Attachment 4 - VAMC_MANCHESTER_A5-2.1 - 608-315.pdf
PDF 213 KB Posted
- Solicitation number
- 36C77625B0024
About this file
This document is a detailed Door Schedule for a Design Specialty Care Building project for the U.S. Department of Veterans Affairs located at 718 Smyth Rd, Manchester, NH. The schedule comprehensively lists 57 doors across three levels (Basement, First Floor, and Roof Deck), specifying door numbers, room names, door sizes, materials, glazing types, frame types, and hardware specifications. Doors range in width from 3'-0" to 5'-0" and height is consistently 7'-0", with various configurations including full glass, narrow light, and sidelights. The doors serve diverse spaces such as exam rooms, offices, corridors, waiting areas, staff facilities, and technical rooms, with specific fire rating and hardware requirements noted for each door. The document was issued on 12/20/2023 and marked as "Final for Construction" with recent revisions on 08/14/2025 and 08/21/2025 addressing bid questions and laminated glazing specifications.
View the file
Other files
Show all 44
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
H E
IG
H
T
2" WIDTH 2"
H E
IG
H
T
2" WIDTH 2"
SINGLE OR DOUBLE DOORS1 SINGLE OR DOUBLE DOORS
[EXTERIOR]
2' - 0" 2" WIDTH 2"
SINGLE DOOR WITH SIDELIGHT4
H E
IG
H
T
2" WIDTH 2"
DOUBLE SWING
[TOILETS]
6" 6'
-6
2" 1'
-0
2"
2" 1'-8" 2" 3'-0" 2"
4"
CLINIC AND WAITING ROOM OPTICAL SLIDING BARN DOOR6
P A
N E
L H
E
IG
H T
2"
SEE SCHED
TOTAL PNL WIDTH
2"
MIN.
3' - 0" CLEAR
A5-2.1
A5-2.13
A5-2.1
A5-2.1
A5-2.1
A5-2.1
A2-2.3
A2-2.3
A2-2.3
A2-2.3
A2-2.3
A2-2.3
A2-2.3
A2-2.3
A3-2.1
GL-1GL-1
GL-1
GL-1
WIDTH
H E
IG
H
T
ALL PATIENT CARE SPACES, TOILET
ROOMS, STORAGE ROOMS AND BASE
BUILDING ROOMS
F
WIDTH
H E
IG
H
T
NARROW LIGHT - SMALLNL1
6" 6"
WIDTH
H E
IG
H
T
OFFICES, WORK STATIONS, AND OPTICALNL2
6" 5"
WIDTH
H E
IG
H
T
FULL GLASSFG
6"
6"
1'
0"
GL-1 GL-1GL-1
TYPICAL OF ALL EXTERIOR GLAZING:
INSULATED GLASS UNITS - INNER LAYER TO BE LAMINATED GLASS CLAD POLYCARBONATE SAFETY GLASS
SEALANT AT PERIMETER
BOTH SIDES
HOLLOW METAL FRAME
AS SCHEDULEDJAMB ANCHORS PER
MANUFACTURER'S
RECOMMENDATION
STUDS, RUNNER, AND
SUPPORT
EMERGENCY
RELEASE
HARDWARE
V A
R
IE
S
S E
E P
A R
T
IT
IO
N
T Y
P E
V A
R
IE
S
FRAME ANCHORS -
MINIMUM 3 PER JAMB
STEEL FRAME
GWB PARTITION - SEE
FLOOR PLANS FOR
TYPES
D E
P
TH
FR
A
M E
1/ 2"
DOOR - SEE SCHEDULE
2"
1/ 2"
1/8" THICK CONT STL REINF
CHANNEL WELDED TO FRAME HEAD
AT OPENINGS LARGER THAN 4'-0"
INSTALL CRIPPLE STUDS IN CENTER
ABOVE DOOR OPENING AT 16" OC
STUD RUNNER HEADER 20 GA MIN
1/2"
GWB PARTITION - SEE FLOOR
PLANS FOR TYPES
STEEL FRAME2"
NOTE:
AT EACH END OF STUD HEADER
PROVIDE CRIPPLE STUD ANCHORED
TO JAMB STUDS
DEPTH
FRAME
1/2"
EPDM GASKET
EPDM GASKET
SILICONE LIP
SEAL
2"
1"1"
MIN. 16GA STUD FRAMING
#14x2 HWH TEK SCREW
6" FROM EACH END OF
JAMPS AND AT CENTER
(FRAME OPENING)
ALUMINUM FRAME
2X6 BLOCKING
#14x2 1/2" HWH
TEK SCREWS @
12"O.C.
