Attachment_11_-_SOW_Appendix_E_Asbestos_and_Lead_Inspection_Report.pdf
PDF 1 MB Posted
- Attached to
- YUMA AREA OFFICE ROOF REPAIRS
- Solicitation number
- 140R3025R0013
About this file
This document is an Asbestos and Lead Inspection Report prepared by Nicklaus Engineering, Inc. for the Bureau of Reclamation located at 7301 Calle Agua Salada in Yuma, Arizona. The inspection, conducted on March 11, 2024, involved comprehensive sampling and analysis of various roofing and acoustical tile materials from multiple buildings, including an admin building, desalting facility, admin trailer, and switch yard building.
The laboratory analysis, performed by Fiberquant Analytical Services using Polarized Light Microscopy (PLM), examined 18 samples across different material types such as white and grey roofing, white roofing membranes, and 2x4 acoustical ceiling tiles. The key finding is that no Asbestos Containing Materials (ACM) or Lead Based Paint (LBP) were detected in any of the samples. The inspection followed ASTM Standard E 2356-04 and was conducted by AHERA certified inspectors, with the laboratory being accredited by the National Voluntary Laboratory Accreditation Program (NVLAP).
View the file
Other files
Show all 34
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Nicklaus Engineering, Inc.
Asbestos and Lead Inspection Report
Bureau of Recalamation 7301 Calle Agua Salada Yuma, AZ 85364
Prepared for:
David A. Walker Environmental Protection Specialist dgwalker@usbr.gov
Submitted by:
Nicklaus Engineering Inc.
1851 W. 24th Street Yuma, AZ 85364
NEI Project No. 024-0064
March 2024
Nicklaus Engineering, Inc.
Table of Contents
1.0 ACRONYMS AND ABBREVIATIONS
2.0 EXECUTIVE SUMMARY
3.0 PROJECT LIMITATIONS
4.0 INSPECTION PROCEDURES
5.0 ANALYTICAL RESULTS
6.0 QUALITATIVE ASSESSMENT OF ACM
7.0 QUALIFICATIONS
8.0 CONDITIONS AND LIMITATIONS
9.0 LIST OF ATTACHMENTS
Nicklaus Engineering, Inc. 1
1.0 ACRONYMS AND ABBREVIATIONS
AC Air Conditioning ACM Asbestos Containing Material AHERA Asbestos Hazard Emergency Response Act of 1986 ASTM American Society for Testing and Materials EPA Environmental Protection Agency HVAC Heating Ventilating and Air Conditioning LBP Lead Based Paint NEI Nicklaus Engineering, Inc.
NESHAP National Emissions Standard for Hazardous Air Pollutants NIST National Institute of Standards and Technology NVLAP National Voluntary Laboratory Accreditation Program OSHA Occupational Safety and Health Administration PLM Polarized Light Microscopy RACM Regulated Asbestos Containing Material SF Square Feet XRF X-Ray Fluorescence
Nicklaus Engineering, Inc. 2
2.0 EXECUTIVE SUMMARY
Nicklaus Engineering Inc. has performed this asbestos and lead-based paint inspection at 7301 Calle Agua Salada, Yuma, AZ 85364. This inspection included:
• Site Inspection
• Sample Preparation
• Sample Collection
• Laboratory Analysis
• Analytical Review
• Final Report Preparation
Based upon the information obtained during the asbestos inspection, considering the limitations contained within Section 3.0, this asbestos inspection has revealed no Asbestos Containing Materials (ACM) and no Lead Based Paint (LBP).
Nicklaus Engineering, Inc. 3
3.0 PROJECT LIMITATIONS
The asbestos inspection was conducted in accordance with ASTM Standard E 2356-04, the Standard Practice for Comprehensive Building Asbestos Surveys. The intent of this standard is to provide procedures for conducting comprehensive surveys of buildings and facilities for the purpose of locating, identifying, quantifying, and assessing asbestos containing materials.
For this project, the following materials and/or areas were included in this survey:
• See Tables 1 and 2
Nicklaus Engineering, Inc. 4
4.0 INSPECTION PROCEDURES
4.1 Sample Inventory - Asbestos
Homogeneous areas of suspect materials to be disturbed were listed during the initial building inspection. A minimum of three (3) bulk samples of each material were collected for analysis. The samples are itemized in Table 1 below.
