This document is a set of architectural demolition and construction drawings for telecommunications room upgrades at the Carl Vinson VA Medical Center in Dublin, Georgia. The drawings, labeled as Volume 2 of 4, comprehensively detail demolition and reconstruction plans for telecommunications rooms across 13 different buildings within the medical center campus. The plans include floor and ceiling demolition layouts, specific room-by-room renovation instructions, and technical specifications for each telecom room, such as installing new fire-rated plywood backboards, flooring, doors, signage, electrical components, and HVAC equipment. The project involves systematic infrastructure improvements, with each building's telecom rooms receiving standardized upgrades to enhance communication infrastructure and meet specific technical requirements.

View the file

Other files for this federal contract opportunity

Other files attached to Z2DZ--EHRM Infrastructure Upgrades Dublin, GA Project 557-22-700, newest first.
File Type Posted
Atch 1 - PreBid RFIs 7.30.2025.xlsx XLSX spreadsheet
36C77625B0013 0004.docx DOCX document
Atch 1 - PreBid RFIs 7.24.2025.xlsx XLSX spreadsheet
36C77625B0013 0003.docx DOCX document
Atch 3 - ICRALevel_Department - Dublin - 557-22-700.pdf PDF
Atch 2 - Annual Hydrant Flow Report_9JUL25 - Dublin - 557-22-700.xlsx XLSX spreadsheet
36C77625B0013 0002.docx DOCX document
Atch 8 - Dublin EHRM_ACM_Matrix - Dublin - 557-22-700.xlsx XLSX spreadsheet
Atch 6 - 013323 Shop Drawings - Dublin - 557-22-700.pdf PDF
Atch 5 - 013216.15 Project Sched_Small - Dublin - 557-22-700.pdf PDF
Atch 4 - Virtual Bid Opening Information - Dublin - 557-22-700.pdf PDF
Atch 9 - 22-192 Existing Cable Counts by TR - Dublin - 557-22-700.xlsx XLSX spreadsheet
Atch 7 - 028333.13 Lead Based Paint - Dublin - 557-22-700.pdf PDF
Atch 1 - PreBid RFIs.xlsx XLSX spreadsheet
36C77625B0013 0001.docx DOCX document
Attachment 1 - Site Visit Sign-in Sheet - Dublin EHRM.pdf PDF
Attachment 2 - Site Visit Agenda - Dublin EHRM.pdf PDF
Attachment 15 - Drwg 82 of 91 REVISED.pdf PDF
Attachment 13 - VAAR LOS Construction.docx DOCX document
Attachment 11 - SOW Atch 4 Specifications.pdf PDF
Attachment 8 - SOW Atch 1 Design Guide Telecom Spaces.pdf PDF
Attachment 5 - Drawings 4 of 4 - Dublin GA - EHRM.pdf PDF
Attachment 10 - SOW Atch 3 Elec Panel Labeling.pdf PDF
Attachment 14 - Division Cost Breakdown.xlsx XLSX spreadsheet
Attachment 9 - SOW Atch 2 EUD Requirements.pdf PDF
Attachment 6 - Site Visit Instructions.docx DOCX document
Attachment 1 - Specifications - Dublin GA - EHRM.pdf PDF
Attachment 12 - Wage Rates - GA20250095 02072025.pdf PDF
Attachment 7 - SOW - Dublin GA - EHRM.pdf PDF
Attachment 4 - Drawings 3 of 4 - Dublin GA - EHRM.pdf PDF
Attachment 2 - Drawings 1 of 4 - Dublin GA - EHRM.pdf PDF
36C77625B0013.docx DOCX document
Show all 32

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

7' -0

5'-0"

VAN

ACCESSIBLE

LOADING AREA

SF

SF

EA

SE

MEN

T A

PP

RO

XIM

AT

EL

Y S

HO

WN

' E

XIS

TIN

G W

AT

ER

LI

NE

EA

SE

MEN

T

2.5" PLASTIC WITNESS POST

1/2" REBAR FOUND IN

CONCRETE MONUMENT

CONCRETE NAIL FOUND

Bldg 5 Gen

Bldg 4 Gen

Water Tower Gen

Bldg 8 Gen

Circuit 2 Gen

OBSERVATION MONITORING WELL

UP

UP

DEANE + STROLLO, LLC718 Virginia DriveOrlando, FL. 32803T: (407) 423-5355 F: (407) 422-5994

H

IL

LC

R

ES

T

PK

W

Y.

BE

LL

EV

UE

R D.

INDUSTRIAL BLVD.

INDUSTRIAL BLVD.

H

IL

LC

R

ES

T

PK

W

Y.

FAIRVIEW PARK HOSPITAL

FA

IR

VI

EW

P

AR

K

DR

IV

E

Bldg 27 Gen

F

F

F

F

F F

F

F

FF

F

F

SIGN

NE

FF

PL

AC

E

NE

FF

P

LA

CE

BE

LL

EV

UE

AV

EN

UE

AL

EX

AN

DE

R D

RIV

E

JO

HNSO

N ST

REE

T

PARKING

PARKING

PARKING

PARKING

PARKING

PARKING

METAL BLDGS.BLDG. 31

BLDG. 46

BLDG. 36

BLDG. 24

BLDG. 43

BLDG. 32

BLDG. 39

GAZEBO

BLDG. 68

BLDG. 67

BLDG. 21

LAKE LEISURE

AC

AC

PARKING

PARKING

BLDG. 34

BLDG. 35

STEPS

RAMP

PATIO

R

AM

P 1:

S

LO

PE

R

AM

P 1:

S

LO

PE

R

AM

P 1:

S

LO

PE

LA

N

D

IN

G

VAN VAN VAN VAN

RAMP

CONCRETE DITCH

CONCRETE

CONCRETE

CONCRETE

SLAB

SLAB

NEW PARKING

CTCT

AC

AC

AC

AC

OBSERVATION MONITORING WELL

BLDG. 17

BLDG.

BLDG. 47

BLDG. 41

BLDG

BLDG. 63

BLDG. 81

BLDG. 82

BLDG. 27

BLDG.

BLDG. 71BLDG. 28

BLDG. 66

CO

OL

IN

G

TO

W

ER

BLDG. 69

BLDG. 30

WATER TANK

BLDG. 5

BLDG. 3 BLDG. 1

BLDG. 9

BLDG. 13

BLDG. 11

BLDG. 2

BLDG. 40

BLDG. 4

BLDG. 6

BLDG. 8

BLDG. 10

BLDG. 12

BLDG. 85

BLDG. 14

BLDG. 86

BLDG. 25

BLDG. 26

BLDG. 29

BLDG. 15

BLDG. 19

GAZEBO

SUBSTATION

BLDG. 44

BLDG. 62

BLDG. 84

BLDG.

Bldg 2 Gen

FUEL

TANK

MRI

BLDG.29

ANNEX

New Water Tower Location

Bldg.10

New Chiller Plant

BLDG. 87

BLACKWOOD DRIVE

EX

IS

TIN

G

JO

HN

SO

N

ST

RE

ET

JOHNSON STREET

ALEXANDER DRIVE

BLACKWOOD DRIVE

TROJAKOWSKI AVENUE

EVANS AVENUE

TROJAKOWSKI AVENUE

EVANS AVENUE

CROWLEY AVENUE

CROWLEY AVENUE

VETERANS PARKWAY US HWY 80

VETERANS PARKWAY US HWY 80 VETERANS PARKWAY US HWY 80

JOHNSON STREET

BLACKWOOD DRIVE

AL

EX

AN

DE

R D

RIV

E

JOHNSON STREET

THOMAS LANE

THOMAS LANE

NORTHWEST DRIVE

JOHNSON STREET

EVANS AVENUE

TROJAKOWSKI AVENUE

NEW JO

HNSON STREET WEST

SHADED BUILDINGS REPRESENT

PROJECT SCOPE

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027

Engineers Architects Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

PROJECT SITE MAP PROJECT LOCATION MAP

/6

/2

9:

:1

PM

C :\U se rs

\a pu lle n\

D oc um en ts \M

S_

-1

-V A

D ub lin E

H R

M _G

EN

_R

_a pu lle nV D

XT

7.

