPARED UNDER THE
SUPERVISION OF A REGISTERED PROFESSIONAL ENGINEER REGISTERED IN PROJECT
JURISDICTION. INCLUDE DETAILS FOR APPLICATION AND ASSEMBLY OF ALL STRUCTURAL
MEMBERS. INCLUDE DETAILS OF CUTS, CONNECTIONS, HOLES, AND OTHER PERTINENT
DATA. INDICATE WELDS BY STANDARD AWS 2.1 SYMBOLS SHOWING SIZE, LENGTH AND
TYPE OF EACH WELD. SUBMITTED STRUCTURAL STEEL SHOP DRAWINGS TO THE
CONTRACTING OFFICER FOR APPROVAL.
K. WELD MISCELLANEOUS STEEL CONNECTIONS ALL AROUND WITH ONE-QUARTER-INCH
FILLET WELD UNLESS OTHERWISE NOTED, EXCEPT FOR SLOTTED CONNECTIONS.
L. THE CONTRACTOR SHALL NOT RELEASE BEAMS OR DIAGONAL BRACING FROM HOISTING
CABLES UNTIL ALL MEMBERS ARE SECURE WITH AT LEAST (2) BOLTS. ALL FIELD WELDED
CONNECTIONS SHALL BE COMPLETED BEFORE RELEASING CABLES.
V. POST- INSTALLED ANCHORS
A. EXCEPT WHERE INDICATED ON THE DRAWINGS, PROVIDE POST-INSTALLED ANCHORS
CONSISTING OF THE FOLLOWING ANCHOR TYPES:
1. MEDIUM DUTY MECHANICAL ANCHORS FOR CRACKED AND UNCRACKED CONCRETE USE:
(1) EXPANSION ANCHOR WITH NON-HOLE CLEANING INSTALLATION OPTION OR HOLLOW
DRILL BIT AND SELF-CLEANING VACUUM SYSTEM AND ADAPTIVE TORQUE TOOL FOR
APPLICABLE SIZES WITH ICC ESR APPROVALS. WHERE ANCHORS ARE PERMITTED TO
BE INSTALLED IN CORED HOLES, USE CORE BITS WITH MATCHED TOLERANCES AS
SPECIFIED BY THE MANUFACTURER. PROPERLY CLEAN CORED HOLE PER
MANUFACTURER’S INSTRUCTIONS.
B. SUBSTITUTION REQUESTS FOR ALTERNATE POST INSTALLED ANCHOR PRODUCTS MUST BE
APPROVED IN WRITING BY THE CONTRACTING OFFICER PRIOR TO USE AND PROVIDE
CALCULATIONS DEMONSTRATING THAT THE SUBSTITUTED PRODUCT IS CAPABLE OF
ACHIEVING THE PERFORMANCE VALUES OF THE SPECIFIED PRODUCT. SUBSTITUTIONS
WILL BE EVALUATED BY THEIR HAVING AN ICC ESR SHOWING COMPLIANCE WITH THE
RELEVANT BUILDING CODE FOR SEISMIC USES, LOAD RESISTANCE, INSTALLATION
CATEGORY, AND AVAILABILITY OF COMPREHENSIVE INSTALLATION INSTRUCTIONS.
C. INSTALL ANCHORS PER THE MANUFACTURER INSTRUCTIONS, AS INCLUDED IN THE ANCHOR
PACKAGING.
D. ARRANGE AN ANCHOR MANUFACTURER’S REPRESENTATIVE TO PROVIDE ONSITE
INSTALLATION TRAINING FOR ALL OF THEIR ANCHORING PRODUCTS SPECIFIED. SUBMIT
WRITTEN CONFIRMATION THAT ALL OF THE CONTRACTOR’S PERSONNEL WHO INSTALL
ANCHORS ARE TRAINED PRIOR TO THE COMMENCEMENT OF INSTALLING ANCHORS.
