Atch 2 - 087100 Door Hardware 2025-07-31.pdf

PDF 1 MB Posted

Attached to
Y1DB--Construct Specialty Care Building - Manchester Minor Project 608-315
Solicitation number
36C77625B0024
Issued by

About this file

This document is a detailed Door Hardware specification for the VA Medical Center's Design Specialty Care Building project in Manchester, NH, dated July 31, 2025. The specification provides comprehensive technical requirements for door hardware across multiple hardware sets (HW-1 through HW-15), covering various door types and functions including office, passage, storeroom, and specialized electronic access configurations.

Key hardware components specified include hinges from McKinney, locksets from Sargent (8200-CENF Series), exit devices, closers from Norton, stops, gasketing from Pemko, and ADA power operators from Dorma. The specification includes detailed requirements for finishes (predominantly US32D), mounting positions, installation guidelines, and integration with security systems. Multiple hardware sets incorporate conductor hinges, electric locksets, electric strikes, kick plates, and additional accessories like coat hooks, with specific voltage requirements (24V/120V) and coordination with security systems noted for electronically controlled hardware.

View the file

Other files

File Type Posted
36C77625B0024 0008.docx DOCX document
Attachment 5 - 084413 - Glazed Aluminum Curtain Wall.pdf PDF
Attachment 4 - VAMC_MANCHESTER_A5-2.1 - 608-315.pdf PDF
Attachment 1 - Virtual Bid Opening Updated - Manchester.pdf PDF
Attachment 2 - Tech Qs - Manchester 618-315 2025-08-22 responses.docx DOCX document
36C77625B0024 0008.docx DOCX document
Attachment 3 - VAMC_MANCHESTER_A2-2.3 - 608-315.pdf PDF
S06 - Atch 1 - Virtual Bid Opening Updated 8.19.25 - Manchester.pdf PDF
36C77625B0024 0007.docx DOCX document
S06 - Atch 1 - Tech Qs - Manchester 618-315 NEW 8.13.2025.docx DOCX document
S06 - Atch 2 - Panel DP nameplate - 608-315.jpg JPG image
36C77625B0024 0006.docx DOCX document
Atch 1 - Virtual Bid Opening UPDATED - Manchester NH 608-315.pdf PDF
36C77625B0024 0005.docx DOCX document
S06 - Atch 4 - Bid Addendum Bldg 1 Basement Floor Plan.pdf PDF
S06 - Atch 1 - Tech Qs - Manchester 618-315 8.7.2025.docx DOCX document
36C77625B0024 0004.docx DOCX document
S06 - Atch 2 - Q60 Response Select Drawings from Existing Building Construction.pdf PDF
S06 - Atch 6 - 122400 - Window Shades.pdf PDF
S06 - Atch 5 - Bid Addendum Bldg 1 First Floor Plan.pdf PDF
S06 - Atch 3 - Bid Addendum 1 Drawing Corrections.pdf PDF
36C77625B0024 0003.docx DOCX document
Atch 1 - Tech Qs - Manchester 608-315 07252025.docx DOCX document
Atch 6 - Bid Addendum Bldg 1 First Floor Plan.pdf PDF
Atch 2 - Site Visit Agenda - Manchester NH 608-315.pdf PDF
Atch 8 - 122400 - Window Shades.pdf PDF
Atch 3 - Site Visit Sign-In Sheet - Manchester NH 608-315.pdf PDF
Atch 4 - Virtual Bid Opening Information - Manchester NH 608-315.pdf PDF
36C77625B0024 0002.docx DOCX document
Atch 5 - Bid Addendum Bldg 1 Basement Floor Plan.pdf PDF
Atch 1 - Tech Qs - Manchester 608-315 FINAL.docx DOCX document
Atch 7 - Bid Addendum Drawing Corrections.pdf PDF
Atch 1 - Specs V2 of 2 - Manchester - 608-315 Rev 2025-06-24.pdf PDF
36C77625B0024 0001.docx DOCX document
Attachment 9 - Brand Name JA - Manchester Redacted - 608-315.pdf PDF
Attachment 3 - Site Visit Instructions - Manchester - 608-315.pdf PDF
Attachment 1 - Limitations on Subcontracting - Construction - 608-315.docx DOCX document
Attachment 5 - Specifications V2 of 2 - Manchester - 608-315.pdf PDF
36C77625B0024_1.docx DOCX document
Attachment 6 - Drawings Part 1 of 3 - Manchester - 608-315.pdf PDF
Attachment 8 - Drawings Part 3 of 3 - Manchester - 608-315.pdf PDF
Attachment 4 - Specifications V1 of 2 - Manchester - 608-315.pdf PDF
Attachment 2 - DBA Wage Rates - Manchester - 608-315 - NH20250021 03.14.2025.pdf PDF
Attachment 7 - Drawings Part 2 of 3 - Manchester - 608-315.pdf PDF
Show all 44