rv t

GA-001

COVER

1 1ANP

EHRM INFRASTRUCTURE

UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027 NOVEMBER 8, 2024

100% BID DOCUMENTS

557-22-70022-192

VARIOUS

EHRM INFRASTRUCTURE UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027

VA PROJECT #: 557-22-700

DJR

NORTH

NORTH

DRAWING LIST - VOLUME 2 OF 4

SHEET NUMBER SHEET NAME DWG OF DWG

GENERAL

GA-001 COVER 1 1

ARCHITECTURAL

A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES 1 56

01.A-411 BUILDING 1, LEVEL A, TELECOM ROOM 101-1 PLANS 2 56

01.A-421 BUILDING 1, LEVEL B, TELECOM ROOM 207-1 PLANS 3 56

02.A-401 BUILDING 2, LEVEL C, TELECOM ROOM BM123B-2 PLANS 4 56

02.A-411 BUILDING 2, LEVEL A, TELECOM ROOM 104-2 PLANS 5 56

02.A-421 BUILDING 2, LEVEL B, TELECOM ROOM 209A-2 PLANS 6 56

03.A-401 BUILDING 3, LEVEL C, TELECOM ROOM BM101A-3 PLANS 7 56

03.A-411 BUILDING 3, LEVEL A, TELECOM ROOM 112A-3 PLANS 8 56

03.A-421 BUILDING 3, LEVEL B, TELECOM ROOM 219-3 PLANS 9 56

04.A-401 BUILDING 4, LEVEL C, TELECOM ROOM BM105-4 PLANS 10 56

04.A-411 BUILDING 4, LEVEL A, TELECOM ROOM 118-4 PLANS 11 56

04.A-421 BUILDING 4, LEVEL B, TELECOM ROOM 202-4 PLANS 12 56

05.A-411 BUILDING 5, LEVEL A, TELECOM ROOM C137-5 PLANS 13 56

06.A-411 BUILDING 6, LEVEL A, TELECOM ROOM 103-6 PLANS 14 56

06.A-421 BUILDING 6, LEVEL B, TELECOM ROOM 226-6 PLANS 15 56

08.A-411 BUILDING 8, LEVEL A, TELECOM ROOM 172C-8 PLANS 16 56

08.A-421 BUILDING 8, LEVEL B, TELECOM ROOM 213-8 PLANS 17 56

09.A-421 BUILDING 9, LEVEL B, TELECOM ROOM 210A-9 PLANS 18 56

10.A-401 BUILDING 10, LEVEL C, TELECOM ROOM BM107A-10 PLANS 19 56

10.A-411 BUILDING 10, LEVEL A, TELECOM ROOM 130-10 PLANS 20 56

10.A-421 BUILDING 10, LEVEL B, TELECOM ROOM 205-10 PLANS 21 56

11.A-401 BUILDING 11, LEVEL C, TELECOM ROOM BM101A-11 PLANS 22 56

11.A-411 BUILDING 11, LEVEL A, TELECOM ROOM 125-11 PLANS 23 56

11.A-421 BUILDING 11, LEVEL B, TELECOM ROOM 235-11 PLANS 24 56

12.A-401 BUILDING 12, LEVEL C, TELECOM ROOM BM103A-12 PLANS 25 56

12.A-411 BUILDING 12, LEVEL A, TELECOM ROOM 117A-12 PLANS 26 56

12.A-421 BUILDING 12, LEVEL B, TELECOM ROOM 232A-12 PLANS 27 56

13.A-411 BUILDING 13, LEVEL A, TELECOM ROOM 141-13 PLANS 28 56

13.A-421 BUILDING 13, LEVEL B, TELECOM ROOM 224-13 PLANS 29 56

14.A-401 BUILDING 14, LEVEL C, TELECOM ROOM BM104A-14 PLANS 30 56

14.A-411 BUILDING 14, LEVEL A, TELECOM ROOM 101A-14 PLANS 31 56

14.A-421 BUILDING 14, LEVEL B, TELECOM ROOM 232-14 PLANS 32 56

15.A-411 BUILDING 15, LEVEL A, TELECOM ROOM 107-15 PLANS 33 56

15.A-421 BUILDING 15, LEVEL B, TELECOM ROOM 230-15 PLANS 34 56

16.A-401 BUILDING 16, LEVEL C, TELECOM ROOM B11A-16 PLANS 35 56

16.A-421 BUILDING 16, LEVEL B, TELECOM ROOM 216-16 PLANS 36 56

17.A-411 BUILDING 17, LEVEL A, TELECOM ROOM 111-17 PLANS 37 56

17.A-421 BUILDING 17, LEVEL B, TELECOM ROOM 205-17 PLANS 38 56

19.A-411 BUILDING 19, LEVEL A, TELECOM ROOM 117-19 PLANS 39 56

19.A-421 BUILDING 19, LEVEL B, TELECOM ROOM 216A-19 PLANS 40 56

25.A-411 BUILDING 25, LEVEL A, TELECOM ROOM 101A-25 PLANS 41 56

26.A-401 BUILDING 26, LEVEL C, TELECOM ENCLOSURE BM108B-26 PLANS 42 56

26.A-411 BUILDING 26, LEVEL A, TELECOM ROOM 106-26 PLANS 43 56

27.A-411 BUILDING 27, LEVEL A, TELECOM ROOM 107-27 PLANS 44 56

28.A-411 BUILDING 28, LEVEL A, TELECOM ROOM 108-28 PLANS 45 56

29.A-411 BUILDING 29, LEVEL A, TELECOM ENCLOSURE 113A-29 PLANS 46 56

30.A-411 BUILDING 30, LEVEL A, TELECOM ENCLOSURE 104-30 PLANS 47 56

85.A-411 BUILDING 85, LEVEL A, TELECOM ROOM 121-85 PLANS 48 56

86.A-411 BUILDING 86, LEVEL A, TELECOM ROOM 106-86 PLANS 49 56

87.A-411 BUILDING 87, LEVEL A, TELECOM ROOM 120-87 PLANS 50 56

87.A-412 BUILDING 87, LEVEL A, TELECOM ROOM 169-87 PLANS 51 56

89.A-411 BUILDING 89, LEVEL A, TELECOM ROOM 1215-89 PLANS 52 56

A-506 PARTITION TYPES AND ARCHITECTURAL DETAILS 53 56

A-601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 54 56

A-602 GENERAL NOTES, BASIS OF DESIGN, ABBREVIATIONS AND FINISH DETAILS 55 56

A-603 ROOM FINISH SCHEDULE 56 56

VOLUME 2 OF 4

5070L

IC

E N

S E D A RC H I T ECT

DA

V ID J . REICHARD

NOR T H CA RO L I NA

Docusign Envelope ID: 4081B0C2-2BE7-4DDD-B6CF-B1CCFE1038E3

11/7/2024

DEMOLITION KEYNOTE

DOOR NUMBERTYPICAL KEYNOTE CEILING/ SOFFIT

HEIGHT 10

CR CARD READER

X'-X" A.F.F.

1.

2.

3.

4.

5.

1.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

25.

1.

2.

GENERAL

ALL EXISTING CONDITIONS ARE BASED ON THE BEST AVAILABLE INFORMATION AT THE TIME OF SURVEY AND

VISUAL INSPECTION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS.

ELEMENTS SHOWN WITH LIGHT GRAY LINES ARE EXISTING TO REMAIN. ELEMENTS SHOWN WITH DARK DASHED LINES ARE EXISTING TO BE DEMOLISHED. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO, THOSE

ELEMENTS SHOWN.

ALL WORK SHALL BE COORDINATED BETWEEN TRADES

FOR FINISHES IN ALL NEW TELECOM ROOMS, SEE ROOM FINISH SCHEDULE ON SHEET A-602.

ALL WORK SHALL BE COORDINATED WITH THE COR TO MINIMIZE DISRUPTION OF AREAS OUTSIDE OF THE

PROJECT LIMITS OF WORK.

PHASING

THIS PROJECT WILL BE IMPLEMENTED IN PHASES. THE FIRST PHASE WILL INCLUDE THE HEAD-END EQUIPMENT AND FIBER IMPROVEMENTS TO ACHIEVE THE REDUNDANCY FEEDING OF THE TELECOMMUNICATION ROOMS.

THE SECOND PHASE WILL CONSTRUCT ONE OR MORE TELECOMMUNICATIONS ROOMS FOR EACH BUILDING IN A TIMED SEQUENCE UNDER A CONSTRUCTION SCHEDULE PROVIDED BY THE CONTRACTOR AND APPROVED BY THE COR, WITH HVAC SYSTEM TO BE INSTALLED AND ACTIVE. THE THIRD PHASE WILL INCLUDE DISTRIBUTION OF CABLING FROM THE COMPLETED TELECOMMUNICATION ROOMS TO THE DATA RECEPTACLES WITHIN THE APPROPRIATE DISTANCE OF THOSE ROOMS AND CONSTRUCTION OF MORE TELECOMMUNICATIONS ROOMS.

ALL WORK

INDICATIONS OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN FOR GENERAL SCOPE DEFINITION AND REFLECT THE UNDERSTANDING OF THE DESIGNERS AS TO THE LIMITATIONS OF THE WORK AREA. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY AGREEMENT BETWEEN THE COR/VA AND THE CONTRACTOR

BEFORE THE START OF THE WORK.

DRAWINGS ARE PREPARED USING PRODUCT DIMENSIONS AND DETAILS FROM THE BASIS OF DESIGN PRODUCT. PRODUCTS MAY CHANGE IN DIMENSION AND DETAIL BEFORE THEY ARE INCORPORATED INTO WORK. PRODUCTS FROM OTHER MANUFACTURER'S ARE ALSO ACCEPTABLE. DIMENSIONS AND DETAILS FOR ALTERNATE PRODUCTS MAY VERY FROM BASIS OF DESIGN. CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL PRODUCTS TO BE INCORPORATED INTO WORK (INCLUDING THICKNESS FOR RECESSED OR SEMI-RECESSED PRODUCTS) AND IS RESPONSIBLE FOR ACCOMMODATING AND COORDINATING CHANGES TO OTHER MATERIALS OR PRODUCTS THAT ARE NECESSARY BECAUSE OF THESE DIFFERENCES.

THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR CONVENIENCE. THE SEPARATIONS ARE USED ONLY FOR THE PURPOSES OF CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR LIMIT THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS AND SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS ARE SEPARATED IN NO WAY SUGGESTS THAT THE WORK IS NOT TO

BE CONSTRUCTED AS A COMPLETE, INTEGRATED AND UNIFIED WHOLE.

THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY SPECIFIC ENGINEERING DISCIPLINES ARE COMPLEMENTARY; ITEMS SHOWN IN ANY ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF AN INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR WITHIN EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION OR INTERPRETATIONS FROM THE COR/VA PRIOR TO BIDDING.

WHERE INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING, AND WHERE THE ACTUAL SOLUTION OR INTENT CANNOT BE REASONABLY INFERRED, THE CONTRACTOR SHALL PROVIDE THE BETTER QUALITY OR

GREATER QUAINTLY OF WORK.

THE CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL FIELD CONDITIONS (BOTH EXPOSED AND CONCEALED) AND DIMENSIONS AS THEY RELATE TO THIS PROJECT, FOR EACH PHASE. SHOULD DISCREPANCIES EXIST BETWEEN THE WORK INDICATED AND ACTUAL FIELD CONDITIONS. NOTIFY THE COR/VA PRIOR TO PROCEEDING

WITH THE WORK.

THE CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH OTHER TRADES REGARDING THE LOCATION AND SIZE OF PIPES, EQUIPMENT, FIXTURE, CONDUIT, DUCTS, OPENINGS, SWITCHES, OUTLETS, ETC., SO THAT INTERFERENCE BETWEEN THE INSTALLATION OR THE PROGRESS OF THE WORK OF ANY CONTRACTOR OR THE SUBCONTRACTOR ON THE PROJECT CAN BE MINIMIZED IN THE FIELD. SEE SPEC SECTION 01 33 23 SHOP

DRAWINGS.

IN SPACES WITH HIGH CONCENTRATION OF INTER-RELATED EQUIPMENT, PIPING, CONDUIT, AND DUCTWORK (SUCH AS CORRIDORS, MECHANICAL ROOMS, TELECOM ROOMS, ETC), PROVIDE COORDINATION DRAWINGS CLEARLY DEPICTING THE LAYOUT (BOTH PLAN AND ELEVATION, OR PERSPECTIVE) BASED ON FIELD CONDITION. CONTRACTOR TO CLEARLY DEFINE IN ADVANCE OF CONSTRUCTION THE RELATIONSHIP OF ALL PIPING CONDUIT, DUCTWORK, AND EQUIPMENT. DEMONSTRATE CLEARANCE SPACE SUFFICIENT TO SERVICE

THE EQUIPMENT. SEE SPEC SECTION 01 33 23 SHOP DRAWINGS.

COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES.

CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL CONSTRUCTION PERMITS.

CONTRACTOR SHALL PREPARE A PLAN SHOWING LAYDOWN AREA, SECURITY FENCE, DUMPSTER LOCATION, SCAFFOLDING, AND ACCESS FOR COR/VA REVIEW AND APPROVAL.

PROVIDE METAL BACKING AT WALLS AS REQUIRED FOR MOUNTING OF WALL-MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO WALL PROTECTION, SHELVING, CASEWORK, EQUIPMENT, PLUMBING, ETC. CUT AND PATCH GYP BD IN EXISTING WALLS FOR INSTALLATION OF NEW METAL BACKING WHERE REQUIRED. PROVIDE METAL BACKING IN WALLS AT WATER CLOSET LOCATIONS FOR GRAB BAR INSTALLATION WHETHER GRAB BARS ARE

INDICATED OR NOT.

PROVIDE SUPPLEMENTAL FRAMING AT WALL OPENINGS INCLUDING KING STUDS, JACK STUDS, AND CRIPPLE

STUDS, AS REQUIRED FOR COMPLETION OF THE WORK.

PROVIDE STRUCTURAL SUPPORTS ABOVE CEILING WHERE REQUIRED FOR CEILING HUNG EQUIPMENT.

FURR OUT AROUND COLUMNS, PIPES, UTILITIES, ETC., WITH THE MINIMUM DEPTH NECESSARY TO CONCEAL

PIPES.

CLEAN PAINT OFF ALL NEW AND EXISTING FIRE LABELS IN SCOPE OF WORK TO ALLOW READABILITY.

ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.

ALL PRESSURE TREATED WOOD SHALL BE ISOLATED FROM METAL DECK AND / OR METAL STUDS TO PREVENT

CORROSION. ALL FASTENERS IN PRESSURE TREATED WOOD SHALL BE STAINLESS STEEL.

PROVIDE SEALANT AT ALL INTERSECTIONS / JOINTS BETWEEN DIFFERENT MATERIALS.

ALL ITEMS AND MATERIALS SHOWN, INDICATED, OR REQUIRED FOR A COMPLETE PROJECT SHALL BE

PROVIDED AND INSTALLED BY THE CONTRACTOR (UNO).

DRAWINGS SCALES INDICATED ARE FOR REFERENCE ONLY, WRITTEN DIMENSIONS SHALL GOVERN.

SEAL ANY THRU WALL PENETRATIONS AT EXTERIOR WALLS FROM MEP EQUIPMENT LINES.

CONTRACTOR TO PROVIDE FIRE RETARDANT CAULK AT ANY PENETRATIONS TO FIRE TREATMENT PLYWOOD.

CONTRACTOR TO ASSUME ALL CORRIDOR WALLS 1HR RATED AND ALL FLOOR PENETRATIONS 2HR RATED, UNO. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCY.

AT ALL NEW FIRE EXTINGUISHER CABINETS, PROVIDE A NEW CLEAN AGENT FIRE EXTINGUISHER WITHIN 75'-0"

OF THE TELECOM ROOM.

WHERE INFORMATION IS NOT INDICATED ON FIRE RATINGS, LIGHT DIFFUSERS, MECHANICAL DIFFUSERS OR FIRE PROTECTION, ON CEILING GRIDS, THE INFORMATION WAS NOT AVAILABLE FROM THE VA AT THE TIME OF

SUBMISSION.

RENOVATION

PROTECT EXISTING ITEMS, EQUIPMENT, FINISHES, ETC. TO REMAIN. REPAIR / REPLACE / RESTORE, CONDITIONS THAT ARE DAMAGED OR DISTURBED AS A RESULT OF DEMOLITION OR NEW WORK.

CONTRACTOR SHALL MINIMIZE DOWNTIME ASSOCIATED WITH SCHEDULED SHUTDOWNS. COORDINATE WITH

COR/VA.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

1.

2.

1.

2.

3.

GENERAL

KEYNOTES AND DRAWINGS ARE INTENDED TO GRAPHICALLY REPRESENT GENERAL WORK AND DO NOT PORTRAY THE FULL SCOPE OF THE PROJECT. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS. THIS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF PROVIDING ALL DEMOLITION REQUIRED FOR

COMPLETION OF THE PROJECT.

REMOVE EXISTING CONSTRUCTION AS DESIGNATED AND CLEAR AREA OF DEBRIS PRIOR TO PROCEEDING WITH

NEW CONSTRUCTION.

VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY COR/VA AND ARCHITECT OF ANY

CONFLICTS PRIOR TO PROCEEDING WITH DEMOLITION.

COORDINATE WITH COR/VA FOR WORKING HOURS ALLOWED FOR DEMOLITION AND WASTE REMOVAL.

COORDINATE WITH COR/VA FOR SCHEDULED USE OF CONSTRUCTION ACCESS ROUTES (INCLUDING USE OF FREIGHT ELEVATOR IF REQUIRED), TRANSPORTATION, AND LOCATIONS OF ITEMS SUCH AS DUMPSTERS.

COORDINATE WITH COR/VA FOR ANY DOWNTIME ON ALL BUILDING SYSTEMS. PROVIDE TEMPORARY SERVICES

DURING INTERRUPTIONS OF EXISTING UTILITIES.

CONDUCT DEMOLITION TO MINIMIZE INTERFERENCE WITH VA'S NORMAL OPERATION AND WITH ADJACENT

BUILDING AREAS.

ALL DEMOLITION WORK SHALL BE PERFORMED WITH DUE CARE AND DILIGENCE IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTIONS OF SERVICE OR CONCEALED UTILITIES INTENDED TO REMAIN IN SERVICE (INCLUDING FIRE PROTECTION). DISCOVERY OF UTILITIES OR CONDITIONS DIFFERING FROM THOSE

INDICATED OR THAT ARE NOT IDENTIFIED, SHALL BE REPORTED TO THE COR/VA.

DO NOT ENCROACH ON ADJACENT OCCUPIED AREAS NOT IDENTIFIED WITHIN THE SCOPE OF THE PROJECT

(UNO).

RECORD EXISTING CONDITIONS BY USE OF ANY COMBINATION OF MEASURED DRAWINGS AND

PRECONSTRUCTION PHOTOGRAPHS.

CONTRACTOR SHALL NOTIFY COR/VA OF ANY AREA REQUIRING DEMOLITION OTHER THAN SHOWN IN THESE DRAWINGS DUE TO UNFORESEEN CONDITIONS, TO ACCOMMODATE INSTALLATION OF ALL OTHER TRADES (INCLUDING ROOF PENETRATIONS, ELECTRICAL, OR DATA). AFTER SUCH DEMOLITION AND INSTALLATION, PATCH / REPAIR MATERIALS AND FINISHES TO MATCH EXISTING.

CONTRACTOR SHALL PROTECT AREA ADJACENT TO THE DEMOLITION AND NEW CONSTRUCTION WORK TO PREVENT DAMAGES. IF DAMAGED, PATCH / REPAIR. REPAIR OR REPLACE ITEMS DAMAGED DURING

CONSTRUCTION ACTIVITIES AT NO ADDITIONAL COST.

AT AREAS INDICATED TO BE PATCHED AND REPAIRED FOR ADDITION AND RENOVATION PROJECTS, THE CONSTRUCTION AND ASSEMBLY OF THE PATCH / REPAIR SHALL MATCH THE ASSEMBLY AND INTEGRITY OF THE ADJACENT EXISTING CONSTRUCTION, FOR FIRE RATING, MATERIALS, FINISH, THICKNESS, AND QUALITY.

REFER TO STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, VENDOR DRAWINGS, AND SPECIFICATIONS

FOR ADDITIONAL DEMOLITION ITEMS AND INFORMATION.

COORDINATE WITH COR/VA ON WHAT ITEMS ARE TO BE REMOVED, DISPOSED OF, SALVAGED, AND/OR

REINSTALLED.

- REMOVED & DISPOSED OF ITEMS: SHALL BE PROPERLY DISPOSED OF, OFF PROJECT GROUNDS.

COORDINATE WITH COR/VA.

- REMOVED & SALVAGED ITEMS: SHALL BE CLEANED, PACKED OR CRATED AFTER CLEANING, AND LABELED TO IDENTIFY THE CONTENTS OF CONTAINERS. PROTECT AND TRANSPORT ITEMS TO VA STORAGE AREA.

- REMOVED & REINSTALLED ITEMS: SHALL BE CLEANED AND REPAIRED TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED USE, PACKED OR CRATED AFTER CLEANING AND LABELED TO IDENTIFY THE CONTENTS OF THE CONTAINERS. PROTECT AND TRANSPORT ITEMS TO TEMPORARY STORAGE, REINSTALL

ITEMS IN LOCATIONS INDICATED.

PATCH / REPAIR ALL MATERIALS AND SURFACES CUT OR DAMAGED DURING DEMOLITION WITH MEANS AND

METHODS SO AS TO NOT TO VOID EXISTING WARRANTIES.

AFTER REMOVAL OF EXISTING CONCRETE OR CMU WALLS. FILL FLOOR VOIDS UP TO FINISH CONCRETE LEVEL

AND PERFORM FLOOR LEVELING FOR ENTIRE AREA OF RENOVATION.

WHERE EXISTING CONSTRUCTION IS TO BE CUT OR REMOVED, PROVIDE SMOOTH AND STRAIGHT CUT JOINTS THAT ARE STRUCTURALLY SOUND. PATCH / REPAIR ADJACENT SURFACES TO MATCH EXISTING AND PROVIDE

IMPERCEPTIBLE TRANSITION (UNO).

WHERE DEMOLITION WORK UNCOVERS OR LEAVES OPENINGS IN PARTITIONS / CEILINGS OR INCOMPLETE PARTITIONS / CEILINGS, EXTEND, RESTORE, AND/OR CLOSE OPENING IN PARTITIONS / CEILINGS AS INDICATED AND/OR AS REQUIRED TO MAINTAIN FIRE RATINGS. MATCH EXISTING CONSTRUCTION, (UNO), WITHIN THE LIMITS AND TOLERANCES FOR MATERIALS AS SPECIFIED OR RECOMMENDED BY THE MANUFACTURER.

REFINISH SURFACES TO ALIGN FLUSH WITH EXISTING.

CEASE OPERATIONS IMMEDIATELY IF THE STRUCTURE APPEARS TO BE IN DANGER AND NOTIFY THE COR/VA

AND ARCHITECT/ENGINEER. DO NOT RESUME OPERATIONS UNTIL DIRECTED.

CONTRACTOR IS RESPONSIBLE FOR SHORING AND TEMPORARY SUPPORT OF STRUCTURE NECESSARY DUE TO DEMOLITION IN ORDER TO MAINTAIN THE INTEGRITY OF RELEVANT STRUCTURE. CONTRACTOR SHALL PROVIDE ENGINEERED PLANS FOR SHORING SIGNED AND SEALED BY REGISTERED ENGINEER LICENSED IN

THE STATE IN WHICH THE PROJECT IS LOCATED.

ALL EXISTING SIGNAGE NOT BEING REUSED IN THE PROJECT TO BE HANDED OVER TO COR/VA DURING

DEMOLITION.

LIFE SAFETY

ALL NECESSARY PATHS OF EGRESS AND EXITS SHALL BE MAINTAINED, PROTECTED AND CLEAR, UNLESS AN

ALTERNATIVE EGRESS PATH OR METHOD IS PROVIDED WHICH MEETS THE RELEVANT CODES.

DO NOT DISABLE OR DISRUPT ANY BUILDING FIRE OR LIFE SAFETY SYSTEMS WITHOUT PRIOR WRITTEN NOTICE

TO THE COR/VA.

HAZARDOUS MATERIALS

IF HAZARDOUS MATERIALS ARE SUSPECTED OR ENCOUNTERED, IMMEDIATELY SUSPEND WORK IN AREA OF SUSPECTED CONTAMINATION, WITHDRAW FROM AREA, AND NOTIFY COR/VA AND ARCHITECT/ENGINEER IN

WRITING.

CONTRACTOR SHALL COORDINATE WITH COR/VA AND/OR ARCHITECT/ENGINEER ON RESPONSIBILITY OF

REMOVAL OF HAZARDOUS MATERIALS (KNOWN OR UNKNOWN) PRIOR TO CONTRACT.

COMPLY WITH REQUIREMENTS OF EPA, NATIONAL EMISSION STANDARDS, OSHA REGULATIONS, AND ALL

OTHER APPLICABLE REGULATIONS ON HAZARDOUS MATERIALS.

1.

2.

3.

4.

GENERAL

CONTRACTOR A IS RESPONSIBLE FOR REMOVING AND RELOCATING ALL EXISTING FURNITURE, FIXTURES AND

EQUIPMENT FOR RENOVATION PROJECTS PRIOR TO CONSTRUCTION.

REFER TO MECHANICAL, ELECTRICAL, PLUMBING, FIRE ALARM AND LOW VOLTAGE DRAWINGS FOR ADDITIONAL

REQUIRED UTILITY CONNECTIONS AND LOCATIONS.

REFER TO G-002 FOR STANDARD MOUNTING HEIGHTS. REFER TO EQUIPMENT DRAWINGS FOR LOCATIONS AND ADDITIONAL DIMENSIONS. PROVIDE 16 GAUGE BACKING FOR ALL WALL MOUNTED EQUIPMENT AS REQUIRED BY

THE MANUFACTURER’S REQUIREMENTS FOR INSTALLATION.

WHEREVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, BRACING, FOUNDATIONS, ASSOCIATED WIRING CONDUIT, ETC. AFTER REMOVAL, AFFECTED CONSTRUCTION AND SURFACES, SUCH AS FLOORS, WALLS, BASES, AND CEILINGS, SHALL

BE FINISHED TO MATCH ADJACENT SURFACES (UNO).

1.

2.

3.

4.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

17.

18.

19.

20.

21.

22.

23.

24.

1.

GENERAL

REFER TO INTERIOR PARTITION TYPES, PLANS, AND SPECIFICATIONS.

REFER TO FLOOR PLANS FOR FIRE-RATED AND/OR SMOKE PARTITION / BARRIER LOCATIONS.

AT RATED ASSEMBLIES, THE CONTRACTOR IS TO VERIFY THE GYP. BD. TYPE AND MANUFACTURER BASED ON THE WRITTEN DESCRIPTIONS FOR THE APPROPRIATE LISTED ASSEMBLY RATING SPECIFICATIONS.

CONTRACTOR TO PROVIDE ALL ADDITIONAL FRAMING AS REQUIRED FOR ALL OPENINGS AND SUPPLEMENTAL

FRAMING ABOVE PARTITIONS.

ALL WORK

ALL INTERIOR PARTITIONS SHALL BE TYPE M4.0 (UNO).

ALL INTERIOR PARTITIONS TO RECEIVE SOUND ATTENUATION INSULATION (UNO).

GYP. BD. REQUIREMENTS:

- ALL GYP. BD. TO BE 5/8" TYPE "X" (UNO).

- PROVIDE 5/8" TYPE "X" MOISTURE AND MOLD RESISTANT GYP. BD. AT ALL LOCATIONS WHERE WATER

PRODUCING DEVICES MAY BE PRESENT OR SPLASHED ONTO THE WALL SURFACE (I.E. LAVATORIES, WATER CLOSETS, HOSE BIBS, ETC.). EXTEND GYP. BD., A MINIMUM OF 4'-0' IN ALL DIRECTIONS FROM CENTER OF

DEVICE.

- PROVIDE 5/8" TYPE "X" MOISTURE AND MOLD RESISTANT GYP. BD. AT INTERIOR BOUNDARY AT EXTERIOR

WALL, INCLUDING COLUMN FURROUTS THAT ARE INTEGRATED INTO THE EXTERIOR WALL.

- PROVIDE TYPE "X" IMPACT RESISTANT GYP. BD. 4'-0" H AT ALL WALLS IN PATIENT ROOMS, EQUIPMENT

ALCOVES, AND ADDITIONAL LOCATIONS AS NOTED ON THE DRAWINGS.

- PROVIDE TILE BACKER BOARD AT ALL AREAS TO RECEIVE TILE FINISHES.

ALL PARTITIONS AROUND TR’S SHALL EXTEND FROM THE FLOOR SLAB AND SEAL TO THE UNDERSIDE OF THE STRUCTURE/DECK ABOVE WITHOUT ANY OPENINGS NOT FILLED WITH DUCTWORK, PIPES, AND CONDUITS.

CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, INFILL ANY OPENINGS, AND EXTEND PARTITIONS TO STRUCTURE AS REQUIRED. THE PARTITIONS SHALL, AT A MINIMUM, MEET THE M4.0 PARTITION TYPE.

ALL FIRE AND/OR SMOKE PARTITIONS / BARRIER SHALL EXTEND FROM FLOOR SLAB TO THE UNDERSIDE OF THE STRUCTURE - DECK ABOVE. ALL PENETRATIONS SHALL BE SEALED AND PROTECTED WITH FIRE-RATED

ASSEMBLIES TO MAINTAIN THE INTEGRITY OF THE PARTITION / BARRIER.

COSMETIC FURR-OUT AND WING WALLS (NOT INTEGRATED INTO EXTERIOR WALL) MAY TERMINATE 6" ABOVE ADJACENT CEILING. CAP TOP OF WALLS WITH GYP. BD. SUCH THAT FURR-OUT AND WING WALLS DOES NOT CREATE A BREACH IN THE ADJACENT WALL WHICH EXTENDS TO THE UNDERSIDE OF ROOF / FLOOR DECK ABOVE.

ALL FIRE AND OR SMOKE PARTITIONS / BARRIERS ARE TO ABUT THE EXTERIOR GYP. BD. SHEATHING.

FIRE AND/OR SMOKE PARTITION / BARRIER IDENTIFICATION:

- IDENTIFY PARTITIONS ABOVE ACCESSIBLE CEILINGS ON BOTH SIDES OF PARTITION, EXCEPT WITHIN SHAFTS, IN RED 3" HIGH STENCILED BLOCK LETTERING.

- STENCIL MESSAGE SIMILAR TO: "SMOKE PARTITION" OR "1 HOUR FIRE/SMOKE BARRIER"

- LOCATE MESSAGE NOT MORE THAN 10'-0" OC ON CORRIDOR SIDES OF PARTITIONS, WITH AT LEAST ONE

MESSAGE PER ROOM ON ROOM SIDE OF PARTITIONS, AND WITHIN 15'-0" OF THE END OF EACH WALL.

- USE SEMI-GLOSS PAINT.

WHERE RATED PARTITIONS / BARRIERS INTERSECT ONE OF LESSER RATING, THEIR LAYERS OF GYP. BD. SHALL BE CONTINUOUS THROUGH THE WALL OF LESSER RATING. SEAL ALL PENETRATIONS WITH APPROVED LISTED

ASSEMBLIES. THE FOLLOWING PRIORITIES SHALL BE OBSERVED:

- PRIORITY 1 - 3 HOUR FIRE WALL

- PRIORITY 2 - 2 HOUR FIRE WALL

- PRIORITY 3 - 2 HOUR FIRE / SMOKE

- PRIORITY 4 - 2 HOUR FIRE / SHAFT BARRIER

- PRIORITY 5 - 1 HOUR FIRE / SMOKE

- PRIORITY 6 - 1 HOUR SMOKE BARRIER

- PRIORITY 7 - 1 HOUR FIRE / SHAFT BARRIER

- PRIORITY 8 - NON-RATED SMOKETIGHT PARTITIONS

- PRIORITY 9 - NON-RATED PARTITIONS

STAGGER ALL GYP. BD. JOINTS ON OPPOSITE SIDES OF PARTITIONS AS FOLLOWS:

- VERTICAL JOINTS OFFSET 16" HORIZONTALLY.

- HORIZONTAL JOINTS OFFSET 24" VERTICALLY.

CONTROL JOINTS SHALL BE INSTALLED AT ALL CONSTRUCTION CHANGES WITHIN A PLANE OF A PARTITION OR CEILING. AT PARTITION RUNS THAT EXCEED 30'-0" IN LENGTH, CEILING DIMENSIONS THAT EXCEED 50'-0" IN EITHER DIRECTION WITH PERIMETER RELIEF AND 30'-0" WITHOUT, AT WINGS OF "L", "U", AND "T" SHAPED CEILING AREAS, AT BUILDING EXPANSION OR CONTROL JOINTS. CONTROL JOINTS SHALL BE INSTALLED AT EACH DOOR FROM OUTSIDE CORNER OF THE TOP OF DOOR JAMB TO ABOVE CEILING. REFER TO PUBLISHED CONTROL JOINT

DETAILS IN GA 600 FIRE RESISTANCE DEIGN MANUAL.

CONTRACTOR SHALL PROVIDE ADDITIONAL MATERIALS TO MAINTAIN THE APPROPRIATE FIRE RATING WHERE CONTROL JOINTS ARE LOCATED IN FIRE-RATED PARTITIONS / BARRIERS. INSTALLATION SHALL BE PER THE DETAILS SHOWN IN THE LATEST PUBLICATION OF THE USG CONSTRUCTION HANDBOOK, GYPSUM ASSOCIATION

PUBLICATION OR UNDERWRITERS LABORATORY FIRE RESISTANCE DIRECTORY.

ENSURE THAT THE GYP. BD. WALL PANELS ARE NOT OFFSET FROM THE SUBFLOOR (AT ALL CONDITIONS) OR THE

STRUCTURE ABOVE (IF REQUIRING SOUND ATTENUATION INSULATION) GREATER THAN 1/2".

ISOLATE DISSIMILAR METALS.

INSTALL ACOUSTICAL GASKETS AT FLOOR AND CEILING TRACK LOCATIONS.

SEAL ALL PENETRATIONS IN WALLS AS REQUIRED BY ASTM C919.

PROVIDE FIRE SAFING INSULATION AS REQUIRED TO MAINTAIN THE INTEGRITY OF FIRE-RATED PARTITIONS.

ALL VERTICAL PIPING AND COLUMNS EXPOSED IN ROOMS SHALL BE FURRED-OUT AND FINISHED TO MATCH ADJACENT WALLS (UNO). EXCEPTIONS: ELEC. CLOSETS, TELE. CLOSETS, AND MECHANICAL CLOSETS.

WHERE HVAC OR OTHER MECHANICAL, PLUMBING, ELECTRICAL ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND/OR ACOUSTICAL ISOLATION OF

SPACES WITH APPROPRIATE FIRE STOP MATERIAL.

PROVIDE AND INSTALL ANY STIFFENERS, BRACING, BACK-UP PLATES AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL FLOOR MOUNTED OR SUSPENDED MECHANICAL, OR ELECTRICAL ITEMS.

PROVIDE CONTINUOUS STIFFENER CHANNELS AT 4'-0" MAXIMUM VERTICAL SPACING, TYPICAL. ALSO PROVIDE AT MIDPOINT BETWEEN BOTTOM OF STRUCTURE AND HEAD OF INTERIOR WINDOWS AND DOORS AS WELL AS HINGE MIDPOINT AT DOORS. IF DOOR OPENING IS OVER 4'-0" LONG, PROVIDE STIFFENER CHANNELS AT ALL HINGE

POINTS FOR MINIMUM OF 2 STUD SPACES HORIZONTALLY.

AT ALL INTERSECTIONS WITH CEILINGS, PROVIDE METAL STUD FIRE BACKING AT NO GREATER THAN 8'-0" APART

AND AS REQUIRED BY THE FIRE RATED ASSEMBLY.

WHERE COLUMN FURRING STUDS EXCEED THE MANUFACTURER'S RECOMMENDED LIMITING HEIGHT, STUDS

SHALL BE BRACED.

DO NOT TRANSFER DEFLECTION FROM STRUCTURAL BUILDING MEMBERS TO STUDS. CONTRACTOR TO PROVIDE

EITHER OF THE FOLLOWING:

- MAINTAIN CLEARANCE UNDER STRUCTURAL BUILDING MEMBERS TO AVOID DEFLECTION TRANSFER TO

STUDS. PROVIDE EXTENDED LEG CEILING RUNNERS.

- PROVIDE DEFLECTION AND BRIDGING CLIPS.

RENOVATION

MAINTAIN FIRE / SMOKE RATINGS OF EXISTING PARTITIONS AND BARRIERS.

DIMENSIONS

1.

2.

3.

4.

1.

2.

3.

4.

5.

1.

2.

GENERAL

DRAWING SCALES INDICATED ARE FOR

REFERENCE ONLY. WRITTEN DIMENSIONS

SHALL GOVERN.

FIELD VERIFY ALL DIMENSIONS BEFORE

PROCEEDING WITH WORK.

IF DIMENSIONS ARE IN QUESTIONS OR THERE IS

A VARIATION OF +/- 1" FROM THE NOTED

DIMENSION, CONTACT ARCHITECT BEFORE

PROCEEDING WITH CONSTRUCTION.

REFER TO STANDARD MOUNTING HEIGHTS FOR

DIMENSIONS REGARDING PLACEMENT OF

PLUMBING FIXTURES AND PLUMBING FIXTURE

ACCESSORIES.

ALL WORK

DIMENSIONS FOR NEW CONSTRUCTION:

- CENTERLINE OF THE COLUMN

- TO THE EDGE OF STUD IN NEW PARTITIONS

- TO THE FACE OF CONCRETE/MASONRY

WALLS

- TO FINISHED FACE OF EXTERIOR WALLS.

(DIMENSIONS OF FINISHES ARE BASED ON

NOMINAL DIMENSIONS AND MAY VARY BY

MANUFACTURER. REFER TO WALL

SECTIONS.)

DOOR OPENINGS SHALL BE 4" (TYP) FROM THE

PERPENDICULAR WALL OR HINGE SIDE (UNO).

ALLOW FOR PROTRUDING HARDWARE.

ELEMENTS THAT APPEAR TO ALIGN ON

DRAWINGS ARE INTENDED TO ALIGN AND SHALL

BE MADE TO ALIGN (UNO).

ALIGN FINISHED FACE OF CONTINUOUS

PARTITIONS THAT CHANGE PARTITION TYPES

ALONG A STRAIGHT RUN.

CJ = GYPSUM BOARD CONTROL JOINT. REFER

TO SPEC 092900 FOR ADDITIONAL

REQUIREMENTS.

RENOVATION

DIMENSIONS OF EXISTING CONSTRUCTION ARE

TO THE CENTERLINE OF THE COLUMN AND THE

FACE OF EXISTING PARTITIONS.

WHERE INFILLING AN OPENING IN AN EXISTING

PARTITION, BOTH FACES OF THE INFILL SHALL

ALIGN WITH THE EXISTING.

RCP GENERAL NOTES

1.

2.

3.

4.

5.

1.

2.

3.

4.

5.

6.

7.

8.

9.

1.

2.

3.

4.

5.

6.

GENERAL

CONTRACTOR IS TO REVIEW CEILING LAYOUT

AND NOTIFY ARCHITECT OF ANY CONFLICTS

BEFORE PROCEEDING WITH CONSTRUCTION.

COORDINATE WITH MECHANICAL AND

ELECTRICAL DRAWINGS FOR CEILING MOUNTED

DEVICES.

COORDINATE WITH MECHANICAL, PLUMBING,

AND ELECTRICAL FOR ALL ABOVE CEILING

WORK TO MEET CEILING HEIGHTS.

REFER TO ROOM FINISH SCHEDULE FOR

CEILING MATERIALS.

REPLACE CEILING TILES AT THE END OF EACH

SHIFT IN WORK AREAS OUTSIDE OF A RATED

CONSTRUCTION BARRIER. IF THE TILES CANNOT

BE REPLACED, THE SPRINKLER SYSTEM MAY BE

CONSIDERED OUT OF SERVICE IN THESE AREAS

AND A 1-HOUR FIRE RATED SEPARATION WILL

BE REQUIRED BETWEEN THE CONSTRUCTION

AREA AND THE OCCUPIED PORTIONS OF THE

BUILDING.

ALL WORK

LIGHTS, DIFFUSERS, EXIT SIGNAGE, SPRINKLER

HEADS, AND SMOKE DETECTORS SHALL BE

CENTERED IN THE CEILING TILE.

EXIT SIGNAGE TO BE CENTERED OVER DOORS

(UNO).

CENTER CEILING GRID IN BOTH DIRECTIONS OF

THE SPACE (UNO).

ACCESS PANELS ARE NOT PERMITTED IN

SOFFITS. CHECK ALL VALVES, FIRE DAMPERS,

REHEAT BOXES, ETC. FOR ACCESS POINTS.

ARRANGE FIRE AND SMOKE DAMPERS FROM

NON-CORRIDOR SIDE.

THE CONTRACTOR SHALL VERIFY THAT ACCESS

PANELS OF APPROPRIATE SIZE AND TYPE ARE

INSTALLED IN NON-ACCESSIBLE TYPE CEILINGS

WHERE ACCESS, SERVICE, OR ADJUSTMENT TO

MECHANICAL, PLUMBING, ELECTRICAL ITEMS

MAY BE REQUIRED.

PAINT CUT EDGES OF ACT TO MATCH CEILING

TILE WHERE EXPOSED TO VIEW.

PAINT ALL INTERIOR SURFACES OF AIR DUCTS

AND CONVECTOR / BASEBOARD HEATING

CABINETS THAT ARE VISIBLE THROUGH GRILLES

AND LOUVERS WITH (1) ONE COAT OF FLAT

BLACK PAINT FOR 1'-6" MINIMUM OR BEYOND

LINE OF SIGHT, WHICHEVER IS GREATER.

HANG SUSPENSION SYSTEM INDEPENDENTLY

OF WALLS, COLUMNS, DUCTS, PIPES, AND

CONDUIT.

PROVIDE METAL BACKING AND/OR BRACING AS

REQUIRED FOR LIGHT FIXTURES EXCEEDING

50LBS IN WEIGHT OR WEIGHING MORE THAN

THE RATED LOAD CAPACITY OF THE OUTLET

BOX ON WHICH THE FIXTURE WILL BE MOUNTED.

REFER TO NFPA 70 NATIONAL ELECTRICAL CODE

CHAPTER 3.

RENOVATION

REPAIR EXISTING CEILING GRID AND TILES AS

NEEDED AT CONSTRUCTION TIE-INS.

WHERE NEW CEILINGS ARE INDICATED, REMOVE

ALL EXISTING CEILINGS AND ACCESSORIES TO

ALLOW FOR PROPER INSTALLATION OF NEW

CEILINGS. PATCH / REPAIR AS NEEDED.

IN TELECOM ROOMS, CONTRACTOR IS

RESPONSIBLE FOR REMOVING ALL CEILINGS TO

EXPOSED UNDERSIDE OF STRUCTURE UNO.

EXTEND/TRIM EXISTING CEILING GRIDS TO NEW

PARTITION.

PROVIDE NEW ANGLE MOULDING TO RECEIVE

CEILING SYSTEM ALONG NEW PARTITION. MITER

AND ATTACH TO EXISTING ANGLE MOULDING AS

REQUIRED.

CUT NEW CEILING TILE TO FILL ALL OPENING IN

SPACE. REPLACE ANY CEILING TILES DAMAGED

DURING CONSTRUCTION.

DOOR GENERAL NOTES

1.

2.

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

1.

GENERAL

REFER TO THE DOOR AND HARDWARE

SCHEDULE, ELECTRICAL AND LOW VOLTAGE

DRAWINGS, AND SPECIFICATIONS FOR

ADDITIONAL INFORMATION.

FIELD VERIFY EXISTING CONDITIONS WHERE

NEW HARDWARE COMPONENTS ARE

SCHEDULED ON EXISTING DOORS OR WHERE

MODIFICATION TO EXISTING DOOR HARDWARE

ARE REQUIRED. COORDINATE INSTALLATION OF

DOOR HARDWARE TO SUIT EXISTING

CONDITIONS AND TO PROVIDE FOR PROPER

OPERATION.

ALL WORK

ALL NEW DOOR OPENINGS LOCATED 4" FROM

ADJACENT WALL AT HINGE SIDE, UNO.

PROVIDE FINISHED DOOR VERTICAL AND TOP

EDGES SAME AS DOOR FACE FINISH.

ALL DOORS SHALL HAVE STANDARD 5/8"

UNDERCUT (UNO).

ALL CROSS-CORRIDOR DOORS SHALL BE

NARROW LITE WHICH INCLUDE VIEW LITES THAT

MEET ANSI / ADA REQUIREMENTS (UNO).

ALL FRAMES SHALL BE FULLY WELDED. KNOCK-

DOWN FRAMES ARE NOT PERMITTED.

AT ALL EXTERIOR OPENINGS, PROVIDE FRAMES

WITH FOAM-IN-PLACE INSULATION.

SEAL AROUND THE FULL PERIMETER OF THE

DOOR FRAME .

TEXTURED (KNURLED) SURFACES REQUIRED ON

DOOR HANDLES LEADING TO HAZARDOUS

ROOMS.

USE WALL MOUNTED DOOR STOPS WHERE

POSSIBLE. OTHERWISE, USE HEAVY DUTY

CONCEALED OVERHEAD DOOR STOPS.

PROVIDE HEAVY DUTY HINGES ON DOORS OVER

3'-6" W.

COORDINATE WITH COR/VA FOR FINAL KEYING

REQUIREMENTS.

PROVIDE SMOKE LABELED GASKETING ON ALL

FIRE / SMOKE RATED DOORS.

PROVIDE ALUMINUM THRESHOLD,

WEATHERSTRIPPING, DOOR BOTTOM, AND

RAINDRIP AT ALL EXTERIOR DOORS.

PROVIDE CONDUIT TO THE TOP OF DOOR

HEADERS IN CENTER FOR DOUBLE DOORS AND

TO NON-HINGE SIDE FOR SINGLE DOORS

SCHEDULED TO RECEIVE ELECTRONIC

HARDWARE.

ELECTRIC STRIKES SHALL BE FAIL SECURE

(UNO).

ALL EXTERIOR DOORS TO BE INSULATED.

RENOVATION

COORDINATE CONDUITS AND/OR WIRING

REQUIREMENTS FOR DOORS / FRAMES /

HARDWARE DURING FRAME INSTALLATION FOR

ELECTRICAL CONNECTIONS FOR LOCKS,

STRIKES, ETC. TO ENSURE PROPER DOOR

OPERATION.

Engineers Architects Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/6

/2

5:

:0

PM

C :\U se rs

\a pu lle n\

D oc um en ts \M

S_

-1

-V A

D ub lin E

H R

M _G

EN

_R

_a pu lle nV D

XT

7.

rv t

A-001

ARCHITECTURAL SYMBOLS,

ABBREVIATIONS AND GENERAL NOTES

1 56ANP

EHRM INFRASTRUCTURE

UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027 NOVEMBER 8, 2024

100% BID DOCUMENTS

557-22-70022-192

VARIOUS

DJR

ARCHITECTURAL SYMBOL LEGENDGENERAL NOTES

DEMOLITION NOTES

EQUIPMENT GENERAL NOTES

WALL TYPES GENERAL NOTES

5070L

IC

E N

S E D A RC H I T ECT

DA

V ID J . REICHARD

NOR T H CA RO L I NA

CR

ENVIRONMENT

MGMT HK

CLOSET

102-1

CORRIDOR

C11-1

1.2

101-1

1.2

3.1

3.4 2.1

3.5

4.1

8' -6

/2

15'-1"

CENTRALIZED

STAFF FAC

MENS TLT

103-1

126 SF

101-1

TR

5.7

5.14.2

5.5

ENVIRONMENT

MGMT HK

CLOSET

102-1

CORRIDOR

C11-1

2.1

3.1

4.1

HUMAN

RESOURCES

OFFICE

101-1

CENTRALIZED

STAFF FAC

MENS TLT

103-1

15'-1"

8' -6

/2

ENVIRONMENT

MGMT HK

CLOSET

102-1

CORRIDOR

C11-1

6.1

CENTRALIZED

STAFF FAC

MENS TLT

103-1

CEILING NOTES:

8'-0" A.F.F. EXISTING ACT

9'-2" A.F.F. TO PLASTER ABOVE CEILING

11'-6" A.F.F. TO BOTTOM OF CONCRETE ABOVE CEILING

10'-6" A.F.F. TO BOTTOM OF BEAM ABOVE CEILING

A.F.F.8' - 0"

HUMAN

RESOURCES

OFFICE

101-1

ENVIRONMENT

MGMT HK

CLOSET

102-1

CORRIDOR

C11-1

6.1

6.26.3

6.4

CENTRALIZED

STAFF FAC

MENS TLT

103-1

101-1

TR

Engineers Architects

# DEMOLITION KEY NOTES:

# NEW KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/6

/2

:5 6:

P

M C

:\U se rs \a pu lle n\ D oc um en ts

\A _2

2-

2-

VA

D ub lin E

H R

M -B ld g

1_ R

_a pu lle nV D

XT

7.

rv t

01.A-411

BUILDING 1, LEVEL A, TELECOM ROOM

101-1 PLANS

2 56ANP

EHRM INFRASTRUCTURE

UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027 NOVEMBER 8, 2024

100% BID DOCUMENTS

557-22-70022-192

DJR

0 2 4 8

NORTH

1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED

AC GRADE PLYWOOD BACK BOARDS IN TELECOM

ROOMS. PLYWOOD SHALL BE MOUNTED WITH

A-SIDE OUT. PAINT PLYWOOD BACK BOARDS P-2.

2.1 NEW FLOORING, INCLUDING UNDERLAYMENT,

AND RUBBER WALL BASE, SEE SPECS AND ROOM

FINISH SCHEDULE.

3.1 NEW DOOR & FRAME IN EXISTING MASONRY

WALL, SEE DOOR SCHEDULE.

3.4 NEW CARD READER, SEE ELECTRICAL

DRAWINGS.

3.5 APPLY SAFETY WINDOW FILM TO INTERIOR FACE

OF GLAZING, AND INSTALL AN EXPANDED METAL

SCREEN AT EXISTING WINDOW.

4.1 NEW ROOM SIGN, SEE SHEET A-602.

4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN

AGENT SIGN, SEE SHEET A-602.

5.1 INSTALL NEW SURFACE MOUNTED FIRE

EXTINGUISHER CABINET.

5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO

MATCH EXISTING.

5.7 FLOOR TRANSITION

6.1 EXPOSED STRUCTURE

6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL

DRAWINGS.

6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.

6.4 WALL MOUNTED HVAC EQUIPMENT, SEE

MECHANICAL DRAWINGS.

Scale: 1/4" = 1'-0"

TELECOM ROOM FLOOR PLAN

Scale: 1/4" = 1'-0"

OFFICE DEMOLITION FLOOR PLAN 0 2 4 8

NORTH

Scale: 1/4" = 1'-0"

OFFICE DEMOLITION REFLECTED CEILING PLAN

0 2 4 8

NORTH

0 2 4 8

NORTH

Scale: 1/4" = 1'-0"

TELECOM ROOM REFLECTED CEILING PLAN

2.1 REMOVE EXISTING FLOOR FINISH AND BASE. PATCH

ALL HOLES AND LEVEL UNEVEN SUBFLOOR.

3.1 REMOVE EXISTING DOOR & FRAME, PREPARE

ROUGH OPENING AS REQUIRED FOR NEW DOOR.

4.1 REMOVE EXISTING SIGNAGE AND TURN OVER TO

VA.

6.1 REMOVE EXISTING ACT CEILING, INCLUDING

ELECTRICAL AND MECHANICAL FIXTURES. SEE

ELECTRICAL AND MECHANICAL DRAWINGS.

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

5070L

IC

E N

S E D A RC H I T ECT

DA

V ID J . REICHARD

NOR T H CA RO L I NA

PIPE SPACE

206-1

CONSULT MGMT

208A-1

FEE SVC

OFFICE

208-1

CORRIDOR

CR22-1

4.1

3.1

IRM

207-1

2.1

CORRIDOR

CR21-1

PIPE SPACE

206-1

CONSULT MGMT

208A-1

FEE SVC

OFFICE

208-1

CR22-1

CORRIDOR

1.2

207-1

1.2

3.13.4

2.1

4.1

8'-8 1/2"

9' -2

/2

80 SF

207-1

TR

5.7

5.5

CORRIDOR

CR21-1

5.1

4.2

PIPE SPACE

206-1

CONSULT MGMT

208A-1

FEE SVC

OFFICE

208-1

CORRIDOR

CR22-1

6.4 IRM

207-1

CEILING NOTES:

11'-6" A.F.F. BOTTOM ON CONCRETE

10'-4" A.F.F. BOTTOM OF BEAM

6.6

6.8

CORRIDOR

CR21-1

6.9

PIPE SPACE

206-1

CONSULT MGMT

208A-1

FEE SVC

OFFICE

208-1

CORRIDOR

CR22-1

6.1

6.2

6.3

6.4

CORRIDOR

CR21-1

207-1

TR

Engineers Architects

# DEMOLITION KEY NOTES:

# NEW KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/6

/2

:5 6:

P

M C

:\U se rs \a pu lle n\ D oc um en ts

\A _2

2-

2-

VA

D ub lin E

H R

M -B ld g

1_ R

_a pu lle nV D

XT

7.

rv t

01.A-421

BUILDING 1, LEVEL B, TELECOM ROOM

207-1 PLANS

3 56ANP

EHRM INFRASTRUCTURE

UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027 NOVEMBER 8, 2024

100% BID DOCUMENTS

557-22-70022-192

DJR

0 2 4 8

NORTH

0 2 4 8

NORTH

0 2 4 8

NORTH

0 2 4 8

NORTH

Scale: 1/4" = 1'-0"

IRM ROOM DEMOLITION FLOOR PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM FLOOR PLAN

Scale: 1/4" = 1'-0"

IRM ROOM DEMOLITION REFLECTED CEILING PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM REFLECTED CEILING PLAN

2.1 REMOVE EXISTING FLOOR FINISH AND BASE.

PATCH ALL HOLES AND LEVEL UNEVEN SUBFLOOR.

3.1 REMOVE EXISTING DOOR & FRAME, PREPARE

ROUGH OPENING AS REQUIRED FOR NEW DOOR.

4.1 REMOVE EXISTING SIGNAGE AND TURN OVER TO

VA.

6.4 EXISTING EXPOSED STRUCTURE.

6.6 REMOVE EXISTING LIGHTING, TYP. SEE

ELECTRICAL DRAWINGS.

6.8 DEMOLISH WALL MOUNTED HVAC EQUIPMENT, SEE

MECHANICAL DRAWINGS.

6.9 DEMOLISH EXISTING CABLE TRAY, SEE ELECTRICAL

DRAWINGS.

1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED AC

GRADE PLYWOOD BACK BOARDS IN TELECOM

ROOMS. PLYWOOD SHALL BE MOUNTED WITH

A-SIDE OUT. PAINT PLYWOOD BACK BOARDS P-2.

2.1 NEW FLOORING, INCLUDING UNDERLAYMENT, AND

RUBBER WALL BASE, SEE SPECS AND ROOM

FINISH SCHEDULE.

3.1 NEW DOOR & FRAME IN EXISTING MASONRY WALL,

SEE DOOR SCHEDULE.

3.4 NEW CARD READER, SEE ELECTRICAL DRAWINGS.

4.1 NEW ROOM SIGN, SEE SHEET A-602.

4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN

AGENT SIGN, SEE SHEET A-602.

5.1 INSTALL NEW SURFACE MOUNTED FIRE

EXTINGUISHER CABINET.

5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO

MATCH EXISTING.

5.7 FLOOR TRANSITION

6.1 EXPOSED STRUCTURE

6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL

DRAWINGS.

6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.

6.4 WALL MOUNTED HVAC EQUIPMENT, SEE

MECHANICAL DRAWINGS.

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

5070L

IC

E N

S E D A RC H I T ECT

DA

V ID J . REICHARD

NOR T H CA RO L I NA

STORAGE

BM123A-2

REFRIGERATION

COMPRESSOR

RM

BM121-2

STORAGE

BM123-2

CORRIDOR

CRB1-2

2.12.2

3.1

2.1

1.1

4.2

IT

BM123B-2

6'-8"

STORAGE

BM123A-2

REFRIGERATION

COMPRESSOR

RM

BM121-2

STORAGE

BM123-2

CORRIDOR

CRB1-2

1.2

1.2

3.1

3.4

4.1

1.12.25.4

2.1

4.2

5.1

11'-5"

'-8

/2

118 SF

BM123B-2

TR

BM123B-2

5.6

5.5

M4.0

1.2

STORAGE

BM123A-2

REFRIGERATION

COMPRESSOR

RM

BM121-2

STORAGE

BM123-2

CORRIDOR

CRB1-2

6.2

6.3

6.4

6.5

BM123B-2

TR

STORAGE

BM123A-2

REFRIGERATION

COMPRESSOR

RM

BM121-2

STORAGE

BM123-2

CORRIDOR

CRB1-2

CEILING NOTES:

11'-7" A.F.F. BOTTOM OF CONCRETE

10'-7" A.F.F. BOTTOM OF BEAM

6.4

6.46.6

6.6

6.8

6.9

IT

BM123B-2

Engineers Architects

# DEMOLITION KEY NOTES:

# NEW KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/6

/2

:5 0:

P

M C

:\U se rs \a pu lle n\ D oc um en ts

\A _2

2-

2-

VA

D ub lin E

H R

M -B ld g

2_ R

_a pu lle nV D

XT

7.

rv t

02.A-401

BUILDING 2, LEVEL C, TELECOM ROOM

BM123B-2 PLANS

4 56ANP

EHRM INFRASTRUCTURE

UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027 NOVEMBER 8, 2024

100% BID DOCUMENTS

557-22-70022-192

DJR

1.1 NEW WALL, TYP. SEE A-506.

1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED AC

GRADE PLYWOOD BACK BOARDS IN TELECOM

ROOMS. PLYWOOD SHALL BE MOUNTED WITH

A-SIDE OUT. PAINT PLYWOOD BACK BOARDS P-2.

2.1 NEW FLOORING, INCLUDING UNDERLAYMENT, AND

RUBBER WALL BASE, SEE SPECS AND ROOM

FINISH SCHEDULE.

2.2 PATCH FLOORING TO MATCH EXISTING.

3.1 NEW DOOR & FRAME IN EXISTING MASONRY WALL,

SEE DOOR SCHEDULE.

3.4 NEW CARD READER, SEE ELECTRICAL DRAWINGS.

4.1 NEW ROOM SIGN, SEE SHEET A-602.

4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN

AGENT SIGN, SEE SHEET A-602.

5.1 INSTALL NEW SURFACE MOUNTED FIRE

EXTINGUISHER CABINET.

5.4 NEW PAINT AND RUBBER WALL BASE TO MATCH

EXISTING.

5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO

MATCH EXISTING.

5.6 FLOOR TRANSITION AT STATIC DISSIPATIVE TILE

TO EXTEND FROM UNDERSIDE OF TELECOM ROOM

TO ADJACENT ROOM.

6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL

DRAWINGS.

6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.

6.4 WALL MOUNTED HVAC EQUIPMENT, SEE

MECHANICAL DRAWINGS.

6.5 COORDINATE EXISTING CEILING WITH NEW

PARTITION.

0 2 4 8 NORTH

0 2 4 8 NORTH

0 2 4 8 NORTH

0 2 4 8 NORTH Scale: 1/4" = 1'-0"

IT & STORAGE DEMOLITION FLOOR PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM FLOOR PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM REFLECTED CEILING PLAN

Scale: 1/4" = 1'-0"

IT & STORAGE DEMOLITION REFLECTED CEILING PLAN

1.1 DEMOLISH EXISTING WALL.

2.1 REMOVE EXISTING FLOOR FINISH AND BASE.

PATCH ALL HOLES AND LEVEL UNEVEN SUBFLOOR.

2.2 EXISTING FLOOR FINISH TO REMAIN.

3.1 REMOVE EXISTING DOOR & FRAME, PREPARE

ROUGH OPENING AS REQUIRED FOR NEW DOOR.

4.2 REMOVE EXISTING SIGNAGE. RETAIN FOR REUSE.

6.4 EXISTING EXPOSED STRUCTURE.

6.6 REMOVE EXISTING LIGHTING, TYP. SEE

ELECTRICAL DRAWINGS.

6.8 DEMOLISH WALL MOUNTED HVAC EQUIPMENT, SEE

MECHANICAL DRAWINGS.

6.9 DEMOLISH EXISTING CABLE TRAY, SEE ELECTRICAL

DRAWINGS.

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

5070L

IC

E N

S E D A RC H I T ECT

DA

V ID J . REICHARD

NOR T H CA RO L I NA

ES

2.2

2.1

1.1

3.3

2.2

3.2

4.1

2.1

TR

104-2

102C-2

NOURISHMENT

PREP

102B-3

KITCHEN

CR-14-2

SERVICE

CORRIDOR

1.2

1.2

1.1 3.1

3.4 4.1

2.1

2.2

4.2

5.1

166 SF

104-2

TR

104-2 5.6

5.5

C6.0

C6.0

1.12.2

1.2

C6.0

102C-2

NOURISHMENT

PREP

102B-3

KITCHEN

5.45.4

5.4

5.5

CR-14-2

SERVICE

CORRIDOR

1.41.4

'-1

1"

11'-0"

5.3 5.3

6.4

A.F.F.8' - 0"

CEILING NOTES:

8'-0" A.F.F. EXISTING ACT

11'-7" A.F.F. BOTTOM OF CONCRETE

10'-7" A.F.F. BOTTOM OF BEAM

102C-2

NOURISHMENT

PREP

102B-3

KITCHEN

CR-14-2

SERVICE

CORRIDOR

6.8

6.7

6.7

6.9

6.2

6.1

6.2

6.3

6.46.5 104-2

TR

6.5

102C-2

NOURISHMENT

PREP

102B-3

KITCHEN

CR-14-2

SERVICE

CORRIDOR

Engineers Architects

# DEMOLITION KEY NOTES:

# NEW KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/6

/2

:5 0:

P

M C

:\U se rs \a pu lle n\ D oc um en ts

\A _2

2-

2-

VA

D ub lin E

H R

M -B ld g

2_ R

_a pu lle nV D

XT

7.

rv t

02.A-411

BUILDING 2, LEVEL A, TELECOM ROOM

104-2 PLANS

5 56ANP

EHRM INFRASTRUCTURE

UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027 NOVEMBER 8, 2024

100% BID DOCUMENTS

557-22-70022-192

DJR

Scale: 1/4" = 1'-0"

KITCHEN & TR DEMOLITION FLOOR PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM FLOOR PLAN

Scale: 1/4" = 1'-0"

KITCHEN & TR DEMOLITION REFLECTED CEILING PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM REFLECTED CEILING PLAN

1.1 DEMOLISH EXISTING WALL.

2.1 REMOVE EXISTING FLOOR FINISH AND BASE. PATCH

ALL HOLES AND LEVEL UNEVEN SUBFLOOR.

2.2 EXISTING FLOOR FINISH TO REMAIN.

3.2 REMOVE EXISTING DOOR & FRAME.

3.3 CREATE ROUGH OPENING FOR NEW DOOR.

4.1 REMOVE EXISTING SIGNAGE AND TURN OVER TO VA.

6.2 REMOVE EXISTING ACT CEILING, INCLUDING

ELECTRICAL, MECHANICAL, AND FIRE SUPPRESSION

FIXTURES. SEE ELECTRICAL AND MECHANICAL

DRAWINGS.

6.4 EXISTING EXPOSED STRUCTURE.

6.7 EXISTING CEILING TO REMAIN.

6.8 DEMOLISH WALL MOUNTED HVAC EQUIPMENT, SEE

MECHANICAL DRAWINGS.

6.9 DEMOLISH EXISTING CABLE TRAY, SEE ELECTRICAL

DRAWINGS.

0 2 4 8 NORTH

0 2 4 8 NORTH

0 2 4 8 NORTH

0 2 4 8 NORTH

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

1.1 NEW WALL, TYP. SEE A-506.

1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED AC

GRADE PLYWOOD BACK BOARDS IN TELECOM

ROOMS. PLYWOOD SHALL BE MOUNTED WITH A-SIDE

OUT. PAINT PLYWOOD BACK BOARDS P-2.

1.4 ALIGN WALLS

2.1 NEW FLOORING, INCLUDING UNDERLAYMENT, AND

RUBBER WALL BASE, SEE SPECS AND ROOM FINISH

SCHEDULE.

2.2 PATCH FLOORING TO MATCH EXISTING.

3.1 NEW DOOR & FRAME IN EXISTING MASONRY WALL,

SEE DOOR SCHEDULE.

3.4 NEW CARD READER, SEE ELECTRICAL DRAWINGS.

4.1 NEW ROOM SIGN, SEE SHEET A-602.

4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN

AGENT SIGN, SEE SHEET A-602.

5.1 INSTALL NEW SURFACE MOUNTED FIRE

EXTINGUISHER CABINET.

5.3 NEW CORNER GUARD.

5.4 NEW PAINT AND RUBBER WALL BASE TO MATCH

EXISTING.

5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO

MATCH EXISTING.

5.6 FLOOR TRANSITION AT STATIC DISSIPATIVE TILE TO

EXTEND FROM UNDERSIDE OF TELECOM ROOM TO

ADJACENT ROOM.

6.1 EXPOSED STRUCTURE

6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL

DRAWINGS.

6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.

6.4 WALL MOUNTED HVAC EQUIPMENT, SEE

MECHANICAL DRAWINGS.

6.5 COORDINATE EXISTING CEILING WITH NEW

PARTITION.

5070L

IC

E N

S E D A RC H I T ECT

DA

V ID J . REICHARD

NOR T H CA RO L I NA

ES

BILLING

212-2

OFFICE

212A-2

STORAGE

212B-2

209A-2

TR

3.1CORRIDOR

CR-21-2

2.1

BILLING

212-2

OFFICE

212A-2

STORAGE

212B-2

1.2

4.1

3.4

3.1

2.1

5.1

4.2

176 SF

209A-2

TR

209A-2

5.6

5.5

1.2

CORRIDOR

CR-21-2

7'-3"

'-4

BILLING

212-2OFFICE

212A-2

STORAGE

212B-2

6.4

209A-2

TR

CEILING NOTES:

11'-5" A.F.F. BOTTOM OF CONCRETE

10'-4" A.F.F. BOTTOM OF BEAM

6.5

CORRIDOR

CR-21-2

6.9

BILLING

212-2

OFFICE

212A-2

STORAGE

212B-2

6.2

6.3

6.4

209A-2

TR

CORRIDOR

CR-21-2

Engineers Architects

# DEMOLITION KEY NOTES:

# NEW KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/6

/2

:5 0:

P

M C

:\U se rs \a pu lle n\ D oc um en ts

\A _2

2-

2-

VA

D ub lin E

H R

M -B ld g

2_ R

_a pu lle nV D

XT

7.

rv t

02.A-421

BUILDING 2, LEVEL B, TELECOM ROOM

209A-2 PLANS

6 56ANP

EHRM INFRASTRUCTURE

UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027 NOVEMBER 8, 2024

100% BID DOCUMENTS

557-22-70022-192

DJR

Scale: 1/4" = 1'-0"

TELECOM ROOM DEMOLITION FLOOR PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM FLOOR PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM DEMOLITION REFLECTED CEILING PLAN

Scale: 1/4" = 1'-0"

TELECOM ROOM REFLECTED CEILING PLAN

2.1 REMOVE EXISTING FLOOR FINISH AND BASE.

PATCH ALL HOLES AND LEVEL UNEVEN

SUBFLOOR.

3.1 REMOVE EXISTING DOOR & FRAME, PREPARE

ROUGH OPENING AS REQUIRED FOR NEW DOOR.

6.4 EXISTING EXPOSED STRUCTURE.

6.5 REMOVE EXISTING ELECTRICAL, MECHANICAL &

FIRE SUPPRESSION FIXTURES. SEE ELECTRICAL

AND MECHANICAL DRAWINGS.

6.9 DEMOLISH EXISTING CABLE TRAY, SEE

ELECTRICAL DRAWINGS.

0 2 4 8 NORTH

0 2 4 8 NORTH

0 2 4 8 NORTH

0 2 4 8 NORTH

N

AREA OF WORK

KEY PLAN

SCALE: NO SCALE

1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED

AC GRADE PLYWOOD BACK BOARDS IN

TELECOM ROOMS. PLYWOOD SHALL BE

MOUNTED WITH A-SIDE OUT. PAINT PLYWOOD

BACK BOARDS P-2.

2.1 NEW FLOORING, INCLUDING UNDERLAYMENT,

AND RUBBER WALL BASE, SEE SPECS AND

ROOM FINISH SCHEDULE.

3.1 NEW DOOR & FRAME IN EXISTING MASONRY

WALL, SEE DOOR SCHEDULE.

3.4 NEW CARD READER, SEE ELECTRICAL

DRAWINGS.

4.1 NEW ROOM SIGN, SEE SHEET A-602.

4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN

AGENT SIGN, SEE SHEET A-602.

5.1 INSTALL NEW SURFACE MOUNTED FIRE

EXTINGUISHER CABINET.

5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO

MATCH EXISTING.

5.6 FLOOR TRANSITION AT STATIC DISSIPATIVE TILE

TO EXTEND FROM UNDERSIDE OF TELECOM

ROOM TO ADJACENT ROOM.

6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL

DRAWINGS.

6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.

6.4 WALL MOUNTED HVAC EQUIPMENT, SEE

MECHANICAL DRAWINGS.

5070L

IC

E N

S E D A RC H I T ECT

DA

V ID J . REICHARD

NOR T H CA RO L I NA

STORAGE

BM101-3

LAB STORAGE

BM102-3

CORRIDOR

CRB1-3

STAIR C-2

STB1-3

2.2

3.1

4.1

3.3

2.1

EXISTING FEC

5.9

9' -8

STORAGE

BM101-3

LAB STORAGE

BM102-3

CORRIDOR

CRB1-3

STAIR C-2

STB1-3

1.2

BM101-3

1.2

3.4

5.4

2.2 1.1

3.1

2.1

3.1

4.1

12'-11"

4.1

5.6

5.5

5.5

EXISTING FEC

8' -8

9'

-8

113 SF

TR

BM101A-3

M4.1

1.2

5.14

BM101A-3

5.1

4.2

5.5

STORAGE

BM101-3

LAB STORAGE

BM102-3

CORRIDOR

CRB1-3

STAIR C-2

STB1-3

6.1

CEILING NOTES:

9'-0" A.F.F. EXISTING 1X1 ACT

11'-6" A.F.F. BOTTOM OF CONCRETE

10'-8" A.F.F. BOTTOM OF BEAM

6.7

A.F.F.9' - 0"

6.11

7.2

STORAGE

BM101-3

LAB STORAGE

BM102-3

CORRIDOR

CRB1-3

STAIR C-2

STB1-3

6.1 6.2

6.3

6.4 6.5

TR

BM101A-3

6.6

Engineers Architects

# DEMOLITION KEY NOTES:

# NEW KEY NOTES:

Revisions: Date

Drawing Title

Approved

Project Title

Location

VA PROJECT NUMBER

Building Number

Drawing Number

Dwg of

VA FORM 08-6231

Office of Construction and Facilities Management

CONSULTANTS: PROJECT MANAGER

Date Checked Drawn

FULLY SPRINKLERED

ACG Project Number

Headquarters:

Apogee Consulting Group, P.A.

1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.

/6

/2

:4 9:

A

M C

:\U se rs \a pu lle n\ D oc um en ts

\A _2

2-

2-

VA

D ub lin E

H R

M -B ld g

3_ R

_a pu lle nV D

XT

7.

rv t

03.A-401

BUILDING 3, LEVEL C, TELECOM ROOM

BM101A-3 PLANS

7 56ANP

EHRM INFRASTRUCTURE

UPGRADES

CARL VINSON VA MEDICAL CENTER

1826 VETERANS BLVD

DUBLIN, GA 31027 NOVEMBER 8, 2024

100% BID DOCUMENTS

557-22-70022-192

DJR

1.1 NEW WALL, TYP. SEE A-506.

1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED

AC GRADE PLYWOOD BACK BOARDS IN

TELECOM ROOMS. PLYWOOD SHALL BE

MOUNTED WITH A-SIDE OUT. PAINT PLYWOOD

BACK BOARDS P-2.

2.1 NEW FLOORING, INCLUDING UNDERLAYMENT,

AND RUBBER WALL BASE, SEE SPECS AND

ROOM FINISH SCHEDULE.

2.2 PATCH FLOORING TO MATCH EXISTING.

3.1 NEW DOOR & FRAME IN EXISTING MASONRY

WALL, SEE DOOR SCHEDULE.

3.4 NEW CARD READER,…