E. ANCHOR CAPACITY IS DEPENDENT UPON SPACING BETWEEN ADJACENT ANCHORS AND
PROXIMITY OF ANCHORS TO EDGE OF CONCRETE. INSTALL ANCHORS IN ACCORDANCE
WITH SPACING AND EDGE CLEARANCES INDICATED ON THE DRAWINGS
F. INSTALL ANCHORS IN CONCRETE IN INDOOR ANCHOR APPLICATIONS THAT IS DRY.
G. PROVIDE MECHANICAL ANCHORS THAT HAVE BEEN TESTED AND QUALIFIED FOR USE IN
ACCORDANCE WITH ACI 355.2 AND ICC-ES AC 193 FOR CRACKED, UNCRACKED AND SEISMIC
CONCRETE RECOGNITION
VI. GENERAL
A. INFORMATION SHOWN REGARDING EXISTING CONDITIONS HAS BEEN OBTAINED BY LIMITED
VISUAL OBSERVATIONS AND/OR FROM EXISTING DRAWINGS BY EWING COLE DATED
AUGUST 17, 2005, PROVIDED BY THE OWNER. AREAS NOT VISIBLE HAVE BEEN ASSUMED
TYPICAL WITH OBSERVED EXISTING CONDITIONS.
B. MEASURE AND PROVIDE ALL DIMENSIONS, ELEVATIONS AND CONDITIONS AT THE JOB SITE
PRIOR TO CONSTRUCTION AND THE SUBMISSION OF SHOP DRAWINGS, AND NOTIFY THE
CONTRACTING OFFICER IMMEDIATELY OF ANY DISCREPANCIES. PROVIDE VERIFICATION
AND NOTIFICATION AT LEAST TWO WEEKS PRIOR TO THE START OF WORK SO THAT ANY
NECESSARY CHANGES CAN BE MADE WITHOUT DELAYING THE PROJECT SCHEDULE.
C. DETAILS, SECTIONS, AND NOTES SHOWN ON THESE DRAWINGS ARE INTENDED TO BE
TYPICAL AND APPLY TO SIMILAR CONDITIONS ELSEWHERE UNLESS OTHERWISE SHOWN OR
NOTED.
D. PROVIDE SHOP DRAWINGS SUBMITTED TO THE CONTRACTING OFFICER BEARING THE
CONTRACTOR'S STAMP, DATE AND SIGNATURE THAT VERIFIES THAT THE DOCUMENTS HAVE
BEEN REVIEWED AND CORRECTED FOR CONFORMANCE TO AND COORDINATION WITH
CONTRACT DOCUMENTS.
E. PROCEED WITH FABRICATION ONLY AFTER SHOP DRAWING APPROVAL BY THE ENGINEER.
F. DO NOT REPRODUCE ANY PORTION OF CONTRACT DOCUMENTS IN THE SHOP DRAWINGS.
G. SUBMIT INSPECTION REPORTS AND MATERIALS TESTING REPORTS TO THE CONTRACTING
OFFICER IN A TIMELY MANNER SUCH THAT CONSTRUCTION DELAY WILL BE AVOIDED.
H. MEANS AND METHODS OF CONSTRUCTION ARE THE SOLE RESPONSIBILITY OF THE
CONTRACTOR.
I. WHERE THE CONTRACTOR IS REQUIRED TO ENGAGE A PROFESSIONAL ENGINEER TO
DESIGN AND SUBMIT CALCULATIONS, AND WHERE THE PROFESSIONAL ENGINEER
PREPARES THE CALCULATIONS USING A COMPUTER SOFTWARE SYSTEM, USE SOFTWARE
THAT IS READILY AVAILABLE, INDUSTRY STANDARD FOR STRUCTURAL ENGINEERING IN
COMMON USE.
VII. GREEN ROOF ASSEMBLIES
A. LANDSCAPED AND HARDSCAPED AREAS SHALL ONLY BE INSTALLED IN AREAS APPROVED
BY THE CONTRACTING OFFICER.
B. MAINTENANCE OF THE GREEN ROOF COMPONENTS AND PLANT GROWTH CONTROL TO
PREVENT STRUCTURAL OVERLOAD AND SERVICEABILITY ISSUES IS THE RESPONSIBILITY OF
THE OWNER.
C. SEE STRUCTURAL LOADING MAPS FOR LOCATION AND LIMITS OF SUPERIMPOSED DEAD AND
LIVE LOADS. SECTIONS INDICATED ON LOAD MAPS SHOW INTENT OF DESIGN. COORDINATE
WITH LANDSCAPE ARCHITECT AND GREEN ROOF ASSEMBLY MANUFACTURER/SUPPLIER TO
VERIFY THAT LANDSCAPED AND HARDSCAPED DESIGNS ARE WITHIN THE STRUCTURAL
LOAD LIMITS PROVIDED.
D. PROVIDE SUBMITTAL FOR:
1. WEIGHTS AND THICKNESS OF ALL COMPONENTS AND LAYERS. SELECTED ENGINEERED
FILL SHALL INCLUDE SATURATED AND UNSATURATED DENSITY AS WELL AS
PERMEABILITY DATA.