Table 1
Summary of Asbestos Samples Collected
Sample
ID
Description Location
Date
Sampled
1-3 White Roofing Admin Bldg 3/11/2024
4-6 Grey Roofing Desalting 3/11/2024
7-9 White Roofing Admin Trailer 3/11/2024
10-12 2x4 Acoustical ceiling tile Admin Trailer 3/11/2024
13-15 White Roofing Switch Yard Bldg 3/11/2024
16-18 2x4 Acoustical ceiling tile Switch Yard Bldg 3/11/2024
4.2 Sample Inventory – Lead-Based Paint
Painted surfaces to be disturbed were itemized during the initial building inspection. A minimum of three (3) readings of each roofing were collected. The readings are itemized in Table 2 below.
Table 2 Summary of Lead-Based Paint Samples Analyzed
Sample
ID
Description Location
Date
Sampled
899, 900, 901 White Roofing Admin Bldg 3/11/2024
902, 903, 904 Grey Roofing Desalting 3/11/2024
Nicklaus Engineering, Inc. 5
905, 906, 907 White Roofing Admin Trailer 3/11/2024
908, 909, 910 White Roofing Switch Yard Bldg 3/11/2024
Nicklaus Engineering, Inc. 6
4.3 Analysis
Asbestos samples were sent to Fiberquant Analytical Services for analysis by Polarized Light Microscopy (PLM) by EPA Method 600/R- 93/116. Sample layers which are friable and estimated by the analyst to contain ≤1% asbestos were point counted by the laboratory. Such point counting is required by NESHAP in order to rely on analytical results that are ≤1%.
Fiberquant Analytical Services is a certified laboratory recognized by the National Voluntary Laboratory Accreditation Program (NVLAP) administered by the United States Department of Commerce National Institute of Standards and Technology.
Lead based paint surfaces were analyzed in a non-destructive manner using an X-Ray Fluorescence (XRF) detector (Model Viken Detection PB200iXRF).
Nicklaus Engineering, Inc. 7
5.0 ANALYTICAL RESULTS
The sample results have been summarized in Tables 3 and 4 included as Attachment 1 for reference. There were no positive asbestos containing materials or lead based paint identified from this inspection however any materials that were not sufficiently proven to be non-ACM or non-LBP, shall be treated as ACM.
All suspect building materials must be analyzed to prove non-ACM. If any materials not listed in Table 1 are encountered, during demolition or renovation activities, work shall immediately cease and NEI shall be contacted to evaluate the material.
Similarly, all painted surfaces to be disturbed must be analyzed to determine the presence of LBP. If any materials not listed in Table 2 are encountered, during demolition or renovation activities, work shall immediately cease and NEI shall be contacted to evaluate the material.
Table 3 Asbestos Results
Sample
ID
Description Location Result Date Sampled
1-3 White Roofing Admin Bldg Negative 3/11/2024
4-6 Grey Roofing Desalting Negative 3/11/2024
7-9 White Roofing Admin Trailer Negative 3/11/2024
10-12 2x4 Acoustical Ceiling tile Admin Trailer Negative 3/11/2024
13-15 White Roofing Switch Yard Bldg Negative 3/11/2024
16-18 2x4 Acoustical Ceiling tile
Switch Yard Bldg Negative 3/11/2024
Nicklaus Engineering, Inc. 8
Table 4 Lead Based Paint Results
Sample
ID
Description Location Result
(mg/cm2 ) Date Sampled
899, 900, 901 White Roofing Admin Bldg Negative 3/11/2024
902, 903, 904 Grey Roofing Desalting Negative 3/11/2024
905, 906, 907 White Roofing Admin Trailer Negative 3/11/2024
908, 909, 910 White Roofing Switch Yard
Bldg Negative 3/11/2024
Nicklaus Engineering, Inc. 9
6.0 QUALITATIVE ASSESSMENT OF ACM
A qualitative assessment of the asbestos containing materials is necessary to make decisions regarding the treatment of asbestos containing materials. A qualitative assessment consists of an evaluation of the current condition as well as the potential for disturbance. No positive asbestos containing materials were discovered in this asbestos inspection.
