This document is a set of architectural demolition and construction drawings for telecommunications room upgrades at the Carl Vinson VA Medical Center in Dublin, Georgia. The drawings, labeled as Volume 2 of 4, comprehensively detail demolition and reconstruction plans for telecommunications rooms across 13 different buildings within the medical center campus. The plans include floor and ceiling demolition layouts, specific room-by-room renovation instructions, and technical specifications for each telecom room, such as installing new fire-rated plywood backboards, flooring, doors, signage, electrical components, and HVAC equipment. The project involves systematic infrastructure improvements, with each building's telecom rooms receiving standardized upgrades to enhance communication infrastructure and meet specific technical requirements.
View the file
Other files for this federal contract opportunity
Show all 32
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
7' -0
5'-0"
VAN
ACCESSIBLE
LOADING AREA
SF
SF
EA
SE
MEN
T A
PP
RO
XIM
AT
EL
Y S
HO
WN
' E
XIS
TIN
G W
AT
ER
LI
NE
EA
SE
MEN
T
2.5" PLASTIC WITNESS POST
1/2" REBAR FOUND IN
CONCRETE MONUMENT
CONCRETE NAIL FOUND
Bldg 5 Gen
Bldg 4 Gen
Water Tower Gen
Bldg 8 Gen
Circuit 2 Gen
OBSERVATION MONITORING WELL
UP
UP
DEANE + STROLLO, LLC718 Virginia DriveOrlando, FL. 32803T: (407) 423-5355 F: (407) 422-5994
H
IL
LC
R
ES
T
PK
W
Y.
BE
LL
EV
UE
R D.
INDUSTRIAL BLVD.
INDUSTRIAL BLVD.
H
IL
LC
R
ES
T
PK
W
Y.
FAIRVIEW PARK HOSPITAL
FA
IR
VI
EW
P
AR
K
DR
IV
E
Bldg 27 Gen
F
F
F
F
F F
F
F
FF
F
F
SIGN
NE
FF
PL
AC
E
NE
FF
P
LA
CE
BE
LL
EV
UE
AV
EN
UE
AL
EX
AN
DE
R D
RIV
E
JO
HNSO
N ST
REE
T
PARKING
PARKING
PARKING
PARKING
PARKING
PARKING
METAL BLDGS.BLDG. 31
BLDG. 46
BLDG. 36
BLDG. 24
BLDG. 43
BLDG. 32
BLDG. 39
GAZEBO
BLDG. 68
BLDG. 67
BLDG. 21
LAKE LEISURE
AC
AC
PARKING
PARKING
BLDG. 34
BLDG. 35
STEPS
RAMP
PATIO
R
AM
P 1:
S
LO
PE
R
AM
P 1:
S
LO
PE
R
AM
P 1:
S
LO
PE
LA
N
D
IN
G
VAN VAN VAN VAN
RAMP
CONCRETE DITCH
CONCRETE
CONCRETE
CONCRETE
SLAB
SLAB
NEW PARKING
CTCT
AC
AC
AC
AC
OBSERVATION MONITORING WELL
BLDG. 17
BLDG.
BLDG. 47
BLDG. 41
BLDG
BLDG. 63
BLDG. 81
BLDG. 82
BLDG. 27
BLDG.
BLDG. 71BLDG. 28
BLDG. 66
CO
OL
IN
G
TO
W
ER
BLDG. 69
BLDG. 30
WATER TANK
BLDG. 5
BLDG. 3 BLDG. 1
BLDG. 9
BLDG. 13
BLDG. 11
BLDG. 2
BLDG. 40
BLDG. 4
BLDG. 6
BLDG. 8
BLDG. 10
BLDG. 12
BLDG. 85
BLDG. 14
BLDG. 86
BLDG. 25
BLDG. 26
BLDG. 29
BLDG. 15
BLDG. 19
GAZEBO
SUBSTATION
BLDG. 44
BLDG. 62
BLDG. 84
BLDG.
Bldg 2 Gen
FUEL
TANK
MRI
BLDG.29
ANNEX
New Water Tower Location
Bldg.10
New Chiller Plant
BLDG. 87
BLACKWOOD DRIVE
EX
IS
TIN
G
JO
HN
SO
N
ST
RE
ET
JOHNSON STREET
ALEXANDER DRIVE
BLACKWOOD DRIVE
TROJAKOWSKI AVENUE
EVANS AVENUE
TROJAKOWSKI AVENUE
EVANS AVENUE
CROWLEY AVENUE
CROWLEY AVENUE
VETERANS PARKWAY US HWY 80
VETERANS PARKWAY US HWY 80 VETERANS PARKWAY US HWY 80
JOHNSON STREET
BLACKWOOD DRIVE
AL
EX
AN
DE
R D
RIV
E
JOHNSON STREET
THOMAS LANE
THOMAS LANE
NORTHWEST DRIVE
JOHNSON STREET
EVANS AVENUE
TROJAKOWSKI AVENUE
NEW JO
HNSON STREET WEST
SHADED BUILDINGS REPRESENT
PROJECT SCOPE
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027
Engineers Architects Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
PROJECT SITE MAP PROJECT LOCATION MAP
/6
/2
9:
:1
PM
C :\U se rs
\a pu lle n\
D oc um en ts \M
S_
-1
-V A
D ub lin E
H R
M _G
EN
_R
_a pu lle nV D
XT
7.
rv t
GA-001
COVER
1 1ANP
EHRM INFRASTRUCTURE
UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027 NOVEMBER 8, 2024
100% BID DOCUMENTS
557-22-70022-192
VARIOUS
EHRM INFRASTRUCTURE UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027
VA PROJECT #: 557-22-700
DJR
NORTH
NORTH
DRAWING LIST - VOLUME 2 OF 4
SHEET NUMBER SHEET NAME DWG OF DWG
GENERAL
GA-001 COVER 1 1
ARCHITECTURAL
A-001 ARCHITECTURAL SYMBOLS, ABBREVIATIONS AND GENERAL NOTES 1 56
01.A-411 BUILDING 1, LEVEL A, TELECOM ROOM 101-1 PLANS 2 56
01.A-421 BUILDING 1, LEVEL B, TELECOM ROOM 207-1 PLANS 3 56
02.A-401 BUILDING 2, LEVEL C, TELECOM ROOM BM123B-2 PLANS 4 56
02.A-411 BUILDING 2, LEVEL A, TELECOM ROOM 104-2 PLANS 5 56
02.A-421 BUILDING 2, LEVEL B, TELECOM ROOM 209A-2 PLANS 6 56
03.A-401 BUILDING 3, LEVEL C, TELECOM ROOM BM101A-3 PLANS 7 56
03.A-411 BUILDING 3, LEVEL A, TELECOM ROOM 112A-3 PLANS 8 56
03.A-421 BUILDING 3, LEVEL B, TELECOM ROOM 219-3 PLANS 9 56
04.A-401 BUILDING 4, LEVEL C, TELECOM ROOM BM105-4 PLANS 10 56
04.A-411 BUILDING 4, LEVEL A, TELECOM ROOM 118-4 PLANS 11 56
04.A-421 BUILDING 4, LEVEL B, TELECOM ROOM 202-4 PLANS 12 56
05.A-411 BUILDING 5, LEVEL A, TELECOM ROOM C137-5 PLANS 13 56
06.A-411 BUILDING 6, LEVEL A, TELECOM ROOM 103-6 PLANS 14 56
06.A-421 BUILDING 6, LEVEL B, TELECOM ROOM 226-6 PLANS 15 56
08.A-411 BUILDING 8, LEVEL A, TELECOM ROOM 172C-8 PLANS 16 56
08.A-421 BUILDING 8, LEVEL B, TELECOM ROOM 213-8 PLANS 17 56
09.A-421 BUILDING 9, LEVEL B, TELECOM ROOM 210A-9 PLANS 18 56
10.A-401 BUILDING 10, LEVEL C, TELECOM ROOM BM107A-10 PLANS 19 56
10.A-411 BUILDING 10, LEVEL A, TELECOM ROOM 130-10 PLANS 20 56
10.A-421 BUILDING 10, LEVEL B, TELECOM ROOM 205-10 PLANS 21 56
11.A-401 BUILDING 11, LEVEL C, TELECOM ROOM BM101A-11 PLANS 22 56
11.A-411 BUILDING 11, LEVEL A, TELECOM ROOM 125-11 PLANS 23 56
11.A-421 BUILDING 11, LEVEL B, TELECOM ROOM 235-11 PLANS 24 56
12.A-401 BUILDING 12, LEVEL C, TELECOM ROOM BM103A-12 PLANS 25 56
12.A-411 BUILDING 12, LEVEL A, TELECOM ROOM 117A-12 PLANS 26 56
12.A-421 BUILDING 12, LEVEL B, TELECOM ROOM 232A-12 PLANS 27 56
13.A-411 BUILDING 13, LEVEL A, TELECOM ROOM 141-13 PLANS 28 56
13.A-421 BUILDING 13, LEVEL B, TELECOM ROOM 224-13 PLANS 29 56
14.A-401 BUILDING 14, LEVEL C, TELECOM ROOM BM104A-14 PLANS 30 56
14.A-411 BUILDING 14, LEVEL A, TELECOM ROOM 101A-14 PLANS 31 56
14.A-421 BUILDING 14, LEVEL B, TELECOM ROOM 232-14 PLANS 32 56
15.A-411 BUILDING 15, LEVEL A, TELECOM ROOM 107-15 PLANS 33 56
15.A-421 BUILDING 15, LEVEL B, TELECOM ROOM 230-15 PLANS 34 56
16.A-401 BUILDING 16, LEVEL C, TELECOM ROOM B11A-16 PLANS 35 56
16.A-421 BUILDING 16, LEVEL B, TELECOM ROOM 216-16 PLANS 36 56
17.A-411 BUILDING 17, LEVEL A, TELECOM ROOM 111-17 PLANS 37 56
17.A-421 BUILDING 17, LEVEL B, TELECOM ROOM 205-17 PLANS 38 56
19.A-411 BUILDING 19, LEVEL A, TELECOM ROOM 117-19 PLANS 39 56
19.A-421 BUILDING 19, LEVEL B, TELECOM ROOM 216A-19 PLANS 40 56
25.A-411 BUILDING 25, LEVEL A, TELECOM ROOM 101A-25 PLANS 41 56
26.A-401 BUILDING 26, LEVEL C, TELECOM ENCLOSURE BM108B-26 PLANS 42 56
26.A-411 BUILDING 26, LEVEL A, TELECOM ROOM 106-26 PLANS 43 56
27.A-411 BUILDING 27, LEVEL A, TELECOM ROOM 107-27 PLANS 44 56
28.A-411 BUILDING 28, LEVEL A, TELECOM ROOM 108-28 PLANS 45 56
29.A-411 BUILDING 29, LEVEL A, TELECOM ENCLOSURE 113A-29 PLANS 46 56
30.A-411 BUILDING 30, LEVEL A, TELECOM ENCLOSURE 104-30 PLANS 47 56
85.A-411 BUILDING 85, LEVEL A, TELECOM ROOM 121-85 PLANS 48 56
86.A-411 BUILDING 86, LEVEL A, TELECOM ROOM 106-86 PLANS 49 56
87.A-411 BUILDING 87, LEVEL A, TELECOM ROOM 120-87 PLANS 50 56
87.A-412 BUILDING 87, LEVEL A, TELECOM ROOM 169-87 PLANS 51 56
89.A-411 BUILDING 89, LEVEL A, TELECOM ROOM 1215-89 PLANS 52 56
A-506 PARTITION TYPES AND ARCHITECTURAL DETAILS 53 56
A-601 DOOR SCHEDULE, ELEVATIONS AND DETAILS 54 56
A-602 GENERAL NOTES, BASIS OF DESIGN, ABBREVIATIONS AND FINISH DETAILS 55 56
A-603 ROOM FINISH SCHEDULE 56 56
VOLUME 2 OF 4
5070L
IC
E N
S E D A RC H I T ECT
DA
V ID J . REICHARD
NOR T H CA RO L I NA
Docusign Envelope ID: 4081B0C2-2BE7-4DDD-B6CF-B1CCFE1038E3
11/7/2024
DEMOLITION KEYNOTE
DOOR NUMBERTYPICAL KEYNOTE CEILING/ SOFFIT
HEIGHT 10
CR CARD READER
X'-X" A.F.F.
