Attachment E - Construction Experience Project Data.pdf

PDF 17 KB Posted

Attached to
DESIGN-BID-BUILD, REPAIR AMMUNITION RAIL TRESTLE AND CULVERT, NAVAL WEAPONS STATION EARLE (NWSE), COLTS NECK, NEW JERSEY
Solicitation number
N4008525R2611
Issued by

About this file

Attachment E is a Construction Experience Project Data Sheet template for the Design-Bid-Build (DBB) project to Repair Ammunition Rail Trestle & Culvert at Naval Weapons Station Earle in Colts Neck, New Jersey. The form is designed for contractors to provide detailed information about their previous construction project experience, including project type, contract details, work performed, award and completion dates, and contract characteristics.

The template requires contractors to document specifics such as their role (prime/sub/joint venture), percentage of work performed, contract type (firm-fixed price, cost/time and material), project type (new construction, renovation, repair), and delivery method (design-build, design-bid-build, IDIQ). Sections 8 and 9 allow contractors to provide narrative descriptions of the project's relevance to the current Request for Proposal and a detailed account of work self-performed, enabling the government to assess the contractor's qualifications and experience for the ammunition rail trestle and culvert repair project.

View the file

Other files

File Type Posted
N4008525R2611 Amendment 0009.pdf PDF
N4008525R2611 Amendment 0008.pdf PDF
N4008525R2611 Amendment 0007.pdf PDF
N4008525R2611 Amendment 0006.pdf PDF
N4008525R2611 Amendment 0005.pdf PDF
Price Proposal Form - Rev 3.pdf PDF
N4008525R2611 Amendment 0004.pdf PDF
N4008525R2611 Amendment 0003.pdf PDF
Price Schedule - Revision 2.pdf PDF
NWSE Geotech Report - Part C.pdf PDF
NWSE Geotech Report - Part A.pdf PDF
N4008525R2611 Amendment 0002.pdf PDF
NWSE Geotech Report - Part D.pdf PDF
NWSE Geotech Report - Part B.pdf PDF
ATT 2B 5G3 - Construction Activity Stormwater 04222025.pdf PDF
Amendment 01 P1712269 Repair Ammunition Rail Trestle and Culvert.pdf PDF
N4008525R2611 Site Visit Log.pdf PDF
ATT 2Ci Draft Permit Inventory.pdf PDF
ATT 2Civ Draft SR Transmittal Letter.pdf PDF
Specification 00 01 15 Drawing Index - Amendment 1.pdf PDF
ATT 2Ciii Draft Staff Report.pdf PDF
N4008525R2611 Amendment 0001.pdf PDF
ATT 2Cii Draft Permit Requirements.pdf PDF
Price Proposal Form - Rev 1.pdf PDF
ATT 2C 1096079_DST250001_36334404.pdf PDF
ATT 2A - FSCD Certification Letter 041425.pdf PDF
N4008525R2611.pdf PDF
Attachment A -Pre-Proposal Inquiry Log Rev.xlsx XLSX spreadsheet
Attachment F - Historical Small Business Utilization.pdf PDF
Attachment B - PIEE Vendor Access Instructions.pdf PDF
Attachment H - Price Proposal Form.pdf PDF
Attachment C - Past Performance Questionnaire.pdf PDF
Attachment D - Small Business Subcontracting Plan.pdf PDF
Attachment G - Small Business Participation Commitment.pdf PDF
Attachment I - Specifications.pdf PDF
Attachment J - Drawings.pdf PDF
Show all 36

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DBB, Repair Ammunition Rail Trestle & Culvert N40085-25-R-2611

NWSE, Colts Neck. New Jersey Attachment E

ATTACHMENT E

CONSTRUCTION EXPERIENCE PROJECT DATA SHEET

Project No. (check one) : CON #1 CON #2 CON #3 CON #4 CON #5

1. Experience for: Offeror Joint-Venture Other (Explain)

Firm Name:

Address:

Phone Number:

UEI Number:

Cage Code:

Point of Contact: Contact Phone Number:

2. Work Performed as: Prime Contractor Sub Contractor Joint Venture Other (Explain)

Percent of project work performed:

If subcontractor, who was prime (Name/Phone #):

3. Contract Number: Delivery/Task Order Number:

Title:

Location:

4. Award Date (mm/dd/yy): Completion Date (mm/dd/yy):

5. Type of work:

New Construction Renovation Repair Alteration Other (explain):

6. Type of Contract/Task Order: (Check ALL that apply)

Firm-Fixed Price Cost/Time and Material Other (explain):

7. Construction Project:

Award Amount: Final Price:

Type of Contract/Task Order: (Check ALL that apply)

Design-Build Design-Bid-Build Delivery/Task Order (IDIQ) Other (explain):

If Design-Build, identify the Lead Design Firm:______________________________________________

DBB, Repair Ammunition Rail Trestle & Culvert N40085-25-R-2611

NWSE, Colts Neck. New Jersey Attachment E

8. Provide a detailed description of the project and the relevancy to the project requirements of this RFP (i.e.:

unique features, square footage, construction methods). If design-build, include a description of the design-effort.

9. Provide a detailed description of what work your firm self-performed on this project:

10. Other Information:

File details come from the government source that posted it. Updated .