Attachment 10d.4 – E151 – Media Converter 04-FMECA.xlsx

XLSX spreadsheet 35 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains a preliminary failure modes and effects analysis (FMECA) for an E151 media converter component used in a shelter for the WIN-T AXX system. The analysis identifies four potential failure modes: does not operate, intermittent operation, degraded functional operation, and no failure. Failure causes are listed as hardware or software issues. Effects are described at the component, next higher system, and overall shelter levels. Severity classifications are proposed and mitigation from redundant equipment carriers is noted. Compensating provisions like operator observation and visual indicators are identified. The related opportunity appears to be a draft request for proposal for low rate initial production and full rate production of Integrated Battle Command System hardware end items. The RFP seeks to produce hardware to technical data packages and specifications, and may require engineering changes for obsolescence, new capabilities, or export. No proposals are being sought from the draft posted.

View the file

Other files for this federal contract opportunity

Other files attached to DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
Attachment 22a.2 - PDRS Support information for integration task.pptx PPTX presentation
Attachment 15b - Fixed Price Level of Effort Labor Categories.xlsx XLSX spreadsheet
Attachment 10h - SWFMEA RESULTS.xlsx XLSX spreadsheet
Attachment 22a.1.h - PL-ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf PDF
Attachment 04c - ECT_Acceptance Test Procedures_FINAL.DOCX DOCX document
Attachment 22a.1.a - ALH-208670 05 IBCS SHELTER INTERCONNECT.pdf PDF
Attachment 10a.4 – R004 IGRM-FMECA.xlsx XLSX spreadsheet
Attachment 13 - Training Documentation.docx DOCX document
Attachment 10a.9 – R015 PDU Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10a.5 – R005 SCIM-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.j - PL-ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 10c.5 – E050 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 10b.9 – E033 R112 Shelter – Server Stack – 03-FMECA.xlsx XLSX spreadsheet
Attachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10a.13 – R031 Black Router--FMECA.xlsx XLSX spreadsheet
Attachment 10a.1 – R001 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 19 - Section L - Instructions - Conditions - And Notices To Offerors.docx DOCX document
Attachment 10c.8 – E053 Shelter Time Server-FMECA.xlsx XLSX spreadsheet
Attachment 10e.9 – E147 – Table 3 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.b - ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 10c.1 – E043 Firewall Red-FMECA.xlsx XLSX spreadsheet
Attachment 02 - AIAMD System of Systems (SoS)(MIS-PRF-56500).pdf PDF
Attachment 10b.1 – E001 28VDC Pwr Supply Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 10e.11 – E149 – Table 5 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA.xlsx XLSX spreadsheet
Attachment 12 - Risk Management Plan.pdf PDF
Attachment 04 - Acceptance Test Plan.docx DOCX document
Attachment 10c.13 – E063 Isolation Router Black-FMECA.xlsx XLSX spreadsheet
Attachment 10b.8 – E032 R112 Shelter – Server Stack – 02-FMECA.xlsx XLSX spreadsheet
Attachment 11- Cost Report and Plan.pdf PDF
Attachment 09 - R_M Predication Report.docx DOCX document
Attachment 10e.7 – E145 – Table 1 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 05 - Software Installation Instructions.docx DOCX document
Attachment 10a.10 – R016 thru R025 Media Converter Module-FMECA.xlsx XLSX spreadsheet
Attachment 10f - IBCS - 243-003 HW FMECA Results.docx DOCX document
Attachment 10e.3 – E092 thru E101 Wkstn Display-FMECA.xlsx XLSX spreadsheet
Attachment 10b.4 – E013 ADSI Shelter – Misc Equip-FMECA.xlsx XLSX spreadsheet
Attachment 10b.3 – E005 Blower Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 08 - AIAMD IUID Plan Appendix A - IUID Candidates List Data Items.pdf PDF
Attachment 10d.1 – E123 TMSS – ECU-FMECA.xlsx XLSX spreadsheet
Attachment 10c.11 – E061 Isolation Router Red-FMECA.xlsx XLSX spreadsheet
Attachment 10e.8 – E146 – Table 2 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10e.4 – E102d thru E111 Vid Extender-FMECA.xlsx XLSX spreadsheet
Attachment 01 - IBCS LRIP FRP Statement of Work.docx DOCX document
Attachment 10 - FMECA.docx DOCX document
Attachment 22a.1.c - ALH-211130 00 CABLE ASSEMBLY CASS DC POWER.pdf PDF
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 10a.16– R034 Media Converter Power Supply-FMECA.xlsx XLSX spreadsheet
W31P4Q-20-R-0015_DRAFT_28 May 2020.pdf PDF
Show all 50

DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Pivot Table

Row LabelsSum of CmCount of Failure Mode Description
Does not operate1.48E-052
Intermittent6.72E-061
Degraded (Functional)0.00E+001
Grand Total2.15E-054

Prelim Analysis

PRELIMINARY ANALYSIS:Major End Item:Shelter
Parent LRU:E151-Media Converter-04 (RED)
Component:MEDIA CONVERTOR, WIN-T AXX
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =2.15E-05
Failure ModesCount of
Failure ModesSeverity
ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Does not operate250.0%Category II2Does not operate1.48E-052
Degraded (Functional)125.0%Does not operate1Intermittent6.72E-061
Intermittent125.0%Intermittent1Degraded (Functional)0.00E+001
Grand Total4Category III1Grand Total2.15E-054
Does not operate1
Category IV1
Degraded (Functional)1
Grand Total4

Cat I and II

Major End Item:Shelter
Parent LRU:E151-Media Converter-04 (RED)
Component:MEDIA CONVERTOR, WIN-T AXX
Mission Phase-Operational Mode:All Phases
FPMH:9.5583
t:72
Cr = ∑Cm =2.75E-04
Modified Cr =4.30E-05
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
6339CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AOB-420-80N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.50009.56E-061.72E-041.72E-05
6340CONVERTS FIBER TO COPPER - FOR WIN-T RED DATAIntermittentHardware failure or software defectIntermittent continuityProbable Loss of WIN-T Red DataProbable Degraded Mission due to loss of External Sensor DataN/AN/AOB-420-80N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.25009.56E-068.60E-058.60E-06

Data E151

Major End Item:Shelter
Parent LRU:E151-Media Converter-04 (RED)
Component:MEDIA CONVERTOR, WIN-T AXX
Mission Phase-Operational Mode:All Phases
FPMH:0.7463
t:72
Cr = ∑Cm =2.15E-05
Modified Cr =3.36E-06
Due to the EOC Redundancy the Severity Classifications can be reduced Severity Classification III-2R
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
6338CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AOB-450-01VI-055-01 (Shelter PDP CB-18 Trips when Reset)TBDCategory IIIEOCs are RedundantCategory III0.050.050.50007.46E-071.34E-061.34E-06
6339CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADoes not operateHardware failure or software defectLoss of functionLoss of WIN-T Red DataDegraded Mission due to loss of External Sensor DataN/AN/AOB-420-80N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.50007.46E-071.34E-051.34E-06
6340CONVERTS FIBER TO COPPER - FOR WIN-T RED DATAIntermittentHardware failure or software defectIntermittent continuityProbable Loss of WIN-T Red DataProbable Degraded Mission due to loss of External Sensor DataN/AN/AOB-420-80N/ATBDCategory IIEOCs are RedundantCategory III-2R0.500.050.25007.46E-076.72E-066.72E-07
6341CONVERTS FIBER TO COPPER - FOR WIN-T RED DATADegraded (Functional)Hardware failure or software defectLoss of noncritical functionLoss of noncritical functionLoss of noncritical functionN/AN/AOB-420-80N/ATBDCategory IVEOCs are RedundantCategory IV0.000.000.25007.46E-070.00E+000.00E+00

Sheet1