Attachment 04 - Structural - Drawings.pdf
PDF 10 MB Posted
- Attached to
- 36C77622B0029 - Replace Boilers - Leavenworth - Solicitation Federal contract opportunity
- Solicitation number
- 36C77622B0029
About this file
This solicitation is for the replacement of four antiquated boilers and associated piping and support systems at the Dwight D. Eisenhower VA Medical Center in Leavenworth, Kansas. The Department of Veterans Affairs, through its Veterans Health Administration Program Contracting Activity Central, is seeking a single firm-fixed-price contract to design and implement the replacement of the existing water tube boilers with three new energy efficient fire tube boilers. Additional work includes replacing auxiliary systems in Building 39, fuel oil pump sets, condensate piping, deaerator tank, condensate return tank, and adding a Continuous Blowdown Heat Recovery Package, with asbestos abatement of all replaced piping. The solicitation number is 36C77622B0029 and responses are due through the Department of Veterans Affairs Technology Acquisition Center located in Austin, Texas.
View the file
Other files for this federal contract opportunity
Show all 29
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURAL
ABBREVIATIONS & NOTES
S-001
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t o n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t th re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006 Revisions: Date:
BID DOCUMENTS
NOTES
S-002
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006
1 92 3 4 5 6 7 8
A
B
0.1
C
V
IF
65' - 9 3/8"
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
18'-8"+/-
VIF
17'-9"+/-
VIF
15'-8"+/-
PORTIONS OF WALL
TO REMAIN (TYP)
/8
/4
/8
/8
/4
3 EXISTING
TRENCH
EXISTING CONCRETE
EQUIPMENT PADS;
TYP 1
TYP
TYP
VIF
8'-6"+/-
VIF
11'-0"+/-
VIF
19'-8"+/-
VIF
5'-9"+/-
V
IF
V
IF
V
IF
V
IF
20' - 11 3/4"
113' - 4 1/8"
VIF
21'-0"+/-
VIF
19'-0"+/-
TYPTYP
TYPTYP
V
IF
TYP 1
SD501
S
TO
R E
FR
O N T
2' - 0"
EXIST SLAB &
STRUCTURE
TO REMAIN
TYP
SD501
℄ EXIST ROOF
TRUSS (VIF)
℄ EXIST ROOF
TRUSS (VIF)
℄ EXIST ROOF
TRUSS (VIF)
℄ EXIST ROOF
TRUSS (VIF)
℄ EXIST ROOF
TRUSS (VIF)
℄ EXIST ROOF
TRUSS (VIF)
T
R U
SS
ES
EXISTING STORAGE
BOILER PLANT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
PLAN
NORTH
ACTUAL
NORTH
KEYPLAN
/1
/2
:3
:5
P
M
SD101
STRUCTURAL
DEMOLITION PLAN - BOILER ROOM
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
1/8" = 1'-0"
DEMOLITION PLAN - BOILER ROOM
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
2. FOR ADDITIONAL DEMOLITION, REFER TO ARCH, MECH,
ELEC, AND PLUMBING DWGS.
SHEET KEY NOTES
1 REMOVE EXISTING STAIRS.
2 REMOVE EXISTING PLATFORM POSTS.
3 REMOVE EXISITNG CONCRETE SLAB-ON-GRADE (HATCHED)
SLAB THICKNESS VERIFY IN FIELD (VIF).
4 REMOVE EXISITNG LOAD-BEARING WALLS PRIOR TO
DEMOLITION OF EXISTING WALL, PROVIDE TEMPORARY
SHORING OF EXISTING ROOF STRUCTURE. TEMPORARY
SHORING TO BE DESIGNED BY CONTRACTOR'S DELEGATED
DESIGN ENGINEER. SUBMIT SIGNED AND SEALED DRAWINGS
AND CALCULATIONS FOR RECORD.
5 REMOVE PORTION OF EXISTING MASONRY WALL, SEE DETAIL
3/SD501. INFILL PORTION OF MASONRY WALL AS SHOWN ON
SF101 PRIOR TO REMOVAL.
6 REMOVE EXISTING BOILERS AND PLATFORMS.
7 REMOVE EXISTING RAILINGS.
8 REMOVE EXISTING CONCRETE PADS.
9 REMOVE EXISTING PLATFORM AND FRAMING.
10 REMOVE EXISTING METAL WALL.
11 REMOVE EXISTING METAL FENCE.
12 REMOVE FULL OR PARTIALLY EXISTING BELOW GRADE BOILER
FOUNDATIONS.
13 SELECTIVELY DEMOLISH PIT SLAB FOR NEW SUMP. SEE SF101.
14 WALL FRAMING REFER TO ARCH DWGS.
PLAN NOTES:
1. FINISH SLAB ELEVATION DATUM SET TO [0.00'].
B
0.1
C
V
IF
65' - 9 3/8"
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
18'-8"+/-
VIF
17'-9"+/-
VIF
15'-8"+/-
TYP
VIF
8'-6"+/-
VIF
11'-0"+/-
VIF
19'-8"+/-
VIF
5'-9"+/-
V
IF
V
IF
6' - 7"
3' - 7"
VIF
21'-0"+/-
VIF
19'-0"+/-
TYPTYP
V
IF
4 5
TYP
SF401
TYP TYP
EXISTING STACK
EXISTING STORAGE
BOILER PLANT
10 10
10 10
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:3
:3
P
M
SD111
STRUCTURAL
DEMOLITION PLAN - UPPER PLATFORMS
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
1/8" = 1'-0"
DEMOLITION PLAN - UPPER
PLATFORMS
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
2. FOR ADDITIONAL DEMOLITION, REFER TO ARCH, MECH,
ELEC, AND PLUMBING DWGS.
SHEET KEY NOTES
1 REMOVE EXISTING STAIRS.
2 REMOVE EXISTING PLATFORM POSTS AND FRAMING.
3 REMOVE EXISITNG PLATFORM.
4 REMOVE EXISITNG EXTERIOR CONCRETE STAIR.
5 REMOVE EXISTING EXTERIOR POST.
6 REMOVE EXISTING CONCRETE WALKWAY AND FOUNDATIONS.
7 REMOVE EXISTING STEEL AND CONCRETE DUCT SUPPORT.
FILL HOLE W/COMPACTED SOIL.
8 REMOVE EXISTING EQUIPMENT, EMBEDMENTS, AND
ASSOCIATED CONCRETE CURBS AND PADS (VIF). SEE SF111
FOR REPAIR.
9 REMOVE DOOR OPENING. REFER TO ARCH DWGS.
10 REMOVE PORTION OF EXISTING WALL FOR MEP
PENETRATION.
11 REMOVE EXISTING SLAB-ON-GRADE.
B
0.1
C
EXIST STEEL JOIST
FRAMING TO REMAIN
(TYP)
V
IF
65' - 9 3/8" 20' - 11 7/8"
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
18'-8"+/-
VIF
17'-9"+/-
VIF
15'-8"+/-
VIF
21'-0"+/-
VIF
19'-0"+/-
V
IF
EXTERIOR WALLEDGE OF EXISTING ROOF
EXISTING TRUSS,
TO REMAIN (TYP)
REMOVE EXISTING STEEL
CEILING BEAMS AS SHOWN;
APPROX EL=22'-10" AFF
(TYP)
EXISTING STACK
EXISTING STORAGE
BOILER PLANT
EXISTING CUPOLA
ABOVE; REMOVE EXIST
LOUVERS AS SHOWN
ON MECH DWGS
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:3
:4
P
M
SD112
STRUCTURAL
DEMOLITION PLAN - UPPER CEILING
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
1/8" = 1'-0"
DEMOLITION PLAN UPPER CEILING
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
2. FOR ADDITIONAL DEMOLITION, REFER TO ARCH, MECH,
ELEC, AND PLUMBING DWGS.
DEMOLITION
SECTIONS & DETAILS
SD501
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006
UP
A
B
0.1
C
/8
/8
65' - 9 3/8" 20' - 11 7/8"
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
18'-8"+/-
VIF
17'-9"+/-
VIF
15'-8"+/-
FOOTING, TYP; SEE
FND SCHEDULE
1' - 1"
SUMP PIT; REFER TO MEP DWGS;
SEE DETAIL 10/S-510
6' - 3"15' - 1"12' - 7"
PUMP
PIT
FOOTING, TYP;
SEE FND SCHEDULE
W 14X109
C O
LU
M N
H S
S X
X
.2
C O
L U
M N
T Y P
F4 F4 F4 F5 F6
F1 F2
F2
[ -1.5' ] [ -1.5' ] [ -1.5' ] [ -2.5' ] [ -2.5' ]
F3[ -1.0' ] [ -1.0' ]
[ -1.0' ]
S-501
S-501
S-501
3' - 9"
[ -1.0' ]
11' - 4"
2'-8" SQ x 2'-0" DEEP SUMP PIT;
REFER TO MEP DWGS; SEE DETAIL
4/S-510, SIM
6' - 5" W
14X109
C O
LU
M N
W 14X109
C O
LU
M N
W 14X109
C O
LU
M N
W 14X109
C O
LU
M N
W 14X109
C O
LU
M N
CF23
EXISTING STORAGE
BOILER PLANT
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:1
:5
A
M
SF1B1
STRUCTURAL
FOUNDATION PLAN
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
1/8" = 1'-0"
FOUNDATION PLAN
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
PLAN NOTES:
1. F# INIDICATES FOUNDATION TYPE, SEE S-501 FOR
FOUNDATION SCHEDULE.
2. [#.#'] INDICATES TOP OF FOOTING ELEVATION.
1 92 3 4 5 6 7 8
A
B
/8
/8
65' - 9 3/8" 20' - 11 7/8"
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
18'-8"+/-
VIF
17'-9"+/-
VIF
15'-8"+/-
0.1
C
6 66 66
7 7555
(TYP)
(TYP)
2A
2B
(TYP)
10 10
772A 715
S-511
S-511
(TYP)
(TYP)
PUMP
PIT
8' - 4"
8' - 0"
8' - 0"
2' - 8 3/8"
/4
6' - 5"
6' - 5"
2' - 11"
4' - 4"
5' - 0"
(TYP)
1' - 0 1/4"
1' - 10 1/2"12' - 0"
1' - 9 3/4"2' - 4 1/2" 14' - 0"1' - 11 3/8"14' - 0"3' - 0 1/4"2' - 3 3/4"14' - 0"2' - 8 1/2"
18 (TYP)
EXIST SLAB &
STRUCTURE
TO REMAIN
1,2,3
S-512
(T
YP
2B
S-501
S-512
S-512
(TYP)
(TYP)
S-510
EXISTING STORAGE
BOILER PLANT 23
S-511
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:4
:1
A
M
SF101
STRUCTURAL
FRAMING PLAN - BOILER ROOM
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
2. FOR ADDITIONAL INFORMATION, REFER TO ARCH, MECH,
ELEC, AND PLUMBING DWGS.
SHEET KEY NOTES
1 HSS6x6x1/4 STEEL MEZZANINE POST.
2A STEEL STAIR, REFER TO ARCH DWGS.
2B STEEL STAIR.
3 INFILL EXISTING WALL OPENING WITH BRICK, TOOTH-IN BRICK.
4 NEW WALL OPENING, SEE DETAIL 3/SD501.
5 OVERHEAD DOOR AND LINTEL, REFER TO ARCH DWGS, SEE
DETAIL 1/S-512.
6 W14x109 STEEL COLUMN.
7 EXTERIOR MASONRY WALL FULLY-GROUTED, REFER TO ARCH
DWGS.
8 CONCRETE EQUIPMENT PAD, COORDINATE SIZE AND LOCATION
WITH FINAL MEP EQUIPMENT SELECTION, SEE DETAIL 6/S-510.
9 UTILITY TRENCH WITH STEEL GRATING, REFER TO MEP DWGS,
SEE DETAIL 4/S-510.
10 W8x40 BOILER RAILS. COORDINATE LOCATION WITH MECH EQUIP, DETAIL SEE 7/S-510.
11 12" THICK REINFORCED CONCRETE SLAB-ON-GRADE WITH
INTEGRAL TRENCHES. #4 @12" EW, T&B.
12 6" THICK REINFORCED CONCRETE SLAB-ON-GRADE. #4 @12" EW,
TOP.
13 4" PLATFORM PIPE POST, SEE DETAIL 1/S-520.
14 CMU CONTROL ROOM WALL. COORDINATE WITH ARCH DWGS.
15 THICKENED SLAB AT STAIR LANDING, SEE DETAIL 9/S-510.
16 SUMP PIT IN EXISTING SLAB. REFER TO MEP DWGS, SEE DETAIL
10/S-510.
17 SHIP LADDER, OSHA STANDARD.
18 THICKENED SLAB AT CMU WALL, SEE DETAIL 1/S-511.
19 INTERCEPTOR, REFER TO PLUMBING DRAWINGS.
20 FLOOR DRAIN REFER TO PLUMBING DWGS.
21 SUMP PIT, SEE DETAIL 4/S-510, SIM.
22 ANTI-RAM BOLLARDS. SEE 2/S-530 AND REFER TO CIVIL DWG
C-102.
23 NEW RAILINGS, SEE DETAIL 9/S-511.
24 L3X3X3/8 DIAGONAL BRACING ALL SIDES. SEE SIM 1/S-521.
1/8" = 1'-0"
FRAMING PLAN - BOILER ROOM
PLAN NOTES:
1. FINISH SLAB ELEVATION DATUM SET TO [0.00'].
2. STEEL GRATING TO BE 19-W-4, 1"x3/16". HOT-DIP GALVANIZED
AFTER FABRICATION.
3. ALL STEEL FINISH TO BE SHOP-PRIMED. ALL RAILINGS AND
STAIR NOSINGS TO BE FIELD-PAINTED SAFETY YELLOW.
4. CONCRETE EQUIPMENT PAD TO BE 4" THICK UNLESS NOTED
OTHERWISE.
DN
DNDNDN
DN
DN
S-302
SF401
1 92 3 4 5 6 7 8
A
B
0.1
C
SF401
W10 TYP;
PLAN
NOTE 1
W10; PLAN NOTE 1
TYP
3' - 6"
65' - 9 3/8" 20' - 11 3/4" 19' - 0 1/4" 18' - 11 5/8" 18' - 2 1/4" 19' - 10" 18' - 7 3/4" 17' - 9" 15' - 7 7/8"
/8
/8
12' - 6" 0' - 8"
3' - 9"1
1' - 0"
W12X19
W X
W X
W X
W X
W X
W X
W12X19
W16X31
W12X19
W12X19 W
X
W X
W X
W X
W X
W12X19 W12X19
W X
W X
W X
W X
W X
W X
W X
W X
C X
.7
W12X19W12X19W12X19
W12X19
EXISTING STACK
EXISTING STORAGE
TRANSFORMER ROOM GENERATOR ROOM
EXISTING STORAGE
BOILER PLANT
13' - 10 3/4"
12' - 8 3/4"
13' - 10 3/4"
POST UP (4 TYP) TO PLAT-
FORM ABOVE; SEE 1/SF401
15' - 1 1/2"
2' - 0"
1' - 0"
1' - 0 3/4" 11' - 5" 3' - 4" 6' - 0" 4' - 8"
/2
11' - 1 5/8"
27' - 7" 6' - 3 7/8" 11' - 4 1/8"
5' - 3"
SOD
14' - 0"
5' - 0"
BOILER BELOW; REFER TO MECH DWGS
S-511
S-511
8' - 2 1/2"
W X
S-520
/2
(TYP)
0' - 10"6' - 2"
SF401
/4
S-520
POCKET CONN
PLATFORM ABOVE;
SEE 1/SF401
W X
W12X19
W X
W12X19
S-520
S-520
(TYP)
12' - 8 3/4"
13' - 10 3/4"
SOD
W10 (TYP)
PLAN NOTE 6
(TYP)
(TYP)
SF401
SIM
S-521
S-301
(TYP)
W X
W X
W X
W X
C X
.7
C12X20.7
S-510
S-501
S-501
S-501
CF18
/2
6' - 4"
(TYP)
13 13
6" SOG W/#4 @12"
EW
(TYP)
(TYP)
15 14
4' - 0"
D N
20 18 19
C F
15' - 1 1/2"
W X
W12X19
W X
W12X19
W12X19
3' - 6 1/2" 2' - 2"
13' - 5 3/8"
13' - 5 3/8"
W X
W X
W8X15
D O O R
5' - 2"
W X
W X
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:0
:1
A
M
SF111
STRUCTURAL
FRAMING PLAN - UPPER OFFICE & BOILER
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
2. FOR ADDITIONAL INFORMATION, REFER TO ARCH, MECH,
ELEC, AND PLUMBING DWGS.
1/8" = 1'-0"
FRAMING PLAN - UPPER OFFICE &
BOIILER
PLAN NOTES:
1. W10 INDICATES W10x17.
2. SOD INIDCATES LOCATION AND SPAN OF 2-1/2" LIGHTWEIGHT
CONCRETE SLAB ON 1-1/2", 20 GA COMPOSITE METAL DECK
(4" TOTAL THICKNESS).
3. INDICATES SPAN DIRECTION.
4. STEEL GRATING TO BE 19-W-4, 1"x3/16".
5. ALL STEEL FINISH TO BE SHOP-PRIMED. ALL RAILINGS AND
STAIR NOSINGS TO BE FIELD-PAINTED SAFETY YELLOW.
6. ALL STEEL GRATING HORIZONTAL BEAMS ARE W10X17
UNLESS NOTED OTHERWISE.
7. CONCRETE EQUIPMENT PAD TO BE 4" THICK UNLESS NOTED
OTHERWISE.
8. INDICATES L3x3x3/8 KNEE BRACE.
SHEET KEY NOTES
1 HSS6x6x1/4 STEEL MEZZANINE POST.
2 STEEL STAIR. REFER TO ARCH DWGS.
3 STEEL STAIR WITH 1" GRATING TREADS, SEE DETAIL 4/S-520.
4 CONCRETE EQUIPMENT PAD, COORDINATE SIZE WITH FINAL
MEP EQUIPMENT SELECTION. SEE DETAIL 6/S-510.
5 4" PLATFORM PIPE POST, SEE DETAIL 1/S-520.
6 KNEE BRACE.
7 PERIMETER GUARD RAILING AROUND CATWALKS AND
PLATFORMS AS SHOWN.