Nicklaus Engineering, Inc. 10
7.0 QUALIFICATIONS
7.1 Inspector Qualifications
The inspectors involved in this asbestos inspection are certified as AHERA Asbestos Inspectors. Copies of the current asbestos certifications have been included as Attachment 2.
7.2 Laboratory Qualifications
The analytical laboratory is certified by the National Voluntary Laboratory Accreditation Program (NVLAP) of the National Institute of Standards and Technology (NIST) for the asbestos analyses conducted by the laboratory.
Nicklaus Engineering, Inc. 11
8.0 CONDITIONS AND LIMITATIONS
Nicklaus Engineering, Inc. has performed the tasks listed above requested by the Client in a thorough and professional manner consistent with commonly accepted standard industry practices, using state of the art practices and best available known technology, as of the date of the assessment.
The results reported and conclusions reached by Nicklaus Engineering, Inc. are solely for the benefit of the client. Nicklaus Engineering, Inc. assumes no obligation to advise the client of any changes in any real or potential asbestos or lead hazards at this residence that may or may not be later brought to our attention. Further conditions and limitations to this contracted report are included in the general terms and conditions supplied to the client with the contract for services.
Nicklaus Engineering, Inc. 12
9.0 LIST OF ATTACHMENTS
Attachment 1 Analytical Results
Attachment 2 Inspector Certifications
Attachment 1
Analytical Results
Client Job: PO Number:
JobNumber: 202402792
Routing Number: -
# Samples: 18
PLMn
PLM The "New" Method; see below
Client:
Polarized Light Microscope (PLM) Analysis for Asbestos in Bulk Sample
Method and Analysis Information:
Each bulk sample is first dissected under a 7-30x magnification stereo-microscope. This examination is used to determine the general type of sample, how many and what type of layers it has, and initial estimates of fiber types and quantities. Second, liquid media mounts are made of each layer -such mounts may be of selected fibers (used solely for identification purposes) or may be representative of the layer as a whole (used for quantitation purposes). The mounts may be made in a synthetic Canadian balsam, one of several solvents, or in refractive index oils (media of known refractive index). Generally, a variety of different mounts are made: some optimized for fiber visibility, some optimized for fiber identification, and some optimized for fiber quantitation. The mounted slides are then examined at 50-400x magnification on a Nikon Labphot-pol microscope. Optical characteristics are used to identify each observed fiber type; the optical data are contained for each sample on its detail analysis sheet, attached.
Current EPA and NESHAP regulations designate a result of ≤1 % asbestos as "negative" or "non-regulated"and >1 % asbestos as "positive" or "regulated." Samples containing layers that have been determined to be "positive" may have to be handled differently during a renovation or demolition than samples whose layers have been determined to be "negative." OSHA under CFR 1926.1101 regulates work done involving any detectable concentration of asbestos.
The method of fiber identification and quantitation is the “Standard Operating Procedures for the Analysis of Asbestos in Bulk Samples using Polarized Light Microscopy”, Chapter 7 of the Quality Assurance and Management Manual. This SOP and its associated reporting have been designed to satisfy all requirements in both EPA Method 600/M4-82-020 (The Interim Method) and EPA Method 600/R-93/116 (The New Method). The Interim Method is the required method for AHERA (US EPA 40 CFR Pt. 763), but this method calls for the reporting of composited results of multi-layered samples that is no longer an acceptable reporting practice in most circumstances. Current EPA rules, such as NESHAP (US EPA 40 CFR Pt. 61), as well as NVLAP accreditation policies, call for separate reporting for each layer of multi-layered samples. The New Method contains the same procedures for identification and quantification of asbestos as does the Interim Method, except that multi-layered samples are reported to comply with the latest US EPA rule. Fiberquant not only reports the asbestos content of each layer of multi-layered samples separately (satisfying current EPA and NVLAP reporting requirements), but Fiberquant also reports what percentage of the sample each layer comprises. Therefore, the results may be arithmetically composited to satisfy the reporting requirements of the Interim Method. The method of fiber quantitation is an estimation technique in which the analysts quantitation is routinely calibrated by reference quantitation standards, and which has been shown to be equivalent in precision and accuracy to point counting. Friability is estimated for the purposes of deciding when to point count. Friabilities determined in the field take precedence over those determined in the laboratory. Those sample layers which are friable and estimated by the analyst to contain <= 1% asbestos are point counted using 400 points. Such point counting is required by NESHAP (National Emission Standards for Hazardous Air Polutants, Nov. 1990) in order to rely on analytical results that are ≤ 1%. The coefficient of variation for the estimation quantitation technique is 100% in the range 0-5%.