1.
2.
3.
4.
5.
1.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
25.
1.
2.
GENERAL
ALL EXISTING CONDITIONS ARE BASED ON THE BEST AVAILABLE INFORMATION AT THE TIME OF SURVEY AND
VISUAL INSPECTION. CONTRACTOR SHALL FIELD VERIFY EXISTING CONDITIONS.
ELEMENTS SHOWN WITH LIGHT GRAY LINES ARE EXISTING TO REMAIN. ELEMENTS SHOWN WITH DARK DASHED LINES ARE EXISTING TO BE DEMOLISHED. DEMOLITION SHALL INCLUDE, BUT NOT BE LIMITED TO, THOSE
ELEMENTS SHOWN.
ALL WORK SHALL BE COORDINATED BETWEEN TRADES
FOR FINISHES IN ALL NEW TELECOM ROOMS, SEE ROOM FINISH SCHEDULE ON SHEET A-602.
ALL WORK SHALL BE COORDINATED WITH THE COR TO MINIMIZE DISRUPTION OF AREAS OUTSIDE OF THE
PROJECT LIMITS OF WORK.
PHASING
THIS PROJECT WILL BE IMPLEMENTED IN PHASES. THE FIRST PHASE WILL INCLUDE THE HEAD-END EQUIPMENT AND FIBER IMPROVEMENTS TO ACHIEVE THE REDUNDANCY FEEDING OF THE TELECOMMUNICATION ROOMS.
THE SECOND PHASE WILL CONSTRUCT ONE OR MORE TELECOMMUNICATIONS ROOMS FOR EACH BUILDING IN A TIMED SEQUENCE UNDER A CONSTRUCTION SCHEDULE PROVIDED BY THE CONTRACTOR AND APPROVED BY THE COR, WITH HVAC SYSTEM TO BE INSTALLED AND ACTIVE. THE THIRD PHASE WILL INCLUDE DISTRIBUTION OF CABLING FROM THE COMPLETED TELECOMMUNICATION ROOMS TO THE DATA RECEPTACLES WITHIN THE APPROPRIATE DISTANCE OF THOSE ROOMS AND CONSTRUCTION OF MORE TELECOMMUNICATIONS ROOMS.
ALL WORK
INDICATIONS OF PROJECT LIMITS OR LINES OF DEMARCATION ARE SHOWN FOR GENERAL SCOPE DEFINITION AND REFLECT THE UNDERSTANDING OF THE DESIGNERS AS TO THE LIMITATIONS OF THE WORK AREA. ACTUAL CONTRACT LIMITS ARE TO BE DETERMINED BY AGREEMENT BETWEEN THE COR/VA AND THE CONTRACTOR
BEFORE THE START OF THE WORK.
DRAWINGS ARE PREPARED USING PRODUCT DIMENSIONS AND DETAILS FROM THE BASIS OF DESIGN PRODUCT. PRODUCTS MAY CHANGE IN DIMENSION AND DETAIL BEFORE THEY ARE INCORPORATED INTO WORK. PRODUCTS FROM OTHER MANUFACTURER'S ARE ALSO ACCEPTABLE. DIMENSIONS AND DETAILS FOR ALTERNATE PRODUCTS MAY VERY FROM BASIS OF DESIGN. CONTRACTOR SHALL VERIFY INSTALLATION REQUIREMENTS FOR ALL PRODUCTS TO BE INCORPORATED INTO WORK (INCLUDING THICKNESS FOR RECESSED OR SEMI-RECESSED PRODUCTS) AND IS RESPONSIBLE FOR ACCOMMODATING AND COORDINATING CHANGES TO OTHER MATERIALS OR PRODUCTS THAT ARE NECESSARY BECAUSE OF THESE DIFFERENCES.
THE DRAWINGS AND SPECIFICATIONS ARE SEPARATED INTO DISCIPLINES FOR CONVENIENCE. THE SEPARATIONS ARE USED ONLY FOR THE PURPOSES OF CONVENIENCE AND REFERENCE AND IN NO WAY DO THEY DEFINE OR LIMIT THE SCOPE OR INTENT OF ANY PART OF THE DRAWINGS AND SPECIFICATIONS AS A WHOLE. THE FACT THAT THE DRAWINGS ARE SEPARATED IN NO WAY SUGGESTS THAT THE WORK IS NOT TO
BE CONSTRUCTED AS A COMPLETE, INTEGRATED AND UNIFIED WHOLE.
THE DRAWINGS AND SPECIFICATIONS, INCLUDING DRAWINGS PREPARED BY SPECIFIC ENGINEERING DISCIPLINES ARE COMPLEMENTARY; ITEMS SHOWN IN ANY ONE LOCATION IN THE DRAWINGS SHALL BE CONSIDERED TO BE REQUIREMENTS OF THE CONTRACT FOR CONSTRUCTION. IN THE EVENT OF AN INCONSISTENCY BETWEEN THE DRAWINGS AND SPECIFICATIONS, OR WITHIN EITHER DOCUMENT, THE CONTRACTOR SHALL SEEK CLARIFICATION OR INTERPRETATIONS FROM THE COR/VA PRIOR TO BIDDING.
WHERE INCONSISTENCIES ARE NOT CLARIFIED PRIOR TO BIDDING, AND WHERE THE ACTUAL SOLUTION OR INTENT CANNOT BE REASONABLY INFERRED, THE CONTRACTOR SHALL PROVIDE THE BETTER QUALITY OR
GREATER QUAINTLY OF WORK.
THE CONTRACTOR IS RESPONSIBLE FOR CHECKING ALL FIELD CONDITIONS (BOTH EXPOSED AND CONCEALED) AND DIMENSIONS AS THEY RELATE TO THIS PROJECT, FOR EACH PHASE. SHOULD DISCREPANCIES EXIST BETWEEN THE WORK INDICATED AND ACTUAL FIELD CONDITIONS. NOTIFY THE COR/VA PRIOR TO PROCEEDING
WITH THE WORK.
THE CONTRACTOR IS RESPONSIBLE TO COORDINATE WITH OTHER TRADES REGARDING THE LOCATION AND SIZE OF PIPES, EQUIPMENT, FIXTURE, CONDUIT, DUCTS, OPENINGS, SWITCHES, OUTLETS, ETC., SO THAT INTERFERENCE BETWEEN THE INSTALLATION OR THE PROGRESS OF THE WORK OF ANY CONTRACTOR OR THE SUBCONTRACTOR ON THE PROJECT CAN BE MINIMIZED IN THE FIELD. SEE SPEC SECTION 01 33 23 SHOP
DRAWINGS.
IN SPACES WITH HIGH CONCENTRATION OF INTER-RELATED EQUIPMENT, PIPING, CONDUIT, AND DUCTWORK (SUCH AS CORRIDORS, MECHANICAL ROOMS, TELECOM ROOMS, ETC), PROVIDE COORDINATION DRAWINGS CLEARLY DEPICTING THE LAYOUT (BOTH PLAN AND ELEVATION, OR PERSPECTIVE) BASED ON FIELD CONDITION. CONTRACTOR TO CLEARLY DEFINE IN ADVANCE OF CONSTRUCTION THE RELATIONSHIP OF ALL PIPING CONDUIT, DUCTWORK, AND EQUIPMENT. DEMONSTRATE CLEARANCE SPACE SUFFICIENT TO SERVICE
THE EQUIPMENT. SEE SPEC SECTION 01 33 23 SHOP DRAWINGS.
COMPLY WITH ALL APPLICABLE FEDERAL, STATE AND LOCAL CODES.
CONTRACTOR IS RESPONSIBLE FOR OBTAINING ALL CONSTRUCTION PERMITS.
CONTRACTOR SHALL PREPARE A PLAN SHOWING LAYDOWN AREA, SECURITY FENCE, DUMPSTER LOCATION, SCAFFOLDING, AND ACCESS FOR COR/VA REVIEW AND APPROVAL.
PROVIDE METAL BACKING AT WALLS AS REQUIRED FOR MOUNTING OF WALL-MOUNTED ITEMS, INCLUDING BUT NOT LIMITED TO WALL PROTECTION, SHELVING, CASEWORK, EQUIPMENT, PLUMBING, ETC. CUT AND PATCH GYP BD IN EXISTING WALLS FOR INSTALLATION OF NEW METAL BACKING WHERE REQUIRED. PROVIDE METAL BACKING IN WALLS AT WATER CLOSET LOCATIONS FOR GRAB BAR INSTALLATION WHETHER GRAB BARS ARE
INDICATED OR NOT.
