This document is an asbestos survey report for Building 530 at Luke Air Force Base in Glendale, Arizona, prepared by ProTeX on May 3, 2024. The survey was conducted on April 25, 2024, by a certified building inspector who collected fifteen bulk samples from various building materials including carpet, ceramic tile, drywall, and concrete foundation.
The laboratory analysis by Eurofins EMLab P&K using Polarized Light Microscopy (PLM) found no asbestos-containing materials in any of the samples. The report recommends that if additional suspect building materials are discovered during future renovation or demolition activities, they should be sampled and analyzed for asbestos content prior to disturbance. The survey was limited to building materials scheduled to be impacted by a potential demolition and/or renovation project, and the samples were collected from locations including Room 111, an entry way, and a mechanical room.
View the file
Other files
Show all 31
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PHOENIX
1102 W SOUTHERN AVE., STE 4
TEMPE, ARIZONA 85282
(O) 602-272-PTX1 (7891)
DISPATCH 602-272-7890
(F) 602-272-7892
WWW.PROTEX-AZ.COM
TUCSON
916 WEST GRANT ROAD
TUCSON, ARIZONA 85705
(O) 520-352-1050
DISPATCH 520-352-0150
(F) 520-352-0150
WWW.PROTEX-AZ.COM
Geotechnical Engineering • Construction Materials Testing • Special Inspections • Environmental
May 3, 2024
Carl F. Moser, Jr., Civ, DAF
Environmental Program Manager
56 CES/CEIEA
13970 Gillespie Drive
Luke AFB, AZ 85309 ProTeX Job # 15315
RE: Limited Asbestos Survey
Luke Air Force Base
Building #530
Glendale, Arizona 85309
Dear Mr. Moser:
In accordance with your authorization to proceed, ProTeX has conducted a limited asbestos survey of Building
#530 (the site) located at Luke Air Force Base in Glendale, Arizona. This letter report includes summaries of our activities, findings, and recommendations.
PROJECT BACKGROUND
ProTeX was retained by Luke Air Force Base (AFB) Environmental Management to conduct an asbestos survey of Building #530 at the above referenced address. The survey was limited to building materials scheduled to be impacted by a potential demolition and/or renovation project.
ACTIVITIES
On April 25, 2024, Ms. Sarah Berger, an Environmental Protection Agency (EPA) and Asbestos Hazard Emergency
Response Act (AHERA) Certified Building Inspector with ProTeX, collected fifteen (15) bulk samples of suspect building materials from the site.
The samples were submitted via chain of custody protocol to Eurofins EMLab P&K, LLC of Phoenix, Arizona for asbestos analysis via PLM. Eurofins EMLab P&K is approved by the Arizona Department of Health Services pursuant to Arizona Revised Statute (A.R.S.) § 36-495.02 (5) to perform airborne and bulk asbestos fiber analysis
(ADHS No. AZ0964). In addition, Eurofins EMLab P&K is accredited by the National Voluntary Laboratory Ac-creditation Program (NVLAP No. 500031-0) for bulk asbestos fiber analysis. Sample analysis was conducted via
Polarized Light Microscopy (PLM) in general accordance with EPA Method 600/R-93/116 and/or EPA 600/M4-82-
020. The analytical laboratory reports are attached to this letter report.
http://www.protex-az.com/ http://www.protex-az.com/
Asbestos Survey
Luke Air Force Base
FINDINGS
According to federal regulations, any material containing greater than one percent (1%) asbestos as determined by
PLM is considered asbestos-containing material (ACM). Materials considered asbestos-containing are highlighted in bold. A summary of the samples collected by ProTeX inspectors is presented in the following table:
Sample
No.
Sample
Description Location
Approximate
Quantity
(SF)
Friable
Y/N
Asbestos
Content
1A
Carpet
Room 111 Throughout
120 SF
N ND
1B Room 111 Throughout N ND
1C Room 111 Throughout N ND
2A
8’’ x 8’’ Ceramic Tile with Grout
Entry Way Into
25 SF
N ND
2B Room 111 N ND
2C Room 111 N ND
3A
Orange Peel Texture
Drywall System with
Cove Base
Room 111 Wall/Ceiling
500 SF
Y ND
3B Room 111 Wall/Ceiling Y ND
3C Room 111 Wall/Ceiling Y ND
4A
Unfinished Drywall
System
Mechanical Room Walls
200 SF
Y ND
4B Mechanical Room Walls Y ND
4C Mechanical Room Walls Y ND
5A
Concrete Foundation
Slab
Slab
500 SF
N ND
5B Slab N ND
5C Slab N ND
SF = Square Feet
ND = Non-Detect or Below Laboratory Detection Limits
Luke Air Force Base
CONCLUSIONS AND RECOMMENDATIONS
Based on the laboratory results, NONE of the materials sampled are considered asbestos-containing materials.
