Attachment 10d.2 – E144 RWS Bkup Batteries-FMECA.xlsx

XLSX spreadsheet 33 KB Posted

Attached to
DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP Federal contract opportunity
Solicitation number
W31P4Q-20-R-0015
Issued by
Department of the Army Materiel Command Contracting Command Redstone Arsenal

About this file

This document contains an FMECA (Failure Modes, Effects and Criticality Analysis) worksheet for backup batteries on an E144-RWS (Remote Weapon Station) shelter power system, as well as a draft RFP for the Integrated Battle Command System (IBCS) Low Rate Initial Production/Full Rate Production hardware segment.

The FMECA worksheet lists 21 potential failure modes for the backup batteries, including shorted, loose coupling, inoperable, mechanical failure, open and degraded output. It provides failure effect descriptions, detection methods, severity classifications and calculated failure rates. The draft RFP seeks hardware production for the IBCS, including maintaining approved software/firmware updates, cybersecurity and authority to operate on existing hardware. It would produce IBCS hardware end items per supplied technical data packages and critical item development specification. Engineering changes may be required for obsolescence, new capabilities or export considerations. The solicitation number is W31P4Q-20-R-0015 and it is issued by the Department of the Army Materiel Command Contracting Command Redstone Arsenal.

View the file

Other files for this federal contract opportunity

Other files attached to DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP, newest first.
File Type Posted
Attachment 10d.8 – E153 RS112 Server -07 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 15a- Example Skill Classification Crosswalk.xlsx XLSX spreadsheet
Attachment 16 - Example Cage Code and Cognizant DCMA DCAA Information.xlsx XLSX spreadsheet
Attachment 10a.11 – R029 PFPU SSHD-1—FMECA.xlsx XLSX spreadsheet
Attachment 10c.2 – E044 Firewall Black-FMECA.xlsx XLSX spreadsheet
Attachment 13d - IBCS-A301-003 Vol III Program of Instruction.pdf PDF
Attachment 10g - IBCS - 243-003 HW FMECA Results.pdf PDF
Attachment 10d.9 – E156 UPS-FMECA.xlsx XLSX spreadsheet
Attachment 10d.6 – E153 RS112 Server -05 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10b.10 – E034 R112 Shelter – Server Stack – 04-FMECA.xlsx XLSX spreadsheet
Attachment 10e.1 – E067 – EtherNet Switch-FMECA.xlsx XLSX spreadsheet
Attachment 10d.4 – E151 – Media Converter 04-FMECA.xlsx XLSX spreadsheet
Attachment 10c.3 – E048 HRFU-FMECA.xlsx XLSX spreadsheet
Attachment 10b.7 – E031 R112 Shelter – Server Stack – 01-FEMCA.xlsx XLSX spreadsheet
Attachment 22a.3 - S280_SystemPowerAnalysis_Draft_12-5-2017.xlsx XLSX spreadsheet
Attachment 10c.16 – E069 Media Converter 03 - FMECA.xlsx XLSX spreadsheet
Attachment 10b.6 – E030 KVM Console-FMECA.xlsx XLSX spreadsheet
Attachment 13a -A293-004 ETM 60 Percent Draft.pdf PDF
Attachment 10d.10 – E157 KVM Switch 2 Shelter-FMECA.xlsx XLSX spreadsheet
Attachment 10c.12 – E062 Shelter Router-Red-FMECA.xlsx XLSX spreadsheet
Attachment 14 - Technical Library.docx DOCX document
Attachment 10e.2 – E082 thru E091 Wkstn Laptop-FMECA.xlsx XLSX spreadsheet
Attachment 10c.14 – E064 Shelter Router Black – FMECA.xlsx XLSX spreadsheet
Attachment 10c.9 – E059 Shelter Switch – 01-FMECA.xlsx XLSX spreadsheet
Attachment 22a.1.i - PL-ALH-213030 00 CABLE ASSEMBLY, CASS J1 AND J3.pdf PDF
Attachment 10a.8 – R008 Media Converter Chassis-FMECA.xlsx XLSX spreadsheet
Attachment 10e.6 – E143 – ICE UPS-FMECA.xlsx XLSX spreadsheet
Attachment 07 - AIAMD Requirements Prioritization 1-n table.docx DOCX document
Attachment 10a.2 – R002 BPU-FMECAAttachment 10b.2 – E002 Power Inverter Shelter Power-FMECA.xlsx XLSX spreadsheet
Attachment 06 - Obsolete Parts List.pdf PDF
Attachment 04a - Draft_EOC Acceptance Test Procedures.docx DOCX document
Attachment 21 - Task Order 0001 Statement of Work.docx DOCX document
Attachment 10c.10 – E060 Shelter Switch – 02-FMECA.xlsx XLSX spreadsheet
Attachment 10a.16– R034 Media Converter Power Supply-FMECA.xlsx XLSX spreadsheet
W31P4Q-20-R-0015_DRAFT_28 May 2020.pdf PDF
Attachment 10a.3 – R003 KG-250X-FMECA.xlsx XLSX spreadsheet
Attachment 04b - Draft_Relay Acceptance Test Procedures.docx DOCX document
Attachment 13c - IBCS-A301-003 Vol II Instructor Guide.pdf PDF
Attachment 22a.1.f - EOC Shelter views.pptx PPTX presentation
Attachment 22a.1.d - ALH-213030 00 CABLE ASSEMBLY, CASS J1 AND J3.pdf PDF
Attachment 10a.14 – R032 Media Converter Module 11-FMECA.xlsx XLSX spreadsheet
Attachment 20 - Section M - Evaluation Factors For Award.docx DOCX document
Attachment 22a - CASS to PDRS.docx DOCX document
Attachment 10d.7 – E153 RS112 Server -06 Shelter with PT-FMECA.xlsx XLSX spreadsheet
Attachment 10e.10 – E148 – Table 4 Assembly-FMECA.xlsx XLSX spreadsheet
Attachment 10e.5 – E122 – EMI Tent PDU-FMECA.xlsx XLSX spreadsheet
Attachment 17 - Pre-Award Survey Accounting System Checklist.pdf PDF
Attachment 22a.1.g - PL-ALH-209032 00 CABLE ASSEMBLY CASS ETHERNET.pdf PDF
Attachment 22a.1.e - ALH-215333 00 S-280 CASS INSTALLATION.PDF PDF
Attachment 22a.4 - CASS Task Purpose.pptx PPTX presentation
Show all 50