PROVIDE SUPPLEMENTAL FRAMING AT WALL OPENINGS INCLUDING KING STUDS, JACK STUDS, AND CRIPPLE
STUDS, AS REQUIRED FOR COMPLETION OF THE WORK.
PROVIDE STRUCTURAL SUPPORTS ABOVE CEILING WHERE REQUIRED FOR CEILING HUNG EQUIPMENT.
FURR OUT AROUND COLUMNS, PIPES, UTILITIES, ETC., WITH THE MINIMUM DEPTH NECESSARY TO CONCEAL
PIPES.
CLEAN PAINT OFF ALL NEW AND EXISTING FIRE LABELS IN SCOPE OF WORK TO ALLOW READABILITY.
ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
ALL PRESSURE TREATED WOOD SHALL BE ISOLATED FROM METAL DECK AND / OR METAL STUDS TO PREVENT
CORROSION. ALL FASTENERS IN PRESSURE TREATED WOOD SHALL BE STAINLESS STEEL.
PROVIDE SEALANT AT ALL INTERSECTIONS / JOINTS BETWEEN DIFFERENT MATERIALS.
ALL ITEMS AND MATERIALS SHOWN, INDICATED, OR REQUIRED FOR A COMPLETE PROJECT SHALL BE
PROVIDED AND INSTALLED BY THE CONTRACTOR (UNO).
DRAWINGS SCALES INDICATED ARE FOR REFERENCE ONLY, WRITTEN DIMENSIONS SHALL GOVERN.
SEAL ANY THRU WALL PENETRATIONS AT EXTERIOR WALLS FROM MEP EQUIPMENT LINES.
CONTRACTOR TO PROVIDE FIRE RETARDANT CAULK AT ANY PENETRATIONS TO FIRE TREATMENT PLYWOOD.
CONTRACTOR TO ASSUME ALL CORRIDOR WALLS 1HR RATED AND ALL FLOOR PENETRATIONS 2HR RATED, UNO. CONTRACTOR TO NOTIFY ARCHITECT OF ANY DISCREPANCY.
AT ALL NEW FIRE EXTINGUISHER CABINETS, PROVIDE A NEW CLEAN AGENT FIRE EXTINGUISHER WITHIN 75'-0"
OF THE TELECOM ROOM.
WHERE INFORMATION IS NOT INDICATED ON FIRE RATINGS, LIGHT DIFFUSERS, MECHANICAL DIFFUSERS OR FIRE PROTECTION, ON CEILING GRIDS, THE INFORMATION WAS NOT AVAILABLE FROM THE VA AT THE TIME OF
SUBMISSION.
RENOVATION
PROTECT EXISTING ITEMS, EQUIPMENT, FINISHES, ETC. TO REMAIN. REPAIR / REPLACE / RESTORE, CONDITIONS THAT ARE DAMAGED OR DISTURBED AS A RESULT OF DEMOLITION OR NEW WORK.
CONTRACTOR SHALL MINIMIZE DOWNTIME ASSOCIATED WITH SCHEDULED SHUTDOWNS. COORDINATE WITH
COR/VA.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
1.
2.
1.
2.
3.
GENERAL
KEYNOTES AND DRAWINGS ARE INTENDED TO GRAPHICALLY REPRESENT GENERAL WORK AND DO NOT PORTRAY THE FULL SCOPE OF THE PROJECT. SEE SPECIFICATIONS FOR DETAILED REQUIREMENTS. THIS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF PROVIDING ALL DEMOLITION REQUIRED FOR
COMPLETION OF THE PROJECT.
REMOVE EXISTING CONSTRUCTION AS DESIGNATED AND CLEAR AREA OF DEBRIS PRIOR TO PROCEEDING WITH
NEW CONSTRUCTION.
VERIFY ALL EXISTING CONDITIONS PRIOR TO BEGINNING WORK. NOTIFY COR/VA AND ARCHITECT OF ANY
CONFLICTS PRIOR TO PROCEEDING WITH DEMOLITION.
COORDINATE WITH COR/VA FOR WORKING HOURS ALLOWED FOR DEMOLITION AND WASTE REMOVAL.
COORDINATE WITH COR/VA FOR SCHEDULED USE OF CONSTRUCTION ACCESS ROUTES (INCLUDING USE OF FREIGHT ELEVATOR IF REQUIRED), TRANSPORTATION, AND LOCATIONS OF ITEMS SUCH AS DUMPSTERS.
COORDINATE WITH COR/VA FOR ANY DOWNTIME ON ALL BUILDING SYSTEMS. PROVIDE TEMPORARY SERVICES
DURING INTERRUPTIONS OF EXISTING UTILITIES.
CONDUCT DEMOLITION TO MINIMIZE INTERFERENCE WITH VA'S NORMAL OPERATION AND WITH ADJACENT
BUILDING AREAS.
ALL DEMOLITION WORK SHALL BE PERFORMED WITH DUE CARE AND DILIGENCE IN ORDER TO PREVENT ARBITRARY DAMAGE OR INTERRUPTIONS OF SERVICE OR CONCEALED UTILITIES INTENDED TO REMAIN IN SERVICE (INCLUDING FIRE PROTECTION). DISCOVERY OF UTILITIES OR CONDITIONS DIFFERING FROM THOSE
INDICATED OR THAT ARE NOT IDENTIFIED, SHALL BE REPORTED TO THE COR/VA.
DO NOT ENCROACH ON ADJACENT OCCUPIED AREAS NOT IDENTIFIED WITHIN THE SCOPE OF THE PROJECT
(UNO).
RECORD EXISTING CONDITIONS BY USE OF ANY COMBINATION OF MEASURED DRAWINGS AND
PRECONSTRUCTION PHOTOGRAPHS.
CONTRACTOR SHALL NOTIFY COR/VA OF ANY AREA REQUIRING DEMOLITION OTHER THAN SHOWN IN THESE DRAWINGS DUE TO UNFORESEEN CONDITIONS, TO ACCOMMODATE INSTALLATION OF ALL OTHER TRADES (INCLUDING ROOF PENETRATIONS, ELECTRICAL, OR DATA). AFTER SUCH DEMOLITION AND INSTALLATION, PATCH / REPAIR MATERIALS AND FINISHES TO MATCH EXISTING.
CONTRACTOR SHALL PROTECT AREA ADJACENT TO THE DEMOLITION AND NEW CONSTRUCTION WORK TO PREVENT DAMAGES. IF DAMAGED, PATCH / REPAIR. REPAIR OR REPLACE ITEMS DAMAGED DURING
CONSTRUCTION ACTIVITIES AT NO ADDITIONAL COST.
AT AREAS INDICATED TO BE PATCHED AND REPAIRED FOR ADDITION AND RENOVATION PROJECTS, THE CONSTRUCTION AND ASSEMBLY OF THE PATCH / REPAIR SHALL MATCH THE ASSEMBLY AND INTEGRITY OF THE ADJACENT EXISTING CONSTRUCTION, FOR FIRE RATING, MATERIALS, FINISH, THICKNESS, AND QUALITY.
REFER TO STRUCTURAL, MECHANICAL, PLUMBING, ELECTRICAL, VENDOR DRAWINGS, AND SPECIFICATIONS
FOR ADDITIONAL DEMOLITION ITEMS AND INFORMATION.
COORDINATE WITH COR/VA ON WHAT ITEMS ARE TO BE REMOVED, DISPOSED OF, SALVAGED, AND/OR
REINSTALLED.
- REMOVED & DISPOSED OF ITEMS: SHALL BE PROPERLY DISPOSED OF, OFF PROJECT GROUNDS.
COORDINATE WITH COR/VA.
- REMOVED & SALVAGED ITEMS: SHALL BE CLEANED, PACKED OR CRATED AFTER CLEANING, AND LABELED TO IDENTIFY THE CONTENTS OF CONTAINERS. PROTECT AND TRANSPORT ITEMS TO VA STORAGE AREA.
- REMOVED & REINSTALLED ITEMS: SHALL BE CLEANED AND REPAIRED TO FUNCTIONAL CONDITION ADEQUATE FOR INTENDED USE, PACKED OR CRATED AFTER CLEANING AND LABELED TO IDENTIFY THE CONTENTS OF THE CONTAINERS. PROTECT AND TRANSPORT ITEMS TO TEMPORARY STORAGE, REINSTALL
ITEMS IN LOCATIONS INDICATED.
PATCH / REPAIR ALL MATERIALS AND SURFACES CUT OR DAMAGED DURING DEMOLITION WITH MEANS AND
METHODS SO AS TO NOT TO VOID EXISTING WARRANTIES.
AFTER REMOVAL OF EXISTING CONCRETE OR CMU WALLS. FILL FLOOR VOIDS UP TO FINISH CONCRETE LEVEL
AND PERFORM FLOOR LEVELING FOR ENTIRE AREA OF RENOVATION.
WHERE EXISTING CONSTRUCTION IS TO BE CUT OR REMOVED, PROVIDE SMOOTH AND STRAIGHT CUT JOINTS THAT ARE STRUCTURALLY SOUND. PATCH / REPAIR ADJACENT SURFACES TO MATCH EXISTING AND PROVIDE
IMPERCEPTIBLE TRANSITION (UNO).
WHERE DEMOLITION WORK UNCOVERS OR LEAVES OPENINGS IN PARTITIONS / CEILINGS OR INCOMPLETE PARTITIONS / CEILINGS, EXTEND, RESTORE, AND/OR CLOSE OPENING IN PARTITIONS / CEILINGS AS INDICATED AND/OR AS REQUIRED TO MAINTAIN FIRE RATINGS. MATCH EXISTING CONSTRUCTION, (UNO), WITHIN THE LIMITS AND TOLERANCES FOR MATERIALS AS SPECIFIED OR RECOMMENDED BY THE MANUFACTURER.
REFINISH SURFACES TO ALIGN FLUSH WITH EXISTING.
CEASE OPERATIONS IMMEDIATELY IF THE STRUCTURE APPEARS TO BE IN DANGER AND NOTIFY THE COR/VA
AND ARCHITECT/ENGINEER. DO NOT RESUME OPERATIONS UNTIL DIRECTED.
