This document contains information related to a state and local contract opportunity for the Clackamas County Fairgrounds Multiuse Building Project. The County is accepting sealed bids until July 13, 2023 at 2:00 PM Pacific Time for this project. The project involves the construction of a multi-purpose building at the Clackamas County Fairgrounds located in Canby, Oregon. The bid documents include detailed plans and specifications for the plumbing work, including site plans, floor plans, riser diagrams, schedules, and details.

The bid documents provide extensive technical information about the plumbing systems and requirements, including details on pipe routing, fixture types and connections, water and gas piping, drainage and venting systems, and related equipment such as water heaters and pumps. The documents include detailed plumbing fixture and equipment schedules specifying manufacturer, model numbers, and connection sizes. Additionally, the documents contain gas piping sizing calculations and details for gas regulator vents.

View the file

Other files

Show all 22

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

A CONDITIONS SHOW ON THE PLANS RELATIVE TO THE WORK TO BE

PERFORMED ARE BASED ON THE BEST INFORMATION AVAILABLE BUT ARE

SUBJECT TO VERIFICATION. VERIFY LOCATIONS AND ELEVATIONS OF

UTILITIES TO BE CROSSED OR CONNECTED. CORRECT DEFICIENCIES

CAUSED BY FAILURE TO PERFORM SUCH VERIFICATIONS AT NO EXPENSE TO

OWNER. IMMEDIATELY NOTIFY ARCHITECT AND ENGINEER OF CONDITION IN

CONFLICT WITH THE DETAILS/PLANS.

B PROVIDE GAS SHUTOFF VALVES, PRESSURE REGULATORS AND UNION

AT CONNECTIONS TO GAS-FIRED EQUIPMENT. PROVIDE REGULATOR RELIEF

VENT PIPING TO ATMOSPHERE WHERE REQUIRED BY CODE.

C COORDINATE INSTALLATION OF PIPING BELOW AND ABOVE GRADE WITH

STRUCTURAL COMPONENTS AND OTHER SYSTEMS INSTALLATION.

D COORDINATE FIXTURES, EQUIPMENT, PIPE ROUGH-IN/CONNECTION

LOCATIONS AND DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS.

E ALL PIPING SYSTEMS CROSSING SEISMIC SEPARATIONS SHALL UTILIZE PRE-

MANUFACTURED EXPANSION JOINT SYSTEM, SIZED FOR 4 INCH X, Y AND Z

MOVEMENT. UNISOURCE 'V' TYPE, HYSPAN OR APPROVED.

F PIPING ROUTED THROUGH ROOF TO BE INSTALLED PER ARCHITECTURAL

REQUIREMENTS (SEE ARHICTECTURAL DETAILS).

G LOCATE ALL VTR A MINIMUM OF 10'-0" FROM OUTSIDE AIR OPENINGS OF

ROOFTOP HVAC EQUIPMENT.

H EXTERIOR HOSE BIBBS TO BE MOUNTED AT 24 INCHES ABOVE FINISH

GRADE (UNLESS SPECIFICALLY NOTED OTHERWISE).

I LOCATE VALVES FOR SERVICE ACCESSIBILITY. VALVES INSTALLED ABOVE

CEILING SHALL BE WITHIN 18" OF CEILING.

J INSTALL OVERHEAD PIPING AS CLOSE TO STRUCTURE AS POSSIBLE IN

AREAS WITH EXPOSED ROOF STRUCTURE.

K REFER TO SPECIFICATIONS FOR SEISMIC RESTRAINT REQUIREMENTS FOR

PIPING AND EQUIPMENT.

L DOWNSPOUT RISERS AND STORM DRAIN RISERS TO BE PROVIDED WITH

CLEANOUT AT BASE OF VERTICAL STACK. SIMILAR TO DETAILS

3/P902___

M PROVIDE CLEANOUTS FOR SANITARY WASTE AND STORM DRAINAGE SYSTEMS

WHERE SHOWN AND AS OTHERWISE REQUIRED BY CODE.

N VERIFY LOCATIONS OF CONNECTIONS TO PIPING INSTALLED BY

SITE CONTRACTOR.

O PIPING INSTALLED IN EXTERIOR WALLS TO BE INSTALLED ON WARM

SIDE OF INSULATION.

P FURNISH AND INSTALL VALVES, TRAPS, STRAINERS, BACK FLOW PREVENTERS,

ETC. NOT FURNISHED BY EQUIPMENT SUPPLIER, BUT REQUIRED

FOR PROPER EQUIPMENT OPERATION.

Q SHUT-OFF VALVES TO BE INSTALLED IN ALL WATER AND GAS PIPING AT

LOCATIONS SHOWN. PROVIDE ACCESS PANELS IF CEILING

AND STRUCTURAL CONDITIONS DO NOT ALLOW NORMAL ACCESS.

COORDINATE EXACT TYPE AND LOCATION WITH OWNER AND GENERAL

CONTRACTOR PRIOR TO ROUGH-IN.

