Attachment 10c.16 – E069 Media Converter 03 - FMECA.xlsx
XLSX spreadsheet 35 KB Posted
- Attached to
- DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
- Solicitation number
- W31P4Q-20-R-0015
About this file
This document contains two parts: an attachment analyzing the failure modes and effects of a media converter component through a Failure Modes, Effects and Criticality Analysis (FMECA), and a draft Request for Proposal (RFP) for the Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production (LRIP/FRP) hardware segment.
The FMECA attachment analyzes four potential failure modes for a media converter component used in an E069 shelter: does not operate, intermittent operation, degraded functional operation, and no failures. It assigns severity classifications and calculates failure rates both with and without considering redundant emergency operation centers (EOCs).
The draft RFP seeks hardware production for IBCS, including maintaining approved software/firmware updates and authority to operate on existing hardware. Engineering changes may be required for obsolescence, new capabilities, and export considerations. The RFP is from the Department of the Army Materiel Command Contracting Command at Redstone Arsenal for an unspecified dollar value and period of performance. No response is currently being solicited as this is a draft for comment only.
View the file
Other files for this federal contract opportunity
Show all 50
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pivot Table
| Row Labels | Sum of Cm | Count of Failure Mode Description |
| Does not operate | 1.48E-05 | 2 |
| Intermittent | 6.72E-06 | 1 |
| Degraded (Functional) | 0.00E+00 | 1 |
| Grand Total | 2.15E-05 | 4 |
Prelim Analysis
| PRELIMINARY ANALYSIS: | Major End Item: | Shelter | |||
| Parent LRU: | E069-Media Converter-03 ICE) | ||||
| Component: | MEDIA CONVERTOR, WIN-T A334 | ||||
| Mission Phase-Operational Mode: | All Phases | ||||
| Cr = ∑Cm = | 2.15E-05 | ||||
| Failure Modes | Count of | ||||
| Failure Modes | Severity | ||||
| Classifications | Count of |
Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes
| Does not operate | 2 | 50.0% | Category II | 2 | Does not operate | 1.48E-05 | 2 |
| Degraded (Functional) | 1 | 25.0% | Does not operate | 1 | Intermittent | 6.72E-06 | 1 |
| Intermittent | 1 | 25.0% | Intermittent | 1 | Degraded (Functional) | 0.00E+00 | 1 |
| Grand Total | 4 | Category III | 1 | Grand Total | 2.15E-05 | 4 | |
| Does not operate | 1 | ||||||
| Category IV | 1 | ||||||
| Degraded (Functional) | 1 | ||||||
| Grand Total | 4 |
Cat I and II
| Major End Item: | Shelter | ||||||||||||||||||||
| Parent LRU: | E069-Media Converter-03 (ICE) | ||||||||||||||||||||
| Component: | MEDIA CONVERTOR, WIN-T A334 | ||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||||||
| FPMH: | 9.5583 | ||||||||||||||||||||
| t: | 72 | ||||||||||||||||||||
| Cr = ∑Cm = | 2.75E-04 | ||||||||||||||||||||
| Modified Cr = | 4.30E-05 | ||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R | |||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compensating Provisions | |||||||||||||||||||
| ID# | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | ||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | ||||||||||||||||||
| Capabilities | Severity | ||||||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||||||
| Modifications | Modified Severity | ||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | |||||||||||||||
| 2204 | CONVERTS FIBER TO COPPER - FOR WIN-T RED DATA | Does not operate | Hardware failure or software defect | Loss of function | Loss of WIN-T Red Data | Degraded Mission due to loss of External Sensor Data | N/A | N/A | N/A | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.5000 | 9.56E-06 | 1.72E-04 | 1.72E-05 | |
| 2205 | CONVERTS FIBER TO COPPER - FOR WIN-T RED DATA | Intermittent | Hardware failure or software defect | Intermittent continuity | Probable Loss of WIN-T Red Data | Probable Degraded Mission due to loss of External Sensor Data | N/A | N/A | N/A | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.2500 | 9.56E-06 | 8.60E-05 | 8.60E-06 |
E069 Data
| Major End Item: | Shelter | ||||||||||||||||||||
| Parent LRU: | E069-Media Converter-03 (ICE) | ||||||||||||||||||||
| Component: | MEDIA CONVERTOR, WIN-T A334 | ||||||||||||||||||||
| Mission Phase-Operational Mode: | All Phases | ||||||||||||||||||||
| FPMH: | 0.7463 | ||||||||||||||||||||
| t: | 72 | ||||||||||||||||||||
| Cr = ∑Cm = | 2.15E-05 | ||||||||||||||||||||
| Modified Cr = | 3.36E-06 | ||||||||||||||||||||
| Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R | |||||||||||||||||||||
| Failure Effect at | Failure Detection Method | Compensating Provisions | |||||||||||||||||||
| ID# | Function | Failure Mode Description | Failure Cause | Local Failure Effects | Next Higher Level Failure Effects | Major End Item Failure Effects | Safety | ||||||||||||||
| Consideration | Safety | ||||||||||||||||||||
| Impact | Operator Observation | Visual Indicator | C-Bit | ||||||||||||||||||
| Capabilities | Severity | ||||||||||||||||||||
| Classification | Alternate Design | ||||||||||||||||||||
| Modifications | Modified Severity | ||||||||||||||||||||
| Classification | β | βmod | α | λP | Cm | Mod Cm | |||||||||||||||
| 2203 | CONVERTS FIBER TO COPPER - FOR WIN-T RED DATA | Does not operate | Hardware failure or software defect | Loss of function | Loss of WIN-T Red Data | Degraded Mission due to loss of External Sensor Data | N/A | N/A | N/A | N/A | TBD | Category III | EOCs are Redundant | Category III | 0.05 | 0.05 | 0.5000 | 7.46E-07 | 1.34E-06 | 1.34E-06 | |
| 2204 | CONVERTS FIBER TO COPPER - FOR WIN-T RED DATA | Does not operate | Hardware failure or software defect | Loss of function | Loss of WIN-T Red Data | Degraded Mission due to loss of External Sensor Data | N/A | N/A | N/A | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.5000 | 7.46E-07 | 1.34E-05 | 1.34E-06 | |
| 2205 | CONVERTS FIBER TO COPPER - FOR WIN-T RED DATA | Intermittent | Hardware failure or software defect | Intermittent continuity | Probable Loss of WIN-T Red Data | Probable Degraded Mission due to loss of External Sensor Data | N/A | N/A | N/A | N/A | TBD | Category II | EOCs are Redundant | Category III-2R | 0.50 | 0.05 | 0.2500 | 7.46E-07 | 6.72E-06 | 6.72E-07 | |
| 2206 | CONVERTS FIBER TO COPPER - FOR WIN-T RED DATA | Degraded (Functional) | Hardware failure or software defect | Loss of noncritical function | Loss of noncritical function | Loss of noncritical function | N/A | N/A | N/A | N/A | TBD | Category IV | EOCs are Redundant | Category IV | 0.00 | 0.00 | 0.2500 | 7.46E-07 | 0.00E+00 | 0.00E+00 |
Sheet1
File details come from the government source that posted it. Updated .