Attachment 10c.16 – E069 Media Converter 03 - FMECA.xlsx

XLSX spreadsheet 35 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP
Solicitation number
W31P4Q-20-R-0015
Issued by

About this file

This document contains two parts: an attachment analyzing the failure modes and effects of a media converter component through a Failure Modes, Effects and Criticality Analysis (FMECA), and a draft Request for Proposal (RFP) for the Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production (LRIP/FRP) hardware segment.

The FMECA attachment analyzes four potential failure modes for a media converter component used in an E069 shelter: does not operate, intermittent operation, degraded functional operation, and no failures. It assigns severity classifications and calculates failure rates both with and without considering redundant emergency operation centers (EOCs).

The draft RFP seeks hardware production for IBCS, including maintaining approved software/firmware updates and authority to operate on existing hardware. Engineering changes may be required for obsolescence, new capabilities, and export considerations. The RFP is from the Department of the Army Materiel Command Contracting Command at Redstone Arsenal for an unspecified dollar value and period of performance. No response is currently being solicited as this is a draft for comment only.

View the file

Other files

File Type Posted
Attachment 10h - SWFMEA RESULTS.xlsx XLSX spreadsheet
Attachment 10a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.a - ALH-208670 05 IBCS SHELTER INTERCONNECT.pdf PDF
Attachment 22a - CASS to PDRS.docx DOCX document
Attachment 10c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 10a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.c - ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf PDF
Attachment 20 - Section M - Evaluation Factors For Award.docx DOCX document
Attachment 10a.15 – R033 Media Converter Module 12-FMECA.xlsx XLSX spreadsheet
Attachment 10c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 10a.2 – R002 BPU-FMECAAttachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10g - IBCS - 243-003 HW FMECA Results.pdf PDF
Attachment 22a.3 - S280_SystemPowerAnalysis_Draft_12-5-2017.xlsx XLSX spreadsheet
Attachment 10c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 10c.14 – E064 Shelter Router Black – FMECA.xlsx XLSX spreadsheet
Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA.xlsx XLSX spreadsheet
Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 10e.2 – E082 thru E091 Wkstn Laptop-FMECA.xlsx XLSX spreadsheet
Attachment 10d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 13c - IBCS-A301-003 Vol II Instructor Guide.pdf PDF
Attachment 03 - GFP Attachment - LRIP_FRP - 20 April 2020.xlsx XLSX spreadsheet
Attachment 10a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 22a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 19 - Section L - Instructions - Conditions - And Notices To Offerors.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.e - ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 04b - Draft_Relay Acceptance Test Procedures.docx DOCX document
Attachment 22a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 10c.6 – E051 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 10b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 16 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 13a -A293-004 ETM 60 Percent Draft.pdf PDF
Attachment 04a - Draft_EOC Acceptance Test Procedures.docx DOCX document
Attachment 10d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10e.1 – E067 – EtherNet Switch-FMECA.xlsx XLSX spreadsheet
Attachment 06 - Obsolete Parts List.pdf PDF
Attachment 04c - ECT_Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 15a- Example Skill Classification Crosswalk.xlsx XLSX spreadsheet
Attachment 10c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 10a.8 – R008 Media Converter Chassis-FMECA.xlsx XLSX spreadsheet
Attachment 10b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.b - ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 10c.1 – E043 Firewall Red-FMECA.xlsx XLSX spreadsheet
Show 40 more

Latest 50 of 98 listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

Row LabelsSum of CmCount of Failure Mode Description
Does not operate1.48E-052
Intermittent6.72E-061
Degraded (Functional)0.00E+001
Grand Total2.15E-054

Prelim Analysis

PRELIMINARY ANALYSIS:Major End Item:Shelter
Parent LRU:E069-Media Converter-03 ICE)
Component:MEDIA CONVERTOR, WIN-T A334
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =2.15E-05
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Does not operate250.0%Category II2Does not operate1.48E-052
Degraded (Functional)125.0%Does not operate1Intermittent6.72E-061
Intermittent125.0%Intermittent1Degraded (Functional)0.00E+001
Grand Total4Category III1Grand Total2.15E-054
Does not operate1
Category IV1
Degraded (Functional)1
Grand Total4

Cat I and II

Major End Item:Shelter
Parent LRU:E069-Media Converter-03 (ICE)
Component:MEDIA CONVERTOR, WIN-T A334
Mission Phase-Operational Mode:All Phases
FPMH:9.5583
t:72
Cr = ∑Cm =2.75E-04
Modified Cr =4.30E-05
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
2204CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.50009.56E-061.72E-041.72E-05
2205CONVERTS FIBER TO COPPER - FOR WIN-T RED DATAIntermittentHardware failure or software defectIntermittent continuityProbable Loss of WIN-T Red DataProbable Degraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.25009.56E-068.60E-058.60E-06

E069 Data

Major End Item:Shelter
Parent LRU:E069-Media Converter-03 (ICE)
Component:MEDIA CONVERTOR, WIN-T A334
Mission Phase-Operational Mode:All Phases
FPMH:0.7463
t:72
Cr = ∑Cm =2.15E-05
Modified Cr =3.36E-06
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety
ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
2203CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.050.50007.46E-071.34E-061.34E-06
2204CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.50007.46E-071.34E-051.34E-06
2205CONVERTS FIBER TO COPPER - FOR WIN-T RED DATAIntermittentHardware failure or software defectIntermittent continuityProbable Loss of WIN-T Red DataProbable Degraded Mission due to loss of External Sensor DataN/AN/AN/AN/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.25007.46E-076.72E-066.72E-07
2206CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADegraded (Functional)Hardware failure or software defectLoss of noncritical functionLoss of noncritical functionLoss of noncritical functionN/AN/AN/AN/ATBDCategory IVEOCs are RedundantCategory IV0.000.000.25007.46E-070.00E+000.00E+00

Sheet1

File details come from the government source that posted it. Updated .