This means that PLM analysis is not capable of conclusively determining whether a layer containing close to 1% asbestos is actually "positive" or "negative". For this reason, Fiberquant refers to results where asbestos was detected but ≤ 1% as "borderline negative", and results where asbestos was >1 % but <= 2% as "borderline positive" to indicate the uncertainty in assigning a "positive" or "negative" label. In the sample summary, "ND" means that no asbestos was detected during the analysis. A "Tr" or "Trace" of asbestos reported is defined for our purposes as the detection of several asbestos fibers during the analysis; this level would be right at the limit of detection for the method. Trace is only reported on the analysis detail - in the summary a trace would be reported as <=1%. The limit of detection (the smallest % of asbestos that can be detected) varies greatly depending on the matrix in which the asbestos is found. As little as 0.001% asbestos can be detected in favorable samples, while detection in unfavorable samples may approach the detection limit of 1% stated in the method. During the analysis, the analyst, for Fiberquant identification purposes only, determines the "apparent sample type" and "apparent layer types." It must be emphasized that these types are only what is apparent. Often, different materials appear similar or identical after sampling, so the analyst may assign a type other than what was sampled.
Floor tiles present a special problem for PLM asbestos analysis. Floor tile can contain chrysotile fibers so thin that they cannot be resolved by optical methods. In such a case, we may observe a percentage of asbestos which is lower than the actual percentage, or not observe asbestos at all when some is present. For this reason, floor tiles reported as negative should be confirmed to be negative using transmission electron microscope (TEM) analysis. Likewise, vermiculite insulation materials containing traces of asbestiform asbestos present a problem for routine PLM analysis - the amphiboles are sometimes present in trace amounts inhomogeneously distributed. For this reason, loose vermiculite samples reported as negative should be confirmed to contain no amphibole using hydroseparation techniques.
The samples were analyzed under the following ongoing quality assurance program: Blank samples are routinely analyzed to maintain contamination-free materials. Each analyst has at least a bachelor's degree in physical science, and has also completed extensive training specific to asbestos analysis for 1-3 months before being allowed to analyze client samples. Qualitative reference samples are routinely analyzed to assure that analysts
Method: EPA 600/R-93/116Rec: 3/13/2024
Report Date: 3/14/2024 Date Analyzed: 3/13/2024
Fiberquant Internal SOP:
NEI ENVIRONMENTAL
1851 W 24TH ST STE 101
YUMA, AZ
Office Phone: (928) 344-8374
FAX: (928) 726-6994
85364-0000
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 1 of 11
PLM Analysis Summary: Job Number: 202402792 can identify asbestos and asbestos-look-alike fibers. Quantitative reference samples are routinely analyzed to calibrate and characterize the estimation procedure. Microscope alignment is checked each day. Refractive index oils are calibrated at least quarterly. At least 10% of client samples are re-analyzed from scratch by a different analyst than the original, and any discrepancies are resolved for the sample and similar sample types before the results are reported. All quality checks performed for these samples were in control except as detailed in the "Analytical Notes" below. All analysts participate in interlab round robins and proficiency testing to assure competence. Fiberquant is accredited by NVLAP (Lab code #101031) for the analysis of bulk samples for asbestos using PLM. Accreditation does not imply endorsement by the EPA, any other United States governmental agency or any private agency or association. Each lab analysis refers only to the sample tested, and may not, due to the sampling process, be representative of the material sampled. This report may not be reproduced except in full, without the approval of Fiberquant Analytical Services.
Job Analysis Notes:
Some results may have been calculated using client supplied data, such as volume or area sampled, for which Fiberquant assumes no liability for accuracy.