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

VA MEDICAL CENTER July 31, 2025 VA Project No. 608-315 DESIGN SPECIALTY CARE BUILDING

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 1 of 12

SECTION 08 71 00

DOOR HARDWARE

PART 1 – GENERAL

1.1 SUMMARY

A. The work of this section includes the furnishing of door hardware as shown on the Drawings and as herein specified for the proper operation of wood and hollow metal doors which, without limiting the generality thereof includes:

1. Furnishing all required templates and schedules.

2. Delivery of door hardware under this Section to the Contractor for installation.

B. Coordinate work with related trades.

1.2 RELATED SECTIONS

A. ROUGH CARPENTRY: Installation of Door Hardware.

B. WOOD DOORS

C. HOLLOW METAL FRAMES

D. ELECTRICAL

1.3 REFERENCES

A. Comply with applicable requirements of the following standards. Where these standards conflict with other specified requirements, the most restrictive requirements shall govern.

1. Americans with Disabilities Act (ADA):

Providing Accessibility and Usability for Physically Handicapped People.

2. Door and Hardware Institute (DHI):

Ref. 1 Recommended Locations for Builders Hardware.

1.4 SUBMITTALS:

A. Schedules: Submit a complete Electronic Hardware Schedule, in DHI vertical format.

Furnish through the General Contractor for approval by the Architect/Specifier. The Schedule shall list the Specification Hardware Set number next to the Schedule Heading Number and shall include a Door Index listing doors in numerical order with Schedule Heading Numbers.

B. Catalog Cuts: Include with the Schedule two sets of catalogue cuts, together with product data sheets, of all hardware items.

C. Catalog Cuts: Include with the Schedule two sets of catalogue cuts, together with product data sheets, of all hardware items.

D. Provide Bill of Materials index consisting of all hardware, manufacturers

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 2 of 12 and quantities of submitted items.

E. Templates: All required templates shall be furnished in accordance with the schedule.

Furnish templates to the door and frame manufacturer sufficiently in advance so as not to delay progress of the work. However, no templates shall be issued or materials ordered until the schedule has been approved.

F. Samples: A sample of each item of hardware the successful bidder proposes to furnish shall be submitted for approval not later than ten (10) days after being requested.

After review, samples shall be returned to the Supplier.

G. Shop Drawings: Details of electrified door hardware, indicating the following:

1. Wiring Diagrams: Detail wiring for power, signal, and control systems and differentiate between manufacturer-installed and field-installed wiring.

Include the following:

a. System schematic.

b. Point-to-point wiring diagram.

c. Riser diagram.

d. Elevation of each door.

2. Detail interface between electrified door hardware and fire alarm access control and building control and security systems.

1.5 PACKING AND MARKING

A. All hardware shall be delivered to the site in packages which are legibly marked with labels indicating the manufacturers' numbers, types and sizes, and with the Hardware Schedule reference number.

B. Each hardware item shall be wrapped together with all screws, bolts, and fastenings necessary for its proper installation.

1.6 DELIVERY AND STORAGE

A. The Contractor shall receive, check against invoices, and store all hardware at the job.

B. Delivery of hardware to the job shall be made in accordance with the Contractor's instructions.

C. The Contractor shall furnish the supplier of the hardware with receipts for all hardware received.

D. The Contractor shall provide adequate locked storage space with shelving, and shall be responsible for all items of hardware after receipt from the supplier. He shall replace all lost or damaged hardware at his own expense.

1.7 KEYING

A. All Locks and Cylinders shall be furnished with Best 6-Pin “F” Keyway Uncombinated Cores for permanent keying to be performed by VA Lockshop. Furnish (200) Key Blanks.

B. Furnish temporary Construction Cylinders as required by the GC for use during construction. All Construction shall be returned to the Supplier upon substantial completion of the project (non-returned Cores shall be subject to invoicing).

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 3 of 12

1.8 SPECIAL REQUIREMENTS

A. Hardware Supplier shall determine conditions and materials of all doors and frames for proper application of hardware.

B. Hardware Supplier shall be responsible for the accuracy of the quantities, sizes, finish and proper hardware to be furnished, whether specifically listed or not, and shall be responsible for determining all details, such as and of doors, bevel of locks, etc.