DRAFT RFP for Integrated Battle Command System (IBCS) LRIP/FRP has more files on GovTribe.

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet2

Row LabelsSum of CmCount of Failure Mode Description
Shorted8.54E-064
Loose Coupling4.80E-063
Inoperable4.80E-063
Mechanical Failure4.80E-063
Open4.80E-063
Mechanical Damage4.80E-063
Degraded Output5.34E-071
Intermittent Output5.34E-071
Grand Total3.36E-0521

Prelim Analysis

Major End Item:Shelter - Power
Preliminary AnalysisParent LRU:E144-RWS Backup Batteries
Compoment:BACKUP BATTERIES
Mission Phase-Operational Mode:All Phases
Cr = ∑Cm =3.36E-05
Failure ModesCount of
Failure ModesSeverity ClassificationsCount of

Seveverity Classification Failure Modes Sum of Cm Count of Failure Modes

Shorted419.05%Category III21Shorted0.00000853844
Loose Coupling314.29%Shorted4Loose Coupling0.00000480283
Inoperable314.29%Loose Coupling3Inoperable0.00000480283
Mechanical Failure314.29%Inoperable3Mechanical Failure0.00000480283
Open314.29%Mechanical Failure3Open0.00000480283
Mechanical Damage314.29%Open3Mechanical Damage0.00000480283
Degraded Output14.76%Mechanical Damage3Degraded Output0.00000053361
Intermittent Output14.76%Degraded Output1Intermittent Output0.00000053361
Grand Total21Intermittent Output1Grand Total0.000033619821
Grand Total21