Sample Number Lab Number Apparent Sample Type * Asbestos Detected Yes or No
Layer Color Apparent Layer Type * Asbestos Results
Roofing2024-02792- 11A Asbestos Detected? NoSample # no asbestos detectedmembranewhiteLayer # 1
Roofing2024-02792- 21B Asbestos Detected? NoSample # no asbestos detectedmembranewhiteLayer # 1
Roofing2024-02792- 31C Asbestos Detected? NoSample # no asbestos detectedmembranewhiteLayer # 1
Roofing2024-02792- 42A Asbestos Detected? NoSample # no asbestos detectedfoamblueLayer # 1 no asbestos detectedinsulationgrayLayer # 2
Roofing2024-02792- 52B Asbestos Detected? NoSample # no asbestos detectedfoamblueLayer # 1 no asbestos detectedfabricblackLayer # 2
Roofing2024-02792- 62C Asbestos Detected? NoSample # no asbestos detectedfoamblueLayer # 1 no asbestos detectedfabricblackLayer # 2
Roofing2024-02792- 73A Asbestos Detected? NoSample # no asbestos detectedmembranewhiteLayer # 1 no asbestos detectedfabricwhiteLayer # 2 no asbestos detectedfabricwhiteLayer # 3 no asbestos detectedmembraneblackLayer # 4 no asbestos detectedmembraneblackLayer # 5
Roofing2024-02792- 83B Asbestos Detected? NoSample # no asbestos detectedmembranewhiteLayer # 1 no asbestos detectedfabricwhiteLayer # 2 no asbestos detectedmembraneblackLayer # 3 no asbestos detectedmembraneblackLayer # 4 no asbestos detectedmembraneblackLayer # 5 no asbestos detectedmembraneblackLayer # 6
Roofing2024-02792- 93C Asbestos Detected? NoSample # no asbestos detectedmembranewhiteLayer # 1 no asbestos detectedmembraneblackLayer # 2 no asbestos detectedmembraneblackLayer # 3 no asbestos detectedmembraneblackLayer # 4 no asbestos detectedmembraneblackLayer # 5 no asbestos detectedmasticclearLayer # 6
Acoustical Tile2024-02792- 104A Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tilegrayLayer # 2
Acoustical Tile2024-02792- 114B Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tilegrayLayer # 2
Acoustical Tile2024-02792- 124C Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tilegrayLayer # 2
Roofing2024-02792- 135A Asbestos Detected? NoSample # no asbestos detectedcoatingclearLayer # 1 no asbestos detectedfoamorangeLayer # 2
Roofing2024-02792- 145B Asbestos Detected? NoSample # no asbestos detectedcoatingwhiteLayer # 1 no asbestos detectedfoamorangeLayer # 2
Roofing2024-02792- 155C Asbestos Detected? NoSample # no asbestos detectedcoatingwhiteLayer # 1 no asbestos detectedfoamorangeLayer # 2
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 2 of 11
Acoustical Tile2024-02792- 166A Asbestos Detected? NoSample # no asbestos detectedpaintwhiteLayer # 1 no asbestos detectedacoustical tilegrayLayer # 2
Acoustical Tile2024-02792- 176B Asbestos Detected? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedacoustical tileoff-whiteLayer # 2
Acoustical Tile2024-02792- 186C Asbestos Detected? NoSample # no asbestos detectedpaintoff-whiteLayer # 1 no asbestos detectedacoustical tileoff-whiteLayer # 2
* Apparent Sample Types and Apparent Layer Types are as they appeared to the analyst. Since many types of materials appear similar after sampling damage, the apparent type of material may not be the actual type of material.
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 3 of 11
PLM Analysis Details Job Number: 202402792
2024-02792- 11A 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
Yes RubberyOKAn?
1# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): rubber, filler, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 100 2-5% - - - - -membrane white 1
100Total % 2-5% - - - - -Overall %
2024-02792- 21B 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024 Homogeneous
Roofing Yes
RubberyOKAn?
1# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): rubber, filler, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 100 2-5% - - - - -membrane white 1
100Total % 2-5% - - - - -Overall %
2024-02792- 31C 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
Yes RubberyOKAn?
1# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): rubber, filler, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 100 2-5% - - - - -membrane white 1
100Total % 2-5% - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 4 of 11
2024-02792- 42A 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No RubberyOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): polymer foam, powder, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 55 n.d. - - - - -foam blue 2 2 45 80-90% - - - - -insulation gray 3
100Total % 40-50% - - - - -Overall %
2024-02792- 52B 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No RubberyOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): polymer foam, powder, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 20 n.d. - - - - -foam blue 2 2 80 80-90% - - - - -fabric black 1
100Total % 60-70% - - - - -Overall %
2024-02792- 62C 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No RubberyOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): polymer foam, powder, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 50 n.d. - - - - -foam blue 2 2 50 80-90% - - - - -fabric black 1
100Total % 40-50% - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 5 of 11
2024-02792- 73A 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No Fibrous SolidOKAn?
5# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): rubber, polymer, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 20 50-60% - - - - -membrane white 1 2 20 70-80% - - - - -fabric white 1 3 10 70-80% - - - - -fabric white 1 4 25 n.d. - - - - -membrane black 1 5 25 n.d. - - - - -membrane black 1
100Total % 30-40% - - - - -Overall %
2024-02792- 83B 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No Fibrous SolidOKAn?
6# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): rubber, polymer, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 25 20-30% - - - - -membrane white 1 2 15 70-80% - - - - -fabric white 1 3 15 n.d. - - - - -membrane black 1 4 15 n.d. - - - - -membrane black 1 5 15 n.d. - - - - -membrane black 1 6 15 n.d. - - - - -membrane black 1
100Total % 10-20% - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 6 of 11
2024-02792- 93C 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No Fibrous SolidOKAn?
6# Layers NoAsbestos Detected?
Apparent Smp Type synthetic fiber (extrFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations synthetic fiber (extruded) W E N N H + P
Non-Fibrous Components (in approx. decreasing order): rubber, polymer, Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 23 10-20% - - - - -membrane white 1 2 19 n.d. - - - - -membrane black 1 3 19 n.d. - - - - -membrane black 1 4 19 n.d. - - - - -membrane black 1 5 19 n.d. - - - - -membrane black 1 6 1 n.d. - - - - -mastic clear 1
100Total % 2-5% - - - - -Overall %
2024-02792- 104A 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 1 n.d. n.d. - - - -paint white 1 2 99 20-30% 2-5% - - - -acoustical tile gray 3
100Total % 20-30% 2-5% - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 7 of 11
2024-02792- 114B 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 1 n.d. n.d. - - - -paint white 1 2 99 20-30% 2-5% - - - -acoustical tile gray 3
100Total % 20-30% 2-5% - - - -Overall %
2024-02792- 124C 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 1 n.d. n.d. - - - -paint white 1 2 99 20-30% 2-5% - - - -acoustical tile gray 3
100Total % 20-30% 2-5% - - - -Overall %
2024-02792- 135A 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No RubberyOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type noneFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations none
Non-Fibrous Components (in approx. decreasing order): polymer foam, polymer, rock
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 30 n.d. - - - - -coating clear 1 2 70 n.d. - - - - -foam orange 3
100Total % n.d. - - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 8 of 11
2024-02792- 145B 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No RubberyOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type noneFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations none
Non-Fibrous Components (in approx. decreasing order): polymer foam, polymer, rock
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 10 n.d. - - - - -coating white 1 2 90 n.d. - - - - -foam orange 3
100Total % n.d. - - - - -Overall %
2024-02792- 155C 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Roofing
No RubberyOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type noneFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of matrix using solvent.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations none
Non-Fibrous Components (in approx. decreasing order): polymer foam, polymer, rock
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 15 n.d. - - - - -coating white 1 2 85 n.d. - - - - -foam orange 3
100Total % n.d. - - - - -Overall %
2024-02792- 166A 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type cellulose fiber glass fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations cellulose fiber glass fiber
W F N N H + U
CL D Y
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 1 n.d. n.d. - - - -paint white 1 2 99 20-30% <=1% - - - -acoustical tile gray 3
100Total % 20-30% <=1% - - - -Overall %
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 9 of 11
2024-02792- 176B 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type glass fiber cellulose fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations glass fiber cellulose fiber
CL D Y
W F N N H + U
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. n.d. - - - -paint off-white 1 2 98 30-40% 2-5% - - - -acoustical tile off-white 3
100Total % 30-40% 2-5% - - - -Overall %
2024-02792- 186C 3/11/2024Lab Number Sample Sampled:
DMSAnalyzed By 3/14/2024
Homogeneous Acoustical Tile
No Fibrous MatOKAn?