2. DETAIL SECTIONS OF SELECTED GREEN ROOF ASSEMBLIES.
E. FABRICATE AND TEST A MOCKUP OF THE FINAL GREEN ROOF ASSEMBLY FOR REVIEW AND
APPROVAL MOCKUP AND MATERIALS SHALL BE TESTED IN ACCORDANCE WITH ASTM E2397
AND ASTM E2399. LOAD AND VOLUME FLOW DATA SHALL BE PROVIDED FOR REVIEW.
VIII. TESTING AND INSPECTION
THE CONTRACTOR WILL RETAIN THE SERVICES TESTING AND INSPECTION AGENCY TO
PERFORM THE SERVICES SPECIFIED.
A. PROVIDE SERVICES ACCORDANCE WITH REQUIREMENTS OF THE LOCAL JURISDICTION AT A
MINIMUM.
B. FAILURE TO RETAIN A TESTING AGENCY TO PROVIDE REQUIRED SERVICES OR A FAILURE TO
SUBMIT SIGNED AND SEALED REPORTS IS A NON-COMPLIANCE WITH CONTRACT
DOCUMENTS.
C. REMOVE AND REPLACE CONSTRUCTION CONSIDERED NON-COMPLIANT.
D. ALL TESTING AND INSPECTION SHALL BE UNDER THE DIRECTION OF A PROFESSIONAL
ENGINEER LICENSED TO PRACTICE IN THE LOCAL JURISDICTION.
E. PROVIDE PRELIMINARY HANDWRITTEN SITE VISIT REPORTS CONFIRMING VERBAL
DISCUSSIONS TO THE CONTRACTOR REGARDING THE RESULTS OF INSPECTIONS PRIOR TO
LEAVING JOB SITE.
F. SUBMIT FINAL REPORTS TO THE CONTRACTING OFFICER IN A TIMELY MANNER, BUT NO
LATER THAN TEN (10) DAYS FOLLOWING INSPECTION OR TESTING UNDER THE NAME AND
SIGNATURE OF THE INSPECTOR AND LICENSURE SEAL AND SIGNATURE OF THE
PROFESSIONAL ENGINEER RESPONSIBLE FOR TESTING AND INSPECTION.
G. PROVIDE INSPECTION FOR THE FOLLOWING AT A MINIMUM:
1. STRUCTURAL STEEL: LOCATION, ASTM DESIGNATION, MEMBER SIZES, TYPE (PAINTED,
GALVANIZED), PLACEMENT AND CONNECTIONS INCLUDING WELDS, BOLTS, AND POST
INSTALLED ANCHORS.
2. WOOD: LUMBER, FOR IMPERFECTIONS THAT ARE CAUSE FOR REJECTION, NAILING,
BOLTED PLATES, AND OTHER CONNECTIONS.
H. PROVIDE MATERIAL TESTING THE FOLLOWING:
1. STRUCTURAL STEEL: YIELD AND ULTIMATE STRENGTHS. (MILL REPORTS ARE
ACCEPTABLE.)
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S
TE
M S
C O
M M
A N
D
W A
S H
IN
G
TO
N
N A
V A
L S
U P
P O
R T
A C
T
IV
IT
Y
B E
T H
E S
D A
M
A R
Y L
A N
D
AS NOTED
P U
B L
IC
W
O R
K S
D E
P A
R T
M E
N T
B
E T
H E
S D
A
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 32719,
EXPIRATION DATE 02/09/24.
AS DBSO
1698751
FINAL DESIGN SUBMISSION
F
IN
A L
D E
S
IG
N S
U B
M
IS
S
IO
N
/2 8/
/1
/2
:5
:0
P
M
S-001
U S
U -7
R o o f G a rd e n
D e s ig n
D E
S
IG
N N
O
TE
S
E nt er a dd re ss h er e
O w ne r
S -0
P ro je c t S ta tu s I s s u e D a te
Is su e D at e
P ro je ct
S ta tu s
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
13148364
E
E
F
F
EX. W14X90 COL.
EX. W14X90 COL., SEE NOTE 3
EX. W14X90 COL.
EX. W14X74 COL.
EX. W14X74 COL.,
SEE NOTE 3
EX. W14X90 COL.