R CONTRACTOR TO PROVIDE LOCATE/SCOPING SERVICES FOR EXISTING

PIPING BELOW GRADE AND DOCUMENT/RECORD, COORDINATE WITH

NEW WORK PRIOR TO START OF CONSTRUCTION.

S ROOF PENETRATIONS TO BE MINIMUM 5'-0" CLEAR OF

TWO HOUR WALL SEPARATIONS.

T SEE PLUMBING FIXTURE SCHEDULE FOR PIPE CONNECTION SIZES.

U COORDINATE INSTALLATION OF DUCTWORK, PIPING, FIXTURES, EQUIPMENT, ETC.

WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND FIRE

PROTECTION SYSTEMS PRIOR TO INSTALLATION.

V REFER TO ARCHITECTURAL DRAWINGS FOR ADA ACCESSIBILITY REQUIREMENTS.

W PROVIDE CEILING ACCESS PANELS FOR VALVES LOCATED ABOVE

INACCESSIBLE CEILING SYSTEMS. VALVES INSTALLED ABOVE CEILING SHALL BE

WITHIN 18" OF CEILING. MAINTAIN FIRE RATINGS WHERE REQUIRED.

X SEE ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATIONS.

Y REFER TO SPECIFICATIONS FOR SEISMIC RESTRAINT

REQUIREMENTS FOR PIPING/EQUIPMENT.

GENERAL NOTES

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

EXPIRES: 12/31/23

/1

/2

:1

:4

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

CG

P000

SYMBOL LIST

AND GENERAL

NOTES -

PLUMBING

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

P000 SYMBOL LIST AND GENERAL NOTES - PLUMBING

P201 OVERALL UNDERGROUND PLAN

P202 OVERALL PLUMBING FLOOR PLAN

P203 ENLARGED PLAN AND RISER - NORTHEASTERN PLUMBING

UNDERGROUND

P204 ENLARGED PLAN AND RISER - NORTHEASTERN PLUMBING

P205 ENLARGED PLAN AND RISER - SOUTHEASTERN PLUMBING

UNDERGROUND

P206 ENLARGED PLAN AND RISER - SOUTHESTERN PLUMBING

P701 SCHEDULES - PLUMBING

P902 DETAILS - PLUMBING

SHEET INDEX

PLUMBING SYMBOL LIST

NOTE: This is a standard symbol list and not all items listed may be used.

General

CONTINUATION

EQUIPMENT IDENTIFICATION

EXTENT OF DEMOLITION

FIXTURE TAG (LEVEL BELOW FIXTURE)

KEYED NOTE

POINT OF CONNECTION

DEMOLISH

EXISTING WORK

NEW WORK

PIPE OR CONDUIT BELOW GRADE

Piping Fittings

ACCESS PANEL

AQUASTAT

BLIND FLANGE

CAP

CLEANOUT TO GRADE

CONCENTRIC REDUCER

DOWNSPOUT NOZZLE

ECCENTRIC REDUCER

FLOOR CLEANOUT

FLOOR DRAIN

FLOOR SINK

FLOW DIRECTION

HOSE BIBB / WALL HYDRANT

OVERFLOW ROOF DRAIN

PIPE DROP

PIPE RISE

PUMP

ROOF DRAIN

SHOCK ABSORBER / WATER HAMMER ARRESTOR

STRAINER

T&P RELIEF VALVE WITH PIPE TO DRAIN

TEE DOWN ON PIPE

TEE UP ON PIPE

VENT THROUGH ROOF

WALL CLEANOUT

Piping Systems

COLD WATER PIPING

CONDENSATE / INDIRECT DRAIN PIPING

HOT WATER PIPING

HOT WATER RETURN PIPING

NATURAL GAS PIPING, 2 LB

NATURAL GAS PIPING, 7" WC PRESSURE

OVERFLOW DRAIN PIPING ABOVE GRADE OR FINISHED FLOOR

SANITARY VENT PIPING

Abbreviations

(A) ABANDON IN PLACE

AFF ABOVE FINISHED FLOOR

AP ACCESS PANEL

& AND

A AQUASTAT, ARCHITECT, ANCHOR, AMPHERE

@ AT

BFP BACKFLOW PREVENTER

BFF BELOW FINISHED FLOOR

BTUH BRITISH THERMAL UNITS PER HOUR

BLDG BUILDING

CV CHECK VALVE

CO CLEANOUT

CW COLD WATER

CD CONDENSATE DRAIN

CONT. CONTINUATION

CFH CUBIC FEET PER HOUR

CFS CUBIC FEET PER SECOND

(X) DEMOLISH

DW DISHWASHER, DOMESTIC WATER

DET DOMESTIC EXPANSION TANK

DCVA DOUBLE CHECK VALVE ASSEMBLY

DN DOWN

DS DOWNSPOUT

DSN DOWNSPOUT NOZZLE

D DRAIN

DFU DRAINAGE FIXTURE UNIT

DWV DRAINAGE, WASTE AND VENT

DF DRINKING FOUNTAIN

EWC ELECTRIC WATER COOLER

EWH ELECTRIC WATER HEATER

(E) EXISTING

FT FEET

FFE FINISHED FLOOR ELEVATION

F FIRE, FAHRENHEIT

FL FLOOR

FCO FLOOR CLEANOUT

FD FLOOR DRAIN

FV FLUSH VALVE

' FOOT, FEET

(F) FUTURE

GPM GALLONS PER MINUTE

GWH GAS WATER HEATER

HVAC HEATING, VENTILATING AND AIR CONDITIONING

HZ HERTZ

HB HOSE BIBB

HW HOT WATER

HWFU HOT WATER FIXTURE UNIT

HWR HOT WATER RETURN

IN, " INCHES

IW INDIRECT WASTE

INV INVERT ELEVATION

L LAVATORY

MIN MINIMUM

MX MIXING VALVE

MS MOP SINK

(N) NEW

N NORTH

NIC NOT IN CONTRACT

NTS NOT TO SCALE

# NUMBER

NO. NUMBER

OD OVERFLOW DRAIN, OUTSIDE DIAMETER

OFCI OWNER FURNISHED, CONTRACTOR INSTALLED

OFOI OWNER FURNISHED, OWNER INSTALLED

PLBG PLUMBING

P PLUMBING, PUMP

POC POINT OF CONNECTION

PSI POUNDS PER SQUARE INCH

PD PRESSURE DROP, PLUMBING DEMOLITION, PUMPED DISCHARGE

PRV PRESSURE REDUCING VALVE

QTY QUANTITY

RWL RAINWATER LEADER

RPBP REDUCED PRESSURE BACKFLOW PREVENTER

(R) RELOCATE / RELOCATED LOCATION

RD ROOF DRAIN

SAN SANITARY

SB SERVICE BOX

SHT SHEET

SA SHOCK ARRESTOR

SOV SHUT OFF VALVE

S, SK SINK

SF SQUARE FEET

SD STORM DRAIN

SP SUMP PUMP, STATIC PRESSURE

TEMP TEMPERATURE

TP TRAP PRIMER, TOTAL PRESSURE

TYP TYPICAL

U, UR URINAL

V VACUUM, VENT, VOLT

VTR VENT THRU ROOF

WCO WALL CLEANOUT

W WASTE

WC WATER COLUMN, WATER CLOSET

WHA WATER HAMMER ARRESTOR

WH WATER HEATER, WALL HYDRANT

WSFU WATER SUPPLY FIXTURE UNIT

W/ WITH

SANITARY WASTE OR SOIL PIPING ABOVE GRADE OR FINISHED

FLOOR

SANITARY WASTE OR SOIL PIPING BELOW GRADE OR FINISHED

FLOOR

STORM DRAIN PIPING ABOVE GRADE OR FINISHED FLOOR

STORM DRAIN PIPING BELOW GRADE OR FINISHED FLOOR

TRAP PRIMER PIPING

Valves

BACKFLOW PREVENTER

CHECK VALVE

SHUTOFF VALVE, GENERAL

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

P203

P205

1 2 3 4 5 6 7 8 9 10 11 12

B

A

C

4" DS-1

(7,400 SQFT)

1 4" DS-1

(7,400 SQFT)

4" DS-1

(7,400 SQFT)

3" DS-1

(4,200 SQFT)

3" DS-1

(4,200 SQFT)11

3" DS-1

(4,200 SQFT)11

3" DS-1

(4,200 SQFT)

3" DS-1

(4,200 SQFT)

3" DS-1

(4,200 SQFT)

2" DS-1

(300 SQFT)

2" DS-1

(300 SQFT)

FD-1 FD-1 FD-1 FD-1 FD-1 FD-1 FD-1 FD-1

FCO

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

EXPIRES: 12/31/23

/1

/2

:1

:4

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

CG

P201

OVERALL

UNDERGROUND

PLAN

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

0' 8' 16' 32'

1/16" = 1'-0"

1 UNDERGROUND PLAN - PLUMBING N

O R T H

SHEET KEYNOTES

1. SEE CIVIL FOR CONTINUATION AND SEE DETAIL 3/P902 FOR DETAIL.

P204

P206

1 1/4" G 1" G

1 1/2" G

1 1/4" G

1 1/4" G

1 1/2" G

1 2 3 4 5 6 7 8 9 10 11 12

B

A

C

AHU-03

AHU-04

AHU-02

AHU-01

1 1/2" G

3 2

1" CW

1" CW

1" CW1" CW

3/4" CW

HB-1

HB-1

HB-1 HB-1 HB-1

HB-1

1 1 1

HB-11 HB-113/4" CW 1" CW 1" CW

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

EXPIRES: 12/31/23

/1

/2

:1

:5

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

CG

P202

OVERALL

PLUMBING

FLOOR PLAN

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

0' 8' 16' 32'

1/16" = 1'-0"

1 FIRST FLOOR PLAN - PLUMBING N

O R T H

SHEET KEYNOTES

1. ROUTE 3/4" PIIPNG DOWN TO HOSE BIBBS AND MOUNT HOSE BIBBS AT 24" AFF.

2. ROUTE PIPING IN MEZZANINE AGAINST AND ENSURE IT IS WITHIN SAFE CLEARANCE TO ANY OTHER

EQUIPMENT. ROUTE PIPING AROUND ANY STRUCTURAL ELEMENTS.

3. ROUTE PIPING DOWN TO 24" AFF AND OUT TO EQUIPMENT. SEE DETAIL 1/P902 FOR GAS CONNECTION DETAIL.

FCO

WC

WC

WC

WC

L

WC

L

WC

L

FCO

FCO

S

S

S

S

SH SH

CO

C W

L

10 11 12

A

WC

WC

S A

N

2" SAN

S A

N

SH

2" V

FD

2%

2%

4" SAN

4" SAN

S A

N

S A

N

S A

N

S A

N

4" SAN

4" SAN

4" SAN

4" SAN

4" SAN

4" SAN

FCO

2" SAN

S-1

S-1

S-1

S-1

WC-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

WCO

FCO

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1 WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

4" S

AN

4" S

AN

FD-1

WC-2

L-1

WC-2

WC-2

SH-1

SH-1

SH-1

FCO

2" V

1 1/2" V

2" V

2" V

V

V

2" V

S A

N

6" S

AN

4" SAN

2" SAN

4" S

AN

4" S

AN

4" S

AN

3" V

2" V

V

V

V 3

V

V

FCO

FCO

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

EXPIRES: 12/31/23

/1

/2

:1

:5

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

RM

P203

ENLARGED PLAN

AND RISER -

NORTHEASTERN

PLUMBING

UNDERGROUND

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

0' 4' 8' 16'

1/4" = 1'-0"

1 ENLARGED NORTHEASTERN UNDERGROUND PLAN - PLUMBING 2 NORTHEAST SANITARY RISER DIAGRAM

SHEET KEYNOTES

1. SEE CIVIL FOR CONTINUATION.

2. ROUTE VENT THRU ROOF LINES SEPARATELY TO ROOF AND AROUND SOLAR PANELS.

N O R T H

2 2 2 2

L-2

S-1

FIRE RISER

STORAGE

ELEC.

W SHOWERS

MECH.

10 11 12

A

WCO

S-1

S-1

S-1

SH-1

SH-1

L-1

L-1

L-1

L-1L-1

L-1

L-1

L-1

FCO

L-1

3/4" HW

3/4" HW

3/4" HWR

3/4" HWR

/4

H

W R

1" HW

1" CW 2" CW 2" CW

2" CW

/4

H

W

/4

H

W

H W

H W

R

C W

H W

/4

H

W R

/4

H

W R

3/4" HW

3/4" CW

3/4" HWR

C W

2 1/2" CW

2" CW

2 1/2" CW

2" CW

C W

C W

2" V

2" V

2" V

2" V

3" V

2" V

2" V

2" V

2" V

W SHOWERS

WELLNESS

WOMENS RR

RR

LOBBY

4" CW

FD-1

FCU-01

FCU-02

3/4" CW 3/4" HW

WC-2

1 1/2" V 2" V

FCO

FCO

FCO

3/4" D

3/4" D

1 1/2" G

/2

G

1 1/2" G

SH-1

WC-2

WC-2

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1 WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-2

C W

2 1/2" CW

1" CW

1" CW

HB-1

S-1 S-1

S-1

S-1

SH-1

SH-1

WC-1

L-1

L-1

L-1

L-1

L-1 L-1

WC-2

L-1

L-1

L-1

L-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-2

WC-2

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-1

1" HW

1" HWR

3" C W

2 1/2" CW

2 1/2" CW

2" C W

2" C W

4" C W

4" CW

C W

4" C W

3/4" H W

R

2" C W

1/2" H W

1/2" H W

R

3/4" H W

3/4" H W

2" CW

3/4" HW

1" CW

3/4" HWR

3/4" HW

1" HW

1" H W3/4" H W

R

3" C W

3" CW

1" HW

R1" HW

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

EXPIRES: 12/31/23

/1

/2

:1

:5

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

RM

P204

ENLARGED PLAN

AND RISER -

NORTHEASTERN

PLUMBING

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

0' 4' 8' 16'

1/4" = 1'-0"

1 ENLARGED NORTHEASTERN PLAN - PLUMBING 2 NORTHEASTERN DOMESTIC WATER RISER DIAGRAM

SHEET KEYNOTES

1. BALANCING VALVE, SET TO 0.5GPM.

2. 3" VTR TRHOUGH ROOF. VERIFY LOCATION OF FUTURE SOLAR PANELS BEFORE INSTALLING.