If additional suspect building materials are discovered during renovation/demolition activities, the materials should be sampled and analyzed for asbestos content prior to disturbance or should be assumed ACM and handled as such.
LIMITATIONS
ProTeX's conclusions and recommendations, as presented in this report, are based on limited sampling and analysis. The samples collected and used for testing, and the observations made, are believed to be representative of the area(s) evaluated.
The environmental services described in this report have been conducted in general accordance with current regu-latory guidelines and the standard-of-care exercised by environmental consultants performing similar work in the project area. No other warranty, expressed or implied, is made regarding the professional conclusions presented in this report. Variations in site conditions may exist and conditions not observed or described in this report may be encountered during subsequent activities.
ProTeX the PT Xperts appreciates the opportunity to provide environmental consulting services to Luke Air Force
Base and looks forward to future projects. Please contact us at (602) 272-PTX1 (7891) if you have any questions pertaining to this report.
Respectfully Submitted, ProTeX, the PT Xperts, LLC
Emily R Rogers, RG
Environmental Professional
B.S. Geology
Sarah Berger
Environmental Scientist
B.S. Earth Science
Figure 1 & 2 –Sample Location Map
Appendix A – Personnel Certifications
Appendix B – Laboratory Reports and Chain-of-Custody
Distribution: (1) Addressee (PDF)
Luke Air Force Base
FIGURE 1 & 2
SAMPLE LOCATION MAP
ProTeX Job No. 15315
Scale: NTS Drawn By: SB
Luke Air Force Base
Building 530
Glendale, AZ 85355
Date: 5/1/2023
Fig. 1 (Sample Location Map – Room 115 Interior) Limited Asbestos Survey
1A
5A
1C
1B
2A
2B 2C
3A
3B
3C
ProTeX Job No. 15315
Scale: NTS Drawn By: SB
Luke Air Force Base
Building 530
Glendale, AZ 85355
Date: 5/1/2023
Fig. 2 (Sample Location Map – Exterior Maintenance Room) Limited Asbestos Survey
5B
5C
4B
4A
4C
Luke Air Force Base
APPENDIX A
PERSONNEL CERTIFICATIONS
Sarah Berger
June 15, 2023
ON-4644-9895-061523
15-Jun-2023
15-Jun-2024
Powered by TCPDF (www.tcpdf.org) http://www.tcpdf.org
Luke Air Force Base
APPENDIX B
LABORATORY REPORTS AND CHAIN-OF-CUSTODY
Approved by:
Approved Signatory Roshanak Kalantari
Report for:
Christine McNally, CSM ProTex 1102 W. Southern Ave.
Suite #4 Tempe, AZ 85282
Regarding:
Eurofins EPK Built Environment Testing, LLC Project: Luke Air Force Base; Building 530
EML ID: 3622263
All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.
Eurofins EPK Built Environment Testing, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.
Dates of Analysis:
Asbestos PLM: 04-30-2024
Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA METHOD 600/R-93-116, SOP EM-AS-S-1267) NVLAP Lab Code 200945-0
EMLab ID: 3622263, Page 1 of 5Eurofins EPK Built Environment Testing, LLC
Eurofins EPK Built Environment Testing, LLC 1010 N Central Avenue, Suite 460, Glendale, CA 91202
(800) 651-4802 www.eurofinsus.com/Built Client: ProTex C/O: Christine McNally, CSM Re: Luke Air Force Base; Building 530
Date of Sampling: 04-25-2024 Date of Receipt: 04-25-2024 Date of Report: 04-30-2024
ASBESTOS PLM REPORT
Total Samples Submitted: 15 Total Samples Analyzed: 15
Total Samples with Layer Asbestos Content > 1%: 0
Location: 1A, Carpet Lab ID-Version‡: 17726895-1
Sample Layers Asbestos Content Multicolored Carpet ND
Yellow Mastic ND Black Foam ND
Composite Non-Asbestos Content: 40% Synthetic Fibers Sample Composite Homogeneity: Moderate
Location: 1B, Carpet Lab ID-Version‡: 17726896-1
Sample Layers Asbestos Content Multicolored Carpet ND
Yellow Mastic ND Black Foam ND
Composite Non-Asbestos Content: 40% Synthetic Fibers Sample Composite Homogeneity: Moderate
Location: 1C, Carpet Lab ID-Version‡: 17726897-1
Sample Layers Asbestos Content Multicolored Carpet ND
Yellow Mastic ND Black Foam ND
Composite Non-Asbestos Content: 40% Synthetic Fibers Sample Composite Homogeneity: Moderate
Location: 2A, 8"x8" Ceramic Tile w/Grout Lab ID-Version‡: 17726898-1
Sample Layers Asbestos Content Brown Ceramic Tile ND
Gray Grout ND Sample Composite Homogeneity: Moderate
EMLab ID: 3622263, Page 2 of 5Eurofins EPK Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".