EX. W14X90 COL.,
SEE NOTE 3
EX. #3x13'-0" BOT IN EACH
DECK FLUTE
EX. BOTTOM
FLANGE BRACING,
SEE 2/S501
NOTE 2
E X
. W
X
[8
E X
. W
X
[8
E X
. W
X
[1
7]
EX. W24X76 [15]
E X
. W
X
[1
5]
EX. W24X55 [15]
E X
. W
X
[1
5]
EX. W24X117 [15]
E X
. W
X
[1
7]
EX. W12X14 [6]
EX. W12X14 [6]
EX. W12X14 [6]
EX. W12X14 [6]
E X
. W
X
[1 7]
E X
. W
X
[2 0]
E X
. W
X
[2 0]
E X
. W
X
[2 0]
EX. W8X18EX. W8X18EX. W8X18EX. W24X76 [15]
EX. W24X55 [15]
EX. W24X117 [15]
S-501S-101
(6) HSS 6x6x3/8
TRELLIS POSTS
SPACED EQUALLY,
SEE NOTE 7. SEE
ARCH FOR
LOCATIONS
S-502S-101
EXTERIOR FACE OF EX. BRICK WALL
S-501S-101
S-501S-101
SEE NOTE 6
HSS 3.5x3.5x5/16 GUARDRAIL POST @ 6'-0"
O.C. MAX, TYP. SEE NOTE 8. PROVIDE 5/16"
3"x3" BENT PLATES BETWEEN TOP AND
BOTTOM RAILS FOR ATTACHMENT OF
SLATS.
SEE NOTE 6
0" 0"
0" 0"
SEE NOTE 6
EDGE OF EX. SLAB, SEE ARCH
W8x31
W8x31
W8x31
W8x31
W
T
.5 x
.5
W
T
.5 x
.5
S-502S-101
S-502S-101
W
T x
.5
W
T x
.5
S-502S-101 1
S-502S-101
W8x31
W8x31
W8x31
PROVIDE WELDED-BOLTED
AISC DOUBLE ANGLE
CONNECTION, TYPICAL
SEE NOTE 9.
SEE NOTE 9.
L3x3x5/16 KICKER AT
GUARDRAIL POST LOCATION,
TYPICAL.
S-501S-101
STEEL SUNDAIL
S-501S-101
30' - 0" ±
S-502S-101
N
E F
TRELLIS
SUNDIAL
LOADING DEAD LOAD(1) LIVE LOAD
6" OF SOIL 65 PSF 30 PSF (2)
6"-12" OF SOIL 65-117 PSF 30 PSF (2)
MAX 12" OF SOIL ON MAX. 15" OF 117 PSF 30 PSF (2)
TAPPERED INSULATION
WOOD PAVERS (3) 20 PSF 50 PSF
6" GRAVEL 85 PSF 30 PSF (2)
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH MANAGER
CHIEF ENG/ARCH
FIRE PROTECTION
N A
V A
L
FA
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S
TE
M S
C O
M M
A N
D
W A
S H
IN
G
TO
N
N A
V A
L S
U P
P O
R T
A C
T
IV
IT
Y
B E
T H
E S
D A
M
A R
Y L
A N
D
AS NOTED
P U
B L
IC
W
O R
K S
D E
P A
R T
M E
N T
B
E T
H E
S D
A
3200 LEE HIGHWAY, ARLINGTON, VA 22207
(703) 524 - 6616 www.mtfa.net
PROFESSIONAL CERTIFICATION. I
CERTIFY THAT THESE DOCUMENTS WERE
PREPARED OR APPROVED BY ME AND
THAT I AM A DULY LICENSED ENGINEER
UNDER THE LAWS OF THE STATE OF
MARYLAND, LICENSE NUMBER 32719,
EXPIRATION DATE 02/09/24.
AS DBSO
1698751
FINAL DESIGN SUBMISSION
F
IN
A L
D E
S
IG
N S
U B
M
IS
S
IO
N
/2 8/
/1
/2
:2
:2
P
M
S-101
U S
U -7
R o o f G a rd e n
D e s ig n
P A
R
TI
A L
LE
V
E L
(R
O O
F) F
R A
M
IN
G P
LA
N
E nt er a dd re ss h er e
O w ne r
S -1
P ro je c t S ta tu s I s s u e D a te
Is su e D at e
P ro je ct
S ta tu s
1/4" = 1'-0"S-101 S-101
1 PARTIAL LEVEL 2 (ROOF) FRAMING PLAN
NOTES:
1. INDICATES EX. MOMENT CONNECTIONS.
2. INDICATES EX. 3 1/4" L.W. CONC. OVER 3" 20 GA. GALV. COMPOSITE METAL DECK. REINFORCED WITH #3@12" CONT. EACH WAY (TOP OUTER LAYER EAST-WEST).