Cat I and II No Category I and Category II Classifications

Data

MEI:Shelter -Power
Parent LRU:E144-RWS Backup Batteries
Compoment:BACKUP BATTERIES
Mission Phase-Operational Mode:All Phases
FPMH:3.113
t:72hr
Cr = ∑Cm =3.36E-05
Modified Cr =3.36E-05
No Category I and Category II Classifications
Failure Effect atFailure Detection MethodCompensating Provisions
ID#FunctionFailure Mode DescriptionFailure CauseLocal Failure EffectsNext Higher Level Failure EffectsMajor End Item Failure EffectsSafety
ConsiderationSafety ImpactOperator ObservationVisual IndicatorC-Bit
CapabilitiesSeveverity
ClassificationAlternate Design
ModificationsModified Severity
ClassificationββmodαλPCmMod Cm
4682Backup Batteries - Modeled As A Group Of 2 (Should Be Replaced As A Group). MTBF Is For Random Failure And Not Wear Out.Degraded OutputHardware FailureDegraded Battery OutputDegraded battery backup systemDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.054.76E-023.11E-065.34E-075.34E-07
4683Backup Batteries - Modeled As A Group Of 2 (Should Be Replaced As A Group). MTBF Is For Random Failure And Not Wear Out.ShortedHardware FailureLarge current surge resulting in downstream fuse F1 blowDegraded battery backup systemDegraded battery backup system for a Single EOCN/AN/AOB-001-01N/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.90E-013.11E-062.13E-062.13E-06
4684Backup Batteries - Modeled As A Group Of 2 (Should Be Replaced As A Group). MTBF Is For Random Failure And Not Wear Out.Intermittent OutputHardware FailureDegraded Battery OutputDegraded battery backup systemDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.054.76E-023.11E-065.34E-075.34E-07
4685Battery Terminal NegativeOpenHardware FailureLoss of electrical connectivityLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4686Battery Terminal NegativeMechanical DamageHardware FailurePossible loss of electrical connectivityPossible Loss of RWS Backup BatteriesPossible Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4687Battery Terminal NegativeInoperableHardware FailureProbable loss of electrical connectivityProbable Loss of RWS Backup BatteriesProbable Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4688Battery Terminal NegativeLoose CouplingHardware FailureProbable loss of electrical connectivityProbable Loss of RWS Backup BatteriesProbable Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4689Battery Terminal NegativeMechanical FailureHardware FailureLoss of electrical connectivityLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4690Battery Terminal NegativeSHORTEDHardware FailureShort to case resulting in loss of electrical connectivityLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.90E-013.11E-062.13E-062.13E-06
4691Battery Terminal PositiveOpenHardware FailureLoss of electrical connectivityLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4692Battery Terminal PositiveMechanical DamageHardware FailurePossible loss of electrical connectivityPossible Loss of RWS Backup BatteriesPossible Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4693Battery Terminal PositiveInoperableHardware FailureProbable loss of electrical connectivityProbable Loss of RWS Backup BatteriesProbable Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4694Battery Terminal PositiveLoose CouplingHardware FailureProbable loss of electrical connectivityProbable Loss of RWS Backup BatteriesProbable Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4695Battery Terminal PositiveMechanical FailureHardware FailureLoss of electrical connectivityLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4696Battery Terminal PositiveSHORTEDHardware FailureShort to case resulting in possible F1 Fuse blowLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AOB-001-01N/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.90E-013.11E-062.13E-062.13E-06
4697CA connecting RWS Backup Batteries in seriesOpenHardware FailureLoss of electrical connectivityLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4698CA connecting RWS Backup Batteries in seriesMechanical DamageHardware FailurePossible loss of electrical connectivityPossible Loss of RWS Backup BatteriesPossible Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4699CA connecting RWS Backup Batteries in seriesInoperableHardware FailureProbable loss of electrical connectivityProbable Loss of RWS Backup BatteriesProbable Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4700CA connecting RWS Backup Batteries in seriesLoose CouplingHardware FailureProbable loss of electrical connectivityProbable Loss of RWS Backup BatteriesProbable Degraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4701CA connecting RWS Backup Batteries in seriesMechanical FailureHardware FailureLoss of electrical connectivityLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.43E-013.11E-061.60E-061.60E-06
4702CA connecting RWS Backup Batteries in seriesSHORTEDHardware FailureShort to case resulting in loss of electrical connectivityLoss of RWS Backup BatteriesDegraded battery backup systemN/AN/AN/AN/ATBDCategory IIIEOCs are RedundantCategory III0.050.051.90E-013.11E-062.13E-062.13E-06