2# Layers NoAsbestos Detected?
Apparent Smp Type glass fiber cellulose fiberFiber Identification:
Sample Analytical Note
Procedure: tweased apart using forceps. Procedure: dissolution of paint matrix using solvent. Procedure: dissolution of acoustical tile using acid.
Fibers
Color Mrph Iso Pleo Bi Elg Ext Oil Col Par Col Per RI Par RI Per
Refractive Index Determinations glass fiber cellulose fiber
CL D Y
W F N N H + U
Non-Fibrous Components (in approx. decreasing order): perlite, powder, binder
Condition: acceptable
Layers
# Layer Type % Color Friability
Calibrated Visual Estimate of Percents of Each Fiber
Fib 1 Fib 2 Fib 3 Fib 4 Fib 5 Fib 6
1 2 n.d. n.d. - - - -paint off-white 1 2 98 30-40% 2-5% - - - -acoustical tile off-white 3
100Total % 30-40% 2-5% - - - -Overall %
Fr=Friability: 1=very non-friable; 2= non-friable; 3=friable; 4=highly friable Colors: B=black;BL=blue;BR=brown;CL=clear;G=Green;GY=gray;OR=orange;OW=off-white;PN=pink;PU=purple;R=red;TN=tan;W=white;Y=yellow;V=various Fiber Morphology: A=fine fibers/bundles, white, sinewy, flexible; B=fine fibers/bundles, w-br, straight, broomed ends; C=fine fibers/bundles, blue, straight, broomed ends;
D=fine to coarse fibers, CL-B, brittle; E=coarse fibers,CL or dyed, striated; F=coarse fibers or splinters, W-BR, ribbon-like; G=lath-like or shards, low aspect ratio, may taper Iso=isotropism - may be yes or no; Pleo=pleochroism - may be yes or no; Bi=birefringence - may be None, Low, Medium or High Elg=sign of elongation - may be +, - or B (both); Ext=extinction - may be Parallel, Oblique, None or Undulating; Oil=medium used to for dispersion staining Col Par=dispersion staining colors parallel to the fiber (fiber/halo): b/w=black/white; dg/py=dark gray/pale yellow; vg/y=violet gray/yellow; db/ly=dark blue/lemon yellow; vb/g= vivid blue/gold; sb/o=sky blue/orange; pb/r=pale blue/red; gb/dr=gray blue/dark red; w/b=white/black. Col Perp=same only perpendicular to fiber.
RI Par=refractive index parallel to fiber; RI Perp=refractive index perpendicular to fiber
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 10 of 11
14-Mar-24Analyst: DAVID M. SCHALLER
Larry S. Pierce, Approved Accreditation Signatory
Printed:
14-Mar-24Original Print Date:
5025 S. 33rd Street Phoenix, Arizona 85040-2816 Phone: 602-276-6139 1-800-743-2687 FAX: 602-276-4558
Fiberquant, Inc. Page 11 of 11
Attachment 2
Inspector Certification
| Table of Contents |
| 1.0 ACRONYMS AND ABBREVIATIONS |
| 2.0 EXECUTIVE SUMMARY |
| 3.0 PROJECT LIMITATIONS |
| 4.0 INSPECTION PROCEDURES |
| 4.1 Sample Inventory - Asbestos |
| 4.2 Sample Inventory – Lead-Based Paint |
| Painted surfaces to be disturbed were itemized during the initial building inspection. A minimum of three (3) readings of each roofing were collected. The readings are itemized in Table 2 below. |
| 4.3 Analysis |
| 5.0 ANALYTICAL RESULTS |
| 6.0 QUALITATIVE ASSESSMENT OF ACM |
| 7.0 QUALIFICATIONS |
| 7.1 Inspector Qualifications |
| 7.2 Laboratory Qualifications |
| 8.0 Conditions and Limitations |
| 9.0 LIST OF ATTACHMENTS |