Attachment 22a.1.c - ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf

PDF 220 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP
Solicitation number
W31P4Q-20-R-0015
Issued by

About this file

This document contains technical drawings and specifications for a cable assembly to be used in an Integrated Battle Command System. The cable assembly, designated ALH-211130 00 CABLE ASSEMBLY CASS DC POWER, is a 28V DC power cable that connects various system components. The document provides details on materials, tolerances, testing requirements, markings, and other specifications to ensure form, fit and function of the cable assembly.

The related federal contract opportunity is a draft RFP from the Department of the Army seeking proposals for Low Rate Initial Production and Full Rate Production of Integrated Battle Command System hardware end items. Respondents would be required to produce hardware in accordance with supplied technical data packages and specifications, and engineering changes may be required for obsolescence, new capabilities or export considerations. The RFP is currently a draft for comment only and the government is not accepting proposals in response to the posted information.

View the file

Other files

File Type Posted
Attachment 10h - SWFMEA RESULTS.xlsx XLSX spreadsheet
Attachment 10a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.a - ALH-208670 05 IBCS SHELTER INTERCONNECT.pdf PDF
Attachment 22a - CASS to PDRS.docx DOCX document
Attachment 10c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 10a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 20 - Section M - Evaluation Factors For Award.docx DOCX document
Attachment 10a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 10c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 10a.2 – R002 BPU-FMECAAttachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10g - IBCS - 243-003 HW FMECA Results.pdf PDF
Attachment 22a.3 - S280_SystemPowerAnalysis_Draft_12-5-2017.xlsx XLSX spreadsheet
Attachment 10c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 10c.14 – E064 Shelter Router Black – FMECA.xlsx XLSX spreadsheet
Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA.xlsx XLSX spreadsheet
Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 10c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 10e.2 – E082 thru E091 Wkstn Laptop-FMECA.xlsx XLSX spreadsheet
Attachment 10d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 13c - IBCS-A301-003 Vol II Instructor Guide.pdf PDF
Attachment 03 - GFP Attachment - LRIP_FRP - 20 April 2020.xlsx XLSX spreadsheet
Attachment 10a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 22a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 19 - Section L - Instructions - Conditions - And Notices To Offerors.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.e - ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 04b - Draft_Relay Acceptance Test Procedures.docx DOCX document
Attachment 22a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 10c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 10b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 16 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 13a -A293-004 ETM 60 Percent Draft.pdf PDF
Attachment 04a - Draft_EOC Acceptance Test Procedures.docx DOCX document
Attachment 10d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10e.1 – E067 – EtherNet Switch-FMECA.xlsx XLSX spreadsheet
Attachment 06 - Obsolete Parts List.pdf PDF
Attachment 04c - ECT_Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 15a- Example Skill Classification Crosswalk.xlsx XLSX spreadsheet
Attachment 10c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 10a.8 – R008 Media Converter Chassis-FMECA.xlsx XLSX spreadsheet
Attachment 10b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.b - ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 10c.1 – E043 Firewall Red-FMECA.xlsx XLSX spreadsheet
Show 40 more

Latest 50 of 98 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

2012/08/06

W31P4Q-08-C-0148

DATEAPPROVALS

PROJECT APPROVAL

DESIGN ACTIVITY

CCB CHAIR

T. ALKIRE

J. WETHINGTON

ENGR

K. HANVEY

J. BULLEIGH

CONTRACT NO.

1 OF 3 SHEETNONE SCALE

NG-IPS-ALH8-AC-D00 (IBCS)

CAGE CODESIZE DWG NO. REV.

WARNING - This document contains technical data whose export

Official version of this document is electronically controlled in an online PLM system. Verify version level prior to use.

NOTES:

1. APPLICABLE STANDARDS/SPECIFICATIONS:

ASME Y14.5M - 1994, DIMENSIONING AND TOLERANCING

2. WORKMANSHIP SHALL MEET OR EXCEED IPC/WHMA-A-620 CLASS 3.

3. SEE ALH-900000 FOR ENGINEERING APPROVED EQUIVALENTS FOR

NON-DEVELOPMENTAL OFF THE SHELF PARTS.

4 BAND MARKINGS:

4.1 BAND MARKINGS SHALL BE SINGLE THERMAL MARKING EMPLOYING

A PERMANENT BLACK MATERIAL. CHARACTERS SHALL BE

VERTICAL GOTHIC TYPE. HEIGHT SHALL BE PROPORTIONAL AND

LEGIBLE.

4.2 BAND SHALL EXTEND PROPORTIONALLY BEYOND LETTERING ON

FRONT AND REAR OF MARKINGS.

5 ENTER MANUFACTURER'S CAGE CODE IN PLACE OF "_ _ _ _ _" IAW

MIL-STD-130.

6 CABLE LENGTHS DETERMINED BY 4-DIGIT DASH NUMBER (i.e.

ALH-123456-0120 IS 120 INCHES).

CABLE TOLERANCE: THE LENGTH OF A CABLE SHALL BE MEASURED

FROM ONE END OF THE CABLE ASSEMBLY TO THE OTHER END

(REFERENCE CABLE ASSEMBLY DIAGRAM). CABLE LENGTH TOLERANCE

SHALL BE AS SHOWN IN THE CABLE LENGTH TOLERANCE TABLE

UNLESS OTHERWISE DEFINED ON THE DRAWING/DOCUMENTATION.

7. CABLES SHALL BE TESTED BY REQUIREMENT TS-1C IDENTIFIED IN

ALH-102546.

8 BAND MARKING ORIENTATION: FOR CABLES LESS THAN OR EQUAL TO

18 INCHES, ONLY ONE CENTER BAND MARKING LABEL "A" IS REQUIRED

ON THE CABLE CENTERED ±.5 INCHES ON THE EXPOSED CABLE

BETWEEN CONNECTORS OR TERMINALS. MARKING LABELS "B" AND "C"

ARE TO BE LOCATED 1" ±.5" FROM BACKSHELL/TERMINAL IN PLACE OF

DIMENSION SHOWN.

9 REPLACE: MM-YYYY WITH MONTH AND YEAR OF MANUFACTURE;

XX WITH DRAWING REVISION USED FOR MANUFACTURE.

10. CABLE PREPARATION, CRIMP TOOL/DIE, AND CONNECTOR/WIRE

ASSEMBLY SHALL BE AS SPECIFIED IN THE INDIVIDUAL CONNECTOR

SPECIFICATIONS OR AS REQUIRED TO MEET THE OVERALL CABLE

ASSEMBLY REQUIREMENTS.

11 FOR ADEQUATE STRAIN RELIEF, THIS AREA MAY REQUIRE ONE OR

MORE LAYER(S) OF FN 2.

WARNING - This document contains technical data whose export

Copyright 2012 Northrop Grumman Systems Corporation

DISTRIBUTION STATEMENT C: Distribution authorized to the U.S. Government Agencies and their contractors; Administrative and Operational Use; 05 Jan 2007. Other requests for this document shall be referred to ATTN: SFAE-MSLS-IAMD, Program Executive Office Missiles and Space, Integrated Air and Missile Defense Project Office. Bldg. 5250 Martin Road, Huntsville, Al 35898-8000.

is restricted by the Arms Export Control Act (Title 22, U.S.C., Sec 2751, et. seq.) or the Export Administration Act of 1979, as amended, Title 50, U.S.C., App. 2401 et. seq. Violations of these export laws are subject to severe criminal penalties. Disseminate in accordance with provisions of DoD Directive 5230.25.

2012/08/06

REV.DWG NO.SIZE CAGE CODE

NGMS-ALH8-AC-D04

SCALE NONE SHEET 2 OF 3

Official version of this document is electronically controlled in an online PLM system. Verify version level prior to use.

VIEW A-A

KEYWAY

A D C

B

A A

CABLE ASSEMBLY

A

TABLE

MARKING DESCRIPTION

318U8 ASSY ALH-211130-XXXX

MM-YYYY REV XX MFR _ _ _ _ _

CASS DC POWER CABLE

A

28 V DC

PWR SOURCE

B

SEE TABLE

FOR MARKINGS4X

C

AB

28 V DC

J4

C

2X 2.0±.52X 1.0±.5

2 2X

LENGTH SHALL BE AS REQUIRED

FOR CABLE ASSEMBLY

REV.DWG NO.SIZE CAGE CODE

NGMS-ALH8-AC-D04

SCALE NONE SHEET 3 OF 3

Official version of this document is electronically controlled in an online PLM system. Verify version level prior to use.

WIRING DIAGRAM

REF

REF

5C

A

B

D

RED (+28 VDC)

BLACK (-28 VDC RTN)

B

C

A

D

WHITE

TRIM CONDUCTOR

FLUSH WITH END

OF CABLE

2X

File details come from the government source that posted it. Updated .