EPDM
GASKET
MIN. 16GA STUD
FRAMING
2 7/8"
J80 RUNNING
GEAR
HANDERS W/
SCREWS
HIGH DENSITY
PILE
ALUMINUM FRAME
ALUMINUM
VALANCE
LEGEND:
ALM ALUMINUM
HM HOLLOW METAL
WD WOOD
DOOR LEGEND
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ARCHITECT STAMPCONSULTANT
321 4 5 6 7 8 9 10
129 South St, 2nd floor Boston, MA 02210
T: 617.772.0260 F: 617.772.0261 www.e4harchitecture.com
FINAL FOR
CONSTRUCTION
FULLY SPRINKLERED
STRUCTURAL MEP / FP
Simpson Gumpertz & Heger 480 Totten Pond Road Waltham, MA 02451
T: 781.907.9000 sgh.com
BR+A
10 Guest Street, 4th FLR Boston, MA 02135
T: 617.254.0016 brplusa.com
CIVIL
Meridian Associates, Inc.
500 Cummings Center, Suite 5950 Beverly, MA 01915
T: 978.299.0447 meridianassoc.com
A u to d e s k D o c s /V
A M
C M a n c h e s te r S p e c ia lt y C lin ic
/V A
M C
M
A N
C H
E S
T E
R S
P E
C C
L
IN
IC
R
.r v t
/2
/2
:4
:5
P
M
A5-2.1
DOOR SCHEDULE DESIGN SPECIALTY
CARE BUILDING
718 Smyth Rd, Manchester, NH 03104
608-315
12/20/2023
DOOR SCHEDULE
DOOR # ROOM NAME
DOOR SIZE
Glazing Type
FRAME
HARDWARE FIRE RATING REMARKS
DOOR
TYPE MATERIAL WIDTH HEIGHT
FRAME
TYPE
FRAME
MATERIAL
Basement Landing
SWA157 BASEMENT STAIRS F WD 3' - 0" 7' - 0" 1 HM 4
First Floor
SW198 EXISTING CORR. NEW DOOR
A
NL1 WD 3' - 6" 7' - 0" GL-1 1 HM 4a NEW DOOR IN EXISTING CORRIDOR
SW199 EXISTING CORR. NEW DOOR
B
NL1 WD 3' - 6" 7' - 0" GL-1 1 HM 4a NEW DOOR IN EXISTING CORRIDOR
SWA100A VESTIBULE F HM 3' - 0" 7' - 0" 2 HM 6
SWA100B VESTIBULE F WD 3' - 0" 7' - 0" 4 HM 13
SWA101 WAITING FG WD 3' - 6" 7' - 0" GL-1 3 HM 14
SWA102 STAIRS F WD 3' - 0" 7' - 0" 1 HM 4 60 MIN 45 MIN DOOR, CLOSER REQ'D
SWA103 TOIL F WD 3' - 0" 7' - 0" 5 HM 7
SWA104 TOIL F WD 3' - 0" 7' - 0" 5 HM 7
SWA105 ELEC F WD 3' - 0" 7' - 0" 1 HM 5 CLOSER REQ'D
SWA105A ELEC F WD 5' - 0" 7' - 0" 1 HM 3a CLOSER REQ'D
SWA107 EQUIPMENT F WD 3' - 0" 7' - 0" 1 HM 3
SWA108 PROGRAMMING FITTING
ROOM
F WD 3' - 6" 7' - 0" 1 HM 2
SWA109 PROGRAMMING FITTING
ROOM
F WD 3' - 6" 7' - 0" 1 HM 2
SWA110 PROGRAMMING FITTING
ROOM
F WD 3' - 6" 7' - 0" 1 HM 2
SWA111 PROGRAMMING FITTING
ROOM
F WD 3' - 6" 7' - 0" 1 HM 2
SWA112 WORK STATIONS (4) NL2 WD 3' - 0" 7' - 0" GL-1 1 HM 2
SWA113 AUDIO SERVICE CHIEF NL2 WD 3' - 0" 7' - 0" GL-1 1 HM 1
SWA117 AUDIO TECH F WD 3' - 6" 7' - 0" 1 HM 2
SWA118 CLEAN SUPPLY F WD 3' - 0" 7' - 0" 1 HM 4
SWA119 CERUMEN MANAGMENT F WD 3' - 6" 7' - 0" 1 HM 2
SWA120 PROGRAMMING AND FITTING
ROOM
F WD 3' - 6" 7' - 0" 1 HM 2
SWA121 TR F WD 3' - 0" 7' - 0" 1 HM 15
SWA122 WATER SERVICE F WD 3' - 0" 7' - 0" 1 HM 4
SWA123 H.A.C F WD 3' - 0" 7' - 0" 1 HM 3
SWA124 VESTIBULOGRAPHY /
TELEHEALTH
F WD 3' - 6" 7' - 0" 1 HM 2
