Attachment 18 - Contractor Safety - Environmental Form.docx

DOCX document 14 KB Posted

Attached to
36C77622B0029 - Replace Boilers - Leavenworth - Solicitation Federal contract opportunity
Solicitation number
36C77622B0029
Issued by
Department of Veterans Affairs Technology Acquisition Center Austin

About this file

This document includes a contractor safety and environmental record evaluation form and details of a federal solicitation for replacing boilers at a Department of Veterans Affairs medical center.

The evaluation form requests a contractor's OSHA 300 Form information over multiple years including man hours, cases involving days away from work or restricted activity, days away restricted or transferred rate, and any serious, willful or repeat OSHA violations in the last three years.

The solicitation seeks bids to award a firm-fixed-price contract for replacing four antiquated water tube boilers and associated piping and support systems with three new energy efficient fire tube boilers at the Dwight D. Eisenhower VA Medical Center in Leavenworth, Kansas. The project scope also includes replacing auxiliary systems in one building, fuel oil pump sets, condensate piping, a deaerator tank, condensate return tank, adding a continuous blowdown heat recovery package, and asbestos abatement of replaced piping. The solicitation was issued by the Department of Veterans Affairs Technology Acquisition Center Austin.

View the file

Other files for this federal contract opportunity

Other files attached to 36C77622B0029 - Replace Boilers - Leavenworth - Solicitation, newest first.
File Type Posted
Attachment 26 - RFIs - Technical Questions and Responses - REVISED.pdf PDF
36C77622B0029 0003.pdf PDF
36C77622B0029 0002.pdf PDF
Attachment 24 - RFIs - Technical Questions and Responses.pdf PDF
Attachment 22 - DDC for HVAC.pdf PDF
Attachment 23 - S-532 Drawing Sheet.pdf PDF
Attachment 21 - Asbestos Report.pdf PDF
Attachment 25 - Site Visit Attendance Sheet.pdf PDF
36C77622B0029 0001.pdf PDF
36C77622B0029_1.pdf PDF
Attachment 06 - Fire Protection - Drawings.pdf PDF
Attachment 08 - Mechanical - Part 1 - Drawings.pdf PDF
Attachment 09 - Mechanical - Part 2 - Drawings.pdf PDF
Attachment 12 - Security - Drawings.pdf PDF
Attachment 01 - General Information - Drawings.pdf PDF
Attachment 11 - Electrical - Part 2 - Drawings.pdf PDF
Attachment 15 - Specifications - Volume 3.pdf PDF
Attachment 16 - Boiler Plant - Drawing Sheet - M001.pdf PDF
Attachment 19 - Wage Rates - Leavenworth KS 5-21-2022.pdf PDF
Attachment 20 - VHA Supplemental Contract Requirements for Combatting COVID-19 Updated 12-14-2021.docx DOCX document
Attachment 02 - Hazardous Materials - Drawings.pdf PDF
Attachment 07 - Plumbing - Drawings.pdf PDF
Attachment 13 - Specifications - Volume 1.pdf PDF
Attachment 14 - Specifications - Volume 2.pdf PDF
Attachment 17 - Limitations on Subcontracting - Construction.docx DOCX document
Attachment 03 - Civil - Drawings.pdf PDF
Attachment 04 - Structural - Drawings.pdf PDF
Attachment 05 - Architectural - Drawings.pdf PDF
Attachment 10 - Electrical - Part 1 - Drawings.pdf PDF
Show all 29

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Contractor Safety and Environmental Record Evaluation Form

Information provide below is current and applicable to Solicitation 36C77621B0013 Company Name: ______________________________________________ Address: _____________________________________________________ Telephone: ______________________ Fax: ________________________ Email: _______________________________________________________ Contact: ______________________________________________________ Utilizing your OSHA 300 Forms, please complete the following information:

Category
2017
2018
2019
2020

Number of man hours (jobsite and office).

Number of cases involving days away from work, restricted activity, or both (Column H and I of OSHA 300).

Days away, restricted, or transferred rate (# of days away, restricted, or transferred cases x 200,000/# of man hours) (DART Rate).

Number of serious, willful, or repeat violations from OSHA within the last 3 years. Please attach explanation for any violations.

File details come from the government source that posted it. Updated .