3. EX. 3/8" COLUMN WEB DOUBLER PL AT MOMENT CONNECTION.
4. [#] INDICATES THE NUMBER OF EX. 3/4" Ø x 5" LONG HEADED STUDS WELDED TO THE TOP FLANGE OF BEAMS.
5. REMOVE FIREPROOFING AT ALL EXIST. BEAM TO BEAM AND BEAM TO COLUMN CONNECTIONS ENCLOSED BY GRIDS E-F AND 1-2. SUBMIT REPORT WITH EX.
CONNECTION INFORMATION AS REQUESTED ON SHEET S-503 TO THE CONTRACTING OFFICER. [FOR BIDDING PURPOSES, ASSUME STRENGTHENING AT ALL EX.
CONNECTIONS, PER NOTES 4 AND 5 ON S-503.]
6. BRACE BOTTOM FLANGE OF EXISTING BEAM. SEE 5/S501.
7. DEMO EX. CONCRETE AND METAL DECK FOR INSTALLATION OF NEW TRELLIS POSTS. REPLACE CONC. AFTER POST INSTALLATION. PRIOR TO DEMO, GPR SCAN TO
LOCATE EX. REINFORCEMENT SO IT IS NOT CUT OR DAMAGED DURING DEMOLITION. SEE 6/S-501 FOR POST TO EX. BEAM CONN.
8. DEMO EX. CONCRETE AND METAL DECK FOR INSTALLATION OF NEW GUARDRAIL POSTS. PATCH REPAIR AFTER INSTALLATION. PRIOR TO DEMO, GPR SCAN TO LOCATE
EX. REINFORCMENT.
9. REMOVE EX. BRACING ONLY WHERE INDICATED FOR INSTALLATION OF NEW BEAM.
10. ALL NEW STEEL TO BE HOT-DIPPED GALVANIZED AND PAINTED. PROVIDE PREP AND TOUCH UP FOR FIELD WELDS.
1/8" = 1'-0"S-101 S-101
2 ROOF GARDEN UNIFORM LOAD DIAGRAM
(1) INCLUDES WEIGHT OF ROOFING AND GREEN ROOF/PAVER
ASSEMBLY. EXCLUDES EXISTING MEP AND CEILING.
(2) LIVE LOAD REDUCTION PERMITTED
(3) PAVER MANUFACTURER'S PROFESSIONAL ENGINEER TO PROVIDE
ATTACHMENT FOR PAVERS TO RESIST WIND UPLIFT. REFER TO S001. OTHER
DESIGN PRESSURES MAYBE USED IF SIGNED & SEALED CALCULATIONS ARE
SUBMITTED FOR REVIEW
S Y
M D
E S
C R
IP
T
IO
N
D A
T E
A P
P
13148365
EX. PL 1/4x3x0'-3", TYP.
EX. 7/8" DIA. ROD
EX. PL 1/4x4x0'-4", TYP.
EX. FLOOR BEAM OR GIRDER, SEE PLAN
EX. L2x2x3/16
INDIC ATED ON PLAN
EX. BOT FLG BRACING
INDICATED ON PLAN
EX. BOT FLG BRACING
EX. COMPOSITE
CONCRETE METAL
DECK, SEE PLAN
TEMP. REMOVE/RELOCATE EX. MEP
CONFLICTS FOR INSTALLATION OF NEW
BEAMS AND STRENGTHENING.
REINSTALL/RELOCATE AFTER
COMPLETITION OF WORK. REFER TO MEP
DRAWINGS FOR LOCATION OF EXISTING
CONFLICTS.
NEW STRENGTHENING, SEE PLAN
NEW STRENGTHENING,
SEE PLAN
EX. CONT. 4x4x5/16
T/ SLAB
SEE ARCH
EX. CONT. #4 REBAR
TO REMAIN, DO NOT
DAMAGE
GREEN ROOF, SEE
LANDSCAPE DRAWINGSEX. 4" BRICK
EX. 6" LT. GA STUDS
EX. BEAM, SEE PLAN
DO NOT DAMAGE EX.
REINFORCEMENT, SEE PLAN. GPR
SCAN TO LOCATE EX.
REINFORCEMENT PRIOR TO
REMOVING EX. SLAB FOR POST
INSTALLATION.
RIGID INSULATION AND
ROOFING, SEE ARCH
EX. LT. GA.