SWA125 PROCEDURE F WD 3' - 6" 7' - 0" 1 HM 2
SWA126 HEARING AID PROCESSING F WD 3' - 0" 7' - 0" 1 HM 2
SWA127 HEARING AID MODIFICATION F WD 3' - 6" 7' - 0" 1 HM 2
SWA128 OPTICAL NL2 3' - 6" 7' - 0" GL-1 6 8 REFER TO DOOR HARDWARE SPEC 08 71 00
SWA129 EXAM 1 LASER & PROCEDURE F WD 3' - 6" 7' - 0" 1 HM 3
SWA130 EXAM 2 LOW VISION EXAM F WD 3' - 6" 7' - 0" 1 HM 1
SWA131 EXAM 3 F WD 3' - 6" 7' - 0" 1 HM 1
SWA132 EXAM 4 F WD 3' - 6" 7' - 0" 1 HM 1
SWA133 EXAM 5 F WD 3' - 6" 7' - 0" 1 HM 1
SWA134 EXAM 6 F WD 3' - 6" 7' - 0" 1 HM 1
SWA135 SOILED F WD 3' - 0" 7' - 0" 1 HM 3
SWA136 STAFF TOILET F WD 3' - 0" 7' - 0" 5 HM 7
SWA137 STAFF TOILET F WD 3' - 0" 7' - 0" 5 HM 7
SWA139 LOUNGE F WD 3' - 0" 7' - 0" 1 HM 4
SWA140 EXAM 7 F WD 3' - 6" 7' - 0" 1 HM 1
SWA141 EXAM 8 F WD 3' - 6" 7' - 0" 1 HM 1
SWA142 EXAM 9 F WD 3' - 6" 7' - 0" 1 HM 1
SWA143 EXAM 10 F WD 3' - 6" 7' - 0" 1 HM 1
SWA144 EXAM 11 BARIATRIC F WD 3' - 6" 7' - 0" 1 HM 1
SWA145 RECEPTION NL2 WD 3' - 0" 7' - 0" GL-1 1 HM 2
SWA146 CLEAN F WD 3' - 0" 7' - 0" 1 HM 4
SWA147 STOR F WD 3' - 0" 7' - 0" 1 HM 4
SWA148A IMAGING F WD 3' - 6" 7' - 0" 1 HM 2
SWA148B IMAGING F WD 3' - 6" 7' - 0" 1 HM 2
SWA149 EXAM 12 PRETEST F WD 3' - 6" 7' - 0" 1 HM 2
SWA150 OPTOMETRY SERVICE CHIEF NL2 WD 3' - 0" 7' - 0" GL-1 1 HM 1
SWA151 WORK STATIONS (4) NL2 WD 3' - 0" 7' - 0" GL-1 1 HM 2
SWA152 OFFICE NL2 WD 3' - 0" 7' - 0" GL-1 1 HM 2
SWA153 HEALTH TECHS WKSTA NL2 WD 3' - 0" 7' - 0" GL-1 1 HM 2
SWA154 CONFERENCE ROOM F WD 3' - 0" 7' - 0" 4 HM 4
SWA155 VISUAL FIELDS F WD 3' - 6" 7' - 0" 1 HM 2
SWA160A WAITING F WD 3' - 6" 7' - 0" 3 HM 4a
SWA160B CORRIDOR FG 3' - 2" 7' - 0" GL-1 C 3'-0" ALUM DOOR , SEE STORFRONT SCHEDULE
SWA160D CORRIDOR F WD 3' - 6" 7' - 0" 3 HM 4a
SWA160F CORRIDOR FG 3' - 0" 7' - 0" GL-1 C 3'-0" ALUM DOOR , SEE STORFRONT SCHEDULE
SWA161A CORRIDOR NL1 WD 3' - 6" 7' - 0" GL-1 1 HM 4.1
SWA161B CORRIDOR NL1 WD 3' - 0" 7' - 0" GL-1 1 HM 12
Roof Deck
SWA200 PENTHOUSE F HM 3' - 0" 7' - 0" 1 HM 9
SWA200A PENTHOUSE ROOF ACCESS A F HM 3' - 0" 7' - 0" 2 HM 10
SWA200B PENTHOUSE ROOF ACCESS B F HM 3' - 0" 7' - 0" 2 HM 10
SWA201 PENHOUSE ELEC F HM 3' - 0" 7' - 0" 1 HM 5
SCALE: 3/8" = 1'-0"2
FRAME TYPE
SCALE: 3/8" = 1'-0"1
DOOR TYPE
3" = 1'-0"
EMERGENCY RELEASE JAMB
3" = 1'-0"
JAMB DETAIL AT HOLLOW METAL DOOR FRAME
3" = 1'-0"
HEAD DETAIL AT HOLLOW METAL DOOR FRAME
3" = 1'-0"
BARN DOOR JAMB DETAIL
3" = 1'-0"
BARN DOOR HEAD DETAIL
Revisions: Date:
Revised per Bid Questions 08/14/2025
Revision for Laminated Glazing 08/21/2025
| Sheets |
| A5-2.1 - DOOR SCHEDULE |
File details come from the government source that posted it. Updated .