N O R T H

L

L

U

U

WC

FCO

FCO

FCO

CO

DF

FCO

FS

2" G UP TO METER

S A

N

4" SAN

S A

N

S A

N

IE: 62" BFF

10 11 12

C

SH

SH

SH

CO

MS

S A

N

CO

S A

N

6" SAN

S A

N

S A

N

S A

N

FS-1

FCO

FCO

6" S

AN

4" SAN

4" S

AN

DF-1

DF-1

DF-1

SH-2

SH-2

SH-1

WC-1

WC-1

WC-1

WC-1

WC-1

WC-2

L-1

L-1 L-1

L-1

L-1

L-1

L-1

L-1

WCO

MS-1

6" S

AN

6" SAN

4" S

AN

4" SAN

6" S

AN

4" SAN

4" S

AN

3" V

V

3" V

1 1/2" V

2" V

3" V

2" V

WCO

U-1

U-1

U-1

FCO

FCO

FS-1

U-1

U-1

U-1

U-1

U-1

FCO

FCO

WCO

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

EXPIRES: 12/31/23

/1

/2

:1

:5

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

RM

P205

ENLARGED PLAN

AND RISER -

SOUTHEASTERN

PLUMBING

UNDERGROUND

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

0' 4' 8' 16'

1/4" = 1'-0"

1 UNDERGROUND PLAN - PLUMBING 2 SOUTHEAST SANITARY RISER DIAGRAM

SHEET KEYNOTES

1. SEE CIVIL FOR CONTINUATION.

2. ROUTE VENT THRU ROOF LINES SEPARATELY TO ROOF AND AROUND SOLAR PANELS.

N O R T H

2 2

L-1

L-1

L-1

L-1

U-1

U-1

GWH-1

2 1/2" CW

DF-1

MENS RR

STORAGE

JANITOR

106A

OFFICE

L-1

L-1

L-1

L-1

U-1

U-1

U-1

U-1

U-1

U-1

WCO

FCO

FS-1

FCO

C W

NATURAL GAS METER,

2PSI

11 12

C

WCO

H W

R

H W

C W

H W

R

H W

CP-1

3/4" HW

3/4" CW

3/4" HWR

2" CW

2" CW

2 1/2" CW

1 1/4" CW

3/4" HW

3/4" HWR

1" HW

1" HWR

3" CW

C W

2" CW

V

1 1/2" CW

1 1/2" CW

2 1/2" CW

2" CW

DF-1

DF-1

SH-1

FCO

2" V

SH-2

SH-2

1 1/4" CW

1 1/2" G

3" V

WC-1

WC-1

WC-1

WC-1

WC-1

WC-2

MS-1

2" G

1" CW

/2

G

WCO

P902

1 1/2" G

HB-1

STORAGE

G

SH-1

SH-2

SH-2

U-1

U-1

U-1

U-1

U-1

U-1

U-1

U-1

1" C W

2" CW

2 1/2" CW

1 1/4" CW 3" C

W

1" HW

1" HWR

2" CW

2" CW

2" C W

2 1/2" CW

1" CW 3/4" HW

3/4" CW

3/4" CW

3/4" HW

3/4" HWR

3/4" HWR

3" CW

1" HW

1" HWR

DF-1

DF-1

DF-1

3/4" H W

R

GWH-1

CP-1

WC-2

WC-1 WC-1

WC-1

WC-1

WC-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

L-1

MS-1

3/4" HW

R3/4" HW

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

/1

/2

:1

:5

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

RM

P206

ENLARGED PLAN

AND RISER -

SOUTHESTERN

PLUMBING

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

0' 4' 8' 16'

1/4" = 1'-0"

1 ENLARGED SOUTHEASTERN PLAN - PLUMBING

0' 4' 8' 16'

2 SOUTHEAST DOMESTIC WATER RISER DIAGRAM

SHEET KEYNOTES

1. BALANCING VALVE, SET TO 0.5GPM.

2. 3" VTR TRHOUGH ROOF. SEE 2/P205 FOR ROUTING AROUND SOLAR PANELS.

N O R T H

EXPIRES: 12/31/23

SYMBOL FIXTURE TYPE DESCRIPTION MFR MODEL ACCESSORIES W V CW HW NOTES

LMV-1 LAVATORY MIXING

VALVE

THERMOSTATIC MIXING VALVE, ASSE

1070 COMPLIANT, INTEGRAL CHECK

VALVES, LEAD FREE, CHROME

SLOAN 3326009 --- --- 1/2" 1/2"

MMV-1 MASTER MIXING

VALVE

FULL PACKAGE SYSTEM WITH

HIGH/LOW FLOW MIXING VALVES,

GAUGES, PRV(S), VALVES, UNIONS

AND OTHER CONNECTIONS,

EXPOSED. 1 GPM TO 72 GPM AT 45

PSI MAX FALLOFF. SYSTEM PEAK =

39 GPM.

LEONARDTM-186-5015-PRV-RF-0 --- --- 3/4" 3/4"

NOTES:

PLUMBING DEVICES SCHEDULE

BASIS OF DESIGN CONNECTION

GAS DATA

GWH-1 WATER HEATER STORAGE 107 / DOMESTIC HOT

WATER

AO SMITH BTH-199 100 199 120 1 4 PROPANE-FIRED, BOILER, CONDENSING, DIRECT VENTING.

95% HIGH EFFICIENCY. [ASME] 5.6 GPM FLOW RATE AT 67F

TEMPERATURE RISE.

NOTES:

WATER HEATER SCHEDULE

SYMBOL EQUIPMENT TYPE LOCATION / SERVING

BASIS OF DESIGN TANK

CAPACITY

(GALLONS)

ELECTRICAL

COMMENTSMFR MODEL

INPUT

(MBH) VOLTS PH AMPS KW

FIXTURE QUANTITY FIXTURE QUANTITY TABLE 703.2 TABLE 703.2

PRIVATE PUBLIC PRIVATE PUBLIC TOTAL

INDIVIDUAL INDIVIDUAL INDIVIDUAL FIXTURE

DWELLING DESCRIPTION DWELLING DWELLING UNITS

0 4 SINK 2.00 2.00 8.00

0 18 LAVATORY, SINGLE 1.00 1.00 18.00

0 6 SHOWER, STALL, 2" TRAP 2.00 2.00 12.00

0 28 WATER CLOSET, 1.28 GPF, FLUSHMETER VALVE 3.00 4.00 112.00

0 3 DRINKING FOUNTAIN 0.50 0.50 1.50

0 1 MOP SINK -- 3.00 3.00

0 9 FLOOR DRAIN -- 4.00 36.00

0 1 FLOOR SINK -- 4.00 4.00

194.50

MINIMUM PIPE SIZE 6.00

SANITARY DRAINAGE

CALCULATIONS

PRIVATE PUBLIC PRIVATE PUBLIC

INDIVIDUAL USE INDIVIDUAL USE COLD

DWELLING DESCRIPTION DWELLING WATER

APPENDIX A SIZING WATER SUPPLY SYSTEM

0 1 HOSE BIBB 2.50 2.50 2.50

0 9 HOSE BIBB, EACH ADDITIONAL 1.00 1.00 9.00

0 18 LAVATORY 1.00 1.00 18.00

0 4 SINKS 1.50 1.50 6.00

0 6 SHOWER, PER HEAD 2.00 2.00 12.00

0 28 WATER CLOSET, 1.28 GPF, FLUSH VALVE 5.00 5.00 140.00

0 1 MOP SINK 1.50 3.00 3.00

0 3 DRINKING FOUNTAIN 0.50 0.50 1.50

TOTAL: 190.50

FLOW (GPM): 89.00

a MINIMUM DAILY SERVICE PRESSURE 58 b WATER METER PRESSURE DROP 5 c BACKFLOW PREVENTER 7

d. STATIC HEAD LOSS 25 FT X .434 /FT 13.02

e. PRESSURE REQUIRED AT FIXTURE 30

PRESSURE AVAILABLE FOR

FRICTION LOSS, a - b - c - d - e 2.98

400 TOTAL EQUIVALENT PIPE LENGTH

LENGTH X 1.25 500

MAXIMUM FRICTION LOSS

PRESS. AVAIL. X 100'/EQUIV. LENGTH 0.60

SERVICE SIZE FROM METER TO BUILDINGS 4

WATER SERVICE CALCULATIONS

2021 OREGON PLUMBING SPECIALTY CODE

QTY TOTAL FIXTURE UNITS

DOMESTIC WATER

SYMBOL FIXTURE TYPE DESCRIPTION MFR MODEL ACCESSORIES W V CW HW NOTES

DF-1 DRINKING FOUNTAIN WALL MOUNTED, DOUBLE BOWL, 18

GAUGE STAINLESS STEEL, SATIN

FINISH, VANDAL RESISTANT BUBBLER,

FRONT PUSHBUTTON. PROVIDE WITH

WALL PLATE

SUNROC ADA8ACB-STN 1-1/2" 1-1/2" 1/2" --

DS-1 DOWNSPOUT BOOT CAST IRON BODY AND STRAP, 4-INCH

ROUND

JR SMITH 1787 4" -- -- --

FD-1 FLOOR DRAIN

(UNFINISHED FLOORS /

MECHANICAL ROOMS)

CAST IRON BODY, FLASHING COLLAR,

8-1/2-INCH ROUND ADJUSTABLE TOP,

BAR GRATE, SEDIMENT BUCKET, TRAP

PRIMER

JR SMITH 2350Y-

P050

3"* 1-1/2"*PRIMER CONN. --

FS-1 FLOOR SINK CAST IRON FLANGED RECEPTOR,

SEEPAGE HOLES, ACID RESISTANT

COATED INTERIOR, NICKEL BRONZE

RIM, 1/2-GRATE, ALUMINUM DOME

BOTTOM STRAINER, 6-INCH DEEP

JR SMITH 3140Y-12 3"* 1-1/2"*PRIMER CONN. --

HB-1 HOSE BIBB ENCASED, NON-FREEZE, ANTI-SIPHON,

AUTOMATIC DRAINING, CHROME

PLATED BOX/DOOR ASSEMBLY,

DOUBLE CHECK BACKFLOW

PREVENTER

WOODFORD B67-P -- -- 3/4" --

L-1 LAVATORY COUNTER MOUNTED, VITREOUS

CHINA, 3-HOLE PUNCH, 4-INCH

CENTERS, ROUND, FRONT OVERFLOW

KOHLER K-2095-4 FAUCET: SLOAN ETF-600 BDT WITH ETF-233

TRANSFORMER. SEE PLUMBING DEVICES

SCHEDULE FOR MIXING VALVE(S).