CONNECTION,
SEE NOTE 1
EX. COMPOSITE CONCRETE
METAL DECK, SEE PLAN
EX. SHEET METAL
CLOSURE AT EDGE
OF SLAB
3/8" FULL HEIGHT
STIFFENER AT GUARDRAIL
POST LOCATIONS.
5 3/8" ±
GUARDRAIL ASSEMBLY, SEE ARCH.
HSS2x2 BOTTOM RAIL, SEE
DETAIL 4/S502 FOR CONNECTION
SEE NOTE 2
HSS3 1/2x3 1/2 GUARDRAIL POST
WELD TO TOP OF EX. BEAM WITH
1/4" FILLET WELD ALL AROUND
L3x3x5/16 KICKER AT GUARDRAIL
POSTS, SEE PLAN. ATTACH TO DECK
WITH L6X4X3/8 W/ (3) 3/8Ø EXPANSION
ANCHOR AT DECK FLUTES.
1/4
1/4
F
EX. CONT. L5x4x5/16, LLV
T/ SLAB
SEE ARCH
EX. SHEET MTL
CLOSURE
EX. (1) #4 CONT TO
REMAIN, DO NOT DAMAGE
EX. 4" BRICK
EX. 6" LT. GA STUDS
EX. LT. GA. CONNECTION,
SEE NOTE 1 EX. COMPOSITE CONCRETE
ON METAL DECK, SEE PLAN
RIGID INSULATION AND
ROOFING, SEE ARCH
DO NOT DAMAGE EX.
REINFORCEMENT, SEE PLAN.
GPR SCAN TO LOCATE EX.
REINFORCEMENT PRIOR TO
REMOVING EX. SLAB FOR
POST INSTALLATION.
EX. WF BEAM, SEE PLAN
5 3/8" ±
SEE NOTE 2.
SEE 3/S-501 FOR
GUARDRAIL INFORMATION
GREEN ROOF, SEE
LANDSCAPE DRAWINGS
EX. CONT. 4x4x5/16
T/ SLAB
SEE ARCH
GREEN ROOF, SEE
LANDSCAPE DRAWINGSEX. 4" BRICK
EX. 6" LT. GA STUDS
EX. BEAM, SEE PLAN
RIGID INSULATION AND
ROOFING, SEE ARCH
EX. COMPOSITE CONCRETE
ON METAL DECK, SEE PLAN
EX. SHEET METAL
CLOSURE AT EDGE
OF SLAB
NEW 3/8" PLATE
5 3/8" ±
EX. WF BEAM, SEE PLAN
EX. DOUBLE ANGLE
CONNECTION, VIF.
NEW FULL LENGTH
STRENGTHENING, SEE PLAN
SEE 3/S-501 FOR
GUARDRAIL INFORMATION
6"
0' - 6"
EX. 2 COURSES OF 6" CMU, WITH
GROUTED TOP COURSE &
GROUTED CELLS @ EX. DOWELS
EX. #4 DOWELS @ 32" OC
INTO CONC.
EX. BRICK
EX. #3@12" O.C. EW.
EX. #3 x 13'-0" BOTTOM REBAR @
EA. DECK FLUTE
EX. 6" LT. GA. STUDS
@16" O.C.
E
EX. WF BEAM,
SEE PLAN
EX. HEADED STUD
GREEN ROOF, SEE
LANDSCAPE DRAWINGS
HSS6x6x3/8
TRELLIS POST
1/4
8"W8 SUPPORT
BEAM, SEE
PLAN
3/8" STIFF PL.
ON EA SIDE
OF BM. WEB
SEE NOTE 1
EX. COMPOSITE
CONC. ON METAL
DECK, SEE PLAN
1/4
SEE NOTE 1
SATISFACTORY TO DATE
APPROVED
ACTIVITY
FOR COMMANDER NAVFAC
SEAL
A/E INFO
A
B
C
D
1 2 3 4 5
1 2 3 4 5
A
B
C
D
SCALE:
CONSTR. CONTR. NO.
SHEET
NAVFAC DRAWING NO.
DES DRW CHK
OF
EPROJECT NO.:
D E
P A
R T
M E
N T
O F
T H
E N
A V
Y N
A V
A L
F A
C
IL
IT
IE
S E
N G
IN
E
E R
IN
G
S Y
S T
E M
S C
O M
M A
N D
DRAWFORM REVISION: 25 AUGUST 2020
PM/DM
BRANCH…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .