Attachment 6 - Drawings Part 1 of 3 - Manchester - 608-315.pdf

PDF 22 MB Posted

Attached to
Y1DB--Construct Specialty Care Building - Manchester Minor Project 608-315
Solicitation number
36C77625B0024
Issued by

About this file

This document is a comprehensive set of architectural and structural engineering drawings for the construction of a new Specialty Care Building at the VA Medical Center in Manchester, New Hampshire. The drawings, dated December 20, 2023, provide detailed plans for a single-story, fully sprinklered facility with multiple roof levels, including a main roof, high roof, and penthouse roof. The project involves constructing a new building addition adjacent to an existing medical facility, with specific focus on structural details, foundation work, steel framing, concrete specifications, and architectural elements. Key technical components include composite steel deck, concrete slabs, wall reinforcement, steel connections, and specialized design features to integrate with the existing VA Medical Center infrastructure.

The drawings cover multiple disciplines including civil, structural, architectural, mechanical, electrical, plumbing, fire protection, and telecommunications systems. Specific design considerations include seismic load parameters, wind load specifications, foundation requirements, and compliance with building codes such as the International Building Code and VA design guidelines. The project emphasizes detailed engineering specifications, with extensive notes on construction methods, material requirements, welding standards, and structural connection details. The overall design appears to prioritize functionality, structural integrity, and seamless integration with the existing medical facility campus.

View the file

Other files

File Type Posted
36C77625B0024 0008.docx DOCX document
Attachment 5 - 084413 - Glazed Aluminum Curtain Wall.pdf PDF
Attachment 4 - VAMC_MANCHESTER_A5-2.1 - 608-315.pdf PDF
Attachment 1 - Virtual Bid Opening Updated - Manchester.pdf PDF
Attachment 2 - Tech Qs - Manchester 618-315 2025-08-22 responses.docx DOCX document
36C77625B0024 0008.docx DOCX document
Attachment 3 - VAMC_MANCHESTER_A2-2.3 - 608-315.pdf PDF
S06 - Atch 1 - Virtual Bid Opening Updated 8.19.25 - Manchester.pdf PDF
36C77625B0024 0007.docx DOCX document
S06 - Atch 1 - Tech Qs - Manchester 618-315 NEW 8.13.2025.docx DOCX document
S06 - Atch 2 - Panel DP nameplate - 608-315.jpg JPG image
36C77625B0024 0006.docx DOCX document
Atch 1 - Virtual Bid Opening UPDATED - Manchester NH 608-315.pdf PDF
36C77625B0024 0005.docx DOCX document
S06 - Atch 4 - Bid Addendum Bldg 1 Basement Floor Plan.pdf PDF
S06 - Atch 1 - Tech Qs - Manchester 618-315 8.7.2025.docx DOCX document
36C77625B0024 0004.docx DOCX document
S06 - Atch 2 - Q60 Response Select Drawings from Existing Building Construction.pdf PDF
S06 - Atch 6 - 122400 - Window Shades.pdf PDF
S06 - Atch 5 - Bid Addendum Bldg 1 First Floor Plan.pdf PDF
S06 - Atch 3 - Bid Addendum 1 Drawing Corrections.pdf PDF
36C77625B0024 0003.docx DOCX document
Atch 2 - 087100 Door Hardware 2025-07-31.pdf PDF
Atch 1 - Tech Qs - Manchester 608-315 07252025.docx DOCX document
Atch 6 - Bid Addendum Bldg 1 First Floor Plan.pdf PDF
Atch 2 - Site Visit Agenda - Manchester NH 608-315.pdf PDF
Atch 8 - 122400 - Window Shades.pdf PDF
Atch 3 - Site Visit Sign-In Sheet - Manchester NH 608-315.pdf PDF
Atch 4 - Virtual Bid Opening Information - Manchester NH 608-315.pdf PDF
36C77625B0024 0002.docx DOCX document
Atch 5 - Bid Addendum Bldg 1 Basement Floor Plan.pdf PDF
Atch 1 - Tech Qs - Manchester 608-315 FINAL.docx DOCX document
Atch 7 - Bid Addendum Drawing Corrections.pdf PDF
Atch 1 - Specs V2 of 2 - Manchester - 608-315 Rev 2025-06-24.pdf PDF
36C77625B0024 0001.docx DOCX document
Attachment 9 - Brand Name JA - Manchester Redacted - 608-315.pdf PDF
Attachment 3 - Site Visit Instructions - Manchester - 608-315.pdf PDF
Attachment 1 - Limitations on Subcontracting - Construction - 608-315.docx DOCX document
Attachment 5 - Specifications V2 of 2 - Manchester - 608-315.pdf PDF
36C77625B0024_1.docx DOCX document
Attachment 8 - Drawings Part 3 of 3 - Manchester - 608-315.pdf PDF
Attachment 4 - Specifications V1 of 2 - Manchester - 608-315.pdf PDF
Attachment 2 - DBA Wage Rates - Manchester - 608-315 - NH20250021 03.14.2025.pdf PDF
Attachment 7 - Drawings Part 2 of 3 - Manchester - 608-315.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPCONSULTANT

321 4 5 6 7 8 9 10

129 South St, 2nd floor Boston, MA 02210

T: 617.772.0260 F: 617.772.0261 www.e4harchitecture.com

FINAL FOR

CONSTRUCTION

FULLY SPRINKLERED

STRUCTURAL MEP / FP

Simpson Gumpertz & Heger 480 Totten Pond Road Waltham, MA 02451

T: 781.907.9000 sgh.com

BR+A

10 Guest Street, 4th FLR Boston, MA 02135

T: 617.254.0016 brplusa.com

CIVIL

Meridian Associates, Inc.

500 Cummings Center, Suite 5950 Beverly, MA 01915

T: 978.299.0447 meridianassoc.com

B

IM

/V

A M

C M a n c h e s te r S p e c ia lt y C lin ic

/V A

M C

M

A N

C H

E S

T E

R S

P E

C C

L

IN

IC

R

.r v t

/1 /2

:0

:1

A M

AG-1.1

COVER SHEET

718 Smyth Rd, Manchester, NH 03104

608-315

12/20/2023

DEPARTMENT OF VETERANS AFFAIRS

VA MEDICAL CENTER MANCHESTER, NH

718 Smyth Road Manchester, NH 03104

ISSUED FOR: FINAL CONSTRUCTION DECEMBER 20, 2023

Revisions: Date:

CONSTRUCT SPECIALTY CARE BUILDING

CONSTUCT SPECIALTY

CARE BUILDING

CONSTRUCT SPECIALTY

CARE BUILDING

A/C

AB

ACC

ACT

AD

ADHES

ADJ

AFF

AGGR

AHU

ALT

ALUM

ANOD

ARCH

ASB

ASPH

AUTO

BD

BITUM

BLDG

BLK

BLKG

BM

BOT

BR

BRG

BRK

BRZ

BSMT

BTU

BUR

BV

CAB

CB

CCT

CCU

CEM

CFCI

CFOI

CG

CI

CIR

CJ

CL

CLG

CLKG

CLO

CLOS

CLR

CMU

CO

COL

CONC

CONF

CONN

CONT

CONTR

CORR

CPT

CR

CS

CSI

CSMT

CT

CW

D/A

DBL

DEG

DEMO

DEMOUNT

DEP

DET

DF

DH

DIA

DIAG

DIM

DIV

DN

DR

DW

DWG

DWR

E

EA

ED

EF

EIFS

EJ

EL

ELEC

ELEV

EMERG

ENCL

EO

EPS

EXPS

EQ

EQUIP

ETR

EWC

EXCAV

EXH

EXIST

EXP

EXT

FA

FAB

FD

FE

FEC

FF EL

FHEC

FHC

FIN

FLR

FLUOR

FM

FOC

FOF

FOS

FPRF

FRPL

FRT

FT (')

FTG

FURN

FURR

FUT

GA

GALV

GC

GL

GRD

GYP

GWB

HB

H/C

HCWD

HD

HDNR

HDR

HDWD

HDWR

HM

HORIZ

HP

HR

HT

HTG

HVAC

HW

ICU

ID

IN (")

INCL

INFO

INSUL

INT

INV

AIR CONDITIONING

ANCHOR BOLT

ACCESS

ACOUSTICAL CEILING TILE

AREA DRAIN

ADHESIVE

ADJUSTABLE

ABOVE FINISHED FLOOR

AGGREGATE

AIR HANDLING UNIT

ALTERNATE

ALUMINUM

ANODIZED

ARCHITECTURAL

ASBESTOS

ASPHALT

AUTOMATIC

BOARD

BITUMINOUS

BUILDING

BLOCK

BLOCKING

BENCH MARK

BOTTOM

BUMPER RAIL

BEARING

BRICK

BRONZE

BASEMENT

BRITISH THERMAL UNIT

BUILT-UP ROOFING

BEVELED

CABINET

CATCH BASIN

CUBICAL CURTAIN TRACK

CORONARY CARE UNIT

CEMENT

CONTRATOR FURNISHED

CONTRACTOR INSTALLED

CONTRACTOR FURNISHED

OWNER INSTALLED

CORNER GUARD

CAST IRON

CIRCLE

CONSTRUCTION JOINT

CENTER LINE

CEILING

CAULKING

CLOSET

CLOSURE

CLEAR

CONCRETE MASONRY UNIT

CLEAN OUT

COLUMN

CONCRETE

CONFERENCE

CONNECT (ION)

CONTINUOUS

CONTRACTOR

CORRIDOR

CARPET

CHAIR RAIL

CENTRAL STERILE

CONSTRUCTION SPECIFICATION

INSTITUTE

CASEMENT

CERAMIC TILE

COLD WATER

DOUBLE ACTING

DOUBLE

DEGREE

DEMOLITION

DEMOUNTABLE

DEPRESSED

DETAIL

DRINKING FOUNTAIN

DOUBLE HUNG

DIAMETER

DIAGONAL

DIMENSION

DIVISION

DOWN

DOOR

DISHWASHER

DRAWING

DRAWER

EAST

EACH

EMERGENCY DEPARTMENT

EXHAUST FAN

EXTERIOR INSULATING

FINISH SYSTEM

EXPANSION JOINT

ELEVATION

ELECTRIC (AL)

ELEVATOR

EMERGENCY

ENCLOSURE

EMERGENCY ELECTRICAL OUTLET

EPOXY PAINT SYSTEM

EXTERIOR PAINT SYSTEM

EQUAL

EQUIPMENT

EXISTING TO REMAIN

ELECTRIC WATER COOLER

EXCAVATE

EXHAUST

EXISTING

EXPANSION

EXTERIOR

FIRE ALARM

FABRICATED

FLOOR DRAIN

FIRE EXTINGUISHER

FIRE EXTINGUISHER CABINET

FINISH FLOOR ELEVATION

FIRE HOSE &

EXTINGUISHER CABINET

FIRE HOSE CABINET

FINISH (ED)

FLOOR

FLUORESCENT

FACTORY MUTUAL

FACE OF CONCRETE

FACE OF FINISH

FACE OF STUD

FIREPROOF

FIREPLACE

FIRE RETARTANT TREATED

FOOT / FEET

FOOTING

FURNISH, FURNITURE

FURRED, FURRING

FUTURE

GAUGE

GALVANIZED

GENERAL CONTRACTOR

GLASS, GLAZING

GRADE

GYPSUM BOARD, GYPSUM

GYPSUM WALLBOARD

HOSE BIBB

HANDICAPPED

HOLLOW CORE WOOD

HEAVY DUTY

HARDENER

HEADER

HARDWOOD

HARDWARE

HOLLOW METAL

HORIZONTAL

HIGH POINT

HAND RAIL

HEIGHT

HEATING

HEATING, VENTILATING

AND AIR CONDITIONING

HOT WATER

INTENSIVE CARE UNIT

INSIDE DIAMETER

INCHES

INCLUDING

INFORMATION

INSULATE, INSULATION

INTERIOR

INVERT

IPS

IVT

JAN

JST

JT

KIT

KO

KPL

KR

L

LAB

LAM

LAV

LBL

LF

LH

LHR

LL

LP

MATL

MAX

MBR

MECH

MEMB

MFR

MH

MIN

MISC

MO

MOD

MON

MR

MTD

MTL

MULL

N N/A

NIC

NO, #

NOM

NRC

NTS

OA

OBS

OC

OD

OFCI

OFF

OFOI

OH

OPQ

OPNG

OPP

PACU

PAR

PARTN

PBD

PC

PERF

PERIM

P

PLAM

PLAS

PLYWD

PNL

POLY

PP

PR

PREFAB

PRT

PSF

PSI

PT

PTSTA

PVC

PWC

QT

QTY

R

RA

RAD

RB

RD

REF

REINF

REQD

RESIL

REV

RH

RHR

RM

RO

ROW

RWC

S

SCHED

SCWD

SECT

SEG

SF

SHR

SHT

SHTG

SIM

SPEC

SPKR

SQ

SS

SSS

SST

STA

STD

STC

STL

STOR

STRUCT

SURG

SUSP

SV

SRV

SYM

T T&B T&G

TEL

TELEM

TEMP

TERR

THK

THRES

TLT

TOC

TOF

TOS

TOW

TRANSF

TV

TYP

UL

UNEXCAV

UNFIN

UON

UR

VAR

VAT

VB

VCB

VCT

VERT

VEST

VIF

VWC

W W/ W/O

WC

WD

WDW

WF

WI

WT

WWF

WWM

YD

INTERIOR PAINT SYSTEM

INTRAVENOUS (IV) TRACK

JANITOR

JOIST

JOINT

KITCHEN

KNOCKOUT

KICK PLATE

KICK RAIL

LENGTH

LABORATORY

LAMINATE (D)

LAVATORY

LABEL

LINEAR FOOT (FEET)

LEFT HAND

LEFT HAND REVERSE

LIVE LOAD

LOW POINT

MATERIAL

MAXIMUM

MEMBER

MECHANICAL

MEMBRANE

MANUFACTURER

MAN HOLE

MINIMUM

MISCELLANEOUS

MASONRY OPENING

MODULAR

MONITOR

MOISTURE RESISTANT

MOUNTED

METAL

MULLION

NORTH

NOT APPLICABLE

NOT IN CONTRACT

NUMBER

NOMINAL

NOISE REDUCTION COEFFICIENT

NOT TO SCALE

OVERALL

OBSCURE

ON CENTER

OUTSIDE DIAMETER

OWNER FURNISHED

CONTRACTOR INSTALLED

OFFICE

OWNER FURNISHED

OWNER INSTALLED

OVERHEAD

OPAQUE

OPENING

OPPOSITE

POST ANESTHESIA CARE UNIT

PARALLEL

PARTITION

PARTICLE BOARD

PERSONAL COMPUTER

PERFORATED

PERIMETER

PLATE

PLASTIC LAMINATE

PLASTER

PLYWOOD

PANEL

POLYETHYLENE

PUSH PAD

PAIR

PREFABRICATED

PRESSURE TREATED

POUNDS PER SQUARE FOOT

POUNDS PER SQUARE INCH

PAINT

PNEUMATIC TUBE STATION

POLYVINYL CHLORIDE

PROTECTIVE WALL COVERING

QUARRY TILE

QUANTITY

RISER

RETURN AIR

RADIUS

RESILIENT BASE

ROOF DRAIN

REFRIGERATOR

REINFORCED

REQUIRED

RUBBER

REVISION

RIGHT HAND

RIGHT HAND REVERSE

ROOM

ROUGH OPENING

RIGHT OF WAY

RAINWATER CONDUCTOR

SOUTH

SCHEDULE

SOLID CORE WOOD

SECTION

SEGMENT

SQUARE FOOT

SHOWER

SHEET

SHEATHING

SIMILAR

SPECIFICATION

SPEAKER

SQUARE

SERVICE SINK

SURGICAL SCRUB SINK

STAINLESS STEEL

STATION

STANDARD

SOUND TRANSMISSION CLASS

STEEL

STORAGE

STRUCTURAL, STRUCTURE

SURGERY

SUSPENDED

SHEET VINYL

SLIP RESISTANT VINYL

SYMETRICAL

TREAD (S)

TOP AND BOTTOM

TONGUE AND GROOVE

TELEPHONE

TELEMETRY

TEMPORARY

TERRAZZO

THICK (NESS)

THRESHOLD

TOILET

TOP OF CONCRETE

TOP OF FOOTING

TOP OF STEEL

TOP OF WALL

TRANSFORMER

TELEVISION

TYPICAL

UDERWRITERS LABORATORY

UNEXCAVATED

UNFINISHED

UNLESS OTHERWISE NOTED

URINAL

VARNISH

VINYL ASBESTOS TILE

VINYL BASE

VINYL COVE BASE

VINYL COMPOSITION TILE

VERTICAL

VESTIBULE

VERIFY IN FIELD

VINYL WALL COVERING

WEST

WITH

WITHOUT

WATER CLOSET

WOOD

WINDOW

WIDE FLANGE

WROUGHT IRON

WEIGHT

WELDED WIRE FABRIC

WELDED WIRE MESH

YARD

ARCHITECTURAL ABBREVIATIONSARCHITECTURAL SYMBOLS MATERIAL LEGEND

HARDWOOD TRIM

WOOD BLOCKING OR

STUCCO/ MORTAR

GYPSUM BOARD

ALUMINUM

RIGID INSULATION

BATT INSULATION

STEEL

ROOF BALLAST

CRUSHED GRAVEL

TOPSOIL

CONCRETE

BRICK

CERAMIC TILE

WOOD SHIM

CONCRETE BLOCK

PLYWOOD

SHEET METAL

WATERPROOF

GLASS (LARGE SCALE)

ACOUSTICAL TILE

MARBLE

PLASTER/MORTAR,

PRECAST CONC, CONC

CONTINUOUS NAILER

(IN ELEVATION)

MEMBRANE

OR EIFS IN ELEVATION

PLYWOOD

CENTERLINE

PROPERTY/REFERENCE

LINE

FLOOR LINE ELEVATION

HIDDEN OR FUTURE WORK

OR WORK TO BE REMOVED

SECTION/BREAK LINE

MATCH LINE

INDICATES WORK SIDE

MATCH LINE - SEE A1-#

SPOT ELEVATION NEW

WORK

100.00

BENCH MARK ELEVATION

BM

96.5

CHANGE IN FLOOR OR CEILING

ELEVATION (PLAN VIEW)

NEW PARTITION

NEW SWING DOOR (180 Deg.)

NEW SWING DOOR (90 Deg.)

EXISTING COLUMN LINE

REFERENCE

NEW COLUMN LINE

REFERENCE

ELEVATION TAG ON

SECTION

+/- 0"

A3-1

A2-1

EXTERIOR

ELEVATION TAG

BUILDING OR WALL

SECTION TAG

A3-1

PLAN OR ENLARGED

DETAIL TAG

A4-1 INTERIOR

ELEVATION TAG

OFFICE

ROOM NAME & NUMBER TAG

PARTITION TYPE TAG1A

101A DOOR NUMBER TAG

WINDOW TAGA

STOREFRONT TAG

FURNITURE OR EQUIPMENT

FURNISHED BY OWNER

AUTOMATIC DOOR PUSH PLATE

FIRE EXTINQUISHER RECESSED

MANEUVERING CLEARANCES - DOORS

MOUNTING HEIGHTS

MOUNTING HEIGHTS

FEC

NEW SWING DOOR (162 Deg.)

A

1' - 6"

* 1' - 0"

* WITH BOTH CLOSER AND A

LATCH

PUSH SIDE

PULL SIDE

FRONT APPROACH

a

PUSH SIDE

PULL SIDE

HINGE SIDE APPROACH

3' - 0" a b

3' - 6" b

1' - 10"

* WITH BOTH CLOSER AND A

LATCH

PUSH SIDE

PULL SIDE

LATCH SIDE APPROACH

2' - 0"

2' - 0"

* WITH CLOSER

NOTES:

1. INFORMATION TAKEN FROM 2010 ADA STANDARDS FOR ACCESSIBLE DESIGN, CHAPTER 4, SECTION 404.

2. ALL DIMENSIONS PROVIDED ARE MINUMUM DIMENSIONS.

0' - 4"

0' - 4"

DUPLEX AND/OR

DATA, VOICE

JACK

DUPLEX AND/OR

DATA, VOICE JACK

ABOVE WORK SURFACE

FINISHED FLOOR

WALL SWITCH/

OCCUPANCY

SENSOR

NOTES:

DIMENSIONS SHOWN HERE ARE TYPICAL,

UNLESS NOTED OTHERWISE WITHIN

DOCUMENTS

FIRE ALARM AUDIO/VISUAL ALARM

* WHICHEVER DIMENSION PUTS

THE DEVICE LOWER

CEILING

ACCESSIBLE CONTROLS

(I.E. THERMOSTAT, LIGHT,

FIRE ALARM PULLSTATION)

T O

A C

T

IV

A T

IN

G

H A

N D

L E

/L E

V E

R

DOOR

FRAME

PAPER TOWEL

DISPENSER

NOTES:

DIMENSIONS SHOWN HERE ARE TYPICAL,

UNLESS NOTED OTHERWISE WITHIN

DOCUMENTS

SOAP

DISPENSER

VISUAL ACUITY

5'

0"

5'

4"

BINOCULAR INDIRECT

OPTHALMOSCOPE

4'

6"

SHARPS CONTAINER

5'

0"

COAT HOOK

4'

0"

OTOSCOPE AND

OPHTHALMOSCOPE

M A

X

MIRROR

M A

X

4'

HAND

SANITIZER

3'

3'

TYP. CORRIDOR DOOR WITH CARD

READER AND SIGNAGE

TYP. CORRIDOR DOOR WITH HAND

SANITZER AND SIGNAGE

4'

WALL PHONE JACK

AED

4'

T Y

P

2'

0"

WALL MOUNTED SINK

3'

3'

4"

9"

A

LI

G N

4'

SIGNAGE

CARD READER

4"

3'

4"

4"

9"

1' - 7"

4'

4'

SIGNAGE

HAND

SANITZER

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPCONSULTANT

321 4 5 6 7 8 9 10

129 South St, 2nd floor Boston, MA 02210

T: 617.772.0260 F: 617.772.0261 www.e4harchitecture.com

FINAL FOR

CONSTRUCTION

FULLY SPRINKLERED

STRUCTURAL MEP / FP

Simpson Gumpertz & Heger 480 Totten Pond Road Waltham, MA 02451

T: 781.907.9000 sgh.com

BR+A

10 Guest Street, 4th FLR Boston, MA 02135

T: 617.254.0016 brplusa.com

CIVIL

Meridian Associates, Inc.

500 Cummings Center, Suite 5950 Beverly, MA 01915

T: 978.299.0447 meridianassoc.com

B

IM

/V

A M

C M a n c h e s te r S p e c ia lt y C lin ic

/V A

M C

M

A N

C H

E S

T E

R S

P E

C C

L

IN

IC

R

.r v t

/1 /2

:0

:1

A M

AG-1.2

INDEX SHEET

718 Smyth Rd, Manchester, NH 03104

608-315

12/20/2023

DRAWING LIST

Sheet Number Sheet Name

Sheet Issue Date

GENERAL

AG-1.1 COVER SHEET 12/20/2023

AG-1.2 INDEX SHEET 12/20/2023

AG-1.3 FIRST FLOOR LIFE SAFETY PLAN 12/20/2023

CIVIL

C-1.0 EXISTING CONDITIONS & SITE DEMOLITION PLAN 12/20/2023

C-2.0 SITE LAYOUT & MATERIALS PLAN 12/20/2023

C-3.0 GRADING PLAN 12/20/2023

C-4.0 SITE UTILITIES PLAN 12/20/2023

C-5.0 STEAM & CONDENSATE PLAN & PROFILE 12/20/2023

C-6.0 LANDSCAPE PLAN 12/20/2023

C-7.1 DETAILS 12/20/2023

C-7.2 DETAILS 12/20/2023

STRUCTURAL

S0-0.0 STRUCTURAL COVER 12/20/2023

S0-1.0 GENERAL NOTES 12/20/2023

S0-1.1 SYMBOLS AND ABBREVIATIONS 12/20/2023

S1-1.1 FOUNDATION AND FIRST FLOOR PLAN 12/20/2023

S1-1.2 ROOF PLAN 12/20/2023

S2-2.0 EXTERIOR ELEVATIONS 12/20/2023

S3-1.0 COLUMN SCHEDULE 12/20/2023

S4-1.0 TYPICAL CONCRETE DETAILS 12/20/2023

S4-1.1 TYPICAL CONCRETE DETAILS 12/20/2023

S4-1.2 TYPICAL CONCRETE DETAILS 12/20/2023

S4-2.0 CONCRETE DETAILS 12/20/2023

S4-2.1 CONCRETE DETAILS 12/20/2023

S5-1.0 TYPICAL STEEL DETAILS 12/20/2023

S5-1.1 TYPICAL STEEL DETAILS 12/20/2023

S5-1.2 TYPICAL STEEL DETAILS 12/20/2023

S5-1.3 TYPICAL STEEL DETAILS 12/20/2023

S5-2.0 STEEL DETAILS 12/20/2023

S5-2.1 STEEL DETAILS 12/20/2023

ARCHITECTURE

AD1-1.1 DEMOLITION FLOOR PLAN 12/20/2023

A1-1.1 FIRST FLOOR PLAN OVERALL 12/20/2023

A1-1.R ROOF PLAN 12/20/2023

A1-2.1A PARTIAL FLOOR PLAN - A 12/20/2023

A1-2.1B PARTIAL FLOOR PLAN- B 12/20/2023

A1-2.1C PARTIAL FLOOR PLAN - C 12/20/2023

A1-2.3 EQUIPMENT PLAN - A 12/20/2023

A1-2.4 EQUIPMENT PLAN - B 12/20/2023

A1-2.5 EQUIPMENT SCHEDULE 12/20/2023

A1-3.1 REFLECTED CEILING PLAN 12/20/2023

A1-3.2 ROOF DECK - REFLECTED CEILING PLAN 12/20/2023

A1-3.3 CEILING DETAILS 12/20/2023

A1-4.1 SIGNAGE 12/20/2023

A2-2.1 EXTERIOR ELEVATIONS 12/20/2023

A2-2.2 EXTERIOR ELEVATIONS 12/20/2023

A2-2.3 STOREFRONT SCHEDULE AND DETAILS 12/20/2023

A3-1.1 WALL SECTIONS 12/20/2023

A3-2.1 EXTERIOR DETAILS 12/20/2023

A3-2.2 EXTERIOR PLAN DETAILS 12/20/2023

A4-1.1 ENLARGED PLAN TYP. TOILET ROOMS 12/20/2023

A4-1.2 ENLARGED PLAN RECEPTION 12/20/2023

A4-1.3 ENLARGED TYPICAL EXAM ROOM 12/20/2023

A4-1.4 ENLARGED PLAN LOW VISION 12/20/2023

A4-1.5 ENLARGED TYP. PROGRAMMING AND FITTING ROOM 12/20/2023

A4-1.6 INTERIOR ELEVATIONS 12/20/2023

A4-1.7 INTERIOR ELEVATIONS 12/20/2023

A4-1.8 INTERIOR ELEVATIONS 12/20/2023

A4-1.9 INTERIOR ELEVATIONS 12/20/2023

A4-1.10 INTERIOR ELEVATIONS 12/20/2023

A4-1.11 INTERIOR ELEVATIONS 12/20/2023

A5-1.1 PARTITION TYPES 12/20/2023

A5-2.1 DOOR SCHEDULE 12/20/2023

A8-1.0 MILLWORK 12/20/2023

A8-1.1 MILLWORK 12/20/2023

A8-1.2 INTERIOR DETAILS 12/20/2023

A9-1.1 VERTICAL CIRCULATION 12/20/2023

A9-1.2 VERTICAL CIRCULATION DETAILS 12/20/2023

INTERIORS

ID-1.0 MATERIAL LEGEND & ROOM FINISH SCHEDULE 12/20/2023

ID-2.0 WALL FINISH DISTRIBUTION PLAN 12/20/2023

ID-2.1 WALL PROTECTION PLAN 12/20/2023

ID-3.0 FLOOR FINISH DISTRIBUTION PLAN 12/20/2023

ID-4.0 FURNITURE PLAN - FOR REFERENCE ONLY 12/20/2023

FIRE PROTECTION

FP0-0.0 FIRE PROTECTION LEGEND 12/20/2023

FP0-0.1 FIRE PROTECTION DETAILS 12/20/2023

FP2-1.0 BASEMENT - FIRE PROTECTION PLAN 12/20/2023

FP2-1.1 FIRST FLOOR - FIRE PROTECTION PLAN 12/20/2023

FP2-1.2 ROOF - FIRE PROTECTION PLAN 12/20/2023

PLUMBING

P0-0.0 PLUMBING LEGEND 12/20/2023

P0-0.1 PLUMBING SCHEDULES 12/20/2023

P0-0.2 PLUMBING DETAILS 12/20/2023

P1-1.1 FIRST FLOOR - OVERALL PLUMBING PLAN 12/20/2023

P1-1.2 ROOF - OVERALL PLUMBING PLAN 12/20/2023

P2-1.0 UNDERSLAB - NEW DRAINAGE PLAN 12/20/2023

P2-1.1 FIRST FLOOR - NEW DRAINAGE PLAN 12/20/2023

P2-1.2 ROOF DECK - NEW DRAINAGE PLAN 12/20/2023

P2-1.3 TOP OF PENTHOUSE - NEW DRAINAGE PLAN 12/20/2023

P3-1.1 FIRST FLOOR - NEW PLUMBING SUPPLY PLAN 12/20/2023

P3-1.2 ROOF DECK - NEW PLUMBING SUPPLY PLAN 12/20/2023

MECHANICAL

MH0-0.1 HVAC LEGEND AND SCOPE NOTES 12/20/2023

MH0-0.2 HVAC SCHEDULES 12/20/2023

MH0-0.3 HVAC SCHEDULES 12/20/2023

MH0-0.4 HVAC SCHEDULES 12/20/2023

MH1-0.1 FIRST FLOOR - NEW DUCTWORK PLAN 12/20/2023

MH1-0.2 ROOF - NEW DUCTWORK PLAN 12/20/2023

MP2-0.1 FIRST FLOOR - NEW MECHANICAL PIPING PLAN 12/20/2023

MP2-0.2 ROOF - NEW MECHANICAL PIPING PLAN 12/20/2023

MS2-0.1 HVAC OVERALL SITE STEAM UTILITY PLAN 12/20/2023

MS2-0.2 HVAC BUILDING 7 - NEW STEAM PLAN 12/20/2023

MH3-0.0 HVAC BASEMENT - ENLARGED PUMP ROOM VIEW & SECTION 12/20/2023

MH3-0.2 ROOF-ENLARGED PENTHOUSE VIEW & SECTIONS 12/20/2023

MH4-0.1 FIRST FLOOR - HVAC ZONE DIAGRAM 12/20/2023

MH5-0.1 HVAC AIRFLOW DIAGRAM 12/20/2023

MH5-0.2 HVAC HOT WATER PIPING FLOW DIAGRAM 12/20/2023

MH5-0.3 HVAC CHILLED WATER PIPING FLOW DIAGRAM 12/20/2023

MH5-0.4 HVAC STEAM PIPING FLOW DIAGRAM 12/20/2023

MH6-0.1 AHU DETAILS 12/20/2023

MH6-0.2 HVAC DETAILS 12/20/2023

MH6-0.3 HVAC DETAILS 12/20/2023

MH6-0.4 HVAC DETAILS 12/20/2023

MH6-0.5 HVAC DETAILS 12/20/2023

MH6-0.6 HVAC DETAILS 12/20/2023

MH6-0.7 HVAC DETAILS 12/20/2023

MH6-0.8 HVAC DETAILS 12/20/2023

MH6-0.9 HVAC DETAILS 12/20/2023

MH6-0.10 HVAC DETAILS 12/20/2023

MH7-0.1 CONTROLS LEGEND 12/20/2023

MH7-0.2 CONTROLS LEGEND 12/20/2023

MH7-0.3 MIXED AIR AHU DIAGRAM & POINTS LIST 12/20/2023

MH7-0.4 MIXED AIR AHU SEQUENCE OF OPERATION 12/20/2023

MH7-0.5 TERMINAL UNIT DETAILS, POINTS LISTS & SEQUENCE OF OPERATIONS 12/20/2023

MH7-0.6 EXHAUST FAN DIAGRAM, POINTS LIST & SEQUENCE OF OPERATIONS 12/20/2023

MH7-0.7 STEAM TO HOT WATER HEAT EXCHANGER SYSTEM CONTROLS 12/20/2023

MH7-0.8 PACKAGED AIR COOLED CHILLER SYSTEM CONTROLS 12/20/2023

MH7-0.9 MISCELLANEOUS CONTROL DETAILS & POINTS LIST 12/20/2023

MH7-0.10 MISCELLANEOUS SEQUENCES 12/20/2023

ELECTRICAL

E0-0.0 ELECTRICAL LEGEND & GENERAL NOTES 12/20/2023

E1-0.0 ELECTRICAL SITE PLAN 12/20/2023

E1-0.1 ELECTRICAL SITE BUILDING 7 PLAN 12/20/2023

E2-1.1 FIRST FLOOR - NEW LIGHTING PLAN 12/20/2023

E2-1.2 ROOF DECK - NEW LIGHTING PLAN 12/20/2023

E3-2.1 FIRST FLOOR - NEW POWER PLAN 12/20/2023

E3-2.2 ROOF DECK - NEW POWER PLAN 12/20/2023

E4-0.0 ELECTRICAL RISER 12/20/2023

E5-0.0 ELECTRICAL SCHEDULES 12/20/2023

E6-0.0 ELECTRICAL DETAILS 12/20/2023

E6-0.1 ELECTRICAL DETAILS 12/20/2023

E6-0.2 ELECTRICAL DETAILS 12/20/2023

FIRE ALARM

FA0-0.0 FIRE ALARM LEGEND AND DETAILS 12/20/2023

FA1-1.1 FIRST FLOOR - NEW FIRE ALARM PLAN 12/20/2023

FA1-1.2 ROOF DECK - NEW FIRE ALARM PLAN 12/20/2023

NURSE CALL

NC0-0.0 NURSE CALL LEGEND 12/20/2023

NC2-1.1 NURSE CALL FIRST FLOOR PLAN 12/20/2023

NC5-0.1 NURSE CALL DETAILS 12/20/2023

SECURITY

SE0-0.0 SECURITY LEGEND 12/20/2023

SE2-1.1 SECURITY FIRST FLOOR PLAN 12/20/2023

SE5-0.1 SECURITY DETAILS 12/20/2023

SE5-0.2 SECURITY DETAILS 12/20/2023

SE5-0.3 SECURITY DETAILS 12/20/2023

SE5-0.4 SECURITY DETAILS 12/20/2023

SE6-0.1 SECURITY RISERS 12/20/2023

SE7-0.1 SECURITY SCHEDULES 12/20/2023

TELECOMMUNICATION

T0-0.0 COMMUNICATIONS LEGEND 12/20/2023

T2-1.1 COMMUNICATIONS FIRST FLOOR PLAN 12/20/2023

T4-0.1 COMMUNICATIONS FIRST FLOOR PART PLAN AND ELEVATIONS 12/20/2023

T4-0.2 COMMUNICATIONS FIRST FLOOR RACK ELEVATION 12/20/2023

T5-0.1 COMMUNICATIONS DETAILS 12/20/2023

T5-0.2 COMMUNICATIONS DETAILS 12/20/2023

T5-0.3 COMMUNICATIONS DETAILS 12/20/2023

T6-0.1 COMMUNICATIONS RISER DIAGRAMS 12/20/2023

T6-0.2 COMMUNICATIONS GROUNDING RISER DIAGRAM 12/20/2023

Revisions: Date:

CONSTUCT SPECIALTY

CARE BUILDING

DNDN

DN

UP

DN

DN

5.7

D

1.3

E C B AB.9C.5C.9

A.2

A.96A.95 A.65 A.45 AA

5.5

5.8

5.9

B.2

B.4 A.8 aa bb cc

EXAM 2 LOW VISION

EXAM

SWA130

EXAM 3

SWA131

EXAM 5

SWA133

EXAM 6

SWA134

EXAM 7

SWA140

EXAM 8

SWA141

EXAM 9

SWA142

EXAM 10

SWA143

EXAM 11 BARIATRIC

SWA144

VISUAL FIELDS

SWA155

EXAM 12 PRETEST

SWA149

OPTOMETRY SERVICE

CHIEF

SWA150

LOUNGE

SWA139

STAFF TOILET

SWA137

STAFF TOILET

SWA136

WATER SERVICE

SWA122

SOILED

SWA135

TR

SWA121

AUDIO SERVICE CHIEF

SWA113

HEARING AID

PROCESSING

SWA126

PROCEDURE

SWA125

HEARING AID

MODIFICATION

SWA127

WORK STATIONS (4)

SWA112

AUDIO TECH

SWA117

TOIL

SWA103

CERUMEN

MANAGMENT

SWA119

PROGRAMMING AND

FITTING ROOM

SWA120

AUDIO BOOTH EXAM

SWA114A

VESTIBULOGRAPHY /

TELEHEALTH

SWA124

EXAM 4

SWA132

PROGRAMMING

FITTING ROOM

SWA111

PROGRAMMING

FITTING ROOM

SWA110

PROGRAMMING

FITTING ROOM

SWA109

PROGRAMMING

FITTING ROOM

SWA108

LARGE AUDIO BOOTH

EXAM

SWA106A

PATIENT LIFT

STORAGE

SWA138

REF.

LOCKERS

CONTROL

SWA114

AUDIO BOOTH EXAM

SWA115A

CONTROL

SWA115

CONTROL

SWA116

LARGE AUDIO BOOTH

CONTROL

SWA106

EQUIPMENT

SWA107

STAIRS

SWA102

CLEAN SUPPLY

SWA118

CORRIDOR

SWA160C

CORRIDOR

SWA161

EMERGENCY ELEC

SWA105A

TOIL

SWA104

H.A.C

SWA123

HEALTH TECHS WKSTA

SWA153

CORRIDOR

SWA160A

REF. OMNI

CELL

RME

EXISTING BUILDING No. 18

EXIST 2 HOUR FIRE RATED SEPARATION

BETWEEN BUILDINGS 1 AND 18

VEST

EXIST 2 HOUR FIRE RATED SEPARATION

CONTINUOUS AROUND VESTIBULE

EXISTING

BUILDING No. 1

EXISTING

PRIMARY CARE

CLINIC

(BUSINESS OCCUPANCY)

PROPOSED NEW ADDITION

(BUSINESS OCCUPANCY)

WAITING AREA

DN

LOBBY

EMERG

ELEC

ELEC

MEN

WOMEN

KITCHENETTE

GROUP ROOM MH EXAM

MH EXAMMH EXAMMH EXAM

CORR

CORR

CORR

MH EXAMMH EXAMMH EXAM

MH EXAMMH EXAMMH EXAM

MH EXAMMH EXAMMH EXAM

OMNI CELL

MH EXAMMH EXAM

MH EXAMMH EXAMMH EXAM

PAT

TOILPC EXAMPC EXAM

ROOF ACCESS

CORR

CORR

CORR

CORR

CORR

PC EXAM

TEAMLET

CORR

PC EXAMPC EXAMPC EXAM TEAMLETTEAMLET

PC EXAM

PC EXAM

STAFF

TOIL

HSKPG

EQUIP

CLEAN

SUPPLY

SOILED

PC EXAMPC EXAM PC EXAM

CENTRAL

TRIAGE

CENTRAL

TRIAGE

PAT

TOIL

COPY/

MAIL

REGISTRATION

PAT

TOIL

STAFF

TOIL

EXIT

EXIT

EXIT

EXIT

NEW ADDITION TOTAL

EXIT CAPACITY:

3 EXITS TOTALING

510 OCCUPANTS

EXIT CAPACITY:

DOOR 34" CLEAR / 0.2" =

170 OCCUPANTS

13 occupants

1 occupant

1 occupant

EXIT ACCESS DOOR SERVES

24 OCCUPANTS (WHICH IS LESS THAN

50, THEREFORE DOOR CAN SWING IN)

TO OTHER EXITS

TO OTHER EXITS

EXIT CAPACITY:

DOOR 34" CLEAR / 0.2" =

170 OCCUPANTS

EXIT CAPACITY:

DOOR 34" CLEAR / 0.2" =

170 OCCUPANTS

6'

6' - 0"

6'

6' - 0"

6' - 0"

6'

6' - 0"

6'

6'

STAIRS SERVE

ONLY AS

ACCESS TO

PENTHOUSE.

NOT AN EXIT

S

S

S

OCCUPANT LOAD = 189 OCCUPANTS

110FT 117FT

122FT

116FT

FEC

FECFEC

FE

C

FE

C

FE

C

FE

C

FEC

FEC

F E

C

F E

C

EXISTING AREA = 12,903 SF

OCCUPANT LOAD = 247 OCCUPANTS

EXIST EXIT CAPACITY:

EXIST DOOR 68" CLEAR / 0.2"

= 340 OCCUPANTS

F E

C

S

ELEC

SWA105

A B C D ED.3

1.2

1.6

3.4

D.6C.2 eDeE e1 e2 e3 e4 e5 eC.9 e5.7

OFFICE

SWA152

WORK STATIONS (4)

SWA151

CONFERENCE ROOM

SWA154

AUDIO BOOTH EXAM

SWA116A

VESTIBULE

SWA100

S

S

IMAGING

SWA148

OPTICAL

SWA128

EXAM 1 LASER &

PROCEDURE

SWA129

RECEPTION

SWA145

RECEPTION

SWA145A

CLEAN

SWA146

STOR

SWA147

WAITING

SWA101

CORRIDOR

SWA160F

CORRIDOR

SWA160D

CORRIDOR

SWA160C

CORRIDOR

SWA160E

4 occupants

7 occupants

GENERAL NOTES - LIFE SAFETY PLAN

1. CONTRACTOR TO ENSURE THAT FIRE SEPARATION BETWEEN

EXISTING BUILDING AND ADDITION IS MAINTAINED THROUGHOUT

CONSTRUCTION.

VA DIRECTIVES, DESIGN MANUALS, MASTER SPECIFICATIONS, AND VA NATIONAL CAD

STANDARD APPLICATION GUIDE (TIL)

2021 NFPA 101 LIFE SAFETY CODE

2021 NFPA 1 FIRE CODE

2022 OCCUPATIONAL, SAFETY and HEALTH ADMINISTRATION (OSHA) STANDARDS

2020 VA SEISMIC DESIGN REQUIREMENTS (H-18-8)

2021 INTERNATIONAL PLUMBING CODE (IPC)

2022 NFPA 10 STANDARD FOR PORTABLE FIRE EXTINGUISHERS

2022 NFPA 13 INSTALLATION OF SPRINKLER SYSTEMS

2021 NFPA 54 NATIONAL FUEL GAS CODE

2023 NFPA 70 NATIONAL ELECTRICAL CODE (NEC)

2022 NFPA 72 NATIONAL FIRE ALARM AND SIGNALING CODE

2022 NFPA 80 STANDARD FOR FIRE DOORS AND OTHER OPENING PROTECTIVES

2021 NFPA 99 STANDARDS FOR HEALTH CARE FACILITIES

ARCHITECTURAL BARRIERS ACT ACCESSIBILITY STANDARDS (ABAAS)

VA SUPPLEMENT BARRIER FREE DESIGN GUIDE (PG-18-13)

AMERICAN CONCRETE INSTITUTE AND COMMENTARY (ACI 318)

AMERICAN INSTITITUTE OF STEEL CONSTRUCTION (AISC)

2005 ENERGY POLICY ACT

DEPT OF ENERGY INTERIM FINAL RULE: ENERGY CONSERVATION STANDARDS FOR NEW

FEDERAL, COMMERCIAL AND MULTI-FAMILY HIGH-RISE RESIDENTIAL BUILDINGS AND NEW

LOW-RISE RESIDENTIAL BUILDINGS

2004 VENTILATION FOR ACCEPTABLE INDOOR AIR QUALITY - ASHRAE STANDARD 62-1

2007 SAFETY STANDARD FOR REFRIGERATION SYSTEMS - ASHRAE STANDARD 15

2021 INTERNATIONAL BUILDING CODE - Only when specifically referenced in VA Design Guide

APPLICABLE CODES:

LIFE SAFETY LEGEND

RATED CONSTRUCTION IS INDICATED AS FOLLOWS:

1HR FIRE RATED BARRIER

2HR FIRE RATED BARRIER

PARTITION THAT LIMITS TRANSFER OF SMOKE

PATH OF EXIT TRAVEL

DISTANCE TO EXIT FROM REMOTE POINT ON FLOOR

OR COMMON PATH OF TRAVEL

INDICATED EXIT LOCATION

FIRE EXTINGUISHER CABINET

FIRE VALVE CABINET (HOSE CONNECTION)

FEC

XXX'

CONTRACTOR TO VERIFY EXISTING WALL CONSTRUCTION MATCHES FIRE/SMOKE

RATING AS INDICATED ON PLAN AND NOTIFY ARCHITECT OF ANY DISCREPANCIES.

WHERE EXISTING CONDITIONS HAVE BEEN COMPROMISED THE CONTRACTOR

SHALL NOTIFY THE ARCHITECT AND OWNER OF ANY DISCREPANCIES.

1.

2.

CONTRACTOR IS RESPONSIBLE FOR INTEGRITY OF EXISITNG RATED

PARTITIONS AS A RESULT OF THIS WORK THROUGHOUT THE PROJECT.

3.

EXIT

FVC

FIRE RATED DOOR RATINGS4.

EXIT SIGN: AT EXIT (ONE SIDED)

EXIT SIGN: EXIT DIRECTION (ONE SIDED)

EXIT SIGN: MULTIPLE EXIT DIRECTION (ONE SIDED)

EXIT SIGN: TWO FILLED QUADRANTS INDICATE

TWO SIDED SIGN (HATCHED AREAS INDICATE

DIRECTIONS SIGN IS VISIBLE FROM)

FEC

FE

FEC

FIRE EXTINGUISHERS: (LOCATED NOT MORE THAN 75 FOOT TRAVEL

DISTANCE FROM ANY POINT IN THE FACILITY)

6.

EXIT SIGNS: (LOCATIONS SUBJECT TO AUTHORITY HAVING JURISDICTION)5.

FIRE RATING OF DOOR (IN MINUTES)45

SMOKE RATED DOORS

CLASSIFICATION / FIRE RATING SCHEDULE

CONSTRUCTION CLASSIFICATION: NFPA 101: TYPE II (222)

IBC: TYPE IB

ELEMENTS

PRIMARY FRAMING

HOURLY

RATING

FIRE RESISTIVE

DESIGN NO.

RESTRAINED LOCATION/

REMARKS

OCCUPANCY CLASSIFICATION: B - BUSINESS (OUTPATIENT CLINIC)

AUTOMATIC SPRINKLER PROTECTION: FULLY SPRINKLERED FACILITY

HRS.2 N/A

STEEL FRAME W/ SPRAY

FIREPROOFING

FLOOR CONSTRUCTION HRS.2 YES

CONC SLAB ON GRADE &

CONCRETE COMPOSITE

AT PENTHOUSE

D902

ROOF CONSTRUCTION HRS.1 YESP801

CORRIDORS HRS.0 N/A

EXIT ENCLOSURES

(EXISTING STAIRS) HRS.1 N/A

SHAFT ENCLOSURES HRS. N/AN/A

HAZARDOUS SPACES HRS.0 N/AU419

X829

RESIST THE PASSAGE

OF SMOKE ONLY

STEEL DECKING W/

SPRAY FIREPROOFING

N/A

N/A

IEBC CLASSIFICATION: NEW ADDITION &

LEVEL 2 ALTERATION- BASED ON THE WORK AREA METHOD

THE EXISTING FACILITY, KNOWN AS THE VETERANS ADMINISTRATION MEDICAL CENTER AND

LOCATED AT 718 SMYTH ROAD IN MANCHESTER, NEW HAMPSHIRE IS A SIX STORY MEDICAL

COMPLEX WITH MIXED OCCUPANCIES. THE EXISTING BUILDING WHERE THE PROPOSED ADDITION

OCCURS IS CONSTRUCTED OF A PROTECTED STEEL FRAME STRUCTURE WITH CONCRETE

COMPOSITE FLOORS WHICH CLASSIFIES THE BUILDING AND NEW ADDITION AS CONSTRUCTION

TYPE II (222) PER THE LIFE SAFETY CODE NFPA 101 AND TYPE IB PER THE INTERNATIONAL

BUILDING CODE.

THE PROPOSED ONE STORY ADDITION OCCURS ADJACENT AND ATTACHED TO THE BUSINESS

OCCUPANCY PORTION OF THE OVERALL FACILITY WHICH IS SEPARATED FROM THE REST OF THE FACILITY WITH EXISTING FIRE RATED CONSTRUCTION. THE NEW ADDITION WILL BE USED AS AN

EXTENSION OF THE BUSINESS OCCUPANCY AND THEREFORE DOES NOT NEED TO BE

SEPARATED FROM THE EXISTING.

THE FOOTPRINT AREA OF THE NEW ADDITION EQUALS APPROXIMATELY 13,380 SF OF SPACE ON THE FIRST FLOOR ONLY. THE TOTAL AREA OF WORK IS LESS THAN 50% OF THE EXISTING FIRST

FLOOR AS A WHOLE AND THEREFORE ANY RELATED RENOVATION WORK IS CONSIDERED A

LEVEL 2 ALTERATION.

THE EXISTING FACILITY IS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM.

THE OVERALL EXISTING FACILITY IS 6 STORIES ABOVE GRADE AND AT LESS THAN 75 FEET IN

HEIGHT, IT IS NOT CONSIDERED A HIGH RISE.

EXISTING BUILDING ASSESSMENT

(less than 50% of existing building area)

BUILDING HEIGHT:

EXIST BUILDING IS 6 STORIES ABOVE GRADE

NEW ADDITION IS 1 STORY ABOVE GRADE ONLY

SERVE < 3 STORIES

EXIST STAIRS NOT IN

SCOPE OF WORK

SERVE < 3 STORIES

EXIST NOT IN SCOPE

OF WORK

TRAVEL DISTANCE TO EXITS 300 FEET MAX

COMMON PATH OF TRAVEL 100 FEET MAX

DEAD END CORRIDORS 50 FEET MAX

TRAVEL DISTANCE REQUIREMENTS

OCCUPANT LOAD - GROUND FLOOR

DESCRIPTION USE GROUP (TABLE 1004.1.1) FLOOR AREA OCCUPANT LOAD

11,175 SF 112 OCCUPANTS

WAITING AREA 790 SF 24 OCCUPANTS

STORAGE ROOMS,

MECH & ELEC SPACES 865 SF 53 OCCUPANTS

ACCESSORY ASSEMBLY USE (UNCONCENTRATED)

(15 NET SF/PERSON)

189 OCCUPANTSTOTAL OCCUPANT LOAD FOR NEW ADDITION 12,830 SF

PRIMARY OCCUPANCY

BUSINESS USE / OUTPATIENT USE

(100 GROSS SF/PERSON)

ACCESSORY STORAGE USE

(300 GROSS SF/PERSON)

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

ARCHITECT STAMPCONSULTANT

321 4 5 6 7 8 9 10

129 South St, 2nd floor Boston, MA 02210

T: 617.772.0260 F: 617.772.0261 www.e4harchitecture.com

FINAL FOR

CONSTRUCTION

FULLY SPRINKLERED

STRUCTURAL MEP / FP

Simpson Gumpertz & Heger 480 Totten Pond Road Waltham, MA 02451

T: 781.907.9000 sgh.com

BR+A

10 Guest Street, 4th FLR Boston, MA 02135

T: 617.254.0016 brplusa.com

CIVIL

Meridian Associates, Inc.

500 Cummings Center, Suite 5950 Beverly, MA 01915

T: 978.299.0447 meridianassoc.com

B

IM

/V

A M

C M a n c h e s te r S p e c ia lt y C lin ic

/V A

M C

M

A N

C H

E S

T E

R S

P E

C C

L

IN

IC

R

.r v t

/1 /2

:0

:2

A M

AG-1.3

FIRST FLOOR LIFE SAFETY PLAN

718 Smyth Rd, Manchester, NH 03104

608-315

12/20/2023

SCALE: 1/8" = 1'-0"1

FIRST FLOOR LIFE SAFETY PLAN

0' 2' 4' 8' 16'

NORTH

Revisions: Date:

CONSTUCT SPECIALTY

CARE BUILDING

6 SPACES

GAS

G

AS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

G

AS

G

AS

GAS

GAS

GAS

GAS

GAS

GAS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

GAS

GAS

GAS

NST

NST

NST

N

ST

PHASE TWO

6" ST

4" CND

MP101

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

NW

NW

NW

H Y

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N-SD

N-

SD

N-

SD

N-SD

N-SD

NSD

N-

SD

N-

SD

SD

SD

SDSDSD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD SD

SD

SD

SD

SD

SD SD

WG

WG

W

GSP

W

GSP

W G

WG

W G

W

GWG

W G

WG

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

WG

W W

W W

W W

W

W

W W

W

W

W

W

W

W W

W

WWWWWWWWWWWWW

W

W W

W W

W

WWWWWWWWWWWWW

W

W W

W W

W

WWW

W W

W

W

W

W

W

W

W W

N W

NW

NWNW

NW

N W

NW

NW

U G

C

UGC

UGC

UGC

UGC

UGC

UGC

U G

C

UG

C

UGC

GG

GG

GGSP

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UG

E

U G

E

U G

E

UGE

U G

E

U G

E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

U G

E

U G

E

U G

E

UG

E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

E

UGEUGEUGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

U G

E U

G E

UGE

UGEUGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE UGE UGE

UG

E

UG

E

UG

E

UG

E

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

UGE

UGE

U G

E

U G

E

U G

E

U G

E

UGE

UGE

UGE

UGE

UGE

E & FA Q

L-B

1"

E Q

L- B

1"

E Q

L- B

2-4" E (E

MPTY) Q

L-B

2-4" E

QL-B

2- 4"

E Q

L- B

1"± E Q L-B

2-4" E Q

L-B

2-4" E QL-B

2- 4"

E Q

L- B

2-4" PVC E QL-B

1"± E

Q L-B

1"± E QL-B

2-3" (R) E QL-B

5- 4"

-1 " E

/T /F

A Q

L- B

4" E

QL-B

2-3" E QL-B

2-2" E QL-B

EO

I

E Q

L- B

E QL-B

E QL-B

2"

IP

E Q

L- B

4-4" PVC E QL-B

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

S

S

S

S

S

S

S

S

S

S

S S S S S S SSS

SS

474473

5 46

SS

SS

SS

SS

W

W W

W W W

W

W W W

UGE

UGE

UGEUGEUGEUGE

UGE

UGEUGEUGE

U G

E

UG

E

UG

E

UG

E

U G

E

UGE

UGE

UG

E

U G

E U

G E

UG

E

UG

E

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE UGE

UGE

UGE

UGE

UGE

UGE

SD

SD

SD

SD

SD

SD

SD

E

E a b

ENTIRE RETAINING

WALL TO BE REMOVED

8" DI WATER LINE

TO BE REMOVED/

RELOCATED. SEE

UTILITY PLAN.

ELECTRIC DUCT BANK

TO BE REMOVED/

RELOCATED. SEE

UTILITY PLAN.

TRANSFORMER

TO BE

RELOCATED

ELECTRIC MANHOLE

TO BE REMOVED

LIGHT POLE AND

ASSOCIATED ELECTRIC

LINES TO BE REMOVED

LIMIT OF WORK

CONCRETE STAIRS

TO BE REMOVED

PORTION OF WALKWAY TO

BE REMOVED. SEE LAYOUT

AND MATERIALS PLAN.

PROPOSED

FILTER SOCK

ELECTRIC DUCT BANK

TO BE REMOVED/

RELOCATED. SEE

UTILITY PLAN.

PROPOSED

SAWCUT

PROPOSED

SAWCUT

PROPOSED

SAWCUT

PROPOSED

FILTER BAG

PROPOSED

FILTER BAG

TREE TO BE

REMOVED

(TYP.)

PROPOSED

CONSTRUCTION

ENTRANCE

PROPOSED TREE

PROTECTION

(TYP.)

PROPOSED

SAWCUT

X X X

ELECTRIC DUCT BANK

TO BE REMOVED/

RELOCATED. SEE

UTILITY PLAN.

LIMIT OF WATER LINE

TO BE REMOVED/

RELOCATED. SEE

UTILITY PLAN.

ELECTRIC DUCT BANK

TO BE REMOVED/

RELOCATED. SEE

UTILITY PLAN. LIMIT OF ELEC. LINE TO

BE REMOVED/

RELOCATED. SEE

UTILITY PLAN.

LIMIT OF WATER LINE

TO BE REMOVED/

RELOCATED. SEE

UTILITY PLAN.

X

PAVEMENT TO

BE REMOVED

PROPOSED

SAWCUT (TYP.)

LIMIT OF WORK

X

LIMIT OF

WORK

PROPOSED

SAWCUT

PROPOSED

SAWCUT (TYP.)

PROPOSED

SAWCUT

(TYP.)

BUILDING #7

PROPOSED

FILTER SOCK

PROPOSED

SAWCUT

SCALE: 1" = 20'

60'40'20'20' 010'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DSK DSKRevisions: Date:

Boston, MA 02210

T: 617.772.0260 F: 617.772.0261 www.e4harchitecture.com

FINAL FOR

CONSTRUCTION

FULLY SPRINKLERED

STRUCTURAL MEP / FP

DESIGN SPECIALTY

CARE BUILDING

718 Smyth Road, Manchester, NH 03104

608-315

Simpson Gumpertz & Heger 41 Seyon Street Waltham, MA 02453

T: 781.907.9000 sgh.com

BR+A

10 Guest Street, 4th

FLR

Boston, MA 02135

T: 617.254.0016 brplusa.com

CIVIL

Meridian Associates 500 Cummings Center Suite 5950 Beverly, MA 01915

T: 978.299.0447 meridianassoc.com 12/20/2023

129 South St, 2nd floor

ARCHITECT

EXISTING CONDITIONS & SITE

DEMOLITION PLAN

C-1.0

DEMOLITION LEGEND:

LIMIT OF WORK

FILTER SOCK

REMOVE & DISPOSE R&D

TO BE RELOCATED TB-RELO

TO BE REMOVED TBR

REMOVE & STOCKPILE R&S

SAWCUT

TREE PROTECTION

TREE TO BE REMOVED

UTILITY TO BE REMOVED

SOIL EROSION & SEDIMENTATION CONTROL NOTES:

1. THE LOCATION OF EROSION CONTROL BARRIERS SHOWN ON DRAWINGS ARE INTENDED TO BE MINIMUM REQUIREMENTS AND A

GUIDE FOR THE PLACEMENT OF THESE BARRIERS. OTHER MEASURES MAY BE WARRANTED BASED UPON EXPERIENCE AT THE SITE.

WHEN NO SEDIMENTATION CONTROL SYSTEM IS SHOWN ON THE DRAWING, THE CONTRACTOR SHALL BE REQUIRED TO ESTABLISH A SYSTEM TO PREVENT SILTATION OR POLLUTION OF ADJACENT PROPERTIES AND/OR WETLAND RESOURCE AREAS. THE SYSTEMS SHOWN SHALL NOT RELIEVE THE CONTRACTOR FROM THE RESPONSIBILITY OF PLACING ADDITIONAL BARRIERS OR REPLACING BARRIERS AS REQUIRED BY SITE CONDITIONS. THE IMPLEMENTATION, MAINTENANCE, REPLACEMENT AND ADDITIONS TO THESE SYSTEMS SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR. AS CONSTRUCTION PROGRESSES AND SEASONAL CONDITIONS DICTATE, MORE SILTATION CONTROL FACILITIES MAY BE REQUIRED. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO

ADDRESS NEW CONDITIONS THAT MAY BE CREATED.

2. SUITABLE SEDIMENTATION CONTROL FACILITIES MUST BE CONSTRUCTED, CLEARLY VISIBLE, AND IN OPERATION PRIOR TO

CONSTRUCTION.

3. ANTI-TRACKING PADS SHALL BE ESTABLISHED AT ALL POINTS OF INGRESS AND EGRESS.

4. CONSTRUCTION STAGE STORMWATER MANAGEMENT SHALL BE PROVIDED BY TEMPORARY DIVERSIONS AND SEDIMENT BASINS

SIZED IN ACCORDANCE WITH STATE AND USEPA STANDARDS.

5. TEMPORARY DIVERSION DITCHES, EMBANKMENTS AND ANY DENUDED SURFACE WHICH WILL BE EXPOSED FOR A PERIOD OF ONE MONTH OR MORE SHALL BE CONSIDERED CRITICAL STABILIZATION AREAS. THESE AREAS SHALL BE MULCHED WITH STRAW.

MULCH SHALL BE SPREAD UNIFORMLY IN A CONTINUOUS BLANKET OF SUFFICIENT THICKNESS TO COMPLETELY HIDE THE SOIL

FROM VIEW.

6. SEDIMENT CONTROL MEASURES SHALL BE PROVIDED AROUND ALL EXISTING AND PROPOSED DRAINAGE STRUCTURES AS DETAILED

ON THE DRAWINGS OR AS REQUIRED TO PREVENT SEDIMENTATION.

7. HAYBALES, SILT FENCE OR OTHER SILTATION CONTROLS SHALL BE MAINTAINED IN A SATISFACTORY CONDITION UNTIL CONSTRUCTION IS COMPLETED AND THE POTENTIAL FOR ON-SITE EROSION HAS PASSED. THE CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVAL OF ALL SILTATION CONTROLS. THE CONTRACTOR SHALL NOT REMOVE ANY SILTATION CONTROLS

UNTIL AUTHORIZED (IN WRITING) BY THE OWNER OR HIS REPRESENTATIVE.

8. EROSION AND SEDIMENTATION CONTROL MEASURES SHALL BE INSPECTED AND MAINTAINED ON A WEEKLY BASIS AND AFTER EACH STORM EVENT OF 0.25 INCH OR GREATER DURING CONSTRUCTION TO ENSURE THAT CHANNELS, DITCHES AND PIPES ARE

CLEAR OF DEBRIS AND THAT THE EROSION CONTROL BARRIERS ARE INTACT.

9. THE CONTRACTOR SHALL MAINTAIN A SUFFICIENT RESERVE OF VARIOUS EROSION CONTROL MATERIALS ONSITE AT ALL TIMES FOR

EMERGENCY PURPOSES OR ROUTINE MAINTENANCE.

10. LOAMING AND SEEDING OR MULCHING OF NON-PAVEMENT AREAS SHALL TAKE PLACE AS SOON AS PRACTICABLE.

11. ALL STOCKPILE AREAS SHALL BE LOCATED WITHIN LIMIT OF WORK AND STABILIZED TO PREVENT EROSION.

12. USE MEANS NECESSARY TO PREVENT DUST FROM BECOMING A NUISANCE TO THE PUBLIC, TO NEIGHBORS, AND TO OTHER WORK

BEING PERFORMED ON OR NEAR THE SITE

13. THE CONTRACTOR SHALL PERFORM EFFECTIVE SEQUENCING OF CONSTRUCTION ACTIVITIES TO MINIMIZE DISTURBED AREAS ON

THE SITE. THE SEQUENCE SHALL BE GENERALLY AS FOLLOWS:

13.1. INSTALL ALL EROSION AND SEDIMENT CONTROLS.

13.2.REMOVE AND DISPOSE OF ALL PAVEMENT TO BE REMOVED. LOAM & SEED DISTURBED AREAS.

13.3.PERFORM CLEARING AND GRUBBING.

13.4. STRIP TOPSOIL AND PERFORM EXCAVATION AND GRADING.

13.5.REMOVE AND DISPOSE OF STRUCTURES TO BE REMOVED.

13.6. INSTALL DRAINAGE, UTILITIES AND ASSOCIATED STRUCTURES.

13.7. CONSTRUCT BUILDING AND ASSOCIATED IMPROVEMENTS.

13.8.PERMANENTLY STABILIZE ALL DISTURBED AREAS AND INSTALL LANDSCAPING AND ASSOCIATED APPURTENANCES.

13.9.REMOVE ALL SOIL AND EROSION CONTROLS AFTER SITE HAS BEEN STABILIZED.

14. A MINIMUM OF SIX (6) INCHES OF TOPSOIL SHALL BE PLACED ON ALL DISTURBED SURFACES WHICH ARE PROPOSED TO BE

PLANTED.

15. ANY AREA THAT IS DISTURBED AND LEFT IDLE FOR MORE THAN 14 DAYS SHALL BE IMMEDIATELY STABILIZED BY TEMPORARY VEGETATION OR OTHER EROSION CONTROL MEASURE APPROVED BY THE CONSERVATION COMMISSION OR ITS AGENT.

16. A SUPPLY OF EROSION CONTROL BARRIER MATERIALS SHALL BE KEPT ON SITE TO REPLACE AND/OR REPAIR BARRIERS THAT ARE

DAMAGED OR DEGRADED.

17. INSTALL SILT SACK IN CATCH BASINS AT ALL PAVEMENT REMOVAL AREAS.

18. DEWATERING WASTEWATER PUMPED FROM EXCAVATIONS WILL BE CONVEYED BY HOSE TO AN UPLAND AREA AND DISCHARGED INTO A DEWATERING BASIN HAY BALE CORRALS, OR SEDIMENTATION BAGS. THE CONTRACTOR SHALL TEST THE DEWATERING WASTEWATER FOR CONTAMINANTS PRIOR TO DISCHARGING. THE CONTRACTOR IS RESPONSIBLE FOR ALL ENGINEERING, EQUIPMENT, MATERIAL, AND LABOR REQUIRED FOR THIS PROJECT PROPOSED SITE WATER REMOVAL DURING CONSTRUCTION.

19. ALL DRAINAGE STRUCTURES SHALL BE CLEARED OF ACCUMULATED SEDIMENT PRIOR TO ACCEPTANCE OF THE FINAL PROJECT.

SITE DEMOLITION NOTES:

1. CONTRACTOR SHALL PROVIDE AND MAINTAIN PROTECTIVE MEASURES FOR PEDESTRIAN SAFETY AROUND EXCAVATIONS AND

CONSTRUCTION ACTIVITIES. SUCH MEASURES MAY INCLUDE CONSTRUCTION FENCING, STEEL PLATING, FLAGMEN AND FLASHING

BARRELS.

2. CONTRACTOR SHALL PROVIDE SAFE PEDESTRIAN ACCESS TO ADJACENT BUILDINGS DURING CONSTRUCTION PERIOD.

3. ALL REMOVED, NON-SALVAGEABLE MATERIAL SHALL BE DISPOSED OF OFF-SITE BY CONTRACTOR, AT NO COST TO THE OWNER, IN

ACCORDANCE WITH LOCAL AND STATE REGULATIONS.

4. CONSTRUCTION SITE WASTE MATERIALS WILL BE PROPERLY CONTAINED ONSITE AND DISPOSED OFF SITE AT A LOCATION IN

ACCORDANCE WITH THE LOCAL AND STATE REGULATIONS.

5. SAWCUT PAVEMENTS AT ALL EDGES OF WORK WHERE NEW WORK TO ABUT EXISTING PAVEMENTS.

6. THE CONTRACTOR SHALL COORDINATE ALL DEMOLITION OF STRUCTURES, PAVEMENT AND CONCRETE MATERIALS, AND UTILITIES WITH APPROPRIATE PROPOSED SITE GENERAL, UTILITY, LANDSCAPING, AND ARCHITECTURAL DRAWINGS.

7. ALL NOTED UTILITIES TO BE REMOVED AND DISPOSED OF, RELOCATED OR CAPPED REPRESENT ALL KNOWN SITE CONDITIONS TO BE DEMOLISHED. CONTRACTOR TO COORDINATE ALL UNFORESEEN CONDITIONS WITH THE PROJECT ENGINEER, ARCHITECT AND/OR

RESPECTIVE UTILITY COMPANIES PRIOR TO PROCEEDING WITH WORK.

8. WATER, SEWER, DRAINAGE AND OTHER SITE UTILITIES SERVICING THE EXISTING FACILITIES ARE TO REMAIN ACTIVE UNTIL PROPOSED IMPROVEMENTS ARE CONSTRUCTED AND ONLINE. WHEN CONNECTING TO ACTIVE OR RELOCATED UTILITIES, SHUTDOWNS SHALL BE MINIMIZED AND COMPLETED OFF HOURS AND COORDINATED WITH THE OWNER.

X

NOTES:

1. EXISTING CONDITIONS PLAN TAKEN FROM FIELD SURVEY PERFORMED BY DOUCET SURVEY INC. 102 KENT PLACE, NEWMARKET, NH

03057, 603-659-6560 DURING DECEMBER 2016 AND MAY 2017 USING TRIMBLE S6, S7 & 5603 TOTAL STATIONS WITH TRIMBLE TSC3 DATA COLLECTORS AND A SOKKIA B21 AUTO LEVEL. TRAVERSE ADJUSTMENTS BASED ON LEAST SQUARES, AND DuBOIS & KING

PLANS DATED JUNE 2017.

2. HORIZONTAL DATUM BASED ON NEW HAMPSHIRE STATE PLANE(2800) NAD83(2011) DERIVED FROM REDUNDANT GPS

OBSERVATIONS UTILIZING THE KEYNET GPS VRS NETWORK.

3. VERTICAL DATUM IS BASED ON APPROXIMATE NAVD88(GEOID12A) (±.2') DERIVED FROM REDUNDANT GPS OBSERVATIONS UTILIZING

THE KEYNET GPS VRS NETWORK.

4. UNDERGROUND UTILITIES SHOWN HEREON ARE BASED ON OBSERVABLE PHYSICAL EVIDENCE AND PAINT MARKS FOUND ON-SITE, AND INFORMATION SHOWN ON REFERENCE PLAN 5. REFER TO DRAWING LEGEND FOR ADDITIONAL INFORMATION.

5. THE ACCURACY OF MEASURED UTILITY INVERTS AND PIPE SIZES/TYPES IS SUBJECT TO NUMEROUS FIELD CONDITIONS, INCLUDING;

THE ABILITY TO MAKE VISUAL OBSERVATIONS, DIRECT ACCESS TO THE VARIOUS ELEMENTS, MANHOLE CONFIGURATION, ETC.

6. ALL ELECTRIC, GAS, TEL. WATER, SEWER AND DRAIN SERVICES ARE SHOWN IN SCHEMATIC FASHION, THEIR LOCATIONS ARE NOT PRECISE OR NECESSARILY ACCURATE. NO WORK WHATSOEVER SHALL BE UNDERTAKEN ON THIS SITE USING THIS PLAN TO LOCATE THE ABOVE SERVICES. CONSULT WITH THE PROPER AUTHORITIES CONCERNED WITH THE SUBJECT SERVICE LOCATIONS FOR INFORMATION REGARDING SUCH. CALL DIG-SAFE AT 1-888-DIG-SAFE AND PRIVATE UTILITY LOCATE COMPANY TO PROPERLY

DEMARCATE EXISTING ONSITE UTILITIES.

7. THIS PLAN WAS PREPARED FROM RECORD RESEARCH, OTHER MAPS, LIMITED FIELD MEASUREMENTS AND OTHER SOURCES. IT IS NOT TO BE CONSTRUED AS A PROPERTY / BOUNDARY SURVEY AND IS SUBJECT TO SUCH FACTS AS SAID SURVEYS MAY DISCLOSE.

December 20, 2023

CONSTUCT SPECIALTY

CARE BUILDING

21 SPACES

WG

W

GSP

W

GSP

W G

W G

WG

W G

WG

PROPOSED DESIGN SPECIALTY CARE BUILDING

FINISHED FLOOR ELEVATION = 467.5

PROPOSED CONCRETE RAMP

WITH HANDRAILS

(REFER TO ARCHITECTURAL

DRAWINGS FOR DETAILS)

PROPOSED

TRANSFORMER ON

CONCRETE PAD

WITH BOLLARDS

PROPOSED 6' WIDE

CONCRETE WALKWAY

PROPOSED

INTERLOCKING BLOCK

RETAINING WALL

(TOP TO EXTEND 6" AFG)

T

LIMIT OF WORK

PROPOSED

VERTICAL GRANITE

CURB (VGC - TYP.)

PROPOSED EDGE

OF SIDEWALK

PROPOSED

SIDEWALK

6' 2' 10

M

IN

LIMIT OF WORK

3'

PROPOSED 2'

WIDE STONE DRIP

EDGE (TYP.)

PROPOSED

TRANSFORMER ON

CONCRETE PAD

T

COBBLE STONE OR

VERTICAL GRANITE

CURBING (TYP.)

COBBLE STONE OR

VERTICAL GRANITE

CURBING (TYP.)

COBBLE STONE OR

VERTICAL GRANITE

CURBING (TYP.)

LIMIT OF

WORK

PROPOSED

CONCRETE

WALKWAY

PROPOSED CONCRETE RAMP

WITH HANDRAILS

(REFER TO ARCHITECTURAL

DRAWINGS FOR DETAILS)

PROPOSED

PAVEMENT

51'±

VGC

VG

C

VG

C

SCALE: 1" = 20'

60'40'20'20' 010'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DSK DSKRevisions: Date:

Boston, MA 02210

T: 617.772.0260 F: 617.772.0261 www.e4harchitecture.com

FINAL FOR

CONSTRUCTION

FULLY SPRINKLERED

STRUCTURAL MEP / FP

DESIGN SPECIALTY

CARE BUILDING

718 Smyth Road, Manchester, NH 03104

608-315

Simpson Gumpertz & Heger 41 Seyon Street Waltham, MA 02453

T: 781.907.9000 sgh.com

BR+A

10 Guest Street, 4th

FLR

Boston, MA 02135

T: 617.254.0016 brplusa.com

CIVIL

Meridian Associates 500 Cummings Center Suite 5950 Beverly, MA 01915

T: 978.299.0447 meridianassoc.com 12/20/2023

129 South St, 2nd floor

ARCHITECT

SITE LAYOUT & MATERIALS PLAN

C-2.0

PROPOSED CONDITIONS LEGEND:

LIMIT OF WORK

PAD MOUNTED TRANSFORMER T

CONCRETE WALKWAY

INTERLOCKING BLOCK RETAINING WALL

BOLLARD

PROPOSED VERTICAL GRANITE CURB (VGC)

LAYOUT & MATERIALS NOTES:

1. ALL LINES AND DIMENSIONS ARE PARALLEL OR PERPENDICULAR TO THE LINES FROM WHICH THEY ARE

MEASURED UNLESS OTHERWISE INDICATED.

2. ALL ACCESSIBLE ROUTES, RAMPS, AND PARKING SPACES TO COMPLY WITH ADA AND VAMC REGULATIONS (TYP).

3. ALL CURB RADII TO BE R5' UNLESS OTHERWISE NOTED.

4. SEE ARCHITECTURAL DRAWINGS FOR BUILDING LAYOUT, DOOR PADS, EQUIPMENT PADS, STAIRWAYS, BUILDING

LIGHTING, ELECTRICAL INFORMATION AND ALL OTHER BUILDING APPURTENANCES.

5. DETECTABLE WARNING PANELS MAY BE PRECAST OR CAST IN PLACE OR OTHER SUITABLE MATERIAL PERMANENTLY APPLIED TO RAMP (SURFACE APPLIED SYSTEMS WILL NOT BE PERMITTED). DETECTABLE WARNING SURFACES SHALL CONTRAST VISUALLY WITH ADJACENT WALKING SURFACES EITHER LIGHT-ON-DARK, OR DARK-ON-LIGHT. DETECTABLE WARNING PANELS SHALL BE YELLOW. DETECTABLE WARNING PANELS ARE REQUIRED ON ALL PROPOSED WHEELCHAIR RAMPS AND ARE TO BE INSTALLED IN ACCORDANCE AS VAMC

STANDARD DETAIL.

6. CONTRACTOR SHALL REPORT SIGNIFICANT CONFLICTS TO THE OWNER OR HIS REPRESENTATIVE FOR RESOLUTION.

7. THE CONTRACTOR SHALL FURNISH AND SET ALL LINES AND GRADES REQUIRED AND PROTECT ALL PERMANENT BENCHMARKS OR MONUMENTS. DAMAGED MONUMENTS SHALL BE REPLACED BY A LICENSED SURVEYOR AT NO

COST TO THE OWNER.

8. CONTRACTOR TO PERFORM BENCHMARK FIELD LEVEL VERIFICATION AND COORDINATE LAYOUT CHECK PRIOR TO

CONSTRUCTION. CONTRACTOR TO CONTACT ENGINEER IF ANY DISCREPANCIES ARE FOUND.

9. WHERE ALL EXISTING CURBING OR PAVEMENT ABUT NEW CONSTRUCTION, THE EDGE OF THE EXISTING CURB OR PAVEMENT SHALL BE SAW CUT TO A CLEAN, SMOOTH EDGE. BLEND NEW PAVEMENT AND CURBS SMOOTHLY

INTO EXISTING BY MATCHING LINES, GRADES AND JOINTS.

10. RE-GRADE, LOAM AND SEED ALL DISTURBED AREAS UNLESS OTHERWISE INDICATED ON PLAN. LOAM

WITH TOPSOIL SPREAD TO A MINIMUM DEPTH OF (6) SIX INCHES.

December 20, 2023

CONSTUCT SPECIALTY

CARE BUILDING

N

ST

N-SD

N-S D

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N-SD

N-

SD

N-

SD

N-SD

N-SD

NSD

N-

SD

N-

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

WG

W

GSP

W

GSP

W G

W G

WG

W G

WG

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

474473

5 46

SD

SD

SD

SD

SD

SD

SD

A a b

D D

D

D

D

PROPOSED DESIGN SPECIALTY CARE BUILDING

FINISHED FLOOR ELEVATION = 467.5

PROPOSED

TRANSFORMER ON

CONCRETE PAD

WITH BOLLARDS

PROPOSED

INTERLOCKING BLOCK

RETAINING WALL

(TOP TO EXTEND 6" AFG)

467.5

465.8

467.5

466.5

MATCH EXISTING

GRADE 463.5

T

TW=469.5

BW=466.0

TW=469.0

BW=467.2466.5

466.5

467.0 467.0

467.0 467.0

467.5

466.3

LIMIT OF WORK

467.0

PROPOSED 8" HDPE ROOF

DRAIN LINE

L=24' S=0.054 FT/FTPDMH#1

RIM=465.7

PDMH#2

RIM=465.3

PROPOSED 12"

HDPE DRAIN LINE

L=8'

S=0.100 FT/FT

PROPOSED SUBSURFACE

INFILTRATION FACILITY (28

CULTEC RECHARGER 330XLHD

CHAMBERS OR APPROVED

EQUAL)

TW=469.5

BW=466.8

M

IN

LIMIT OF WORK

PDMH#3

RIM=465.3

PROPOSED 6"

OBSERVATION

PORT (TYP)

MATCH

EXISTING

GRADE

467.42

PROPOSED 4" PERF.

PVC UNDERDRAIN

L=120' S=0.5%

PROPOSED

UNDERDRAIN

PROPOSED

TRANSFORMER ON

CONCRETE PAD

T

LIMIT OF

WORK

PLVMH-5

RIM=469±

PHVMH-5

RIM=468±

467.25

467.25

466.5

466.3

CAP END

OF PIPE

INV=467.1

OPEN PIPE

INV=466.5

TC:ME+0.5'

BC:ME

TC:ME+0.5'

BC:ME

TC:ME+0.5'

BC:ME

TC:ME+0.5'

BC:ME

SCALE: 1" = 20'

60'40'20'20' 010'

Project Number

Building Number

Drawing Number

Project Title

Location

Issue Date Checked Drawn

Drawing Title

Approved:

VA FORM 08 - 6231

A

Office of Construction and Facilities Management

U.S. Department of Veterans Affairs

B

C

D

E

F

A

B

C

D

E

F

21 4 5 6 7 8 9 10

Phase

STAMPCONSULTANT

321 4 5 6 7 8 9 10

DSK DSKRevisions: Date:

Boston, MA 02210

T: 617.772.0260 F: 617.772.0261 www.e4harchitecture.com

FINAL FOR

CONSTRUCTION

FULLY SPRINKLERED

STRUCTURAL MEP / FP

DESIGN SPECIALTY

CARE BUILDING

718 Smyth Road, Manchester, NH 03104

608-315

Simpson Gumpertz & Heger 41 Seyon Street Waltham, MA 02453

T: 781.907.9000 sgh.com

BR+A

10 Guest Street, 4th

FLR

Boston, MA 02135

T: 617.254.0016 brplusa.com

CIVIL

Meridian Associates 500 Cummings Center Suite 5950 Beverly, MA 01915

T: 978.299.0447 meridianassoc.com 12/20/2023

129 South St, 2nd floor

ARCHITECT

GRADING PLAN

C-3.0

PROPOSED CONDITIONS LEGEND:

CONTOUR

LIMIT OF WORK

DRAIN MANHOLE DMH

SPOT ELEVATION

INVERT ELEVATION INV.

