Attachment F - CCFEC-Bid-Docs-Drwgs-06-Plumb.pdf
PDF 2 MB Posted
- Solicitation number
- S-C01010-00007195
- Issued by
- Clackamas County, Canyonville City, Oregon
About this file
This document contains information related to a state and local contract opportunity for the Clackamas County Fairgrounds Multiuse Building Project. The County is accepting sealed bids until July 13, 2023 at 2:00 PM Pacific Time for this project. The project involves the construction of a multi-purpose building at the Clackamas County Fairgrounds located in Canby, Oregon. The bid documents include detailed plans and specifications for the plumbing work, including site plans, floor plans, riser diagrams, schedules, and details.
The bid documents provide extensive technical information about the plumbing systems and requirements, including details on pipe routing, fixture types and connections, water and gas piping, drainage and venting systems, and related equipment such as water heaters and pumps. The documents include detailed plumbing fixture and equipment schedules specifying manufacturer, model numbers, and connection sizes. Additionally, the documents contain gas piping sizing calculations and details for gas regulator vents.
View the file
Other files
Show all 22
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A CONDITIONS SHOW ON THE PLANS RELATIVE TO THE WORK TO BE
PERFORMED ARE BASED ON THE BEST INFORMATION AVAILABLE BUT ARE
SUBJECT TO VERIFICATION. VERIFY LOCATIONS AND ELEVATIONS OF
UTILITIES TO BE CROSSED OR CONNECTED. CORRECT DEFICIENCIES
CAUSED BY FAILURE TO PERFORM SUCH VERIFICATIONS AT NO EXPENSE TO
OWNER. IMMEDIATELY NOTIFY ARCHITECT AND ENGINEER OF CONDITION IN
CONFLICT WITH THE DETAILS/PLANS.
B PROVIDE GAS SHUTOFF VALVES, PRESSURE REGULATORS AND UNION
AT CONNECTIONS TO GAS-FIRED EQUIPMENT. PROVIDE REGULATOR RELIEF
VENT PIPING TO ATMOSPHERE WHERE REQUIRED BY CODE.
C COORDINATE INSTALLATION OF PIPING BELOW AND ABOVE GRADE WITH
STRUCTURAL COMPONENTS AND OTHER SYSTEMS INSTALLATION.
D COORDINATE FIXTURES, EQUIPMENT, PIPE ROUGH-IN/CONNECTION
LOCATIONS AND DRAIN LOCATIONS WITH ARCHITECTURAL DRAWINGS.
E ALL PIPING SYSTEMS CROSSING SEISMIC SEPARATIONS SHALL UTILIZE PRE-
MANUFACTURED EXPANSION JOINT SYSTEM, SIZED FOR 4 INCH X, Y AND Z
MOVEMENT. UNISOURCE 'V' TYPE, HYSPAN OR APPROVED.
F PIPING ROUTED THROUGH ROOF TO BE INSTALLED PER ARCHITECTURAL
REQUIREMENTS (SEE ARHICTECTURAL DETAILS).
G LOCATE ALL VTR A MINIMUM OF 10'-0" FROM OUTSIDE AIR OPENINGS OF
ROOFTOP HVAC EQUIPMENT.
H EXTERIOR HOSE BIBBS TO BE MOUNTED AT 24 INCHES ABOVE FINISH
GRADE (UNLESS SPECIFICALLY NOTED OTHERWISE).
I LOCATE VALVES FOR SERVICE ACCESSIBILITY. VALVES INSTALLED ABOVE
CEILING SHALL BE WITHIN 18" OF CEILING.
J INSTALL OVERHEAD PIPING AS CLOSE TO STRUCTURE AS POSSIBLE IN
AREAS WITH EXPOSED ROOF STRUCTURE.
K REFER TO SPECIFICATIONS FOR SEISMIC RESTRAINT REQUIREMENTS FOR
PIPING AND EQUIPMENT.
L DOWNSPOUT RISERS AND STORM DRAIN RISERS TO BE PROVIDED WITH
CLEANOUT AT BASE OF VERTICAL STACK. SIMILAR TO DETAILS
3/P902___
M PROVIDE CLEANOUTS FOR SANITARY WASTE AND STORM DRAINAGE SYSTEMS
WHERE SHOWN AND AS OTHERWISE REQUIRED BY CODE.
N VERIFY LOCATIONS OF CONNECTIONS TO PIPING INSTALLED BY
SITE CONTRACTOR.
O PIPING INSTALLED IN EXTERIOR WALLS TO BE INSTALLED ON WARM
SIDE OF INSULATION.
P FURNISH AND INSTALL VALVES, TRAPS, STRAINERS, BACK FLOW PREVENTERS,
ETC. NOT FURNISHED BY EQUIPMENT SUPPLIER, BUT REQUIRED
FOR PROPER EQUIPMENT OPERATION.
Q SHUT-OFF VALVES TO BE INSTALLED IN ALL WATER AND GAS PIPING AT
LOCATIONS SHOWN. PROVIDE ACCESS PANELS IF CEILING
AND STRUCTURAL CONDITIONS DO NOT ALLOW NORMAL ACCESS.