CONTRACTOR IS RESPONSIBLE FOR SHORING AND TEMPORARY SUPPORT OF STRUCTURE NECESSARY DUE TO DEMOLITION IN ORDER TO MAINTAIN THE INTEGRITY OF RELEVANT STRUCTURE. CONTRACTOR SHALL PROVIDE ENGINEERED PLANS FOR SHORING SIGNED AND SEALED BY REGISTERED ENGINEER LICENSED IN
THE STATE IN WHICH THE PROJECT IS LOCATED.
ALL EXISTING SIGNAGE NOT BEING REUSED IN THE PROJECT TO BE HANDED OVER TO COR/VA DURING
DEMOLITION.
LIFE SAFETY
ALL NECESSARY PATHS OF EGRESS AND EXITS SHALL BE MAINTAINED, PROTECTED AND CLEAR, UNLESS AN
ALTERNATIVE EGRESS PATH OR METHOD IS PROVIDED WHICH MEETS THE RELEVANT CODES.
DO NOT DISABLE OR DISRUPT ANY BUILDING FIRE OR LIFE SAFETY SYSTEMS WITHOUT PRIOR WRITTEN NOTICE
TO THE COR/VA.
HAZARDOUS MATERIALS
IF HAZARDOUS MATERIALS ARE SUSPECTED OR ENCOUNTERED, IMMEDIATELY SUSPEND WORK IN AREA OF SUSPECTED CONTAMINATION, WITHDRAW FROM AREA, AND NOTIFY COR/VA AND ARCHITECT/ENGINEER IN
WRITING.
CONTRACTOR SHALL COORDINATE WITH COR/VA AND/OR ARCHITECT/ENGINEER ON RESPONSIBILITY OF
REMOVAL OF HAZARDOUS MATERIALS (KNOWN OR UNKNOWN) PRIOR TO CONTRACT.
COMPLY WITH REQUIREMENTS OF EPA, NATIONAL EMISSION STANDARDS, OSHA REGULATIONS, AND ALL
OTHER APPLICABLE REGULATIONS ON HAZARDOUS MATERIALS.
1.
2.
3.
4.
GENERAL
CONTRACTOR A IS RESPONSIBLE FOR REMOVING AND RELOCATING ALL EXISTING FURNITURE, FIXTURES AND
EQUIPMENT FOR RENOVATION PROJECTS PRIOR TO CONSTRUCTION.
REFER TO MECHANICAL, ELECTRICAL, PLUMBING, FIRE ALARM AND LOW VOLTAGE DRAWINGS FOR ADDITIONAL
REQUIRED UTILITY CONNECTIONS AND LOCATIONS.
REFER TO G-002 FOR STANDARD MOUNTING HEIGHTS. REFER TO EQUIPMENT DRAWINGS FOR LOCATIONS AND ADDITIONAL DIMENSIONS. PROVIDE 16 GAUGE BACKING FOR ALL WALL MOUNTED EQUIPMENT AS REQUIRED BY
THE MANUFACTURER’S REQUIREMENTS FOR INSTALLATION.
WHEREVER EXISTING EQUIPMENT, PIPING, DUCTS, ETC., ARE REQUIRED TO BE REMOVED, SUCH REMOVAL SHALL INCLUDE ALL ANCHORS, HANGERS, BRACING, FOUNDATIONS, ASSOCIATED WIRING CONDUIT, ETC. AFTER REMOVAL, AFFECTED CONSTRUCTION AND SURFACES, SUCH AS FLOORS, WALLS, BASES, AND CEILINGS, SHALL
BE FINISHED TO MATCH ADJACENT SURFACES (UNO).
1.
2.
3.
4.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
21.
22.
23.
24.
1.
GENERAL
REFER TO INTERIOR PARTITION TYPES, PLANS, AND SPECIFICATIONS.
REFER TO FLOOR PLANS FOR FIRE-RATED AND/OR SMOKE PARTITION / BARRIER LOCATIONS.
AT RATED ASSEMBLIES, THE CONTRACTOR IS TO VERIFY THE GYP. BD. TYPE AND MANUFACTURER BASED ON THE WRITTEN DESCRIPTIONS FOR THE APPROPRIATE LISTED ASSEMBLY RATING SPECIFICATIONS.
CONTRACTOR TO PROVIDE ALL ADDITIONAL FRAMING AS REQUIRED FOR ALL OPENINGS AND SUPPLEMENTAL
FRAMING ABOVE PARTITIONS.
ALL WORK
ALL INTERIOR PARTITIONS SHALL BE TYPE M4.0 (UNO).
ALL INTERIOR PARTITIONS TO RECEIVE SOUND ATTENUATION INSULATION (UNO).
GYP. BD. REQUIREMENTS:
- ALL GYP. BD. TO BE 5/8" TYPE "X" (UNO).
- PROVIDE 5/8" TYPE "X" MOISTURE AND MOLD RESISTANT GYP. BD. AT ALL LOCATIONS WHERE WATER
PRODUCING DEVICES MAY BE PRESENT OR SPLASHED ONTO THE WALL SURFACE (I.E. LAVATORIES, WATER CLOSETS, HOSE BIBS, ETC.). EXTEND GYP. BD., A MINIMUM OF 4'-0' IN ALL DIRECTIONS FROM CENTER OF
DEVICE.
- PROVIDE 5/8" TYPE "X" MOISTURE AND MOLD RESISTANT GYP. BD. AT INTERIOR BOUNDARY AT EXTERIOR
WALL, INCLUDING COLUMN FURROUTS THAT ARE INTEGRATED INTO THE EXTERIOR WALL.
- PROVIDE TYPE "X" IMPACT RESISTANT GYP. BD. 4'-0" H AT ALL WALLS IN PATIENT ROOMS, EQUIPMENT
ALCOVES, AND ADDITIONAL LOCATIONS AS NOTED ON THE DRAWINGS.
- PROVIDE TILE BACKER BOARD AT ALL AREAS TO RECEIVE TILE FINISHES.
ALL PARTITIONS AROUND TR’S SHALL EXTEND FROM THE FLOOR SLAB AND SEAL TO THE UNDERSIDE OF THE STRUCTURE/DECK ABOVE WITHOUT ANY OPENINGS NOT FILLED WITH DUCTWORK, PIPES, AND CONDUITS.
CONTRACTOR SHALL VERIFY EXISTING CONDITIONS, INFILL ANY OPENINGS, AND EXTEND PARTITIONS TO STRUCTURE AS REQUIRED. THE PARTITIONS SHALL, AT A MINIMUM, MEET THE M4.0 PARTITION TYPE.
ALL FIRE AND/OR SMOKE PARTITIONS / BARRIER SHALL EXTEND FROM FLOOR SLAB TO THE UNDERSIDE OF THE STRUCTURE - DECK ABOVE. ALL PENETRATIONS SHALL BE SEALED AND PROTECTED WITH FIRE-RATED
ASSEMBLIES TO MAINTAIN THE INTEGRITY OF THE PARTITION / BARRIER.
COSMETIC FURR-OUT AND WING WALLS (NOT INTEGRATED INTO EXTERIOR WALL) MAY TERMINATE 6" ABOVE ADJACENT CEILING. CAP TOP OF WALLS WITH GYP. BD. SUCH THAT FURR-OUT AND WING WALLS DOES NOT CREATE A BREACH IN THE ADJACENT WALL WHICH EXTENDS TO THE UNDERSIDE OF ROOF / FLOOR DECK ABOVE.
ALL FIRE AND OR SMOKE PARTITIONS / BARRIERS ARE TO ABUT THE EXTERIOR GYP. BD. SHEATHING.
FIRE AND/OR SMOKE PARTITION / BARRIER IDENTIFICATION:
- IDENTIFY PARTITIONS ABOVE ACCESSIBLE CEILINGS ON BOTH SIDES OF PARTITION, EXCEPT WITHIN SHAFTS, IN RED 3" HIGH STENCILED BLOCK LETTERING.
- STENCIL MESSAGE SIMILAR TO: "SMOKE PARTITION" OR "1 HOUR FIRE/SMOKE BARRIER"
- LOCATE MESSAGE NOT MORE THAN 10'-0" OC ON CORRIDOR SIDES OF PARTITIONS, WITH AT LEAST ONE
MESSAGE PER ROOM ON ROOM SIDE OF PARTITIONS, AND WITHIN 15'-0" OF THE END OF EACH WALL.
- USE SEMI-GLOSS PAINT.
WHERE RATED PARTITIONS / BARRIERS INTERSECT ONE OF LESSER RATING, THEIR LAYERS OF GYP. BD. SHALL BE CONTINUOUS THROUGH THE WALL OF LESSER RATING. SEAL ALL PENETRATIONS WITH APPROVED LISTED
ASSEMBLIES. THE FOLLOWING PRIORITIES SHALL BE OBSERVED:
- PRIORITY 1 - 3 HOUR FIRE WALL
- PRIORITY 2 - 2 HOUR FIRE WALL
- PRIORITY 3 - 2 HOUR FIRE / SMOKE
- PRIORITY 4 - 2 HOUR FIRE / SHAFT BARRIER
- PRIORITY 5 - 1 HOUR FIRE / SMOKE
- PRIORITY 6 - 1 HOUR SMOKE BARRIER
- PRIORITY 7 - 1 HOUR FIRE / SHAFT BARRIER
- PRIORITY 8 - NON-RATED SMOKETIGHT PARTITIONS
- PRIORITY 9 - NON-RATED PARTITIONS
STAGGER ALL GYP. BD. JOINTS ON OPPOSITE SIDES OF PARTITIONS AS FOLLOWS:
- VERTICAL JOINTS OFFSET 16" HORIZONTALLY.
- HORIZONTAL JOINTS OFFSET 24" VERTICALLY.
CONTROL JOINTS SHALL BE INSTALLED AT ALL CONSTRUCTION CHANGES WITHIN A PLANE OF A PARTITION OR CEILING. AT PARTITION RUNS THAT EXCEED 30'-0" IN LENGTH, CEILING DIMENSIONS THAT EXCEED 50'-0" IN EITHER DIRECTION WITH PERIMETER RELIEF AND 30'-0" WITHOUT, AT WINGS OF "L", "U", AND "T" SHAPED CEILING AREAS, AT BUILDING EXPANSION OR CONTROL JOINTS. CONTROL JOINTS SHALL BE INSTALLED AT EACH DOOR FROM OUTSIDE CORNER OF THE TOP OF DOOR JAMB TO ABOVE CEILING. REFER TO PUBLISHED CONTROL JOINT
DETAILS IN GA 600 FIRE RESISTANCE DEIGN MANUAL.
CONTRACTOR SHALL PROVIDE ADDITIONAL MATERIALS TO MAINTAIN THE APPROPRIATE FIRE RATING WHERE CONTROL JOINTS ARE LOCATED IN FIRE-RATED PARTITIONS / BARRIERS. INSTALLATION SHALL BE PER THE DETAILS SHOWN IN THE LATEST PUBLICATION OF THE USG CONSTRUCTION HANDBOOK, GYPSUM ASSOCIATION
PUBLICATION OR UNDERWRITERS LABORATORY FIRE RESISTANCE DIRECTORY.
ENSURE THAT THE GYP. BD. WALL PANELS ARE NOT OFFSET FROM THE SUBFLOOR (AT ALL CONDITIONS) OR THE
STRUCTURE ABOVE (IF REQUIRING SOUND ATTENUATION INSULATION) GREATER THAN 1/2".
ISOLATE DISSIMILAR METALS.
INSTALL ACOUSTICAL GASKETS AT FLOOR AND CEILING TRACK LOCATIONS.
SEAL ALL PENETRATIONS IN WALLS AS REQUIRED BY ASTM C919.
PROVIDE FIRE SAFING INSULATION AS REQUIRED TO MAINTAIN THE INTEGRITY OF FIRE-RATED PARTITIONS.
ALL VERTICAL PIPING AND COLUMNS EXPOSED IN ROOMS SHALL BE FURRED-OUT AND FINISHED TO MATCH ADJACENT WALLS (UNO). EXCEPTIONS: ELEC. CLOSETS, TELE. CLOSETS, AND MECHANICAL CLOSETS.
WHERE HVAC OR OTHER MECHANICAL, PLUMBING, ELECTRICAL ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORT. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE, AND/OR ACOUSTICAL ISOLATION OF
SPACES WITH APPROPRIATE FIRE STOP MATERIAL.
PROVIDE AND INSTALL ANY STIFFENERS, BRACING, BACK-UP PLATES AND SUPPORTING BRACKETS REQUIRED FOR THE INSTALLATION OF ALL FLOOR MOUNTED OR SUSPENDED MECHANICAL, OR ELECTRICAL ITEMS.
PROVIDE CONTINUOUS STIFFENER CHANNELS AT 4'-0" MAXIMUM VERTICAL SPACING, TYPICAL. ALSO PROVIDE AT MIDPOINT BETWEEN BOTTOM OF STRUCTURE AND HEAD OF INTERIOR WINDOWS AND DOORS AS WELL AS HINGE MIDPOINT AT DOORS. IF DOOR OPENING IS OVER 4'-0" LONG, PROVIDE STIFFENER CHANNELS AT ALL HINGE
POINTS FOR MINIMUM OF 2 STUD SPACES HORIZONTALLY.
AT ALL INTERSECTIONS WITH CEILINGS, PROVIDE METAL STUD FIRE BACKING AT NO GREATER THAN 8'-0" APART
AND AS REQUIRED BY THE FIRE RATED ASSEMBLY.
WHERE COLUMN FURRING STUDS EXCEED THE MANUFACTURER'S RECOMMENDED LIMITING HEIGHT, STUDS
SHALL BE BRACED.
DO NOT TRANSFER DEFLECTION FROM STRUCTURAL BUILDING MEMBERS TO STUDS. CONTRACTOR TO PROVIDE
EITHER OF THE FOLLOWING:
- MAINTAIN CLEARANCE UNDER STRUCTURAL BUILDING MEMBERS TO AVOID DEFLECTION TRANSFER TO
STUDS. PROVIDE EXTENDED LEG CEILING RUNNERS.
- PROVIDE DEFLECTION AND BRIDGING CLIPS.
RENOVATION
MAINTAIN FIRE / SMOKE RATINGS OF EXISTING PARTITIONS AND BARRIERS.
DIMENSIONS
1.
2.
3.
4.
1.
2.
3.
4.
5.
1.
2.
GENERAL
DRAWING SCALES INDICATED ARE FOR
REFERENCE ONLY. WRITTEN DIMENSIONS
SHALL GOVERN.
FIELD VERIFY ALL DIMENSIONS BEFORE
PROCEEDING WITH WORK.
IF DIMENSIONS ARE IN QUESTIONS OR THERE IS
A VARIATION OF +/- 1" FROM THE NOTED
DIMENSION, CONTACT ARCHITECT BEFORE
PROCEEDING WITH CONSTRUCTION.
REFER TO STANDARD MOUNTING HEIGHTS FOR
DIMENSIONS REGARDING PLACEMENT OF
PLUMBING FIXTURES AND PLUMBING FIXTURE
ACCESSORIES.
ALL WORK
DIMENSIONS FOR NEW CONSTRUCTION:
- CENTERLINE OF THE COLUMN
- TO THE EDGE OF STUD IN NEW PARTITIONS
- TO THE FACE OF CONCRETE/MASONRY
WALLS
- TO FINISHED FACE OF EXTERIOR WALLS.
(DIMENSIONS OF FINISHES ARE BASED ON
NOMINAL DIMENSIONS AND MAY VARY BY
MANUFACTURER. REFER TO WALL
SECTIONS.)
DOOR OPENINGS SHALL BE 4" (TYP) FROM THE
PERPENDICULAR WALL OR HINGE SIDE (UNO).
ALLOW FOR PROTRUDING HARDWARE.
ELEMENTS THAT APPEAR TO ALIGN ON
DRAWINGS ARE INTENDED TO ALIGN AND SHALL
BE MADE TO ALIGN (UNO).
ALIGN FINISHED FACE OF CONTINUOUS
PARTITIONS THAT CHANGE PARTITION TYPES
ALONG A STRAIGHT RUN.
CJ = GYPSUM BOARD CONTROL JOINT. REFER
TO SPEC 092900 FOR ADDITIONAL
REQUIREMENTS.
RENOVATION
DIMENSIONS OF EXISTING CONSTRUCTION ARE
TO THE CENTERLINE OF THE COLUMN AND THE
FACE OF EXISTING PARTITIONS.
WHERE INFILLING AN OPENING IN AN EXISTING
PARTITION, BOTH FACES OF THE INFILL SHALL
ALIGN WITH THE EXISTING.
RCP GENERAL NOTES
1.
2.
3.
4.
5.
1.
2.
3.
4.
5.
6.
7.
8.
9.
1.
2.
3.
4.
5.
6.
GENERAL
CONTRACTOR IS TO REVIEW CEILING LAYOUT
AND NOTIFY ARCHITECT OF ANY CONFLICTS
BEFORE PROCEEDING WITH CONSTRUCTION.
COORDINATE WITH MECHANICAL AND
ELECTRICAL DRAWINGS FOR CEILING MOUNTED
DEVICES.
COORDINATE WITH MECHANICAL, PLUMBING,
AND ELECTRICAL FOR ALL ABOVE CEILING
WORK TO MEET CEILING HEIGHTS.
REFER TO ROOM FINISH SCHEDULE FOR
CEILING MATERIALS.
REPLACE CEILING TILES AT THE END OF EACH
SHIFT IN WORK AREAS OUTSIDE OF A RATED
CONSTRUCTION BARRIER. IF THE TILES CANNOT
BE REPLACED, THE SPRINKLER SYSTEM MAY BE
CONSIDERED OUT OF SERVICE IN THESE AREAS
AND A 1-HOUR FIRE RATED SEPARATION WILL
BE REQUIRED BETWEEN THE CONSTRUCTION
AREA AND THE OCCUPIED PORTIONS OF THE
BUILDING.
ALL WORK
LIGHTS, DIFFUSERS, EXIT SIGNAGE, SPRINKLER
HEADS, AND SMOKE DETECTORS SHALL BE
CENTERED IN THE CEILING TILE.
EXIT SIGNAGE TO BE CENTERED OVER DOORS
(UNO).
CENTER CEILING GRID IN BOTH DIRECTIONS OF
THE SPACE (UNO).
ACCESS PANELS ARE NOT PERMITTED IN
SOFFITS. CHECK ALL VALVES, FIRE DAMPERS,
REHEAT BOXES, ETC. FOR ACCESS POINTS.
ARRANGE FIRE AND SMOKE DAMPERS FROM
NON-CORRIDOR SIDE.
THE CONTRACTOR SHALL VERIFY THAT ACCESS
PANELS OF APPROPRIATE SIZE AND TYPE ARE
INSTALLED IN NON-ACCESSIBLE TYPE CEILINGS
WHERE ACCESS, SERVICE, OR ADJUSTMENT TO
MECHANICAL, PLUMBING, ELECTRICAL ITEMS
MAY BE REQUIRED.
PAINT CUT EDGES OF ACT TO MATCH CEILING
TILE WHERE EXPOSED TO VIEW.
PAINT ALL INTERIOR SURFACES OF AIR DUCTS
AND CONVECTOR / BASEBOARD HEATING
CABINETS THAT ARE VISIBLE THROUGH GRILLES
AND LOUVERS WITH (1) ONE COAT OF FLAT
BLACK PAINT FOR 1'-6" MINIMUM OR BEYOND
LINE OF SIGHT, WHICHEVER IS GREATER.
HANG SUSPENSION SYSTEM INDEPENDENTLY
OF WALLS, COLUMNS, DUCTS, PIPES, AND
CONDUIT.
PROVIDE METAL BACKING AND/OR BRACING AS
REQUIRED FOR LIGHT FIXTURES EXCEEDING
50LBS IN WEIGHT OR WEIGHING MORE THAN
THE RATED LOAD CAPACITY OF THE OUTLET
BOX ON WHICH THE FIXTURE WILL BE MOUNTED.
REFER TO NFPA 70 NATIONAL ELECTRICAL CODE
CHAPTER 3.
RENOVATION
REPAIR EXISTING CEILING GRID AND TILES AS
NEEDED AT CONSTRUCTION TIE-INS.
WHERE NEW CEILINGS ARE INDICATED, REMOVE
ALL EXISTING CEILINGS AND ACCESSORIES TO
ALLOW FOR PROPER INSTALLATION OF NEW
CEILINGS. PATCH / REPAIR AS NEEDED.
IN TELECOM ROOMS, CONTRACTOR IS
RESPONSIBLE FOR REMOVING ALL CEILINGS TO
EXPOSED UNDERSIDE OF STRUCTURE UNO.
EXTEND/TRIM EXISTING CEILING GRIDS TO NEW
PARTITION.
PROVIDE NEW ANGLE MOULDING TO RECEIVE
CEILING SYSTEM ALONG NEW PARTITION. MITER
AND ATTACH TO EXISTING ANGLE MOULDING AS
REQUIRED.
CUT NEW CEILING TILE TO FILL ALL OPENING IN
SPACE. REPLACE ANY CEILING TILES DAMAGED
DURING CONSTRUCTION.
DOOR GENERAL NOTES
1.
2.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
1.
GENERAL
REFER TO THE DOOR AND HARDWARE
SCHEDULE, ELECTRICAL AND LOW VOLTAGE
DRAWINGS, AND SPECIFICATIONS FOR
ADDITIONAL INFORMATION.
FIELD VERIFY EXISTING CONDITIONS WHERE
NEW HARDWARE COMPONENTS ARE
SCHEDULED ON EXISTING DOORS OR WHERE
MODIFICATION TO EXISTING DOOR HARDWARE
ARE REQUIRED. COORDINATE INSTALLATION OF
DOOR HARDWARE TO SUIT EXISTING
CONDITIONS AND TO PROVIDE FOR PROPER
OPERATION.
ALL WORK
ALL NEW DOOR OPENINGS LOCATED 4" FROM
ADJACENT WALL AT HINGE SIDE, UNO.
PROVIDE FINISHED DOOR VERTICAL AND TOP
EDGES SAME AS DOOR FACE FINISH.
ALL DOORS SHALL HAVE STANDARD 5/8"
UNDERCUT (UNO).
ALL CROSS-CORRIDOR DOORS SHALL BE
NARROW LITE WHICH INCLUDE VIEW LITES THAT
MEET ANSI / ADA REQUIREMENTS (UNO).
ALL FRAMES SHALL BE FULLY WELDED. KNOCK-
DOWN FRAMES ARE NOT PERMITTED.
AT ALL EXTERIOR OPENINGS, PROVIDE FRAMES
WITH FOAM-IN-PLACE INSULATION.
SEAL AROUND THE FULL PERIMETER OF THE
DOOR FRAME .
TEXTURED (KNURLED) SURFACES REQUIRED ON
DOOR HANDLES LEADING TO HAZARDOUS
ROOMS.
USE WALL MOUNTED DOOR STOPS WHERE
POSSIBLE. OTHERWISE, USE HEAVY DUTY
CONCEALED OVERHEAD DOOR STOPS.
PROVIDE HEAVY DUTY HINGES ON DOORS OVER
3'-6" W.
COORDINATE WITH COR/VA FOR FINAL KEYING
REQUIREMENTS.
PROVIDE SMOKE LABELED GASKETING ON ALL
FIRE / SMOKE RATED DOORS.
PROVIDE ALUMINUM THRESHOLD,
WEATHERSTRIPPING, DOOR BOTTOM, AND
RAINDRIP AT ALL EXTERIOR DOORS.
PROVIDE CONDUIT TO THE TOP OF DOOR
HEADERS IN CENTER FOR DOUBLE DOORS AND
TO NON-HINGE SIDE FOR SINGLE DOORS
SCHEDULED TO RECEIVE ELECTRONIC
HARDWARE.
ELECTRIC STRIKES SHALL BE FAIL SECURE
(UNO).
ALL EXTERIOR DOORS TO BE INSULATED.
RENOVATION
COORDINATE CONDUITS AND/OR WIRING
REQUIREMENTS FOR DOORS / FRAMES /
HARDWARE DURING FRAME INSTALLATION FOR
ELECTRICAL CONNECTIONS FOR LOCKS,
STRIKES, ETC. TO ENSURE PROPER DOOR
OPERATION.
Engineers Architects Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/6
/2
5:
:0
PM
C :\U se rs
\a pu lle n\
D oc um en ts \M
S_
-1
-V A
D ub lin E
H R
M _G
EN
_R
_a pu lle nV D
XT
7.
rv t
A-001
ARCHITECTURAL SYMBOLS,
ABBREVIATIONS AND GENERAL NOTES
1 56ANP
EHRM INFRASTRUCTURE
UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027 NOVEMBER 8, 2024
100% BID DOCUMENTS
557-22-70022-192
VARIOUS
DJR
ARCHITECTURAL SYMBOL LEGENDGENERAL NOTES
DEMOLITION NOTES
EQUIPMENT GENERAL NOTES
WALL TYPES GENERAL NOTES
5070L
IC
E N
S E D A RC H I T ECT
DA
V ID J . REICHARD
NOR T H CA RO L I NA
CR
ENVIRONMENT
MGMT HK
CLOSET
102-1
CORRIDOR
C11-1
1.2
101-1
1.2
3.1
3.4 2.1
3.5
4.1
8' -6
/2
15'-1"
CENTRALIZED
STAFF FAC
MENS TLT
103-1
126 SF
101-1
TR
5.7
5.14.2
5.5
ENVIRONMENT
MGMT HK
CLOSET
102-1
CORRIDOR
C11-1
2.1
3.1
4.1
HUMAN
RESOURCES
OFFICE
101-1
CENTRALIZED
STAFF FAC
MENS TLT
103-1
15'-1"
8' -6
/2
ENVIRONMENT
MGMT HK
CLOSET
102-1
CORRIDOR
C11-1
6.1
CENTRALIZED
STAFF FAC
MENS TLT
103-1
CEILING NOTES:
8'-0" A.F.F. EXISTING ACT
9'-2" A.F.F. TO PLASTER ABOVE CEILING
11'-6" A.F.F. TO BOTTOM OF CONCRETE ABOVE CEILING
10'-6" A.F.F. TO BOTTOM OF BEAM ABOVE CEILING
A.F.F.8' - 0"
HUMAN
RESOURCES
OFFICE
101-1
ENVIRONMENT
MGMT HK
CLOSET
102-1
CORRIDOR
C11-1
6.1
6.26.3
6.4
CENTRALIZED
STAFF FAC
MENS TLT
103-1
101-1
TR
Engineers Architects
# DEMOLITION KEY NOTES:
# NEW KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/6
/2
:5 6:
P
M C
:\U se rs \a pu lle n\ D oc um en ts
\A _2
2-
2-
VA
D ub lin E
H R
M -B ld g
1_ R
_a pu lle nV D
XT
7.
rv t
01.A-411
BUILDING 1, LEVEL A, TELECOM ROOM
101-1 PLANS
2 56ANP
EHRM INFRASTRUCTURE
UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027 NOVEMBER 8, 2024
100% BID DOCUMENTS
557-22-70022-192
DJR
0 2 4 8
NORTH
1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED
AC GRADE PLYWOOD BACK BOARDS IN TELECOM
ROOMS. PLYWOOD SHALL BE MOUNTED WITH
A-SIDE OUT. PAINT PLYWOOD BACK BOARDS P-2.
2.1 NEW FLOORING, INCLUDING UNDERLAYMENT,
AND RUBBER WALL BASE, SEE SPECS AND ROOM
FINISH SCHEDULE.
3.1 NEW DOOR & FRAME IN EXISTING MASONRY
WALL, SEE DOOR SCHEDULE.
3.4 NEW CARD READER, SEE ELECTRICAL
DRAWINGS.
3.5 APPLY SAFETY WINDOW FILM TO INTERIOR FACE
OF GLAZING, AND INSTALL AN EXPANDED METAL
SCREEN AT EXISTING WINDOW.
4.1 NEW ROOM SIGN, SEE SHEET A-602.
4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN
AGENT SIGN, SEE SHEET A-602.
5.1 INSTALL NEW SURFACE MOUNTED FIRE
EXTINGUISHER CABINET.
5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO
MATCH EXISTING.
5.7 FLOOR TRANSITION
6.1 EXPOSED STRUCTURE
6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL
DRAWINGS.
6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.
6.4 WALL MOUNTED HVAC EQUIPMENT, SEE
MECHANICAL DRAWINGS.
Scale: 1/4" = 1'-0"
TELECOM ROOM FLOOR PLAN
Scale: 1/4" = 1'-0"
OFFICE DEMOLITION FLOOR PLAN 0 2 4 8
NORTH
Scale: 1/4" = 1'-0"
OFFICE DEMOLITION REFLECTED CEILING PLAN
0 2 4 8
NORTH
0 2 4 8
NORTH
Scale: 1/4" = 1'-0"
TELECOM ROOM REFLECTED CEILING PLAN
2.1 REMOVE EXISTING FLOOR FINISH AND BASE. PATCH
ALL HOLES AND LEVEL UNEVEN SUBFLOOR.
3.1 REMOVE EXISTING DOOR & FRAME, PREPARE
ROUGH OPENING AS REQUIRED FOR NEW DOOR.
4.1 REMOVE EXISTING SIGNAGE AND TURN OVER TO
VA.
6.1 REMOVE EXISTING ACT CEILING, INCLUDING
ELECTRICAL AND MECHANICAL FIXTURES. SEE
ELECTRICAL AND MECHANICAL DRAWINGS.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
5070L
IC
E N
S E D A RC H I T ECT
DA
V ID J . REICHARD
NOR T H CA RO L I NA
PIPE SPACE
206-1
CONSULT MGMT
208A-1
FEE SVC
OFFICE
208-1
CORRIDOR
CR22-1
4.1
3.1
IRM
207-1
2.1
CORRIDOR
CR21-1
PIPE SPACE
206-1
CONSULT MGMT
208A-1
FEE SVC
OFFICE
208-1
CR22-1
CORRIDOR
1.2
207-1
1.2
3.13.4
2.1
4.1
8'-8 1/2"
9' -2
/2
80 SF
207-1
TR
5.7
5.5
CORRIDOR
CR21-1
5.1
4.2
PIPE SPACE
206-1
CONSULT MGMT
208A-1
FEE SVC
OFFICE
208-1
CORRIDOR
CR22-1
6.4 IRM
207-1
CEILING NOTES:
11'-6" A.F.F. BOTTOM ON CONCRETE
10'-4" A.F.F. BOTTOM OF BEAM
6.6
6.8
CORRIDOR
CR21-1
6.9
PIPE SPACE
206-1
CONSULT MGMT
208A-1
FEE SVC
OFFICE
208-1
CORRIDOR
CR22-1
6.1
6.2
6.3
6.4
CORRIDOR
CR21-1
207-1
TR
Engineers Architects
# DEMOLITION KEY NOTES:
# NEW KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/6
/2
:5 6:
P
M C
:\U se rs \a pu lle n\ D oc um en ts
\A _2
2-
2-
VA
D ub lin E
H R
M -B ld g
1_ R
_a pu lle nV D
XT
7.
rv t
01.A-421
BUILDING 1, LEVEL B, TELECOM ROOM
207-1 PLANS
3 56ANP
EHRM INFRASTRUCTURE
UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027 NOVEMBER 8, 2024
100% BID DOCUMENTS
557-22-70022-192
DJR
0 2 4 8
NORTH
0 2 4 8
NORTH
0 2 4 8
NORTH
0 2 4 8
NORTH
Scale: 1/4" = 1'-0"
IRM ROOM DEMOLITION FLOOR PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM FLOOR PLAN
Scale: 1/4" = 1'-0"
IRM ROOM DEMOLITION REFLECTED CEILING PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM REFLECTED CEILING PLAN
2.1 REMOVE EXISTING FLOOR FINISH AND BASE.
PATCH ALL HOLES AND LEVEL UNEVEN SUBFLOOR.
3.1 REMOVE EXISTING DOOR & FRAME, PREPARE
ROUGH OPENING AS REQUIRED FOR NEW DOOR.
4.1 REMOVE EXISTING SIGNAGE AND TURN OVER TO
VA.
6.4 EXISTING EXPOSED STRUCTURE.
6.6 REMOVE EXISTING LIGHTING, TYP. SEE
ELECTRICAL DRAWINGS.
6.8 DEMOLISH WALL MOUNTED HVAC EQUIPMENT, SEE
MECHANICAL DRAWINGS.
6.9 DEMOLISH EXISTING CABLE TRAY, SEE ELECTRICAL
DRAWINGS.
1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED AC
GRADE PLYWOOD BACK BOARDS IN TELECOM
ROOMS. PLYWOOD SHALL BE MOUNTED WITH
A-SIDE OUT. PAINT PLYWOOD BACK BOARDS P-2.
2.1 NEW FLOORING, INCLUDING UNDERLAYMENT, AND
RUBBER WALL BASE, SEE SPECS AND ROOM
FINISH SCHEDULE.
3.1 NEW DOOR & FRAME IN EXISTING MASONRY WALL,
SEE DOOR SCHEDULE.
3.4 NEW CARD READER, SEE ELECTRICAL DRAWINGS.
4.1 NEW ROOM SIGN, SEE SHEET A-602.
4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN
AGENT SIGN, SEE SHEET A-602.
5.1 INSTALL NEW SURFACE MOUNTED FIRE
EXTINGUISHER CABINET.
5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO
MATCH EXISTING.
5.7 FLOOR TRANSITION
6.1 EXPOSED STRUCTURE
6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL
DRAWINGS.
6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.
6.4 WALL MOUNTED HVAC EQUIPMENT, SEE
MECHANICAL DRAWINGS.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
5070L
IC
E N
S E D A RC H I T ECT
DA
V ID J . REICHARD
NOR T H CA RO L I NA
STORAGE
BM123A-2
REFRIGERATION
COMPRESSOR
RM
BM121-2
STORAGE
BM123-2
CORRIDOR
CRB1-2
2.12.2
3.1
2.1
1.1
4.2
IT
BM123B-2
6'-8"
STORAGE
BM123A-2
REFRIGERATION
COMPRESSOR
RM
BM121-2
STORAGE
BM123-2
CORRIDOR
CRB1-2
1.2
1.2
3.1
3.4
4.1
1.12.25.4
2.1
4.2
5.1
11'-5"
'-8
/2
118 SF
BM123B-2
TR
BM123B-2
5.6
5.5
M4.0
1.2
STORAGE
BM123A-2
REFRIGERATION
COMPRESSOR
RM
BM121-2
STORAGE
BM123-2
CORRIDOR
CRB1-2
6.2
6.3
6.4
6.5
BM123B-2
TR
STORAGE
BM123A-2
REFRIGERATION
COMPRESSOR
RM
BM121-2
STORAGE
BM123-2
CORRIDOR
CRB1-2
CEILING NOTES:
11'-7" A.F.F. BOTTOM OF CONCRETE
10'-7" A.F.F. BOTTOM OF BEAM
6.4
6.46.6
6.6
6.8
6.9
IT
BM123B-2
Engineers Architects
# DEMOLITION KEY NOTES:
# NEW KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/6
/2
:5 0:
P
M C
:\U se rs \a pu lle n\ D oc um en ts
\A _2
2-
2-
VA
D ub lin E
H R
M -B ld g
2_ R
_a pu lle nV D
XT
7.
rv t
02.A-401
BUILDING 2, LEVEL C, TELECOM ROOM
BM123B-2 PLANS
4 56ANP
EHRM INFRASTRUCTURE
UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027 NOVEMBER 8, 2024
100% BID DOCUMENTS
557-22-70022-192
DJR
1.1 NEW WALL, TYP. SEE A-506.
1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED AC
GRADE PLYWOOD BACK BOARDS IN TELECOM
ROOMS. PLYWOOD SHALL BE MOUNTED WITH
A-SIDE OUT. PAINT PLYWOOD BACK BOARDS P-2.
2.1 NEW FLOORING, INCLUDING UNDERLAYMENT, AND
RUBBER WALL BASE, SEE SPECS AND ROOM
FINISH SCHEDULE.
2.2 PATCH FLOORING TO MATCH EXISTING.
3.1 NEW DOOR & FRAME IN EXISTING MASONRY WALL,
SEE DOOR SCHEDULE.
3.4 NEW CARD READER, SEE ELECTRICAL DRAWINGS.
4.1 NEW ROOM SIGN, SEE SHEET A-602.
4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN
AGENT SIGN, SEE SHEET A-602.
5.1 INSTALL NEW SURFACE MOUNTED FIRE
EXTINGUISHER CABINET.
5.4 NEW PAINT AND RUBBER WALL BASE TO MATCH
EXISTING.
5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO
MATCH EXISTING.
5.6 FLOOR TRANSITION AT STATIC DISSIPATIVE TILE
TO EXTEND FROM UNDERSIDE OF TELECOM ROOM
TO ADJACENT ROOM.
6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL
DRAWINGS.
6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.
6.4 WALL MOUNTED HVAC EQUIPMENT, SEE
MECHANICAL DRAWINGS.
6.5 COORDINATE EXISTING CEILING WITH NEW
PARTITION.
0 2 4 8 NORTH
0 2 4 8 NORTH
0 2 4 8 NORTH
0 2 4 8 NORTH Scale: 1/4" = 1'-0"
IT & STORAGE DEMOLITION FLOOR PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM FLOOR PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM REFLECTED CEILING PLAN
Scale: 1/4" = 1'-0"
IT & STORAGE DEMOLITION REFLECTED CEILING PLAN
1.1 DEMOLISH EXISTING WALL.
2.1 REMOVE EXISTING FLOOR FINISH AND BASE.
PATCH ALL HOLES AND LEVEL UNEVEN SUBFLOOR.
2.2 EXISTING FLOOR FINISH TO REMAIN.
3.1 REMOVE EXISTING DOOR & FRAME, PREPARE
ROUGH OPENING AS REQUIRED FOR NEW DOOR.
4.2 REMOVE EXISTING SIGNAGE. RETAIN FOR REUSE.
6.4 EXISTING EXPOSED STRUCTURE.
6.6 REMOVE EXISTING LIGHTING, TYP. SEE
ELECTRICAL DRAWINGS.
6.8 DEMOLISH WALL MOUNTED HVAC EQUIPMENT, SEE
MECHANICAL DRAWINGS.
6.9 DEMOLISH EXISTING CABLE TRAY, SEE ELECTRICAL
DRAWINGS.
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
5070L
IC
E N
S E D A RC H I T ECT
DA
V ID J . REICHARD
NOR T H CA RO L I NA
ES
2.2
2.1
1.1
3.3
2.2
3.2
4.1
2.1
TR
104-2
102C-2
NOURISHMENT
PREP
102B-3
KITCHEN
CR-14-2
SERVICE
CORRIDOR
1.2
1.2
1.1 3.1
3.4 4.1
2.1
2.2
4.2
5.1
166 SF
104-2
TR
104-2 5.6
5.5
C6.0
C6.0
1.12.2
1.2
C6.0
102C-2
NOURISHMENT
PREP
102B-3
KITCHEN
5.45.4
5.4
5.5
CR-14-2
SERVICE
CORRIDOR
1.41.4
'-1
1"
11'-0"
5.3 5.3
6.4
A.F.F.8' - 0"
CEILING NOTES:
8'-0" A.F.F. EXISTING ACT
11'-7" A.F.F. BOTTOM OF CONCRETE
10'-7" A.F.F. BOTTOM OF BEAM
102C-2
NOURISHMENT
PREP
102B-3
KITCHEN
CR-14-2
SERVICE
CORRIDOR
6.8
6.7
6.7
6.9
6.2
6.1
6.2
6.3
6.46.5 104-2
TR
6.5
102C-2
NOURISHMENT
PREP
102B-3
KITCHEN
CR-14-2
SERVICE
CORRIDOR
Engineers Architects
# DEMOLITION KEY NOTES:
# NEW KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/6
/2
:5 0:
P
M C
:\U se rs \a pu lle n\ D oc um en ts
\A _2
2-
2-
VA
D ub lin E
H R
M -B ld g
2_ R
_a pu lle nV D
XT
7.
rv t
02.A-411
BUILDING 2, LEVEL A, TELECOM ROOM
104-2 PLANS
5 56ANP
EHRM INFRASTRUCTURE
UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027 NOVEMBER 8, 2024
100% BID DOCUMENTS
557-22-70022-192
DJR
Scale: 1/4" = 1'-0"
KITCHEN & TR DEMOLITION FLOOR PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM FLOOR PLAN
Scale: 1/4" = 1'-0"
KITCHEN & TR DEMOLITION REFLECTED CEILING PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM REFLECTED CEILING PLAN
1.1 DEMOLISH EXISTING WALL.
2.1 REMOVE EXISTING FLOOR FINISH AND BASE. PATCH
ALL HOLES AND LEVEL UNEVEN SUBFLOOR.
2.2 EXISTING FLOOR FINISH TO REMAIN.
3.2 REMOVE EXISTING DOOR & FRAME.
3.3 CREATE ROUGH OPENING FOR NEW DOOR.
4.1 REMOVE EXISTING SIGNAGE AND TURN OVER TO VA.
6.2 REMOVE EXISTING ACT CEILING, INCLUDING
ELECTRICAL, MECHANICAL, AND FIRE SUPPRESSION
FIXTURES. SEE ELECTRICAL AND MECHANICAL
DRAWINGS.
6.4 EXISTING EXPOSED STRUCTURE.
6.7 EXISTING CEILING TO REMAIN.
6.8 DEMOLISH WALL MOUNTED HVAC EQUIPMENT, SEE
MECHANICAL DRAWINGS.
6.9 DEMOLISH EXISTING CABLE TRAY, SEE ELECTRICAL
DRAWINGS.
0 2 4 8 NORTH
0 2 4 8 NORTH
0 2 4 8 NORTH
0 2 4 8 NORTH
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
1.1 NEW WALL, TYP. SEE A-506.
1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED AC
GRADE PLYWOOD BACK BOARDS IN TELECOM
ROOMS. PLYWOOD SHALL BE MOUNTED WITH A-SIDE
OUT. PAINT PLYWOOD BACK BOARDS P-2.
1.4 ALIGN WALLS
2.1 NEW FLOORING, INCLUDING UNDERLAYMENT, AND
RUBBER WALL BASE, SEE SPECS AND ROOM FINISH
SCHEDULE.
2.2 PATCH FLOORING TO MATCH EXISTING.
3.1 NEW DOOR & FRAME IN EXISTING MASONRY WALL,
SEE DOOR SCHEDULE.
3.4 NEW CARD READER, SEE ELECTRICAL DRAWINGS.
4.1 NEW ROOM SIGN, SEE SHEET A-602.
4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN
AGENT SIGN, SEE SHEET A-602.
5.1 INSTALL NEW SURFACE MOUNTED FIRE
EXTINGUISHER CABINET.
5.3 NEW CORNER GUARD.
5.4 NEW PAINT AND RUBBER WALL BASE TO MATCH
EXISTING.
5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO
MATCH EXISTING.
5.6 FLOOR TRANSITION AT STATIC DISSIPATIVE TILE TO
EXTEND FROM UNDERSIDE OF TELECOM ROOM TO
ADJACENT ROOM.
6.1 EXPOSED STRUCTURE
6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL
DRAWINGS.
6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.
6.4 WALL MOUNTED HVAC EQUIPMENT, SEE
MECHANICAL DRAWINGS.
6.5 COORDINATE EXISTING CEILING WITH NEW
PARTITION.
5070L
IC
E N
S E D A RC H I T ECT
DA
V ID J . REICHARD
NOR T H CA RO L I NA
ES
BILLING
212-2
OFFICE
212A-2
STORAGE
212B-2
209A-2
TR
3.1CORRIDOR
CR-21-2
2.1
BILLING
212-2
OFFICE
212A-2
STORAGE
212B-2
1.2
4.1
3.4
3.1
2.1
5.1
4.2
176 SF
209A-2
TR
209A-2
5.6
5.5
1.2
CORRIDOR
CR-21-2
7'-3"
'-4
BILLING
212-2OFFICE
212A-2
STORAGE
212B-2
6.4
209A-2
TR
CEILING NOTES:
11'-5" A.F.F. BOTTOM OF CONCRETE
10'-4" A.F.F. BOTTOM OF BEAM
6.5
CORRIDOR
CR-21-2
6.9
BILLING
212-2
OFFICE
212A-2
STORAGE
212B-2
6.2
6.3
6.4
209A-2
TR
CORRIDOR
CR-21-2
Engineers Architects
# DEMOLITION KEY NOTES:
# NEW KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/6
/2
:5 0:
P
M C
:\U se rs \a pu lle n\ D oc um en ts
\A _2
2-
2-
VA
D ub lin E
H R
M -B ld g
2_ R
_a pu lle nV D
XT
7.
rv t
02.A-421
BUILDING 2, LEVEL B, TELECOM ROOM
209A-2 PLANS
6 56ANP
EHRM INFRASTRUCTURE
UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027 NOVEMBER 8, 2024
100% BID DOCUMENTS
557-22-70022-192
DJR
Scale: 1/4" = 1'-0"
TELECOM ROOM DEMOLITION FLOOR PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM FLOOR PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM DEMOLITION REFLECTED CEILING PLAN
Scale: 1/4" = 1'-0"
TELECOM ROOM REFLECTED CEILING PLAN
2.1 REMOVE EXISTING FLOOR FINISH AND BASE.
PATCH ALL HOLES AND LEVEL UNEVEN
SUBFLOOR.
3.1 REMOVE EXISTING DOOR & FRAME, PREPARE
ROUGH OPENING AS REQUIRED FOR NEW DOOR.
6.4 EXISTING EXPOSED STRUCTURE.
6.5 REMOVE EXISTING ELECTRICAL, MECHANICAL &
FIRE SUPPRESSION FIXTURES. SEE ELECTRICAL
AND MECHANICAL DRAWINGS.
6.9 DEMOLISH EXISTING CABLE TRAY, SEE
ELECTRICAL DRAWINGS.
0 2 4 8 NORTH
0 2 4 8 NORTH
0 2 4 8 NORTH
0 2 4 8 NORTH
N
AREA OF WORK
KEY PLAN
SCALE: NO SCALE
1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED
AC GRADE PLYWOOD BACK BOARDS IN
TELECOM ROOMS. PLYWOOD SHALL BE
MOUNTED WITH A-SIDE OUT. PAINT PLYWOOD
BACK BOARDS P-2.
2.1 NEW FLOORING, INCLUDING UNDERLAYMENT,
AND RUBBER WALL BASE, SEE SPECS AND
ROOM FINISH SCHEDULE.
3.1 NEW DOOR & FRAME IN EXISTING MASONRY
WALL, SEE DOOR SCHEDULE.
3.4 NEW CARD READER, SEE ELECTRICAL
DRAWINGS.
4.1 NEW ROOM SIGN, SEE SHEET A-602.
4.2 NEW FIRE EXTINGUISHER FLAG SIGN AND CLEAN
AGENT SIGN, SEE SHEET A-602.
5.1 INSTALL NEW SURFACE MOUNTED FIRE
EXTINGUISHER CABINET.
5.5 PATCH WALL PAINT AND RUBBER WALL BASE TO
MATCH EXISTING.
5.6 FLOOR TRANSITION AT STATIC DISSIPATIVE TILE
TO EXTEND FROM UNDERSIDE OF TELECOM
ROOM TO ADJACENT ROOM.
6.2 NEW LIGHT FIXTURE, TYP. SEE ELECTRICAL
DRAWINGS.
6.3 CABLE TRAY, SEE ELECTRICAL DRAWINGS.
6.4 WALL MOUNTED HVAC EQUIPMENT, SEE
MECHANICAL DRAWINGS.
5070L
IC
E N
S E D A RC H I T ECT
DA
V ID J . REICHARD
NOR T H CA RO L I NA
STORAGE
BM101-3
LAB STORAGE
BM102-3
CORRIDOR
CRB1-3
STAIR C-2
STB1-3
2.2
3.1
4.1
3.3
2.1
EXISTING FEC
5.9
9' -8
STORAGE
BM101-3
LAB STORAGE
BM102-3
CORRIDOR
CRB1-3
STAIR C-2
STB1-3
1.2
BM101-3
1.2
3.4
5.4
2.2 1.1
3.1
2.1
3.1
4.1
12'-11"
4.1
5.6
5.5
5.5
EXISTING FEC
8' -8
9'
-8
113 SF
TR
BM101A-3
M4.1
1.2
5.14
BM101A-3
5.1
4.2
5.5
STORAGE
BM101-3
LAB STORAGE
BM102-3
CORRIDOR
CRB1-3
STAIR C-2
STB1-3
6.1
CEILING NOTES:
9'-0" A.F.F. EXISTING 1X1 ACT
11'-6" A.F.F. BOTTOM OF CONCRETE
10'-8" A.F.F. BOTTOM OF BEAM
6.7
A.F.F.9' - 0"
6.11
7.2
STORAGE
BM101-3
LAB STORAGE
BM102-3
CORRIDOR
CRB1-3
STAIR C-2
STB1-3
6.1 6.2
6.3
6.4 6.5
TR
BM101A-3
6.6
Engineers Architects
# DEMOLITION KEY NOTES:
# NEW KEY NOTES:
Revisions: Date
Drawing Title
Approved
Project Title
Location
VA PROJECT NUMBER
Building Number
Drawing Number
Dwg of
VA FORM 08-6231
Office of Construction and Facilities Management
CONSULTANTS: PROJECT MANAGER
Date Checked Drawn
FULLY SPRINKLERED
ACG Project Number
Headquarters:
Apogee Consulting Group, P.A.
1151 Kildaire Farm Road Cary, North Carolina 27511 www.acg-pa.com 919-858-7420 U.S. Department of Veterans Affairs# © COPYRIGHT Apogee Consulting Group, P.A.
/6
/2
:4 9:
A
M C
:\U se rs \a pu lle n\ D oc um en ts
\A _2
2-
2-
VA
D ub lin E
H R
M -B ld g
3_ R
_a pu lle nV D
XT
7.
rv t
03.A-401
BUILDING 3, LEVEL C, TELECOM ROOM
BM101A-3 PLANS
7 56ANP
EHRM INFRASTRUCTURE
UPGRADES
CARL VINSON VA MEDICAL CENTER
1826 VETERANS BLVD
DUBLIN, GA 31027 NOVEMBER 8, 2024
100% BID DOCUMENTS
557-22-70022-192
DJR
1.1 NEW WALL, TYP. SEE A-506.
1.2 PROVIDE 4’X8’X3/4” FIRE RETARDANT TREATED
AC GRADE PLYWOOD BACK BOARDS IN
TELECOM ROOMS. PLYWOOD SHALL BE
MOUNTED WITH A-SIDE OUT. PAINT PLYWOOD
BACK BOARDS P-2.
2.1 NEW FLOORING, INCLUDING UNDERLAYMENT,
AND RUBBER WALL BASE, SEE SPECS AND
ROOM FINISH SCHEDULE.
2.2 PATCH FLOORING TO MATCH EXISTING.
3.1 NEW DOOR & FRAME IN EXISTING MASONRY
WALL, SEE DOOR SCHEDULE.
3.4 NEW CARD READER,…