C. All lever trim for door locks to hazardous areas such as Mechanical, Electrical, Elevator Machine Rooms, etc., shall have a tactile surface to comply with requirements of the Authority Having Jurisdiction.

D. Tools for Maintenance: All special tools packed with hardware items shall be saved and turned over to the Owner upon completion of the Work.

E. Lock fronts, flush bolt faces, and strikes shall be beveled in accordance with manufacturer's standards.

F. Furnish strikes as required by details.

G. Handing of doors shall be verified by this supplier.

H. Hardware not specifically listed for a particular opening shall be the same as hardware scheduled for similar openings.

I. All electrified hardware items are to be interfaced with the Security and/or Fire Alarm System.

AC = Access Control Interface

CR = Card Reader

DC = Door Contact

PS = Power Supply

PART 2 - PRODUCTS

2.1 QUALITY ASSURANCE

A. Hardware shall be furnished as specified herein.

B. All hardware shall be entirely free from imperfection in manufacture and finish. It is the responsibility of the Hardware Supplier to follow the manufacturers' catalogue requirements for the proper size and weight of hardware and fastenings, and the proper function of hardware in each case. All door sizes are to be noted on the Door Schedule and all hardware shall be in strict accordance with requirements of height, width, and thickness.

C. The numbers used below to set a standard of quality for the major products for this project are taken from the catalogs of those manufacturers whose names appear in parentheses. Equivalent products of the other manufacturers listed are acceptable provided the products are equal to the items specified in quality, weight, design and function, and approved by the Architect. Where only one manufacturer is listed, no substitutions shall be accepted.

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 4 of 12

Item Manufacturers

Butts (McKinney) Hager, Stanley Keying (SFIC) Locksets (Sargent) Marks, Schlage Exit Devices (Sargent) Detex, Von Duprin Closers (Norton) LCN, Town Steel Stops (Rockwood), Burns, Hager Gasketing (Pemko) NGP, Reese

ADA Power Operators (Dorma) LCN, Stanley

D. Qualities, weights and sizes given are the minimum that will be accepted. It is the responsibility of the Hardware Supplier to follow the manufacturer's catalogue requirements for the proper size and weight of hardware in each case. All door sizes are to be noted on the door schedule and all hardware shall be in strict accordance with requirements of height, width, and thickness.

2.2 HINGES

A. Number of hinges per door: Two hinges or pivots are to be provided for doors up to and including five feet in height, and an additional hinge for each two- and-one-half feet (2-1/2'), or fraction thereof, of the height of the door.

B. Hinges for exterior doors shall be stainless steel, McKinney TA386 5” x 4.5” x

NRP x US32D.

C. Hinges for interior doors shall be steel, McKinney TA786 4.5” x 4.5” x NRP.

Width of hinges shall be determined by trim conditions.

D. Hinges are to be of three knuckle concealed bearing design, equipped with full radial thrust and lateral bearing assemblies. The bearing assemblies are to be permanently lubricated and sealed. All hinges are to have positive non-rising pins and a hole in the bottom tip for easy pin removal.

E. Conductor Hinges shall be McKinney “QC12”. Furnish “QC-C400P” Harnesses.

F. Center Hung Pivots shall be ABH 0370.

2.3 LOCKSETS

A. Unless noted otherwise, locksets shall be heavy-duty mortise type, Sargent “8200- CENF” Series Lever, in functions as noted in the HW Sets below.

B. All locks shall be furnished with 2-3/4 in. backset and wrought box strikes.

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 5 of 12

C. Strike lips shall standard ASA and be detailed to provide clearance for latchbolt at door frames with projecting trim. At Pairs. of Doors, furnish Straight Lip Strikes, 7/8- in. to center.

D. Furnish IC cylinders for all locking devices on this job.

2.4 EXIT DEVICES

A. Exit Devices shall be Sargent “19-43-80” Series in applications as noted in the HW Sets below.

B. Lever Trim shall match that of Locksets.

C. Furnish Cylinder Dogging for all non fire rated devices. Furnish Fire Rated devices where required.

2.5 CLOSERS

A. Overhead Surface Closers shall be Norton, non-sized, ADA approved, in the following applications, as follows:

Exterior Doors: 7500 (Top Jamb)

Interior Doors: 7500 Series. Furnish arm functions where noted in the HW Sets below.

B. Unless specified otherwise, closers shall be mounted on that side of the opening least objectionable to the public view. Provide parallel arm type at reverse bevel conditions.

C. The Hardware Schedule shall note the degrees of opening for all doors with closers.

Template and install closers for the maximum degree of opening.

D. Furnish all Closers with Delayed Action and Full Metal Covers.

E. LCN 4040XP and Town Steel TDC40 Series are acceptable equals.

2.6 STOPS

A. Wall Stops shall be Rockwood 405.

B. Overhead Stops shall be ABH N-3300-A (adjustable), unless otherwise specified.

C. Overhead Stops for Exterior Doors shall be ABH N-1020-SL.

2.7 GASKETING

A. Gasketing shall be Pemko S773BL, applied at head and jambs.

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 6 of 12

B. Automatic Door Bottoms shall be Pemko 434/420.

C. Sweeps shall be Pemko 315CN.

D. Overlapping Astragals shall be Pemko 375SP. Refer to ASA Strike dimension: Astragals shall not be notched.

E. Thresholds for exterior doors shall be Pemko 2005AT.

F. All Thresholds shall be cut-in around mullions, frame members, stops, mullions (not butted up against) and shall provide a continuous surface across the full width of the opening from jamb to jamb. All Thresholds shall be properly sealed, grouted and/or caulked and set in a full bed of mastic.

2.8 ADA POWER OPERATORS

A. ADA Power Operators shall be Dorma ED250 Series, Surface Mount. Furnish (2) BEA 10MS41-DA Touchless Actuators (locate as directed). Interface Operators with Electrified Hardware and Access Control System. Operators shall be furnished and installed by factory trained, AAADM Certified technicians.

2.9 MISCELLANEOUS

A. Offset Pulls shall be Rockwood BF158 x Type 12HD mounting.

B. Pull Plates shall be Rockwood 111-73C-73CL.

C. Kick Plates shall be Rockwood K1062-B4E-CSK, 10” high, except as noted. Width of plate shall be determined by the width of the door: plates shall be 2” LWOD on single doors and 1” on pairs of doors. Mops Plates shall be 4” High, 1” LWOD.

D. Self Latching Flush Bolts shall be Rockwood 2845/2945. Furnish 570 Dust Proof Strike.

E. Electric Strikes shall be HES 1500C x Fail Secure.

F. Coat Hooks shall be ABH A2016.

2.10 FINISHES - Unless otherwise noted, finish shall be as follows:

Hardware Item Finish

Butts (Interior) US26D Butts (Exterior) US32D Locksets US32D-SG Exit Devices US32D-SG Pulls US32D-MS

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 7 of 12

Flush Bolts US32D Protection Plates US32D: 062 Wall Stops US26D Closers 689

PART 3 - EXECUTION

3.1 MOUNTING POSITIONS

A. Heights given are center line heights from finished floor. Comply with recommendations of Builders' Hardware Manufacturers Association (BHMA), subject to approval, for heights of items not indicated; height is to center line unless otherwise indicated.

B. Hinges: Position top hinge five inches below head, bottom hinge ten inches above finished floor and intermediate hinge equally Spaced between top and bottom hinges.

C. Locksets/Exit Devices: Unless shown otherwise, locate center of Levers/Bars 40 inches above finished floor (or per Door Manufacturers standards).

D. Overhead Closers:

1. Verify each head condition prior to furnishing door closers.

2. Surface-mounted on Door: Surface shoe application for standard operation and soffit plate application for parallel arms. Provide Special shoe plates and brackets where Specified or where required by job conditions.

3. Set hardware plumb, level and in exact alignment and location. Conceal and countersink fasteners wherever possible.

3.2 ADJUSTING, CLEANING AND PROTECTION

A. Adjust hardware items to work smoothly, easily and correctly.

B Clean exposed surfaces using non-abrasive materials and methods recommended by the manufacturer of the hardware being cleaned. Remove and replace work which cannot be successfully cleaned, as judged solely by the Architect.

C. Provide temporary protection to ensure work being done without damage or deterioration at time of final acceptance. Levers shall be kept covered and other hardware shall be protected against damage until Substantial Completion of the Project.

Remove protections and reclean as necessary immediately prior to final acceptance.

3.3 COMPLETION AND CONTINUED MAINTENANCE

A. Before completion of work of this Section, inspect work with Architect and adjust and correct work to leave operating parts in perfect operating condition, jointing to adjacent material tight, surfaces without blemishes or stains, and defects or damaged work replaced or corrected.

3.4 HARDWARE SETS

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 8 of 12

A. Each Hardware Set listed below represents the complete hardware requirements for one opening (single door or pair of doors). Furnish the quantities required of each set for the work.

B. HW Sets that do not appear on the Door Schedule shall be considered “Not Used” and/or saved for future use.

C. Security items are listed below the individual Hardware Sets for Hardware Set coordination and templating for doors and frames.

D. The numbers used opposite locksets/exit devices to identify the function are Sargent numbers. Where “76” is indicated, furnish Knurled Outside Lever.

HW-1

Butts 1 Lockset 05 (Office) 1 Stop 1 Set Gasketing 1 Coat Hook

HW-1a Butts 1 Latchset 15 (Passage) 1 Stop 1 Set Gasketing 1 Automatic Door Bottom

HW-2

Butts 1 Lockset 05 (Office) 1 Stop 1 Set Gasketing

HW-3

Butts 1 Lockset 04 (Storeroom) 1 Closer 1 Kick Plate 1 Stop 1 Set Gasketing

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 9 of 12

HW-3a Butts 1 Lockset 04 (Storeroom) 1 Set Self Latching Flush Bolts 1 Closer Active Leaf 2 Kick Plates 2 Stops 1 Set Gasketing 1 Overlapping Astragal

HW-4

1 Conductor Hinge Butts 1 Electric Lockset RX-71 (Fail Secure) 1 Closer 1 Kick Plate 1 Stop 1 Set Gasketing CR, DC & PS By Security 24V

HW-4.1

Butts 1 Latchset 15 (Passage) 1 Electric Strike 1 ADA Power Operator 1 Kick Plate 1 Stop 1 Set Gasketing 120V

HW-4a 1 Conductor Hinge Butts 1 Electric Exit Device 19-43-55-56-8806-ET (Storeroom) 1 ADA Power Operator 1 Kick Plate 1 Stop 1 Set Gasketing CR, DC & PS By Security 24V/120V

HW-5

1 Conductor Hinge Butts 1 Electric Exit Device 12-19-43-55-76-8976-ET (Fail Secure) 1 Closer 1 Kick Plate 1 Stop 1 Set Gasketing CR, DC & PS By Security 24V

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 10 of 12

HW-6

1 Conductor Hinge Butts 1 Electric Exit Device 19-43-55-56-8804 (Key only) 1 Pull Offset 1 Closer 1 Kick Plate 1 OH Stop 1 Set Gasketing 1 Sweep 1 Threshold CR, DC & PS By Security 24V

HW-6.1

1 Conductor Hinge Butts 1 Electric Exit Device 19-43-55-56-AD8504 (Key only) 1 Pull Offset 1 Closer 1 OH Stop Gasketing By Frame Manufacturer 1 Threshold CR, DC & PS By Security 24V

HW-7

Butts 1 Privacy Set V20-65 (Indicator) 1 Closer 1 Kick Plate 1 Mop Plate 1 Stop 1 Set Gasketing

HW-8

All Hardware By Door Manufacturer, except:

1 Locking Pull LP3301-DBU

HW-9

1 Conductor Hinge Butts 1 Electric Lockset RX-76-71 (Fail Secure) 1 Closer 1 Kick Plate 1 Stop 1 Set Gasketing 1 Automatic Door Bottom

24V

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 11 of 12

HW-10

1 Conductor Hinge Butts 1 Electric Lockset RX-76-71 x Key Inside (Fail Secure) 1 Closer 1 Kick Plate 1 Stop 1 Set Gasketing 1 Sweep 1 Threshold CR, DC & PS By Security 24V

HW-11

Butts 1 Lockset 05 (Office) 1 Stop 1 Set Gasketing

HW-12

Butts 1 Latchset 15 (Passage) 1 Closer 1 Kick Plate 1 Stop 1 Set Gasketing

HW-13

Butts 1 Pull Plate 1 Closer 1 Kick Plate 1 Stop 1 Set Gasketing

HW-14

1 Conductor Hinge Butts 1 Electric Lockset RX-04 (Storeroom) 1 Electric Strike 1 ADA Power Operator 1 Kick Plate 1 Stop 1 Set Gasketing

24V/120V

MANCHESTER, NH

DOOR HARDWARE

08 71 00 - page 12 of 12

HW-15

1 Conductor Continuous Hinge Markar FM300-EL12 1 Electric Lockset PHR-NAC-82281 (Fail Secure) 1 Closer 1 Kick Plate 1 Stop 1 Set Gasketing CR, DC & PS By Security 24V

HW-MISC

1 Plate 3” x 36” x US32D 6 Coat Hooks ABH A2016 (equally spaced on Plate) Locate as directed in Workstation SWA112

END OF SECTION