COORDINATE EXACT TYPE AND LOCATION WITH OWNER AND GENERAL
CONTRACTOR PRIOR TO ROUGH-IN.
R CONTRACTOR TO PROVIDE LOCATE/SCOPING SERVICES FOR EXISTING
PIPING BELOW GRADE AND DOCUMENT/RECORD, COORDINATE WITH
NEW WORK PRIOR TO START OF CONSTRUCTION.
S ROOF PENETRATIONS TO BE MINIMUM 5'-0" CLEAR OF
TWO HOUR WALL SEPARATIONS.
T SEE PLUMBING FIXTURE SCHEDULE FOR PIPE CONNECTION SIZES.
U COORDINATE INSTALLATION OF DUCTWORK, PIPING, FIXTURES, EQUIPMENT, ETC.
WITH ARCHITECTURAL, STRUCTURAL, MECHANICAL, ELECTRICAL AND FIRE
PROTECTION SYSTEMS PRIOR TO INSTALLATION.
V REFER TO ARCHITECTURAL DRAWINGS FOR ADA ACCESSIBILITY REQUIREMENTS.
W PROVIDE CEILING ACCESS PANELS FOR VALVES LOCATED ABOVE
INACCESSIBLE CEILING SYSTEMS. VALVES INSTALLED ABOVE CEILING SHALL BE
WITHIN 18" OF CEILING. MAINTAIN FIRE RATINGS WHERE REQUIRED.
X SEE ARCHITECTURAL DRAWINGS FOR EXACT FIXTURE LOCATIONS.
Y REFER TO SPECIFICATIONS FOR SEISMIC RESTRAINT
REQUIREMENTS FOR PIPING/EQUIPMENT.
GENERAL NOTES
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
EXPIRES: 12/31/23
/1
/2
:1
:4
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
CG
P000
SYMBOL LIST
AND GENERAL
NOTES -
PLUMBING
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
P000 SYMBOL LIST AND GENERAL NOTES - PLUMBING
P201 OVERALL UNDERGROUND PLAN
P202 OVERALL PLUMBING FLOOR PLAN
P203 ENLARGED PLAN AND RISER - NORTHEASTERN PLUMBING
UNDERGROUND
P204 ENLARGED PLAN AND RISER - NORTHEASTERN PLUMBING
P205 ENLARGED PLAN AND RISER - SOUTHEASTERN PLUMBING
UNDERGROUND
P206 ENLARGED PLAN AND RISER - SOUTHESTERN PLUMBING
P701 SCHEDULES - PLUMBING
P902 DETAILS - PLUMBING
SHEET INDEX
PLUMBING SYMBOL LIST
NOTE: This is a standard symbol list and not all items listed may be used.
General
CONTINUATION
EQUIPMENT IDENTIFICATION
EXTENT OF DEMOLITION
FIXTURE TAG (LEVEL BELOW FIXTURE)
KEYED NOTE
POINT OF CONNECTION
DEMOLISH
EXISTING WORK
NEW WORK
PIPE OR CONDUIT BELOW GRADE
Piping Fittings
ACCESS PANEL
AQUASTAT
BLIND FLANGE
CAP
CLEANOUT TO GRADE
CONCENTRIC REDUCER
DOWNSPOUT NOZZLE
ECCENTRIC REDUCER
FLOOR CLEANOUT
FLOOR DRAIN
FLOOR SINK
FLOW DIRECTION
HOSE BIBB / WALL HYDRANT
OVERFLOW ROOF DRAIN
PIPE DROP
PIPE RISE
PUMP
ROOF DRAIN
SHOCK ABSORBER / WATER HAMMER ARRESTOR
STRAINER
T&P RELIEF VALVE WITH PIPE TO DRAIN
TEE DOWN ON PIPE
TEE UP ON PIPE
VENT THROUGH ROOF
WALL CLEANOUT
Piping Systems
COLD WATER PIPING
CONDENSATE / INDIRECT DRAIN PIPING
HOT WATER PIPING
HOT WATER RETURN PIPING
NATURAL GAS PIPING, 2 LB
NATURAL GAS PIPING, 7" WC PRESSURE
OVERFLOW DRAIN PIPING ABOVE GRADE OR FINISHED FLOOR
SANITARY VENT PIPING
Abbreviations
(A) ABANDON IN PLACE
AFF ABOVE FINISHED FLOOR
AP ACCESS PANEL
& AND
A AQUASTAT, ARCHITECT, ANCHOR, AMPHERE
@ AT
BFP BACKFLOW PREVENTER
BFF BELOW FINISHED FLOOR
BTUH BRITISH THERMAL UNITS PER HOUR
BLDG BUILDING
CV CHECK VALVE
CO CLEANOUT
CW COLD WATER
CD CONDENSATE DRAIN
CONT. CONTINUATION
CFH CUBIC FEET PER HOUR
CFS CUBIC FEET PER SECOND
(X) DEMOLISH
DW DISHWASHER, DOMESTIC WATER
DET DOMESTIC EXPANSION TANK
DCVA DOUBLE CHECK VALVE ASSEMBLY
DN DOWN
DS DOWNSPOUT
DSN DOWNSPOUT NOZZLE
D DRAIN
DFU DRAINAGE FIXTURE UNIT
DWV DRAINAGE, WASTE AND VENT
DF DRINKING FOUNTAIN
EWC ELECTRIC WATER COOLER
EWH ELECTRIC WATER HEATER
(E) EXISTING
FT FEET
FFE FINISHED FLOOR ELEVATION
F FIRE, FAHRENHEIT
FL FLOOR
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FV FLUSH VALVE
' FOOT, FEET
(F) FUTURE
GPM GALLONS PER MINUTE
GWH GAS WATER HEATER
HVAC HEATING, VENTILATING AND AIR CONDITIONING
HZ HERTZ
HB HOSE BIBB
HW HOT WATER
HWFU HOT WATER FIXTURE UNIT
HWR HOT WATER RETURN
IN, " INCHES
IW INDIRECT WASTE
INV INVERT ELEVATION
L LAVATORY
MIN MINIMUM
MX MIXING VALVE
MS MOP SINK
(N) NEW
N NORTH
NIC NOT IN CONTRACT
NTS NOT TO SCALE
# NUMBER
NO. NUMBER
OD OVERFLOW DRAIN, OUTSIDE DIAMETER
OFCI OWNER FURNISHED, CONTRACTOR INSTALLED
OFOI OWNER FURNISHED, OWNER INSTALLED
PLBG PLUMBING
P PLUMBING, PUMP
POC POINT OF CONNECTION
PSI POUNDS PER SQUARE INCH
PD PRESSURE DROP, PLUMBING DEMOLITION, PUMPED DISCHARGE
PRV PRESSURE REDUCING VALVE
QTY QUANTITY
RWL RAINWATER LEADER
RPBP REDUCED PRESSURE BACKFLOW PREVENTER
(R) RELOCATE / RELOCATED LOCATION
RD ROOF DRAIN
SAN SANITARY
SB SERVICE BOX
SHT SHEET
SA SHOCK ARRESTOR
SOV SHUT OFF VALVE
S, SK SINK
SF SQUARE FEET
SD STORM DRAIN
SP SUMP PUMP, STATIC PRESSURE
TEMP TEMPERATURE
TP TRAP PRIMER, TOTAL PRESSURE
TYP TYPICAL
U, UR URINAL
V VACUUM, VENT, VOLT
VTR VENT THRU ROOF
WCO WALL CLEANOUT
W WASTE
WC WATER COLUMN, WATER CLOSET
WHA WATER HAMMER ARRESTOR
WH WATER HEATER, WALL HYDRANT
WSFU WATER SUPPLY FIXTURE UNIT
W/ WITH
SANITARY WASTE OR SOIL PIPING ABOVE GRADE OR FINISHED
FLOOR
SANITARY WASTE OR SOIL PIPING BELOW GRADE OR FINISHED
FLOOR
STORM DRAIN PIPING ABOVE GRADE OR FINISHED FLOOR
STORM DRAIN PIPING BELOW GRADE OR FINISHED FLOOR
TRAP PRIMER PIPING
Valves
BACKFLOW PREVENTER
CHECK VALVE
SHUTOFF VALVE, GENERAL
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
P203
P205
1 2 3 4 5 6 7 8 9 10 11 12
B
A
C
4" DS-1
(7,400 SQFT)
1 4" DS-1
(7,400 SQFT)
4" DS-1
(7,400 SQFT)
3" DS-1
(4,200 SQFT)
3" DS-1
(4,200 SQFT)11
3" DS-1
(4,200 SQFT)11
3" DS-1
(4,200 SQFT)
3" DS-1
(4,200 SQFT)
3" DS-1
(4,200 SQFT)
2" DS-1
(300 SQFT)
2" DS-1
(300 SQFT)
FD-1 FD-1 FD-1 FD-1 FD-1 FD-1 FD-1 FD-1
FCO
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
EXPIRES: 12/31/23
/1
/2
:1
:4
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
CG
P201
OVERALL
UNDERGROUND
PLAN
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 8' 16' 32'
1/16" = 1'-0"
1 UNDERGROUND PLAN - PLUMBING N
O R T H
SHEET KEYNOTES
1. SEE CIVIL FOR CONTINUATION AND SEE DETAIL 3/P902 FOR DETAIL.
P204
P206
1 1/4" G 1" G
1 1/2" G
1 1/4" G
1 1/4" G
1 1/2" G
1 2 3 4 5 6 7 8 9 10 11 12
B
A
C
AHU-03
AHU-04
AHU-02
AHU-01
1 1/2" G
3 2
1" CW
1" CW
1" CW1" CW
3/4" CW
HB-1
HB-1
HB-1 HB-1 HB-1
HB-1
1 1 1
HB-11 HB-113/4" CW 1" CW 1" CW
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
EXPIRES: 12/31/23
/1
/2
:1
:5
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
CG
P202
OVERALL
PLUMBING
FLOOR PLAN
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 8' 16' 32'
1/16" = 1'-0"
1 FIRST FLOOR PLAN - PLUMBING N
O R T H
SHEET KEYNOTES
1. ROUTE 3/4" PIIPNG DOWN TO HOSE BIBBS AND MOUNT HOSE BIBBS AT 24" AFF.
2. ROUTE PIPING IN MEZZANINE AGAINST AND ENSURE IT IS WITHIN SAFE CLEARANCE TO ANY OTHER
EQUIPMENT. ROUTE PIPING AROUND ANY STRUCTURAL ELEMENTS.
3. ROUTE PIPING DOWN TO 24" AFF AND OUT TO EQUIPMENT. SEE DETAIL 1/P902 FOR GAS CONNECTION DETAIL.
FCO
WC
WC
WC
WC
L
WC
L
WC
L
FCO
FCO
S
S
S
S
SH SH
CO
C W
L
10 11 12
A
WC
WC
S A
N
2" SAN
S A
N
SH
2" V
FD
2%
2%
4" SAN
4" SAN
S A
N
S A
N
S A
N
S A
N
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
4" SAN
FCO
2" SAN
S-1
S-1
S-1
S-1
WC-1
L-1
L-1
L-1
L-1
L-1
L-1
L-1
L-1
L-1
WCO
FCO
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1 WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
4" S
AN
4" S
AN
FD-1
WC-2
L-1
WC-2
WC-2
SH-1
SH-1
SH-1
FCO
2" V
1 1/2" V
2" V
2" V
V
V
2" V
S A
N
6" S
AN
4" SAN
2" SAN
4" S
AN
4" S
AN
4" S
AN
3" V
2" V
V
V
V 3
V
V
FCO
FCO
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
EXPIRES: 12/31/23
/1
/2
:1
:5
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
RM
P203
ENLARGED PLAN
AND RISER -
NORTHEASTERN
PLUMBING
UNDERGROUND
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 4' 8' 16'
1/4" = 1'-0"
1 ENLARGED NORTHEASTERN UNDERGROUND PLAN - PLUMBING 2 NORTHEAST SANITARY RISER DIAGRAM
SHEET KEYNOTES
1. SEE CIVIL FOR CONTINUATION.
2. ROUTE VENT THRU ROOF LINES SEPARATELY TO ROOF AND AROUND SOLAR PANELS.
N O R T H
2 2 2 2
L-2
S-1
FIRE RISER
STORAGE
ELEC.
W SHOWERS
MECH.
10 11 12
A
WCO
S-1
S-1
S-1
SH-1
SH-1
L-1
L-1
L-1
L-1L-1
L-1
L-1
L-1
FCO
L-1
3/4" HW
3/4" HW
3/4" HWR
3/4" HWR
/4
H
W R
1" HW
1" CW 2" CW 2" CW
2" CW
/4
H
W
/4
H
W
H W
H W
R
C W
H W
/4
H
W R
/4
H
W R
3/4" HW
3/4" CW
3/4" HWR
C W
2 1/2" CW
2" CW
2 1/2" CW
2" CW
C W
C W
2" V
2" V
2" V
2" V
3" V
2" V
2" V
2" V
2" V
W SHOWERS
WELLNESS
WOMENS RR
RR
LOBBY
4" CW
FD-1
FCU-01
FCU-02
3/4" CW 3/4" HW
WC-2
1 1/2" V 2" V
FCO
FCO
FCO
3/4" D
3/4" D
1 1/2" G
/2
G
1 1/2" G
SH-1
WC-2
WC-2
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1 WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-2
C W
2 1/2" CW
1" CW
1" CW
HB-1
S-1 S-1
S-1
S-1
SH-1
SH-1
WC-1
L-1
L-1
L-1
L-1
L-1 L-1
WC-2
L-1
L-1
L-1
L-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-2
WC-2
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-1
1" HW
1" HWR
3" C W
2 1/2" CW
2 1/2" CW
2" C W
2" C W
4" C W
4" CW
C W
4" C W
3/4" H W
R
2" C W
1/2" H W
1/2" H W
R
3/4" H W
3/4" H W
2" CW
3/4" HW
1" CW
3/4" HWR
3/4" HW
1" HW
1" H W3/4" H W
R
3" C W
3" CW
1" HW
R1" HW
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
EXPIRES: 12/31/23
/1
/2
:1
:5
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
RM
P204
ENLARGED PLAN
AND RISER -
NORTHEASTERN
PLUMBING
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 4' 8' 16'
1/4" = 1'-0"
1 ENLARGED NORTHEASTERN PLAN - PLUMBING 2 NORTHEASTERN DOMESTIC WATER RISER DIAGRAM
SHEET KEYNOTES
1. BALANCING VALVE, SET TO 0.5GPM.
2. 3" VTR TRHOUGH ROOF. VERIFY LOCATION OF FUTURE SOLAR PANELS BEFORE INSTALLING.
N O R T H
L
L
U
U
WC
FCO
FCO
FCO
CO
DF
FCO
FS
2" G UP TO METER
S A
N
4" SAN
S A
N
S A
N
IE: 62" BFF
10 11 12
C
SH
SH
SH
CO
MS
S A
N
CO
S A
N
6" SAN
S A
N
S A
N
S A
N
FS-1
FCO
FCO
6" S
AN
4" SAN
4" S
AN
DF-1
DF-1
DF-1
SH-2
SH-2
SH-1
WC-1
WC-1
WC-1
WC-1
WC-1
WC-2
L-1
L-1 L-1
L-1
L-1
L-1
L-1
L-1
WCO
MS-1
6" S
AN
6" SAN
4" S
AN
4" SAN
6" S
AN
4" SAN
4" S
AN
3" V
V
3" V
1 1/2" V
2" V
3" V
2" V
WCO
U-1
U-1
U-1
FCO
FCO
FS-1
U-1
U-1
U-1
U-1
U-1
FCO
FCO
WCO
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
EXPIRES: 12/31/23
/1
/2
:1
:5
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
RM
P205
ENLARGED PLAN
AND RISER -
SOUTHEASTERN
PLUMBING
UNDERGROUND
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 4' 8' 16'
1/4" = 1'-0"
1 UNDERGROUND PLAN - PLUMBING 2 SOUTHEAST SANITARY RISER DIAGRAM
SHEET KEYNOTES
1. SEE CIVIL FOR CONTINUATION.
2. ROUTE VENT THRU ROOF LINES SEPARATELY TO ROOF AND AROUND SOLAR PANELS.
N O R T H
2 2
L-1
L-1
L-1
L-1
U-1
U-1
GWH-1
2 1/2" CW
DF-1
MENS RR
STORAGE
JANITOR
106A
OFFICE
L-1
L-1
L-1
L-1
U-1
U-1
U-1
U-1
U-1
U-1
WCO
FCO
FS-1
FCO
C W
NATURAL GAS METER,
2PSI
11 12
C
WCO
H W
R
H W
C W
H W
R
H W
CP-1
3/4" HW
3/4" CW
3/4" HWR
2" CW
2" CW
2 1/2" CW
1 1/4" CW
3/4" HW
3/4" HWR
1" HW
1" HWR
3" CW
C W
2" CW
V
1 1/2" CW
1 1/2" CW
2 1/2" CW
2" CW
DF-1
DF-1
SH-1
FCO
2" V
SH-2
SH-2
1 1/4" CW
1 1/2" G
3" V
WC-1
WC-1
WC-1
WC-1
WC-1
WC-2
MS-1
2" G
1" CW
/2
G
WCO
P902
1 1/2" G
HB-1
STORAGE
G
SH-1
SH-2
SH-2
U-1
U-1
U-1
U-1
U-1
U-1
U-1
U-1
1" C W
2" CW
2 1/2" CW
1 1/4" CW 3" C
W
1" HW
1" HWR
2" CW
2" CW
2" C W
2 1/2" CW
1" CW 3/4" HW
3/4" CW
3/4" CW
3/4" HW
3/4" HWR
3/4" HWR
3" CW
1" HW
1" HWR
DF-1
DF-1
DF-1
3/4" H W
R
GWH-1
CP-1
WC-2
WC-1 WC-1
WC-1
WC-1
WC-1
L-1
L-1
L-1
L-1
L-1
L-1
L-1
L-1
MS-1
3/4" HW
R3/4" HW
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
/1
/2
:1
:5
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
RM
P206
ENLARGED PLAN
AND RISER -
SOUTHESTERN
PLUMBING
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
0' 4' 8' 16'
1/4" = 1'-0"
1 ENLARGED SOUTHEASTERN PLAN - PLUMBING
0' 4' 8' 16'
2 SOUTHEAST DOMESTIC WATER RISER DIAGRAM
SHEET KEYNOTES
1. BALANCING VALVE, SET TO 0.5GPM.
2. 3" VTR TRHOUGH ROOF. SEE 2/P205 FOR ROUTING AROUND SOLAR PANELS.
N O R T H
EXPIRES: 12/31/23
SYMBOL FIXTURE TYPE DESCRIPTION MFR MODEL ACCESSORIES W V CW HW NOTES
LMV-1 LAVATORY MIXING
VALVE
THERMOSTATIC MIXING VALVE, ASSE
1070 COMPLIANT, INTEGRAL CHECK
VALVES, LEAD FREE, CHROME
SLOAN 3326009 --- --- 1/2" 1/2"
MMV-1 MASTER MIXING
VALVE
FULL PACKAGE SYSTEM WITH
HIGH/LOW FLOW MIXING VALVES,
GAUGES, PRV(S), VALVES, UNIONS
AND OTHER CONNECTIONS,
EXPOSED. 1 GPM TO 72 GPM AT 45
PSI MAX FALLOFF. SYSTEM PEAK =
39 GPM.
LEONARDTM-186-5015-PRV-RF-0 --- --- 3/4" 3/4"
NOTES:
PLUMBING DEVICES SCHEDULE
BASIS OF DESIGN CONNECTION
GAS DATA
GWH-1 WATER HEATER STORAGE 107 / DOMESTIC HOT
WATER
AO SMITH BTH-199 100 199 120 1 4 PROPANE-FIRED, BOILER, CONDENSING, DIRECT VENTING.
95% HIGH EFFICIENCY. [ASME] 5.6 GPM FLOW RATE AT 67F
TEMPERATURE RISE.
NOTES:
WATER HEATER SCHEDULE
SYMBOL EQUIPMENT TYPE LOCATION / SERVING
BASIS OF DESIGN TANK
CAPACITY
(GALLONS)
ELECTRICAL
COMMENTSMFR MODEL
INPUT
(MBH) VOLTS PH AMPS KW
FIXTURE QUANTITY FIXTURE QUANTITY TABLE 703.2 TABLE 703.2
PRIVATE PUBLIC PRIVATE PUBLIC TOTAL
INDIVIDUAL INDIVIDUAL INDIVIDUAL FIXTURE
DWELLING DESCRIPTION DWELLING DWELLING UNITS
0 4 SINK 2.00 2.00 8.00
0 18 LAVATORY, SINGLE 1.00 1.00 18.00
0 6 SHOWER, STALL, 2" TRAP 2.00 2.00 12.00
0 28 WATER CLOSET, 1.28 GPF, FLUSHMETER VALVE 3.00 4.00 112.00
0 3 DRINKING FOUNTAIN 0.50 0.50 1.50
0 1 MOP SINK -- 3.00 3.00
0 9 FLOOR DRAIN -- 4.00 36.00
0 1 FLOOR SINK -- 4.00 4.00
194.50
MINIMUM PIPE SIZE 6.00
SANITARY DRAINAGE
CALCULATIONS
PRIVATE PUBLIC PRIVATE PUBLIC
INDIVIDUAL USE INDIVIDUAL USE COLD
DWELLING DESCRIPTION DWELLING WATER
APPENDIX A SIZING WATER SUPPLY SYSTEM
0 1 HOSE BIBB 2.50 2.50 2.50
0 9 HOSE BIBB, EACH ADDITIONAL 1.00 1.00 9.00
0 18 LAVATORY 1.00 1.00 18.00
0 4 SINKS 1.50 1.50 6.00
0 6 SHOWER, PER HEAD 2.00 2.00 12.00
0 28 WATER CLOSET, 1.28 GPF, FLUSH VALVE 5.00 5.00 140.00
0 1 MOP SINK 1.50 3.00 3.00
0 3 DRINKING FOUNTAIN 0.50 0.50 1.50
TOTAL: 190.50
FLOW (GPM): 89.00
a MINIMUM DAILY SERVICE PRESSURE 58 b WATER METER PRESSURE DROP 5 c BACKFLOW PREVENTER 7
d. STATIC HEAD LOSS 25 FT X .434 /FT 13.02
e. PRESSURE REQUIRED AT FIXTURE 30
PRESSURE AVAILABLE FOR
FRICTION LOSS, a - b - c - d - e 2.98
400 TOTAL EQUIVALENT PIPE LENGTH
LENGTH X 1.25 500
MAXIMUM FRICTION LOSS
PRESS. AVAIL. X 100'/EQUIV. LENGTH 0.60
SERVICE SIZE FROM METER TO BUILDINGS 4
WATER SERVICE CALCULATIONS
2021 OREGON PLUMBING SPECIALTY CODE
QTY TOTAL FIXTURE UNITS
DOMESTIC WATER
SYMBOL FIXTURE TYPE DESCRIPTION MFR MODEL ACCESSORIES W V CW HW NOTES
DF-1 DRINKING FOUNTAIN WALL MOUNTED, DOUBLE BOWL, 18
GAUGE STAINLESS STEEL, SATIN
FINISH, VANDAL RESISTANT BUBBLER,
FRONT PUSHBUTTON. PROVIDE WITH
WALL PLATE
SUNROC ADA8ACB-STN 1-1/2" 1-1/2" 1/2" --
DS-1 DOWNSPOUT BOOT CAST IRON BODY AND STRAP, 4-INCH
ROUND
JR SMITH 1787 4" -- -- --
FD-1 FLOOR DRAIN
(UNFINISHED FLOORS /
MECHANICAL ROOMS)
CAST IRON BODY, FLASHING COLLAR,
8-1/2-INCH ROUND ADJUSTABLE TOP,
BAR GRATE, SEDIMENT BUCKET, TRAP
PRIMER
JR SMITH 2350Y-
P050
3"* 1-1/2"*PRIMER CONN. --
FS-1 FLOOR SINK CAST IRON FLANGED RECEPTOR,
SEEPAGE HOLES, ACID RESISTANT
COATED INTERIOR, NICKEL BRONZE
RIM, 1/2-GRATE, ALUMINUM DOME
BOTTOM STRAINER, 6-INCH DEEP
JR SMITH 3140Y-12 3"* 1-1/2"*PRIMER CONN. --
HB-1 HOSE BIBB ENCASED, NON-FREEZE, ANTI-SIPHON,
AUTOMATIC DRAINING, CHROME
PLATED BOX/DOOR ASSEMBLY,
DOUBLE CHECK BACKFLOW
PREVENTER
WOODFORD B67-P -- -- 3/4" --
L-1 LAVATORY COUNTER MOUNTED, VITREOUS
CHINA, 3-HOLE PUNCH, 4-INCH
CENTERS, ROUND, FRONT OVERFLOW
KOHLER K-2095-4 FAUCET: SLOAN ETF-600 BDT WITH ETF-233
TRANSFORMER. SEE PLUMBING DEVICES
SCHEDULE FOR MIXING VALVE(S).
1-1/2" 1-1/2" 1/2" 1/2"
L-2 LAVATORY WALL MOUNTED, VITREOUS CHINA,
3-HOLE PUNCH, 4-INCH CENTERS,
FRONT OVERFLOW
KOHLER K-2500 FAUCET: SLOAN ETF-600 BDT WITH ETF-233
TRANSFORMER. SEE PLUMBING DEVICES
SCHEDULE FOR MIXING VALVE(S).
1-1/2" 1-1/2" 1/2" 1/2"
MS-1 MOP SINK FLOOR MOUNTED, TERRAZZO,
24-INCHES X 24-INCHES X 10-INCHES
STERN
WILLIAMS
CRS-2200 FAUCET (MOP SINK): DELTA C 28C2383 WITH
INTEGRAL CHECKS
3" 2" 1/2" 1/2"
S-1 SINK COUNTERTOP, SINGLE BOWL, 18
GAUGE STAINLESS STEEL, 15-INCHES
X 17-1/2-INCHES X 7-5/8-INCHES DEEP,
18-INCH MINIMUM CABINET SIZE,
3-HOLE PUNCH
ELKAY LR1517-3 FAUCET (8-INCH GOOSENECK WRISTBLADE):
CHICAGO 201-AGN8AE36-317ABCP
2" 1-1/2" 1/2" 1/2"
SH-1 SHOWER BARRIER FREE, ONE PIECE, 62-INCHES
X 36-1/4-INCHES X 77-1/4-INCHES, SLIP
RESISTANT TEXTURED BOTTOM,
SHOWER CURTAIN AND ROD, ONE 24"
GRAB BAR AND ONE 30" GRAB BAR,
L-SHAPED FOLD UP SEAT, 3/4-INCH
THRESHOLD
FIBER FABS FAUCET: SYMMONS 1-100 SAFETYMIX. FIBER
FABS #36
2" 1-1/2" 1/2" 1/2" PROVIDE WITH
OPTIONS AS
LISTED IN
DESCRIPTION
SH-2 SHOWER ONE PIECE, 37-1/4-INCHES X
36-INCHES X 79-1/4-INCHES,
SLIP-RESISTANT TEXTURED BOTTOM,
SHOWER CURTAIN AND ROD
FIBER FABS FAUCET: SYMMONS 1-117-FS-X W/ 60"
FLEXIBLE HOSE. FIBER FAB #38 H1 WITH LOW
PROFILE BOTTOM.
2" 1-1/2" 1/2" 1/2"
U-1 URINAL WALL MOUNTED, VITREOUS CHINA,
TOP SPUD, FLUSHOMETER,
STANDARD MOUNTING HEIGHT
KOHLER K4960-ET FLUSH VALVE ( BATTERY - 0.125 GPF,
DIAPHRAGM): SLOAN 186-0.5-ES-2 W/ EL-154
TRANSFORMER
2" 1-1/2" 3/4" --
WC-1 WATER CLOSET FLOOR MOUNTED, VITREOUS CHINA,
TOP SPUD, FLUSHOMETER,
STANDARD HEIGHT
CAROMA CARAVELLE
FLUSH VALVE (BATTERY - 1.28 GPF,
DIAPHRAGM): SLOAN 8111-1.28
SEAT: CARAVELLE COM. ELONG.: 326013
4" 2" 1" --
WC-2 WATER CLOSET FLOOR MOUNTED, VITREOUS CHINA,
TOP SPUD, FLUSHOMETER, BARRIER
FREE HEIGHT
CAROMA CARAVELLE
FLUSH VALVE (BATTERY - 1.28 GPF,
DIAPHRAGM): SLOAN 8111-1.28
SEAT: CARAVELLE COM. ELONG.: 326013
4" 2" 1" --
NOTES:
PLUMBING FIXTURE SCHEDULE
BASIS OF DESIGN CONNECTION
SEE ARCHITECTURAL DRAWINGS FOR ALL FIXTURE MOUNTING HEIGHTS AND LOCATIONS.
UNLESS NOTED OTHERWISE ON DRAWINGS
GAS DATA
TP-1 TRAP PRIMER PRECISION PLUMBING
PRODUCTS
MP-500 120 1 2 6.3 --- CONTROLLER INCLUDES CIRCUIT BREAKER, MANUAL
SWITCH, AND TIME CLOCK. SERVES 1 TO 4 DRAINS.
NOTES:
MISCELLANEOUS EQUIPMENT SCHEDULE
SYMBOL EQUIPMENT TYPE LOCATION / SERVING
BASIS OF DESIGN
CAPACITY
ELECTRICAL
COMMENTSMFR MODEL
INPUT
(MBH) VOLTS PH AMPS WATTS HP
CP-1 DOMESTIC HOT WATER
CIRCULATING PUMP
STORAGE 107 /
DOMESTIC HOT WATER
GRUNDFOS SERIES UP
26-96 SF
5 24 ___ 230 1 0.8 205 ___
NOTES:
PUMP SCHEDULE
SYMBOL EQUIPMENT TYPE LOCATION / SERVING
BASIS OF DESIGN
FLOW
RATE (GPM)
HEAD (FT
H2O) RPM
ELECTRICAL
COMMENTSMFR MODEL VOLTS PH AMPS WATTS HP
NO. OF BTU/HR TOTAL
FIXTURE DESCRIPTION FIXT. INPUT BTU/HR
MECHANICAL EQUIPMENT
AHU-1 AIR HANDLING UNIT 1 800,000 800,000
AHU-2 AIR HANDLING UNIT 1 800,000 800,000
AHU-3 AIR HANDLING UNIT 1 800,000 800,000
AHU-4 AIR HANDLING UNIT 1 620,000 620,000
PLUMBING EQUIPMENT
GWH-1 DOMESTIC WATER HEATER 1 199,000 199,000
TOTAL DEMAND (BTU) 3,219,000
TOTAL DEMAND (CFH) 3,219
GAS: NATURAL GAS
PIPING: SCH 40 STEEL
SIZING BASED ON:
2 PSI SUPPLY PRESSURE WITH 1 PSI PRESSURE DROP
550 FEET DEVELOPED LENGTH
4" 23,200 CFH
3" 11,400 CFH
2-1/2" 6,430 CFH
2" 4,030 CFH
1 1/2" 2,090 CFH
1 1/4" 1,400 CFH
1" 681 CFH
3/4" 381 CFH
1/2" 182 CFH
GAS CALCULATIONS
OREGON MECHANICAL SPECIALTY CODE
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
EXPIRES: 12/31/23
/1
/2
:1
:5
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
CG
P701
SCHEDULES -
PLUMBING
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
PROVIDE PRESSURE REGULATOR
VENT AS REQUIRED
PRESSURE
REGULATOR
CAP
FLEX
CONNECTOR.
REFER TO
SPECIFICATIONS.
MINIMUM DISTANCE EQUAL
TO 10 PIPE DIAMETERS
SUPPLY PIPING
NATURAL GAS
1/4" PIPE PLUG
UNION
(TYP. 2)
TO EQUIP.
SHUTOFF
VALVE
PRESSURE TEST
TEE
WITH 1/4" BRANCH
(TYPICAL)
DETAIL KEYNOTES
[GWH-1]
[CP-1]
G
S
DRAIN PAN.
FLUE.
HOT WATER
COLD WATER
HOT WATER RETURN
3/4"
1-1/4"
1. CONTRACTOR TO PROVIDE
TIMER, WIRING, CONDUIT,
SWITCH, AND INSTALLATION.
COORDINATE ELECTRICAL
POWER TO COMPONENTS WITH
DIVISION 16.
DISCHARGE
TO FS-1
U.L. LISTED ELECTRICAL
TIMER. 24 HOUR TYPE WITH
MANUAL BYPASS.
TORK 1100 SERIES
PROVIDE CONNECTION.
TO STORM SEWER
CLEAN OUT PLUG
WITH RAISED NUT.
4" 2"
BUILDING
FINISH.
DOWNSPOUT
BY OTHERS.
PROJECT NUMBER:
SHEET TITLE:
DRAWN BY:
CONSULTANT:
SHEET:
Suite 300 503.221.2077
Portland OR 97209 www.lrsarchitects.com
A R C H I T E C T S 720 NW Davis 503.221.1121
EXPIRES: 12/31/23
/1
/2
:1
:5
P
M C
R e v it P ro je c ts
\M E
P
C la c k a m a s F a ir g ro u n d s M
P v ra y m o n d c
.r v t
CG
P902
DETAILS -
PLUMBING
BID SET
CLACKAMAS
COUNTY
FAIRGROUNDS
MULTI-PURPOSE
BUILDING
694 NE 4TH AVENUE
CANBY, OR 97013
222033
5.05.2023
LRS Architects, Inc. © 2023
PROJECT
CONTACT
www.interfaceengineering.com
Ryan McClain 2022-0151
100 SW Main Street, Suite 1600 Portland, OR 97204
TEL 503.382.2266
NO SCALE
1 GAS REGULATOR VENT PIPING THRU ROOF
NO SCALE
2 GAS WATER HEATER
NO SCALE
3 DOWNSPOUT/STORM DRAIN CONNECTION
| Sheets |
| P000 - SYMBOL LIST AND GENERAL NOTES - PLUMBING |
| P201 - OVERALL UNDERGROUND PLAN |
| P202 - OVERALL PLUMBING FLOOR PLAN |
| P203 - ENLARGED PLAN AND RISER - NORTHEASTERN PLUMBING UNDERGROUND |
| P204 - ENLARGED PLAN AND RISER - NORTHEASTERN PLUMBING |
| P205 - ENLARGED PLAN AND RISER - SOUTHEASTERN PLUMBING UNDERGROUND |
| P206 - ENLARGED PLAN AND RISER - SOUTHESTERN PLUMBING |
| P701 - SCHEDULES - PLUMBING |
| P902 - DETAILS - PLUMBING |
File details come from the government source that posted it. Updated .