(800) 651-4802 www.eurofinsus.com/Built Client: ProTex C/O: Christine McNally, CSM Re: Luke Air Force Base; Building 530
Date of Sampling: 04-25-2024 Date of Receipt: 04-25-2024 Date of Report: 04-30-2024
ASBESTOS PLM REPORT
Location: 2B, 8"x8" Ceramic Tile w/Grout Lab ID-Version‡: 17726899-1
Sample Layers Asbestos Content Brown Ceramic Tile ND
Gray Grout ND Sample Composite Homogeneity: Moderate
Location: 2C, 8"x8" Ceramic Tile w/Grout Lab ID-Version‡: 17726900-1
Sample Layers Asbestos Content Brown Ceramic Tile ND
Gray Grout ND Sample Composite Homogeneity: Moderate
Location: 3A, Orange Peel Texture Drywall System w/Cove Base Lab ID-Version‡: 17726901-1
Sample Layers Asbestos Content Gray Cove Base ND White Texture ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
Location: 3B, Orange Peel Texture Drywall System w/Cove Base Lab ID-Version‡: 17726902-1
Sample Layers Asbestos Content Gray Cove Base ND White Texture ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
EMLab ID: 3622263, Page 3 of 5Eurofins EPK Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/Built Client: ProTex C/O: Christine McNally, CSM Re: Luke Air Force Base; Building 530
Date of Sampling: 04-25-2024 Date of Receipt: 04-25-2024 Date of Report: 04-30-2024
ASBESTOS PLM REPORT
Location: 3C, Orange Peel Texture Drywall System w/Cove Base Lab ID-Version‡: 17726903-1
Sample Layers Asbestos Content Gray Cove Base ND White Texture ND
White Drywall with Brown Paper ND Composite Non-Asbestos Content: 10% Cellulose Sample Composite Homogeneity: Moderate
Location: 4A, Unfinished Drywall System Lab ID-Version‡: 17726904-1
Sample Layers Asbestos Content Cream Tape ND
White Joint Compound ND White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Moderate
Location: 4B, Unfinished Drywall System Lab ID-Version‡: 17726905-1
Sample Layers Asbestos Content Cream Tape ND
White Joint Compound ND White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Moderate
Location: 4C, Unfinished Drywall System Lab ID-Version‡: 17726906-1
Sample Layers Asbestos Content Cream Tape ND
White Joint Compound ND White Drywall with Brown Paper ND
Composite Non-Asbestos Content: 15% Cellulose Sample Composite Homogeneity: Moderate
EMLab ID: 3622263, Page 4 of 5Eurofins EPK Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
(800) 651-4802 www.eurofinsus.com/Built Client: ProTex C/O: Christine McNally, CSM Re: Luke Air Force Base; Building 530
Date of Sampling: 04-25-2024 Date of Receipt: 04-25-2024 Date of Report: 04-30-2024
ASBESTOS PLM REPORT
Location: 5A, Concrete Foundation Slab Lab ID-Version‡: 17726907-1
Sample Layers Asbestos Content Gray Concrete ND
Sample Composite Homogeneity: Good
Location: 5B, Concrete Foundation Slab Lab ID-Version‡: 17726908-1
Sample Layers Asbestos Content Gray Concrete ND
Sample Composite Homogeneity: Good
Location: 5C, Concrete Foundation Slab Lab ID-Version‡: 17726909-1
Sample Layers Asbestos Content Gray Concrete ND
Sample Composite Homogeneity: Good
EMLab ID: 3622263, Page 5 of 5Eurofins EPK Built Environment Testing, LLC
The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.
Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.
‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is
File details come from the government source that posted it. Updated .