Attachment 10e.3 – E092 thru E101 Wkstn Display-FMECA.xlsx

XLSX spreadsheet 45 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains a Failure Modes and Effects Criticality Analysis (FMECA) worksheet for displays used on an Integrated Battle Command System (IBCS). The FMECA identifies potential failure modes for the displays, their likely causes and effects. It analyzes 40 total failure modes across 10 displays. The most common failure modes are failure to operate at a prescribed time, non-normal operation, premature operation, and shorted input power. The document assigns each failure mode a severity classification of Category III and estimates their probability of occurrence. It also describes compensating provisions like display redundancies that reduce severity classifications.

The related federal contract opportunity is a draft Request for Proposal for IBCS low-rate initial production and full-rate production. It involves producing IBCS hardware components in accordance with technical data packages and specifications, including maintaining approved software and firmware updates. Engineering changes may be required for obsolescence, new capabilities or export. The RFP has not been officially released and the government is not currently seeking proposals. The solicitation number is W31P4Q-20-R-0015 and it originates from the Department of the Army Contracting Command.

View the file

Other files for this federal contract opportunity

Other files attached to DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
Attachment 10d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 15a- Example Skill Classification Crosswalk.xlsx XLSX spreadsheet
Attachment 16 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 10a.11 – R029 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 10c.2 – E044 Firewall Black-FMECA.xlsx XLSX spreadsheet
Attachment 13d - IBCS-A301-003 Vol III Program of Instruction.pdf PDF
Attachment 10g - IBCS - 243-003 HW FMECA Results.pdf PDF
Attachment 10d.9 – E156 UPS-FMECA.xlsx XLSX spreadsheet
Attachment 10d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10b.10 – E034 R112 Shelter – Server Stack – 04-FMECA.xlsx XLSX spreadsheet
Attachment 10e.1 – E067 – EtherNet Switch-FMECA.xlsx XLSX spreadsheet
Attachment 10d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 10c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 10b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 22a.3 - S280_SystemPowerAnalysis_Draft_12-5-2017.xlsx XLSX spreadsheet
Attachment 10c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 10b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 13a -A293-004 ETM 60 Percent Draft.pdf PDF
Attachment 10d.10 – E157 KVM Switch 2 Shelter-FMECA.xlsx XLSX spreadsheet
Attachment 10c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 14 - Technical Library.docx DOCX document
Attachment 10e.2 – E082 thru E091 Wkstn Laptop-FMECA.xlsx XLSX spreadsheet
Attachment 10c.14 – E064 Shelter Router Black – FMECA.xlsx XLSX spreadsheet
Attachment 10c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.i - PL-ALH-213030 00 CABLE ASSEMBLY, CASS J1 AND J3.pdf PDF
Attachment 10a.8 – R008 Media Converter Chassis-FMECA.xlsx XLSX spreadsheet
Attachment 10e.6 – E143 – ICE UPS-FMECA.xlsx XLSX spreadsheet
Attachment 07 - AIAMD Requirements Prioritization 1-n table.docx DOCX document
Attachment 10a.2 – R002 BPU-FMECAAttachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 06 - Obsolete Parts List.pdf PDF
Attachment 04a - Draft_EOC Acceptance Test Procedures.docx DOCX document
Attachment 22a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 15b - Fixed Price Level of Effort Labor Categories.xlsx XLSX spreadsheet
Attachment 10h - SWFMEA RESULTS.xlsx XLSX spreadsheet
Attachment 22a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf PDF
Attachment 04c - ECT_Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 22a.1.a - ALH-208670 05 IBCS SHELTER INTERCONNECT.pdf PDF
Attachment 10a.4 – R004 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 13 - Training Documentation.docx DOCX document
Attachment 10a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.j - PL-ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 10c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 10a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 19 - Section L - Instructions - Conditions - And Notices To Offerors.docx DOCX document
Attachment 10c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 10e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Show all 50

DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

Row LabelsSum of CmCount of Failure Mode Description
Failure to operate at a prescribed time9.11E-0510
Non-normal operation9.11E-0510
Premature operation9.11E-0510
Shorted Input Power9.11E-0510
Grand Total3.64E-0440

Prelim Analysis

Major End Item:ICBS Colaborative Environment (ICE)
PRELIMINARY ANALYSIS:Parent LRU:E092 thru E101-ICE Workstation Display #1 thru #10
Component:TL-351 20.1" RUGGED DISPLAY
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =3.64E-04
Failure ModesCount of
Failure ModesSeverity ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Failure to operate at a prescribed time1025.00%Category III40Failure to operate at a prescribed time9.11E-0510
Non-normal operation1025.00%Failure to operate at a prescribed time10Non-normal operation9.11E-0510
Premature operation1025.00%Non-normal operation10Premature operation9.11E-0510
Shorted Input Power1025.00%Premature operation10Shorted Input Power9.11E-0510
Grand Total40Shorted Input Power10Grand Total3.64E-0440
Grand Total40

Cat I and Cat II No Category I and Category II Classifications

Data

Major End Item:ICBS Colaborative Environment (ICE)
Parent LRU:E092 thru E101-ICE Workstation Display #1 thru #10
Component:TL-351 20.1" RUGGED DISPLAY
Mission Phase-Operational Mode:All Phases
FPMH:10.124(20.247)
t:72hr72
Cr = ∑Cm =3.64E-05
Modified Cr =3.64E-05
Due to the k-of-10 Configuration of the ICE (k = 4) a Failure Rate Adjustmust of 50% was performed.
No Category I and Category II Classifications due to the k-of-n configuration of the ICE
Failure Effect atFailure Detection MethodCompensating Provisions
ID#Parent LRUFunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeveverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
3216E092-ICE Display #1Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-31 (ICE Workstation #1 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3217E092-ICE Display #1Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3218E092-ICE Display #1Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-41 (ICE Display #1 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3219E092-ICE Display #1Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-51 (ICE Display #1 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3220E093-ICE Display #2Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-32 (ICE Workstation #2 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3221E093-ICE Display #2Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3222E093-ICE Display #2Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-42 (ICE Display #2 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3223E093-ICE Display #2Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-52 (ICE Display #2 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3224E094-ICE Display #3Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-33 (ICE Workstation #3 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3225E094-ICE Display #3Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3226E094-ICE Display #3Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-43 (ICE Display #3 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3227E094-ICE Display #3Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-53 (ICE Display #3 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3228E095-ICE Display #4Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-34 (ICE Workstation #4 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3229E095-ICE Display #4Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3230E095-ICE Display #4Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-44 (ICE Display #4 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3231E095-ICE Display #4Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-54 (ICE Display #4 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3232E096-ICE Display #5Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-35 (ICE Workstation #5 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3233E096-ICE Display #5Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3234E096-ICE Display #5Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-45 (ICE Display #5 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3235E096-ICE Display #5Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-55 (ICE Display #5 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3236E097-ICE Display #6Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-36 (ICE Workstation #6 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3237E097-ICE Display #6Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3238E097-ICE Display #6Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-46 (ICE Display #6 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3239E097-ICE Display #6Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-56 (ICE Display #6 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3240E098-ICE Display #7Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-37 (ICE Workstation #7 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3241E098-ICE Display #7Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3242E098-ICE Display #7Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-47 (ICE Display #7 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3243E098-ICE Display #7Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-57 (ICE Display #7 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3244E099-ICE Display #8Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-38 (ICE Workstation #8 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3245E099-ICE Display #8Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3246E099-ICE Display #8Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-48 (ICE Display #8 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3247E099-ICE Display #8Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-58 (ICE Display #8 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3248E100-ICE Display #9Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-39 (ICE Workstation #9 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3249E100-ICE Display #9Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3250E100-ICE Display #9Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-49 (ICE Display #9 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3251E100-ICE Display #9Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-59 (ICE Display #9 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3252E101-ICE Display #10Workstation DisplayFailure to operate at a prescribed timeHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-40 (ICE Workstation #10 Power Indicator is OFF)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3253E101-ICE Display #10Workstation DisplayShorted Input PowerHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20N/ATBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3254E101-ICE Display #10Workstation DisplayNon-normal operationHardware FailureComponent InoperativeLoss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-50 (ICE Display #10 Relocation Test)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06
3255E101-ICE Display #10Workstation DisplayPremature operationHardware FailureInadvertent operationPossible loss of 1 or 2 workstation displaysPossible degraded mission.N/AN/AOB-450-20VI-450-60 (ICE Display #10 Image Problem or Fault Light Indication)TBDCategory IIIEOSs are RedundantCategory III0.050.052.50E-011.01E-059.11E-069.11E-06