8 LADDER. SEE DETAIL 7/S-520.
9 STEEL GRATING CATWALK & PLATFORM.
10 3'-0" SPRING SAFETY GATE.
11 HOIST BEAM AND TROLLEY. SEE DETAIL 1/SF401.
12 PIPE SUPPORT HANGERS ABOVE, SEE DETAIL 1/SF402.
13 HSS6x6x1/4 STEEL ROOF POST ON THICKENED SLAB UNDER
POSTS, SIM 1/S-511.
14 INFILL ABANDONED CHIMNEY OPENING, TOP AND BOTTOM, SEE
S-532.
15 REMOVE EXISTING CURB/PAD. INSATLL STONE AND CIP SLAB-
ON-GRADE, SEE DETAIL 11/S-501.
16 PROVIDE MASONRY WALL ENCLOSURE. REFER TO TO ARCH
DWGS.
17 INFILL OVERHEAD DOOR AND DOUBLE MAN DOOR WITH CMU.
REFER TO ARCH DWGS.
18 INFILL OPENING WITH CMU.
19 PROVIDE LINTEL AND GIRT AT LOUVER OPENING, SEE DETAILS
7,8/S-522.
20 PROVIDE LINTEL AT MEP PENETRATION, SEE DETAIL 7/S-522.
21 PROVIDE 6" CONCRETE SLAN-ON-GRADE W/#4 @12" EW.
22 THICKENED SLAB AT CMU WALL, SEE DETAIL 1/S-511.
23 LANDING PLATFORM WITH 1" GRATING ON W12X19 BEAMS WITH
4" DIA PIPE POSTS.
24 CONCRETE STAIR LANDING PAD. SEE 4/S-521.
S-302
1 92 3 4 5 6 7 8
A
B
SF401
VIF
21'-0".
VIF
19'-0".
VIF
19'-0".
VIF
19'-0".
VIF
19'-0".
VIF
18'-8"+/-
VIF
17'-9"+/-
VIF
15'-8"+/-
PLATFORM POST
UP FROM BELOW
(TYP) NOTE 4
MEP PIPE HANGER (TYP),
PLAN NOTE 1
W8X15 SUPPLEMENTAL
SUPPORT FRAMING (TYP),
PLAN NOTE 2
HSS4X0.25 PIPE POST &
W8X15 HEADER BEAM (TYP),
PLAN NOTE 3
23' - 4"23' - 4"
24' - 2"
26' - 4"
26' - 4"
23' - 4"
26' - 3"
23' - 4"23' - 4"
24' - 2"24' - 2"
23' - 4" 23' - 4" 23' - 4"
23' - 4"23' - 4"
23' - 4"
23' - 4"
23' - 4"
EXISTING ROOF
TRUSS, VIF (TYP)
(2)C10X15.3
(2)C10X15.3
(2)C10X15.3
W10X17
W10X17
(2 )C
X15
.3
(2)C10X15.3
EXISTING ROOF
TRUSS, VIF (TYP)
(2 )C x .3
SUPPLEMENTAL SUPPORT
FRAMING, ATTACH TO
EXISTING TRUSS (TYP)
SEE SIM 5/S-522
STANDARD WALL
CONNECTION
SUPPLEMENTAL SUPPORT
FRAMING, ATTACH TO
EXISTING TRUSS (TYP)
SEE SIM 5/S-522
SUPPORT POST
UP TO CUPOLA
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:3
:5
P
M
SF112
STRUCTURAL
FRAMING PLAN - PIPE HANGERS UPPER
BOILER
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
1/8" = 1'-0"
FRAMING PLAN - PIPE HANGERS
PLAN NOTES:
1. INDICATES MEP PIPE HANGER LOCATIONS. REFER TO
MECHANICAL DWGS.
2. INDICATES W8X15 SUPPLEMENTAL FRAMING. T/STL EL = 21'-0"
AFF UNLESS NOTED OTHERWISE.
3. PIPE POST BASE AT EL = 21'-0" AFF. POST LOCATIONS SHOWN ON
PLAN ARE APPROXIMATE AND SHALL BE COORDINATED WITH MEP
DWGS. TOP OF PIPE POST EL SHALL BE COORDINATED WITH MEP
EQUIPMENT CLEARANCES. REFER TO MEP DWGS. SEE 4/S-522.
4. PLATFORM POST FROM BELOW, TOP OF POST EL = 21'-0" AFF UNLESS
NOTED OTHERWISE. SEE SF101 & SF111.
B
0.1
C
EXISTING STACK
NOTE: FOR CUPOLA
ABOVE SEE SF122
EXIST WOOD
JOIST (TYP)
EXIST STEEL JOIST
FRAMING (TYP)
E X
IS
T
IN
G
K
B
A R
J O
IS
T
O C
V
IF
(T
Y P
2' - 8" 2' - 8"
1 1 1 12 2 2 2
EXISTING WOOD
JOISTS, VIF (TYP)
V
IF
65' - 9 3/8" 20' - 11 7/8"
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
18'-8"+/-
VIF
17'-9"+/-
VIF
15'-8"+/-
VIF
21'-0"+/-
VIF
19'-0"+/-
V
IF
SF401
S-302
SF4013
EXTERIOR
WALLEDGE OF
EXISTING ROOF,
VIF
EXISTING TRUSS,
VIF (TYP)
S-301
TYP
TYP
C X
.5
C X
.5
W12X26
W12X26
C X
.5
C X
.5
TYP
(C O
N T
(C O
N T
(C O
N T
(C O
N T
1,2,3
S-512
(T
YP
55 5 5 5
TYP
TYP
W12X19
W X
W X
(2)C8X11.5
SILNCER, REFER TO
ELEC DWGS
S-522
S-522
S-522
SF121
S-512
S-512
W8X15
W X
W8X15 W X
EXISTING UPPER ROOF JOIST
UPPER OFFICE STAIRWELL ROOF
SF121
SPAN OF 2 1/2" LW CONC SLAB
ON 1 1/2" 20 GA COMPOSITE
DECK (4" TOTAL THICKNESS)
EXIST MASONRY WALL
MASONRY WALL,
SEE 7/S-511; REFER
TO ARCH DWGS
4X4X3/8" LEDGER
S-511
S-511
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:3
:4
P
M
SF121
STRUCTURAL
FRAMING PLAN - ROOF
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
1/8" = 1'-0"
FRAMING PLAN - ROOF
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
2. FOR ADDITIONAL INFORMATION, REFER TO ARCH, MECH,
ELEC, AND PLUMBING DWGS.
SHEET KEY NOTES
1 SUPPORT EXISTING TRUSS ON STEEL COLUMN.
2 STEEL KNEE BRACE.
3 ROOF PENETRATION, REFER TO MEP DRAWINGS FOR SIZE
AND LOCATIONS. PROVIDE WOOD FRAMING AROUND
OPENING, SEE DETAIL 1/S-522.
4 EXISTING WOOD ROOF GIRDER AND JOISTS SHOWN ARE
IMPLIED ONLY AND MUST BE VERIFIED IN THE FIELD.
5 W12X26 TIE BEAM. SEE DETAILS ON SHEET S-512.
6 1 1/2" 20 GA TYPE B METAL ROOF DECK.
7 INFILL OPENING WITH CMU.
8 SILENCER STEEL SUPPORT FRAMING. SEE 1/ SF122 AND
REFER TO MECH DWGS.
3/16" = 1'-0"
SECTION
1/4" = 1'-0"
UPPER OFFICE STAIRWELL ROOF
SF122
1 92 3 4 5 6 7 8
A
B
0.1
C
1TYP
(2) W8X13 (HORIZONTAL)
(2) W8X13 (HORIZONTAL)
(2) W8X13 (HORIZONTAL)
(2) W8X13 (HORIZONTAL)
(2) W8X13 (HORIZONTAL)
(2) W8X13 (HORIZONTAL)
V
IF
65' - 9 3/8" 20' - 11 7/8"
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
19'-0"+/-
VIF
18'-8"+/-
VIF
17'-9"+/-
VIF
15'-8"+/-
VIF
21'-0"+/-
VIF
19'-0"+/-
V
IF
S-302
SF401
S-301
3 GUY WIRE
ANCHOR (TYP)
GUY WIRE
(TYP)
EXISTING STACK
TRANSFORMER ROOM GENERATOR ROOM
EXISTING STORAGE
BOILER PLANT
4' - 0 1/8"
A.7 A.6 A.5
LOUVER
HORIZ FRAME
EXIST
STEEL
ANGLE
SF122
3/8" PLATE
W8X13
EXIST TRUSS MEMBER
EXIST GUSSET
1/4
1/4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:3
:0
P
M
SF122
STRUCTURAL
FRAMING PLAN - ROOF CUPOLA
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
1/8" = 1'-0"
FRAMING PLAN - ROOF CUPOLA
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
SHEET KEY NOTES
1 STEEL FRAME
2 ROOF PENETRATION, REFER TO MEP DRAWINGS FOR SIZE
AND LOCATIONS. PROVIDE WOOD FRAMING AROUND
OPENING.
3 PROVIDE GUY-WIRE ANCHOR AND GUY-WIRE.
SEE DETAIL 4/S-512. GUY WIRE NUMBER AND LOCATION TO BE
COORDINATED WITH STACK MANUFACTURER'S FINAL DESIGN.
DESIGN AND DETAILING OF GUY WIRES ARE BY THE
CONTRACTOR'S DELEGATED DESIGN ENGINEER.
4 SILENCER SUPPORT FRAMING. SEE 1/ SF112 AND REFER TO
MECH DWGS.
3/8" = 1'-0"
SECTION AT CUPOLA
1 1/2" = 1'-0"
LOUVER GIRT CONNECTION DETAIL
1'-95_
9'-0 5_
10'-11"
4'-7 7_ 8"
10'-6"
1'-3 15__
2'-1 1_
3 5__
6"
2'-83_
1'-10 1_
7_
14'
3 5__
6"
7_
16'-5 1_
DN
DN
SF401
5 6 7
SF401
12' - 8 3/4"
13' - 10 3/4"
3' - 2" 4' - 11" 3' - 4"
/4
/4
1" STEEL GRATING
SPAN (TYP)
PERIMETER GUARD RAILING
AROUND PLATFORM
(TYP)
LADDER (TYP);
SEE 7,8/S-520
22' - 3"
SF401
20' - 2"
13' - 10 3/4"
KNEE BRACE
(TYP)
2L3X3L3/8"
DIAGONAL BRACE
(TYP)
HOIST BEAM
HOIST TROLLEY , ATTACH TO
BOTTOM FLANGE
21' - 0"
SF401
W X
W8X15
W X
W X
W8X15
SILENCER SUPPORT
POST UP TO CUPOLA;
SEE 5/SF401
H S S 4X
0.
(T
YP)
W X
W8X15
W8X15
SF401
A B
CATWALK MID
13' - 10 3/4"
CATWALK UPPER
22' - 3"
6 7
SF401
CATWALK MID
13' - 10 3/4"
CATWALK UPPER
22' - 3"
S-302
CATWALK UPPER
LEVEL 3
13' - 10 3/4"
/4
(2)L3X3L3/8" DIAGONAL
BRACING 4 SIDES (TYP)
EXIST OFFICE
LEVEL 2
21' - 0"
CATWALK LOW
12' - 8 3/4"
STEEL GIRT
CUPOLA
SILENCER, REFER TO
MECH DWGS
T/SUPPLEMENTAL
FRAMING; EL 21'-0"
SILENCER SUPPORT
FRAMING
SUPPORT POST
2L3X3L3/8"
DIAGONAL BRACE
ALL SIDES (TYP)
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
ACTUAL
NORTH
KEYPLAN
/1
/2
:3
:2
P
M
SF401
STRUCTURAL
ENLARGED PARTIAL FRAMING PLANS &
ELEVATIONS
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER DSProject Number
BID DOCUMENTS
1/4" = 1'-0"
FRAMING PLAN - CATWALK UPPER
DEAREATOR PLATFORM
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
1/4" = 1'-0"
ELEVATION
1/4" = 1'-0"
ELEVATION
1/4" = 1'-0"
ELEVATION
PLAN NOTES:
1. INDICATES SPAN DIRECTION.
2. STEEL GRATING TO BE 19-W-4, 1"x3/16".
3. ALL STEEL FINISH TO BE SHOP-PRIMED. ALL RAILINGS TO BE
FIELD-PAINTED SAFETY YELLOW.
4. ALL STEEL GRATING HORIZONTAL BEAMS ARE W8X15
UNLESS SHOWN OTHERWISE.
Revisions: Date:
1/4" = 1'-0"
ELEVATION
T.O. CLERESTORY
42' - 8"
B.O. TRUSS
22' - 10 1/2"
2 3 4 5 6
S-302
GUY WIRE
(TYP)
GUY WIRE
GUY WIRE
(TYP)
EXHAUST STACK
REFER TO MECH
DWGS (TYP)
EXIST ROOFLINE
(TYP)
EXIST STEEL ROOF
FRAMING (TYP)
EXIST STEEL ROOF
JOIST (TYP)
GUY WIRE ANCHOR
(TYP)
GUY WIRE
(TYP)
EXIST OFFICE
LEVEL 2
21' - 0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
/1
/2
:3
:3
P
M
S-301
STRUCTURAL
SECTIONS
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER RPProject Number
BID DOCUMENTS
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
1/4" = 1'-0"
SECTION
SHEET KEY NOTES
1 PROVIDE GUY-WIRE ANCHOR AND GUY-WIRE.
SEE DETAIL 4/S-512. GUY WIRE NUMBER AND LOCATION TO BE
COORDINATED WITH STACK MANUFACTURER'S FINAL DESIGN.
DESIGN AND DETAILING OF GUY WIRES ARE BY THE
CONTRACTOR'S DELEGATED DESIGN ENGINEER.
AB
S-301
GUY WIRE
(TYP)
GUY WIRE ANCHOR
(TYP)
4 5
CATWALK UPPER
LEVEL 3
13' - 10 3/4"
SF401
PIPE HANGER,
ATTACH TO WF BEAM
REFER TO MEP DWGS
WF HEADER BEAM,
SEE PLAN
SUPPLEMENTAL
SUPPORT FRAMING
PIPE POST, SEE PLAN
EXIST OFFICE
LEVEL 2
21' - 0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
/1
/2
:3
:1
P
M
S-302
STRUCTURAL
SECTIONS & ELEVATIONS
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 ER RPProject Number
BID DOCUMENTS
1/4" = 1'-0"
Section
GENERAL SHEET NOTES
1. FOR GENERAL STRUCTURAL NOTES SEE DRAWING S-001
AND S-002.
SHEET KEY NOTES
1 PROVIDE GUY-WIRE ANCHOR AND GUY-WIRE.
SEE DETAIL 4/S-512. GUY WIRE NUMBER AND LOCATION TO BE
COORDINATED WITH STACK MANUFACTURER'S FINAL DESIGN.
DESIGN AND DETAILING OF GUY WIRES ARE BY THE
CONTRACTOR'S DELEGATED DESIGN ENGINEER.
1/2" = 1'-0"
TYPICAL PIPE HANGER SUPPORT
ELEVATION
COL COL
FOUNDATIONS
SECTIONS & DETAILS
S-501
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 Revisions: Date:
BID DOCUMENTS
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
Mechanical, Electrical, Plumbing, & Structural Engineering
MR PROJECT NO: 0509-0006
CONCRETE SLAB
SECTIONS & DETAILS
S-510
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006
CONCRETE SLAB
SECTIONS & DETAILS
S-511
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 Revisions: Date:
BID DOCUMENTS
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
Mechanical, Electrical, Plumbing, A
A
COL
STRUCTURAL
SECTIONS & DETAILS
S-512
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-20 Revisions: Date:
BID DOCUMENTS
Miller-Remick LLC
1010 KINGS HIGHWAY SOUTH
CHERRY HILL, NEW JERSEY 08034
PHONE: (856)429-4000
FAX: (856)429-5002
Mechanical, Electrical, Plumbing, PLATFORMS & MEZZANINE
SECTIONS & DETAILS
S-520
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006 Revisions: Date:
BID DOCUMENTS
STRUCTURAL
PLATFORMS & MEZZANINE
SECTIONS & DETAILS
S-521
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006 Revisions: Date:
BID DOCUMENTS
STRUCTURAL
SECTIONS & DETAILS
S-522
DSER
SITE
SECTIONS & DETAILS
S-530
DSER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006
FUEL STORAGE TANK FOUNDATION
S-531
RPER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006
CHIMNEY MODIFICATIONS
S-532
RPER
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
A
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD MILLER-REMICK LLC
PROFESSIONAL ENGINEERCONSULTANT
321 4 5 6 7 8 9 10
PRINTS OF THIS DRAWING SHALL NOT BE USED FOR
ANY PURPOSE WHATSOEVER WITHOUT THE SEAL AND
SIGNATURE OF THE PROFESSIONAL ENGINEEER
MR PROJECT NO:
o n e e ig h th in c h o n e fo o t o n e q u a rt e r in c h o n e fo o t th re e e ig th s in c h o n e fo o t o n e h a lf in c h o n e fo o t th re e q u a rt e r in c h o n e fo o t n e in c h o n e fo o t n e a n d o n e h a lf in c h o n e fo o t re e in c h o n e fo o t
REPLACE BOILERS
IN BUILDING 39
DWIGHT D. EISENHOWER VA MEDICAL
CENTER - LEAVENWORTH, KS
589A6-19-204
2022-01-200509-0006
| S-001 |
| S-001 |
| S-001 |
| S-002 |
| S-002 |
| S-002 |
| SD101 |
| SD111 |
| SD112 |
| SD501 |
| SD501 |
| SD501 |
| SF1B1 |
| SF101 |
| SF111 |
| SF112 |
| SF121 |
| SF122 |
| SF401 |
| S-301 |
| S-302 |
| S-501 |
| S-501 |
| S-501 |
| S-510 |
| S-510 |
| S-510 |
| S-511 |
| S-511 |
| S-511 |
| S-512 |
| S-512 |
| S-512 |
| S-520 |
| S-520 |
| S-520 |
| S-521 |
| S-521 |
| S-521 |
| S-522 |
| S-522 |
| S-522 |
| S-530 |
| S-530 |
| S-530 |
| S-531 |
| S-531 |
| S-531 |
| S-532 |
| S-532 |
| S-532 |
File details come from the government source that posted it. Updated .