1-1/2" 1-1/2" 1/2" 1/2"

L-2 LAVATORY WALL MOUNTED, VITREOUS CHINA,

3-HOLE PUNCH, 4-INCH CENTERS,

FRONT OVERFLOW

KOHLER K-2500 FAUCET: SLOAN ETF-600 BDT WITH ETF-233

TRANSFORMER. SEE PLUMBING DEVICES

SCHEDULE FOR MIXING VALVE(S).

1-1/2" 1-1/2" 1/2" 1/2"

MS-1 MOP SINK FLOOR MOUNTED, TERRAZZO,

24-INCHES X 24-INCHES X 10-INCHES

STERN

WILLIAMS

CRS-2200 FAUCET (MOP SINK): DELTA C 28C2383 WITH

INTEGRAL CHECKS

3" 2" 1/2" 1/2"

S-1 SINK COUNTERTOP, SINGLE BOWL, 18

GAUGE STAINLESS STEEL, 15-INCHES

X 17-1/2-INCHES X 7-5/8-INCHES DEEP,

18-INCH MINIMUM CABINET SIZE,

3-HOLE PUNCH

ELKAY LR1517-3 FAUCET (8-INCH GOOSENECK WRISTBLADE):

CHICAGO 201-AGN8AE36-317ABCP

2" 1-1/2" 1/2" 1/2"

SH-1 SHOWER BARRIER FREE, ONE PIECE, 62-INCHES

X 36-1/4-INCHES X 77-1/4-INCHES, SLIP

RESISTANT TEXTURED BOTTOM,

SHOWER CURTAIN AND ROD, ONE 24"

GRAB BAR AND ONE 30" GRAB BAR,

L-SHAPED FOLD UP SEAT, 3/4-INCH

THRESHOLD

FIBER FABS FAUCET: SYMMONS 1-100 SAFETYMIX. FIBER

FABS #36

2" 1-1/2" 1/2" 1/2" PROVIDE WITH

OPTIONS AS

LISTED IN

DESCRIPTION

SH-2 SHOWER ONE PIECE, 37-1/4-INCHES X

36-INCHES X 79-1/4-INCHES,

SLIP-RESISTANT TEXTURED BOTTOM,

SHOWER CURTAIN AND ROD

FIBER FABS FAUCET: SYMMONS 1-117-FS-X W/ 60"

FLEXIBLE HOSE. FIBER FAB #38 H1 WITH LOW

PROFILE BOTTOM.

2" 1-1/2" 1/2" 1/2"

U-1 URINAL WALL MOUNTED, VITREOUS CHINA,

TOP SPUD, FLUSHOMETER,

STANDARD MOUNTING HEIGHT

KOHLER K4960-ET FLUSH VALVE ( BATTERY - 0.125 GPF,

DIAPHRAGM): SLOAN 186-0.5-ES-2 W/ EL-154

TRANSFORMER

2" 1-1/2" 3/4" --

WC-1 WATER CLOSET FLOOR MOUNTED, VITREOUS CHINA,

TOP SPUD, FLUSHOMETER,

STANDARD HEIGHT

CAROMA CARAVELLE

FLUSH VALVE (BATTERY - 1.28 GPF,

DIAPHRAGM): SLOAN 8111-1.28

SEAT: CARAVELLE COM. ELONG.: 326013

4" 2" 1" --

WC-2 WATER CLOSET FLOOR MOUNTED, VITREOUS CHINA,

TOP SPUD, FLUSHOMETER, BARRIER

FREE HEIGHT

CAROMA CARAVELLE

FLUSH VALVE (BATTERY - 1.28 GPF,

DIAPHRAGM): SLOAN 8111-1.28

SEAT: CARAVELLE COM. ELONG.: 326013

4" 2" 1" --

NOTES:

PLUMBING FIXTURE SCHEDULE

BASIS OF DESIGN CONNECTION

SEE ARCHITECTURAL DRAWINGS FOR ALL FIXTURE MOUNTING HEIGHTS AND LOCATIONS.

UNLESS NOTED OTHERWISE ON DRAWINGS

GAS DATA

TP-1 TRAP PRIMER PRECISION PLUMBING

PRODUCTS

MP-500 120 1 2 6.3 --- CONTROLLER INCLUDES CIRCUIT BREAKER, MANUAL

SWITCH, AND TIME CLOCK. SERVES 1 TO 4 DRAINS.

NOTES:

MISCELLANEOUS EQUIPMENT SCHEDULE

SYMBOL EQUIPMENT TYPE LOCATION / SERVING

BASIS OF DESIGN

CAPACITY

ELECTRICAL

COMMENTSMFR MODEL

INPUT

(MBH) VOLTS PH AMPS WATTS HP

CP-1 DOMESTIC HOT WATER

CIRCULATING PUMP

STORAGE 107 /

DOMESTIC HOT WATER

GRUNDFOS SERIES UP

26-96 SF

5 24 ___ 230 1 0.8 205 ___

NOTES:

PUMP SCHEDULE

SYMBOL EQUIPMENT TYPE LOCATION / SERVING

BASIS OF DESIGN

FLOW

RATE (GPM)

HEAD (FT

H2O) RPM

ELECTRICAL

COMMENTSMFR MODEL VOLTS PH AMPS WATTS HP

NO. OF BTU/HR TOTAL

FIXTURE DESCRIPTION FIXT. INPUT BTU/HR

MECHANICAL EQUIPMENT

AHU-1 AIR HANDLING UNIT 1 800,000 800,000

AHU-2 AIR HANDLING UNIT 1 800,000 800,000

AHU-3 AIR HANDLING UNIT 1 800,000 800,000

AHU-4 AIR HANDLING UNIT 1 620,000 620,000

PLUMBING EQUIPMENT

GWH-1 DOMESTIC WATER HEATER 1 199,000 199,000

TOTAL DEMAND (BTU) 3,219,000

TOTAL DEMAND (CFH) 3,219

GAS: NATURAL GAS

PIPING: SCH 40 STEEL

SIZING BASED ON:

2 PSI SUPPLY PRESSURE WITH 1 PSI PRESSURE DROP

550 FEET DEVELOPED LENGTH

4" 23,200 CFH

3" 11,400 CFH

2-1/2" 6,430 CFH

2" 4,030 CFH

1 1/2" 2,090 CFH

1 1/4" 1,400 CFH

1" 681 CFH

3/4" 381 CFH

1/2" 182 CFH

GAS CALCULATIONS

OREGON MECHANICAL SPECIALTY CODE

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

EXPIRES: 12/31/23

/1

/2

:1

:5

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

CG

P701

SCHEDULES -

PLUMBING

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

PROVIDE PRESSURE REGULATOR

VENT AS REQUIRED

PRESSURE

REGULATOR

CAP

FLEX

CONNECTOR.

REFER TO

SPECIFICATIONS.

MINIMUM DISTANCE EQUAL

TO 10 PIPE DIAMETERS

SUPPLY PIPING

NATURAL GAS

1/4" PIPE PLUG

UNION

(TYP. 2)

TO EQUIP.

SHUTOFF

VALVE

PRESSURE TEST

TEE

WITH 1/4" BRANCH

(TYPICAL)

DETAIL KEYNOTES

[GWH-1]

[CP-1]

G

S

DRAIN PAN.

FLUE.

HOT WATER

COLD WATER

HOT WATER RETURN

3/4"

1-1/4"

1. CONTRACTOR TO PROVIDE

TIMER, WIRING, CONDUIT,

SWITCH, AND INSTALLATION.

COORDINATE ELECTRICAL

POWER TO COMPONENTS WITH

DIVISION 16.

DISCHARGE

TO FS-1

U.L. LISTED ELECTRICAL

TIMER. 24 HOUR TYPE WITH

MANUAL BYPASS.

TORK 1100 SERIES

PROVIDE CONNECTION.

TO STORM SEWER

CLEAN OUT PLUG

WITH RAISED NUT.

4" 2"

BUILDING

FINISH.

DOWNSPOUT

BY OTHERS.

PROJECT NUMBER:

SHEET TITLE:

DRAWN BY:

CONSULTANT:

SHEET:

Suite 300 503.221.2077

Portland OR 97209 www.lrsarchitects.com

A R C H I T E C T S 720 NW Davis 503.221.1121

EXPIRES: 12/31/23

/1

/2

:1

:5

P

M C

R e v it P ro je c ts

\M E

P

C la c k a m a s F a ir g ro u n d s M

P v ra y m o n d c

.r v t

CG

P902

DETAILS -

PLUMBING

BID SET

CLACKAMAS

COUNTY

FAIRGROUNDS

MULTI-PURPOSE

BUILDING

694 NE 4TH AVENUE

CANBY, OR 97013

222033

5.05.2023

LRS Architects, Inc. © 2023

PROJECT

CONTACT

www.interfaceengineering.com

Ryan McClain 2022-0151

100 SW Main Street, Suite 1600 Portland, OR 97204

TEL 503.382.2266

NO SCALE

1 GAS REGULATOR VENT PIPING THRU ROOF

NO SCALE

2 GAS WATER HEATER

NO SCALE

3 DOWNSPOUT/STORM DRAIN CONNECTION

Sheets
P000 - SYMBOL LIST AND GENERAL NOTES - PLUMBING
P201 - OVERALL UNDERGROUND PLAN
P202 - OVERALL PLUMBING FLOOR PLAN
P203 - ENLARGED PLAN AND RISER - NORTHEASTERN PLUMBING UNDERGROUND
P204 - ENLARGED PLAN AND RISER - NORTHEASTERN PLUMBING
P205 - ENLARGED PLAN AND RISER - SOUTHEASTERN PLUMBING UNDERGROUND
P206 - ENLARGED PLAN AND RISER - SOUTHESTERN PLUMBING
P701 - SCHEDULES - PLUMBING
P902 - DETAILS - PLUMBING

File details come from the government source that posted it. Updated .