TYPICAL TYP.

VERIFY IN FIELD VIF

TOP OF CURB TC

BOTTOM OF CURB BC

TOP OF WALL TW

BOTTOM OF WALL BW

ELECTRIC MANHOLE EMH

PAD MOUNTED TRANSFORMER T

CONCRETE WALKWAY

INTERLOCKING BLOCK RETAINING WALL

BOLLARD

GRADING AND DRAINAGE NOTES:

1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING THAT THE PROPOSED IMPROVEMENTS SHOWN ON THE

PLANS DO NOT CONFLICT WITH ANY KNOWN EXISTING OR OTHER PROPOSED IMPROVEMENTS. IF CONFLICTS ARE DISCOVERED, THE CONTRACTOR SHALL NOTIFY THE OWNER AND THE ENGINEER PRIOR TO INSTALLATION OF ANY PORTION OF THE SITE WORK WHICH WOULD BE AFFECTED. NO FIELD ADJUSTMENTS IN THE LOCATION OF SITE

ELEMENTS SHALL BE MADE WITHOUT THE ENGINEER'S APPROVALS.

2. ALL WORK PERFORMED AND ALL MATERIALS FURNISHED SHALL CONFORM WITH THE LINES AND GRADES ON THE

PLANS AND SITE WORK SPECIFICATIONS.

3. AT ALL LOCATIONS WHERE EXISTING CURBING OR PAVEMENT ABUT NEW CONSTRUCTION, THE EDGE OF THE EXISTING CURB OR PAVEMENT SHALL BE SAW CUT TO A CLEAN, SMOOTH EDGE. BLEND NEW PAVEMENT AND

CURBS SMOOTHLY INTO EXISTING BY MATCHING LINES, GRADES AND JOINTS.

4. ALL UTILITY COVERS, GRATES, ETC. SHALL BE ADJUSTED TO BE FLUSH WITH THE SURROUNDING SURFACE OR PAVEMENT FINISH GRADE. RIM ELEVATIONS OF STRUCTURES AND MANHOLES ARE APPROXIMATE. FINAL

ELEVATIONS ARE TO BE SET FLUSH AND CONSISTENT WITH THE GRADING PLANS.

5. THE CONTRACTOR SHALL MAKE ALL ARRANGEMENTS FOR THE ALTERATION OF PRIVATE UTILITIES BY THE UTILITY

COMPANIES, AS REQUIRED.

6. WHERE AN EXISTING UTILITY IS FOUND TO CONFLICT WITH THE PROPOSED WORK, THE LOCATION, ELEVATION AND SIZE OF THE UTILITY SHALL BE ACCURATELY DETERMINED WITHOUT DELAY BY THE CONTRACTOR AND THE

INFORMATION FURNISHED TO THE ENGINEER FOR RESOLUTION.

7. THE CONTRACTOR SHALL PROTECT ALL UNDERGROUND TEL/DATA DUCT BANKS, ELECTRICAL DUCT BANKS, DRAINAGE, SEWER AND UTILITY FACILITIES FROM EXCESSIVE VEHICULAR LOADS DURING CONSTRUCTION. ANY DAMAGE TO THESE FACILITIES RESULTING FROM CONSTRUCTION LOADS WILL BE RESTORED TO ORIGINAL

CONDITION BY THE CONTRACTOR AT NO ADDITIONAL EXPENSE TO THE OWNER.

8. DURING CONSTRUCTION OPERATIONS, THE CONTRACTOR SHALL PROTECT EXISTING UTILITIES BY PROVIDING

TEMPORARY SUPPORTS OR SHEETING AS REQUIRED AT NO ADDITIONAL COST TO THE OWNER.

9. EXCAVATION REQUIRED WITHIN THE PROXIMITY OF EXISTING UTILITY LINES SHALL BE DONE BY HAND.

CONTRACTOR SHALL REPAIR ANY DAMAGE TO EXISTING UTILITY LINES OR STRUCTURES INCURRED DURING

CONSTRUCTION OPERATIONS AT NO COST TO THE OWNER.

10. PITCH EVENLY BETWEEN SPOT GRADES. ALL PAVED AREAS MUST PITCH TO DRAIN AT A MIN. OF 1/8” PER FOOT

UNLESS SPECIFIED.

11. THE PROPOSED WALKWAYS SHALL HAVE A MAXIMUM CROSS SLOPE OF 2% AND RUNNING SLOPE OF 3% AS

SHOWN ON CONSTRUCTION DETAILS AND GRADING PLAN.

12. THE CONTRACTOR IS RESPONSIBLE FOR REMOVAL AND DISPOSAL OF ALL ROCK AND BOULDERS UNCOVERED

DURING UTILITY INSTALLATION. REFER TO EARTHWORK SPECIFICATION.

13. THE CONTRACTOR IS RESPONSIBLE FOR ALL EQUIPMENT, MATERIAL, AND LABOR REQUIRED TO CLEAN OUT

EXISTING CATCH BASINS AND PIPING PRIOR TO COMMENCING WORK.

467.0

LEDGE REMOVAL QUANTITIES:

1. CONTRACTOR IS TO REFER TO SECTION 31 20 00 - 'EARTH MOVING' OF THE CONSTRUCTION SPECIFICATIONS FOR

ADDITIONAL EARTH REMOVAL REQUIREMENTS. ADDITIONALLY, THE CONTRACTOR IS TO CARRY THE FOLLOWING

VOLUMES OF LEDGE REMOVAL AS A PART OF THE CONTRACT BID:

1.1. THE CONTRACTOR TO CARRY ALLOWANCE FOR 35 CU YD OF LEDGE/ROCK REMOVAL FOR THE STORMWATER MANAGEMENT SYSTEM AND SHALL ALSO PROVIDE A UNIT COST FOR ADDITIONAL LEDGE REMOVAL.

1.2. CONTRACTOR TO CARRY ALLOWANCE FOR 35 CU YD OF LEDGE/ROCK REMOVAL FOR THE SANITARY SEWER

SYSTEM AND SHALL ALSO PROVIDE A UNIT COST FOR ADDITIONAL LEDGE REMOVAL.

1.3. CONTRACTOR TO CARRY ALLOWANCE FOR 60 CU YD OF LEDGE/ROCK REMOVAL FOR THE DOMESTIC / FIRE

WATER SYSTEM AND SHALL ALSO PROVIDE A UNIT COST FOR ADDITIONAL LEDGE REMOVAL.

1.4. CONTRACTOR TO CARRY ALLOWANCE FOR 35 CU YD OF LEDGE/ROCK REMOVAL FOR THE STEAM SYSTEM

AND ALSO PROVIDE A UNIT COST FOR ADDITIONAL LEDGE REMOVAL.

1.5. CONTRACTOR TO CARRY ALLOWANCE FOR 60 CU YD OF LEDGE/ROCK REMOVAL FOR THE ELECTRICAL, TELEPHONE AND DATA SYSTEM AND SHALL ALSO PROVIDE A UNIT COST FOR ADDITIONAL LEDGE REMOVAL.

December 20, 2023

CONSTUCT SPECIALTY

CARE BUILDING

G

AS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

GAS

G

AS

G

AS

GAS

GAS

GAS

GAS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

G

AS

GAS

GAS

GAS

NST

NST

NST

N

ST

PHASE TWO

6" ST

4" CND

MP101

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

SS

NW

NW

NW

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N

-SD

N-SD

N-

SD

N-

SD

N-SD

N-SD

NSD

N-

SD

N-

SD

SD

SD

SDSDSD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD SD

SD

SD

SD

SD

SD SD

WG

WG

W

GSP

W

GSP

W G

WG

W G

W

GWG

W G

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

WG

W W

W W

W W

W

WWWWWWWWWWWWW

W

W W

W W

W

WWWWWWWWWWWWW

W

W W

W W

W

WWW

W W

W

W

W

W

W

W

W W

N W

NW

NWNW

NW

N W

NW

NW

U G

C

UGC

UGC

UGC

UGC

UGC

UGC

U G

C

UG

C

UGC

GG

GG

GGSP

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

E

UGEUGEUGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

U G

E

UG

E

UG

E

UG

E

UG

E

UG

E

UG

E

U G

E U

G E

UGE

UGEUGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE UGE UGE

UG

E

UG

E

UG

E

UG

E

UGE

UGE

UGE

U G

E U

G E

U G

E U

G E

U G

E U

G E

UGE

UGE

UGE

UGE

UGE

U G

E

U G

E

U G

E

U G

E

UGE

UGE

UGE

UGE

UGE

E & FA Q

L-B

2-4" E Q

L-B

2-4" E QL-B

2- 4"

E Q

L- B

2-4" PVC E QL-B

1"± E

Q L-B

1"± E QL-B

2-3" (R) E QL-B

5- 4"

-1 " E

/T /F

A Q

L- B

4" E

QL-B

2-3" E QL-B

2-2" E QL-B

EO

I

E Q

L- B

E QL-B

E QL-B

2"

IP

E Q

L- B

4-4" PVC E QL-B

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

SD

S

S

S

S

S

S

S

S

S

S

S S S S S S SSS

SS

SS

SS

SS

SS

W

W W W

W

W W W

UGE

UGE

UGEUGEUGEUGE

UGE

UGEUGEUGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE

UGE UGE

UGE

UGE

UGE

UGE

UGE

SD

SD

SD

SD

SD

SD

SD E

a b

E E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E E E E E E E E E

E

E

E

E

E

E

E

E

E

E

E

S S

S

D D

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E

E E

E E

E E

E E

E

E

E

E

E E E E E E

D

W W W W W W

W

W

W W

W W

W W

W W

W W W W W

D

D

PROPOSED DESIGN SPECIALTY CARE BUILDING

FINISHED FLOOR ELEVATION = 467.5

PROPOSED 8" SDR 35

PVC SEWER SERVICE

L=65'

S=0.069 FT/FT

PROVIDE OUTSIDE DROP

CONNECTION TO EXISTING

SEWER MANHOLE. CORE

MANHOLE AND INSTALL RUBBER

BOOT CONNECTION. REBUILD

EXISTING TROUGH.

INV.=458.0

INV.=462.5

PROPOSED 8" DI

WATER LINE

PROPOSED 4" DOMESTIC

WATER SERVICE

PROPOSED 6" DI

FIRE WATER SERVICE

PROPOSED

TRANSFORMER ON

CONCRETE PAD

WITH BOLLARDS

PROPOSED

INTERLOCKING BLOCK

RETAINING WALL

(TOP TO EXTEND 6" AFG)

T

PROPOSED ELECTRIC

MANHOLE (REFER TO

ELECTRICAL PLANS

FOR DETAILS)

PROPOSED

ELECTRIC SERVICE

LIMIT OF WORK

PROPOSED 6" DI

WATER LINE

PROPOSED FIRE

HYDRANT

PROPOSED 8" HDPE ROOF

DRAIN LINE

L=24' S=0.054 FT/FT

INV.=463.0

PDMH#1

RIM=465.7

PDMH#2

RIM=465.3

PROPOSED 12"

HDPE DRAIN LINE

L=8'

S=0.100 FT/FT

INVa=461.7 INVb=460.5 INVc=460.5 a b c a b

INVa=462.2 INVb=462.1

INVa=461.3 INVb=456.9 INVc=456.9 ab c

PROPOSED SUBSURFACE

INFILTRATION FACILITY (28

CULTEC RECHARGER 330XLHD

CHAMBERS OR APPROVED

EQUAL)

PROPOSED 8" DI WATER

LINE CONNECTION POINT

PROPO…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .